Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Florida Gas Transmission (2 of 2) 94-00651
`a y i I r ,rYs?�5ws 1 ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY PROJECT NUMBER: S22138 MATERIALS LIST PROJECT NAME: FGT - STATION #20 CTR MARK REQUEST QUANTITY UNIT NO. PURCHAS FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRA * E-0002 A/R FT CONDUIT -RIGID GALVANIZED STEEL, 3/4" 238-01 ITEM NUMBER - 33-016-0102 REQUEST NUMBER * E-0003 A/R FT CONDUIT -RIGID -GALVANIZED STEEL, 1" 238-01 ITEM NUMBER - 33-016-0008 REQUEST NUMBER * E-0005 A/R FT CONDUIT -RIGID GALVANIZED STEEL, 1-1/2" 238-01 ITEM NUMBER - 33-016-0104 REQUEST NUMBER * E-0006 A/R FT. CONDUIT -RIGID GALVANIZED STEEL, 2" 238-01 ITEM NUMBER - 33-016-0009 REQUEST NUMBER * E-0008 A/R FT. CONDUIT -RIGID GALVANIZED STEEL, 3" 238-01 i ITEM NUMBER - 33-016-0010 REQUEST NUMBER - * E-0009 A/R FT. CONDUIT -RIGID GALVANIZED STEEL, 4" 238-01 ITEM NUMBER - 33-016-0011 REQUEST NUMBER - * E-0012 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, 238-01 COUPLING, 3/4" DIA, MANUFACTURER STD, FEMALE BY FEMALE THREADS ITEM NUMBER - 33-020-0062 REQUEST NUMBER - * E-0013 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, 238-01 COUPLING, 1" DIA, MANUFACTURER STD, FEMALE BY FEMALE THREADS ITEM NUMBER - 33-020-0063 REQUEST NUMBER - * E-0015 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, 238-01 COUPLING, 1-1/2" DIA, MANUFACTURER STD, FEMALE BY FEMALE THREADS ITEM NUMBER - 33-020-0065 REQUEST NUMBER - * E-0016 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, 238-01 COUPLING, 2" DIA, MANUFACTURER STD, FEMALE BY FEMALE THREADS ITEM NUMBER 33-020-0066 REQUEST NUMBER .xre i ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 2 OF 73 CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0016 AIR EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, 238-01 COUPLING, 3" DIA, MANUFACTURER STD, FEMALE BY FEMALE THREADS ITEM NUMBER - 33-020-0068 REQUEST NUMBER * E-0018 AIR EA, CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, 238-01 COUPLING, 4" DIA, MANUFACTURER STD, FEMALE BY FEMALE THREADS ITEM NUMBER - 33-020-0070 REQUEST NUMBER - * E-0023 AIR EA, CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, ELBOW, 238-01 90 DEG TYPE, 3/4" DIA, MANUFACTURER STD, MALE BY MALE THREADS ITEM NUMBER - 33-020-0038 REQUEST NUMBER * E-0024 AIR EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, ELBOW, 238-01 90 DEG TYPE, 1" DIA, MANUFACTURER STD, MALE BY MALE THREADS ITEM NUMBER - 33-020-0039 REQUEST NUMBER - * E-0025 AIR EA CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, ELBOW, 238-01 90 DEG TYPE, 1-1/2" DIA, MANUFACTURER STD, MALE BY MALE THREADS ITEM NUMBER - 33-020-0041 REQUEST NUMBER - * E-0027 AIR EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, ELBOW, 238-01 90 DEG TYPE, 2" DIA, MANUFACTURER STD, MALE BY MALE THREADS ITEM NUMBER - 33-020-0042 REQUEST NUMBER - * E-0028 AIR EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, ELBOW, 238-01 90 DEG TYPE, 3" DIA, MANUFACTURER STD, MALE BY MALE THREADS ITEM NUMBER - 33-020-0044 REQUEST NUMBER - * E-0029 AIR EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, ELBOW, 238-01 90 DEG TYPE, 4" DIA, MANUFACTURER STD, MALE BY MALE THREADS ITEM NUMBER - 33-020-0046 REQUEST NUMBER ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: 522138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 3 OF 73 CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0042 A/R FT. CONDUIT -PVC COATED RIGID GALVANIZED STEEL, 3/4" 238-01 ITEM NUMBER - 33-016-0101 REQUEST NUMBER - NOTES: PLASTI-BOND RED * E-0043 A/R FT. CONDUIT -PVC COATED RIGID GALVANIZED STEEL, 1" 238-01 ITEM NUMBER - 33-016-0002 REQUEST NUMBER - NOTES: PLASTI-BOND RED * E-0045 A/R FT. CONDUIT -PVC COATED RIGID GALVANIZED STEEL, 1-1/2" 238-01 ITEM NUMBER - 33-016-0003 REQUEST NUMBER - NOTES: PLASTI-BOND RED * E-0046 A/R FT. CONDUIT -PVC COATED RIGID GALVANIZED STEEL, 2" 238-01 ITEM NUMBER - 33-016-0004 REQUEST NUMBER - NOTES: PLASTI-BOND RED * E-0048 A/R FT. CONDUIT -PVC COATED RIGID GALVANIZED STEEL, 3" 238-01 ITEM NUMBER - 33-016-0005 REQUEST NUMBER - NOTES: PLASTI-BOND RED * E-0049 A/R FT. CONDUIT -PVC COATED RIGID GALVANIZED STEEL, 4" 238-01 ITEM NUMBER - 33-016-0006 REQUEST NUMBER - NOTES: PLASTI-BOND RED * E-0052 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, 238-01 COUPLING, 3/4" DIA, MANUFACTURER STD, FEMALE BY FEMALE THREADS, WITH PVC COATING ITEM NUMBER - REQUEST NUMBER NOTES: PLASTI-BOND RED * E-0053 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, 238-01 COUPLING, 1" DIA, MANUFACTURER STD, FEMALE BY FEMALE THREADS, WITH PVC COATING ITEM NUMBER - REQUEST NUMBER NOTES: PLASTI- BOND RED DESIGN FLORIDAGAS TRANSMISSION COMPANY RUN DATE: 12/03/93 :ENGPINERING NUMBER: 522138 MATERIALS LIST - RUN TIME: 16:41:32 NAME: FGT - STATION #20 PAGE 4 OF 73CTRRK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FURBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0055 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, 238-01 COUPLING, 1-1/2" DIA, MANUFACTURER STD, FEMALE BY FEMALE THREADS, WITH PVC COATING ITEM NUMBER - REQUEST NUMBER - NOTES: PLASTI-BOND RED * E-0056 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, 238-01 COUPLING, 2" DIA, MANUFACTURER STD, FEMALE BY FEMALE THREADS, WITH PVC COATING ITEM NUMBER - REQUEST NUMBER NOTES: PLASTI-BOND RED * E- 058 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, 238-01 COUPLING, 3" DIA, MANUFACTURER STD, FEMALE BY FEMALE THREADS, WITH PVC COATING ITEM NUMBER - REQUEST NUMBER NOTES: PLASTI-BOND RED * E 059 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, 238-01 COUPLING, 4" DIA, MANUFACTURER STD, FEMALE BY FEMALE THREADS, WITH PVC COATING ITEM NUMBER - REQUEST NUMBER NOTES: PLASTI-BOND RED * E-6063 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, ELBOW, 238-01 EL- 90 DEG TYPE, 1" DIA, MANUFACTURER STD, MALE BY MALE THREADS, WITH PVC COATING ITEM NUMBER - REQUEST NUMBER NOTES: PLASTI-BOND RED * E-0065- A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, ELBOW, 238-01 EL- 90 DEG TYPE, 1-1/2" DIA, MANUFACTURER STD, MALE BY MALE THREADS, WITH PVC COATING ' o` ITEM NUMBER REQUEST NUMBER / NOTES: 4}' PLASTI-BOND RED )m 1'� ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: 522138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT STATION #20 PAGE 5 OF 73 CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0066 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, ELBOW, 238-01 EL- 90 DEG TYPE, 2" DIA, MANUFACTURER STD, MALE BY MALE THREADS, WITH PVC COATING ITEM NUMBER - REQUEST NUMBER - NOTES: PLASTI-BOND RED * E-0068 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, ELBOW, 238-01 EL- 90 DEG TYPE, 3" DIA, MANUFACTURER STD, MALE BY MALE THREADS, WITH PVC COATING ITEM NUMBER - REQUEST NUMBER NOTES: PLASTI-BOND RED * E-0069 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, ELBOW, 238-01 EL- 90 DEG TYPE, 4" DIA, MANUFACTURER STD, MALE BY MALE THREADS, WITH PVC COATING ITEM NUMBER - 33-020-0574 REQUEST NUMBER NOTES: PLASTI-BOND RED * E-0075 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, ELBOW, 238-01 EL- 45 DEG TYPE, 1-1/2" DIA, MANUFACTURER STD, MALE BY MALE THREADS, WITH PVC COATING ITEM NUMBER - REQUEST NUMBER NOTES: PLASTI-BOND RED * E-0076 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, ELBOW, 238-01 EL- 45 DEG TYPE, 2" DIA, MANUFACTURER STD, MALE BY MALE THREADS, WITH PVC COATING ITEM NUMBER - REQUEST NUMBER - NOTES: PLASTI-BOND RED * E-0082 A/R FT. CONDUIT -ELECTRICAL METALLIC TUBING, 3/4" 238-01 ITEM NUMBER - 33-016-0105 REQUEST NUMBER - * E-0083 A/R FT. CONDUIT -ELECTRICAL METALLIC TUBING, 1" 238-01 ITEM NUMBER - 33-016-0031 REQUEST NUMBER - ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 6 OF 73 CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0088 A/R EA. CONDUIT FITTING -FOR ELECTRICAL METALLIC TUBING, 238-01 CONNECTOR, 3/4" DIA, METALLIC, COMPRESSION BY MALE THREADS ITEM NUMBER - REQUEST NUMBER NOTES: SPECIFICATION GRADE * E-0089 A/R EA. CONDUIT FITTING -FOR ELECTRICAL METALLIC TUBING, 238-01 CONNECTOR, 1" DIA, METALLIC, COMPRESSION BY MALE THREADS ITEM NUMBER - REQUEST NUMBER NOTES: SPECIFICATION GRADE * E-0092 A/R EA. CONDUIT FITTING -FOR ELECTRICAL METALLIC TUBING, 238-01 COUPLING, 3/4" DIA, METALLIC, COMPRESSION BY COMPRESSION ITEM NUMBER - REQUEST NUMBER NOTES: SPECIFICATION GRADE * E 0093 A/R EA. CONDUIT FITTING -FOR ELECTRICAL METALLIC TUBING, 238-01 COUPLING, 1" DIA, METALLIC, COMPRESSION BY COMPRESSION ITEM NUMBER - REQUEST NUINBER NOTES: SPECIFICATION GRADE * E-0101 A/R FT. CONDUIT -SCHEDULE 80 PVC PLASTIC, 1" 238-01 ITEM NUMBER - 33-016-0023 REQUEST NUMBER - * E-0102 A/R FT. CONDUIT -SCHEDULE 80 PVC PLASTIC, 1-1/2" 238-01 ITEM NUMBER - 33-016-0024 REQUEST NUMBER - * E-0103 A/R FT. CONDUIT -SCHEDULE 80 PVC PLASTIC, 2" 238-01 ITEM NUMBER - 33-016-0025 REQUEST NUMBER - * E-0104 A/R FT. CONDUIT -SCHEDULE 80 PVC PLASTIC, 3" 238-01 ITEM NUMBER - 33-016-0026 REQUEST NUMBER - * E-0105 A/R FT. CONDUIT -SCHEDULE 80 PVC PLASTIC, 4" 238-01 ITEM NUMBER - 33-016-0027 REQUEST NUMBER - ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 7 OF 73 CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E 0110 A/R EA. CONDUIT FITTING -FOR SCHEDULE 80 PVC PLASTIC, ELBOW, 238-01 90 DEG TYPE, 1" DIA, PLASTIC ITEM NUMBER - 33-020-0573 REQUEST NUMBER - * E 0111 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, UNION, 238-01 UNF TYPE, 112" DIA, MANUFACTURER STD, FEMALE BY FEMALE THREADS ITEM NUMBER - 33-020-0308 REQUEST NUMBER - * E 0112 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, UNION, 238-01 UNF TYPE, 3/4" DIA, MANUFACTURER STD, FEMALE BY FEMALE THREADS ITEM NUMBER- 33-020-0309 REQUEST NUMBER - * E 0113 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, UNION, 238-01 UNF TYPE, 1" DIA, MANUFACTURER STD, FEMALE BY FEMALE THREADS ITEM NUMBER - 33-020-0310 REQUEST NUMBER * E-0115 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, UNION, 238-01 UNF TYPE, 1-1/2" DIA, FERALOY, FEMALE BY FEMALE THREADS ITEM NUMBER - REQUEST NUMBER * E-0116 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, UNION, 238-01 UNF TYPE, 2" DIA, FERALOY, FEMALE BY FEMALE THREADS ITEM NUMBER - REQUEST NUMBER - * E-0117 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, UNION, 238-01 UNF TYPE, 3" DIA, FERALOY, FEMALE BY FEMALE THREADS, NON -INSULATED ITEM NUMBER - REQUEST NUMBER - * E-0118 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, UNION, 238-01 UNF TYPE, 4" DIA, FERALOY, FEMALE BY FEMALE THREADS ITEM NUMBER - REQUEST NUMBER - * E 0119 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, UNION, 238-01 d 3/41' DIA, MALLEABLE IRON, INSULATED w ITEM NUMBER - 33-020-0576 REQUEST NUMBER % NOTES:" DIELECTRIC UNION WITH GROUND JOINT AND NYLON RETURN. 0f CENTRAL PLASTICS CO. P/N 100-757500-010. ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 8 OF 73 . CTR MARK REQUEST QUANTITY UNIT NO, PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0120 AIR EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, UNION, 238-01 1" DIA, MALLEABLE IRON, INSULATED ITEM NUMBER - 33-020-0577 REQUEST NUMBER - NOTES: DIELECTRIC UNION WITH GROUND JOINT AND NYLON RETURN. CENTRAL PLASTICS CO. P/N 100-1010500-010. * E-0121 AIR EA. CONDUIT SEAL -FITTING WITH DRAIN, 1/211, FEMALE 238-01 THREADS ITEM NUMBER - 33-022-0064 REQUEST NUMBER NOTES: C-H CAT.# EYD11 * E-0122 AIR EA. CONDUIT SEAL -FITTING WITH DRAIN, 3/411, FEMALE 238-01 THREADS ITEM NUMBER - 33-022-0066 REQUEST NUMBER - NOTES: C-H CAT.# EYD21 * E-0123 AIR EA. CONDUIT SEAL -FITTING WITH DRAIN, 1", FEMALE THREADS 238-01 ITEM NUMBER - 33-022-0072 REQUEST NUMBER - NOTES: C-H CAT.# EYD31 * E-0125 AIR EA. CONDUIT SEAL -FITTING WITH DRAIN, 1-11211, FEMALE 38-01 THREADS ITEM NUMBER - 33-022-0068 REQUEST NUMBER NOTES: C-H CAT.# EYD51 * E-0126 AIR EA. CONDUIT SEAL -FITTING WITH DRAIN, 211, FEMALE THREADS 238-01 ITEM NUMBER - 33-022-0076 REQUEST NUMBER NOTES: C-H CAT.# EYD61 * E-0127 AIR EA. CONDUIT SEAL -FITTING WITH DRAIN, 311, MALE X FEMALE 238-01 THREADS ITEM NUMBER - 33-022-0083 REQUEST NUMBER' NOTES: 1 �� C-H CAT# EYD86 a ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: 522138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 9 OF 73 CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0142 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, HUB, 238-01 STRAIGHT TYPE, 3/4" DIA, FERALOY, FEMALE BY FEMALE THREADS, INSULATED ITEM NUMBER - REQUEST NUMBER NOTES: C-H CAT.# NUB-2 * E-0143 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, HUB, 238-01 STRAIGHT TYPE, 1" DIA, FERALOY, FEMALE BY FEMALE THREADS, INSULATED ITEM NUMBER - REQUEST NUMBER - NOTES: C-H CAT.# HUB-3 * E-0145 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, HUB, 238-01 1-1/2" DIA, MANUFACTURER STD, FEMALE BY FEMALE THREADS ITEM NUMBER REQUEST NUMBER NOTES: C-H CAT.# HUB-5 * E-0146 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, HUB, 2" 238-01 DIA, MANUFACTURER STD, FEMALE BY FEMALE THREADS ITEM NUMBER - REQUEST NUMBER NOTES: C-H CAT.# HUB-6 * E-0148 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, HUB, 3" 238-01 DIA, MANUFACTURER STD, FEMALE BY FEMALE THREADS ITEM NUMBER - REQUEST NUMBER - NOTES: C-H CAT.# HUB-8 * E-0149 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, HUB, 4" 238-01 DIA, MANUFACTURER STD, FEMALE BY FEMALE THREADS ITEM NUMBER - 33-020-0575 REQUEST NUMBER - NOTES: C-H CAT.# HUB-10 * E-0151 A/R EA. CONDUIT NIPPLE -FOR RIGID GALVANIZED STEEL, 1/2" DIA, 238-01 CLOSE ITEM NUMBER - REQUEST NUMBER - ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 10 OF 73 CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME-SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0152 A/R EA. CONDUIT NIPPLE -FOR RIGID GALVANIZED STEEL, 3/4" DIA, 238-01 CLOSE ITEM NUMBER - REQUEST NUMBER - * E-0153 A/R EA. CONDUIT NIPPLE -FOR RIG;1!D GALVANIZED STEEL, 1" DIA, 238-01 CLOSE ITEM NUMBER - REQUEST NUMBER - * E-0155 A/R EA. CONDUIT NIPPLE -FOR RIGID GALVANIZED STEEL, 1-1/2" 238-01 DIA, CLOSE ITEM NUMBER - REQUEST NUMBER - * E-0156 A/R EA. CONDUIT NIPPLE -FOR RIG 1ID GALVANIZED STEEL, 2" DIA, 238-01 CLOSE ITEM NUMBER - REQUEST NUMBER - * E-0158 A/R EA. CONDUIT NIPPLE -FOR RIGID GALVANIZED STEEL, 3" DIA, 238-01 BUSHED TYPE, NON -INSULATED INNER WALL, 3" LONG, MALE- THREADED BOTH ENDS ITEM NUMBER - REQUEST NUMBER - * E-0162 A/R EA ELECTRICAL EQUIP. -CONDUIT FITTING 238-01 ITEM NUMBER - 33-999-0009 REQUEST NUMBER - NOTES: 4" PVC FEMALE ADAPTOR * E-0163 A/R EA ELECTRICAL EQUIP. -CONDUIT FITTING 238-01 ITEM NUMBER - 33-999-0D09 REQUEST NUMBER NOTES: 1" PVC FEMALE ADAPTOR * E-0164 A/R EA ELECTRICAL EQUIP. -CONDUIT FITTING 238-01 ITEM NUMBER - 33-999-0009 REQUEST NUMBER NOTES: 1 1/2" PVC FEMALE ADAPTOR E-0165 A/R EA ELECTRICAL EQUIP. -CONDUIT FITTING 238-01 ITEM NUMBER - 33-999-0009 REQUEST NUMBER r, NOTES: c, 2" PVC FEMALE ADAPTOR e< r 4 R ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 11 OF 73 CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0166 A/R EA ELECTRICAL EQUIP. -CONDUIT FITTING 238-01 ITEM NUMBER - 33-999-0009 REQUEST NUMBER - NOTES: 3" PVC FEMALE ADAPTOR * . E-0167 A/R EA ELECTRICAL EQUIP. -CONDUIT FITTING 238-01 ITEM NUMBER - 33-999-0009 REQUEST NUMBER - NOTES: 1" PVC COUPLING SLIP X SLIP * E-0168 A/R EA ELECTRICAL EQUIP. -CONDUIT FITTING 238-01 ITEM NUMBER - 33-999-0009 REQUEST NUMBER - NOTES: 1 1/211 PVC COUPLING SLIP X SLIP * E-0169 A/R EA ELECTRICAL EQUIP. -CONDUIT FITTING 238-01 ITEM NUMBER - 33-999-0009 REQUEST NUMBER - NOTES: 2" PVC COUPLING SLIP X SLIP * E-0170 A/R EA ELECTRICAL EQUIP. -CONDUIT FITTING 238-01 ITEM NUMBER - 33-999-0009 REQUEST NUMBER - NOTES: 3" PVC COUPLING SLIP X SLIP * E-0171 A/R EA ELECTRICAL EQUIP. -CONDUIT FITTING 238-01 ITEM NUMBER - 33-999-0009 REQUEST NUMBER - NOTES: 4" PVC COUPLING SLIP X SLIP * E-0172 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, S�ANDARD 238-01 LOCKNUT, 3/4" DIA, MANUFACTURER STD ITEM NUMBER - 33-020-0411 REQUEST NUMBER * E-0173 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, STANDARD 238-01 LOCKNUT, 1" DIA, MANUFACTURER STD ' ITEM NUMBER - 33-020-0413 REQUEST NUMBER * E-0175 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, S ANDARp 238-01 , LOCKNUT, 1-1/2" DIA, MANUFACTURER STD i ITEM NUMBER - 33-020-0417 REQUEST NUMBER Lei fif � ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT -'STATION #20 PAGE 12 OF 73 . CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0176 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, STANDARD 238-01 LOCKNUT, 2" DIA, MANUFACTURER STD ITEM NUMBER - 33-020-0419 REQUEST NUMBER - * E-0178 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, STANDARD 238-01 LOCKNUT, 3" DIA, MANUFACTURER STD ITEM NUMBER - 33-020-0423 REQUEST NUMBER - * E-0179 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, STANDARD 238-01 LOCKNUT, 4" DIA, MANUFACTURER STD ITEM NUMBER - 33-020-0427 REQUEST NUMBER - * E-0193 A/R EA. CONDUIT FITTING -FOR RIGIDIGALVANIZED STEEL, BUSHING, 238-01 1" DIA, METALLIC, INSULATED ITEM NUMBER - 33-020-0354 REQUEST NUMBER - NOTES: GROUNDING / #4 LUG * E-0195 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, BUSHING, 238-01 1-1/2" DIA, METALLIC, INSULATED ITEM NUMBER - 33-020-0358 REQUEST NUMBER NOTES: GROUNDING / #4 LUG * E-0196 A/R EA, CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, BUSHING, 238-01 2" DIA, METALLIC, INSULATED ITEM NUMBER - 33-020-0360 REQUEST NUMBER NOTES: GROUNDING / #4 LUG * E-0198 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, BUSHING, 238-01 3" DIA, METALLIC, INSULATED 1 ITEM NUMBER - 33-020-0364 REQUEST NUMBER NOTES: GROUNDING / #4 LUG * E-0199 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, BUSHING, 4" DIA, METALLIC, INSULATED 238-01 " ITEM NUMBER - 33-020-0367 REQUEST NUMBER �* NOTES: GROUNDING / #4 LUG ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 13 OF 73 CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0202 A/R EA CONDUIT BODY-HAZ-TYPE LBY, 3/411, FOR RIGID STEEL 238-01 CONDUIT ITEM NUMBER - 33-018-0162 REQUEST NUMBER NOTES: CROUSE-HINDS, LBY-25 * E-0203 A/R EA CONDUIT BODY-HAZ-TYPE LBY, 111, FOR RIGID STEEL CONDUIT 238-01 ITEM NUMBER - 33-018-0163 REQUEST NUMBER NOTES: CROUSE-HINDS, LBY-35 * E-0204 A/R EA CONDUIT BODY-HAZ-TYPE LBY, 1 11211, FOR RIGID STEEL 238-01 CONDUIT ITEM NUMBER - 33-018-0164 REQUEST NUMBER * E-0205 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, BUSHING, 238-01 RE TYPE, 3/411 DIA, 1/2" DIA, MANUFACTURER STD ITEM NUMBER - REQUEST NUMBER NOTES: C-H CAT. # RE21 * E-0207 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, BUSHING, 238-01 RE TYPE, 111 DIA, 3/411 DIA, MANUFACTURER STD ITEM NUMBER - REQUEST NUMBER NOTES: C-H CAT. # RE32 * E-0208 A/R FT. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, BUSHING, 238-01 RE TYPE, 1-1/211 DIA, 3/4" DIA, MANUFACTURER STD ITEM NUMBER - REQUEST NUMBER - * E-0209 A/R FT. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, BUSHING, 238-01 RE TYPE, 211 DIA, 1-1/211 DIA, MANUFACTURER STD ITEM NUMBER - REQUEST NUMBER * E-0210 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, BUSHING, 238-01 RE TYPE, 1-11211 DIA, 111 DIA, MANUFACTURER STD ITEM NUMBER - REQUEST NUMBER NOTES: C-H CAT. # RE53 ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 14 OF 73 , CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0211 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, BUSHING, 238-01 RE TYPE, 211 DIA, 111 DIA, MANUFACTURER STD ITEM NUMBER - REQUEST NUMBER * E-0212 A/R EA CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, RECESSED 238-01 HEAD PLUG, 3/411 DIA, MANUFACTURER STD ITEM NUMBER - 33-020-0455 REQUEST NUMBER - * E-0213 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, RECESSED 238-01 HEAD PLUG, 111 DIA, MANUFACTURER STD ITEM NUMBER - 33-020-0456 REQUEST NUMBER - NOTES: C-H CAT. # PLG3 * E-0215 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, RECESSED 238-01 HEAD PLUG, 1-1/2" DIA, MANUFACTURER STD ITEM NUMBER - 33-020-0458 REQUEST NUMBER NOTES: C-H CAT. # PLG5 * E-0216 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, RECESSED 238-01 HEAD PLUG, 211 DIA, MANUFACTURER STD ITEM NUMBER - 33-020-0459 REQUEST NUMBER NOTES: C-H CAT. # PLG6 * E-0218 A/R EA. CONDUIT FITTING -FOR RIGID GALVANIZED STEEL, RECESSED 238-01 HEAD PLUG, 311 DIA, MANUFACTURER STD ITEM NUMBER - 33-020-0461 REQUEST NUMBER NOTES: C-H CAT. # PLG8 * E-0219 A/R EA CONDUIT BODY-HAZ-TYPE LBH, 1 1/211, FOR RIGID STEEL 238-01 CONDUIT ITEM NUMBER - 33-018-0154 REQUEST NUMBER * E-0220 A/R EA CONDUIT BODY-HAZ-TYPE LBH, 211, FOR RIGID STEEL 238-01 CONDUIT ITEM NUMBER - 33-018-0156 REQUEST NUMBER ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 15 OF 73 . CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0230 A/R EA. CONDUIT BODY -NON HAZ-TYPE LB, 3/4", FORM 8 BODY, 238-01 W/OPEN TYPE GASKET, AND BLANK SHEET STEEL COVER, FOR RIGID STEEL CONDUIT ITEM NUMBER - REQUEST NUMBER NOTES: C-H CAT. # LB28 * E-0231 A/R EA. CONDUIT BODY -NON HAZ-TYPE LB, 111, FORM 8 BODY, 238-01 W/OPEN TYPE GASKET, AND BLANK SHEET STEEL COVER, FOR RIGID STEEL CONDUIT ITEM NUMBER - REQUEST NUMBER NOTES: C-H CAT. # LB38 * E-0234 A/R EA. CONDUIT BODY -NON HAZ-TYPE LB, 2", FORM 8 BODY, 238-01 W/OPEN TYPE GASKET, AND BLANK FERALOY IRON ALLOY COVER, FOR RIGID STEEL CONDUIT ITEM NUMBER - 33-019-0158 REQUEST NUMBER * E-0256 A/R EA_ CONDUIT BODY -NON HAZ-TYPE T, 3/4", FORM 8 BODY, 238-01 W/SOLID TYPE GASKET, AND BLANK SHEET STEEL COVER, FOR RIGID STEEL CONDUIT ITEM NUMBER - 33-019-0358 REQUEST NUMBER * E-0257 A/R EA CONDUIT BODY -NON HAZ-TYPE T, 111, FORM 8 BODY, 238-01 W/SOLID TYPE GASKET, AND BLANK SHEET STEEL COVER, FOR RIGID STEEL CONDUIT ITEM NUMBER - 33-019-0365 REQUEST NUMBER - * E-0276 A/R EA. CONDUIT BODY ACCSY-COVER, BLANK TYPE, SHEET STEEL 238-01 MATERIAL, NEOPRENE, FOR A FORM 8, 3/4" BODY ITEM NUMBER - REQUEST NUMBER - NOTES: C-H CAT. # 28OF * E-0295 A/R EA CONDUIT BODY-HAZ-TYPE GUAL, 1 1/211, W/5" COVER, FOR 238-01 RIGID STEEL CONDUIT ITEM NUMBER - 33-018-0038 REQUEST NUMBER * E-0298 A/R EA. CONDUIT BODY-HAZ-TYPE GUAT, 3/411, W/3" COVER, FOR 238-01�f, RIGID STEEL CONDUITt� ITEM NUMBER - 33-018-0060 REQUEST NUMBER NOTES: C.H. CAT. # GUAT26 ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 16 OF 73 CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0299 A/R EA. CONDUIT BODY-HAZ-TYPE GUAT, 1", W/3" COVER, FOR 238-01 RIGID STEEL CONDUIT ITEM NUMBER - 33-018-0061 REQUEST NUMBER NOTES: C-H CAT. # GUAT36 * E-0304 A/R EA. CONDUIT BODY-HAZ-TYPE GUAX, 3/4", W/3" COVER, FOR 238-01 RIGID STEEL CONDUIT ITEM NUMBER - 33-018-0070 REQUEST NUMBER - NOTES: C-H CAT. # GUAX26 * E-0305 A/R EA. CONDUIT BODY-HAZ-TYPE GUAX, 1", W/3" COVER, FOR 238-01 RIGID STEEL CONDUIT ITEM NUMBER - 33-018-0071 REQUEST NUMBER - NOTES: C-H CAT. # GUAX36 * E-0309 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-CO13 REQUEST NUMBER - NOTES: UTILITY BOX 4" SQUARE x 2 1/2" DEEP ( SPECIAL ) * E-0311 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: THREE GANG DEVICE BOX, C-H, CAT.# FD23 * E-0312 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: DUPLEX RECEPTACLE COVER, C-H, CAT.# DS23 * E-0313 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: THREE GANG SWITCH COVER, C-H, CAT.# S323 * E-0314 A/R EA. CONDUIT BODY-HAZ-TYPE GUA, 111, W/3" COVER, FOR RIGID 238-01 STEEL CONDUIT ITEM NUMBER - 33-018-0003 REQUEST NUMBER NOTES: CONDULET, 1"x 1"x 3/4" C-H CAT.# GUAG7885 ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 17 OF 73 CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0318 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: 4" SQUARE ONE GANG PLASTER RING 1/2" RISE * E-0319 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: 4" SQUARE TWO GANG PLASTER RING 1/2" RISE * E-0320 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: 4" SQUARE 3/0 PLASTER RING 1/2" RISE * E-0321 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: 4" SQUARE ONE GANG SP SWITCH COVER * E-0322 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER NOTES: 4" SQUARE RECEPTACLE DUPLEX COVER * E-0323 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: 4" SQUARE TWO GANGE SP SWITCH COVER * E-0324 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: 4" SQUARE BLANK COVERS i b �,q e,56 * E-0330 A/R EA ELECTRICAL EQUIP. -PULL BOX 238-01 Ofi` ITEM NUMBER - 33-999-0028 REQUEST NUMBER NOTES: PULL BOX GUAG W/ 3" HUB C-H, CAT.# GUAG-8885 6 ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 18 OF 73 CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0331 A/R EA ELECTRICAL EQUIP. -PULL BOX 238-01 ITEM NUMBER - 33-999-0028 REQUEST NUMBER - NOTES: PULL BOX BLANK HUB PLATE C-H, CAT. # RSPO * E-0332 A/R EA ELECTRICAL EQUIP. -PULL BOX 238-01 ITEM NUMBER - 33-999-0028 REQUEST NUMBER - NOTES: PULL BOX w/ COVER & GASKET. C-H CAT.# RS1 * E-0336 A/R EA ELECTRICAL EQUIP. -PULL BOX 238-01 ITEM NUMBER - 33-999-0028 REQUEST NUMBER - NOTES: PULL BOX HUB PLATE. C-H CAT.# RSP2 * E-0339 A/R EA ELECTRICAL EQUIP. -PULL BOX 238-01 ITEM NUMBER - 33-999-0028 REQUEST NUMBER - NOTES: PULL BOX HUB PLATE. C-H CAT.# RSP3 * E-0340 A/R EA ELECTRICAL EQUIP. -PULL BOX 238-01 ITEM NUMBER - 33-999-0028 REQUEST NUMBER - NOTES: PULL BOX HUB PLATE. C-H CAT.#RSP33, * E-0341 A/R EA ELECTRICAL EQUIP. -PULL BOX 238-01 ITEM NUMBER - 33-999-0028 REQUEST NUMBER - NOTES: PULL BOX HUB PLATE. C-H CAT.# RSP333 * E-0345 A/R EA ELECTRICAL EQUIP. -PULL BOX 238-01 ITEM NUMBER - 33-999-0028, REQUEST NUMBER - NOTES: PULL BOX HUB PLATE. C-H CAT.# RSP5 E-0346 A/R EA ELECTRICAL EQUIP. -PULL BOX 238-01 ITEM NUMBER - 33-999-0028 REQUEST NUMBER - NOTES: PULL BOX HUB PLATE. C-H CAT.#RSP55 ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 19 OF 73 . CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0347 A/R EA ELECTRICAL EQUIP. -PULL BOX 238-01 ITEM NUMBER - 33-999-0028 REQUEST NUMBER - NOTES: PULL BOX HUB PLATE PLATE. C-H CAT.# RSP555, 3-'1 1/2" HUBS * E-0348 A/R EA ELECTRICAL EQUIP. -PULL BOX 238-01 ITEM NUMBER - 33-999-0028 REQUEST NUMBER - NOTES: PULL BOX HUB PLATE C-H CAT #RSP66, 2-2" HUBS * E-0359 A/R EA. CONDUIT -FLEXIBLE BRAIDED BRONZE COUPLING, LIQUID 238-01 TIGHT W/UNION, 12" LONG, 1" ITEM NUMBER - 33-016-0068 REQUEST NUMBER - NOTES: FLEX,1", CLASS 1 DIV.1 C.H. # ECLK-312 * E-0360 A/R FT. CONDUIT -FLEXIBLE STEEL OIL RESISTANT, LIQUID TIGHT, 238-01 3/4" ITEM NUMBER - REQUEST NUMBER NOTES: TYPE "UAn * E-0361 A/R FT. CONDUIT -FLEXIBLE STEEL OIL RESISTANT, LIQUID TIGHT, 238-01 1" ITEM NUMBER - 33-016-0051 REQUEST NUMBER NOTES: TYPE "UAu * E-0363 A/R FT. TNT LIQUID CONDUIT FLEXIBLE STEEL 0[L RESISTANT, TIGHT , 238-01 1-1/2" ITEM NUMBER - 33-016-0052 REQUEST NUMBER -I NOTES: "UA" 34 62 TYPE � & * E-0370 A/R EA. CONDUIT FITTING -FOR FLEX METAL, LIQUID TITE, 238-01 & CONNECTOR STRAIGHT TYPE 3 4" DIA MANUFACTURER -" a ED STD, COMPRESSION BY MALE THREADS, INSULATED 1 REC tU ITEM NUMBER 33 020 0074 REQUEST NUMBER r NOTES: Spa 4V T&B CAT. # 5333 OZ6ti� I i 0 ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 20 OF 73 . CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0371 A/R EA. CONDUIT FITTING -FOR ELECTRICAL METALLIC TUBING, 238-01 CONNECTOR, STRAIGHT TYPE, 1" DIA, MANUFACTURER STD, COMPRESSION BY MALE THREADS, INSULATED ITEM NUMBER - REQUEST NUMBER NOTES: T&B CAT. # 5334 * E-0373 A/R EA. CONDUIT FITTING -FOR ELECTRICAL METALLIC TUBING, 238-01 CONNECTOR, STRAIGHT TYPE, 1-1/2" DIA, MANUFACTURER STD, COMPRESSION BY MALE THREADS, INSULATED ITEM NUMBER - REQUEST NUMBER NOTES: T&B CAT. # 5336 * E-0374 A/R EA. CONDUIT FITTING -FOR FLEX METAL, LIQUID TITE, ELBOW, 238-01 90 DEG TYPE, 3/4" DIA, MANUFACTURER STD, FEMALE BY FEMALE THREADS, INSULATED ITEM NUMBER - REQUEST NUMBER - NOTES: T & 6 CAT. # 3742 * E-0375 A/R EA. CONDUIT FITTING -FOR FLEX METAL, LIQUID TITE, ELBOW, 238-01 90 DEG TYPE, 1" DIA, MANUFACTURER STD, FEMALE BY FEMALE THREADS, INSULATED ITEM NUMBER - REQUEST NUMBER NOTES: T & B CAT. # 3743 * E-0378 A/R FT. CONDUIT -FLEXIBLE STEEL NON -LIQUID TIGHT, 1/2" 238-01 ITEM NUMBER - 33-016-0060 REQUEST NUMBER - NOTES: TYPE "UL" * E-0381 A/R EA. CONDUIT FITTING -FOR FLEX METAL, LIQUID TITE, 238-01 CONNECTOR, STRAIGHT TYPE, 1/2" DIA, MANUFACTURER STD, COMPRESSION BY MALE THREADS ITEM NUMBER - REQUEST NUMBER 56 ` NOTES:A T&B CAT.