HomeMy WebLinkAboutProduct Approval (2) 398 East Dania Beach Blvd.
BUILDING DROPS Suite 338
Dania Beach, FL 33004
A Perfect Solution in Every Drop 954.399.8478 PH
Certificate of Authorization:29578 954.744.4738 FX
contact@buildingdrops.com
Prodlact Evaluation Report
Of
JELD-WEN, inc..
Contours Steel Door, Wood Edge
24 Ga. Opaque Door & Glazed Sidelite
Up to 8'-4" x 8'-0"
Outswing/Inswing
for
Florida Product Approval
Report . 3322
Current Florida Building Code
Method: 1 — A (Certification)
Category: Exterior Doors
Sub —Category: Swinging Exterior Door Assemblies
Product: Contours Steel Door, Wood Edge
24 Ga. Opaque Door& Glazed Sidelite
Up to 8 W"x 8'-0"Outswing/Inswilig
Material: Steel/Wood
Product Dimensions: 105"X 97.875"(Maximum)
Prepared For:
JELD- jEN, ine.
3737 Lakeport Blvd.
lannath Falls, Off.. 97601 ```. ��5 F.., 0�
l
. O
:Prepared by: = 7
Hermes mes F. Norero, P.E.PE _ � .
� ~a TT � Z
Florida Professional Engineer#73778 t,
Date: 11/11/2014 0,�' L ..•.DP;: \=w`�:
O
Contents: 'j s/ONA;
Evaluation Report Pages 1 —4 I I 1 t
Digitally signed by Hermes F.Norero,P.E. Hermes F. Norero, P.E.
Reason:I am approving this document Florida No.73778
Date:2015.01.0715:15:40-05'00'
BUILDING DROPS
A Perfect Solution in Every Drop Date: 11/11/2014
Report No: 3322
Certificate of Authorization:29578
Manufacturer: JELD-WEN,Inc.
Product Category: Exterior Doors
Product Sub-Category: Swinging Exterior Door Assemblies
Compliance Method: State Product Approval Method (1)(a)
Product Name: Contours Steel Door,Wood Edge 24 Ga.Opaque Door&Glazed Sidelite
Up to 8'4"x 8'-0"Outswing/Inswing
105"X 97.875"(Maximum)
Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL#73778)for JELD-WEN inc.
based on Method 1a of the State of Florida Product Approval, Florida Department of Business and
Professional Regulation- Florida Building Commission.
Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company
manufacturing or distributing the product or in any other entity involved in the approval process of
the product named herein.
This product has been evaluated for use in locations adhering to the current Florida Building Code.
See Installation Instructions JW072012FL,signed and sealed by Hermes F. Norero, P.E. (FL#73778)
for specific use parameters.
Limits of Use:
1. This product has been evaluated and is in compliance with the current Florida Building Code,
including the"High Velocity Hurricane Zone" (HVHZ).
2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into
substrate material shall be beyond wall dressing or stucco.
3. When used in areas requiring wind borne debris protection this product complies with
Section 1609.1.2 of the current Florida Building Code and does not require an impact
resistant covering.
4. Non-Impact sidelites do require an impact resistant covering when used in areas requiring
wind borne debris protection to comply with Section 1609.1.2 of the current Florida Building
Code.
5. Site conditions that deviate from the details of drawing JW072012FL require further
engineering analysis by a licensed engineer or registered architect.
6. See Installation Instructions JW072012FL for size and design pressure limitations.
Hermes F. Norero,P.E.
Florida No.73778
Page 2 of 4
BUILDING DROPS
Date: 11/11/2014
A Perfect Solution in Every Drop Report No: 3322
Certificate of Authorization:29578
Quality Assurance: The manufacturer has demonstrated compliance of products in accordance with the
Florida Building Code for manufacturing under a quality assurance program audited
by an approved quality assurance entity through National Accreditation&
Management Institute,Inc. (FBC Organization#QUA1789).
Performance Standards: The product described herein has been tested per:
• TAS 201-94
• TAS 202-94
• TAS 203-94
Referenced Data:
1. Product Testing performed by National Certified Testing Laboratory,Inc.
(FBC Organization# TST1589)
Report#: NCTL-210-3801-1, Report Date:02/03/2012
Product Testing performed by Architectural Testing,Inc.
(FBC Organization#TST1910)
Report#: 65888.01-301-18, Report Date:08/21/2006
Report#:75771.01-301-18, Report Date: 11/01/2007
Product Testing performed by Certified Testing Laboratories,Inc.
(FBC Organization#TST1577)
Report#:CTLA 697WA, Report Date: 11/12/2001
2. Quality Assurance
National Accreditation and Management Institute
(FBC Organization#QUA1789)
3. Material Certification
Miami-Dade RER Product Control Section NOA
Eastman Chemical Company Saflex Clear and Color Glass Interlayer
4. Material Certification
Miami-Dade RER Product Control Section NOA
ODL Series"HP Polypropylene"White Material Component Approval
Hermes F. Norero,P.E.
Florida No.73778
Page.3 of 4
BUILDING DROPS
A Perfect Solution in Every Drop Date: 11/11/2014Report No: 3322
Certificate of Authorization:29578
Installation: 1. Approved anchor types and substrates areas follows:
Through Frame Installation:
A. For two by(2X)wood buck substrate, use#10 Wood Screw type installation anchors of
sufficient length to achieve a minimum embedment of 1.50"into the wood substrate.
E B.B. For concrete or masonry substrate where one by(1X), non-structural,wood bucking is
employed, use 3/16"diameter ITW Tapcon type concrete screw anchors of sufficient
B.
to achieve minimum embedment of 1.25" into concrete or masonry.
C. For concrete or masonry substrate where wood bucking is NOT employed,use 3/16"
diameter ITW Tapcon type concrete screw anchors of sufficient length to achieve
minimum embedment of 1.25"into concrete or masonry.
Refer to Installation Instructions(JW072012FL)for anchor spacing and more details of the
installation requirements.
Design Pressure:
Design Pressure
ALL UNITS
Outswing
Positive 45 PSF*
Negative 45 PSF
Positive 45 PSF*
Inswing Negative 45 PSF
diction
requires that product meets this requirement, product shall be used when
installed at location protected by overhang such that overhang(OH) ratio=OH
length/OH height is 1.0.
Hermes F. Norero, P.E.
Florida No. 73778
Page 4 of 4