# 254 * E-0390 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ;a ITEM NUMBER - 33-999-0013 REQUEST NUMBER n NOTES: 1.v DRAIN & BREATHER COMBINATION. C-H CAT.# ECD1877 c*3 cbr - Zp2 ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT — STATION #20 PAGE 21 OF 73 . CTR MARK REQUEST QUANTITY UNIT NO, PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0401 A/R FT. POWER CABLE-1 CONDUCTOR, #14 AWG, 7-STRAND COPPER, 238-01 UNSHIELDED, THWN INSULATION ITEM NUMBER - REQUEST NUMBER NOTES: (BLACK) * E-0402 A/R FT. POWER CABLE-1 CONDUCTOR, #14 AWG, 7-STRAND COPPER 238-01 UNSHIELDED, THW INSULATION, 600 VOLT, 75 DEG C ITEM NUMBER - REQUEST NUMBER NOTES: GREEN COLOR FOR GROUND * E-0404 A/R FT. POWER CABLE-1 CONDUCTOR, #12 AWG, 7-STRAND COPPER, 238-01 UNSHIELDED, THWN INSULATION ITEM NUMBER REQUEST NUMBER NOTES: (BLACK) * E-0405 A/R FT. POWER CABLE-1 CONDUCTOR, #12 AWG, 7-STRAND COPPER, 238-01 UNSHIELDED, THW INSULATION, 600 VOLT, 75 DEG C ITEM NUMBER - 35-060-0297 REQUEST NUMBER NOTES: GREEN COLOR FOR GROUND * E-0409 A/R FT. POWER CABLE-1 CONDUCTOR, #10 AWG, 7-STRAND COPPER, 238-01 UNSHIELDED, THW INSULATION, 600 VOLT, 75 DEG C ITEM NUMBER - REQUEST NUMBER - NOTES: GREEN COLOR FOR GROUND * E-0410 A/R FT. POWER CABLE-1 CONDUCTOR, #10 AWG, 7-STRAND COPPER, 238-01 UNSHIELDED, THWN INSULATION ITEM NUMBER - REQUEST NUMBER NOTES: (BLACK) * E-0411 A/R FT. POWER CABLE-1 CONDUCTOR, #8 AWG, 7-STRAND COPPER, 238-01 YZ3 9! UNSHIELDED, THWN INSULATION ,tea ITEM NUMBER REQUEST NUMBER p 159 NOTES: �ft� (BLACK) N , 11. cn ED _74m O ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 22 OF 73 CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER- QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0412 A/R FT. POWER CABLE-1 CONDUCTOR, #8 AWG, 7-STRAND COPPER, 238-01 UNSHIELDED, THW INSULATION ITEM NUMBER - REQUEST NUMBER NOTES: GREEN COLOR FOR GROUND * E-0413 A/R FT. POWER CABLE-1 CONDUCTOR, #6 AWG, 7-STRAND COPPER, 238-01 UNSHIELDED, THW INSULATION ITEM NUMBER - REQUEST ,NUMBER NOTES: (BLACK) * E-0414 A/R FT. POWER CABLE-1 CONDUCTOR, #4 AWG, 7-STRAND COPPER, 238-01 UNSHIELDED, XHHW INSULATION ITEM NUMBER - REQUEST NUMBER NOTES: (BLACK) * E-0415 A/R FT. POWER CABLE-1 CONDUCTOR, #4 AWG, 7-STRAND COPPER', 238-01 UNSHIELDED, THW INSULATION, 600 VOLT, 75 DEG C ITEM NUMBER - REQUEST NUMBER NOTES: GREEN COLOR FOR GROUND * E-0417 A/R FT. - POWER CABLE-1 CONDUCTOR, #2 AWG, 7-STRAND COPPER, 238-01 UNSHIELDED, THW INSULATION ITEM NUMBER - REQUEST NUMBER - NOTES: (GREEN) * E-0418 A/R FT. POWER CABLE-1 CONDUCTOR, #2 AWG, STANDARD STRANDED 238-01 COPPER, UNSHIELDED, XHHW INSULATION, 600 VOLT, 90 DEG C ITEM NUMBER - 35-060-0302 REQUEST NUMBER NOTES: INSULATION TO BE RATED 90 C * E-0419 A/R FT. POWER CABLE-1 CONDUCTOR, #1/0 AWG, 7-STRAND COPPER, 238-01 TJJ UNSHIELDED, THW INSULATION N ITEM NUMBER REQUEST NUMBER w NOTES: (BLACK)b v 4 �� £r ZZ 4 ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 23 OF 73 . CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME-SU; OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0422 A/R FT. POWER CABLE-1 CONDUCTOR, #2/0 AWG, 7-STRAND COPPER, 238-01 UNSHIELDED, THW INSULATION ITEM NUMBER - REQUEST NUMBER NOTES: (GREEN) * E-0423 A/R FT. POWER CABLE-1 CONDUCTOR, #4/0 AWG, CLASS-C 238-01 CONCENTRIC STRANDED COPPER, UNSHIELDED, USE INSULATION, 600 VOLT, 90 DEG C ITEM NUMBER - REQUEST NUMBER NOTES: INSULATION TO BE USE-2 RATED 90 C * E-0424 A/R FT. POWER CABLE-1 CONDUCTOR, 250'MCM, 7-STRAND COPPER, 238.01 UNSHIELDED, XHHW INSULATION ITEM NUMBER - REQUEST NUMBER NOTES: (BLACK) * E-0425 A/R FT. POWER CABLE-1 CONDUCTOR, 350 MCM, 7-STRAND COPPER, 238-01 UNSHIELDED, XHHW INSULATION ITEM NUMBER - REQUEST NUMBER - NOTES: (BLACK) XHHW-2 INSULATION RATED 90 C * E-0426 A/R FT. POWER CABLE-1 CONDUCTOR, 500 MCM, 7-STRAND COPPER, 238-01 UNSHIELDED, USE INSULATION ITEM NUMBER - REQUEST NUMBER - NOTES: (BLACK) USE-2 INSULATION RATED 90 C * E-0448 A/R FT.- CONTROL CABLE-1 PAIR, #16 AWG, STANDARD STRANDED 238-01 COPPER, OVERALL SHIELDED W/STANDARD DRAIN WIRE, POWER LIMITED TRAY CABLE INSULATION, PVC JACKET, 300 VOLT, 90 DEG C ITEM NUMBER - REQUEST NUMBER * E-0449 A/R FT. CONTROL CABLE-2 PAIR, #16 AWG, STANDARD STRANDED 238-01 COPPER, INDIVIDUALLY SHIELDED,TWISTED W/ STD DRAIN WIRE, POWER LIMITED TRAY CABLE INSULATION, PVC VOLT, 90 DEG C ITEM N REQUEST NUMBER ITEM NUMBER ( to 0 r ZZ4�®G�O� ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 24 OF 73 CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0450 A/R FT. CONTROL CABLE-4 PAIR, #16 AWG, STANDARD STRANDED 238-01 COPPER, INDIVIDUALLY SHIELDED,TWISTED W/ STD DRAIN WIRE, POWER LIMITED TRAY CABLE INSULATION, PVC JACKET, 300 VOLT, 90 DEG C ITEM NUMBER - REQUEST NUMBER - * E-0451 A/R FT. CONTROL CABLE-8 PAIR, #16 AWG, STANDARD STRANDED 238-01 COPPER, INDIVIDUALLY SHIELDED,TWISTED W/ STD DRAIN WIRE, POWER LIMITED TRAY CABLE INSULATION, PVC JACKET, 300 VOLT, 90 DEG C ITEM NUMBER - REQUEST NUMBER * E-0452 A/R FT. CONTROL CABLE-12 PAIR, #16 AWG, STANDARD STRANDED 238-01 COPPER, INDIVIDUALLY SHIELDED,TWISTED W/ STD DRAIN WIRE, POWER LIMITED TRAY CABLE INSULATION, PVC JACKET, 300 VOLT, 90 DEG C ITEM NUMBER REQUEST NUMBER * E-0453 A/R FT. CONTROL CABLE-24 PAIR, #16 AWG, STANDARD STRANDED 238-01 COPPER, INDIVIDUALLY SHIELDED,TWISTED W/ STD DRAIN WIRE, POWER LIMITED TRAY CABLE INSULATION, PVC JACKET, 300 VOLT, 90 DEG C ITEM NUMBER - REQUEST NUMBER - * E-0460 A/R FT. CONTROL CABLE-1 TRIAD, #16 AWG, STANDARD STRANDED 238-01 COPPER, OVERALL SHIELDED W/STANDARD DRAIN WIRE, POWER LIMITED TRAY CABLE INSULATION, PVC JACKET, 300 VOLT, 90 DEG C ITEM NUMBER - REQUEST NUMBER - * E-0461 A/R FT. CONTROL CABLE-4 TRIAD, #16 AWG, STANDARD STRANDED 238-01 COPPER, INDIVIDUALLY SHIELDED,TWISTED W/ STD DRAIN WIRE, POWER LIMITED TRAY CABLE INSULATION, PVC JACKET, 300 VOLT, 90 DEG C ITEM NUMBER - REQUEST NUMBER NOTES: (DEKORON CAT. #1884-61680) * E-0462 A/R FT. CONTROL CABLE-8 TRIAD, #16 AWG, STANDARD STRANDED 238-01 COPPER, INDIVIDUALLY SHIELDED,TWISTED W/ STD DRAIN WIRE, POWER LIMITED TRAY CABLE INSULATION, PVC E� E v JACKET, 300 VOLT, 90 DEG C ITEM NUMBER REQUEST NUMBER c' rd lz ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 25 OF 73 CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0463 A/R FT. CONTROL CABLE-12 TRIAD, #16 AWG, STANDARD STRANDED 238-01 COPPER, INDIVIDUALLY SHIELDED,TWISTED W/ STD DRAIN WIRE, POWER LIMITED TRAY CABLE INSULATION, PVC JACKET, 300 VOLT, 90 DEG C ITEM NUMBER REQUEST NUMBER * E-0464 A/R FT. CONTROL CABLE-24 TRIAD, #16 AWG, STANDARD STRANDED 238-01 COPPER, INDIVIDUALLY SHIELDED,TWISTED W/ STD DRAIN WIRE, POWER LIMITED TRAY CABLE INSULATION, PVC JACKET, 300 VOLT, 90 DEG C ITEM NUMBER - REQUEST NUMBER * E-0470 A/R FT. T/C EXT WIRE -TYPE JX THERMOCOUPLE EXTENSION, 4 PAIR, 238-01 #20 AWG, SOLID CONDUCTORS, INDIVIDUAL/OVERALL ALUMINUM/MYLAR SHIELD WITH, PVC INSULATION, PVC JACKET ITEM NUMBER - 35-085-0027 REQUEST NUMBER * E-0471 A/R FT. T/C EXT WIRE -TYPE JX THERMOCOUPLE EXTENSION, 8 PAIR, 238-01 #20 AWG, SOLID CONDUCTORS, INDIVIDUAL/OVERALL ALUMINUM/MYLAR SHIELD WITH DRAIN WIRE, PVC INSULATION, PVC JACKET ITEM NUMBER - 35-085.0029 REQUEST NUMBER * E-0472 A/R FT. T/C EXT WIRE -TYPE JX THERMOCOUPLE EXTENSION, 12 238-01 PAIR, #20 AWG, SOLID CONDUCTORS, INDIVIDUAL/OVER LL ALUMINUM/MYLAR SHIELD WITH DRAIN WIRE, PVC INSULATION, PVC JACKET ITEM NUMBER - 35-085-0083 REQUEST NUMBER * E-0473 A/R FT. T/C EXT WIRE -TYPE JX THERMOCOUPLE EXTENSION, 24 238-01 PAIR, #20 AWG, SOLID CONDUCTORS, INDIVIDUAL/OVER LL ALUMINUM/MYLAR SHIELD WITH DRAIN WIRE, PVC INSULATION, PVC JACKET y3 ITEM NUMBER - REQUEST NUMBER * E-0474 A/R FT. T/C EXT WIRE -TYPE JX THERMOCOUPLE EXTENSION, 36 238-01 PAIR, #20 AWG, SOLID CONDUCTORS, INDIVIDUALLY of SHIELDED WITH OVERALL SHIELD, PVC INSULATION, PVC JACKET ITEM NUMBER - REQUEST NUMBER �£ZZZ62 'Ff6v4i i, ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32, PROJECT NAME: FGT - STATION #20 PAGE 26 OF 73 CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0481 A/R FT. WIRE/CABLE-CABLE 238-01 ITEM NUMBER - 35-999-0001 REQUEST NUMBER - NOTES: CONTROL CABLE - 3/C # 14 CU, 7 STR, UNSHIELDED THWN INSULATION, PVC JACKET, 60OV, 90 C * E-0482 A/R FT. WIRE/CABLE-CABLE 238-01 ITEM NUMBER - 35-999-0001 REQUEST NUMBER - NOTES: CONTROL CABLE - 5/C # 14 CU 7 STR, UNSHIELDED THWN INSULATION, PVC JACKET, 60OV, 90 C * E-0483 A/R FT. WIRE/CABLE-CABLE 238-01 ITEM NUMBER - 35-999-0001 REQUEST NUMBER - NOTES: CONTROL CABLE 7/C # 14 CU, 7 STR, UNSHIELDED THWN INSULATION, PVC JACKET, 60OV, 90 C * E-0484 A/R FT. WIRE/CABLE+CABLE 238-01 ITEM NUMBER - 35-999-0001 REQUEST NUMBER - NOTES: CONTROL CABLE 9/C # 14 CU, 7 STR, UNSHIELDED THWN INSULATION, PVC JACKET, 60OV, 90 C * E-0485 A/R FT. WIRE/CABLE-CABLE 238-01 ITEM NUMBER - 35-999-0001 REQUEST NUMBER - NOTES: CONTROL CABLE 12/C # V14 CU, 7 STR, UNSHIELDER THWN INSULATION, PVC JACKET, 60OV, 90 C * E-0486 A/R FT. WIRE/CABLE-CABLE 238-01 ITEM NUMBER - 35-999-0001 REQUEST NUMBER NOTES: CONTROL CABLE 20/C # 14 CU, 7 STR, UNSHIELDED THWN E-' INSULATION, PVC JACKET, 60OV, 90 C ` 3 4 * E-0487 A/R FT. WIRE/CABLE-CABLE 238-01 ITEM NUMBER 35 999 0007 REQUEST NUMBER NOTES: j V CONTROL CABLE 25/C # 14 CU, 7 STR, UNSHIELDED THWN �s INSULATION, PVC JACKET, 60OV, 90 C 4, ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 27 OF 73 . CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0488 A/R FT. WIRE/CABLE-CABLE 238-01 ITEM NUMBER - 35-999-0001 REQUEST NUMBER - NOTES: CONTROL CABLE 30/C # 14 CU, 7 STR, UNSHIELDER THWN INSULATION, PVC JACKET, 60OV, 90 C * E-0499 A/R FT. WIRE/CABLE-CABLE 238-01 ITEM NUMBER - 35-999-0001 REQUEST NUMBER - NOTES: COAX COMMUNICATIONS CABLE, RG62-A/U, 80 C, FLOODED DIRECT BURIAL TYPE, BELDEN CAT # 9228 OR APPROVED EQUAL * E-0502 A/R EA CONDUIT SEAL -HUB, 1-1/211 X 1", MALE X FEMALE THREADS 238-01 ITEM NUMBER - 33-022-0090 REQUEST NUMBER - NOTES: CONDUIT SEALING HUB, C-H, CAT.# ES-53 * E-0503 A/R EA CONDUIT SEAL -HUB, 211 X 1-11211, MALE X FEMALE THREADS' 238-01 ITEM NUMBER - 33-022-0098 REQUEST NUMBER NOTES: CONDUIT SEALING HUB, C-H, CAT # ES-65 * E-0600 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER NOTES: GLOBESTRUT CAT. # G-5812 GALVANIZED FRAMING CHANNEL * E-0601 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER NOTES: GLOBESTRUT CAT.# G-1432, 1/4-20SPRING NUT * E-0602 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER NOTES: GLOBESTRUT CAT.# G-1434,3/8-16 SPRING NUT q. * E-0603 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER NOTES: ray VVV �V GLOBESTRUT CAT.# 7003, 3/411 RIGID CONDUIT CLAMPS Sz 1'L ZL 6Z02 ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: 522138MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 28 OF 73 CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0604 AIR EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER NOTES: GLOBESTRUT CAT.#G-7004, 1" RIGID CONDUIT CLAMPS * E-0605 AIR EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: GLOBESTRUT CAT.# G-7006, 1-1/2" RIGID CONDUIT CLAMPS * E-0606 AIR EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: GLOBESTRUT CAT.# G-7007, 2" RIGID CONDUIT CLAMPS * E-0607 AIR EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: GLOSESTRUT CAT. # G-7009, 3" RIGID CONDUIT CLAMPS * E-0608 AIR EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER NOTES: GLOBESTRUT CAT. #G-7103, 3/4" EMT CLAMPS E-0609 AIR EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER NOTES: - GLOBESTRUT CAT. #G-7104, 1" EMT CLAMPS * E-0610 AIR EA ' ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER NOTES: KORNS„CONDUIT SUPPORTS, 3/4" RIGHT ANGLE $A'E' * E-0611 AIR EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 h ITEM NUMBER - 33-999-0013 REQUEST NUMBER NOTES: KORNS„ CONDUIT SUPPORTS, 3/4" PARALLEL as\ \\ sn ti ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: 522138 MATERIALS LIST RUN TIME: 16.41.32 73 PROJECT NAME: FGT - STATION #20 PAGE 29 OF CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0612 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: KORNS, CONDUIT SUPPORTS, 1" RIGHT ANGLE * E-0613 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER NOTES: KORNS,CONDUIT SUPPORTS,1" PARALLEL * E-0614 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER NOTES: KORNS,CONDUIT SUPPORTS, 1-1/2" RIGHT ANGLE * E-0615 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER NOTES: KORNS,CONDUIT SUPPORTS 1-1/2" PARALLEL * E-0616 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: CABLE & CONDUIT HANGER, 3/4", C-H CAT.# MW1-6 * E-0617 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: CABLE & CONDUIT HANGER, 1", C-H CAT. # MW2-B * E-0618 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: CABLE & CONDUIT HANGER, 1-1/2", C-H CAT. # MW4-B * E-0619 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER A5g 7 NOTES: y CABLE & CONDUIT HANGER, 2", C-H CAT. # MW5-B �P h 1 0 ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT — STATION #20 PAGE 30 OF 73 CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0621 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: 3/4" MALLEABLE IRON CONDUIT CLAMPS, C-H CAT. # MW511 * E-0622 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: 1" MALLEABLE IRON CONDUIT CLAMPS. C-H, CAT.# MW512 * E-0623 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER NOTES: 1-1/2" MALLEABLE IRON CONDUIT CLAMPS. C-H, CAT. # MW514 * E-0627 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: 3/81lx3" LONG, LAG BOLTS E-0628 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: 5/8"x 16" LONG, GALV. THRU BOLTS w/ WASHERS E-0629 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER NOTES: 1/4 x 20 NUTS 8 BOLTS, 1-1/2" LONG * E-0630 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 A- 676 ITEM NUMBER 33-999-0013 REQUEST NUMBER)q NOTES: GLOBE STRUT SHORT SINGLE COLUMN BASE. CAT # G-5101 �i W * E-0636 A/R EA ELECTRICAL EQUIP. -LIGHTING FIXTURE 237-01 1i ��; ITEM NUMBER - 33-999-0019 REQUEST NUMBER - C�`s'V NOTES: FLOODLIGHT, 400 WATT, HIGH PRESSURE SODIUM LUMARKy���� pZ CAT.# HPNH-S7-400 OR APPROVED EQUAL ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE. 12/03/93 PROJECT NUMBER: 522138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 31 OF 73 . CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0637 A/R EA ELECTRICAL EQUIP. -LIGHTING FIXTURE 237-01 ITEM NUMBER - 33-999-0019 REQUEST NUMBER NOTES: FLOODLAMP 400 WATT HIGH PRESSURE SODIUM G.E. CAT.# LU-400 OR APPROVED EQUAL * E-0641 A/R EA ELECTRICAL EQUIP. -LIGHTING FIXTURE 237-01 ITEM NUMBER - 33-999-0019 REQUEST NUMBER NOTES: 35' BREAKOVER POLE 2-3/8" T LUMARK CAT.# HTS6B35SP OR APPROVED EQUAL * E-0642 A/R EA ELECTRICAL EQUIP. -LIGHTING FIXTURE 237-01 ITEM NUMBER - 33-999-0019 REQUEST NUMBER NOTES: LOWERING DEVICE W/ 35' CABLE & HOOK LUMARK CAT.# HSSLDW OR APPROVED EQUAL * E-0645 A/R EA ELECTRICAL EQUIP. -LIGHTING FIXTURE 237-01' ITEM NUMBER - 33-999-0019 REQUEST NUMBER NOTES: BULLHORN THREE FIXTURE TYPE 'LUMARK CAT.# 101-Y33 OR APPROVED EQUAL * E-0648 A/R EA ELECTRICAL EQUIP. -LIGHTING FIXTURE 237-01 ITEM NUMBER - 33-999-0019 ''REQUEST NUMBER NOTES: WALLPACK LIGHTING FIXTURE, 100 WATT G.E. CAT.# W17L1OSOH1SN4DB OR APPROVED EQUAL * E-0649 A/R EA ELECTRICAL EQUIP. -LIGHTING FIXTURE 237-01 A5 7,& ITEM NUMBER - 33-999-0019 REQUEST NUMBER - NOTES: A,I,3 / k Pr'a METAL HALIDE, LOW BAY, GE SB1 INDUSTRIAL LUMINAIRE, lj` ^� 100 W 120/240 VAC, 60 HZ, WITH ENCLOSED ACRYLIC ��e{{{ LENSE AND PENDUNT HANGER. APPROVED EQUAL. �� V GE SB1-10-M-O-H-LBR-WH OR v v$ Z 4Z * E-0651 A/R EA ELECTRICAL EQUIP. -LIGHTING FIXTURE 237-01 ITEM NUMBER - 33-999-0019 REQUEST NUMBER NOTES: LIGHTING FIXTURE INCANDESCENT 100 WATT C-H CAT. # VXHA2199 OR APPROVED EQUAL ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 32 OF 73 MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY 9CTR FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0652 A/R EA ELECTRICAL EQUIP. -LIGHTING FIXTURE 237-01 ITEM NUMBER - 33-999-0019 REQUEST NUMBER - NOTES: LIGHTING FIXTURE BRACKET 100 WATT H.P.S. C-H CAT.# VMVS2TW100GP/120 OR APPROVED EQUAL * E-0653 A/R EA ELECTRICAL EQUIP. -LIGHTING FIXTURE 237-01 ITEM NUMBER - 33-999-0019 REQUEST NUMBER NOTES: LIGHTING FIXTURE HIGH BAY 250 WATT M.H. * E-0654 A/R EA ELECTRICAL EQUIP. -LIGHTING FIXTURE 237-01 ITEM NUMBER - 33-999-0019 REQUEST NUMBER - NOTES: WALL BRACKET TYPE, 150 WATT INCANDESCENT, C-H CAT. # EVBX204 WITH RECTANGULAR EXIT SIGN MOUNTED BELOW. * E-0655 A/R EA ELECTRICAL EQUIP. -LIGHTING FIXTURE 237-01 ITEM NUMBER - 33-999-0019 REQUEST NUMBER NOTES: LIGHTING FIXTURE PENDANT MOUNT 100 WATT INCANDESCANTC-H CAT. # EVA2401 * E-0656 A/R EA ELECTRICAL EQUIP. -LIGHTING FIXTURE 237-01 ITEM NUMBER - 33-999-0019 REQUEST NUMBER - NOTES: LIGHTING FIXTURE TWO LAMP SLIMLINE INDUSTRIAL W/REFLECTOR * E-0660 A/R EA ELECTRICAL EQUIP. -LIGHTING FIXTURE 237-01 " 78s� ITEM NUMBER - 33-999-0019 REQUEST NUMBER NOTES: LAMP, 150 WATT INCANDESCANT p w `E * E-0661 A/R EA ELECTRICAL EQUIP. -LIGHTING FIXTURE 237-01 N ITEM NUMBER - 33-999-0019 REQUEST NUMBER NOTES: S2�z �1ZOZ6y LAMP 100 WATT H.P.S. G.E. CAT #LU-100 * E-0662 A/R EA ELECTRICAL EQUIP. -LIGHTING FIXTURE 237-01 ITEM NUMBER - 33-999-0019 REQUEST NUMBER NOTES: LAMP, 250 WATT METAL HALIDE, G.E.CAT# MXR250/BU ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: 522138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 33 OF 73 CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0663 A/R EA ELECTRICAL EQUIP. -LIGHTING FIXTURE 237-01 ITEM NUMBER - 33-999-0019 REQUEST NUMBER NOTES: EMERGENCY LIGHT BATTERY POWERED. TELEDYNE CAT.# 25C668 * E-0670 A/R EA ELECTRICAL EQUIP. -LIGHTING FIXTURE 237-01 ITEM NUMBER - 33-999-0019 REQUEST NUMBER NOTES FLEXIABLE CUSHION HANGER CLASS 1 DIV. 2 C-H CAT.# EFHX-221 * E-0673 A/R EA ELECTRICAL EQUIP. -LIGHTING FIXTURE 237-01 ITEM NUMBER - 33-999-0019 REQUEST NUMBER - NOTES: ADJUSTABLE FIXTURE HANGER,C-H CAT.# UNR29 * E-0675 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: MOLD "GT" CADWELD TYPE GTC-331V * E-0676 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999--0013 REQUEST NUMBER NOTES: MOLD "GR" CADWELD TYPE GRC-331V * E-0677 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER NOTES: MOLD "GT" CADWELD TYPE GTC- 332G * E-0678 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01fig6PlO ITEM NUMBER - 33-999-0013 REQUEST NUMBER NOTES: MOLD "GR" CADWELD TYPE GRC-332G c, * E-0679 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER NOTES:S'`' MOLD"TA" #2/0 TAP, #2/0 RUN, CADWELD TYPE TAC-2G2G ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: 522138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 34 OF 73 CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0680 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: MOLD "TA" #2 TAP, #2/0 RUN, CADWELD TYPE TAC-2GIV * E-0681 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER NOTES: MOLD "SS" #2/0 SPLICE CADWELD TYPE SSC-2G * E-0682 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: MOLD "PT" #2/0 TAP ,#2/0 RUN CADWELD TYPE PTC-2G2G * E-0684 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER NOTES: HANDLE w/FLINT GUN CADWELD TYPE L-160 * E-0686 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER NOTES: WELD METAL #65 CADWELD * E-0687 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER NOTES: WELD METAL #90 CADWELD * E-0688 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER NOTES: WELD METAL #115 CADWELD 55678 Av tg �p * E-0692 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER rn NOTES: r SERVIT POST ,GROUNDING CONNECTOR #2 BURNDY RECE�V CAT.#K2C25 spa 11.. NGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 ROJECT NUMBER: S22 r 38 MATERIALS LIST RUN TIME: 16:41:32 ROJECT NAME: FGT - STATION #20 PAGE 35 OF 73 CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT r ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0693 A R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER NOTES: SERVIT POST, GROUNDING CONNECTOR #2/0 BURNDY CAT. #K2C28 * E-0694 A EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: BURNDY GROUND ROD CLAMP CAT.#GAR6429 * E-0695 A R EA ELECTRICAL EQUIP. -GROUND ROD 238-01 ITEM NUMBER - 33-999-0016 REQUEST NUMBER - NOTES: GROUND ROD 3/4" DIA. x 10'-0" LG.'GALVANIZED STEEL * E-0700 A R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: TEST WELL 12" DIA. CONCRETE PIPE 18" LONG WITH BELLED END & COVER * E-0702 AIR EA ELECTRICAL EQUIP. -ELECTRICAL PART - 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER NOTES: 2/0 ONE BOLT SINGLE BARREL MECHANICAL LUG T&B CAT.# 31011 * E-0705 A/R EA ELECTRICAL EQUIP. -LIGHT SWITCH 237-01 ITEM NUMBER- 33-999-0018 REQUEST NUMBER 8g'® NOTES: y3 77> WATER PROOF SWITCH w/ COVER C.H. CAT.# EDSC2192 M l iTl * E-0706 A/R EA ELECTRICAL EQUIP. -RECEPTACLE 237-01 ITEM NUMBER - 33-999-0030 REQUEST NUMBER \` NOTES: Pc* DEDICATED 120V DUPLEX RECEPTACLE ORANGE, BRYANT CAT. # 8200-1G$Z * E-0707 A/R EA ELECTRICAL EQUIP. -RECEPTACLE 237-01 ITEM NUMBER - 33 999-0030 REQUEST NUMBER NOTES: 120V GFIC DUPLEX RECEPTACLE, BRYANT CAT. # GFR52FT-1 I R T 1 1 FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 ENGINEERING DESIGN PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 36 OF 73 CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED- TRANSFERRED SURPLUS INSTALLED * E-0710 A/R EP ELECTRICAL EQUIP. -LIGHT SWITCH 237-01 ITEM NUMBER - 33-999-0018 REQUEST NUMBER NOTES: SINGLE POLE SWITCH, LEVITON CAT. # 1101-1 * E-0711 A/R EA ELECTRICAL EQUIP. -RECEPTACLE 237-01 ITEM NUMBER - 33-999-0030 REQUEST NUMBER NOTES: DUPLEX RECEPTACLE, LEVITON, CAT. # 5262-1 * E-0713 A/R EA ELECTRICAL EQUIP. -LIGHT SWITCH 237-01 ITEM NUMBER - 33-999-0018 REQUEST NUMBER - NOTES: SINGLE POLE SWITCH PLATE, HUBBELL CAT. # 92071 * E-0714 A/R EA ELECTRICAL EQUIP. -LIGHT SWITCH 237-01 ITEM NUMBER - 33-999-0018 REQUEST NUMBER NOTES: 2 GANG SWITCH PLATE, HUBBELL, CAT. # 92072 * E-0716 A/R EA ELECTRICAL EQUIP. -RECEPTACLE 237-01 ITEM NUMBER - 33-999-0030 . REQUEST NUMBER - NOTES: DUPLEX RECEPTACLE PLATE, HUBBELL, CAT.;# 92101 * E-0718 A/R EA ELECTRICAL EQUIP. -LIGHT SWITCH 237-01 ITEM NUMBER - 33-999-0018 REQUEST NUMBER - NOTES• 1 2 GANG SWITCH PLATE, CAST METAL, C-H CAT. # S3226 * E-0722 A/R E ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER NOTES: TERMINAL MOUNTING RAIL T&B CAT. # HR3490 , f;6A C * E-0723 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER @ �w'` IN NOTES: �•, a TERMINAL, T&B CAT. # NR3450 M`M F ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST _RUN TIME: 16:41:32 PROJECT NAME: fGT STATION #20 PAGE 37 OF 73 CTR MARK REQUEST QUANTITY i UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY- QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTIONIi PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0124 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST'NUMBER NOTES: TERMINAL END BARRIER, T&B CAT. # HIR3460 * E-0725 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: TERMINAL PARTITION, T&B CAT, # HR3461 * E-0726 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: TERMINAL STOP, T&B CAT. # HR3414 * E-0727 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: 21lx4" PANDUIT, CAT. # E2X4LG6A * E-0 28 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: COVER, PANDUIT, CAT. # C2LG6 * E-0 29 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: MODULAR CONTROL DEVICE BODY, SINGLE DEVICE, C-H CAT. #EDSC271 CAST BODY, 3/4" HUB, FEED THRU * E-0730 A/R EA ELECTRICALEQUIP.-ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: MODULAR CONTROL DEVICE BODY, 2-GANG TANDEM, C-H CAT. j #EDSCM32 CAST BODY, 3/4" HUB, FEED THRU * E-0731 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01�i ITEM NUMBER - 33-999-0013 REQUEST NUMBER NOTES: MODULAR CONTROL DEVICE BODY, 3-GANG TANDEM, C-H CAT.+ #EDSCM33 CAST BODY, 1" HUB, FEED THRU rk T'?C2 ZZ G�0 ■ ENGINEERING DESIGN- FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: 522138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 38 OF 73 . CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0732 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: COVER AND DEVICE SUB -ASSEMBLY, WITH 1 PILOT LIGHT, FACTORY SEALED, C-H CAT # DSD946-J11, BLUE COLOR LENSE * E-0733 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: COVER AND DEVICE SUB -ASSEMBLY, WITH 2 PILOT LIGHTS, FACTORY SEALED, C-H CAT # DSD947-JXX-JXX, COLOR OF LENSE AS SHOWN ON DRAWINGS * E-0734 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: COVER AND DEVICE SUB -ASSEMBLY, WITH SELECTOR SWITCH, THREE POSITION, W/LABEL "HAND OFF AUTO",TWO CIRCUIT, FACTORY SEALED, C-H CAT # DSD925 * E-0735 A/R EA ELECTRICAL EOUIP.-LIGHTING PANEL 237-01 ITEM NUMBER - 33-999-0020 REQUEST NUMBER - NOTES: LIGHTING PANELBOARD - (1) ENCLOSURE NEMA 1 100 AMP MAIN 24/CKT W/20 20AMP BREAKERS, WITH ENGRAVED NAMEPLATE "UPS-1" * E-0736 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: COVER AND DEVICE SUB -ASSEMBLY, WITH SELECTOR SWITCH, 3-POSITION, TWO CIRCUIT, W/LABEL "OFF AUTO", FACTORY SEALED, C-H CAT # DSD923 * E-0737 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: HRC THERMOSTAT W/ HONEYWELL CONTROLS, CLASS 1, DIV 1, EXPLOSION PROOF, C-H CAT # HRC85, W/ 3/4" HUB�� 1g'F FEED THRU, 45-85 F, 1 DEG DEADBAND NON AJUSTABLE. i ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 39 OF 73 . MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0746 A/R EA ELECTRICAL EQUIP. -LIGHTING FIXTURE 237-01 ITEM NUMBER - 33-999-0019 REQUEST NUMBER - NOTES: EXIT LIGHT, PRESCOLITE CAT.# 75321 : UNIVERSAL MTG. W/TWIN FACEPLATES & UNIVERSAL ARROWS. * E-0747 A/R EA ELECTRICAL EQUIP. -LIGHTING FIXTURE 237-01 ITEM NUMBER - 33-999-0019 REQUEST NUMBER NOTES: EXIT LIGHT, PRESCOLITE CAT.# 75121 : UNIVERSAL MTG. W/SINGLE FACEPLATES & UNIVERSAL ARROWS. * E-0767 A/R EA ELECTRICAL EQUIP. -LIGHTING PANEL 237-04 ITEM NUMBER - 33-999-0020 REQUEST NUMBER - NOTES: PANELBOARD; SURFACE TRIM, NEMA 1, 120/240 VOLT, 1-PHASE, 150A MCB WITH ISOLATED NEUTRAL AND GROUND BAR KITS. 8-20/1 BRANCH BREAKERS WITH 16 SINGLE POLE SPACES. FOR UTILITY BUILDING AUXILLARY SERVICES_ * E-0769 A/R EA ELECTRICAL EQUIP. -TRANSFORMER - 237-01 ITEM NUMBER - 33-999-0033 -REQUEST NUMBER NOTES: DRY -TYPE, FLOOR MOUNT, INDOOR/OUTDOOR RATED, 480 VAC . 120/240 SINGLE PHASE, 25 KVA, 80 DEGREE C RISE ABOVE 40 DEGREE C AMBIENT, MANUFACTURER INSTALLED GROUND LUGS, UNIVERSAL TAP ARRANGEMENT WITH TWO 2-1/2 PERCENT TAPS ABOVE AND BELOW NORMAL, NEMA STANDARD NOISE RATING. FOR AUXILLARY ROOM UTILITY SERVICES. * E-0772 A/R EA ELECTRICAL EQUIP. -RECEPTACLE 237-01 � ITEM NUMBER - 33-999-0030 REQUEST NUMBER t;+ NOTES: RECEPTACLE, 20A 120/240 VAC, 60 HZ, RATED FOR CLASS 1, DIV. 2, GROUP D. MANUFACTOR AND STYLE TO MATCH15': EXISTING APPLETON, C-H OR OTHER MANUFACTOR AND STYLE AS INPLACE WITHIN EXISING COMPRESSOR BUILDINGS. ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 40 OF 73 CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-0774 A/R EA ELECTRICAL EQUIP. -DISTRIBUTION PANEL 235-01 ITEM NUMBER - 33-999-0010 REQUEST NUMBER - NOTES: 200A FUSE DISCONNECT, 480V, 3-PHASE, 4-WIRE, COMPLETE WITH NEMA-4 ENCLOSURE *` E-0775 A/R EA ELECTRICAL EQUIP. -RECEPTACLE 238-01 ITEM NUMBER - 33-999-0030 REQUEST NUMBER NOTES: 200 AMP, 4 WIRE, THREE PHASE, RUSSELLSTHOL FCRi7144 OR APPROVED EQUAL * E-0781 A/R FT. JUNCTION BOX-HAZARDOUS/RAINTIGHT/WATERTIGHT, FLANGED 238-01 COVER FOR SURFACE MOUNTING, WITH 4 MOUNTING FEET AND AN INTERNAL MOUNTING PAD, BOSSED HOLE/5 THREAD TAP CONDUIT OPENING, 8" LONG, BY 14" WIDE, BY 8" DEEP ITEM NUMBER - REQUEST NUMBER - NOTES: C-H CAT # EJ6813803 OCO-COC-GGG-COC TAG # JB-1 * E-0782 A/R FT. ENCLOSURE-NEMA TYPE 4X, 24" HIGH, X 24" WIDE, X 8" 238-01 DEEP, WITH FULL BACK -PANEL, WITH DOCUMENT POCKLT ITEM NUMBER - REQUEST NUMBER NOTES: HOFFMAN A-24H24B-LP OR EQUAL WITH THREE (3) ROWS OF 48 TERMINALS BY WEIDMULLER SAK 2.5 OR EQUAL TAG: MARSHELING POINTS FOR JUNCTION POINTS PER SITE PLANS. * E-0787 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER NOTES: TWO GANG DEVICE BOX C-H CAT.#EDSC272 3 5 �4, ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 41 OF 73 CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED E-0790 1 EA ELECTRICAL EQUIP. -DISTRIBUTION PANEL 237-01 ITEM NUMBER - 33-999-0010 REQUEST NUMBER - 71 NOTES: STATION DISCONNECT. GENERAL ELECTRIC SPECTRA BREAKER, 480 VAC, 3 PHASE, 50KIC, 100% RATED SKHA36AT0800 FRAME, 800 AMP SENSOR, 600 AMP TRIP NEMA 3R ENCLOSURE. FOR MOUNTING ON 2" POST. ENCLOSURE TO INCLUDE A 50% RATED GROUNDABLE NEUTRAL. BREAKER ORDERED AS PACKAGE WITH MCC SECTIONS PURCHASED FROM GE SUPPLY MARK NO. E-2510. DO NOT DUPLICATE. * E-0791 1 EA JUNCTION BOX-RAINTIGHT/WAITERTIGHT, HINGED COVER FOR 238-01 SURFACE MOUNTING, 48" LON,G, BY 811 WIDE, BY 8" DEEP ITEM NUMBER - 33-045-0002REQUEST NUMBER - NOTES: HOFFMAN NEMA-3R WIRING TROUGH. CAT# A-8848RT * E-1002 A/R FT INSTRUMENT TUBING-STAINLE!SS STEEL, 1/4" D.D. X, 344-SS 0.035" WALL, SEAMLESS, SOFT ANNEALED, ASTM A632, GRADE TP-316 ITEM NUMBER - 10-050-0004REQUEST NUMBER NOTES:• ; 1/4" OD x.035 WALL 316 SS SEAMLESS, ANNEALED TUBING * E-1004 A/R FT INSTRUMENT TUBING -STAINLESS STEEL, 3/8" O.D. X, 344-SS 0.035" WALL, SEAMLESS, SOFT ANNEALED, ASTM A632, GRADE TP-316 ITEM NUMBER - 10-050-0006 REQUEST NUMBER - NOTES: 3/8"OD X .049 WALL 316 SS SEAMLESS, ANNEALED TUBING * E-1006' A/R FT INSTRUMENT TUBING -STAINLESS STEEL, 1/2" O.D. X, 344-SS 0.049" WALL, SEAMLESS, SOFT ANNEALED, ASTM A269, GRADE TP 316 p5671,9 ITEM NUMBER - 10-050-0008 REQUEST NUMBER NOTES: P a 1/2" OD X .062 WALL 316 SS SEAMLESS,ANNEALED TUBING` W� CCCg 19t * E-1010 A/R EA CONTROL EQUIPMENT -INSTRUMENT FITTING 525-01 QVIA ITEM NUMBER - 30-998-0004 REQUEST NUMBER N/2ESITYDRAULIC 111 HOSE, SINGLE WIRE BRAID AEROQUIP9EZZZVO # FC300-10 - - ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 42 OF 73 CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEMDESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-1011 A/R EA CONTROL EQUIPMENT -INSTRUMENT FITTING 525-01 ITEM NUMBER - 30-998-0004 REQUEST NUMBER - NOTES: 1/2" PIPE TO 37 DEG FLARE ADAPTER AEROQUIP # 2021-8-10S * E-1012 A/R EA CONTROL EQUIPMENT -INSTRUMENT FITTING 525-01 ITEM NUMBER - 30-998-0004 REQUEST NUMBER - NOTES: 1/2" REUSABLE FITTING MALE AEROQUIP # 4412-8-10S * E-1013 A/R EA CONTROL EQUIPMENT -INSTRUMENT FITTING 525-01 ITEM NUMBER - 30-998-0004 REQUEST NUMBER - NOTES: 1/211 REUSABLE SWIVEL FITTING FEMALE AEROQUIP # 4411-105 * E-1059 A/R FT PIPE -AS DESCRIBED BELOW: 344-00 ITEM NUMBER - 10-999-0001 REQUEST NUMBER - NOTES: MULTITUBE BUNDLE, (7) 1/4" OD x.040 NIGH-OENSITYPOLYETHYLENE TUBES.FLAME RETARDANT PVC JACKET, DEKORON 1220-407 * E-1078 A/R EA ELECTRICAL EQUIP'. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: FIRE PROTECTION SLEEVE FOR PLASTIC TUBE, CSD SEALING SYSTEM 20/10 AFS, IN 40" LENGTHS E-1190 5 EA CONTROL EQUIPMENT -REGULATOR -INSTRUMENT 526-01 ITEM NUMBER - 30-998-0006 REQUEST NUMBER - 66 NOTES: PRESSURE REDUCING REGULATOR, FISHER 67AFR E-1201 15 EA VALVE -INSTRUMENT VALVE MANIFOLD 526-01 ;`y" °o ITEM NUMBER - 17-998-0002 REQUEST NUMBER - 67 NOTES: ^n 0 W BLOCK AND BLEED 2-VALVE MANIFOLD, TEFLON PACKING, INTEGRAL SEAT, A479-316 STAINLESS STEEL BODY, 0 rn STANDARD ORIFICE, 4-1/2" FNPT CONNECTIONS, MAX N \, PRESSURE 6000 PSI/-20 TO 100 DEG F AGCO PTMVDS-4 OR APPROVED EQUAL £ZZZIZU DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 ENGINEERING PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 43 OF 73 CTR M RK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NU BER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED E 202 3 EA VALVE -INSTRUMENT VALVE MANIFOLD 526-01 ITEM NUMBER - 17-998-0002 REQUEST NUMBER - 67 NOTES: 3-VALVE MANIFOLD, REINFORCED TEFLON PACKING, INTEGRAL SEATS, 316 STAINLESS STEEL BODY, STANDARD ORIFICE, 4-1/2" FNPT CONNECTIONS, MAX PRESSURE 6000 PSI/-20 TO 100 DEG F AGCO M1VDS-4 OR APPROVED EQUAL E-'1297 10 EA CONTROL EQUIPMENT -INSTRUMENT FITTING 526-01 ITEM NUMBER - 30-998-0004 REQUEST NUMBER - 68 NOTES: EXHAUST NOISE MUFFLER 1/2" MNPT SHAFER MODEL # P05-1500 ONLY. * E-1310 A/R EA 999 FITTING -AS DESCRIBED BELOW: 330-01 ITEM NUMBER - 12-999-0001 REQUEST NUMBER - NOTES: 1/4" DDT x 1/8" MNPT STRAIGHT TUBING CONNECTOR, SWAGELOK SS-400-1-2 * E-1312 A/R EA 999 FITTING -AS DESCRIBED BELOW: 330-01 ITEM NUMBER - 12-999-0001 REQUEST NUMBER - NOTES: - 1/4" ODT x 1/4" MNPT STRAIGHT TUBING CONNECTOR, SWAGELOK SS-400-1-4 * E 1314 A/R EA 999 FITTING -AS DESCRIBED BELOW: 330-01 ITEM NUMBER - 12-999-0001 REQUEST NUMBER - NOTES: 1/4" ODT x 3/8" MNPT STRAIGHT TUBING CONNECTOR, SWAGELOK SS-400-1-6 * E-1315 A/R EA 999 FITTING -AS DESCRIBED BELOW: 330-01 ITEM NUMBER - 12-999-0001 REQUEST NUMBER m NOTES: 1/4" DDT x 1/21, MNPT STRAIGHT TUBING CONNECTOR, y+ SWAGELOKJ SS 400-1 8 * E-1316 A/R EA 999 FITTING -AS DESCRIBED BELOW: 330-01 ITEM NUMBER - 12-999-0001 REQUEST NUMBER - NOTES: 3/811 DOT x 1/4" MNPT STRAIGHT TUBING CONNECTOR, SWAGELOK SS-600-1-4 ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION # 0 PAGE 44 OF 73 CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-1317 A/R EA 999 FITTING -AS DESCRIBED BELOW: 330-01 ITEM NUMBER - 12-999-0001 REQUEST NUMBER NOTES: 3/811 ODT X 3/811 MNPT STRAIGHT TUBING CONNECTOR SWAGELOK SS-600-1-6 * E-1318 A/R EA 999FITTING-AS DESCRIBED BELOW: 330-01 ITEM NUMBER -"12-999-0001 REQUEST NUMBER - NOTES: 3/81, DDT x 1/211 MNPT STRAIGHT TUBING CONNECTOR, SWAGELOK SS-600-1-8 * E-1319 A/R EA 999 FITTING -AS DESCRIBED BELOW: 330-01 ITEM NUMBER - 12-999-0001 REQUEST NUMBER - NOTES: 1/211 DDT X 1/211 MNPT STRAIGHT TUBING CONNECTOR, SWAGELOK SS-810-1-8 * E-1320 A/R EA 999 FITTING -AS DESCRIBED BELOW: 330-01 ITEM NUMBER- 12-999-0001 REQUEST NUMBER NOTES: 11211 DDT X 1/411 MNPT STR. TUBING CONN.SWAGELOK SS-810-1_y * E-1321 A/R EA 999 FITTING -AS DESCRIBED BELOW: 330-01 ITEM NUMBER - 12-999-0001 REQUEST NUMBER - NOTES: BAR STOCK NIPPLE, 1/211 BY 211 MNPT, STAINLESS STEEL, 5000 PSIG MIN WORKING PRESSURE. CAJON SS-8-HLN-2.00 * E-1326 A/R EA 999 FITTING -AS DESCRIBED BELOW: 330-01 ITEM NUMBER - 12-999-0001` REQUEST NUMBER NOTES: 3/811 ODT X 3/811 ODT DIELECTRIC TUBING CONNECTOR, CAJON SS-4-DE-6 3� * E-1327 A/R EA 999 FITTING -AS DESCRIBED BELOW: 330-01c r ITEM NUMBER - 12-999-0001 REQUEST NUMBER NOTES: 1/211 DDT x 1/211 DDT DIELECTRIC TUBING CONNECTOR,\` v CAJON SS-8-DE-6 v 46 ...ail... s i I i ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 RUN TIME: 16:41:32 PROJECT NUMBER: S22138 MATERIALS LIST PAGE 45 OF 73 PROJECT NAME: FGT - STATION #20 UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY CTR MARK REQUEST QUANTITY ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED FUR NUMBER AND UNIT * E-1331 A/R EA 999 FITTING -AS DESCRIBED BELOW,: 330-01 ITEM NUMBER - 12-999-0001 REQUEST NUMBER NOTES: 1/4" DDT TUBING UNION, SWAGELOK SS-400-6 * E-1333 A/R EA 999 FITTING -AS DESCRIBED BELOW: 330-01 ITEM NUMBER - 12-999-0001 REQUEST NUMBER NOTES: 1/2" DDT TUBING UNION, SWAGELOK SS-810-6 * E 3336 A/R EA 999 FITTING -AS DESCRIBED BELOW: 330-01 ITEM NUMBER - 12-999-0001 REQUEST NUMBER NOTES: 1/4" DDT TUBING INSERT, SWAGELOK SS-405-170 * E-1337 A/R EA 999 FITTING -AS DESCRIBED BELOW: 330-01 ITEM NUMBER - 12-999-0001 REQUEST NUMBER NOTES: 3/8" DDT TUBING INSERT, SWAGELOK SS-605-4 * E-1341 A/R EA 999 FITTING -AS DESCRIBED BELOW: 330-01 ITEM NUMBER - 12-999-0001 REQUEST NUMBER NOTES: 1/4" ODT TUBING BULKHEAD UNION, SWAGELOK SS-400-61 * E-1343 A/R EA 999 FITTING -AS DESCRIBED BELOW: 330-01 ITEM NUMBER - 12-999-0001 REQUEST NUMBER - NOTES! 1/2" ODT TUBING BULKHEAD UNION, SWAGELOK SS-810-61 * E-1345 A/R EA 999 FITTING -AS DESCRIBED BELOW: 330-01 ITEM NUMBER - 12-999-0001 REQUEST NUMBER NOTES: 3/8" DDT X 1/4" DDT REDUCING UNION, SWAGELOK SS-600-6-4 * E-1346 A/R EA 999 FITTING -AS DESCRIBED BELOW: 330-01 ITEM NUMBER - 12-999-0001 REQUEST NUMBER M NOTES: 1/2" DDT X 3/8 DDT REDUCING UNION, SWAGELOK SS-810-6-6 ENGINEERING DESIGN FLORIDA CAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST " RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 46 OF 73 . CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT, ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-1347 A/R EA 999 FITTING -AS DESCRIBED BELOW: 330-01 ITEM NUMBER - 12-999-0001 REQUEST NUMBER NOTES: 1/2" ODT X 112" FNPT CONNECTOR, SWAGELOK SS-810-7-8 * E-1352 `A/R A 999 FITTING -AS DESCRIBED BELOW: 330-01 ITEM NUMBER - 12-999-0001 REQUEST NUMBER NOTES: 3/8" ODT TUBING TEE, SWAGELOK SS-600-3 * E-1353 A/R EA 999 FITTING -AS DESCRIBED BELOW: 330-01 ITEM NUMBER - 12-999-0001 REQUEST NUMBER NOTES: 1/2" ODT TUBING TEE, SWAGELOK SS-810-3 * E-1357 A/R EA 999 FITTING -AS DESCRIBED BELOW: 330-01 ITEM NUMBER - 12-999-0001 REQUEST NUMBER - NOTES: 112" ODT TUBING TEE W/ FEMALE PIPE 1/2" P-NPT SWAGELOK SS-810-3-8TTF * E-1369 A/R fA 999 EITTING-AS DESCRIBED BELOW: 330-01 ITEM NUMBER - 12-999-0001 REQUEST NUMBER NOTES 1/2" ODT xl/2" MNPT ELBOW CONNECTOR, SWAGELOK SS-810-2-8 * E-1373 A/R A 999 FITTING -AS DESCRIBED BELOW: 330-01 ITEM NUMBER - 12-999-0001 REQUEST NUMBER NOTES- 1/2" TUBING FITTING PLUG SWAGELOK SS-810-P * E-1430 A/R EA 999 FITTING -AS DESCRIBED BELOW: 330-01 ITEM NUMBER - 12-999-0001 REQUEST NUMBER NOTES: 1/2" X CLOSE PIPE NIPPLE 316 SS g * E-1514 A/R EA 999 FITTING -AS DESCRIBED BELOW: 330-01 ITEM NUMBER - 12-999-0001 REQUEST NUMBER - \V NOTES: y 1/2" FNPT PIPE TEE, 316SS, 3000# CAJON SS-B-T 0�� ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: 522138 MATERIALS LIST - RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 47 OF 73 CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER- QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-1532 A/R EA 999 FITTING -AS DESCRIBED BELOW: 330-01 ITEM NUMBER - 12-999-0001 REQUEST NUMBER - NOTES: 1/2" HEAVY HEX HEAD PLUG 316SS, 6000#, CAJON SS-B-P * E-1533 A/R EA 999 FITTING -AS DESCRIBED BELOW: 330-01 ITEM NUMBER - 12-999-0001 REQUEST NUMBER NOTES: 1/4" PLASTIC PLUG, CAPLUG SC-1/4-7 * E-1534 A/R EA 999 FITTING -AS DESCRIBED BELOW: 330-01 ITEM NUMBER - 12-999-0001 REQUEST NUMBER NOTES: 3/8" PLASTIC PLUG, CAPLUG SC-3/8-7 * E-1574 A/R EA 999 FITTING -AS DESCRIBED BELOW: 330-01 ITEM NUMBER - 12-999-0001 REQUEST NUMBER'- NOTES: 1/4" SCH. 80 NIPPLE, 316SS, 2 1/2" LONG, TBE. * E-1581 A/R EA 999 FITTING -AS DESCRIBED BELOW: 330-01 ITEMNUMBER- 12-999-0001 REQUEST NUMBER NOTES: 1/2" SCH. 80 NIPPLE, 316SS, CLOSE, TBE. * E-1584 A/R EA 999 FITTING -AS DESCRIBED BELOW: 330-01 ITEM NUMBER - 12-999-0001 REQUEST NUMBER, - NOTES: 1/2" x 3" LONG SCH. 80 NIPPLE, 316SS, TBE * E-1590 A/R EA 999 FITTING -AS DESCRIBED BELOW: 330-01 ITEM NUMBER - 12-999-0001 REQUEST NUMBER - NOTES: 1/2" x 1/4" HEX REDUCING NIPPLE, CAJON SS-8-HRN-4. * E-1594 A/R EA 999 FITTING -AS DESCRIBED BELOW:- 330-01 ,ygAS6 77y ITEM NUMBER 12-999-0001 REQUEST NUMBER e� NOTES: 1/2" SCH. 40 CS PIPE, GALV. TBE.VNX g y or v DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 ENGINEERING PROJEC NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJEC NAME: FGT - STATION #20 PAGE 48 OF 73 . M RK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E- 601 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01 ITEM NUMBER - 33-999-0013 REQUEST NUMBER - NOTES: 1 5/81, x 1 5/81, STRUT, HOT DIP GALVANIZED, UNISTRUT P1000 HG * E 660 A/R EA ELECTRICAL EQUIP. -ELECTRICAL PART 238-01- ITEM NUMBER - 33-999-0013 REQUEST NUMBER NOTES: 1/411-20 UNC SPRING NUT, UNISTRUT P1006-1420 E 700 1 EA. TEMP. SENSOR-ROSEMOUNT MODEL# 0068-PLATINUM 521-01 RESISTANCE TYPE (0068), INSTALLED IN CONNECTION HEAD WITH FLAT COVER, FM APPROVED (F), SINGLE ELEMENT SPRING -LOADED STYLE WITH TEMPERATURE RANGE OF -100 - 400 DEG C (-148 - 752 DEG F) (21), WITHOUT EXTENSION (N), (00), COMPLETE WITH TYPE 316''SST THERMOWELL (A), WITH A 4.5 INCH IMMERSION LENGTH AND AN OVERALL LENGTH OF 6.0 INCHES (045), A TAPERED STEM, AND THREAD MOUNTED, 1" NPT (T28), WITH 303 SST SPRING -LOADED FITTING, 1/211 - 14 NPT (SNN) ITEM NUMBER - 34-081-0071 REQUEST NUMBER - 47 NOTES: FOR USE WITH TEMPERATURE INDICATING CONTROLLER MARK NO. E-1701. THERMOWELL TO BE RATED 3000 PSIG AT 200 DEGREE F. TAG TE-566B STAMP TAG NO. ON FLAT OF THERMOWELL HEX HEAD. (SEE ATTACHED SPEC SHEET #J-20-1A) E- 701 1 EA CONTROL EQUIPMENT -CONTROLLER 521-01 ITEM NUMBER - 30-999-0006 REQUEST NUMBER - 51 NOTES: TEMPERATURE INDICATOR- TRANSMITTER CONTROLLER FOR USE WITH 100 OHM PLATINUM RTD, ADJUSTABLE RANGE 20-200 DEG F. CALIBRATED 4 TO 20 MA OUTPUT FROM 20 TO 200 F. DIGITAL INDICATOR, 24VDC, RATED CLASS 1, Aa - " - DIV 2, GROUP D. WITH WALL MOUNTING BRACKET. Zm To' �� r*'l MOORE CAT. N0. 3446N5N. 9 TAG: TIC-566B (SEE ATTACHED SPEC. SHEET # J-20-1A) By m ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT .NAME: FGT - STATION #20 PAGE 49 OF 73 . CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED E-1702 8 EA. TEMP. SENSOR-ROSEMOUNT MODEL# 0068-PLATINUM 521-01 RESISTANCE TYPE (0068), INSTALLED IN CONNECTION HEAD WITH FLAT COVER, FM APPROVED (F), SINGLE ELEMENT SPRING -LOADED STYLE WITH TEMPERATURE RANGE OF -100 400 DEG C (-148 - 752 DEG F) (21), WITHOUT EXTENSION (N), (00), COMPLETE WITH TYPE 316 SST THERMOWELL (A), WITH A 7.5 INCH IMMERSION LENGTH AND AN OVERALL LENGTH OF 9.0 INCHES (075), A TAPERED STEM, AND THREAD MOUNTED, 111 NPT (T28), WITH 303 SST SPRING -LOADED FITTING, 1/211 - 14 NPT (SNN) ITEM NUMBER - 34-081-0072 REQUEST NUMBER - 47 NOTES: WITH CHAIN AND CAP. PERMANENTLY ATTACHED SS TAG WITH TAG NUMBER IS REQUIRED. STAMP TAG NUMBER ON HEX FLAT OF WELL, FOR ... (TE-503-1), C-2006, CYL.2 SUCT., (TE-503-3), C-2006, CLY.4 SUCT (TE-504-2), C-2006, CYL.1 SUCT. (TE-504-4), C-2006, CYL.3 SUCT. (TE-511-1), C-2006, CYL.2 DISCH. (TE-511-3), C-2006, CYL.4 DISCH. (TE-512-2), C-2006, CYL.1 DISCH. (TE-512-4), C-2006, CYL.3 DISCH. SEE ATTACHED SPEC. SHEET # J-20-ID) E-1703 4 EA. PRESSURE GAUGE -DIFFERENTIAL TYPE, 50-0-50 PSIG, 524-01 GRADUATION OF 1 PSIG, ACCURATE TO WITHIN 1/2% OF FULL RANGE, 2 1/211 DIA. DIAL, 1/211 NPT, STEM MOUNTED WITH BOTTOM CONNECTION, 316 STAINLESS STEEL CASE WITH 316, FOR SWEET GAS SERVICE ITEM NUMBER - 34-060-0028 REQUEST NUMBER - 47 NOTES: STANDARD RANGE 0 TO 50 PSID, SCALE 0 TO 50 PSID, 1200 MAX PSIG OPERATING PRESSURE, BODY RATING 5000 PSIG, MAX TEMPERTURE 110 F. ORANGE RESEARCH 1201PG OR APPROVED EQUAL. PERMANENTLY ATTACHED SS TAG WITH NUMBER AS FOLLOWS. TAG: PDI-501 PDI-2071 PDI-2072 PDI-2073 SEE ATTACHED SPEC. SHEET #J-20-5A.) `R ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: 522138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 50 OF 73 . MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY qCTR FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED E-1704 -1 EA CONTROL EQUIPMENT -SWITCH 150-01 ITEM NUMBER - 30-999-0021 REQUEST NUMBER - 49C1 NOTES DIFFERENTIAL PRESSURE. SET RANGE 0-100 PSID, SCALE 0-100 PSID. PROCESS PRESSURE 0 TO 1250 PSIG. SET a 50 PSID DECREASING TO CLOSE, 4.5" DIAL, TWO SPST REED SWITCHES RATED 50 WATTS AT 24 VDC, WEATHERPROOF, RATED CLASS 1, DIV 2, GROUP D. PRESSURE BEARING PARTS TO BE SS. FOR SWEET NATURAL GAS SERVICE. PERMANENTLY ATTACHED SS TAG WITH NUMBER AS FOLLOW TAG: PDS-514 MFG. ORANGE RESEARCH OR APPROVED EQUAL. (SEE ATTACHED SPEC. SHEET #J-20-5B.) E-1707 1 EA MEASUREMENT EQUIP. -MEASUREMENT EQUIP. 524-01 ITEM NUMBER - 34-999-0004 REQUEST NUMBER - 47 NOTES: TEMPERATURE INDICATOR, 1/2" NPT EVERYANGLE STEM CONNECTION, 316SS STANDARD, SS CASE, 5" DIAL, WHITE, EXTERNAL ADJUSTABLE WITH HERM. SEALED CASE, TEMPERATURE RANGE 200 TO 1000 DEG F. STEM LENGTH ADJUSTED FOR 12" IMMERSION WITH 6" LAGGING, TO INCLUDE 316SS THREADED AND TAPERED THERMOWELL (RATED 1500 PSIG AT 750 F) AND EXTENSION. 1" PROCESS CONNECTION. ASHCROFT MOD.# 50EI-60E OR APPROVED EQUAL. TAG: TI-2083 WITH PERMANENTLY ATTACHED SS TAG WITH NUMBER STAMP TAG # ON HEX FLAT OF THERMOWELL. (SEE ATTACHED SPEC. SHEET #J-20-1B.) �y l;F y xi �1 63 ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PR JECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PR JECT'NAME: FGT - STATION #20 PAGE 51 OF 73 CTR -MARK REQUEST QUANTITY UNIT NO. 'PURCHASE ORDER' QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED E-1709 2 EA ENGINEERED EQUIP -SIGHT GLASS 530-01 ITEM NUMBER - 28-998-0001 REQUEST NUMBER - 50 NOTES: LEVEL GAGE, DANIELS 5/811 O.D. REDLINE TUBULAR GLASS COMPLETE W/ DANIEL WITH 3/411 MNPT TYPE 1T VALVES. FOR JACKET WATER SURGE TANK SERVICE, MIN RATED 160 PSIG AT 170 DEGREE F, TO INCLUDE GUARD RODS AND 1/211 SS DRAIN/ VENT VALVE. LENGTHS AND TAGS AS FOLLOWS: LG-560A 3611 C-C LG-560B 2411 C-C ALL WITH PERMANENTLY ATTACHED SS TAG WITH NUMBER IS REQUIRED. (SEE ATTACHED SPEC. SHEET #J-20-3A.) E-1710 2 EA ENGINEERED EQUIP -SIGHT GLASS 530-01 ITEM NUMBER - 28-998-0001 REQUEST NUMBER - 50 NOTES: LEVEL GAGE, DANIEL 5/811 O.D. REDLINE TUBLAR GLASS COMPLETE WITH DANIEL 3/411 MNPT TYPE 1T VALVES. FOR AUX WATER SURGE TANK SERVICE, MIN RATED 160 PSIG AT 150 DEGREE F, TO INCLUDE GUARD RODS AND 1/211 SS DRAIN/VENT VALVE. LENGTHS AND TAGS AS FOLLOWS. LG-561A 4211 C-C LG-561B 3611 C-C PERMANENTLY ATTACHED SS TAG WITH NUMBER IS REQUIRED. (SEE ATTACHED SPEC. SHEET #J-20-3A.) E-1712 2 EA CONTROL EQUIPMENT, -SWITCH 150-01 ITEM NUMBER - 30-099-0021 REQUEST NUMBER - 49 NOTES: LEVEL, HIGH LEVEL, RATED MIN 1500 PSIG AT 170 DEGREE F. 1 1/211 PROCESS CONNECTIONS, 11211 CONDUIT CONNECTION. FURNISHED WITH ONE DPDT CONTACT SWITCH RATED 5 AMPS AT 24VDC. RATED CLASS 1, DIV. 2, GROUP D. TAG: LSLL-560 LSLL-561 A MURPHY L1100 OR APPROVED EQUAL. y' PERMANENTLY ATTACHED SS TAG WITH NUMBER IS REQUIRED. 20 3B.) (SEE ATTACHED SPEC. SHEET #J ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER• S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT — STATION #20 PAGE 52 OF 73 CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME-SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED E-1713 1 EA MEASUREMENT EQUIP. -MEASUREMENT EQUIP. 524-01 ITEM NUMBER - 34-999-0004 REQUEST NUMBER - 46 NOTES: TEMPERATURE INDICATOR, 20 TO 240 DEGREE F, THREADED, 316 SS STEM, 20- CAPILLARY LENGTH, 9" INSERT LENGTH WITH 316 SS THERMOWELL RATED 3000 PSIG AT 200 DEGREE F, 1" PROCESS CONNECTION. ASHCROFT MODEL # 600A-01—001-B01-A1-L07-AK OR APPROVED EQUAL. TAG: TI-501 PERMANENTLY ATTACHED SS TAG WITH NUMBER IS REQUIRED. STAMP TAG ON HEX FLAT OF WELL. (SEE ATTACHED SPEC. SHEET # J-20-1C) E-1714 1 EA MEASUREMENT EQUIP. -MEASUREMENT EQUIP. 524-01 ITEM NUMBER - 34-999-0004 REQUEST NUMBER - 46 NOTES: TEMPERATURE INDICATOR, 50 TO 300 DEGREE F, THREADED, 316 SS STEM, 20- CAPILLARY LENGTH, 9" INSERT LENGTH, WITH 316 SS THERMOWELL RATED 3000 PSIG AT 300 DEGREE F, 1" PROCESS CONNECTION. ASHCROFT MODEL #600-A01-001-B01-A1 L07-AL OR APPROVED EQUAL ' TAG: TI-514 PERMANENTLY ATTACHED SS TAG WITH NUMBER IS REQUIRED. STAMP TAG ON HEX FLAT OF WELL. (SEE ATTACHED SPEC. SHEET # J-20-1C) a,�Fni� 7 �7T ,y� DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03 ENGINEERING /93 Y ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 54 OF 73 . CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED E-1718 3 EA. THERMOWELL-THREADED CONFIGURATION, 1" NOMINAL PIPE 521-01 DIA. X 1/21' INTERNAL NPT, WITH 4 1/2" THERMOWELL INSERTION LENGTH, 1/2" NOMINAL DIA. BORE, AISI 316 STAINLESS STEEL, TAPERED SHANK, WITH CAP AND CHAIN ITEM NUMBER - 34-086-0032 REQUEST NUMBER - 46 NOTES: RATED 6000 PSIG AT 200 DEGREE ASHCROFT OR APPROVED EQUAL TAG: TW-567 TW-568A TW-568B. (SEE ATTACHED SPEC. SHEET #J-20-lE) E-1721 1 EA TEMP. TRANSMITTER-ROSEMOUNT MODEL#',444 (444), 100 523-01 OHM LINEARIZED OUTPUT TYPE PLATINUM RTD WITH TEMPERATURE SPAN OF 45-135 DEG F (RL1), WITH UPSCALE BURNOUT INDICATION (U), TRIM TO APPLICABLE MODEL 78 CURVE (1), EXPLOSION PROOF HOUSING (A), WITHOUT MOUNTING BRACKET (1), FACTORY MUTUAL (FM) APPROVALS. EXPLOSION PROOF: CLASS 1, DIVISIONS I AND 11, GROUPS B,C, AND D. DUST -IGNITION PROOF: CLASS 11, DIVISIONS I AND 11, GROUPS E,F, AND G. SUITABLE FOR USE IN CLASS 111. (E5) ITEM NUMBER - 34-082-0015 REQUEST NUMBER - 47 NOTES: TO INCLUDE ONE PLATINUM LONG SHEATH RTD WITHOUT THERMOWELL, 100 OHM, 4 WIRE, 84 "' LONG WITH COMPRESSION FITTING AS REQUIRED TO CONNECT TO THE ABOVE. ROSEMOUNT MOD# 0088N81ENOON-84 TAG: TT-523 PERMANENTLY ATTACHED SS TAG WITH NUMBER IS REQUIRED. (SEE ATTACHED SPEC. SHEET# J-20-1F) �s. 4 ` v "Y ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: 522138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 55 OF 73 . CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED E-1722 4 EA PRESSURE XMTR-ROSEMOUNT MODEL 2088G GAGE PRESSURE 523-01 TRANSMITTER, 0-666 TO 0-4000 PSI RANGE (4), 4-20 MA DC OUTPUT (A), 316 SST PROCESS CONNECTION, 316 SST ISOLATING DIAPHRAGM, SILICONE OIL FILL (22), 1/2 NPT FEMALE PROCESS CONNECTION (A), 1/2 NPT CONDUIT THREAD (1), SST MOUNTING BRACKET WITH SST BOLTS (64), FACTORY MUTUAL (FM) EXPLOSION PROOF APPROVAL (E5), NOT APPLICABLE ITEM NUMBER - 34-062-0109 REQUEST NUMBER - 47 NOTES: TAG: PT-501 PT-514 PT-201A PT-2018 SET RANGE SHALL BE CALIBRATED a 0-1500 PSIG W/ FACTORY FURNISHED CERTIFICATE. PERMANENTLY ATTACHED SS TAG W/ NUMBER IS REQUIRED. (SEE ATTACHED SPEC. SHEET #J-20-4A.) E-1725 1 EA PRESSURE GAUGE -STANDARD, 0 - 500 PSIG, GRADUATION OF 524-01 5 PSIG, ACCURATE TO WITHIN 1% OF FULL RANGE, 4 1/2" DIA. DIAL, 1/2" NPT, STEM MOUNTED WITH BOTTOM CONNECTION, FIBERGLASS REINFORCED POLYPROPYLENE CASE WITH 316 STAINLESS STEEL INTERNALS, FOR SWEET GAS SERVICE ITEM NUMBER - 34-060-0012 REQUEST NUMBER - 46 NOTES: TAG: PI-2070 OPERATING PRESSURE 300 PSIG_ MFR. ASHCROFT MOD# 45-1279. PERMANENTLY ATTACHED SS TAG WITH NUMBER IS REQUIRED. (SEE ATTACHED SPEC. SHEET #J-20-4B.) �k - r - I a., ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 - PAGE 56 OF 73 . CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED rFUR E-1726 2 EA. PRESSURE GAUGE -STANDARD, 0 - 300 PSIG, GRADUATION OF 524-01 2 PSIG, ACCURATE TO WITHIN 1/2% OF FULL RANGE, 4 1/211 DIA. DIAL, LIQUID FILLED, 1/2" NPT, STEM MOUNTED WITH BOTTOM CONNECTION, FIBERGLASS REINFORCED POLYPROPYLENE CASE WITH 316 STAINLESS STEEL INTERNALS, FOR SWEET GAS SERVICE ITEM NUMBER - 34-060-0029 REQUEST NUMBER - 46 NOTES: TAG: PI-2061 PI-2069 AT OPER. PRESS. 200; MFR.ASHCROFT MOD# 45-1279. PERMANENTLY ATTACHED SS TAG WITH NUMBER IS REQUIRED. (SEE ATTACHED SPEC. SHEET #J-20-4B.) E-1727 2 EA. PRESSURE GAUGE -STANDARD, 0 - 160 PSIG, GRADUATION OF 524-01 1 PSIG, ACCURATE TO WITHIN 1/2% OF FULL RANGE, 4 1/211 DIA. DIAL, LIQUID FILLED, 1/2" NPT, STEM MOUNTED WITH BOTTOM CONNECTION, 316 STAINLESS STEEL CASE WITH 316, FOR SWEET GAS SERVICE ITEM NUMBER - 34-060-0004 REQUEST NUMBER - 46 NOTES: TAG: PI-2012 OPERATING PRESS 100 PSIG. TAG: PI-2022 OPERATING PRESS 50 PSIG MFR. ASHCROFT MOD #45-1279 PERMANENTLY ATTACHED SS TAG WITH NUMBER IS REQUIRED. (SEE ATTACHED SPEC. SHEET #J-20-4B.) E-1733 1 EA CONTROL EQUIPMENT-dONTROLLER 192-01 ITEM NUMBER - 30-999-0006 REQUEST NUMBER - 19 NOTES: S460 EIGHT (8) ZONE UV/IR FIRE (FLAME) DETECTOR CONTROLLER WITH FORM "C11 RELAY OUTPUT ASSEMBLY. 24/h VDC. MFR. DET-TRONICS ER. MOD# R6007 A1006 RELAY ASSEMBLY TAG UNIT: JFC-2003 PERMANENTLY ATTACHED SS OR LAMINATED PLASTIC TAGS WITH NUMBERS ARE REQUIRED ON FACE OF CONTROLLER. ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 57 OF 73 , CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY !'QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED E-1734 4 EA CONTROL EQUIPMENT -FIRE DETECTOR 192-01 ITEM NUMBER - 30-999-0008 REQUEST NUMBER - 19 NOTES: FLAME DETECTORS- UV/IR. FOR USE IN CLASS 1, GROUP D, DIVISION 1 AREAS. FURNISH WITH STANDARD ALUMINUM HOUSING FOR DIRECT MOUNTING ON 3/4" CONDUIT. MFR. DET-TRONICS MOD# C7052 J5000. TAG: JFD-2003A rJFD-20038 JFD-2003C JFD-2003D PERMANENTLY ATTACHED SS TAG WITH NUMBER IS REQUIRED. E-1735 1 EA CONTROL EQUIPMENT -CONTROLLER 192-01 ITEM NUMBER - 30-999-0006 REQUEST NUMBER - 19 NOTES: EIGHT CHANNEL SCANNING GAS DETECTOR MONITOR COMPLETE WITH HIGH & LOW EXPLOSIVE LIMIT OUTPUT RELAYS. FURNISH UNIT FOR 24 VDC. THE UNIT WILL PROVIDE POWER TO DETECTORS AND MONITOR EACH EQUIPPED WITH CALIBRATION TRANSMITTERS. UNITS SHALL BE COMPLETE RELAY BOARDS AS REQUIRED TAG. JGC!2003. MFR. DET-TRONICS MOD#'226650-001 MONITOR/CONTROLLER PERMANENTLY ATTACHED SS TAG OR LAMINATED PLASTIC TAGS ARE REQUIRED ON FRONT OF MONITOR. 3 4 tV� I E4 4z Z >� ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PAGE 58 OF 73 . PROJECT NAME: FGT - STATION #20 CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED E-1736 4 EA CONTROL EQUIPMENT -GAS DETECTOR 192-01 ITEM NUMBER - 30-999-0009 REQUEST NUMBER - 19 NOTES: COMBUSTIABLE GAS DETECTOR HEADS W/ ALUMINUM HOUSING MOUNTED ON AN EXPLOSION PROOF J-BOX FOR USE IN A CLASS 1 DIVISION 1 GROUP D AREA. ALL SENSORS CALIBRATION TRANSMITTER FOR USE W/ DETECTOR ELECTRONICS MODEL 8000 EIGHT CHANNEL MONITOR. ALL SENSORS WITH JUNCTION BOX SUPPLY TWO SENSORS (JDG-2003A AND JDG-2003B) WITH REMOTE CALIBRATION KITS. MFR. DIET-TRONICS MOD# 226530-001 FOR DETECTOR HEAD. MOD# 226555-001 FOR J-BOX MOD# 226585-001 FOR 500/1K TRANSMITTER. MOD# 226585-002 FOR REMOTE KIT TAG: JGD-2003A JGD-2003B JGD-2003C JGD-2003D PERMANENTLY ATTACHED SS TAG WITH NUMBER 1S REQUIRED ON EACH J-BOX. E-1737 1 EA CONTROL EQUIPMENT -CONTROLLER 192-01 ITEM NUMBER - 30-999-0006 REQUEST NUMBER - 19 NOTES: SINGLE CHANNEL GAS DETECTOR TRANSMITTER CONTROLLER COMPLETE WITH INDEPENTLY ADJUSTABLE THRESHOLD ALARM OUTPUT CONTACTS RATED AT 1 AMPERE a 24VDC. FURNISH ALUMINUM ENCLOSURE SUITABLE FOR CLASS 1 GROUP D DIVISION 1 HAZARDOUS AREA. PROVIDE SENSOR AND SENSOR SEPERATION KIT. MFR: DET-TRONICS TRANSMITTER / CONTROLLER : #U8700H 7147 / pp SENSOR : #226530-003., SEPARATION KIT : #226365-006� 19 a TAG JGD AUX.� PERMANETLY ATTACHED SS TAG WITH NUMBER IS REQUIRD ONE EACH J-BOX.' �L� ENGINEERING DESIGNI FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 59 OF 73 TR fFU MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY R NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED E-1742 1 EA CONTROL EQUIPMENT -SOLENOID VALVE 150-01 ITEM NUMBER - 30-999-0023 REQUEST NUMBER - 52 NOTES: INSTRUMENT AIR SERVICE, 150 PSIG, BRASS BODY W/ SS SEAT. 1/211 BODY, 5/811 PORT, THREE WAY. CLASS F COIL, 24 VDC, APPROVED FOR CLASS 1 DIV 1 GROUP D. TAG: SDV-2050 MFR. ASCO MOO# EF8316G OR APPROVED EQUAL PERMANENTLY ATTACHED SS TAG WITH NUMBER IS REQUIRED. (SEE ATTACHED SPEC. SHEET #J-20-6A) E-1752 1 EA MEASUREMENT EQUIP -REGULATOR - 1" OR LARGER 150-01 ITEM NUMBER - 34-998-0007 REQUEST NUMBER - 53 NOTES: PRESSURE REDUCING CONTROL REGULATOR -CRANE INSTRUMENT AIR SERVICE. MAXIMUM INLET 270 PSIG BY 100 PSIG SET PRESSURE. BODY SIZE - 111, PORT SIZE - 9/16", 1" FNPT END CONNECTION, CARBON STEEL BODY MATERIAL, SS 'TRIM. TAG: PCV-2061 MFR, FISHER MOD# 95H, PERMANENTLY ATTACHED SS TAG WITH NUMBER IS REQUIRED. (SEE ATTACHED SPEC. SHEET #J-20-14A) E-1755 1 EA MEASUREMENT EQUIP -REGULATOR - 1" OR LARGER 150-01 ITEM NUMBER - 34-998-0007 REQUEST NUMBER - 53 NOTES: PRESSURE REGULATOR,- AIR SERVICE FOR TURBO ASSIST MAXIMUM INLET 270 PSIG BY A SETPOINT AT 135 PSIG. 1" BODY SIZE. PORT SIZE - 100%, 1" NPT END CONNECTION. WCB STEEL BODY MATERIAL. 8 7$'qdG TAG: PCV-2069 kI's MFR. FISHER MOD# 310-1.� PERMANENTLY ATTACHED SS TAG WITH NUMBER IS REQUIRED. n( (SEE ATTACHED SPEC. SHEET #J-20-14A) b�',e , b VEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 ENG PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 60 OF 73 CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED E-1756 1 EA VALVE -RELIEF 930-00 ITEM NUMBER - 17-999-0014 REQUEST NUMBER - 54 NOTES: AIR RECEIVER, INSTRUMENT AIR SERVICE, SET PRESSURE AT 270 PSIG. INLET SIZE: 1" FNPT OUTLET SIZE: 1" FNPT CARBON STEEL BODY, SS TRIM, 0-RING SEAT, .196 "E" ORIFICE. VENDOR TO SPECIFY CAPACITY AVAILABLE. TAG: PSV-2070 MFR. AGCO MOD# 83C-88-8 OR APPROVED EQUAL PERMANENTLY ATTACHED SS TAG WITH NUMBER IS REQUIRED. (SEE ATTACHED SPEC. SHEET #J-20-16A) VALVE TO BE DESIGNED, MANUFACTURED, TESTED AND INSPECTED IN ACCORDANCE WITH ENRON ES 4410, LATEST REVISION E-1757 1 EA VALVE -RELIEF 930-00 ITEM NUMBER - 17-999-0014 REQUEST NUMBER --54 NOTES: CRANE AIR SUPPLY. INSTRUMENT AIR SERVICE. SET PRESSURE 115 PSIG,', REQUIRED CAPACITY 679 SCFM AT 165 MAX INLET. INLET SIZE - 1-1/2" ANSI 150 RF FLANGE OUTLET SIZE - 2" ANSI 150 RF FLANGE CARBON STEEL BODY, SS TRIM, "G" ORIFICE (.503 SO 1N) 0-RING SEAT. (VENDOR TO SPECIFY ORIFICE CAPACITY). TAG: PSV-2061 MFR.AGCO MOD# 83C-05G-152 OR APPROVED EQUAL PERMANENTLY ATTACHED SS TAG WITH NUMBER IS REQUIRED, 4EiCa f, (SEE ATTACHED SPEC. SHEET #J-20-16A) r VALVE TO BE DESIGNED, MANUFACTURED, TESTED AND INSPECTED IN ACCORDANCE WITH ENRON ES 4410, LATEST ED, REVISION REEL 4 DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 ENGINEERING PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 61 OF 73 . C R MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED E-1758 1 EA VALVE -RELIEF 930-06 ITEM NUMBER - 17-999-0014 REQUEST NUMBER - 54 NOTES: UNIT DISCHARGE, .58 SG NATURAL GAS SERVICE, SET PRESSURE AT 1015 PSIG. INLET SIZE : 6" ANSI 600 RF. OUTLET SIZE: TWO (2) 8" ANSI 150 RF. BODY - CARBON STEEL. SS TRIM, NON BLEED PILOT, MODULATING RATED FOR 416 MSCFM AT 120 DEGREE F. VENDOR TO VERIFY SIZING AND SPECIFY ORIFCE AREA. MFR. AGCO MOD# 47312-688/S1 TAG: PSV-517 PERMANENTLY ATTACHED SS TAG WITH NUMBER IS REQUIRED. (SEE ATTACHED SPEC. 'SHEET #J-20-16A) VALVE TO BE DESIGNED, MANUFACTURED, TESTED AND INSPECTED IN ACCORDANCE WITH ENRON ES 4410, LATEST REVISION E-1759 1 EA VALVE -RELIEF 930-02 ITEM NUMBER - 17-999-0014 REQUEST NUMBER -_54 .NOTES:. JET ASSIST AIR SUPPLY. SET PRESSURE AT 145 PSIG. INLET SIZE -2" ANSI 150 RF OUTLET SIZE - 3" ANSI 150 RF CARBON STEEL BODY, SS TRIM, "J" ORIFICE, 0-RING SEAT. .VENDOR TO SPECIFY AVAILABLE CAPACITY. TAG: PSV-2069 MFR. AGCO MOD# 83-05J-2-3 OR APPROVED EQUAL 8a ���13'� PERMANENTLY ATTACHED SS TAG WITH NUMBER IS REQUIRED. �Y (SEE ATTACHED SPEC. SHEET #J-20-16A) VALVE TO BE DESIGNED, MANUFACTURED, TESTED AND y INSPECTED IN ACCORDANCE WITH ENRON ES 4410, LATEST REVISION,, 2 s ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: 522138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 62 OF 73 . CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED E-1768 1 EA CONTROL EQUIPMENT -SWITCH 150-01 ITEM NUMBER - 30-999-0021 REQUEST NUMBER - 49 NOTES: PRESSURE, SETTING AS LISTED BELOW BY FACTORY, INTERNALLY ADJUSTABLE, SS DIAPHRAGM, 1/2" FNPT PROCESS CONNECTION, SURFACE MOUNTING, SNAP ACTION, DPDT RATED 24 VDC AT 5 AMPS FOR CLASS 1, DIV. 2, GROUP D W/ 1/2" NPT CONDUIT CONNECTION. ALL PRESSURE BEARING PARTS TO BE STAINLESS STEEL. FOR SWEET NATURAL GAS SERVICE. MFR. CCS, STATIC-O-RING OR APPROVED EQUAL. LOW PRESSURE SHUTDOWN PRESSURE RANGE 200 TO 1700 PROCESS RANGE: 650 TO 750 PSIG SET POINT: 400 PSIG DECREASING DEAD BAND: (MANUFACTOR SPECIFY) TAG: PSLL-501 PERMANENTLY ATTACHED SS TAG WITH NUMBER IS REQUIRED. (SEE ATTACHED SPEC. SHEET #J-20-4C) E-1769 1 EA CONTROL EQUIPMENT -SWITCH 150-01 ITEM NUMBER - 30-999-0021 REQUEST NUMBER - 49 NOTES: PRESSURE, SETTING AS LISTED BELOW BY FACTORY, INTERNALLY ADJUSTABLE, SS DIAPHRAGM, 1/2" FNPT PROCESS CONNECTION, SURFACE MOUNTING, SNAP ACTION, DPDT RATED 25 VDC AT 5 AMPS FOR CLASS 1, DIV. 2, GROUP D W/ 1/2" NPT CONDUIT CONNECTION. ALL PRESSURE BEARING PARTS TO BE STAINLESS STEEL. FOR SWEET NATURAL GAS SERVICE. MFR. CCS, STATIC-0-RING OR APPROVED EQUAL. HIGH PRESSURE SHUTDOWN PRESSURE RANGE 200 TO 1700 PROCESS RANGE: 900 TO 980 PSIG SET POINT: 1000 PSIG INCREASING DEAD BAND: (MANUFACTOR SPECIFY) TAG: PSHH-514 r`{ PERMANENTLY ATTACHED SS TAG WITH NUMBER IS REQUIRED. (SEE ATTACHED DATA SPEC. SHEET #J-20-4C) t: 'I FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 ENGINEERING DESIGN PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME. 16:41:32 PROJECT NAME: FGT —STATION #20 PAGE 63 OF 73 . CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED E-1770 I EA- CONTROL EQUIPMENT -SWITCH 150-01 ITEM NUMBER - 30-999-0021 REQUEST NUMBER - 49 NOTES: PRESSURE, SETTING AS LISTED BELOW BY FACTORY, INTERNALLY ADJUSTABLE, SS DIAPHRAGM, 1/2" FNPT PROCESS CONNECTION, SURFACE MOUNTING, SNAP ACTION, DPDT RATED 24 VDC AT 5 AMPS FOR CLASS 1, DIV. 2, GROUP D W/ 1/2" NPT CONDUIT CONNECTION. ALL PRESSURE BEARING PARTS TO BE STAINLESS STEEL. FOR HYDROLIC OIL SERVICE. MFR. CCS, STATIC-0-RING OR APPROVED EQUAL. HYDROLIC SYSTEM LOW PRESSURE PRESSURE RANGE 4 TO 75 PSIG PROCESS RANGE: 10 TO 60 PSIG SET POINT: 10 PSIG DECREASING DEAD BAND: NARROW (MANUFACTOR SPECIFY) TAG: PSLL-2073 PERMANENTLY ATTACHED SS TAG WITH NUMBER IS REQUIRED. (SEE ATTACHED SPEC. SHEET #J-20-4C) E-1771 1 EA CONTROL EQUIPMENT -SWITCH 150-01 ITEM NUMBER - 30-999-0021 REQUEST NUMBER - 49 NOTES: PRESSURE, SETTING AS LISTED BELOW BY FACTORY, INTERNALLY ADJUSTABLE, SS DIAPHRAGM, 1/2" FNPT PROCESS CONNECTION, SURFACE MOUNTING, SNAP ACTION, DPDT RATED 24 VDC AT 5 AMPS FOR CLASS 1, DIV. 2, GROUP D W/ 1/2" NPT CONDUIT CONNECTION. ALL PRESSURE BEARING PARTS TO BE STAINLESS STEEL. MFR. CCS, STATIC-O-RING OR APPROVED EQUAL. ESO INTERFACE SWITCH PRESSURE RANGE: 15 TO 100 PSIG 67 PROCESS RANGE: SAME SET POINT: 50 PSIG DECREASING DEAD BAND: NARROW (MANUFACTOR SPECIFY) TAG: PSLL 2050 t�0 1 �' PERMANENTLY ATTACHED SS TAG WITH NUMBER IS REQUIRED.`ab `�EZ21�m (SEE ATTACHED SPEC. SHEET #J-20-4C) ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: 522138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 64 OF 73 CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DES RIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED E-1772 1 EA CONTROL EQUIPMENT -SWITCH 150-01 ITEM NUMBER - 30-999-0021 REQUEST NUMBER - 49 NOTES: PRESSURE, SETTING AS LISTED BELOW BY FACTORY, INTERNALLY ADJUSTABLE, SS DIAPHRAGM, 1/2" FNPT PROCESS CONNECTION, SURFACE MOUNTING, SNAP ACTION, DPDT RATED 125 VAC AT S AMPS. FOR CLASS 1, DIV 2, GROUP D, W/ 1/2" NPT CONDUIT CONNECTION. ALL PRESSURE BEARING PARTS TO BE STAINLESS STEEL. FOR SWEET NATURAL GAS SERVICE. MFR. CCS, STATIC-O-RING OR APPROVED EQUAL. FAN CONTROL PRESSURE RANGE: 15 TO 300 PSIG PROCESS RANGE: 900 TO 980 PSIG (1200 MAX) SET AT 60 PSIG INCREASING DEAD BAND: (MANUFACTOR SPECIFY) TAG: PSH-514A PERMANENTLY ATTACHED SS TAG WITH NUMBER IS REQUIRED. (SEE ATTACHED SPEC. SHEET #J-20-4C) E-1774 >' 1 EA ENGINEERED EQUIP. -ENGINEERED EQUIPMENT 150-01 ITEM NUMBER - 28-999-0006 REQUEST NUMBER - 55 NOTES: LIQUID TRAPS, CARBON STEEL BODY. 3/4" FNPT INLET BY 3/4" FNPT OUTLET BY 3/4" VENT SS TRIM. ALL RATED a 1000 PSIG , 100 DEG. F. ORIFICE SIZE - 5/32". AIR RECEIVER DRAIN. WORKING PRESSURE 350 PSIG AT 100 F AIR AND WATER TAG: LCV-2070 MFR. ARMSTRONG MOD# 33-LD OR APPROVED EQUAL. PERMANENTLY ATTACHED SS TAG WITH NUMBER IS REQUIRED. (SEE ATTACHED SPEC. SHEET #J-20-13A) I LL' 1 J ENGINEE ING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 65 OF 73 . CTR MA K REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUM ER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED E-1775 1 EA 999 FITTING -AS DESCRIBED BELOW: 530-01 ITEM NUMBER - 12-999-0001 REQUEST NUMBER - 56 NOTES: RESTRICTION ORIFICE UNION, FOR SERVICE AIR TO BARRING JACK CONCENTRIC PLATES W/ PLATE TAB, ISA STANDARD, 316 SS, BORE TO NEAREST 1/811. 3000# UNION, CARBON STEEL BODY, 1" F14PT CONNECTION. ORIFICE BORE, 1/2" LINE I.D.- 0.95711 PLATE THICKNESS - 1/811. TAG: RO-2067 PERMANENTLY ATTACHED SS TAG WITH NUMBER IS REQUIRED. (SEE ATTACHED SPEC. SHEET #J-20-2A) E-1776 1 EA 999 FITTING -AS DESCRIBED BELOW: 530-01 ITEM NUMBER - 12-999-0001 REQUEST NUMBER - 56 NOTES: RESTRICTION ORIFICE PLATE, CONCENTRIC W/ PLATE TAB, ANSI 60ORF. 800 PSIG INLET BY 45 PSIG MIN. FOR UNIT PURGE LINE, NATURAL GAS SERVICE. MOUNTING BETWEEN TWO VALVES. ORIFICE BORE DIAMETER = 1.2511 BETA = D/D .6447" LINE I.O. = 1.939" PLATE THICKNESS = 1/811: TAG: RO-502 PERMANENTLY ATTACHED SS TAG WITH NUMBER IS REQUIRED. (SEE ATTACHED SPEC. SHEET #J-20-2A) I r t :; e JF GC ! 811 J� ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 66 OF 73 . CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED E-1777 1 EA 999 FITTING -AS DESCRIBED BELOW: 530-01 ITEM NUMBER - 12-999-0001 REQUEST NUMBER - 56 NOTES: RESTRICTION ORFICE PLATE - FOR STATION FUEL GAS MEASUREMENT, AGA STANDARD. BETA = D/DO .570" ORIFICEE BORE - 1.750" DIA. LINE I.D. - 3.068" PLATE THICKNESS 1/8". TAG: FE-2052 PERMANENTLY ATTACHED SS TAG WITH NUMBER IS REQUIRED. (SEE ATTACHED SPEC. SHEET # J-20-2B) * E-1837 A/R EA U-BOLT-3/8" DIA., BY 2' 1/2" WIDE, W/ 4 HEX HEAD NUTS 952-01 ITEM NUMBER - 15-090-0028 REQUEST NUMBER - NOTES: 3/8"-16 UNC U-BOLT FOR 2" NOM. PIPE, COMPLETE w/ (4) HEAVY HEX HEAD NUTS, WASHERS, AND HOT DIP GALVANIZED * E-1855 A/R EA 999 FASTENER -AS DESCRIBED BELOW: 952-01 ITEM NUMBER - 15-999-0001 REQUEST NUMBER NOTES: 1/4" SPLIT LOCK WASHER, GALV. CS. * E-1863 A/R EA 999 FASTENER -AS DESCRIBED BELOW: 952-01 ITEM NUMBER - 15-999-CIOOI REQUEST NUMBER - NOTES: 1/4" -20 UNC x 1 3/4" LONG, HEX HEAD MACHINE BOLT, GALV. CS. * E-1970 A/R EA BLDG MATLS-STRUCTURAL STEEL 086-01 ITEM NUMBER - 75-999-CIO13 REQUEST NUMBER NOTES: STRUCTURAL CHANNEL, C3 x 5.0 GALV. CS. DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 ENGINEERING PR JECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 67 OF 73 . CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED E-2500 1 EA ELECTRICAL EQUIP -GENERATOR SET 045-01 ITEM NUMBER - 33-998-0001 REQUEST NUMBER - 24 NOTES: GENERATOR SET, STANDBY, SOUTHERN PLAINS POWER (SPP) MODEL 30OGTA19, NATURAL GAS ENGINE DRIVEN, RATED 300 KW, 375 KVA, AT 0.8 PF, 277/480 VAC, 3 PHASE, 4 WIRE, 60 HERTZ, 1800 RPM. ALL RATINGS ARE BASED ON 100 DEGREE AMBIENT F AND INCLUDE THE FAN LOAD. GENERATOR SET TO BE IN ACCORDANCE WITH ENRON INQUIRY RFQ-GENERATOR SETS, DATED JUNE 29, 1993. UNIVERSAL ENSCO, INC. SPECIFICATION UEI #1684-P-02-20, DATED 5/7/93, REV. 0, SPP QUOTATION DATED JULY 19, 1993, REBID QUOTATION DATED AUGUST 26, 1993, LETTERS DATED AUGUST 27, 1993 AND SEPTEMBER 10, 1993, AND SEPTEMBER 28, 1993 AND WITH THE FOLLOWING ADDITIONS: 1. NON -SELECTIVE ENGELHARD CATALYTIC CONVERTOR, MEI EXHAUST EXPLOSION PRESSURE RELIEF ASSEMBLY AND STUB, AND MEI AIR/FUEL RATIO CONTROLLERS AND INSTRUMENTATION. COMPLETE SYSTEM WARRANTY TO MEET THE EMISSIONS SPECIFICATIONS WITHIN THE ORIGINAL SPECIFICATIONS AND AS CLARIFIED BY SPP SEPT. 3, 1993 AND GTA19 REV "A" DATED OCTOBER 19, 1993 AS DEFINED BY MEI PERFORMANCE WARRANTY OF AUGUST 16, 1993. 2. UNIT CONTROLS PER THE RE -BID OF AUGUST 26, 1993, SPP LETTER OF SEPT. 3, 1993, AND MAIN CIRCUIT BREAKERS PER SPP FAX OF SEPT, 9, 1993. 3. SPP SECOND CUT REGULATOR RELIEF SET AT 100 PSIG. 4. SHOP EMISSION TEST OF EACH UNIT WITH ITS CATALYTIC CONVERTOR AND CONTROLS. TESTING PROCEDURES AND A TEST FUEL ANALYSIS TO BE SUBMITTED I IN WRITING TO ENRON 30 DAYS PRIOR TO TESTING FOR COMPANY APPROVAL. SPP WILL NOTIFY ENRON 7 WORKING DAYS IN ADVANCE OF THE ACTUAL TEST DATE. 6 5. WEATHER TIGHT GRAVITY LOUVERS WITH LIP All Al SEALING FLANGE FOR THE FRONT OF THE RADIATOR. LOVERS TO BE SHIPPED LOOSE TO SITE. w 6. HOSPTIAL GRADE EXHAUST SCILENCER. INLET CONFIGURATION TO BE FINALIZED BY ANNOTATION TO E6. APPROVAL DRAWINGS. a fi ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PAGE 68 OF 73 PROJECT NAME: FGT - STATION #20 UNIT N0. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY MARK REQUEST QUANTITY NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED F E-2509 1 EA ELECTRICAL EQUIP. -ELECTRICAL EQUIPMENT ITEM NUMBER - 33-999-0011 REQUEST NUMBER - 74 NOTES: ATS CONTROL MODULES, LABOR AND MATERIAL TO INSTALL THE FOLLOWING WITHIN A GE 8000 MCC ENCLOSURE HOUSING AN ASCO 940 SYSTEM. OPTION 37 "LOAD DISCONNECT CONTROL" OPTION 11C "AUTOMATIC ENGINE EXCERISER" r LY j �t �'� pZ z � DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 ENGINEERING PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 69 OF 73 C R MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FIR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED E-2510 1 EA ELECTRICAL EQUIP -MOTOR CONTROL CENTER 236-01 ITEM NUMBER - 33-998-0004 REQUEST NUMBER - 71 NOTES: FURNISH ALL ENGINEERING, DESIGN, MATERIAL, LABOR AND EQUIPMENT NECESSARY TO FABRICATE A MOTOR CONTROL CENTER IN ACCORDANCE WITH ENRON INQUIRY, DATED JUN 30, 1993, GENERAL ELECTRIC SUPPLY COMPANY QUOTATION DATED JUL 21, 1993 AND AS AMENDED BY LETTER DATED SEP 13, 1993 MOTOR CONTROL CENTER SHALL INCLUDE THE FOLLOWING: 1. ATS/MCC LINE UP 480 VAC, 3 PHASE, 4 WIRE, 60 HERTZ, NEMA 1B. 800 AMP ATS RATED AND PER COMPLIANCE WITH LEI SPECIFICATION #1684-P-04-20 DATED APR 29, 1993. MCC SECTIONS RATED AND IN ACCORDANCE WITH UEI SPECIFICATION #1684-P-03-20 DATED MAY 17, 1993 2. PANEL METERING AND ATS LUGS IN ACCORDANCE WITH ATS SPECIFICATIONS AND ATS SWITCH PANEL ONE -LINE DIAGRAM. SECTION TO INCLUDE ONE (1) ASCO 940 GROUP 7 MICROPROCESSOR BASED TRANSFER SWITCH WITH OPTIONS IN ACCORDANCE WITH SPECIFICATIONS 3. MCC SECTIONS, STARTERS AND BREAKERS TO BE IN ACCORDANCE WITH SPECIFICATIONS FOR MCC SECTIONS AND ONE -LINE DIAGRAM 4. MCC AND ATS TO BE INTERCONNECTED AND BRACED FOR 42000 AMPS SYMETRICAL BY VENDOR WITH CABLE AND LUGS IN ACCORDANCE WITH MCC AND ATC SPECIFICATIONS AND ONE -LINE DIAGRAM 5. SPECIFICATIONS MODIFIED TO ALLOW STANDARD WIRE MARKERS. VERTICAL BUSS TO BE 600 AMPS. DELETE BUSS SHRINK WRAP INSULATION 6. ENTRY ACESS IN ACCORDANCE WITH DRAWING #120.35.620 REVISION 11/23/93 7. MAIN BREAKER REVISED TO MARK NO. E-0790 AND " MOVED EXTERNAL TO MCC. BREAKER TO SERVE AS STATION SERVICE ENTRANCE AND MAIN DISCONNECT. B. PER GE SUPPLY REVISION LETTER OF 11/18/93 {'�y MCC AND ATS SECTIONS TO INCLUDE A 600 AMP RATED \;iw NEUTRAL. !7 i ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT'- STATION #20 PAGE 70 OF 73 . CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED CONTINUED E-2511 1 EA ELECTRICAL EQUIP -SWITCH GEAR 826-01 ITEM NUMBER - 33-998-0007 REQUEST NUMBER - 69 NOTES: FURNISH ALL ENGINEERING, DESIGN, MATERIAL, LABOR AND EQUIPMENT NECESSARY TO FABRICATE A WEATHER PROOF MOTOR CONTROL CENTER IN ACCORDANCE WITH THE ENRON INQUIRY, DATED OCTOBER 21, 1993, PER GENERAL ELECTRIC SUPPLY QUOTATION DATED NOVEMBER 11, 1993, AND AS DEFINED BY UEI SPECIFICATIONS AND AMMENDED BY LETTERS AND DATES TO FOLLOW. THE 480 VAC, 3 PHASE, MOTOR CONTROL CENTER SHALL CONSIST OF A GE 8000 SERIES MCC IN A HEAVY DUTY NEMA 3R ENCLOSURE. MCC SECTIONS, STARTERS, AND BREAKERS WILL BE IN COMPLIANCE WITH UEI SWITCH RACK SPECIFICATIONS #1684-P-05-20 DATED 10/7/93, AS MODIFIED TO A WEATHER PROOF ENCLOSURE BY LETTER ATTACHED TO UEI SPECIFICATIONS DATED OCTOBER 18, 1993, AND WITH CORRECTIONS TO VENDORS ON HEATER LOAD DATED NOVEMBER 3, 1993. MCC STARTER INTERLOCKS WILL BE IN COMPLIANCE WITH THE REFERENCED SPECIFICATION. 2B WIRING WILL BE REQUIRED FOR INTERLOCKS ONLY. MAIN SWITCH DISCONNECTS FOR EACH RACK WILL BE REVISED TO A MOLDED CASE BREAKER. PER LETTER DATED NOVEMBER 22, 1993, THE 30 KVA TRANSFORMER PROPOSED WITHIN THE MCC WILL BE RELOCTED EXTERNAL TO THE HOUSING AND RERATED NEMA 3R. THE MCC BLANK SECTION HOUSING THE TRANSFORMER WILL REMAIN FOR FUTURE EXPANSION. y TAG: SWITCH RACK NO. 4 r�yP c' DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE:,12/03/93 ENGINEER'NG PROJECT UMBER: S22138 MATERIALS LIST RUN TIME:'16:41:32 PROJECT AME: FGT - STATION #20 PAGE 71 OF 73 . CTR MAR REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMB R AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED E-25 0 1 EA ELECTRICAL EQUIP-UNINTERRUPTIBLE POWER SUPPLY 238-01 ITEM NUMBER - 33-998-0008 REQUEST NUMBER - 70 NOTES: 3.6 KVA/ 3 KW FOR 28 MINUTES. DELTEC MODEL 2036CT-3 INCLUDING INTERNAL BATTERY SET. TO INCLUDE: TERMINAL BLOCKS FOR ONE 240/120 VAC IN AND OUT. FOUR (4) NEMA 120 VAC OUTPUT RECEPTACLES. EXTERNAL BATTERY CONNECTOR. SIX (6) 25 AH BATTERIES AND EXTERNAL CABINET. HEAVY DUTY CASTERS WITH LEVELING FEET. SIX (6) SETS OF INSTALLATION AND MAINTENANCE INSTRUCTIONS. * E-25�7 1 EA SAFETY EQUIP/SUPPLY-SAFETY EQUIP/SUPPLY 192-01 ITEM NUMBER - 77-999-0006 REQUEST NUMBER - NOTES< SIGNAL HORN; 24 VDC, 30 WATTS, 93 DB AT 10 FT. RATED FOR CLASS 1 DIVISION 2 GROUP D HAZARDOUS AREAS. CROUSE-HINDS TYPE ETH 2416 OR EQUAL. * E-25'8 2 EA CONTROL EQUIPMENT -ANNUNCIATOR 150-01 ITEM NUMBER - 30-999-0004 REQUEST NUMBER - NOTES: STROBE LIGHT, READ DOME COLOR.RATED CLASS 1, DIV 2, GROUP D. 120VAC, 60 HZ. WITH BUILDING WALL MOUNTING BRACKETS. EDWARDS ADAPTABEACON MODEL 57AEXR-N5 OR APPROVED EQUAL. E-25 0 1 EA CONTROL EQUIPMENT -CONTROL PANEL -ELECTRIC 150-01 ITEM NUMBER - 30-999-0003 REQUEST NUMBER - 75 NOTES: EMERGENCY SHUTDOWN AND AUXILIARY RELAY PANELS AS PER 120.35.645 TO INCLUDE THE FOLLOWING POTTER BRUMFIELD RELAYS: #KHS-17D11-24VDC, 4 POLE RELAY #27E166, RELAY SOCKETS. ETC. * E-4000 A/R EA ELECTRICAL EQUIP -LIGHTNING ARRESTOR 238-01 ITEM NUMBER - 33-998-0002 REQUEST NUMBER NOTES: STAINLESS STEEL POINT- 5/8 INCH X 24 INCH WITH TAPERED TIP, THOMPSON SPECIAL ORDER ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: 522138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 72 OF 73 CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-4001 A/R EA ELECTRICAL EQUIP -LIGHTNING ARRESTOR 238-01 ITEM NUMBER - 33-998-0002 REQUEST NUMBER - NOTES: ADJUSTABLE POINT BASE- ALUMINUM, FOR HORIZONAL, VERTICAL OR PITCHED ROOF MOUNTING, 5/8 DIAMETER POINT THREADS, ROBBINS CAT. #A636 OR EQUAL * E-4002 A/R EA ELECTRICAL EQUIP -LIGHTNING ARRESTOR 238-01 ITEM NUMBER - 33-998-0002 REQUEST NUMBER - NOTES: AL/CU COMPRESSION SPLICE BARREL * E-4003 A/R EA ELECTRICAL EQUIP -LIGHTNING ARRESTOR 238-01 ITEM NUMBER - 33-998-0002 REQUEST NUMBER - NOTES: CAST RIDGE OR FLAT POINT BASE- ALUMINUM, 5/8 INCH POINT BASE THREADS WITH ANCHOR BOLT HOLES, ROBBINS CAT.# A46 OR EQUAL * E-4004 A/R EA ELECTRICAL EQUIP -LIGHTNING ARRESTOR 238-01 ITEM NUMBER - 33-998-0002 REQUEST NUMBER NOTES: CROSS RUN CABLE SPLICER- ALUMINUM, WITH FOUR 1/4 INCH BOLTS FOR TENSION ON CABLES FOR 9/16 INCH DIAMETER WIRE , ROBBINS CAT. # A635A OR EQUAL * E-4005 A/R EA ELECTRICAL EQUIP -LIGHTNING ARRESTOR 238-01 ITEM NUMBER - 33-998-0002 REQUEST NUMBER - NOTES: GROUND ROD- GALVANIZED, 1/2 INCH DIAMETER X 10 FT. * E-4006 A/R EA ELECTRICAL EQUIP -LIGHTNING ARRESTOR 238-01 ITEM NUMBER - 33-998-0002 REQUEST NUMBER - NOTES: CABLE FASTENER- LOOP TYPE, ALUMINUM FOR CABLES 3/8 INCH TO 5/8 INCH DIAMETER, ROBBINS CAT. # A72 OREQUAL * E-4007 A/R EA ELECTRICAL EQUIP -LIGHTNING ARRESTOR 238-01 ITEM NUMBER - 33-998-0002 REQUEST NUMBER - NOTES: TEE CABLE SPLICER- ALUMINUM WITH FOUR 1/4 INCH BOLTS FOR TENSION ON CABLE, ROBBINS CAT. 0664 ENGINEERING DESIGN FLORIDA GAS TRANSMISSION COMPANY RUN DATE: 12/03/93 PROJECT NUMBER: S22138 MATERIALS LIST RUN TIME: 16:41:32 PROJECT NAME: FGT - STATION #20 PAGE 73 OF 73 . CTR MARK REQUEST QUANTITY UNIT NO. PURCHASE ORDER QUANTITY QUANTITY NOT QUANTITY QUANTITY QUANTITY FUR NUMBER AND UNIT ITEM DESCRIPTION PRIME -SUB OR TRANSFER RECEIVED ACCOUNTED TRANSFERRED SURPLUS INSTALLED * E-4008 A/R EA ELECTRICAL EQUIP -LIGHTNING ARRESTOR 238-01 ITEM NUMBER - 33-998-0002 REQUEST NUMBER - NOTES: ALUMINUM POINT- 5/8 INCH X 24 INCH, SOLID ROD, DRAWN TO SHARP POINT, THREADED TO FIT BASES AND POLISHED BRIGHT FINISH, ROBBINS CAT. A21C * E-4009 A/R EA ELECTRICAL EQUIP -LIGHTNING ARRESTOR 238-01 ITEM NUMBER - 33-998-0002 REQUEST NUMBER - NOTES: ALUMINUM WIRE- 28 STRANDS OF 14 AWG BARE WIRE, 9/16 INCH DIAMETER, 115,000 CIRCULAR MILL CROSS 'SECTION ROBBINS CAT. # A2 OR EQUAL * E-4010 A/R FT. POWER CABLE-1 CONDUCTOR, #2/0 AWG, STANDARD STRANDED 238-01 COPPER, UNSHIELDED, THWN INSULATION, 600 VOLT, 75 DEG C ITEM NUMBER - REQUEST NUMBER NOTES: GREEN COMPANY NAME: FLORIDA GAS TRANSMISSION COMPANY DISTRICT NAME': FT. LAUDERDALE PIPELINE OR STATION ACCOUNT NUMBER: 1994 CONSTRUCTION DRAWN BY: KMS DATE: 03/31/93 AS BUILT BY: DATE: / 7/ MICROFILM NUMBER: BY: DATE: CHECKED DATE APPROVED DATE APPROVED DATE REVISION - DESCRIPTION BY DATE APPROVED BID CONSTRUCTION vJ5z r 10 R _ CAJ/ _NST -1 1\�� Jvv N DRAWING "�I'M NO. FILE r.. i 4u� 4, y TITS GMWK 02 2 GMWK-102-2 G5-102-109 D-5 43—M —pAkg1 Im 231564—EE3 2 564 EE1 465 "EE1 106 (REF FRI-LACED) STD. N , MMI MWI LE r R 'SL0kd>&0 oRJ'x k' Xpr+% lw aJ+re4�dAr+ YO E 4] I R r•• -: nM.,z� n e (q tl' ins k R"' I vrxY.�,�rei� TIC STARTING SCH SYS. GINEERING STANDARDS 3o as I ronsmisslon Lompany Houston, T exos PRASE III EXPANSION COMI RESSOR STATION NO. 20 ELEC;lRICAIJINSTRUMENT DRAWING INDEX I1-. PIFRCI-:, FLORIPA CAS PM HUE CIRO P YING NUMBER 120.35.601/1, .�� FUNDAMENTAL ITEMS GENERAL RESISTOR VARIABLE RESISTOR OR RHEOSTAT eCONDUIT/CABLE NUMBER AND SIZE GENERAL CAPACITOR ADJUSTABLE CAPACITOR TM MOTOR ("M" MAY BE REPLACED WITH HORSEPOWER RATING) /.� METER INSTRUMENT (REPLACE * FROM INDICATING METER RLIST) FUSE- (REPLACE * W/FUSE CURRENT INTERUPTING RATING GROUND HALFWAVE RECTIFIER FULLWAVE RECTIFIER d1111111— BATTERY O �X1 O THERMAL OVERLOAD OGROUND ROD OGROUND TEST WELL * * * DETAIL CALLOUT DWG. NUMBER DETAIL LOCATED GN DETAIL NUMBER LAMP (REPLACE * WITH A * COLOR: R=RED, G- GREEN, A=AMBER, B - BL-UE.) AUDIBLE SIGNAI RELAY OR OPI 16A1 1: ; 11 (REPLACE * WITH DEVICE NUMBER) LA b SURGE OR L'GIII - ARRESTER 0 FUSED CUTOUT 0 WELDING NIF- ® H HOA _ HAND -Of F-,, ; ` 4. S STARI SIc_'P S!AT'Q"J � s S1 ,, [ rrr, , �� DRAWOUT CARRIAGE MOUNTED FUSE 0 J 1 , - 0 MAGNETIC OVERLOAD STATIC OR SURGE CAPACITOR BUS CONTROL POWER TRANSFORMER WITH DRAWOUT CURRENT u LIMITING FUSE VP PRIMARY VOLTAGE KVA VS -- SECONDARY VOLTAGE S SV 5 SOLENOID VALVE TRANSFORMERS WINDINGS GENERAL TRANSFORMER vvv MAGNETIC CORE TRANSFORMER CURRENT TRANSFORMER (10) I I I" CURRENT TRANSFORMER (30) -- POTENTIAL TRANSFORMER CONNECTIONS 30, 3 WIRE, DELTA 30, 4 WIRE, DELTA, GROUNDED 30, OPEN DELTA 30, OPEN DELTA GROUNDED 30, 'NYE OR STAR, UNGROUNDI1) t--1_ 30, WYE OR STAR, GROUNDED CIRCUIT PRO-I-EC;TORS QUICK DISCONNECT FUSE SWITCH CIRCUIT BREAKER W/THERMAL/ u) MAGNETIC TRIP CIRCUIT BREAKER W/MAGNETIC TRIP �r _-� CIRCUIT BREAKER: DRAWOUT TYPE �v o 0 MAGNETIC STARTER -1- *. STARTER CONTACT * (INDICATES STARTER SIZE) �— THERMAL OVERLOAD COMBINATION MAGNETIC STARTER AND CIRCUIT BREAKER b` CIRCUIT BREAKER _T STARTER CONTACT * (INDICATES STARTER SIZE) - THERMAL OVERLOAD I COMBINATION MAGNETIC STARTER AND FUSED DISCONNECT b FUSED DISCONNECT i * t-- STARTER CONTACT * (INDICATES STARTER SIZE) THERMAL OVERLOAD 0 CONTACTS & SWITCHFS BASIC CONTACT ASSEMBLIES N.C. I-0 NORMALLY OPEN CONTACT N C. 014" NORMALLY CLOSED CONTACT OCKING SWITCHES p/ CIRCUIT CLOSING SWITCH (MAKE) 0— -a CIRCUIT OPENING SWITCH (BREAK) o< TRANSFER SWITCH, 2 PO0 i]ION -OFF TRANSFER SWITCH, .3 POSITION LIMIT _SWI Cl ir_s LS NO NORMALLY OPEN CONTACT, CIRCUIT CLOSING, QIsi� (MAKE), MOYF:NTARY OR SPRING RETURN NORMALLY CLOSED CONTACT, CIRCUIT OFE "JI` G, C O (MAKE:), MOP."ENTARY OR SPRING REIUi<N PUSHBUTTON SWITCHES DEVICE NUMBERS FOR SWITCHGEAR APPARATUS 1 MASTER ELEMENT 51 AC TIME OVERCURRENT RELAY 2 TIME -DELAY STARTING, OR CLOSING RELAY 52 AC CIRCUIT BREAKER NORMALLY OPEN CONTACT, CIRCUIT CLOSING, 3 CHECKING OR INTERLOCKING RELAY 53 EXCITER OR DC GENERATOR RELAY O O (MAKE), MOMENTARY OR SPRING RETURN 4 MASTER CONTACTOR + 54 FOR FUTURE APPLICATIONS 5 STOPPING DEVICE 55 POWER FACTOR RELAY NORMALLY CLOSED SWITCH CIRCUIT OPENING 6 STARTING CIRCUIT BREAKER 56 FIELD APPLICATION RELAY D . o (BREAK), MOMENTARY OR SPRING RETURN 7 ANODE CIRCUIT BREAKER 57 SHORT-CIRCUITING OR GROUNDING DEVICE 8 CONTROL POWER DISCONNECTING DEVICE 58 RECTIFICATION FAILURE RELAY 9 REVERSING DEVICE 59 OVERVOLTAGE RELAY TWO CIRCUIT, MOMENTARY OR SPRING RETURN 10 UNIT SEQUENCE SWITCH 60 VOLTAGE CURRENT BALANCE RELAY ONE CONTACT EACH N.O. & N.C. * 11 FOR FUTURE APPLICATIONS * 61 FOR FUTURE APPLICATIONS O O 12 OVER -SPEED DEVICE 62 TIME -DELAY STOPPING OR OPENING RELAY FLOW SWITCHES 13 SYNCHRONOUS SPEED DEVICE 63 PRESSURE SWITCH FS O 14 UNDER -SPEED DEVICE 64 GROUND PROTECTIVE RELAY NORMALLY OPEN 15 SPEED OR FREQUENCY, MATCHING DEVICE 65 GOVERNOR CLOSES ON INCREASED FLOW * 16 FOR FUTURE APPLICATIONS 66 NOTCHING OR JOGGING DEVICE 17 SHUNTING OR DISCHARGE SWITCH 67 AC DIRECTIONAL OVERCURRENT RELAY 18 ACCELERATING OR DECELERATING DEVICE 68 BLOCKING RELAY FS 19 STARTING -TO -RUNNING TRANSITION CONTACTOR 69 PERMISSIVE CONTROL DEVICE "� NORMALLY CLOSED 20 ELECTRICALLY OPERATED VALVE 70 RHEOSTAT IL' OPENS ON INCREASED FLOW 21 DISTANCE RELAY 71 LEVEL SWITCH 22 EQUALIZER CIRCUIT BREAKER 72 DC CIRCUIT BREAKER 23 TEMPERATURE CONTROL DEVICE 73 LOAD -RESISTOR CONTACTOR LIQUID LEVEL SWITCHES * 24 FOR FUTURE APPLICATIONS 74 ALARM RELAY 25 SYNCHRONIZING OR SYNCHRONISM -CHECK DEVICE 75 POSITION CHANGING MECHANISM LSO 26 APPARATUS THERMAL DEVICE 76 DC OVERCURRENT RELAY NORMALLY OPEN 27 UNDERVOLTAGE RELAY 77 PULSE TRANSMITTER CLOSES ON RISING LEVEL 28 FLAME DETECTOR 78 PHASE ANGLE MEASURING, OR OUT -OF --STEP PROT. RELAY 29 ISOLATING CONTACTOR 79 AC RECLOSING RELAY LS 30 ANNUNCIATOR RELAY 80 FLOW SWITCH 0-7 NORMALLY CLOSED 31 SEPARATE EXCITATION DEVICE 81 FREQUENCY RELAY OPENS ON RISING LEVEL 32 DIRECTIONAL POWER RELAY 82 DC RECLOSING RELAY 33 POSITION SWITCH 83 AUTOMATIC SELECTIVE CONTROL OR TRANSFER RELAY 34 MASTER SEQUENCE DEVICE 84 OPERATING MECHANISM 35 BRUSH -OPERATING, OR SLIP RING -SHORT-CIRCUITING DEVICE 85 CARRIER OR PILOT -WIRE RECEIVER RELAY _P___R_ES_URESWITCHES 36 POLARITY OR POLARIZING VOLTAGE DEVICE 86 LOCKING -OUT RELAY PS O 37 UNDERCURRENT OR UNDERPOWER DEVICE 87 DIFFERENTIAL PROTECTIVE RELAY NORMALLY OPEN 38 BEARING PROTECTIVE DEVICE 88 AUXILIARY MOTOR OR MOTOR GENERATOR CLOSES ON RISING PRESSURE 39 MECHANICAL CONDITION MONITOR 89 LINE SWITCH 40 FIELD RELAY 90 REGULATING DEVICE PS 41 FIELD CIRCUIT BREAKER 91 VOLTAGE DIRECTIONAL RELAY 0 v NORMALLY CLOSED 42 RUNNING CIRCUIT BREAKER 92 VOLTAGE AND POWER DIRECTIONAL RELAY !l OPENS ON RISING PRESSURE 43 MANUAL TRANSFER OR SELECTOR DEVICE 93 FIELD CHANGING CONTACTOR 44 UNIT SEQUENCE STARTING RELAY 94 TRIPPING OR TRIP --FREE RELAY T- IVIPERATURE SWITCHES 45 ATMOSPHERIC CONDITION MONITOR 95 ONLY FOR SPECIFIC APPLICATIONS NOT COVERED BY 1-94 -- 46 REVERSE -PHASE, OR PHASE -BALANCE, CURRENT RELAY 96 ONLY FOR SPECIFIC APPLICATIONS NOT COVERED BY 1-94 TS O 47 PHASE -SEQUENCE VOLTAGE RELAY 97 ONLY FOR SPECIFIC APPLICATIONS NOT COVERED BY 1-94 NORMALLY OPEN 48 INCOMPLETE SEQUENCE RELAY 98 ONLY FOR SPECIFIC APPLICATIONS NOT COVERED BY 1-94 CLOSES ON RISING TEMPERATURE 49 MACHINE, OR TRANSFORMER, THERMAL RELAY 99 ONLY FOR SPECIFIC APPLICATIONS NOT COVERED BY 1-94 50 INSTANTANEOUS OVERCURRENT, OR RATE -OF -RISE RELAY OTS NORMALLY CLOSED * NUMBERS RESERVED FOR FUTURE APPLICATIONS. --� I OPENS ON RISING TEMPERATURE TIME 0[- I AY SWITCHES Tu o NORMALLY OPEN SWITCH WITH TIME DEIAY CLOSING UPON ENERGIZING COIL NORVALLY CLOSED SWITCH WITH TIME DELAY OPENING UPON ENERGIZING COIL NORMALLY OPEN SWITCH WITH TIME DELAY CLOSING UPON DE -ENERGIZING COIL ID NORMALLY CLOSED SWITCH WITH TIME DELAY �� OPENING UPON DE -ENERGIZING COIL NDICATING ME==TER LIST AM AF.1METER AN AP' 'ERE -HOUR METER DM )1,VA.ND MEIER F.T Fl Al' SFD TIME MF_IER FM IREQUENCY METER GD GROUND DEEU1OR M NDICAIIING MF I 2 OHM OHMEILR [IF POWER FACIOR METER PH PHASE METER PI POSITION INDICATOR RD RECORDING DEMAND MILLER REC RECORDING MEIER SY SYNCHROSCOPE TI M TELEMETER I r IOIAL 1IME METER UA NICROAYMI-IER VM VOLI VETF R VA VOLT -AM MEIER VA RH VARHOUR MFTER WM WAT1YI:1ER WH WAITHOUR METER N ii13 11/1/9.5 1)OK 9/0.5/93 i, BY DALE CHK'D,APP'D SUFFIX LETTERS AUXILIARY DEVICES MAIN DEVICES SEPARATE AUXILIARY DEVICES C - CLOSING RELAY OR CONTACTOR CL - AUXILIARY RELAY, CLOSED (ENERGIZED WHEN MAIN DEVICE IS IN CLOSED POSITION) CS - CONTROL SWITCH D - "DOWN" POSITION -SWITCH RELAY L - LOWERING RELAY 0 - OPENING RELAY OR CONTACTOR OP - AUXILIARY RELAY, OPEN (ENERGIZED WHEN MAIN DEVICE IS IN OPEN POSITION) PB - PUSHBUTTON R - RAISING RELAY U - "UP" POSITION -SWITCH RELAY X - USER CHOICE Y - AUXILIARY RELAY Z - POSITION ACTUATING QUANTITIES _ — A - AIR, OR AMPERES OR ALTERNATING C CURRENT D - DIRECT OR DISCHARGE E - ELECTROLYTE F - FREQUENCY, OR FLOW OR FAULT H - EXPLOSIVE J - DIFFERENTIAL L - LEVEL, OR LIQUID P - POWER, OR PRESSURE PF - POWER FACTOR Q - OIL S - SPEED OR SUCTION OR SMOKE T - TEMPERATURE V - VOLTAGE, VOLTS, OR VACUUM VAR - REACTIVE POWER VIT - VIBRATION W - WATER, OR WATTS OW(`,, �CN CCK ED APPROVED WORK ORDER NUMBER STATUS BY DATE BY DATE DY DATE S?!-138 P.L. OR STA. ACCOUNT NUMBER I ; - 1994 CONSTRUCTION BY ll DATE - — DESIGN _ 1 DM 1/23/9 DRAWN 41 AS - 111 /23/9 1 AS BUILT I MICRFLM - MICRFLM _ -- - f ILE NO, SCALE NONE M __ r- A - ALARM OR AUXILIARY POWER AN - ANODE AC - ALTERNATING CURRENT B - BATTERY, OR BLOWER, OR BUS BK - BRAKE BL - BLOCK (VALVE) BP- BYPASS BT - BUS TIE C - CAPACITOR CA - CATHODE CH - CHECK (VALVE) D - DISCHARGE (VALVE) DC - DIRECT CURRENT E - EXCII ER F - FEEDER, OR FIELD, OR FILAMENT, OR FILTER, OR FAN *G - GENERATOR, OR GROUND H - HEATER, OR HOUSING L - LINE OR LOGIC M - MOTOR, OR METERING *N - NETWORK, OR NEUTRAL P - PUMP OR PHASE COMPARISON R - REACTOR, OR RECTIFIER S - SYNCHRONIZING OR SECONDARY OR SUMP OR SUCTION (VALVE) T - TRANSFORMER, OR THYRATRON 1H - TRANSFORMER (HIGH VOLT isl-- 2 TL - TRANSFORMER (LOW VO SIDE) 3RS TM - TELEMETER f s� U - UNIT H D f�,'' N In � *NOTE ��� I' SUFFIX "N" IS GENERALLY USED IN PR l l_NCE T G" ,66i DNICES CONNECIED IN THE SECONDARY NEUTRAL OF CURREN T OR IN THE SECONDARY OF A CURRENT TRANSFORMER WHOSE PRIMA IS LOCATED IN THE NEUTRAL OF A MACHINE OR POWER TRANSFORMER, EXCEPT IN THE CASE OF TRANSMISSION LINE RELAYING, WHERE THE SUFFIX "G" IS MORE COMMONLY W,t D FOR THOSE RELAYS THAT OPERATE ON GROUND FAULTS. FKf 7,� l ti-VF-R`oA1_ - nsco ac. Florida Gas Transmission Company Houston Texas _ PHASE III EXPANSION GAS PIPE" ` ` ,i COMPRESSOR STATION NO. 20 ELECTRICAL SYMBOLS AND LEGEND FT. PIERCE, FLORIDA DRaw ,c NUMBER STING SERVICE LOCAL POWER COMPANY FM VM l W l AM FUSED C AT TRAN`. POLE U U TRANSFORMER 480, 3 PHASE, UTILITY CO. PHASE III 4 WIRE STATION S CONTRACTOR NOTE: CONTRACTOR TO INSTALL METERING EQUIPMENT IN 1P ACCORDANCE WITH UTILITY COMPANY SPECIFICATIONS. 1A 1B 4" 4" METERING CT'S POWER COMPANY REVENUE METERING b 8011AI= 3P 800AT a /} SERVICE DIS�O PHASE II EXPANSION EXIST. SWITCHRACK #II-1 SEE-DWG.-120.35_504C NOTES: 120V 480V i 800 AMP A PHASE) 800 AMP 1091I VS AS TRANSFER SWITCH' 47 WH V1 DM 3P 800AF (2) 1/0 600.AT SOLID NEUTRAL (6) 500MCM H CONDUIT EXISTING PLJ" 1 CONDUIT b CABLE IN 01'4 •• • 1� Iw• • INTO NEW C sYY AA CONDUIT a a= • i • ! I 2 PHASE III CO3 DISCONNECT2. •• RECEPTACLE (CONDUIT '`A , •��� r� pt� ANF � III • I�• • - REMOVE,f v'�i n -ALLED TO SHOWN WHEN THE NEW Y + :, kF i • • IN - .m "y z r, L 5 3. • • ti£RVP•" d �; �b x • NNECT THE • ASSOCIATED JIN THE BUILDING ONLY• • AND IS III Y 4. g EXISTING I• d: V EQUIP GROUI ACK #1 35.1C 3)CT 600 (2)PT 480/1 4 GENERATOR CONTROL 3A 3B S 3" i METERS & AUTOMATIC ANNUNCIATORS ENGINE START/STOP 600A CONTROL_ --- L GAS START TOR -"�I�� CONTROL TOR ,, I 1JG CONDUITS" w G CONDUIT . NDONED ` CONDUIT TO SE III EXPANSION CATES PULL BOX STATION 3P sT 400AF 3P a sr 400AF 3P i 225AT 225AT l 1 1 120V 120V ESD ESD (SEE DWG. (SEE DWG. 120.35.645) 120.35.645) I �2 #12 2 #12 I COIL AND TAPE _'Ya 2 #12 SPARES SOLID NEUTRAL GROUND BUS 11 i0--- WX PHASE FUTUF EXISTING MCC #1 SEE DWG. 12.0_35.6C 48OV, 30, 60HZ., 500 AMP BUS YC, 3-250MCM 1 #1/0 (NOTE #1) L — __ EXISTING PULL BOX T (2- .,jOTE #2 ^ 1 225AT I 150AT (NOTE #1) 2"C, 3 #1/0 —c� (EXIST.) � JI �TEMPORARY) 9 NOTE #2) 2„ 73 2" 72 1 �/2 71 1" 70 1" V 1 V\ V I V\ V V 3P 1 75A 150AT 15AT I 15AT 15AT 25AT / / / O O O 0 0 2 R FR..E 2 S S NOTE: PHASE III CONTRACTOR S INTERLOCK EXISTING AIR COMPRESSOR STARTER WITH NEW AUTOMATIC TRANSFE R SWITCH (ATS). WHEN ATS IS IN EMERGE POWER POSITION, EXISTIN�P IS TO BE ,LOCKED OUT. 200A, 48OV, 30 FUSED DISCONNECT SWITCH 200A, 48OV, 30 PORTABLE GENERATOR RECEPTACLE PBS2 PBS3 PBS4 PBS5 PBS6 PBS8 PBS9 c 25 WITCH RACK #4 SEE DWG. 120.35.604 EXISTING AIR (PHASE 3 EXPANSION) COMP. #1 TO BE REMOVED BY CONTRACTOR__ AF iER NEW MCC #2 IS INSTALLED AND OPERATIONAL SEE DWG. 120.35.640 '• ....:._,.....,....._.,�...,..,...__d........_..��...«............... «,....-... �T DWG. STATUS woPK ORDVE3E R ER NUMBE DER S22138 .....-......-. CHECKED BY I DATE »APPROVED - - BY DAIE BY DATE Florida Gas Transmission Company PE. OR STA. ACCOUNT NUMBER HOUSt O_ n' Texas - PREL'Y ] 1994 CONSTRUCPON 1 PHASE III EXPANSION - - - >. + - - — DeslcN BY DM � DAfE - 1119/93 COMPRESSOR STATION NO. 20 4.� 131D -t - — DRAWN AS 1jisf93 ONE LINE POWER DIAGRAM — — 1 cur D FOR CONSTRUCTION 7 / _� I DCM 11 1 LaS CGNS11R. I { •;/ As BUILT - — -- ELECTRICAL u UED I OR BID KJH T 0.3 "J3 / / 1 , PLOT DAIE: OS/24/93 MICRFLM _M��RFLM- File NO. — FT. PIERCE, FLORIDA IJO. t�EVISICN - DFS(;RIP110N BY DAIE CHK'D,APP'D CADDS - - DWG \,2 Li ZtLFE35603 1 SCALE NONE 1 i--_7 191, B 9 Onx Sul' b0 UNIVF 2 AI_. P.O. Bo, 57P<B ro NC H .tun Te m 17157LLB (713) 977-7710 C ,WING NUMBCR _. _ 120.35.603/,;`� CONT. FROM DWG. 120.35.603 6 3" 400A, 480V, 34 NF DISCONNECT SWITCH 3P 200AF 3P \ 100AF I 125AT / J 30AT II 2 SOFT START CONTROLLER 3" C. 3- 250 MCM XHHW \ R R R R G G it � II II II II UNIT _ CONTROL - PANEL 11 1" PROVIDED BY AIR COMPRESSOR 10 21 12 VENDOR COORDINATE W/RACK HP AIR CI L pMPRESSOR C-2030 lglOA L T CR/ s / \ J.W. HEATER 15KW H-565 - "RUNNING" PILOT 11 - "STOPPED" PILO, C / \O - "AUTO" PILOT /\ - s - PUSHBUTTON ST n - HAND/AUTO H o - HAND/OFF/ 0 — OFF/AUTO u T - TEMP - PHOTO ELECTRIC CELL PERMISSIVE INTERLOCK B 2 HP / R s J.W. HEATER \ G LUBE OIL HEATEF CIRC. PUMP 26KW . P-565 H-202' - 6 7.5 � 1 HP / R HP PRF_/POST <G COMPRESSORLU E OIL / BLDG 2 OIL PUMP SUMP P MP P-2020..: , P-701 120.351603 BONE LINE POWER DIAGRAM 120.35.605 ELEMENTARY DIAGRAM 120.35.607 1 IKEY ELE/INSTR. PLOT PLAN 120.35.614 ,AUXILIARY BLDG. AREA PLAN I I � I \.1/ I GAS DETECTION SYSTEM 12 5 �16 PSH i14A HP /(G) HP / R \ \�/COMP. UI COMP. BLDG.#2 COMPRESSOR BLDG.#2 VENT FAN BLDG #2 / \ VENT FAN PURGE VF-201 VENT FAN VF-203 VF-202 Ai . li, x, ter ea" {acar u n r t 3P \ 100AF J AnAT f I 2- 2 26A 11 %z . COMPR. BLDG. #2 A s LIGHTING j PANEL /W A OOA. MAIN \ BREAKER C 3P�1 100AF / 30AT I Q FLOOD LIGHTS LIGHTING ` PANEL WELDINGAR 480 V, - - _ - - I STATUS - VED BY li` CDATOE_ BY DATE E BY DATE 1 - - WORK ORDER; R S221U38 P.L. OR - A. ACCOUNT NUMBER 1994 CONSTRU CT ONBY --DATE Florida Gas Transmission Corr Houston Texas PHASE III EXPANSION - - - 1 DESIGN— DM o1os/93 COMPRESSOR STATION N0. 20 P31D _ -- - - DRAWN -- JEB 01/06/93 ONE LINE POWER DIAGRAM 1 ISSUED FOR CONSTRUCTION 1T8 t/t/93 roNSTR. _ - # -- �hE_ ,h j AS BUILT ELECTRICAL 0 {ISSUED FOR BID DDK_ th 19/03/93 PLOT DATE: MICRFLM FILERNo__ FT. PIERCE, FLORIDA NO. REVISION DESCRIPTION BY DATE CHK'D APP'D CADDS DWG. S22138 E 2.035604 SCALE NONE UN Vi 2 nL 0 Box S .. nC2<e 977 77,0 a.. Im Pant ru NO Fa 1-1 Av�il�ii A it \aF±vp;RIF�1 DRAWING NUMPER 120.35.604�1\ L 1 c i 0- 480VAC 30,60HZ. L2� o- I CF L3 CF CF ujijW CPT I 1 1 480/120 H I Li GATE CONTROL CTS LOGIC Al RUN RESET MODULE 1' ON OFF / (�.�C R Y-'1-0-9 RESET (SEE NOTE #1) LEGEND ❑ TERMINAL BLOCK IN STARTER UNIT O TERMINAL IN AIR COMPRESSOR CONTROL PANEL. 480VAC, 30, 60Hz L1 L2 L3 I I _1_I 11J M CPT CF 480/120 FC 0. L.'S ELEMENTARY WIRING DIAGRAM AIR COMPRESSOR #3 C-2030 60HP CTN PTS N R G NOTE: 1. THE CR CONTACT IS LOCATED IN THE DONTROL PANEL FURNISHEE BY AIR COMPRESSOR VENDOR. LEGEND ❑ TERMINAL BLOCK IN STARTER UNIT ESD--2 PANEL Q TERMINAL BLOCK IN CONTROL J-BOX 48OVAC, 30, 60Hz L1 L2 L3 T M LEGENDS: O TERMINAL BLOCK IN JACKET WATER PUMP & HEATER CONTROL MODULE IN STARTER UNIT m CONNECTION IN UNIT CONTROL PANEL O CONNECTION IN HEATER J-BOX O TERMINAL BLOCK IN CONTROL J-BOX :PT )/120 r35� SEC TD SEQUENTIAL RESTART 1 TIME DELAY RELAY ^F (SEE NOTE #2) TD1 JACKET WATER CIRCULATION PUMP (P-565) 480VAC, 30, 60Hz L1 L2 L3 bqn� Qdn� bQ^� HS-565A------- B PUMP AUTO 0 F LOCATED IN / <? 9 I 1-565-1 COMPRESSOR BUILDING -Q--♦-�--0{ F(>----- OVERLOADS CB-3 CB-4 M - LOCATED IN M1 COMPRESSOR BUILDING M2 C2 PUS Mf - R PUMP RUNT G STOP i INTEGRAL HEATER B HS-565B BEATER AUTO P r� F THERMOSTAT / \ TS-565 M3 o LOCATED IN C1 \ / COMPRESSOR BUILDING HEATER ON /R\ _ C CB-53 CB-54 565 (603JW) CR-427 + 24V 0--" F1 F2 P5 24V RTN SEQUENTIAL RESTART — JACKET HEATER TER ID TIME DELAY RELAY (SEE NOTE #2) FAN UTO\ / 15 KW ELEMENTARY WIRING DIAGRAM 24 VDC 1 I — — — — — — — — — — B--471-1 JACKET WATER PUMP & HEATER LOCATED IN -�� (H-565) INTERPOSING COMPRESSOR / \ I (P-565) & (H-565) RELAY ICB-11(VF-202) CB- 1 2(VF-202) BUILDING, CONTROL J-BOX CB-13(VF-203) GDI-1 CB-14(VF-203) I ON SWITCKRACK #4 TD-1 9I T — _�i L1 L2 L3 �% 5 AMBIENT p THERMOSTAT CB_ 17, CB--18, C g = Q19� GDI-2 Q20 OVERLOADS - M LOCAL TO J L r J (COMPRESSOR BUILDING — INTERMITTENT VENT FANS VF-202 &_VF-263 M1 / ^ R �r FAN RUN�� \ M2 / FAN STOP / \ 2-1-131-19 2EFS 2-TB1-20 CB-59 CB--60 24131-12 A-24DC --p_i �_0— _ -0- GDI _ � -_o-24VDC RTN 2 -TB1 -27 28GESDX 2-TB1 -28 CB-61 (SEE NOTE 3)I -q- `�— i-O_—�_ "-�- GDI (SEE NOTE 3) B-9 GDI-1 - CB-10 LOCATED IN ^� j CB-15 CODMP2ESCSBR16LDG/ \OVERLOADS( - PSH-514A ^ ELEMENTARY WIRING DIAGRAM [J -O-i { 0- J(}-04--�L M-r TYP. FOR (1) CONTINUOUS VENT/PURGE (AN VF-201JI & 2 INTERMITTENT VENT FANS VF -202, VF -203 COMPRESSOR BUILDING CONINUOUS VENT PURGE FAN ONLY VFF-201 c> �__--_� -�v NOTES_ s 1. ALL CONTACTS SHOWN ON THIS SHEET ARE IN -SHELF POSITION. 2. ALL TIMING RELAYS SHALL HAVE MINIMUM ADJUSTABLE RANGE 50% MORE THAN THE MINIMUM SET TIME NEEDED. 3. ALL GAS DETECTOR INTERLOCK (GDI) Rf LAYS FROM ALL THREE VENT FAN STARTERS ARE CONNECTED IN PARALLEL AND CONTROLLED BY o SINGLE GAS DETECTOR ALARM AND SIIUIDOWN CONTACT OUTPUTS. T I� 120. 5.603 ONE LINE POWER DIAGRAM 120. 5.604 ONE LINE POWER DIAGRAM a 0. L.'S IN gig C fPUMP AUTC �• -roxi• LOCATED I •r,,,1-1"1,",M—l""OOCOMPRESSOR BUILDING ♦ ♦ • • OVERLOADS LOCATEDCB-5 CB-6 COMPRESSOR • • • ♦ Q PUMP M2 C2 G STOP i C ^i f HEATER ON R - - - DWG. STATUS criturctu BY DATE -- _ Hrrr<uvtu DATE BY DATE ���m^�^ S22138 Florida Gas Transmission Company Houston, Texas PL OR STA. ACCOUNT NUMBER PHASE iPl EXPANSION COMPRESSOR STATION NO. 20 ELECTRICAL --- --- --- _- __. PREL'Y BID --- --- - --. - -_. _ _. - - _. _. 1994 CONSTRUCTION -- BATE - DESIGN DM 08/07/93 _DRAWN- - KJH 08/07193 -_- RLS --- DDK 19/03/93 - -- BY 11/1/9 -- DATE _ CHK'D __ - APP'D CONSTR. CADDS { PLOT DWG. DATE: S22138 '=� AS BUILT - MICRFLM —MICRFlM FILE NO. - SCAM NONE ELEMENTARY DIAGRAMS FT. PIERCE, FLORIDA - __._ 2035605 - - - -- R DRAWING NUMBER 120.35.605 ii '. XIM 0 o HWY 68 0 0 0 - ----------- AV 0 ( ORANGE + + + 00 La Lj ft -a BLOWDOWN SILENCER /0^ 1 10 EXIST. 18"0 SUCTION I-XISF. 18"0 DISCHARGE II EXIST. 260 SUCTION j EXIST. 26"0 DISCHARGE III pp S 10+70'—:t Ld -77 FIRE HYDRANT 0 #2 F-F7 OFFICESI I PIPELINE AUX... - C - BIL TOWER 0 F.H. #5 o 0 0 DITC POND 0 CD 0 + 0+ 0) LLJ 0 0 RESIDENCES LnJ 15' RADIU S 1+00 PIERCED WAL S 2+00 S 3+00 RIF"4 1 Z'z!"- PAINT STORAGE P] : I r ROOF LIMIIS COMPRESSOR BUILDING DIERCED WALL JRCE DE 15' RADIUS VARIES DEVICE m NON CLASSIFIED E3 DIVISION 1 rM DIVISION 2ash-69 1. HAZARDOUS AREAS OUTSIDE OF BUILDINGS EXTEND TO 15'-0P ABOVE THE HIGHEST POINT OF THE EQUIPMENT LOCATED WITHIN THE HAZARDOUS AREA. 2. HAZARDOUS AREAS INSIDE BUILDINGS EXTEND TO THE ROOF. 3. A 15' RADIUS CLASS I DIV. 11 AREA EXISTS AROUND THE VENTING POINTS OF ALL PSV.'S, GOV.'S, GAS POWERED PUMPS, ETC., NOT CONNECTED TO A COMMON VENT HEADER. 4. CLASS I i DIV. 11 AREAS OUTSIDE OF COMPRESSOR BUILDING EXTEND TO S 8+00 15'-0" ABOVE THE HIGHEST POINT & 15'-0" FROM A PIERCED WALL WHERE ADEQUATE VENTILATION EXISTS. DWG. CHECKED APPROVED WORK ORDER NUMGLR I T - r I I BY DATE BY DAIS DAI -E BY DATE S221 J8 --STATUS- Florida Gas Transmission Company PRrL'Y P.I. OR STA- ACCOUNT NUMBER 1994 CONSTRUCTION - - - Houston, Texas r PHASE III EXPANSION By DATE DESIGN DM3/1 2/U COMPRESSOR STATION NO. 20 BID DRAWN AS 3/1193 AREA CLASSIFICATION PLAN 1 ISSUED FOR CONSTRUCTION TTI3 ill/l/9- CONSI-R. -3 AS BUILT 0 - ISSUED FOR BID (38 9/03/9' - - — - - - -- PLOT DATE: 3/_12/93_ MICRFUVI ---MVtf-LM-- FT. PIERCE, FLORIDA NO. REVISION - DESCRIPTION 13 LY CHK'D�APP'Dj CADDS DWG. FGE-1684D-5101 -n-LENO.- SCALE 1 50'DATE - / 1Bt! BrRNG Okry - UNIVERSAL P.O. BOX 57D248 INC. HOU�ION.7EM 77257-0248 (713) S77 7770 ENEW41W GAS PIPELEN.NY.- GROUP DRAWING NUMBER 120.35.606 I f F1 n I , X0. O LO DRAWING LIMITS S 8+70'-2" ,. w � r----- -----� IIr — — — — — I II I III I I II I III I I I I II I I II I III I I II I III I' I II I III I L, I S 8+84'-2" II - - ------ tri-- - - -� I I it I I I it I I I II I I I II I II II I II U 26" SUCTION LINE S 8+74'-2" B.O.P. EL. 23'-5 LCV 2003 r'---i —I 0-------, I ! Pdl 8 120.35.641 2003 I I II LC II f— I I FOR CONTINUATION SEE DWG. 120.35.615 303 2" SPARE 302 300A 124PR 16 SH 300E 11PR # 16 SH I I 2003 [307A 1 307 P-R -16 SH --SEB- DWG. V-20013 12120.35.E5 2003 LsHH J �i . .. ._ - - - - I 2003A I TIE INTO EXISTING PNEUMATIC TRIP CIRCUIT SEE P & ID 120.60.607C 18 —.500 X52(G-1220)1 B.O.P. EL. 33'-4"t S 9+00'--0' 2 a (jas ira Ion company [IOU9t PHASE III EXPANSION COMPRESSOR STATION NO.20 I'LECTRICAL/INSTRUMENTATION GAS SCRUBBER AREA FT. PIERCE, FLORIDA e 1 E LINE `I 306 1 _ ]_ � 1811 penny pri.e - Suite 400 SAL_ ?0. Be. 57024E vc. HD�91on,TUuf n29-02a8 T-.;..7 (7U) 97I-7710 Nm '"""AS PIPELINE GROUP DRAWING NUMBER 120.35.608 //� P I EDGE OF COMPRESSOR BLDG. MATCH LINE S.7+98'-9 112" FOR CONT. SEE DWG. 120.35.613 - - --- ------ --- -- SOUTH E LDG. WALL I I I I I II I II I I r' CI P-701 I I I I I I I I II �) I I / TO EMERG. LTG. —_--- ----- -�--_ - SUMP PUMP ! SEE DWG. 120.35.616 �I I III I I lllli �� I I FOR /�I I�(I}II'I�III � n ►IIII II(I F-2_080CAONTINUATION 23 0+S CN 1P COMP. BLDG. WEST WALL 70 (REF) CD LSH/L —_ -❑®- -==---a=_ ,B SILENCEP, -�,- �_!> I � HS �,l �/ �/�/ IIIIII I I- _ � �y. I I I I 00 + �_ THWN3 #12� �1 r 1 I 16 23 15 13 GRND + �ii // 1Yz 29 1„ 17 1„ 14 1„ 12 1„ "TI/�� ///// / b /SESD TA 7 -- 1„ w /+14'-9 2" T - 11 • 6 20 I 22 25 11 6 a- 6 I PSV 3" 1" 1" 1" 1" • SWITCHRACK #4 _ C-2030 S-2083 . • • • • • •. 2070 V-2070 20 0 19 21 24 28 907 AIF' (EXHAUST COMPRESSOR SILENCER !- '- H I I I f 907 16 i_� PSH L \ / 1 I I I 2030 I I I I I I u\ HOA II I S ---------------------- ------ -- 2030--------- - ----I-- ------- I j------------- ' - - - - - - - - - - - - - - - - - - - - - - -- --- --- ---- -- ---------------------------------- - I I I I I I I I i S 8+29'-0"- I I I I I I I i I I I I I 105 6 907 17 I I I 1TV TY L 8 120.35.641 7 120.35.641 5 6B 5668 1'/z 1., � I Pdl _ I I I I I i 7 120.35.641 `i69B 56 B 2072 I I I I - - I ; I I I I I i I ��-�Z• - - - n i n I __ n It C�1 —_� TO EMERG. LTG. SEE DWG. 120.35.616 FOR CONTINUATION I H I i 1"C, 3 #12 I 3' WALK E8+12'-3 1 2' 1 I i I H I i ESD STA #8 ----------------------'- 0 CN ---------- -- + ---------------..---------- Ln I_- 1� IJ C� Z Q r� 1 1 Pdl g 120.35.641 2071 1 I I I of +I EXISTING EXISTING SIDEWALK ' 56HB I I 56HA ` 560 w SIDEWALK I I HE-561 v E-560I I I I I II I I I I I I I 1 I 1 i---1----i---1------ ---------------- -------------------------------------- --- ----- - - _ -- - - _- _-_ -_ - - - - - __ __ ____________________ ______ __ ___ - ----- _____ - _ __ _ _-_ ___ _ ____ I------------�---------- -----------------Ir�r---------------------------------------------------------------------------------------------------------------------------------- -------1-------L---J------- ---- -------------`------------------------------------------------- ---- ---- ----------------- ---------------------------------------------------------------_____________________________________________________________________ ---- 1 I I I ri 3 WALK E8+60'_0' I I 300 301 302 303 I I I 2" 2„ 2„ 2„ I LO:, I I I I I I I I 1 I I I I I 17 6 907 40 z D 1 I I I I I 3" 1 1V 1„ oUi I I I :D N ----l---�--— — — — — — — — — — — — — ------------------------------------------------------ — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — ----------------------------zmz PBS c� - - - - - - - - - - - - - - - - -- - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -� - 1811 BERING DRIK - SUITE .00 I I I I I >I I I I I UN NERSAL P.D. BOX 570248 ENsca, wc. 40uSi0NJUUS 77257-0248 r WORK ORDER NUMBER --------- 1 I I — - _ - DWG. CHECKED APPROVED _ ---- I I�t STATUS BY DATE BY DATE BY DATE S22138 Florida Gas Transmission Company � ' I — —— -- - P.L OR STA ACCOUNL NUMBER Houston, Texas k k PHASE I TO( IJB I - - _ - -- _ - PREL'Y - D9 �N coNCMH 07 2893 C1�MFRESSOR I STATION EXPANSION 2��s r P �N " i BY DATE c7` FOR CONTINUATION BID DRAWN KJH 07 28 93 ELECTRICAL u4ky'L�j_ SEE DWG. 120.35.608 -- _ -.__ _-_ _ - 1 ISSUED FOR CONSTRUCTION AS 11/1/93 As BUILT -� -_ CONSTR. - - COOLER FAN AREA - -- - - -- 0 ISSUED FOR BID DDK 9/03/93 - --- - uicRFiM ---- FT. PIERCE, FLORIDA - - - - - -- --- - PLOT DATE: _ __ N0. REVISION - DESCRIPTION BY DATE CHK'D APP'D CADDS DWG. S22138 2035609 scALE 1 4 1'-0 j T, rr — — ....... 1L ______� tY __ T_L——_-�_--_T-__-- 1 �In DRAWING LIMITS S 7+24'-0" I I l,� 1111 1 FLOW COMPUTER I I I I II I-+II� (EXISTING) I I I III I' I of I I I I III III I I EXISTING CONDUIT �I j I I I i rili iji i i�i I wl j I I I i 1 ili iji I III I J I I'I I , I I I I IIII 111 I II� 121 n 1 I I I I LII-IIII CDi I I I i TIT IIH , 121A E 11 -- 11 TT RR 11 1166 SS H 121C 1-1TR1 #16 SHH W J� - �J rtYIIIIIII1'III'l1I,t�IIIIIII1 -- yIYIIIIIII'IIIIl,I1II1IIrI , ^v0�I'II',lI ----th1IIIIIII1I1I,II'II11IIIIIII1 � iP i T r\f : : : : IIIiI =- _--- -- O >-- �' un N No0 C° EXIST. - -6"-- --EN Ld G. -FUEL REMOVE EXIST. METER -----------------------------------------III- -II RUN & INSTALL NEW „-SPOOL AS SHOWN-L----------------------- -�— -- --- _ - - } � � 11 EXIST. 2" DO M. FUELCD I roNOTE I1ABOVEGRADE=__ TULL POINTIIP O 4"-.237 B FG-1 2056D 2 2" EXIST. PDM --------------- - - - - - O L'jiN IS. ED KIVW rr)KIn W J� - �J rtYIIIIIII1'III'l1I,t�IIIIIII1 -- yIYIIIIIII'IIIIl,I1II1IIrI , ^v0�I'II',lI ----th1IIIIIII1I1I,II'II11IIIIIII1 � iP i T r\f : : : : IIIiI =- _--- -- O >-- �' un N No0 C° EXIST. - -6"-- --EN Ld G. -FUEL REMOVE EXIST. METER -----------------------------------------III- -II RUN & INSTALL NEW „-SPOOL AS SHOWN-L----------------------- -�— -- --- _ - - } � � 11 EXIST. 2" DO M. FUELCD I roNOTE I1ABOVEGRADE=__ TULL POINTIIP O 4"-.237 B FG-1 2056D 2 2" EXIST. PDM --------------- - - - - - O L'jiN IS. ED KIVW rr)KIn (EXIST.) RV W 102 w I z I J I 1 119SI RATOR DISCH. N __—_—_—_—_ b — 7+610SEOPT x I 112299A811PPRR 1166 SSHH — — — — — — — — — — — — — — — — — — — — — — — — — — S'-_216 B FG-1 2056B w - ---Z------ z------- - FOR CONTINUATION SEE DWG. 120.35.615 I 1__216 BAG=1)2056A Ill - I 205 2052 I I I ----III--------------- - - - - - - -- - ----------- — — — — — — — — — — — — 1 1 0 I 0 + 1 (.6 1 W (n J 1" SERVICE AIR ' TO BE DISMANTLED & ROUTED AROUND "NEW' z1 RELOCATE EXIST. METER RV FILTER/SEPARATOR LOCATION ri I -1 (EXIST.) I I I - 103 EXIST.) PI I RUN HERE. A ! o 1 I I I PC TW 205) 2052 -- i--' -- - I I Li 102A 2052 I � �>r�ra a�'�'a ��a� a`�`�`�`�`��c�.- ' � I'1 T T T ICI m -- 4, -- - 4„ -- ---- - --- ---�- 1„ p�QT AIR I'I ' II' 1'I -- -- --------------------- 1 n,rti m I -I 4 1 L ------------------ III►��II� i _- ® �No U:=r='— r - � = J - _ , I III __— = = = 3- - - - - -- --- II1I 4"-.237 B(FG-1)2050 2 PSV EXIST., TYP. ?049 2" SUCT. GAUGE 2" 1" DISCH. GAUGE 2" ENG. FUEL GAS __ __---==-____-_- 11 ---- ----------- � ( _ _ _ _ 'i l I l iill ii i j ii i ii ii!lii iI -- ------ -------- _ � ____ U-------------------------------- _------_------_------_------_-----------------------------------------------------------_-_- ----_-_- ----_-IL__-_-r -__-_ - _- - Ti _I--�iIIIiII(Im--l----------------5p� (EXIST.)o I'I1 III I +'+tjj�---------------------------- ---------------------------------- NNI N --r NEW EXIST. (EXIST.- PR IIj'lIl �'IIL1 + NA iWl,-103 IiII� --1_IIIiIIIIII1'l,lII,1IIII1I�IIIl1III - -I--=IiI1iIIiIIIII'lIl1lIIlIII'-IlIi1iIIIiIIIII --=-iIiIIIqIIIIIII-IIIII ,lI,lIdIIIIIII IiIIiIlIIIIIIIIIII --=�+- T1}IiIIiIIII1IIIIIII =-1 IiIIIIIII1IIIIIIIIIIIIiIt,I'III'II'IIII,III' Wi y j iiijw LB(LO_1)2043-- ---I-----------------------------------r------I ----------------------------------J T - -- -_T- --ter--- _ _ __ _ _ _ _ _ _ _ __ _ _ _-I _ _-r- _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _T-- ----1 J-_ __——_ ______-_-_____-_-_-____—_L�- _ _ _—_ _---_--_ _- ___- --$ --__ - —_ _ __ — —_ _— 3-.216 B(OW-1)575 L____J L; W 1 IIIIIIIIIIIIII IIIIIII IIIIIII M T 4"-.237 B(FG-1)2050 1 T - --------------- --'----------------------------r------------------------------------------- — -------------- E _ Z__ — j ------------ _——=-—' J — _ r _ =- — _---- _- ----------- E1I -___==_====___=_======_==_======_=-- t__ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ------ II1IIIjI�mjI 1111 -- -- -- --- — — -- -- —— -- ---------------------..-. -------- ------------ - - - - - - -�- ----_-------- ------------ - - - - - - F--f - - - - - - - - - - - - - - - - - - - - __— -- -�' -LLJ —— = = _=—�= = --- = = = = = = o Om EXIST. 2" FUEL GAS EXIST. 2" RAW WATER O I EXIST. 2" SERVICE AIRz EXIST. 1" PILOT AIR N EXIST. 1' DISCHARGE GAUGE W EXIST. 2" SUCTION GAUGE WN �wmfw DRAWING LIMITS S 8+62'-10" L.J. - — � III1 II II II III NOTES: 1. CONTRACTOR TO DISCONNECT EXISTING METER RUN AND INSTALL ABOVE GRADE CONDUIT PULL BOX ON EXISTING CONDUIT. EXTEND NEW CONDUIT FROM PULL BOX TO NEW METER RUN LOCATION, PULL NEW WIRE FROM EXISTING FLOW COMPUTER TO NEW METER LOCATION AND RECONNECT. i,lIIIItI IIIi�pI;I,I,t,iU IIIIl 11'1 W I'I'llIl1IIII�I'iIIIIiiIi1IIIIIIII InIvIiiiII�mIIIIIIIIIIUIjtIIIII�IC IlIliiIIIIII1II IlU�II�II IiIIIII, IiIIIIIIa I lUCII�IIiIII1I, 11 11 181 1 B ER I N G DRNE - SUTE 400 UNIVERSAL R.O. BOX 570248 ' ENSCo, "G HOUSTON, TEWS 7]25]-0248 DWG. CHECKED APPROVED WORK ORDER NUMBER -- - --- ---------- STATUS BY DATE BY DATE BY DATE 52213 Florida Gas Transmission Company P.L. OR STA. ACCOUNT NUMBER Houston Texas 1994 CONSTRUCTION PHASE III EXPANSION BREL'Y A BY oaTE COMPRESSOR STATION N0. 20 °-,- -- --- ---- -- - DESSIC 9 2 93 BID I- DRAWN As 9 2 93 ELECTRICAL/INSTRUMENT 1 ISSUED FOR CONSTRUCTION RLS 1/1/93 CONSTR. As BUILT FUEL GAS AREA o ISSUED FOR BID AS Is o3 93 -- - -- -- ���RE — FT. PIERCE FLORIDA - ---- -�- ----- ~ - -- ~- t _PLOT DATE _ __---- crtE No. N0. REVISION - DESCRIPTION BY DATE 'CHK'D APP'D CADDS DWG. S22138 2035611 SCALE 125 1" I 1110PAW Hit 130 1" TUBING ROUTED LOW GRATING EDGE OF CONCRETE TRENCH C-2005 (SEE NOTE 5` -- -- UNIT PANEL ?0.35.644 AIL- —hl- iE 124 TE � _ 053 #t j l 22 120.35.644 - 1 BULKHEAD BAR #2 (FOR CYL 2 & 6 UNLOADERS POLYLINE) _ _ dT r, I DT53 BULKHEAD BAR #3 - 1 (ARRANGED VERTICALLY) ' ll--m- STAINLESS STEEL LINE ( ) i( l 71 120.35.642 1 TI MOUNT TO EAST WALL 514 OF COMPRESSOR BLDG., 1 ROUTE CAP TUBES TO TI SUCTION & DISCHARGE LINES / 501 SEE DWG. 120.35.613 Pdl SZ120.35.641 501 INCLINED LADDER VE I•. COMPRESSOR_ — UNIT CRANKSHAFT ,� E. 3+46'-0 113 20E 0 .� 2.. 119 2' JB1 M120-N N0TE 3 _SUPPORT AS REO'D I— ------------------------ 1 iwAffltflt I1111 "C BULKHEAD BAI� #1 (FOR CYL 1 5 UNLOADERS Pj LYLINE) •>> VE DOWN TO VENT/PURGE 24 FAN VF-201 1" SEE DWG. 102.35.613 131 1" EWA v -9 10 3!313) \_J ABOVE GRADE EL. 18'-1 1 /2" 115 1. 112 JB3 111 1 (BELOW) 1332 o- u� I JB2 °, l AIR DRYER M-20 0 TCV 566 D20 1" 22 1" 110 ,��.*'� ,.I 1 1 HS 203 .f -UP TO VENT FAN VF-203 28 1 •' r all T E 1.. 001)_ 1 e� LSLLq , r } 07C. i 120.35.641 073 127 ! z j w VE 85— 20.35.642' - Z JB4 �110 f \ 1.-- PSV LSLL 561 ABOVE GRADE EL. 11'-4 3/4" i 2020 569A 105 Uj TE 1'h If ' a z :2083 j cj' 5 120.35.641 TY 1 ii 569 j F-2020B ' I F-2020A I. EDGE OF CONCRETE TRENCH � HS 202 `-UP TO VENT FAN 25� VF-202 1" I r T:. i i WORK ORDER NUMBER Florida=� DWG. CHECKED APPROVED m STATUS BY DATE BY DATE BY DATE S22138 FiaS I" Slott 4t1'ij�a�t - - - -- U% _-. ...-___ _ P.L OR STA. ACCOUNT NUMBER_... 1994 PHA CONSTRUCTION - — - --- - _ PREL'Y — -- — - — — EXPA BY DATE COMSE IN NSION DES IGN DM 8/17/93 PRE _ - BID _DRAWN 1<JH 6 11s3 ELECTRICAL/INSTRUMENT PLAN 1 ISSUED FOR CONSTRUCTION JCT 11/1/93 CONSTR. --- ----- ---- --- -- =�- 1 -�BN`T - COMPRESSOR BUILDING - ABOVE FLOOR MICRFLM 0 ISSUED FOR BID KJH 9/03/93 -- — — -- - - -- M1cRFW - - -- FT. PIERCE, FLORIDA -- -- —_- - -- PLOT DATE FILE NO. NO. { REVISION DESCRIPTION BY DATE CHK'D APP'D CADDS DWG. S22138 2035612 SCAE 1 4 —1'-0" l 1 51 1 BERWG DRIVE - SUITE 40C' VA P.O. BOX 57024E HOUSTON. TEXAS 77757-0243 (713) 977-7770 ENRON 'IA'FELINE DRAWING NUMBER 120.35.612 —?- — — — -S TO ELP-1 ESD "77;-- ____ STA. #6 1"C. 3 #12 THWN 924 FOR CONTINUATION SEE DWG. 120.35.616 90 1" I I 130 108 107 105 117 120 119 116 113 131 124 11 <a= Ll l II 125 II 1" II 18 II _ 1 UP TOI(FUEL GAS METERING II II II012' II - II- 2,. svo svo svo 501 514 519 SVO SVC SVC SVC SVC i 502 501 514 519 518 - _ _ ZSO ZSC GOV V:��L-Y 514 514 51419 120.35.643 I ❑ ❑ ❑ L31 ❑ ❑ ❑ ❑ 3 1 i 51d4 I -- - --1 - 44 - JB-1 \ II ��-, II -- \ E07821 1 I I I I I r II DRAWING LIMITS (EAST BLDG WALL) E 3+76'-5 1 /2" F- -- Ui FOR CONTINUATION E 1" 110 SEE DWG. 120.35.615 I 114 1" II 100 101 1 115 112 1%z iII 132 110 127 LO-- J - TE 124 » 1" — — -- - — - 503 1 Yz" — — — — — — UNIT PANEL C-2005 -fir IIII III I IIIIIIIIIII I = I III 503-3 � TE 1_ _ I , 2�� 1�_T1 _ 118 - - I 132 I I I _ 1 I IIIII III11� i -- - 4-- j ITc IIIII II II I I 124 �� 511 - 1112 I IIIII I I III I � 1 %2 ," 1 114 � IIIII II III I I 1 IIII III I „D 107 pl 22 120 35 644 NOTE 5 1" o H TI 563 P-565 5616 TE TE 201 I I I ( I GC-2005 514 21 120.35644 UP TO PS t 19 113 LL 2073 127 NOTE 5 NOTE #2 2' 2.. O 1' 5114 17120.35.642 o PSLL NOT #3 IIII 2017. , . — ___ — --Q �._ _. _ - — 120 , ' 1-2 1� 1 511E 4 \r 0 - — _ I _ 1 -- FF_2W4 FIELD TO SUPPORT & SECURE INSTR. TRAY I I y I 5H PT I I� _ I L 117 - _ _._ �1 20 V-5f1 1 I I I II AND TUBING AS REQ'D. 1 I 514 120.35-.b4; � - I. D.�8 120364i JB-3 DISCHARG 1 1 1 PdlJB-2 8 120.35.E 1 -- NOTE 5 116 501 D. SUCT 1•� \3 6" 10 I III 1 1 I 24 I I I I ZS0 ZSC GOV I I I ZSO ZSC GOV I I 1j 502 502 502 1 1 1 518 518 518 1 PSLL PT 0 120.35.643 1 1 1 501 501 1 - I I I 20120.35.643 12 120.35.64 ZSO ZSO ZSC GOV ZSC ZSO ZSO GOV II I I II 501 5018 501 501 I 519 519B 519 519 II I I II 19 1120.35,643 1 19 120.35.643 I I I I II I i II I I I I II I i II i I I I II I 1 II I I I I II I I II I I I I II I 1 II I I I I II 1 I II I I I I I it I I II I I I I II I I II I I I I II I I II I I I I II I I it I I I i II I 1 II 1 I I I II I I II I I I I II I I II J NOTES: 1. FIELD TO VERIFY UNDERGROUND CONDUIT DUCT BANK CLEARS UNDERGROUND PIPING BY 1'-6". 2. FIELD TO ROUTE & SUPPORT PIPE TO UNIT PANEL. SEE DWG. 120.35.644. 3. ROUTE CAP TUBES TO INSTRUMENT MOUNTED 4" ABOVE GRADE. SEE DWG. 120.35.612. 4. SEE DWG. 120.35.612 FOR CONTINUATION OF ABOVE FLOOR CONDUITS UNLESS OTHERWISE NOTED. 5. CONDUIT TAG PER MAIN FEEDER. IJI !>!: �: : i C E-2020 F-2020, - FLEXIjB�LE CONDUIT TO AN OR — — — _ _ — — — — — — — 26— I TE 503E-4 503- _-� 2 1" --------_-------_ UP TO HS-202 FAN CONTROL 25 5011 r7L 20.35.642] I I VENT/PURGE 1 1 VENT FAN VF-202 1/'NOTE #3 I I I I FAN VF--201 1„ SEE DIN. 120.35.612 MOUNTED IN 24 r- pl I DUCT BELOW N 501 _ I I I FLOOR 12 a ' NOTE #2 I I ( I SEE DING.OVERHEAD 120.35 616 1.. 6 I i I I _24 I VF-201V"AUTO" "AUTO" 113 m 1� SEE DWG. 120.35.612 120V RECPT. 14 SEE DWG. 120.35+616 29 S P z DRAWING LIMITS (WEST BLDG WALL) E 3+12'-8 1 /2" Jr �. C 1911 9CRING ORW - SUII MO U N leesaoR C?t- Po HOVSiTON, OX 55FJ(/.97)25]-D2" (713) 977-)DO DWG. CHECKED APPROVED vurcn unuen nuw.uert � � � -------- ---- -- - -- - - STATUS BY DATE BY DATE BY DATE S22138 Florida Gas Transmission Company P.L. OR sfw ACCOUNT NUMBER Houston Texas EN RON ---------- 1994 CONSTRUCTION PHASE III EXPANSION GAS PIPELINE -- DESIGN - -- DATE --- - -- - - - - - -- PREL'Y -- - - - - - - -- - ------ COMPRESSOR STATION NO. 20 GR P CMH 7/2_/93 - -- - -- - - BID - -- - — _--- - --- -_--- DRAWN . KJH 7/29/93. ELECTRICAL/ INSTRUMENTATION 1 ISSUED FOR CONSTRUCTION AS 1/1/9 CONSTR. - - -' "may AS BUILT ---- COMPRESSOR BUILDING UNDERGROUND AREA '— 0 --- -- --- -- ISSUED FOR BID --- AS } 9/03/93 - - -- - - - - -- PLOT DATE. MICRFLM MICKLM FT. PIERCE, FLORIDA -- -- --- - --- --- ~!- NUMBER - No. - -- REVISION - DESCRIPTION [--__- BY DATE - CHK'D - APP'D CADDS --- -- - ---- DWG. S22138 2035613 ALE -No SCALE _ - 1 4'-1'-0" rDRAWING 120.35.613 21 120.35.644 22 120.35.644 W� w I 1 a E*r _ H AUXILIARY' 4: I I I ce 11.1 O U Q U) I—zWz BUJ �0zn O LJ �o�o _ 1 p n z Q w Q % Uf)mQ U 3E M XOO r--- .------- AIR I COMP. ON wI F �f------------- 3A Z� (� < l AIR n 3,. S COMP. I( JI 38 4 I 5 Pp� I S L 1/V -------� 1 3" o� 8 BREAK OUT CONCRETE (NOTE 44) II 2^ UNDER NEW MCC TO WALL RUN CONDUITS UNDER p p OUTSIDE BEAM 9 q�q�Q 1 —_ 3/4„C, 1 TRI27 #18 SNILD (NOTE #1)I I I I I IIIII III % `s i -i 4'f - -- L-- —A & PORTABLE NEW 200A 480V 30 DISCONNECT { I) / I I II I _ C 3A 3B 4 GENERATOR RECEPTACLE (NOTE #1) --_){ -1 II{(I) 4-3— 3— 11/ S 2A 2B STUB OUT906 Ii IIii %V 73 71 10---6 77 903 3 i.T ,. 1�V3 3" 32. 2 EXISTING TO SWITCHRACK #1 TO GAS AFTERCOOLER I I I (III I I 72 70 76 75 74 905 (ABANDONED) I ( I IIII I I 1YV - 1" - I ID2A 2B I I III B DB TO PBS#2 SEE DWG. 120.35.615 it J�-------TO EXISTING PBS-II-1 FOR J FEEDER TO SWITCHRACK #II-1 TO 800A SERVICE �{ h (NOTE #2) MAIN BREAKER ( { DWG. # 120.35.615 DWG. UHtUKtu - - STATUS BY DATE BY EXISTING llm.. RECTIFIED 440 SINGLE PHASE BY 1 DATE PREL'Y --- - -- - - -- BID - --- - --- -- DCM 11/1/93 -- CONSTR. --- -- - -. -- ---- KJH 9/03/93 -- - - --- - _-_ - PLOT DATE CADDS - - --- - BY DATE CHK'D!APP'D DWG. S22.138 E 2035614 21" x 21' SHOCK k (TYP. OF _S22138 P.L. OR STA. ACCOUNT NUMBER 1994 CONSTRUCTION 8Y DA7E DESIGN DM 4,1L93 DRAWN AS 4L�93_ AS BUILT MICRFLM MICRFLM ME NO. SCALE MWSEE DETAIL DWG. 120.1 3 NEW GAS DETECTOR. i. TO GAS DETM JUNCTION. BOX )N NTS EXISTING WALL 1. PHASE III CONTRACTOR IS TO MOUNT" 200A FUSED SCONNECT WITH 200 AMP PORTABLE GENERATOR EPTACLES AND ROUTE TEMPORARY FEEDER, ONDUIT #9, 2"), TO EXISTING MCC #1 PRIOR TO REMOVAL OF THE EXISTING 250KW STANDBY GENERATOR FROM THE AUXILIARY BUILDING EQUIPMENT ROOM. THE TEMPORARY FEEDER SHALL BE DISCONNECTED AND REMOVED AND A PERMANENT CONNECTION INSTALLED TO THE NEW ATS (CONDUIT #8, Z) AS SHOWN, WHEN THE NEW MCC AND STANDBY GENERATOR HAVE BEEN PLACED IN SERVICE. 2. PHASE Ill CONTRACTOR SHALL INSTALL A NEW CONDUIT (#7, 3") FROM NEW MCC #2 TO EXISTING PULL BOX II-1 TO REPLACE EXISTING la; CONDUIT #7 FROM EXISTING MCC #1. EXISTING CABLE IN EXISTING CONDUIT #7 IS TO BE PULLED BACK FROM MCC #1 TO PULL BOX II-1 AND REPULLED INTO NEW CONDUIT #7 TO NEW MCC #2. EXISTING CONDUIT IS TO BE ABANDONED IN PLACE BETWEEN PB & BLDG, AND IN REMOVED INSIDE BLDG. 3. CONTRACTOR SHALL REMOVE EXISTING 250KW STANDBY GENERATOR, EXTEND OR REPLACE CONCRETE FOUNDATION, RESURFACE CONCRETE AS REQUIRED AND INSTALL THE NEW 300 KW STAN GENERATOR UNIT. SEE ABOVE DRAWING ° AND 120.1 OLD FOR REQUIRED FOUNDATION. PHASE III CONTRACTOR SHALL DISCONNECT THE EXISTING UTILITY POWER FEEDERS AND ASSOCIATED CONDUITS TO EXISTING MCC #1 WITHIN THE BUILDING I AFTER NEW MCC #2 HAS BEEN INSTALLED AND IS IN I SERVICE AND THE NEW FEEDER TO EXISTING MCC #1, (CONDUITEXISTING �RVICE CONDUITS NTONMCC L#1 ARE ED MTO C BE #2 ABANDONED IN PLACE. LEGEND - - - - NEW UNDERGROUND CONDUIT --- NEW ABOVEGROUND CONDUIT — -- EXISTING CONDUIT 1�4 r. 1811 Bln, 0•i.. — Suite 4_ UNIVERSAL P.O. Bov S7 024B } ENSCO. INC. Hou'Wn.Te .. 7MI-0348 S \e_ Florida Gas Transmission Company Houston Texas p� � PHASE III EXPANSIONw'w� �r COMPRESSOR STATION NO. 20 'LU'► AUXILIARY BUILDING AREA FT. PIERCE, FLORIDA DRAWING NUMBER 120.35., 0 0 0 0 0° 0• O N. S 1 +00 Ld w w S 3+00 S 4+00 0111=916 S 6+00 S 7+00 w0nkfuf S 9+00 A 1 L (1 r. S I� • �I , I . r 3} a � o 0 0 0 17 It Ln W W SERJICE POLE ' W. NEW 800 AMP, 480V METER RACK SERVICE DISCONNECT, SEE DWG. 120.35.624 FOR DETAILS. I UGM-1 I ) I I I G is 0 o HWY 68 0 + } ORANGE AVE. (o . t` 00 W W W 10) 3TING 3" COM)IJIT H 3, # 250MCM ) t, #1/0 . 0 PIPELINE BLDG.I J 0 0 0 TM Eli RESIDENCES �i IJB - INSTRUMENT JUNCTION BOX, SEE INSTRUMENT DRAWINGS FOR DETAILS. FL 35' HINGED MAST WITH 3-400 WATT HPS FLOODLIGHTS, ARROW INDICATES DIRECTION OF BREAKOVER, SEE DETAILS ON DWG. 120.35.635 CDB-1 CONDUIT BANK DETAIL. SEE DWG 120.35.619 FOR CONDUIT AND TRENCH DETAILS. ® GROUND TEST WELL - SEE DETAILS ON DWG 120.35.622. ® GROUND ROD - SEE DETAILS ON DWG 120.35.622 ----GROUNDING CABLE - 2/0 UNLESS NOTED OTHERWISE SEE NOTES 1 & 2 GROUNDING CABLE CONNECTION - SEE GROUNDING DETAILS ON CONDUIT CKT # a X XX CONDUIT IDENTIFICATION CONDUIT SIZE UGM-1 ❑ UNDERGROUND CABLE MARKER NOTES 1. ALL GROUNDING CABLE WILL BE #2/0 AWG STRANDED COPPER WITH GREEN TW INSULATION UNLESS OTHERWISE NOTED. GROUND CABLE WILL HAVE A MINIMUM OF 18" COVER 2. EACH MAJOR CONDUIT BANK WILL BE PARALLELED BY A LUBE Lu J MAIN #2/0 AWG GROUND CABLE. GROUND CABLE WILL OIL RUN WITH CONDUITS BUT WILL NOT BE CONCRETE ENCASED. SEE DWG. NO. 120.35.619 FOR CONDUIT BANK DETAILS. TIE TO .EXISTING. f?BS ,-4 . o . . . . . . . 'p F.H.' #3 GROUNDING GRID • 3. FOR GROUNDING DETAILS SEE DWG. 120.35.622 II L� 7 4. FOR FLOODLIGHT DETAILS SEE DWG. 120.35.635 sum PM 0 DITCH X 5. FOR INDIVIDUAL CONDUIT ROUTING TO MOTORS, CONTROLS, LuJ INSTRUMENTS, ETC., SEE INDIVIDUAL AREA CONDUIT PLANS. DITCH - 1t --- o o 6. MOUNTING DETAIL FOR FIELD LIGHTING PANEL & - fz � 0 TRANSFORMER SEE DWG. 120.35.621 L) 0 0 WASH WAREHOUSE BUILDING PAINT t� n' ' . ' ' . �� PAINT 7. FOR INCOMING POWER DETAILS SEE DWG. 120.35.635 RACK �L___1 w COMPRESSOR s BUILDING 12s (EXISTING I" MAIN CONDUIT DUCT BANK & BRANCHES SHALL BE 1'-0" EXISTING CDB4 _ _ _ m RA MIN. BELOW B.O.P. ELEVATIONS WHERE APPLICABLE. STATINEW PBII-2 PANE�N - - CONTROL BLDG. ALL AREA CONDUIT PLAN DWG'S SNOWING UNDERGROUND PBII-3 -------s_�__ PBS-5 p LLL111JJJ BLOWDOWN I �I CONDUIT ,ROUTING SHALL BE VERIFIED BY CONTRACTOR SILENCER �I )I o FOR CLEARANCE OF PIPE SUPPORTS & OR OBSTRUCTIONS J BEFORE TRENCHING. REMOVE CONDUIT DUCT BANK AND ( y—---f — �� 'SE III CONTRACTOR SHALL INSTALL A NEW CABLES FROM PBII-2 TO PBII-3 -- — 1-2"C 14 #8 & 30 #1?_ CDBS NDUIT (#7, 3") FROM NEW MCC #?_ TO AND PBII-3 TO PBII-4 p 2-1"C- EXISTING (PULL BOX II-1 TO REPLACE EXISTING REMOVE PBII-3 I �� ONDUIT#7 FROM EXISTING MCC #1. EXISTING REINSTALL SAME CONFIGURATION 1MABLE IN EXISTING CONDUIT #7 IS TO BE PULLED OF PBII-3 AND CONDUIT DUCT a II _ _ BANK FROM PBII-2 TO NEW PBII-3 'I II _ CDB6 (NOTE 11 -FUEL GAS AREA ACK FROM MCC #1 TO PULL BOX II-1 AND REPULLED AND NEW PBII-3 TO PBII-4. J I I —j PBS-6 I I I. SEE DWG. 120.35.611 NTO NEW CONDUIT #7 TO NEW MCC #2. EXISTING REINSTALL CABLES. i 0U N I I `�- T- ONDUIT IIS TO BE ABANDONED IN PLACE BETWEEN PB & -+ LDG, AND REMOVED INSIDE BLDG. CO"" STUB UP & CAP FOR I I P FUTURE SWITCHRACK 1 TOP OF 'CONDUIT DUCT BANK BETWEEN PBS-6 AND III EXIST . PBII-3 TO I i" • I `- `� n- I ( i UNIT 2005 PANEL SHALL BE 6'-0" MIN BELOW GRADE BE RELOCATED I SUMP' I � soy. 300 apt 0. TO ALLOW FOR FUTURE CONSTRUCTION OVER DUCT BANK. PBII-4 i, ' ` I - --- FAS III COMPRESSOR 1Yz 2" 2" I ] BUILDING - 30 37, t0 1CDB8 ., TO GAS SCRUBBER nil I I SW1ITCHRACK #4 to s l0 O O >.. 0� ARt A SEE DWG I I I �_- _�CD81 CD 10 3., 3., ill/ 0 35.608 _ CBS--9 _ PBS-8 -• - CD69 - � GD612Y - - ,011 BERIN )Rb - 5UITE 400 _ /I ETNSCO. INC. NOUSONJFE 77257-0248 �� �.•.— l�'V IVL P0. 80% 570248 J 1I1JB . 3 1 _ - �� (I13) 927 D 300 _iot �.. DWG. CHOCKED �VED._., .w. �BER �! 3 ^APPR WORK ORDER NUTAdER • • •—__-.____ __ _—_-....___—_-_- —. -- STATUS BY DATE BY D.41E BY DATE S2Z138 Florida Gas Transmission Company P.L.OR STA. /ACCOUNT NUMBER _ _.. I -- _-- --_ _ _-- Houston Texas L _ ------ - - - { -- -_ ---- _ r 0 --. -._ _ __. __- _-_-- --_ - t 1994 CONSTRUCTION 306 - - -- - — -. -- -- - PREL'Y- - -- -- — —BY - ATE_ COMPRESSORPHASE STATION NO. 20 O / - — --- - -- -- -- - BID DESIGN DM 0 /07/93 €!'L�, . oRAw"- _ KJH 08/07/93 ELECTRICAL CONDUIT ROUTING, TO 30" DISCHARGE -- - - --- --- - - - --- -- - - - �./ AS BUILT \\Q\ \\\\ 1 ISSUED FOR CONSTRUCTION RLS 11/1/93 CONSTR. - -- - �i - --- ---- GROUNDING & FLOOD LIGHTING PLOT PLAN VALVE AREA SEE -_-_ _. _ _ _ __ - __ _ _- MICRFLM - DWG. 120.35.634 0 -MI ISSUED FOR BID KJH 9/03/93 - - - _-, - - - CRRA- - -- FT. PIERCE, FLORIDA DRAWING NUMBER - -- _ PLOT DATE: FILE No, 120.35.615 NO. REVISION - DESCRIPTION BY DATE CHK'D APP'D CADDS DWG. 1S22138�E�2035615 Sf.A E 1" = 50' r- i WATER TOWER N I ?r_ME nn. 0 I a \ 12' ROLL -UP \ FLP-1 3 SLOPE / / J / ei i 1 �J ELPLP1 .w Ll � t I�IIHI,II,;j. UL�Gss'' o-- -- 1"C_3#12 THWN — ESD STA #5 BLDG'- - S 7+67'-9" 20'-4" ]RUCK WELL UP1..-4 /I' O - --H H \ 3 i P1 -5 err � H j ifrjL -1 (1�1TWi19WA 1 120.35.E �\ j-f TO ESD STA #6' JAI J +_-- 1"C, 3#12 TF 8 120.35.623 LP 1-9-1 1 LP 1-9,1 1 LP1-9,11 LP1-9,11 LP1=9,11 TYP OF 15 - - H H 5 120.35,623 3 120.35.623 TYP OF 5 ��� _. TYP. 4 --- - -- / E � _ �x INSTRUMENT LP1-2 E I- 120.35.623 { AIR DRYER CEP-2 ------ - 3 / RFD-2005B 1 TYP OF 7 - - 7 t � JF--2005D / f r f7D 77 .,� — 12 LP 2 `y I 1 C, 3#12 THWN INTAKE EXHAUST INTAKE "� J, E fr TO ESD STA #7 FOR CONTINUATION - DWG. 120.35.609 I i / TYP OF 5 J Ik - -�j--5 TO ESD STA #8 1"C. 31112 THWN DWG. GNtLKtU _ _ ANYKUVtU ^"""�`^ -- -- -- - 1 ---- --- - - STATUS BY DATE BY DATE BY DATE S22138 PREL'Y 1994 CONSTRUCTION BY DATE DESIGN --- -- -- l - --- -- - DRAWN - BID DM 0 1 1 KJH 08110/ 1 ISSUED FOR CONSTRUCTION TTB 11/1/93 Aj_ y AS BUILT -- --- - -_— CONSTR. wicRFLM — - - - 0 ISSUED FOR BID --Kill 9 3 93 - -- - - - - Mlckffm - -- - - - - _ -- — - - /_/.... PLOT DATE: ___ _ _ _FILE NO, _. NO. RIVISION - DESCRIPTION BY DATE CHK'D APP'D CADDS DWG. S22138 203561E SCALE E LEGEND 250 W MH PENDANT MOUNTED LIGHTING FIXTURE 208 VAC 100 W H.P.S. WALL MOUN11'? IGHTING FIXTURE 120 VAC \ ' EMERGENCY LIGHT 150 W INCAN. WALL MOUNTED r LIGHTING FIXTURE 130 VAC (EXTENDED LIFE BULBS) 120V RECEPTACLE II II (EXPLOSION PROOF) ' ® FIRE & GAS ALARM J-BOX & DIGITAL CONTROLS. 1-8 t INDICATES CIRCUIT OR CIRCUITS USED \— INDICATES PANEL ID. -XX �- DWG. DETAIL IS LOCATED ON ` REFERENCE TO DETAIL �G GAS DETECTOR FLAME DETECTOR --- CONDUIT ABOVE GROUND ----- CONDUIT BELOW GROUND ELP _ EMER. LTG PNL FLP = FLOOD LTG PNL 9 SWITCHRACK #3 LP = LTG PNL ® SWITCHRACK #3 BRANCH CIRCUIT CONDUIT SCHEDULE O1 3/4" SEAL-TITE, 4 #12 THWN O2 1"C., 4 #8 THWN Q 3/4%., 3 #12 THWN O4 3/4"C., 4 #12 THWN O 3/4"C., 5 #12 THWN © 3/4"C., 6 #12 THWN O7 3/4"C., 7 #12 THWN ® 1"C., 8 #12 THWN O9 1"C., 9 #12 THWN 10 3/4"C., 3 #10 THWN Ol 3/4"C., 1 TRI #16 W/SHLD O3/4'C., 2 TRI #16 W/SHLD �3/47C., 2 PR #16 W/SHLD 1"C., 4 PR #16 W/SHLD 33 1"C., 6 PR #16 W/SHLD NOTES: 1. EAST WALL OF COMPRESSOR BLDG. IS AN EXPANSION WALL. NO ELECTRICAL CONDUITS OR EQUIPMENT SHALL BE ATTACHED TO OR ROUTED ON THIS WALL. 1--)— 1811 KRAG DRm — suer[ s00 _R AI_ PO BCx 51D248 HDUS ONJEL 5 ]125]-0248 (JU) 977--))70 PHASE III EXPANSION ILMAM3 PIPELINE COMPRESSOR STATION NO. 20 ELECTRICAL COMP. BLDG. LIGHTING, FIRE/GAS DET. PLAN FT. PIERCE, FLORIDA DRAWING NUMBER 120.35.61E 1 Florida Gas T Company J . 1 1 /2"--m- II II I) II II II II II II II II II II II li it II II II II II II it II II II II II " (INSIDE OF BOX) B" (INSIDE OF BOX) - PLAN SCALE: NONE - ---- DIM. "A„ & „ B„ i /-Ll/4!' STEEL PLATE i 1 /4" FF -- ----- D a 3"x2"x1/4" ANGLE - SECTION "A —A" MITER AND m SEAL WELD AT SCALE: NONE CORNERS. WI 0 T M u) cS rP 0 4 /2" 9 a L �3--T/_ SEAL 18" II IICH 5/8" HOLE —� S EAL 1 /4' WELD TYPICAL OF (4) „ r, (INSIDE OF COVER) Imo- t OF COVER I II BREAK LINES I II i � I ,I �I r , l I I I I 3" TYP. DIM. 2" TYP. DIM. BOX COVER SCALE: NONE { RA T 9. I rs m III I F. I r- TAG NUMBER IT B PULL BOX STATION DIMENSION C D E SCHEDULE F G H PBS-2 4'-5 1/2" 2'-5 1/2" 4'-3" 2'-6" 3" 4'-6" 2'-6" 12 GA. 1 REQ. PBS-3 2'-5 1 /2" 2'-1 1 1/2" 2'-3" 3 3" 2'-6" 3' 12 GA. 1 REQ. PBS-4 2'-5 1/2" 2'-11 1/2" 2'-3" 3' 3" 2'-6" 3' 12 GA. 1 REQ. PBS-5 4'-5 1/2" 2'-11 1/2" 4'-3" 3' 3" 4'-6" 3' 12 GA. 1 REQ. PBS-6 3'-11 1/2" 2'-11 1/2" 3'-9" 3' 3" 4' 3' 12 GA. 1 REQ. „ G„ y (INSIDE OF COVER) 1/2" DIA. ROD WELDED TO COVER. (REF. BOX COVER DIM, THIS DWG.) 12 GAUGE—i I— 1/2" BREAK HEIGHT /- '1 "1 \� ------------------- WELD 3/16 t1l /2" REFERENCE DRAWINGS - 120.35.619 PULLBOX STATION STUB --UP DETAILS -- 120.35.615 COUNDUIT ROUTING, GROUNDING & -- - - --------- FLOOD LIGHTING PLOT PLAN 1 ISSUED FO R CONSTRUCTION 0 ISSUED FOR BID NO. REVISION -- DESCRIPTION PBS-8 3'-11 1/2" 2'-8 1/2" 3'-9" 2'-9" 3" 4' 2'-9" 12 GA. 1 REQ. PBS-9 - 2'-11 1/2" 2'-8 1/2" 2'-9" 1 2'-9" 3" 3' 2'-9" 12 GA. 1 REQ. 1 - --------------� 2" x 1-1/2" x 3/16" ANGLE FRAME, (MITER & WELD AT CORNERS). SECTION "B—B" BOX COVER SCALE: NONE - 3/4" LIP V�T SEAL WELD COVER PLATE TO COVER FRAME ALL AROUND DWG. CHECKED APPROVED WORK ORDER NUMBER _-- - STATUS DALE BY DAiE BY S22138 BY DATE _ PREL'Y - - - P.L OR StA ACCOUNT NUMBER 1994 coNsTRucnoN --- BY DATE - - UID DESIGN DM 5,5/9 DRAWN AS 515f -_-- DCM _- 11/1/93 CONSTR./�,�1 As eulLr - MICRFLM -MicRFtM FILE NO. sca _ -- ---- _. _ ---- -- NONE DDK BY 9/03/93 DATE CHK'D APP'D - - CADDS PLOT DWG. — DATE: ---- 522138 - --- 2035618 - -- 1. ALL MATERIAL ON THIS tHALL BE ASTM-A36 OR EQUAL UNLESS NOTED 0 ISE. 2. PULL BOXES SHALL BE OF ALL WELDED CONSTRUCTION UNLESS NOTED OTHERWISE. 3. FABRICATOR SHALL FURNISH ALL MATERIAL SHOWN ON THIS DRAWING. 4. PULL BOXES SHALL BE HOT DIPPED GALVANIZED AFTER FABRICATION. 5. EACH PIECE OF EACH BOX SHALL BE TAGGED WITH APPLICABLE TAG NUMBER BY MEANS OF PAINT ON THE INSIDE OF BOX. v x %nr 1 ten - sv2e eoo UNIVERSAL P.O. Bo.ox 57 9c248Ya8 evsco INC. e t m T <s) a'aa Florida Gas Transmission Company Houston Texas Rw im K, ev1A PHASE III EXPANSION GAS pM"1,', COMPRESSOR STATION NO. 20®U PULL BOX STATION ASSEMBLY AND DETAILS FT. PIERCE, FLORIDA DRAWING NUMBER 120.35.618/'l\ I PBS L2 3 6" 6" 3" 3" 6" 6" 6" 6" 6" 67� 3" Y 1 1 /2„ rr ------ 3" _ i- - - - - - - - - - - - - - - -- - - - - - - �. 906 9' TT 72 73 ` _ _ _-- 1 /z" 1 /z" • 6„ a °: 9031 70 71 1%z" 1•• 1" - - -• - o 1 /4" g" _j BARRIER 76 10 - - -: --- C w • 1 %i' 3" ft� 6„ a 0 903 70 _72 74 77 75 6 - � w ` 6' O v 906 905 76 75 71 73 74 77 1%z" 1%i' 1%z' 1" 1" 2" 1 1 ' ° � j ° -- - I I I I I I 1 1/2" ! i l j l i LiJ TO PBS #3 FROM PBS #2 TYP ALL PBS -{3 120.35.622 1 1/2� \ (/ 1 1/2" ` 3 6 6" 6' 6" 3" % - / • 3rr PBS 3 906 905 � 3,. \` 1Y2' 1%2" ` 903 70 1 /4" ° BARRIER 12" 903 71"0 a - 1 1 6„ 906 905 10 4 I I I i I 6 a 11 „ _I I I I i I I 1 I I 1 TO PBS #4 FROM PBS #3\ 1 1 /2" 1 i 1 1 1 /Z' 3" 6" 6" 3" 31 6" i 3 I I I I j�=� • '° 1 �< 1 4 PR5� '4 �� 1 1/2" I ,I 906 905 j " 3" 3 3I 903 70 1" 1 /4' BARRIER 903 70 1112' 1" 906 905 I 6 10 1 %z" I I 1 1 I I I I I I 3" 6" 6„ FROM PBS 5 G I t 1 1/2-" {� I I I j�'�'6 6. 1 6„ I 6" 1 3„ 3„ 1 3" 1 3" PBS 8 I I I 1 1 1 1 I I Ir 1 1/2„ - 1 I I' 6" 777777907 302 SP 10 i SO -�- - - - - 1 %z" 1 %z" 2" 1 %z" 3" 1 , Ira _ 300 302 301 303 007 40 1 /z S' 1 a 6„ 1 /4" (n_301)303 a --- - - - 2' 2 BARRIER 0 �• SO 40 6,. -{_----------------------- - 1,. 1„ 6„ - - - - - - - - - - - - - -__ 10 6 3„ 3,. TO PBS #6 -- —tea_ -- 1 1/2" FROM PBS #5 TO SWITCHRACK #4 SEE NOTE 1 1 1/2" I I I I I 1 3" 6„ 1 61, 6„ 61 ill 6" n „ 1 1 /2„ / � ' � I I I 1 1 1 /2" 6"� 3," 6� � 66' 6„ 6 i - 6„� 3„ 3„ 3" 1 3„ t 6„ � 3 f I 1 1 1 2' I i I I 1 I / PBS 6 • .� ; - ° �.•' t- -- PBS .Al tt �� 7 i -t - i i 1 { __{- r I I 1 '� 3' - - {-------- STUB- -- - ---1-- T V --- ! -- f ! -- { -- - 1-- 1 UP & CAP F_- ------------- -- I -1--_-I-- --r- 7- -r- 6-1 6" 4 9L7 907 --- TO UNIT 2 05 ,r_ _ 100 101 300 129 SP -6 10 �� CONTROL PANEL a 2" 2 2" 1" 1112" 3° K 3' 1 l • 6" STUB UP & CAP FOR _ _ _ 200 201 301 904 907 90 1 _ FUTURE EXPANSION E ° 2" 2" 211 2" 1'/z" Y 1" TO FLP-1 - 1�7-- - - -- 6" TO FIRE & GAS SO 62� 302 200 1 -01 m 90 40 DETECTION PANEL _ 1" 2" 2' 2" t 1" 1" 300 302 303 100 101 SO 40 6„ 301 303 907 SP 129 10 6- 2" 2 QJV � � F� TO PBS -� FROM PBS � 1 1/2" i I 1 I I 1 1/2" 3„ 6" 6" 61 6„ I 6.. i 6" 3 1„ 3" 6 I " 6 1„I PBS 5 ', �- I 1 I I I� �1 /2,. -----� ---- ---- -- ------ 3" -_-- - -_ 300 100 904 (910, 906 905 10 `® 1 %z" 1 Yi' I6S, 6„ --_-^ 301 101 905 $ 00 100 101 90 70 2" 2„ 1 %z" 2„ 2„ 1 0 6„ J :' °� 302 200 906 301 200 201 w 70 ----- -- _j 2.. 2,. 1 /z" 2" 2" 2" a 1" L _ M p --_- -_ 303 201 907 302 904 907 90 •a 0 4 - 2„ 2„ 1 %z" 2„ 2„ 1 %z" 1 „ • .. 0 6„ - SO 129 903 303 129 SP • ° 1 %z" 1" 1 !"'2"\ 1" 1 " 1 %z" l I 1 1 i i 64. 1 1 i 1 t I I I 1 1/2" 3„ • - 1 •. I I . { I { — SEE DWf,. 1205.615 1 %z" 1 I I I ♦ I `Ij I 1 1 " TO FUEL GAS AREA SEE DWG. 120.35.611 TO PBS #8 .... ....._....�........,.....o..,.,o�..�.,� n DWG. CIIECKE -- - - - - - - --- -- ---- - -- STATUS BY DA REFERENCE DRAWINGS: 120.35.607 KEY ELECTRICAL ]NSTRUMENTI / PLOT PLAN - -- -- 120.35.618 PULL BOX STATION ASSEMBLY AND DETAILS PREL'Y -- 120.35.622 ELECTRICAL MISCELLANEOUS DETAILS - - - - - - - - - - - - - -- NOTES: BID 1. ALL CONDUIT EXITING THIS POINT SHALL BE TOTALLY 1 ISSUED FOR CONSTRUCTION DCM 11/1/93 CONSTR. - - - -- PVC COATED RGS CONDUIT. 0 ISSUED FOR BID KJH 9/03/93 - — -- -- -- - - -- PLOT DATE: -�- NO. REVISION - DESCRIPTION BY DATE CHK'D APP'D CADDS DWG. S221: — --"t--- TO IJB-3 APP_ RO' BY I DATE T 203561 903 906 E 5 70 6 10 1 " 3" 3" CDB-3 1 i 9 303 302 301 300 903 201 200 Tl1/z 2 2 2 1 907 906 905 904 90 1 %z" 1 %z" 1 %z" L19li�i! 303 129 SP 2 1 1Yz" ffiffi 907 1 %z° 301 220 201 300 100 101 6 90 10 2" 2„ 3 \ / 3„ CDB--5 90 100 1" 2' 904 101 2' 2' CDB-6 320 302 902 3) - 03� 40 3201 303 i P 10 3" CDB-8 301 300 2' 2' 40 323 322 967 CDB-9 300 2" j 2907 1 %i CDB-10 907 1 %z° 17 3' 1" CDB-11 ICU BY DATE _ S22138 P.L. OR STA. ACCGU,IT NUMBER 1994 coNSTRucnuN _ - _BY DATE Florida Gas Transmission Company Houston TEXAS PHASE III EXPANSION COMPRESSOR STATION N0. 20 ELECTRICAL CONDUIT DUCT BANK SECTIONS & DETAILS FT. PIERCE COUNTY, FLORIDA - -- - ---_- DESIGN DM 7/19/93 DRAWN KJH 08/07/93 'AS BUILT MFGRF W — FILE N AI FILE NO._ --- SCALE - - - _ NONE — - --- -- --- n303 301 2„ 2„ 32 2 b3o CDB-12 loll sldr,' prve S, to 90 V NIV E_RSAL_ P.O. %, 570240 F.d5C0 c. Nouaton.TeRm 77257-02+0 (7ls) sn mo ENRO f;AS PIPELINE CaRouP i DRAWING NUMBER 120.35.6192 OPERATING FLOOR REFERENCE_ DRAWINGS: 120.35.603 ONE LINE POWER DIAGRAM 120.35.604 ONE LINE POWER DIAGRAM 120.35.614 AUXILIARY BLDG. UNDERGROUND ELECTRICAL PLAN 120.35.605 ELEMENTARY nIAGRAM (TEMPERARY) 'FROM PORTABLE GENERATOR DISCONNECT TO BE REMOVED UPON INSTALLATION AND OPERATION OF MCC #2 SEE DWG. 120.35.614 FOR DEMOLITION 0 \ 5 S, EXISTING MCC 5 6 C3 DEC) Y Qp J U) Q J Q z U O �p U Q w n 3v� 30� Ijl0n �Fw0 U � n� Q n O U U� (I - Of I---dQ ��Q Yp 3uIn <-jcv Ez SPACE. m 0 J In z a AUX. BLDG. _J 0 0 =Q F- in -10< w Ln 10 KVA biwuln g� 0a - TRANSFORMER 0 24 CKT P E AUX. BLDG. 6 V LIGHTING Al IT/ T R KE PAN F I SPACE FRONT VIEW EXISTING MCC-1 7 YARD LIGHTING CONTACTOR SIZE 1 AIR COMPRESSOR STARTER 5 3" *AdH110 SWITCHRACK #II-1 FEEDER 225AT 400AF NEW MCC MCC #1 INCOMING BREAKER 400AT 600AF SPACE _.. __ _.... SPACE PHASE #4 FUTURE FEEDER SPACE SPACE SPACE SWITCHRACK #4 FEEDER 225AT 400AF SPACE MCC-2 AUTOMATIC TRANSFER SWITCH PANEL 800A El I TO PORTABLE GENERATOR DISCONNECT SEE DWG. 120.35.614 A B C D G I{ J K L M M� — DIRECT BURIED CABLES (3-500MCM, 1-1/0, USE-2) STUBBED UP IN 3" CONDUITS. SEE DWG. 120.35.615 Al ON Ln < r� r{y{yyy y Q{ v d },� 1811 rin, Cr�'w — 5.9e 400 UNIVERSAL P.C. k. 5IC240 _ _ENSCO,INC,ft,. n,'evw 7725)—CNB DWG. CHECKED _ APPROVED --- - =-1 STATUS BY DATE BY DATE BY DATE 522138 Florida Gas Transmission Company — ---- — ------ --- - - - P.L OR STA ACCOUM NUMBER Houston Texas 1994 —COI- PREL'Y PHASE III EXPANSION - -- — - -- - - ^ r,w� � s*, , _ DATE COMPRESSOR STATION NO. 20 --- ------ - _ DEscN DM 212/9- GROUP BID — — - DRAWN AS 2/2/93- SWITCHGEAR ELEVATIONS AND DETAILS 1 ISSUED FOR CONSTRUCTION dan 11/1/93 As BUILT CONSTRMICRFLM 0 ISSUED FOR BID AS 9/03/93 --- -_ _ 1_. _ M1I RELM - - - - -- - --- FT. PIERCE, FLORIDA PLOT_ DATE: _ ____ __FILE NO. DRAWING NUMBER NO. RFIVISION - DESCRIPTION BY DATE CHK'D APP'D CADDS DWG. S22138 2035620 scALE NONE 120.35.620//� FOR COWIN OF CONDUITS DWG. 120.3 . 314 i r r r r r r r„ r „r „� „r r r r r r r 8'. -_� -�_-� 2,. I 2„ I 4„ 4.. ! 4.. i 2 I 2 f 2 ! 2 I 4. 2„� 3 5.. I 5"5., I 5.. 5., ----- I I I I I I ! I I I I I I I ! I ! I I I I 1 I I --j I ! I I I I I I I I I I I I I I I I I I I •� I I I I I I I k ! t< I —4-— T I I f i I I I I f I I 11 I N I I ! I I I I I I I I ! I f I - -- — 01- 77-1 75 ---1 F 71 173 -- 31.2, 2A 2BI 1 — -- 74 76 1 1 1-------1..— —1--70 72 3 3/33 11/2 �/ -i - — -1 L—------ .. — — —� M (SECTION 3) (SECTION 2) ATS (SECTION 1) FRONT CONDUIT STUB —UP DETAILS FOR NEW MOTOR CONTROL CENTER "2 SCALE: NONE ._ �..n ,. . _.._. ...�......��....."..«�...,..�..-...,...n,..,...,_.'a,..,,.-,Y._..�-..'.«... ..... ..'...--,�. WORK ORDER NUMBER 13 { I, i, ---� t1". r o•'fi^u I :.'ads 7,�' �� r e 3 9 10 iRNISH BY AIR COMPRESSOR VENDOR AND I I MOUNTED BY r CONTRACTOR 13 171 aka fE-0299 15 23 1 1.. _ E145 .--- .--- E-QO03 TYP OF 2 E115_ TO OT NGIDE - I 1YP OF 1 LIG 12 17 1 14 1.! 16 E-0043 1" E-0 05 1%2 1" PVC SLEEVE29 E 25 E-0101 13 -r------E-0043 ( � s-- `�E-0065 T I I }] 5---�E-0045 10 AIR DRYER ��-TO COMP. BLDG. - TO FLOOD LIGHTS TO 120V RECEPTACLE SECTION " C-C" SWITCH RACK SCALE 3/4"=1'-O" 1" PVC SLEEVE E-0101 I SECTION "B-B" SWITCH RACK SCALE 3/4" -1'-0" FURNISH BY AIR COMPRESSOR VENDOR 10 18 5 14 11 o- - F, _ E:t_ 2 C- 3 - _ 6 7 I Is DuS DUCT 1 i i ( 1 1 10 URNISH 3Y AIR ;OMPI< /ENDC _ ,1 ry 1 3 I , j i f a. I � I � I � 1 I I I SECTION "A -A" SCALF 3 4"='-o_' 19 EQUIPMENT LIST UNIT FUNCTION DESCRIPTION NUMBER NAMEPLATE MARKING 1 400A DISCONNECT SWITCH 30, 480 V, 400A, DISCONNECT SWITCH NEMA 4 ENCLOSURE 2 J.W. HEATER 15KW, CONTACTOR SIZE 1, COMBINATION 480V, 30 H-565 60 CYCLE NEMA 4(DUPLEX) 3 J.W. HEATER CIRC. MOTOR STARTER SIZE 1, COMBINATION 480V, 30 PUMP 2 H.P. , P-565 60 CYCLE NEMA 4(DUPLEX) 4 LUBE OIL HEATER 26KW, CONTACTOR SIZE 2, COMBINATION 480V, 30 H-2020 60 CYCLE NEMA 4(DUPLEX) MOTOR STARTER SIZE 1, COMBINATION 480V, 30 _ 5 PRE/POST LUBE OIL PUMP P-2020 7.5 H.P. 60 CYCLE NEMA 4(DUPLEX) - 6 COMPRESSOR BLDG. 2 MOTOR STARTER SIZE 1, COMBINATION 480V, 30 VENT FAN VF-201 2H.P. 60 CYCLE NEMA 4 7 COMPRESSOR BLDG. 2 MOTOR STARTER SIZE 1, COMBINATION 480V, 30 VENT FAN VF-202 2H.P. 60 CYCLE NEMA 4 8 COMPRESSOR BLDG. 2 MOTOR STARTER SIZE 1, COMBINATION 480V, 30 VENT FAN VF-203 2H.P. 60 CYCLE NEMA 4 _ 9 WELDING RECEPTACLE CIRCUIT BREAKER NEMA 4, 30 CIRCUIT BREAKER C 480 V 30 A _ .1•�•:•:T _ •: P,IE# •:��M:PRE�5t�R•: �O::k+l':•:• :•:kt�t?�R::5:�',4ft?f�::512�•: RT:. ..:: .E............ ::I(BY A(R C;QpR 6;:V A1pQR... Sb.:.Y :3 •:;CO}CYG}E; AIEMA^:¢:......::__.:._• .... 11 _ COMPRESSOR BLDG. 2 24 CKT. LIGHTING PANEL, NEMA 4, 120/208V, 30,WITH LIGHTING PANEL 100A MAIN BREAKER, 1-3P,30A, 3-2P,20A AND 8-SP,20A BREAKERS 12 -_-- - -- - -- 30 KVA TRANSFORMER 30 KVA 480-120/2C8V, 30, 60 CYCLE 4-WIRE TRANSFORMER _ - 13 TRANSFORMER 40 AT T.M. BREAKER/ WITH NEMA 4 FEEDER BREAKER ENCLOSURE 30, 480 V 4 LIGHTING CONTACTOR CONTACTOR SIZE 1 208 30, 60 CYCLE, NEMA 4 WITH H 0 A SWITCH F HT 12 CIRCUIT LIGHTING PANEL, NEMA 4, 120/208V, 30, PANEL 4 WIRE, WITH 3 DP 20A AND 3 SP 20A BREAKERS 6 12'-0", 480V, 400A,30 BUSWAY W/GROUNDING BUS BUSWAY - 3R ---_ REMOTE PHOTOCELL CROUSE-HINDS CAT# DS-60 (MOUNT IN NORTH END OF BUSWAY) �8 COMPRESSOR BLDG. 2 MOTOR STARTER SIZE 0, COMBINATION 480V, 30 SUMP 1.5 H.P. , P-2022 60 CYCLE NEMA 4 18" X 12" NEMA 4 A 19 CONTROL J-BOX REFERENCE DRAWINGS:i.. 120.35,691 ELECTRICAL SWITCHRACK ASSEMBLY 120.35.604 ONE -LINE POWER DIAGRAM 120.35.605 ELEMENTARY DIAGRAMS 120.35.609 COOLER FAN AREA , 4567p_ 20.35.635 MISCELLANEOUS DETAILS SHT.#3 C Lf, -_i --- t 1-tom '811 oe�. - SOS .. UNIVERSAL_ P.0. q"570248 CN510, 'NC. Han1.1.T oa 99257-0249 O �T-Tr q) 977-7770 _ �L � ENR®,N GAS PIPEL6 1t'l, GROUP k DRAWING NUMBER 120.35.621 �'i I I 4 I 1 °- P'^e n t .) v.... :l i Oi l«AI`J^•a� 5T�T'G '�:Fn { T'""'I wt:. i J". J., 114 u""� .Ar i . P L, ._ _:..�v,. Y' ... ^,.•t . ......... a " : I I 1 I I c E-0692 " E-041 FLOODLIGHT DETAIL " 1" TYPICAL SKID MOUNTED EQUIPMENT GROUND CONNECTION N.T.S. HOUSE KEEL 4 m m O m #2/0 RUN - INSULATION (TYP-) N l N I 0 W E TYPICAL 0 -0422 .[. �{�.iY a •:Y ...x.. _ Y. z h^� •-r :."I rr . Y .. . ., . M . u.: _. . a 1 �tx i..yn?n��S: - a I I I I POLE """ SEE DWG. 108.35.618 FOR ----- E-0692 CONSTRUCTION DETAILS & HANDHOLE 108.35.635 FOR STUBUP ATTACH TO SERVIT #6 AWG THW INSUL. WIRE ASO GROUNDING BUSHINGS E-0413 "FOOTPRINTS' POST INSIDE POLE INSTALL PER NOTE #7 INSTALL PER NOTE #7 r - #6 CU. & DETAIL #13 GROUNDING BUSHINGS, PULL BOX- TYP.) THIS DWG, E-0693 E-0413 LOOP ALL GROUND WIRE FRAME �- T #2 GROUND WIRE ------ THRU BUSHINGS E-0422, E-0417 ° -T T �_ 1 1 • fit GRADE GRADE a III SCH. 40 PVC CONDUIT I I • .11 l 1" DIAM. E-0101 E-0101 GRADE • III I CIO E-0167 • I l i . _ _ #2 AWG INSUL. COPPER TO FLOODLIGHT ° ° GROUNG ROD CIRCUIT e� I I 1" SCH. 40 PVC CONDUIT CONDUIT & EL r \ EXTEND 1' MIN. CONCRETE—� •!_ __ __� FROM CONCRETE FLOODLIGHT E-0101 POLE FOUNDATION E-0110 E-0167 E-0101 —�- T1 PVC CONDUIT 1 E-0167 —ter' & 90' ELBOW JJ� E-0110--� l_ I� _- _1-- E-0101� E-0167� E-0101 E-04171 DETAIL"6" TYPICAL MCC GROUNDING CONNECTION N.T.S. ro GRADE BACKFILL TRENCH S AND COMPACT E "-. E--0422 0677 OR 0688 LSE FOR #2/0 END RUN E-0687 OR E-0678 INSULATE AFTER SPLICES ARE MADE - SEE NOTE 1 #2/0 RUN -THERMOWELD CONNECTOR #2/0 TO #2/0 USE E-0679 & E-0687 #2/0 TO #2 USE E-0680 & E-0685 TAP FAIL " AND N.T.S. m E-0292 --- I I I I S SI I I _ i I E-0112 T °I E-011 1 E-0122 1 rO l E-012 I T E-0002-�- ' E-0603 -- E-0207 E- 600- - , •> — E-Q112- E-0603--�1 s E-0(300� ' E 126 E- 006 E- 046 E-0692 I I. I E-0101 E0417 co z — �- — I --- �j • ° \\" =/ter _ _ —TO— GROUND \ L J _ ----------- - - - - GRID OR ROD L. 1 -01, i E-0167 MIN LEXTEND PVC CONDUIT #2/0, 1/C TO GROUND E-0167 BEYOND LIMITS OF DUCT E-01 10 BANK CONCRETE 1' MIN. GRID PVC COATED RGS 90' ELBOWS (TYP.) BUILDING COLUMN ATTACH TO FLANGE WHEN WEB SPACE IS LIMITED 1" PVC PIPE E-0101 - b COLUMN FOOTING E-0167 E-0110 E-0167 DETAIL 3 DETAIL "4' TYPICAL PULL BOX GROUNDING DETAIL TYPICAL BUILDING COLUMN GROUND N.T.S. N.T.S. NOTE: SPARE CONDUITS TO BE STUBBED OUT r L°� I C;'z E-0298 (TYP OF 4) -T r- S S I S S E-0112-- _I ) I I C l� E-0122� ° Lj _ J E_0002 E-0603—., _ — E-0600 E-01 12 -E--0600 E-0603 E-0601 E-0781 E-0002 (TYP. OF 4) E-0292 SEE DETAIL #13 THIS DWG. GROUND 1% POWER LEADS MOTOR CONNECTION BOX DRILL BOX AS REQUIRED AND INSTALL GROUND LUGS W/DURIUM BOLT, NUT AND WASHER. CONTROL STATION —� COMPRESSOR FRAME E-0693 1" PVC PIPE ENGINE FOUNDATION — E-0422-0� / E-0101 BUILDING COLUMN GRADE A-C 0 —� MINO� TO/GRO ND — - ------ ------ - — GRID E-0167 1" PVC CONDUIT---' E-0110 E-0101 E-0167 DETAIL "5" TYPICAL COMPRESSOR GROUND CONNECTION N.T.S. E-0234 E-0774 200A, 48OV, 30, FUSED DISCONNECT °� 200A, 480V, 30, 4 WIRE RECEPTACLE O C E-0692- #2, 1 /C = ° —_— --_- I� \/) SECURE GROUND E-0775 E-0216 JUMPER � WIRE TO PUMP FRAME. GRADE--,,,,,, GRADE 1" PVC .j....--- -- -- SCH. 40 PIPE FIN. GRADE DETAIL " 14° PORTABLE -TYPICAL GENERATOR RECEPTACLE I I �/ i��i� I I E-0417 — C � - N.T.S. E-0692 E-0101 f f �- ---------- -- -- ----- -`- --- E-0101 E-0680 GROUNDING NOTES E-0685 DETAIL "7" DETAIL "8" 1. ALL BELOW GRADE GROUND WIRE SPLICES OR TAPS SHALL BE MADE WITH SOLENOID RACK FOR GOV OPERATORS MOTOR CONNECTION GROUNDING CADWELD OR EQUAL PROCESS, SPLICES AND TAPS WILL BE INSULATED BY N.T.S. REFER TO 120.35.613 N.T.S. SCOTCH #2010 ADHESIVE PADS. 2. ALL EQUIPMENT SHALL BE GROUNDED WITH SERVIT POSTS OR OTHER INSTALL FLUSH WITH CAST CONCRETE COVER MECHANICAL CLAMPS OR FASTENERS AS NOTED ON DETAIL DRAWINGS. FINISHED GRADE f WITH HANDLE 3 GRO N W " _ GRADE E-0692 /�/I U D IRE SHALL BE RUN BELOW GRADE A MINIMUM OF 18 . THE GROUND WIRE, WHEN INSTALLED PARALLEL TO OR CROSSING A CONDUIT BANK SHALL NOT BE ENCASED IN PVC. 4. ALL GROUND WIRE SHALL BE 2/0 AWG STRANDED COPPER, WITH "GREEN" Lill � �{ THW INSULATION UNLESS NOTED OTHERWISE. 1 \ ' E-0693 5. REDUCED SIZE GROUND WIRE TAPS, WHERE NOTED, WILL BE #2 AWG EQUIPMENT FLAT SURFACE STRANDED COPPER WITH GREEN THIN INSULATION. r - -1 E-0700 (NUT NOT USED ON MOTORS 6. GROUND RODS SHALL BE 3/4" ZINC CLAD STEEL OR MAGNESIUM AND T I�l _L 1 1 - DRILL AND TAP.) BE A MINIMUM OF 10'-0" IN LENGTH. THE GROUND ROD SHALL BE 12" DIA. CONCRETE I E-0694 co INSTALLED TO A DEPTH THAT WILL PROVIDE A MAXIMUM RESISTANCE PIPE WITH BELLED BETWEEN EQUIPMENT AND GROUND OF 25 OHMS. SEE NOTE #7 7. SERVIT POSTS SHALL BE FIELD MOUNTED IN A MANNER THAT WILL INSURE END 1'8" LONG C GROUND ROD CONTINUOUS CONTACT WITH THE SURFACE IT IS MOUNTED TO. A HOLE THAT - - - WIRE CLAMP - IS 1/32" LARGER THAN THE SERVIT POST STUD WILL BE FIELD DRILLED (USE ONE CLAMP - THROUGH THE BOX OR FRAME. THE CONTACT SURFACE SHALL BE SANDED --- - COVER WITH INSULATING PASTE FOR EACH WIRE) TO BARE METAL AND THE SERVIT POST INSTALLED WITH THE APPROPRIATE R GOUND CABLE -- - -- - --- - SIZE NUT, LOCKWASHER AND FLAT WASHER. — #2/0 AWG INSUL E- 0427_ COPPER WIRE BURNDY SERVIT A r 3/4" X 10'-0" LONG POST -SIZE PER IX E-0695 TABLE GALVANIZED STEEL � GROUND ROD c ='g DETAIL " 12" DETAIL"13" a TYPICAL GROUND ROD TEST WELL CABLE TO E(�UIPMENT GROUNDING ° 1 N. m{ 9 y l VAA444��` NSCO, vc ( t 7-7 ))1S) OZ48 N.T.S. \� �� �� ,» . s„ DWG. CHECKED APPROVED WORK ORDER NUMBER -- — -- -- — — — -- _-- STATUS BY DATE BY DATE BY -DATE--- S22138 Florida Gas Transmission COrnpany - - -- - - _____.P.L. OR STA. ACCOUNT NUv.:,'. R -- - Houston, Texas ��V .fig ♦yx' GND WIRE BURNDY DRILL &TAP SIZE_ CAT. NO. SIZE 2 K2C25 3 8 -16 2 0 K2C28 _1 2 - 33 -- -- - --- ----- PREL'Y -- - - -- _ __ _ __ 1994 coNSTRucnow PHASE Ill EXPANSION yy � BY �rh J }i'g"; -r - - - ---- --- - ------ DESIGN COMPRESSOR STATION S N 20 NO DM . +� BID - — -- -- - KJH OS/OY AL ICDETAILS DRAWN AS i i/1/93 1 ISSUED FOR CONSTRUCTION CONSTR. „lr?i�, -- - As BUILT - MISCELLANEOUS #2 0 __- _._ ISSUED FOR BID DDK 9/03/93 PLOT DATE MicRFLM inrCRn-M -- FT. PIERCE, FLORIDA NO. — REVISION DESCRIPTION BY DATE CHK'D•APP'U cADDs —— -- - - DWG. S22138 2035622 FILE NO. sOA� _ _ NONE DRAWING NUMBER 120.35.622 " -'r ' E-0112 or UMk�, 5 DETECTORS E-1736 il 22 2) E-0602 12 2 ,,-E-0600 E-0630 BLDG. OPERATING FL 0 a N N m 0 M N E-02 18" K _L I I I I E-0163 I I E--0053 L E-0063 E-0101 ° 4 . 1 i i E-0123-7 E-01 13-7 / E-0359 E-0203 E-037 E-037C E-0112 S L _ _ _ J DETAIL #1 TYPICAL COOLING a. E-0003--� ; e E-0330 � E-0113 A E-0123 .p 18" MAX I I E-0043 I I I E-0101-/E-0163� TE-0163 ` E-0101 E-0063 E-0063 E--001 E-0013 DETAIL #4 GOV/HOV CONNECTIONS (TYP.) PIPE SUPPORT ,1— GRADE tall Bmhq )1w. — S�itc P.O. 8c. 5)C218 M1ou,ton,?exo, 77252-0248 (713) 971-7710 ,S Vailtl9kp.sMi DRAWING NUPOFIR 120.35.624 I 7WIM ?' I 1 I, r 4. .. 1 .. 1 E I L I I I I I i t I I I I+, a r L I 1. a I i I I II 1 i 1 I , I , I IJB-3 TR_1 TM -I) _PT-201 A STATION SUCTIO PT201A PT, (BK) *(Wi NOTE: 1. CABLE `. 2. CABLE CONTINL r H �n h {y Ac S r FIREi GAS DETECTIN BO (IN COMP. BLDG.) r TO DWG. 120.35.637 JB-1 JB-2 JB-3 - --- - -- — — --- -------------- 99R + TB-1 SE-2084(+ RTB-1 TB-1 TE-2082 R __- TE-2081 R TB-2 99R - i I 2 1 ISE-2084� TE-2080-1 (-) TE-2080-6 (-) TB-2R ) TB, 3 TE-2085-3A (-) _ 26AML R 1 -- �— Z1 1 1 26AMR(R) 3 TE 2081 B� 26HL1(-) - 1 I I TE-2080-1 (+) TE-2080-6 (+) 1 1} (-) 26HR3 26A3 (- TE-2085-3A (+) 3 TE-2082 B - 26HL1(+) 2 — 2 I�� (+) 26HR3 26A3 (+) 2 TE-2085-4B-O 26AML W 2 - 2 - 26AMR(W) 99A + SE-2082 + TE_-2080-3 (-) TE-208_0-8_(-) TE-2082 W TE-2081 W -"- 4 26HL2(-) _R_ 3 TE-2080-3 (+) TE-2080-8 (+)_.I 3 (-) 26HR4 26F4 (-) 3 1 1 TE--2085-46 (+) 26AML(W) --- 26AMR(W) JB-3L -- 99A - -5 ISE-2082 - 26HL2(+) 4 ----- 4 (+) 26HR4 26F4 (+) 4 TE-563 R TE-2011(R) -- 6 T_E-2080-5 _ (-) TE-2080-10 (-) 5 (-) 26HR5 26A4 (-) 5 �TE-2085-4A (-) 261W0 R 5 --� 5 26Q0 R 99E � SE + 26HL3(-) 5 TE-2080-5 (+) TE-2080-10 (+) 1 W W - I I TE-2085-4A (+) TE-_563 B TE-2011 B 1 1- O -( 7 6 26Q0 W 99E - 1I - SE-2081 - W 6 (+) 26HR5 26A4 (+) 6 -- 26JW0 W 6 TE-563 W TE-2011 W I O I --� 8 26HL3(+) R 6 TE-2080-7 (-)__ 7 (-) SP 26F5 (-) 7 b-TE-2085 5B (-) _ 26JWO(W) 7 7 26Q0(W) TB-1 26HL4(-) - 7 _ TIE-2085 5B (+) -8 99TL(+) 99TL(+) - 99G + 9 SE- 12083 + T_E-2080-7 (+) 8 (+) SP 26F5 (+) W 8 _ 8 26HL4(+) 8 ---- TE - 5A (-) VE-2382 C WH1 WH5 VJY-2089 C 99TL(-)1 99TL(-) 10 9 (-) 26F1 26A5 (-) 9 ( ) 9 39NL C - 2 -- 99G SE-2083 - R TE-2080-9 _ (-)_- TE-2085-1_B (-) _ R R - - - ---- 39EV1 C i 1 g i i VE-2082 - WH2 WH6 VJY-2089_(- I i 11 ( ) - 11 26HL5(-) W 9 TE-2080-9 (+) TE-2085-1 B (+) _i W TE-2.085-5A (+) -- 10 (+) 26F1 26A5 (+) 10 - — — 39EV1(-24) 10 } VE-2082 + BK2 BK6 VJY-2089 + X �0 39NL(-24) 3 12 26HL5(+) 10 - TE-2085-1A (-) TE-2085-6B (-) O I 11 39NL +24 991 + - SE-2086(+� SP - 11 - 1 1 (-) 26A1 26F6 (-) 11 I 1 TE-2085-6B (+) 39EV1(+24) I I 1 1 I I VE-2082 S BK1 ` BK5 VJY-2089(S�_I ( ) - 13 SP(+) 12 TE-2085-1A (+) I I 39EV1 S1G 12 - 12 39NL(S1G) 991 - I 14 1 ISE-2086 - r12 (+) 26A1 26F6 (+) 12 - ( ) _________TE-2080-2 (-) TE-2085-26 (-) B TE=2085-6A (-) 13 13 ---- - -- 26HR1 ) 13 1 I TE-2080-2 _(+) TE-2085-2B (+) I (-) 26F2 26A6 (-) 13 I TE-_2_085-6A (+) VE-2081 C WH3 WH7 VJY=2088 (+) 26F2 26A6 (+) 14 - 39EV2(C) 14 14 39NR C) 99TL + 6SE-2089(+) 26HR1+) 14 VE-2081_ - WH4 WH8_VJY-2088 - �_085-7B (-) _ -� 15 39NR 24 9TL i ISE-2089`TE-2080-4 (-) TE-20852A (-) R (-) 26A2 26F7 (-) 15 --- 39EV2(-24) 15 _ )26HR2(-) W151 TE-2080-4 (+) TE-2085-2A (+) 1 1 TE-2_085-76 (+_) x VE-20 S BK4 BK8 VJY 2088 +W 39EV2 +24 16 16 - 39NR(+24) 26HR2(+) 16 — TE-2085-36 (-) (+) 26A2 26F7 (+) 16 39Ey2 SIG) j 7 VE_-2081 S BK3 BK7 VJY-2088 S ()��__ -��—K3-��17 39NR SIG 99TR +SP(-) 17 - - (-) 26F3 26A7 (-) 17 TE-2085-7A (+)(+) I I ( ) 18 99TR - 1 I 19 i ISE-2088 - JB-3R - yy TE-2085-36 (+) 1 18 (+) 26F3 26A7 (+) 18 --- 18 TE-2019 R TE-2001 R 20 SP(+) 18-� 19 26QTD R 26TEI - 19 � TE-2080-13 (-) 19 (-) SP SID (-) -B 19 26PLO(R) - 19 ( ) TE-2080-13 (+) 26PL0 W II 20 IITE-2019(B) TE-2001 B II 20 1126QTD(W) SEE NOTE 1 21 SEE NOTE 1 --<7 26TEI(+) 20 20 (+) Sp SP (+) 20 ( ) - TE-2019 W _ TEE=2001 W i 26TEOL(-) B 21 �- TE-2080-15 (-) TE-2080-14 (-) 21 (-) 26TEOR Sp (-) 21 26PLO(W) 21 21 26QTD(W) 26TEOL(+) 22 1 1 TE-2080-15 (+) TE-2080-14 (+) 22 (+) 26TEOR SP (+) 22 22 22 COIL &TAPE �� - SP - 23 COIL & TAPE -23 - SP SPARE COIL & TAPE 24 SPARES 24wt SPARES -__ — JB-4 63JW(C) - 1 PSLL-566 63JW(N.O.) - 63TOP(C) - 2 3 PSHH 2O88 _ PSHH 2O88 63TOP(N.O.) - 12E(C) - 4 5 PSLL 2081 12E(N.O.) - 6_ PSLL _2081 -- - 26EB(C) -- 7 PSLL 2085 PSLL 2085 26EB(N.O.) - 38TBFL(C) - g —� - PSLL-2084-1 P_SLL_2084 1 38TBFL(N.O.) -- _g 10 38TBFR(C) - 38TBFR(N.O.) - -11- 12 ---PSLL 63C(C) - 13 - _PHSHH-2O26044 PSH 63C(N.O.) - 39FV(C) 14 - 15 PSLL 2086 - -__ _ 39FV(N.O.) -- 16 2086 -_ ---PSLL PSLL-2078 39POT(C) 39POT(N.O.)-PSLL_ 1 - - - — - 2078-_--___f 39CRD(C) - TB-4 PSLL-2083_ _ 39CRD (N.O.) 12E (C) 3 12E(N.O.) -- 4_ 26EB(C) 5_ 26EB (N.O.) 6 38TBFL(C) -- 7 38TBFL (N.O.) - _8 38TBFR (C) - 9__ 38TBFR(N.O.) -- 10 63C (C) _1 1 63C(N.O.)- 12_ 39FV(C) - 13 39FV(N.O.) 14 39POT(C)- 15 39POT(N.O.) - 16_ 39CRD(C)-- 17. 39CRD (N.O.) -�18 COIL & TAPE SPARES TB-1 1 63JW 63JW - 63TOP _2 3 PSLL-2017 4 63 TOP 6--- 6 630E - 630E PSLL-2017 63QE 7 63QE 8 9 SP 10 TSHH-563 - 26JW 26JW 11 _ L- TSHH-563 ----- 12 13 14 260E 260E _TSHH-2011 TSHH-2011 PSLL-2001 - 63QT 63QT 39QMP 39QMP 15 16 _ PSLL-2001 AE _2012 17 18 _ AE2012 - -- — TB-2 1 26JW 2 26JW 3 26QE 4 260E 5 63QT 6 63QT 7 SP 8 - 9 SP 1_0 1 1 - SP � 3 LSLL_2004 -- - 71 CL/CH _ LSI_L-2004 -14 71 CL/CH YS 2002 15 - 80LFE --- YS-2002 - 80LFE ----- 16 YS_ 2003 - - 17 SOLFC YS 2003 ----- - - -- 80LFC 18 NOTES 1. WIRING & CONDUIT FURNISHED WITH ENGINE & INSTALLED BY CONTRACTOR JB-12 — - - ---- - J811-TBl -6 . IGNITION RELAY-"-- AlX YZ 2088-6-3_ YZ--2086--1 -- --- --- - --- AtY YZ-2086-3 OFU (+) TB-1 +DC POWER K2 (+) (-j K1 A4Y {_3AL(_j DC RETURN ____ -.. - - -- 5NIGN(-) 3 YZ-2086-1(-2 TO ALTERNATE MODULE -.__ 520IGN(+) Y__ 2086_-1(+) 1 LEGEND SHIELD NOT CONNECTED AT THIS END JB=11 TB-1 JB9-T133-A 2 JB9-TB3-B 3 4 J I:5 I 4 - L_ 1 ISSUED FOR CONSTRUCTION 0 ISSUED FOR BID NO. REVISION - DESCRIPTION 119111111 16 SH 1196 III -8PR #16 SH ----JB-9 COIL & TAPE CPU 11 SPARES JB11 -TB 1-1 TB-3 JB11-TB1-3 �A B IGNITION MODULE COIL & TAPE TB-1 SPARES 12 YZ-2086-2 C f FAULT 1 1 --- - - 545LIGN l YZ-2U86-2 N.0 OUT - 10- �- 9 _8 7 503 ARID AUTO RETARD j 6- 11 (503 ARTD)___ (1 STEP) ` 4- DC _RETURN_ _ 3- _,—+ _ DC POWER_-_T 596IT(+) 5961T(-) - 1 596IT(-) CONTRACTOR TO ADD - -- DWG. STATUS uritulctu ------- BY ---- DATE -- --- -- --- —_ PREL'Y BID - ---- --- — -- -- AS 11/1/93 -- C'DHK _ APP'D CONSTR. --- - AS BY 9/03/93 DATE -- - CADDS PLOT DATE: _ DWG.. _S22' 1 1115A1 8PR #16 SH I TO LEFT BANK COILS SEE NOTE 1 TB-1 1 2 3 4 5 -6_ _T N SS - SEE NOTE 1 J J B_ 10 61C 1 UN (ON TO RIGHT BANK COILS - T COIL & TAPE SPARES 40OVDC IGNITION VOLTAGE PULSE (600V INSULAIION) P2- 120A 30/C #14 ------------- _ ® TO DWG. 120.35.637 - �- 1-0 DWG. 120.35.636 A �g970� -_ --® R a \ Ca' 1 9T O 1611 u�Np - SOI, -.o UNIV ER_ -AI_ P.O. Po. 510248 ersco, u+c. H... ... 7 257-0248 qq a 77-7 QED WORK ORDER NUMBER_._ Florida Gas Transmission Company -- BY S2.2_13.8 _DATE_ _ P.E OR STA. ACCOUNT NUMBER I-IOUSton, Texas 1994 coNSTRucnoN PHASE III EXPANSION : A , j ��� BY DATE DESIGN GB $ 7�3 COMPRESSOR STATION NO. 20 GROU -- DRAWN DDK 8/7L93 ELECTRICAL '_,•..�� � AS BUILT — _ COMPRESSOR INTERCONNECT DIAGRAM, sht 1 MICRFLM -- ----- FILE NO. --- scaLE NONE FT. PIERCE, FLORIDA ._—__.._-_____--_—. DRAWING NUMBER � 120.35.629 / I I (-R) - COMPR. 526CS5 (W)1- CYL. 3 W - SUCTION TEMP. SHIELD COMPR. 526CD4 CYL 4 DISCHARGE TEMP. COMPR. `� S26CS4 CYL. 4 SUCTION --- TEMP. 1 18 Lo J TE 503-3(l)) TE 503-3 TE 50 ' - TE 511 ---- T E 5 _ TE xL., SHIELD_J SHIELD COMPR. CYL. 3 VIBRATION (39C3) n VE-2085- SIGNAL 1 V VE-2085- ---- V+ v_ 2 3 — I I I VE-2085- VE-2085- COMMON 4 V -J --� SHIELD 0 SIGNAL 1 n VE-2085-1 8K1 COMPR. -. VE 2085-1 BKZ- CYL. 1 V+ 2 �-- --5-- VIBRATION V- 3 11 VE-2085-1 WT2 (39C1) COMMONi4 V VE-2085-1 WT1 SHIELD - ) �11781 1TF TE::503-4 R TE-503-4 Vv TE-503-4(B 112413I2PR #16SH SIGNAL 1 n VE-2085-2 BK1 I COMPR. -- V+ 2 2 VE-2_085-2 BK2 CYL 2 11 VE-2085-2 WT2 VIBRATION V_ 3 (39C2) -- VE-2085-2 WT1 COMMON 4 U -- SHE LD-J (124D 2PR 16SI1] SIGNAL 1 n VE 2085-4 BK1 I. COMPR. - V+ _2 EVE-2085-4(BK2) CYL 4 _ _ -- - I I VE-2085-4 WT2 VIBRATION V- 3 (39C4) COON 4 VE-2085-4 WT1 CO - SHIELD -�-� 'W COOLER FAN B /IBRATION SWITCH 3HH-561 B (539AFV) 'W COOLER FAN A ✓IBRATION SWITCH SHH-561A (539AFV) COMPR. 526CD1 CYL. 1 DISCHARGE TEMP. COMPR (� CYL. 1 SUCTION TEMP. COMPR CYL DISCHARGE TEMP COMPR CYL SUCTIOt TEMP 05B 1PR 16SH 05F 1PR 16SH VSHH561(± NC VSHH561A BK C VSHH561 (WT) VSHH561 (WT) ] -x NO NC C NO tall 13mn9 0.be — S.A. 200 P.O. 8- 570243 Houston imu 71257-0248 (713) 97 1-7710 COOLER A/W CONTROL (+)-_#LITY VALVE A I/P (-) TY-569A -- - ----__.--- TY569 (LOCATED ON TCV-569A) 'X A/W -- _ - TY569B + BK HYDRAULIC+� --- TY569 + WT CONTROLLER (-) NOTE: TY-569B 1 x 24VDC SUPPLIED FROM (LOCATED ON TCV-569B) UNIT CONTROL - -- - PANEL J/W COOLLR NC VSHH560 + BK FAN C VSHH560 WT ��j VIBRATION x SWITCH NO -- VSHH-560 NC (539JFV) --C - NO --- J/W CONTROL TY566B VALVE I/P (+)_ _ 1-Y TY---5668 (-) 5668 SHIELD (LOCATED ON J/W COOLER) UNIT FUEL GAS STATIC PRESSURE SHIELD PT-2053 UNIT L-- FUEL GAS DIFFERENTIAL PRESSURE DPdT-2053- FROM EXIST. CONTROL BL 124A 2PR 16SH 124B 2PR 16SH 124C 2PR 16SH 124D 2PR 16SH PT2053 (BK PT2053 (WT �25A 1PR 16SH1PR 16SH PdT2053 BK PdT2053 (WT) l 1125AI 1PR #16SH 125E 1PR 16SH 125C 1TR1 16SH I SHIELD I R -- - - W UNIT W FUEL GA! TEMP. T -20 3 116A PR #16SH 116B 1PR #16SH 129A 11PR 16SH 129C 1PR 16SH 110A 1PR #16SId 110E 17' 16SH 110C 1PR 16SH 110D 1PR 16SH TO DWG. 120.35.636 FHASt III LX[JANSION BY DATE DESIGNCOMPRESSOR STATION NO. 20 g t p ... DL... 9 tf93_ - -- -- DRAWN DDK_ /3193 COMPRESSOR INTERCONNECT -- - ,�AS BUILT- - -- DIAGRAM SHT. 2 MICRFLM - -_ - - MICRFLA - ---- FT. PIERCE, FLORIDA ...FILE NO.- DRAWING NUk4KR 5628 SCALE NONE -- — 120.35.630 , T o CONMA-1- (,Nz CAL31-J.- SCHEDULE CONDUIT CONDUCTORS CONDUIT CONDUCTORS TAG TAG FRA IFROM TO FOR LENGTH REMARKS FROM NO. SIZE No. SIZE TYPE VOLT NO. 0. SIZE TYPE VOLT LENGTH TO 1 4/0 1A ELECTRICAL UTILITY CO. POLE SERVICE SWITCH RACK FACILITY INCOMING POWER USE-2/CU 600VAC DIRECT BURIED 3 500 MCM ------ 101 UNIT PANEL IPBS-6 LSHH-2050,PSL-2050 FIR 16 SHLD PVC 600VAC SIZE TYPE 1 4/0 _ T�HLDPVPC 1B F! 17�TRICAL UTILITY CO. POLE SERVICE SWITCH RACK FACILITY INCOMING POWER USE-2/CU 600VAC 104 DIRECT BURIED 3 500 MCM 4 0 1 'HRACK MOTOR CONTROL CENTER #2 ATS MOTOR CONTROL CENTER FEEDER USE-2/CU 600VAC DIRECT BURIED 105 UNIT PANEL 3 500 MCM PR 16 SHLD PVC 600VAC SERVICE SWITCHRACK MOTOR CONTROL CENTER #2 ATS MOTOR CONTROL CENTER FEEDER 1 4/0 USE-2/CU 600VAC DIRECT BURIED 106 3 500 MCM 1 2 ATOR CKT. BRKR. TRANSFER SWITCH, MCC #2 EMERGENCY POWER FEEDER 3" XHHW-2/CU 600VAC RUN NEW CONDUIT 107 3 35.0_MCM___ 1 2 77-57PT-514 FIR #16 SHILD PVC 600VAC EMERGENCY GENL��ATOR CKT. BRKR. TRANSFER SWITCH, MCC #2 EMERGENCY POWER FEEDER 3" XHHW-2/CU 600VAC RUN NEW CONDUTI 108 3 350 MCM1PR 16 SHLD UNIT PANEL CONTROL RACK E PVC 600VAC 1 4 MOTOR CONTROL CENTER #2 ATS EMERGENCY GENERATOR CONTROLS 1 1/2" 12 #14 THWN/CU 600VAC RUN NEW CONDU11 109 1 #1/0 5 MOTOR CONTROL CENTER #2 EXISTING MCC FEEDER PSLL-2073,L 560,1 XHHW/CU 600VAC 110 — — ---- 3" 3 250 MCM UNIT PANEL PSLL-2017 6 MOTOR CONTROL CENTER #2 NEW SWITCHRACK #4 SWITCH RACK FEEDER 1 #1/0 3" XHHW/CU 600VAC ill 3 250 MCM UNIT PANEL J1310 FIR #16 SHL D PVC 600VAC 1/0 7 MOTOR CONTROL CENTER #2 EXISTING PULL BOX 11-1 EXISTING SWITCHRACK 11-1 1 3" 25 MOM XHHW/CU 600VAC 112 TO EXISTING PB UNIT PANEL JB9 3 PR #16 SHLD PVC 600VAC PORTABLE GENERATOR 1 #4 8 MOTOR CONTROL CENTER #2 ATS RECEPTACLE 200A PORTABLE GENERATOR 2" HW/CU 600VAC 113 6PR _3 j UNIT PANEL T/C TO POWER _& XH PORTABLE GENERATOR C #16 SHLD PVC 600VAC 9 EXIST. MOTOR CONTROL CENTER #1 RECEPTACLE 200A PORTABLE GENERATOR 1 #4 REMOVE AFTER i 2" XHHW/CU 600VAC 114 3 3 0 UNIT PANEL JB12 600VAC MCC__J_N_ _P LAC E_ 16 SHLD PVC 10 MOTOR CONTROL CENTER #2 STUBBED OUT OF PULL BOX #8 FUTURE SWITCHRACK 3" 115 UNIT PANEL JB3 --- 1/27 16 SHLD PVC IROMIA(' SWITCHRACK #4 COMPRESSOR BLDG. UNIT PANEL PUMP, HEATER & FAN CONTROL �2 #14 TC/PVC 600VAC 116 UNIf PANEL LSLL- 61 7IIS r 1 16 SHLD PVC _ 12 LIGHTING PANEL ®SWITCHRACK #4 COMPRESSOR BUILDING INSIDE LIGHTING 7 #12 THWN/CU 600VAC 117 UNIT PANE:- COMPRESSOR CYLINDER RTD 16 SHLD PVC 600VAC ►, 13 LIGHTING PANEL @ SWITCHRACK #4 COMPRESSOR BUILDING INSTRUMENT AIR DRYER M-2030 3 #10 THWN/CU 600VAC 118 UNIT PANE' 7- COMPRESSOR CYLINDER RTD'S #16 SHLD PVC 600VAC 14 LIGHTING PANEL 0 SWITCHRACK #4 COMPRESSOR BUILDING RECEPTACLE FEEDERS THWN/CU 600VAC 16 SHLD PVC 600VAC 1" 7 #12 119 UNIT PANEL FLOOD LIGHT CONTACTOR 15 — --- -- @ SWITCHRACK #4 COMPRESSOR BLDG. VIA CONDUIT 14 OUTSIDE LIGHTING 1 3 #12 THWN/CU 600VAC 120 UNIT PANEL JB - #14 PVC 600VAC 480V 30 MOTOR FEEDER 3 16 SWITCHRACK #4 AIR COMPRESSOR & CONTROL 1 1/2" 1 16 THWN/CU 600VAC 121 TT-2052 & FE-2052 FUEL GAS AR 14 1 16 SHLD FLOOD LIGHT CONTACTOR — ----- PVC 600VAC 0 SWITCHRACK #4 17 FL-1 FLP-1 BRANCH CIRCUIT ill #10 THWN/CU 600VAC ROUTE TO PBS-9 124 3 UNIT PANEL COMPRESSOR CYLINDER VIBRATION 16 SHLD PV 600VAC 19 SWITCHRACK # 4 J.W. HEATER 15KW H-565 J.W. HEATER FEEDER IINTERLOCK w7 4 #10 THWN/CU 600VAC --- :CIRC. PUMP 125 UNIT PANE UNIT FU, ETERING COMP. BLDG, 6 SHLD I P C J.W. HEATER CIRC PUMP 600VA 20 SWITCHRACK # 4 480V 30 MOTOR FEEDER 1 4 12 THWN/CU 600VAC 2HP P-565 & CONTROL, HEATER CONTROL 1:�9/c 14 21 INTERLOCK T'T SWITCHRACK # 4 LUBE OIL HEATER 26KW H-2020 LUBE OIL HEATER FEEDER 1 10 THWN/CU 600VAC PUMP P-820 127 UNIT PANEL -2017,T -2083 600VAC ----- - -- --1-3C 14 TE-566BJE 6 SHLD PVC PRE/POST LUBE OIL PUMP 480V 30 MOTOR FEEDER 4 #12 EXIST. STATION FUEL MET THWN/CU 600VAC 128 EXISTING DANIEL FLOW COMPUTER IN NEW LOCATION 22 SWITCHRACK # 4 7.5HP P-2020 & CONTROL,_HEATER CONTROL 9/c - --I--__ 16 SHLD PVC 600VAC 480V 30 MOTOR FEEDER 1 23 SWITCHRACK # 4 1 HP SUMP PUMP P-701 4 12 EXIST. STATION CONTROL PANEL . ... ... THWN/CU 600VAC 129 FUEL GAS AREA LSHH-2050, PSI_-2050 TR __v9/C 11, 4 IN EXISTING COMPRESSOR BUILDING _QL 16 SHLD PVC 600VAC 480V .30 MOTOR FEEDER 24 SWITCHRACK # 4 VENT FAN VF-201 2HP &PSH-514A 4 #12 CONTROL 1-9/C THWN/CU 600VAC 130 UNIT PANEL COV--2059 FUTURE AUTOMATION 14 • 2 SPARES 131 25 SWITCHRACK # 4 VENT FAN VF-202 2HP 480V 30 MOTOR FEEDER 1' 1 4 12 THWN/CU 600VAC 3 132 26 SWITCHRACK 4 4 30KVA 480/120/208 TRANSFORMER TPAKIQf700kAFD C'C7[7nC-D 4 12 1 3 14 1 mvv"4/uu 600VAC 200 CONTROL ROOM PBS-6 SPARE 2" 26A 30KVA 480/120/208 TRANSFORMER COMP. BLDG. #2 LIGHTING PANEL LIGHTING PANEL FEEDER 1 1 1/2" 4 2 1 ON SWITCHRACKJ_4_______ ------ ONSWITCHRACK #4 THWN/CU 600VAC 201 CONTROL ROOM PBS-6 SPARE 2" 27 SWITCHRACK # 4 30A, 48OV, 30, WELDING RECPT. WELDING RECPT. FEEDER 1 4 #10 THWN/CU 600VAC 300 CONTROL ROOM IJB-3 ANALOG & DIGITAL CONTROL 2" 1-24PR 600VAC 1 PR #16 SHLD TO 28 SWITCHRACK # 4 VENT FAN VF-203 2HP 480V 30 MOTOR FEEDER 1. 1 4 112 C - 0 - NTROL C 14 THWN/CU 600VAC 301 CONTROL ROOM IJB-3 SPARE 2' 29 SWITCHRACK # 4 COMPRESSOR BLDG. SPARE 302 CONTROL ROOM IJB-3 SPARE 2" 40 PBS-6 PBS-9 SPARE 303 CONTROL ROOM ------- IJB-3 SPARE 2" 41 304 70 MOTOR CONTROL CENTER #2 CONTROL ROOM (ESD-2 PANEL) 120VAC UPS POWER FOR MCC 1-9/C #14 TO 600VAC 306 -SHUN.T-Tpdp-. BREAKERS IJB-3 MAIN LINE VALVE AREA PT- 201A PT-201B 7523 ill 3 FIR #16 SHLD PVC 600VAC 71 MOTOR CONTROL CENTER #2 PBS-2 SPARE — --- --- STUB OUT & CAP 307 IJB-3 GAS SCRUBBER_ AREA I-SHH-2003B 1 1 PR #16 SHL C PVC 600VAC 72 MOTOR CONTROL CENTER #2 PBS-2 SPARE 1 1/2" STUB OUT & CAP 900 73 MOTOR CONTROL CENTER #2 PBS-2 SPARE 2" STUB OUT & CAP 901 74 MOTOR CONTROL CENTER #2 PBS-2 SPARE STUR OUT & CAP 902 75 ry -------- MOTOR CONTROL CENTER #2 PBS-2 SPARE 511213m; WIS 600VAC INSULATION IS REQUIRED EXISTING CONDUIT 2EROUTED-NEW CABLE NO WIRE PHASE III FUTURE FUTURE FUTURE FUTURE FUTURE ------ STUB OUT & CAP 903 AUXILIARY BUILDING (FIRE & GAS J-BOX) CONTROL ROOM (FT-100C) SPARE 1 1/2" 1z, FUTURE 76 MOTOR CONTROL CENTER #2 PBS-2 SPARE 1 1/2" 904 COMPRESSOR BUILDING CONTROL ROOM (FT-100C) FIRE & GAS DETECTION 2" 4 TRI STUB OUT & CAP 8 PR #16 SHL C TIC 606kc 77 MOTOR CONTROL CENTER #2 PBS-2 SPARE 2 905 AUXILIARY BUILDING (FIRE & GAS J-BOX) CONTROL ROOM (FT-100C) 1 1 /z, 3 TRI SPARE FIRE & GAS DETECTION 4 TRI 16 SHL TC 90 CONTROL ROOM UPS DIST. PANEL COMPRESSOR BUILDING IUPS POWER FOR EMERG. LIGHTING 1" 3 #10 TO 600VAC 906 CONTROL ROOM AUX. BLDG. MCC ATS CONTROL & SHUNT TRIP 1 1/2" 1-20/C #14 THWN/CU 600VAC T 1010CONTROL ROOM FT-T-100CUNIT PANEL 2- 600VAC 6 SHL — ----- 1-2PR116 SHL TC 907 CONTROL ROOM (FT-100C) —SWITCHRACK #4 VENT FAN CONTROL 1 1/2" 8 PR #16 SHLD TO 600VAC RG62 I COAX ) 1 :2 > NOTE: DWG. C - HECKED,__ APPROVED WORK O_R6F_F�_Nj�MBER STATUS DATE _-BY —DATE 6Y_ DATE S22138 Florida Gas Transmission Company - XHHW-2 INSULATION DRY WET RL OR STIC A&1556NT NuuBER LOCATIONS @ 90* Houston, Texas 1994 CONSTRUCTION ENRINNI INDICATES VOLTAGE RATING OF THE CONDUCTOR PREL'Y PHASE Ill EXPANSION BY DATE AND NOT THE SYSTEM VOLTAGE. GAS PIPELINE BID DESV4 COMPRESSOR STATION NO. 20 UROUP DM V21/93 —of?AwN AS 4/21/93 CONDUIT AND CABLE SCHEDULE 1811 8�1�11 0��. - SvI. 400 ISSUED FOR CONSTRUCTION JCT 11/1/9 1 AS BUILT JNPVERSAL_ P 0, 00X 57024a Avv_�4____ z ENSCO. INC. 77257 02.8 CONSTR. (713) 977 7770 0 ISSUED FOR BID DDK 9103 MICRFLM _j FT. PIERCE, FLORIDA FILd DATE: NO. REVISION DESCRIPTION BY DATECHK'D APP'D CADDS DWG. n1_E1_N10_ DRAWING NUMBE:R AS2213��L2035632 scALE NONE 120.35.6,32 T _.,a. ,.. P v"_ P 3s .,... . " r n.. . .m 'r'F_. '+ ,. y.:F vt'... At4 e. r., . :ROE.. .,» rv",,.. Iv:X' 1 .:; 5.. b 9 'i R; I i= I PULL BOX \\ \\ \ \ GOV 3 120.35.641201 \ \ SVO \\ \\ \ \ / 201 \ \ \\ SVC \ ` PT \ 201 \ / �� A i 6 120.35.641 201A ZSO NOTES: 1. VALVE OPERATORS HAVE BEEN PURCHA ED FULLY EQUIPPED FOR FUTURE CONNECONS NOT BY PHASE III CONTRACTOR. PdS 201 16 SH 201 Zsc 0 201 \ NOTE 1 C 1 1 / \ GOV 2 SVO 120.35.641 \\ 7 520 — \ 520 I SVC < 520 ZSO 520 ZSC — 306C 1PR 16 SH 520 � NOTE , / 512—.G4. I DWG. PREL'Y 1 CHECKED APPROVED BY T DATE BY DATE T BY J DATE — — — — BID-- 1 ISSUED FOR CONSTRUCTION RLS 11/1/93 _ CONSTR. -- — — — ISSUED D— AS 9/3/9D { N0. IISIONFOR V REVISION DESCRIPTION BY TC3CHK'DIAPP'D — CADDS � PLOT DATE DWG. �S22136�F\2035634 S22138 P.L. OR STA. ACCOUNT NUMBER CONSTRUCTION BY _ DATE DESIGN CH 819193 DRAWN JCT 8�9L93 AS BUILT MICRFL)A _FILE NO. SCALE -- Kim, 11 3/4' C, -- 306A 1PR �15 SH 1,306131 1PR #16 16 SH 306 306A 1PR 15 " 306B 1PR 16 . T 1�. 306C 1 PR 16 S' I N.T.S. Florida Gas Transmission Company Houston. Texas PHASE III EXPANSION COMPRESSOR STATION NO. 20 ELECTRICAL/INSTkUMENTATION 30 DISCHARGE VALVE AREA FT. PIERCE, FLORIDA M 1511 BERING LRlp — SUP, 4'O P.O. BO% 57N4 HQ STCk.,-KA 171J7'C218 a s1c%' I ^14 DRAWING NI,I�fR120.35.634 z u.• sr aou 3a, .0 t. x +24VDC P8 -24VDC P7 D m m O c� = W H ofo o� w c� a zz o Ld �w z Z J J Q N DIGITAL INPUT BOARD 1A N M ,It Q ro N M � m (o r- m N M C) (n 00 -� N M a o 00- - N -M - N + 001 110A 1PR 16 SH 110B 1PR #16 SH 110C 1PR #16 SH 110D 1PR 16 SH TO DWG. 120.35.630 H ilmwa:=3[:lySI 105A 1PR 16 SH 105B 1PR #16 SH 105C 1PR 16 SH 105D 1PR 16 SH TO DWG. 120.35.630 +24VD( U ZSC--`� 7S0 1 ZS 5' �• a i , Zc M ZS-518 + !I f 3008 1PR 16 SH 100A 8PR 16 SH 100B 4PR 16 SH 100C RC62 COAX TO TO DWG. 120.35.625 DWG. 120.35.630 +24VUU P8 -24VDC P7 V) Lli J J z j w z 6 _o Z J D0 crN o m= DIGITAL INPUT BOARD 2A 401 ((� 2604 I ., `-16 #14 (PART OF CABLE 120B) COIL & TAPE SPARES 120 2' TO DWG. 120.35.629 h DIGITAL OUTPUT BOARD 2B +24PV8DC 501 -- -1 -24VDC 2604 P7 --i0 yusAKlu a- 503AR1 D 531-- _ P6 P5 - 534 P6 535 P6 P5 P6 --P5 j --1PR #16 SH (PART OF CABLE 112A) 006mbilli SVC-501 SVC-501 S .1 SVO-! 4 SVC-514 CVr-Fi 1 d SVO-519 SVC-519 SVC-519 U D 04 N 110 w m N 610 P6 P5 613 P6 P5 6t6 1 _-_P6 P5 619 P6 + P5 622 P6 P5 1108A 1 PR JIL 2 #14 (PART OF CABLE 11A) (08- 108A 1PR #16 SH 108B 1PR 16 SH 108C 1PR #16 SH 108D 1PR #16 SH 108E 9 C 14 108E_9 C 14 108G 9 C 14 108ii 9 C 14 1081 9 C 14 TO DWG. 120.35,646 N M Q cm N M m N U Lo (o LN Q ZEI COIL & TAPE 4 SPARE IN PANEL 11 1" TO DWG. 120.35.621 Ll 127A 1TR1 16 SH l 2-7BI 1 TRI # 16 SH 127C 1TR1 16 SH TO DWG. 120.35.630 DIGITAL OUTPUT BOARD 2D 701 YZ-2086-3 C 232� YZ-2086-3 N 0 '2321AI YZ-2086-1 + 23188 P3 LSHH-2050 (+`, LSHH-2050 PSL-2050 + PSI -2050 -i TY-566B + TE-5f"' TE-5br TE-566B B INTERNAL WIRING TO BE - DONE BY CONTRACTOR TIC-566B YC J/W TEMPERATURE CONTROLLER (MOUNTED IN F;\NFL) TO DWG. 120.35.629 TO DWG. 120.35.638 TO DWG. 120.35.637 TO DWG. 120.35.638 TO DWG. 120,35.637 ` ANALOG INPUT BOARD 5A - N - - Q 89 .. I_ `L -- { TRSH M PT im I M I d- PT-2054 + CD PT-2054 (- ! r PT-2005 (+-Co) --- INTERNAL WIRING ...... ... _..,„ N M I PT-20C6 + U- p PT-2006 - II `D I co PT-566 (+) L e0 - I PT-566 -) ! N 1- II PT-2065 +- w PT-2065 H II L co PT-2053 + PT-2053 H II N M PdT-2053 + tl l PdT-2053 H !I - 5E-2086 + - 835 4 L co SE-2086 (-)I I 836 --j--- a 991 6 I N ETSH_ M SS-2086 + SS-2086 - ! ! -837 ! ! 6951F - c9 COIL & TAPE - - I SPARES PT-501 + ° ^ PT-501 - - - PT-514 li oo --- PT-514 d = `0 - - TO DWG. 120.35.636 0 107 TO DWG. 120.35.646 1105AIlPR #16SH1 k 77 � s' ry I III I ANALOG IN T/ T/C T/C BOARD BOARD BOARD BOARD, BOARD 5B 82A 828 82C 82D TE-2080-9 + TE-2085-1A + - Y}; v' TE-2080-9 - N TE-2085-1A - I! N N--" , ".,., .., ItM TF 2080 2(+) Q TE-2080-10 + M Q, TE-2085-1B + Q L Q 1 ____2080" _ '0 TE-2080-10 H !! TE-2085-1B - ul + CD 0-3 - - TE-2085 1 - a N ? N CO TE-2085-2B + M m N udi ,a TE-2085-2B - !! -- - It co to m TE-2080-13 + TE-2085-3A + `O n Y TE-2080-13 TE-2085-3A H !I cC, �. ... -N N -r__ , —n U TE-2080-15 + U TE-2085-3B + ' U a TE-2080-1 TE-2085-3B - II - to In 04 2080 ° TE-2080-14 TE-2085-4A + cD r� _._ _ z TE-2085-4A - ! 2.080 y N TE-2080-14 N n %0BC - p p TE-2085-4B + Lo M p - ; _ L } "r TE-2085-4B - I t d- n L0 00 L co y co N M If p c0 I II Co N M T/C RTD RTD RTD -� wI BOARD BOARD BOARD BOARD I -1 82E 82F 82C TE-2087 R 82H 00- - TE-2085-5A + ,., --- TE-503-1 R ,� __ 1E-2282 (R „ w E-2085-5A -- Q TE5031 TE_2082 w II�_208iI TN N N B TE-2085-58 + T -5Q R E-200 15-58 (w I I ,n ,n TE-503- w Ul TE-2081 w_T- N - Q In D TE-503-3 R cO _ TE-2019 R I- O - O TE-2085-6A + - - - -- TE-2085-6A - !I TE-503-3 _ TE-2019 w 00-- - --- N I'17- - B N _ - D N N- to N- TE-2085-68 + -M� m _ >^ R m T -7_ R d-- m --�M-. m - TE-2085-6B (- -- _ 50-4 -- '- M TE-51 1 -1 w) T_ n n - 0 TE-2085-7A + `O ---f ( o- - I TE-2083 R U0 - - TE-51 1-1 w I TE-2083 w) I I _o N_... - - N - I I -o TE-2085-7B + 1 U - - R r7 U _ �T - 7 R TE-2085-7B - `fi — d- In - - w - w _U') -�n N__. TE-51 1-3 R tn_ _____ TE-201 1 R ( (o._ TE-511-3 w) I I - I TE-2011 w I I . N - - B N. - D I N N.. M M _ - - _ - --- a p � fE-511-4 - w 11 n (n COIL & TAPE i SPARES I 1PR #16SH (PART OF CABLE 112A) (60OV. INSULATION) 127A 1TR1 16SH 127E 1TR1 16SH 107A 1PR 16SH 107E 1PR 16SH NOTES: 1. THERMOCOUPLES, EXTENSION WIRES ARE FURNISHED WITH ENG/COMP. COIL & TAPE SPARES 115 - 1 I/2 111 165H 16SH 113 2" 165 TO DWG. 120.35.629 117A 1TR1 #16SH 1117E 1TR1 #16SH 1117C 1 TRI # 16SH 117D 1TRI E6SH 118A 1 TRI 16SH 118B 1TRI 16SH 118C 11R1 #16SH 118D 1TR1 16SH Y TO DWG. 120.35.630 COIL & TAPE SPARES 1 ISSUED FOR CONSTRUCTION 0 ISSUED FOR BID NO. REVISION - DESCRIPTION 119 2" 125 1" 119A 119E 1-8TR 1-8PR 125A PR 1 125B 1256 1PR 1 1TRI 1 TO DWG. TO DWG 120.35.629 120.35.630' LOG OUTPUT",; anAnn A 24 VDC + P10 - R TE-2087 R 24 VDC - P9 59611 + - 1004 PANEL 526AMB W TE-2087 W I AMBIENT g TE-2087 B a 5961I - ! 90151 10051 ! M _ - - - - I TEMP. Q SHIELD �' GOVERNOR 18 I GOVERNOR'- - r °p NOTE: CONTRACTOR TO MOUNT TEMPERATURE N SENSOR IN FIELD WITHIN CONTROL PANEL, NEAR THE TOP. CID TY-569 (+ oro N � U col N M In to r- DO DATE_ S22138 --- -- - - — DWG. STATUS CHECKED APPROVED DY DATE BY DATE BY - P.L. OR STA. ACCOUNT NUMBER -1994 CONSTRUCTION - - - -- — - BY DAL H PREL'Y BID - -- -- - DESIGN - -- DRAWN _ e./aj/)3' AS BUILT --- SM JCT - 9/2/93 9f 2/93 - - _ RLS 1/1 /9 —. __ CONSTR. --- -- PLOT DWG. ----- - - DATE: S22138 -- - --- .JAW MICRFLM ___- JCT -_-- BY --- 19/03/93 -_--- DATE .-.-. CHK'D•APP'D ---- CADDS -- - _ ----- -- - -- -- -- MICRFue FILE No. SCALE - - _ NONE ___ 2035637 GOVERNOR `INTERNAL WIRING TB1 24 VDC + 1..� 24 VDC - 2 PY-2054 + P3 Y 2.054 - 4 TO --5- TACHOMETER {--ci_ 6 17 INTERNAL WIRING 1 PR #16 SHLD TO I/P PY-2054 (WIRED BY VENDOR) PHASE III EXPANSION COMPRESSOR STATION NO. 20 ELECTRICAL UNIT PANEL INTERCONNECT DIAGRAM #2 FT. PIERCE, FLORIDA PREWIRED 1PR #16 Si T OF CABLE 115A) TO DWG. 120.35.638 181+ Bering DrIl - sane 41.5 UNIVF_RSAL PA. Ba. 520245 ENBLO, INC. Haueton.re.aa 77257-0248 (213) 977-77 20 IF EWRIM GAS PIPELM GROUP UP DRAWING NUMBER 120.35.637 1 Al 24VPD8C(+) 2DIT TB1 �603 _(+T - �INTERNALI 2001 (+ 7NTERNA 1I T1� P7 24VDC(+) ?- 3 _ )— Z J Q Z g �w j J z T a- 15 100A 8PR 16SH ICOB 4PR 16SH 100C RG62 COAX TO DWG. 120.35.636 10 DWG. 120,35.637 A224VDC(+) 24VDC(7 24VDC(+ 2DIT ENGINE SEQUENC'39EV-1(COOPER/BESSEMER) P4 IFY-2081 -- P3 P4 11 An",TERMINATIONS 39E1 (COO PER/ENTRONICS), Lj KZ-201 a2 VE-2082 I(-) Ill _VE-2082 + I VE-2082 S _ VF-2089 (C) I I i� 1 +24V 24RTN 2 INTERNAL WIRING - } TO FT50 0 (SIG) RST 7 OARD 1A ENG 6 (COM) (COM) 6 VIBR 639E1 # 1 24VDC(+) 24VDC(-) 39EV-2(COOPER/BESSEMER) P4 VJY-2082 P3 39E2(COOPER/ENTRONICS) WH4 VE-2081) K4 VE-2''" ` 1 g +24V (_V) 24RTN 2 4- tNTERNAL p t4WH3VE-2� 31 VE-2081 C a 0_fi'�I 9 0 (+V)K3 (SIG) RST ENG 7 .113 2' \ 24VDC(+) P4 F_--------- - -i P3 39C1(COOPER/ENTRONICS) 2514 )I 2515 2516 C2(COOPER/ENTRONICS). VE-2085-2 (-) VE-2085-2 + II VE-2085-2 s VE-2085-2 (c) I I 24VDC(+) P4 24VDC(+) P4 C3(COOPER/ENTRONICS) VE-2085-3 - 2527 VE-2085-3 + II 2528 VE-2085-3 s X " 2529 - VE-2085-3 C II 2530- II SHLD r� J, 24VDC(i-) C4(COOPER/ENTRONICS) VE-2085-4 (-) 25_33 VE-2085-4 + II VE-2085-4 s 2534 2535_ l VE-2085-4 C II 2536 SHLD TVL(COOP T1(COOPE 39TVR(COOPER BESSEMER) 39T2(COOPER ENTRONICS) wwnawy , l (-) 124A 2PR #16SH 124 124B 2PR #16SH 2' 124C 2PR #16SI1 TO DWG 124D 2PR # 1_6SH 120.35.630 VJY-2085-2 1 +24V 24RTN 2 INTERNAL WIRIN( 9 (A 5 TO FT50 10 (SIG) RST 7 BOARD 1A s (COM) (COM) 6 COMPR - VIBR 639C1 CYL 24VDC(-) VJY-2085-3 P3 .` 1 +24V 24RTN _ 2 _ ''1 'TERf RI (-V) 4 } TO FT50 9_ (+V) { 5_ BOARD 1A (SIG) RST 7 COMPR (COM) (COM) 6 _ VIBR _ 639C2 CYL #3' 24VDC(- - i iv nnoc n l P3 1-�+Z4V Z4KIN Z 8_ (-V) 4 -------= 9 _ (-+-V) 5 ---- o (SIG) RST 7 COMPR 6 (COM) (COM) 6 .• VIBR _ F .7__639C3 _ CYL #4'' 24VDC(- - --------- --- , I P3. VJY-2085-5 1 +24V 24RTN 2 _8 _ (-V) -4- 9 +V — 5 I- - Lo (SIG) RST 7 COMPR 6 (COM) (COM) �6 VIBR 639C4 CYL F VDC(+) 24VDC P4 VJY-2088 1 +24V 24RTN 23--� 8 (-V) 4 (+V) 5_ SIG) RST 7 TURBO (CO) 6- VIBR NAL WIRING 50 D 1A AN INTERNAL WI TO FT50 BOARD 1A_ll INTERNAL V TO FT50 METAL DETECTOR , FTB1- YJY-2002 AI_ is (7) (+) (1) G (2) DUAL PHASE (3) MONITOR (4) MOTHERBOARD COAX J9C RS232 J9A 24VDC(- P3 �j 24VDC(-) P3 - CID TION BY ATIONS ( RE) AE-2012-1 uWG. VntV11GU HI't'KW CU - OR V Y VNT NUMBER — -- - -- - - - -- - STATUS BY DATE BY DATE BY DATE 522138 _ Fonda Gas Transmission Company - - R sra Accou Houston, Texas - - - _ PREL'Y -- 1994 CONSTRUCTION PHASE III EXPANSION __- - DESIGN COMPBy DATE RESSOR STATION N0. 20 -- --- -- - - -- - GB 8 7f 93 BID -- - — DRAWN DDK 8 7/93 UNIT PANEL INTERCONNECT DIAGRAM #3 1 ISSUED FOR CONSTRUCTION 13B 11/1/93 r./`1!53[M�tl__E BUILT CONSTR.- -- -____ - - GRFLM FT. PIERCE, FLORIDA - _ —_- -- CADOS PLOT DATE: LE0 ISSUED FOR BID AS 93NO REVIS;ON DESCRIPTION BY DATE CHK'D APP'D DWG. S22138 2035638 cALE NONE 200.2(C� n2 . ei B<n�q UNIVERSAL P0. Box 5�0om<2.8'. E „r0. c i GAs rIPELINE CROUP � I DRAWING NUMBER �- 120.35.638 .j a a iJ -- - - - _ THROW _ I J� S 7+60 `'f I I I C31 W I BLDG. S 7+6791,C� I O I EXPANSION ND I I I I I L- -- ---------I #2/0(TYP.) 1 , ' #4 (TYP.) - - EXHA ST INTAKEINTIKE -- P-2022 I II rn N SUMP PUMP + i E PLAN ABOVE UHT I �, _ I IH I 71 -- 2080 + ` l LE-2080B ILENCE \ J SILENCER I I I I I I I W---------r -- -- _ -- -------- �' J �_ 1 II I I a -oo a I0000000 ; A V-2070 SWITCH RACK #4 , I I I I248 ( Y_I-iAl T 7' t H ' (� H I I I I I C-2030 I"AT / ___-_-_ II I I------------------------- ---------- -_ I- I I I I �S_83� 20' ------------- _ I I I I — — — — — — — — — — — — — — — — -- — --- — - ___—_------- I,-- ,r NOTES: I CONTRACTOR TO INSTALL BOTH MAIN GROUNDING SYSTEM AND LIGHTNING — --+-- PROTECTION SYSTEM EXISTING SIDEV ALK I (J I I I 1 -I-_1_-T--I- -_ I I i I 1 PBS 9 F01_LOWS CONDUIT DUCT BANK ---------- TO IJB-3 EXHAUST STACKS WILL UTILIZE TWO TERMINALS (DETAIL #1). BUILDING AIR TERMINAL LOCATION PER LIGHTING PROTECTION SYT. PLAN VIEW THIS DRAWING. 1 ISSUED FOR CONSTRUCTION 0 ISSUED FOR BID NO. REVISION DESCRIPTION E- e a e L E-4000 (ON EXHAUST STACK) OR E-4008 (ON BUILDING) ' DF1.pG E- 001 (ON EXHAUS Wlllllllllllllllllllllllll&STACK ONLY) AL/CU COMPRESSIO SPLICE BARREL (E 40 COPPER #2/0 INSULA (E 4010 tf��y�-{F DWG. STATUS _- CHECKFD BY DATE BY APPROVED DAI E -� ��`✓� - -1- - BY I _ DATE WORK .DER NUMBER _S221 M P_L. OR STA. ACCOUNT NUMBER --. 1994 CONSTRUCTION BY DATE DESIGN DM 8/18/93 DR�*N AS 8/18/93 AS euiLr - MICRFU/ MICRFTAI _ FILE NO. - SCAB -- 1 8'=1'—O" .. -- --- ---- - -- - -- icZjS� - - - - _ -- PREL'Y -_-- — BID AS ---- DDK -- BY 11/1/93 ----- 9/03/93 DATE - - - - CONSTR. -- -- CADDS -- - --- PLOT DW-G-- - - DATE S22138 - 2035639_- --- CHK'D --- APP'D TION Florida Gas hy Houston. Texas PHASE III EXPANSION COMPRESSOR STATION N(-). 20 COMPRESSOR AREA GROUNDING/LIGHTNING PROTECTION FT. PIERCE, FLORIDA E-4009 (TYP.) ---- AL/CU SPLICE BARREL GROUND ROD E— ENRON CAS PIPELIN.—:1; ._ DRAWING NUMBER 1 20.35.639 �. CHARGER AND BATTERIES TO EXISTING STATION CONTROL PANEL �IN EXISTING COMPRESSOR BUILDING SEE DWG. 120.35.615 FOFR CONTINUATION PHASE III TO ADD 27EMT,2/C#2 TRAY CABLES 129 TO INTERFACE PANEL 2005 1' D.C. LOAD CENTER 6 CIRCUIT PANEL UPS BATTERY RACK (E-0800) THIS I c ir EMERGENCY LIGHTING DWG. I DB THIS J A DWG. NEW PH.III CONDUITS _ N c� -FRONT DOOR 129 1' EMERGENCY LIGHT EXISTING 240VAC, l i PANELBOARD- EXISTING 1 u HVAC UNIT L- J' EXISTING 15KVA XFMR. 1 EXIST. 204VAC POWER FROM - AUXILIARY BUILDING )TOMATION CONTROL BI, EQUIPRANGEM SCALE: 1 /2" =1'-O" 90 COMPRESSOR BLDG. 1„ EMERGENCY LIGHTING CIRCUIT NOTES: SPARE 1. ALL CONSTRUCTION SHOWN WITH THE EXCEPTION OF THAT NOTED ABOVE IS TO BE NEW. 2. ALL CONDUITS AND FITTINGS INSIDE BUILDING SHALL BE EMT TYPE. c a LEGEND: M rn INDICATES EXISTING FACILITIES, EQUIPMENT AND WIRING INDICATES NEW CONSTRUCTION FOR W.O. #S22138 LM n NEW 2#8,1 #8GND. TO UPS (BLDG. 2), EMERGENCY LIGHTING UPS LOAD CENTER (BLDG. B) EXISTING & NEW ESD CABINET (DWG. 120.35._52 A 2- 1 1/2" CON la E-0735 SHUNT TRIP AT MCC SPARE (BLDG. 'OM El CABINET 14,1#14GND.) EXISTING 2#8,1 #8GND. 240VAC, 1 PH., 60 1 INCOMING POWER �.. 1 LIGHTS �\ 3 __PTACL 0— �� 5 C r /-� 7 ___0 0-- 15A. 0 � RE SPACE 11 12 SPACE SPACE a =7' 6 bA( I tKT UNAKUtK �\ IN ESD CABINET 4 0 0 RECEPTACLES -0 C— RECEPTACLES 20A. 0 0 - NEW UPS (BLDG. 2) 10�� 0 0 SPARE 12 SPACE 14 SPACE 16 SPACE iL I EXISTING - j' L2#4 . 24VDC FROM BATTERY CHARGER a 5A. ==0\0-- MAIN PRO OR I (FT100C) , 14)- o-3 15A. /� 5 UNIT #2001-0 0- 7 PANELTERFACE (2# 10) 0 15A. 9 UNIT #2002 --0 C - INTERFACE L (2#10)-0 O_ 15A. 13 UNIT #2003 0-- INTERFACE PANEL (2# 10) _0 - -INl 15A. 17 UNIT #2004 ERFACE PANEL (2# 10) __ 0 60AT 100AF PREL'Y EMT,' TO BLDG. FLOOR CABINET NO. 2 DRAWINGS EAST WALL A_ EMT CONDUIT TO SIDE OF TRAY AND- wk INSTALL INSULATING BUSHING 0 FT100C III TO ADD C#10 TRAY CABLES FACE PANEL 2005 D.C. 2" EMT LB FITTING LOAD CENTER 2" EMT HU87 PHASE III ADD _ ONE BREAKER 1/2"PVC,1#4 GND.- TO GROUND LOOP BLDG. FLOOR -� CABLES TO FIELD D (TYPICAL INSTALLATI( BLDG. FLOOR E-0782 E-0736 BATTERY CHARGER 15' WIDE CABLE TRAY i—CEILING 3/4" EMT W/4#16 THWN TO FT100C FOR CHARGER ALARM CONTACTS 3/4" PVC, 2#4 BATTERIES Y' WIDE CABLE 0 ,SECTION C—C ED ON Florida Gas Transmission Company Houston, Texas PHASE III EXPANSION COMPRESSOR STATION NO. 20 AUTOMATION CONTROL BUILDING ELECTRICAL PLAN AND DETAILS FT. PIERCE, FLORIDA DRAWING NUMBER 120.35.640 E-100 E-1318 DETAIL "5' (1 REQ'D) PR ,50�ER TRP 201P RTC �------ NspE't306 PIP E�10t9� —•- �1 E't2�9 ~y E'13 CONTROL E t51a 0 E'106 i �1 319 R U�ENT .INST PIPIN E'jp09 6 E'13t9 GOV GOV-520 GOV-2059 19 E'13 6 0 � E;120 1 � E�t319 NT INSTRU�E PIPING 51 a lE TINU R INC CP H �1ENT 1 ooa 45 G0V/20 IJPTO Of Est TO OT IN 3 NT PIR (� SPOWG) PIPING �NSTRU�E T NOTE: 1. INST. SUPPORT DESIGN & MATERIAL FURN. BY CONTRACTOR. DETAIL "6" ( 1 REQ'D) S201 d OIFFSSURE Vm .-" ,.I a.w, �',. Y '�' a'p.° .<. I 3.1 I Y } 1. 3 - . Ili I t, A_ GO 5'201 d FR00 T IS OG.) cOCPIL 6 FINEO �ApE G PERPTEO 0 RPTURE , , TE�PATING R GONjR � GO N�ROLLE 1318 � 0 ENT 1369 � �' INSTRUf� /E.t2g9 OUT 006 T �1319 PIEol006 E /1319 / j\\j� ,5660TO } 6,� EO 55 G6E1 OILEO RIP EXGE TO REO OVER GPS PNO SE U., ryP ; t TI C TIC-566B DETAIL "3" DETAIL "4" (1 REQ'D) (2 REQ'D) 01 TRPNSOUGERSEG O� kl2 E'1361 FN PIPING P N TY N-566B TY-566B N-569B TY-5696 DETAIL "7' (2 REQ'D) 1 ISSUED FOR CONSTRUCTION 0 ISSUED FOR BID NO. REVISION - DESCRIPTION q< 16 E'1004 E't3t8 EINSTRt, PIPING E'3 U 131 ' 1004 15 O�6a2 M E N T INSTR D _ E'1318 PIPING DETAIL "E (5 REQ'D) DWG. CHECKED STATUS BY DATE BY PREL'Y BID AS 1111193 CONSTR. — DDK 9/03/93 PLOT DATE: BY DATE CHK'D APP'D CADDS DWG. S22138 20, M w 00 LC I LV LC-2003 LV-2003 S22138 P.L OR STA. ACCOUNT NUMBE 1994 coNsTRucnoN BY DATE DESIGN _ CMH 07 30 DP—N - KJH 07 31 _S T - NONE m �L OLVE GONTR DETAIL "9" (1 REQ'D) 1611 Baring DrN - S i1e MO V N I V G.O. Boe 5]02M ':,,wc -. r+ '� +' r, ENSCO. INC. (713)9,77-7 ]]]A-02a8 770 Florida Gas Transmission Company Houston Texas cc'" Hk>hta er. 33 PHASE III EXPANSION ' ° _A COMPRESSOR STATION NO. 20 INSTRUMENT DETAILS FT. PIERCE, FLORIDA — — _—_— DRAWING NUu `� 120.35.641 1 TWO MAN t35Z E' E,t o°a URE * PREAGE d� GPU �P��E BYUPPIP / R r� r. �r.rni n rrur a nni irn E'131$ DETAIL " 10" (AS REQ'D) E'13/ 7/16"0 DRILL THRU 2 PLACES %L. AFTER �BRICATION INST. PORT E-1837 PdS PdS-514 E'1352 50 / I E'12 E 1004 GE'1 SURE * AGE 1513 DETAIL " 14' (,1 REO'D) NOTE: 1. INST. SUPPORT DESIGN & MATERIAL FURN. BY CONTRACTOR. 2. PLUG UNUSED PORT OF GAUGE VALVE W/ E-1532 0 V1 " 1 n rz� `'..F "` � ? sr)'•,. � rc.,;.fir.` �."." F 4 i'id Y w ',�, i! 1 F - rt ;% IPIP t: i I I a Ne I I I ir' v i I ' "19 E(PII, ,E nWG. 2" SCH. 40 PIPE CAP 9 2" SCH. 40 PIPE CAP P Q II � WELD 12•• 1 '211 47 ON EP H E'1315 5• BOTTOM 2" SCH. 40 PIPE 4 -�-- 2" SCH. 40 PIPE FINIS ED GRA E • °. .• .��.� �� ICI �--% � • °.• Pv�9y16 o . /> " / B o, o, — — CON RETE o, o, TYPE A TYPE B W."'rFllrlaxvknla� INSTRU�E N1318/, PIPING NOTES: ' 1. PRESSURE SWITCH MOUNTING AND INSTRUMENT SUPPORT DESIGN & MATERIAL BY CONTRACTOR 2. DOUBLE SWITCH CONFIGURATION APPLIES TO PSHH-514 F & PSH-514A ONLY, NO TWO —VALVE MANIFOLD (E-1201) n, REQUIRED FOR PSLL-501, DETAIL " 15' INSTRUMENT SUPPORT DETAILS NOTE: ----- ---- INST. SUPPORT DESIGN & MATERIAL FURNISHED BY CONTRACTOR. (SHOWN IS SUGGESTED SUPPORT DESIGN). - 1 ISSUED FOR CONSTRUCTION 0 ISSUED FOR BID NO. REVISION — DESCRIPTION •//,E'1318 0 DETAIL " 12" (2 REQ'D) E�131 r on,1312 .1315/ PIPING E pjpEp 0Tp,& NIS�E° REG 1R°��ER FIB/ GoN WITH TPIR DETAIL " 16" RU�ENT INS (1 REQ'D) NOT USED DWG. STATUS CHECKED APPROVED BY DATE BY DATE I BY PREL'Y — BID AS 11/1/93 CONSTR. AS 19/03/93 CADDS PLOT DATE: BY I DATE CHK'D APP'D DWG. S22138 2035642 I PS IARY .°��TOR GPPI�GUT IN�I Nofss PT E(TYP. 2) 's. (FL)U �� ( i NOTE: CONTRACTOR FIELD SURFACE MOUNT THERMOMETERS ON COMPRESSOR BUILDING WALL. (INSIDE BLDG.) DETAIL " 17 (1 REQ'D) WORK ORDERNUMBER21Florida Gas Transmission Company P.L. OR STA. ACCOUNT NUMBER Houston, Texas 1994 CONSTRUCTION PHASE III EXPANSION BY DATE oeslcN CMH COMPRESSOR STATION NO. 20 07 30 93 DRAWN KJH 07 31/93 AS BUILT _ INSTRUMENT DETAILS MICRFLM 111c FLM - - - - FT. PIERCE, FLORIDA FILE NO. SCALE : NONE 1811 Baring Drb - Suite 400 UNIVERSAL P.O. Box 570248 EHSCO. INC. HOVatPII.Texae 22257-C2" ® (213) 977-7770 M f N n .....,. .. .- ,. _.. r•.. IN i „I. �',. .,.,•n .'- .. �, u, r r ,, S II �I� 1 �Y ry J. . ,.,,.. .,u : , 'YP'X 4. .„ k.�. p«J' d . r , =, •.' y is` 5 x ,lm' 'ys }fi I: I P I r r r wc. r� r, Y r� an e e -Y. TO SUCTION LEAD LINE 1/2" PIPE (TYP. GAUGE BOARD 0 0 Ed o (0 0 I (0 LID O c0 D U-) (0 (O O O O O O 1 (D 1 1 1 FL FL FL E E-1345 E-1346 1 "6I 4 TO DISCHARGE LEAD LINE ON GAUGE BOARD 9 3 FACE z� 0 J M m 0- O V) w SEE DETAIL 21 - m THIS SHEET FOR a_ o TERMINATIONS U I SEE DETAIL 21 � m v 0 I NFL � N 0 N I d Q- 0_ 0_ d J8531 71 - - --- �91 Al 0 0 0 0 0 0 0 0 0 CONTROL PANEL j w oCD o� T NOTE # DETAIL 22 CONTRACTOR ENG./COMP. VENDOR BULKHEAD BAR #1 & #2 ON SKID STAINLESS (FURN. BY COMP /ENG. VENDOR) STEEL TUBING —fl 0 FLOOR COMPRESSOR GRATING SKID SS TUBING FROM -- BULKHEAD BAR #3_ �— UNIONS FOR TUBING TRANSITION FROM -- ---- - �` POLYETHYLENE TO STAINLESS STEEL. SEE DETAIL 23 MULTITUBE BUNDLES SEE NOTE #1 NOTES: 1. TUBING SUPPORT DESIGN MATE CONTRACTOR. UNISTRUT CONCRETE CLAMPS SHOWN AS EXAMPLE ONLY. w a 0 w p O r. Y 1- 3 FJ U Z 0 0 (� o O o (0 c0 c0 0 0_ Q W Q O Z Of 0 0 0 0 Z 0 Z) O N 0 N 0 N 0 N III O 0 EliQ N w rn (n N I I I I > w c0 w � N N 00 u 0_ (I 0) Q 0_ 13 --{22 23 --- L 4��I --t36 N t I M I d I L0 N Ih I I N I N I N O O O O O O O O u7 N u) u7 u7 N u') N 0- a}. d 0- 0- } a a Fe! AS SHORT AS PRACTICAL Y:r N M u7 N r7 r7 r7 d- O 0 O O O 0 O u) ul) u') uj uj a a a_ _EL STAINLESS STEEL TUBIN UNION OR BULKHEAD SWAGELOK INSERT (E-1336) POLYETHYLENE TUBING FIRE PROTECTION SLEEVE (E-1078) TIE BOTH ENDS WITH STEEL WIRES, SLEEVE MUST COVER ALL EXPOSED POLYETHYLENE TUBING 7-TUBE BUNDLE WITH FLAME RETARDANT PVC JACKET (E-1059) MINN SUPPORT & CLAMP =URNISHED BY CONTRACTOR-- SITI M It to I I 0 I 0 0 0 0 0 u7 u7 0 a } a BULKHEAD NOTE 3 (TYP. FC POLYETHYLENE TUBE BUNDLES) E-10 M8-1 c- MB-2 MB-3 MB-4e (TYP 54 PLACES) a Wit- I 00 00 Wit- 24I ao - d co 7X1/4'O.D.PE 7X1/4'O.D.PE ' '1 °0. 7X1/4'O.D.PE Q M r7 J E-1331 N N d- d- N N N N N Y N N N <t N N d- - s o 0 0 0 0 0 O 0 o J(r 0 0 0 o O 0 o m m -- - -- -- -- -- --- - -- -1336 LOCATE TRANSITION = 0 0 0 0_ o_ 0 0 01 0 o a 0 0 0 0 0 0 o F(TYP. FOR ALL BELOW FLOOR GRATING i i I I 1 i i mm i i I I i i i 1� 2f 3 13I 1f2 3 2 a' �3 POLYETHYLENE I+') W W W W W W W W W W W w w W W W 1 1 m— — -- — -- - - -- -- -- — — -- = — — — — T -- -__ _ -- -- T _- ---_-- --- STAINLESS STEEL �- --- ------ ------ --- --I F- -- - --------- --- -- - - -- -- I-- --- -- -- - - - - �. TUBES SEE NOTE 2 - I { { TUBING ABOVE 1 6 4 5R 5L 3 2 g 8 I 113 22 23 24 26 11 40 3� C C { C FLOOR GRATING --- ------ --- --- --- -_ L- --- -- i L-- ---- -- - - - - - - - - - j To-L L- - -- - - -- -- - - BAR- - - - -- --- - -- - -- --- J �BULKHEAD w.J -J J0_ } W CO o O W V) Q- p '� pW W d- J } N NN N F- N N F- NW O O O wD_ O Z J J 0' Q N N I Z Y Z L, Z 0_ Q FY F- F- F- I- QQ m O O O I Z O ZF- F- 0_ F- I- 0_ �- I-- Q_ O Q W w W W N w W 0_ N N ED to N CD Q. IL y d d d O d d 0_ d O Q- d Q_ 0. p 0_ a_ 0_ d Z 3 m m m = W z z w o w a Q- U z o w I V) N GO Q q Q Q D_ m y m 0 .... O O I 0_ 0_ O w 0_ U CWj = Lu _ = U Ed U = LLJ _ U Eli U = Ed Ed Ed = U U = _ _ FQ- U Z bi O O 0 CCD Z \ 0_ W J N O_ Z W H Q ti Q N N N N N 1")1")M n M � d- -Qj C9 0_ 0_ -O = >Q OJdj O O_ 7_ Ed ELI� )-} }� J)- }� J-J N } J} } J} }J co Lli Q Z J n oZ O U U U U U U UEli 1- Z0_ v a:W w w Ed O Z j w> OS N J -Ed O u� 0 o d DO: ~E-1345 vi Q —NOTE 1INST. E-1346 m j PIPING E-1347 Y7 m E-1318 �E-1318 1 � 8 a 2 ~ INST. _ _ INST. m m PIPING PIPING LEGEND w w 6 BULKHEAD CONNECTION ON UNIT PANEL I fl m m (FURNISHED BY VENDOR) \ \ BULKHEAD CONNECTION ON ENG./ COMP. SKID -- --- �_� BULKHEAD PLATE FURNISHED BY VENDOR ( ) SEE DWG. 120.60.602C 1------�---- ---i DETAIL 21 UNIT SUCTION UNIT DISCHARGE JOTES HEADER HEADER of 1. 150 PSIG AIR SUPPLY FROM INSTRUMENT AIR. AIR LEAD CONVERTS FROM 1 2' DWG. CHECKED APPROVED WORK ORDER NUMBER AT A POINT CLOSE TO UNIT PANEL OR ENGINE BULKHEAD. - --------- --- - - "-----"---- ---- "---- -- -- STATUS BY DATE BY DATE BY DATE S22138 PIPE TO 3 8' TUBE D 2. ALL TUBES ABOVE COMPRESSOR BUILDING GRATING FLOOR WILL BE -" -"- - - - - - - --- a.u. OR §T ACCOUNT NUNBEI STAINLESS STEEL, AND CONVERT TO HIGH -DENSITY POLYETHYLENE -- - _ -- --- --- TUBES IN BUNDLE WITH FLAME RETARDANT PVC JACKET BELOW FLOOR. - - - _- - -- — -- -- —— -- — - - -- - - -- Ic 1994 CONSTRUCTION 1 CONTRACTOR SHALL INSTALL PROPER UNION AND SS INSERT FOR REFERENCE PREL'Y --- - v } TUBING JOINT AND SUPPORT ALL TUBES AND MULTI -TUBE BUNDLES. CE DRAWINGS_ -- - -- - -- - _ _ BY - DATE AT THE ENDS OF THE MULTI -TUBE BUNDLE WHERE INDIVIDUAL POLYETHYLENE 120.35.612 COMP. BLDG. INSTRUMENTATION PLAN --- ----- ---- --- ----- --- -- -- ---- — BID - __ _ ___ DESIGN CMH 08/06 UBES SPREAD OUT AND LOSE THE PVC JACKET PROTECTION, A 120.35.613 I COMP. BLDG. INSTRUMENTATION PLAN -_- -_ --__ __- ._-_.__-- - ------ -- - - - -_ _-----__—_- ___-- _- -_ _ - - __-- -- DRAwN _KJH 08/061 FIRE PROTECTION SLEEVE SHALL BE ADDED ON EACH INDIVIDUAL 1 ISSUED FOR CONSTRUCTION AS 11/1/93 CONSTR. -----------� ------ As BUILT a POLYETHYLENE TUBE. SEE DETAIL 23 THIS SHEET. - MICRFUA TAG NUMBERS IN PARENTHESES ARE FROM PANEL VENDOR'S DRAWINGS. 0 ISSUED FOR BID AS 9/03/93 -"--- _-- --- -- -- MICRFLM -- -- L I 4. - - -- - ---_ --- -- — -- - PLOT_ DATE: 4 _.___---_-__--_... FlLE_NO_ NO. REVISION — DESCRIPTION BY DATE CHK'D APP'D CADDS DWG. \S22138\E\2035644 ScaiE NONE M Florida Gas Transmission Company PHASE III EXPANSION COMPRESSOR STATION NO. 20 UNIT CONTROL PANEL INSTRUMENT DETAILS FT. PIERCE, FLORIDA F�7T _}",5= I all &6" 06. - UNIVERSAL. P.O. 80. 570248 ENSCO. INC. HOu0oO Te.O> 77257-0248 (713) 917-7770 DRAWING Nuua�R 120.35.644 Al i C 24 VDC MAIN FIRE DETECTOR FAIL/TROUBLE 1-TB 1-29 1-TB 1-: TS1759 HTS,-"61 ��q I -0To- BLD . "� TO ESD CABINET (THIS SHEET) TD05TB2/V+ 2-TB1-1 2-TB1-2 I s ' OCR15 -------- ._._. _-----ESS-D--CABINET--------------------� I ' I I I I TO FT-100 TO FT-100 I I t 1 t II I ' I ( 2-TB1-1 2-TB1--7 I I I I I' 2 271 10 _- - ---- ter—_ HGX ( I I N 40% LEL GAS cal 40% LEL t CO m BLDG. B fm-- m GAS DETECT' 1 1 I I I I BLDG. B N N N N II t co cf) ~ ~ 2 271 10 I— ---- --c:. LGX j I I 20% LEL GAS N I 20% LEL m m BLDG. B m m GAS DETECTED I 04 GROUP A N GROUP B BLDG. B l N I ~ 2 245 10 1 UVFX I I ( I i FIRE DETECTED I �I �I FIRE DETECTED m m BLDG. B m m m m m BLDG. B I ~ I I I I N I ~ 6 ~ m I-- 2 2EFS 10 5 271LGX EXHAUST FAN START RELAY I;n I I TO FT-100 1 'f 11'• I 1 I p I N 2 10 HUN N I I m TRIP m I I r N AUX. BLDG MCC-2 I I I I 2 286 ESDX 10 ESD RELAY 1 ' 1 BLDG. B t I 1 I I' I I I I t I I N I I I I t m I t m m I I FI N 2EFS N I I 2 10 0 I 1 N I--- Gi I I `J 1 I N DO I I I I j286ESDX N I I c� 2 GDt I 0 I I I t CONTROL J-BOX SWITCHRACK #4 NOTES: 1. REMOVE WIRE BETWEEN RELAY 045UVFX (3) & RELAY 086ESOX-1 (9) & ADD CONTACTS 271HGX & 245UVFX. 071 10 --- ---- HGX1 40% LEL 40% LEL BLDG. A GAS DETECTED BLDG. A OCR16 2 045 10 - - UVFX1 FIRE DETECTED FIRE DETECTED BLDG. A RELAY BLDG. A ESD ARMED ESDX -_ 9 11 X1 X2 L BYPASS SWITCH -j ESD RESET ESD (PUSH LIGHT) PUSHBUTTON 071HGX1 045UVFX1 REMOTE OCR17 GAS CONTROL ESD 3 1 3 2 10 " I ESDX NOTE 1 I ��_ TO BE —j L--__ ADDED BY PHASE III 271 HGX 245UVFX�CONTRACTOR TO ESD CABINET 2-TB1-25 2-TB1-26 BLOWDOWN ESDX 031 SOLENOID 6 7 - 1 1 ISSUED FOR CONSTRUCTION 0 ISSUED FOR BID NO. REVISION — DESCRIPTION I I I TD05TB2/ GAS DETECTOR FAIL/TROUBLE -a 1-TB1-27 1-TB1- TS2-3 TS2-9 1-Gq• TD05TB2/5 FIRE DETECTOR Tw FAIL/TROUBLE 2-TB 1-13 TS1-TB1-41 TS1-TB 1-43 , BLDG. B GAS DETECT FAIL/TROUB 2-TB'f S2-TB1-8 TS2-TB2-8 BLDG. B (SEE DWG. 120.35.640 UPS LOAD CENTER BLDG.B t t CKT #2 I \ _ I 2-TB1-29 1 SHUNT TRIP AUX. M-T3 (IN ESD CABINET) -TB1-30 ST ST SWRK #11-1 (IN MCC #2) 071 HGX1• • .�. .�. •• : ' ♦ . •• BLDG. A HIGH GAS LEVEL Doc T§ .. 4" TO AUTODIALER -- - - DWG. STATUS CHECKED APPROVED WORK ORDER NUMBER S22138 BY _ DATE BY DATE BY DATE --- P.L OR STA. ACCOUNT NUMBER -_ _ _ PREL'Y 1994 CONSTRUCTION ---- --- -- --- - DESIGN -- DRAWN DATE BY DATE D`,"- JCT d O/ 93 BID _ -- ---- -- -- -- -- AS 11/1/93 - - - APP'D CONSTR. — -- -- rj `1 S - - - AS BUILT --- MICRFLM -MICRFLnt- FILE. NO. SCAIP t NONE AS - 9/03/93 _.- ,CHK'D - - - -- - — PLOT DATE: BY DATE 20 DWG. S22138 35645 CENTER ST ST SWRK #4 (IN MCC #2) LEGEND AVOMMIN OINDICATES FT-100C TERMINALS Z INDICATES FIRE/GAS CABINET TERMINALS 0 INDICATES ESD CABINET TERMINALS ® INDICATES AUTODIALER TERMINALS ® MOTOR STARTER TERMINALS 0 CONTROL J-BOX TERMINALS AT SWITCHRACK #4 Florida Gas e ransmissionm ompany Houston, Texas PHASE III EXPANSION COMPRESSOR STATION NO. 20 EMERGENCY S/D SCHEMATIC DIAGRAM FT. PIERCE, FLORIDA 1811 se-3 - a 1. -, _ i U N IV E R _S'A L_ P.0. 8a. 570248 E45c0 'c. Ha.ston?eros 77251-02.8 (713) 977 4270 IENRO N GROUP DRAWING NUMBER 120.35.645 PRESSURE VALVE SUCTION VALVE DISCHARGE VALVE CONTROL CONTROL DIFFERENTIAL DISCHAGRE VALVE SOV-502 SOV-501 PdS-514 STATUS GOV-514 OPEN OPEN -- ---- - ------ --- --------------- - SOLENOID SOLENOID I SVC-514(-) o SVO-514 - SVO-502 SVO-501 - SVC-514(WT) SVO-514(WT) —� SVC-514(+)i + PDS-514(BK) -+ SVO-514(+) SVO-501(+ --1 PDS-514(WT) SVO-501(- m SVO-502(+) C - - SVC-514(BK) SVO-514(BK) - C SVO-502(-) N ZSC-514 NO NO ZSO-514� rF Q_ NC NC I i U N O _m O it M d 1 a m i y DISCHARGE VALVE BYPAS� 1�' S VALVE SLOWDOWN VALVE CONTROL CONTROL CONTROL SOV-514 SOV-519 SOV-518 CLOSE OPEN SOLENOID SOLENOID SVC-501 SVO-514 SVC-501(+) SVO-514(+ SVC-501(-) SVO-514(- ;C ZS-514(BK) C I t_ _X -_� ZSC-514 NO ZSC-514(WT) ZSO-514(WT) - NO ZSO-514 NC NC 3/4" C. C C NO COIL & TAPE NO NCJ SPARES ANC ------ --- -- ICI 08F PURGE VALVE STATUS GOV-502 -SVO-502(WT) - - SVO-502(+)j + C SVO-502(BK) - I C NO NO ZSO-502 NC I NC C ZS-502(BK) --I C ZSC-502 NO ZSC-502(WT)-- ---ZSO-502(WT)- NO ZSO-502 NC NCI II C C-i NO COIL & TAPE NO NC SPARES NC SUCTION VALVE STATUS GOV-501 SVC-501(-) SVC-501(+) I ZSC-501 ZSC-501 I SVC-501(WT) SVO-501(WT) - SVC-501(BK) SVO-501(BK) - SVO-501 - SVO -501(+ ZSO-501 ZSO-501 (30% O1A 30% OPEN) I _ - + _ -+ C NO C NO NC C NO' NCj NC C ZS-501(BK)� ZSC-501(WT) COIL & TAPE SPARES -ZSO-501(WT) - ZSO-501(BK) NO NC C C NO NO NC NC -- - 1108G11-3/C #1I41 3/4" 108E 1-9C 14 108E 1-3C 14 1" 3 / 4„ 108C 1-9C14 108D 1-9C #14 108GlPR #16 SH 10BA 1-9C 14 108E I 1-9C f14 JB-3 108B1 1- 3/4" 2" 3/4" BYPASS VALVE STATUS GOV-518 SV-518(-) SVC-518(+) -_ SVC-518(WT) + _ C - SVC-518(BK)- iZSC-518 NO J' NC NC� C ZS-518(BK) C ZSC-518 NO ZSC-518(WT) ZSO-518(WT) - NO ZSO-518 NC NC C C, NO COIL & TAPE NO NC SPARES NC; I 1 ISSUED FOR CONSTRUCTION 0 ISSUED FOR BID NO. REVISION - DESCRIPTION CLOSE OPEN CLOSE SOLENOID SOLENOID SOLENOID SVC-514 SVO -519 SVC-519 SVC-514(+) SVO-519(+) SVC-519(+) SVC-514(-) SVO-519(-)� SVC-519(-) 108A 1-9C 14 1088 1-9C #14 108C 1-9C 14 108D 1-9C #14 108E 1-9C 14 JB-1 108H 1-9C #14 1081 41-3C14108J108K108L108M BYPASS VALVI- STATU S GOV-519 SUCTION PRESSURE DISCHARGE PRESSURE CLOSE PT-501 PT-514 SOLENOID L------� I----- -� SVC-518 - + - PT-501(+ PT-501(-)I PT-514(+) PT-514(-)I SVC-518(+) (BK) (WT) (BK) (WT) SVC-518(-) L---- -----j L- _1_J 107A 1PR #16 SH 107B1PR 16 SH - 3/4" 108A I 1-9C #14 108C 1-9C 14 108E 1-9C 14 108H 1-9C #14 108J 1-9C j14 108L 1PR #16 IVOJ I-7lJ IY 10�K 1-9C 14 SVC-519 - ----, - -- - --- - - - - - - - -- SVC-519(WT) SVO-519(WT) - SVC-519(BK) SVO-519(BK) - - - -+ SVO-519(-) SVO-519(+) ZSO-519 I ZSO-519 ZSD-519A (30% OPFN) SVC-519(+) + I-- ZSC-519 ZSC-519 - C C NO NO NC NC C NO ZS-519(BK)� ZSC-519(WT) COIL & TAPE SPARES ZSO-519(WT) - ZSO-519(BK) C NO NC NC _C- NO NC C NO NC DWG. CHECKED -- -- - - -- - STATUS BY DATE BY PREL'Y - -- - -- - DCM CONSTR. -- -- ------ AS 9/03/93 - - -- PLOT DATE BY ; DATE CHK'D APP'D CADDS DWG. S?2138--_-- 107A 1PR 16SH 107E 1PR 16SH UK & UNIT PANEL C-2005 SEE DWG. 120.35.636 PRESSUREIS' HIGH S/D'if PSHH-514 _ = N N a 0- TO VENT FAN 120VAC CONTROL SWITCHRACK #4 DWG. 120.35.621 24 24A 1PR '�1_16 S 3/4" GAS PIPING SUCTION PRESSURED PRESSURE LOW (VENT FAN ON) PSLL-501 PSH-514A. I I I I I I I M ^ m + + Q o � a J = a a �0 DECEIVED ' APPROVED WORKORDER U ER DATEBY _-DATE _S22138 i larida Gas Transmission Company P.L. OR SIX ACCOUNT NUMBER Houston Texas 1994 CONSTRUCTION PHASE III EXPANSION BY I DESIGN DATE COMPRESSOR STATION NO. 20 _ CH 8 4/93 - DRAWN JCT -8 4 93- UNIT GOV AREA INTERCONNECT DIAGRAM 9 t,. AS BUILT MICRELM — FT. PIERCE, FLORIDA ---_--_ _..._-_._-_---- - FILE NO.---___- 2035646 SCALE I NONE ] U N I'E— R-3 AL p.0. 9le. i 9nq 02 E"CO, 0. 2 ,7 25i-0249 713977-Yi 4 i a i A 4 GAS PIPELI I GROUP s DRAWING NUMBER ' 120.35.646/1\ T83 T84 CH. 4/RED JGD-2006 D(C) - CH. 3/RED JGD-2006 C(C) - CH. 2/RED JGD-2006 B(C) - CH. 1 /RED JGD-2006 A(C) - ESD CABINET #2 , 7W ni u �S i sV f2 I r I k I (III I TS2 TB1 1 FRAME GIRD. - - - - - - - 2 AC NEUTRAL 3 AC LINE 4 (-) BATTERY — 1 5 (+) BATTERY 6 - LOW ALARM COMMON 2-TB 1 -5� 7 TROUBLE N.C. 8 TROUBLE COMMON-TB1-� CH. 4/BLK JGD-2006 D(-) CH. 3/BLK JGD-2006 C(-) — CH. 2/BLK JGD-2006 B(-) CH. 1/BLK JGD-2006 A(-) COMMON RTN ---- -— — 271 HGX-2 ---_ ___ 40%LEL 20%LEL 271 LGX-2 - _ -- -- -- ------ - GAS TROUBLE FIRE_A FIRE B 245UVFX-2 -- ----- FIRE TROUBLE - ---------- — BLDG B HI LVL BL-- - DG B LO LVL { - ---- _..- 2EFS{ START FANS `- --- - - 271HGX ---------------21----------- 271HGX 245UVFX - - 245UVFX TO FT100 (BY OPERATIONS) 2—TB1 1 -TB 1-1 1 TB1 2 TS2-TB2-3 2 3 TS2 _TB2_ 4 - 4 TS2_TB16 _ 5 TS2-TB2-7 - - - TS2-TB1-8 7 -J 6 7 -- --- - --- TS2-TB2-8 8 TS1-TB 1_ 44 9 TS1-TB1-46_� 10 TS1-TB1-47 TS1-TB1-49 -- ----- TS1-TB1-42 TS1=TB1 43 - - - - --- -� 1-T81-27 11 12 13 14 15 16 17 18 19 20 1-TBl-28 1-TBl-31 --- 22 23 -- -- - 1-TBl-32 _ 24 25 26 27 28 1907AI 1PR #16 29 30 31 32 33 34 TS2 TB2 1 - N/C 2 N/C 2-TB13 3 HIGH ALARM COMMON 2-TBl-4 4 HIGH ALARM N.C. 5 HIGH ALARM N.O. 6 LOW ALARM N.O. 7 -LOW ALARM 1-7 N.C. 8 TROUBLE N.O. T65 1 2 3 4 a 5 CH. 4/WT JGD-2006 D(+) 6 - CH. 3/WT JGD-2006 C(+) 7 - CH. 2/WT JGD-2006 B(+) 8 - CH. 1/WT JGD-2006 A(+) TO EXISTING ESD CABINET SEE DWG. 120.35.645 TO ELECTRICAL SWITCHRACK #4 SEE DWG, 120.35.621 n FRAM GND 1 1ISSUED FOR CONSTRUCTION 0 ISSUED FOR BID NO. REVISION - DFSCRIPTION COMMON ENCLOSURE JFD2006-Al(BK) (+)24V JFD2006-A2(WT) 1 �AFU 24V-RTN - JFD2006-A3(BK) 3 JFD2006-A4(WT) 4 J 5 JFD2006- Bl(BK) 6 1AFU �J r JFD2006-82(WT) 7 \ JFD2006-B3(BK) 8 l� JFD2006-B4(WT) 0 I JFD2006-C1(BK) 11 tAFU Li � JFD2006-C2(Wi) j 12 \\ JFD2006-C3(BK) - 14 1 ll l JFD2006-C4(WT) I 15 JFD2006-Dl(BK) 16 1AFU J JFD2006-D2(WT) --- - - - 17 JFD2006-D3(BK) 18 \� JFD2006D4(WT) 20 22 23 \ 24 1 25 261 FU 27 28 -- ------ 29 30 31 32 904 904A 1- \ — / (LIAR 1 1_ TO COMP. BLDG. FIRE/GAS J-BOX DWG. 120.35.626 1. — PREL'Y BID RLS 1/1/93 - -_ CONSTR. DDK 9103193 BY DATE CHK'D APP'D CADDS R-7494 UV/IR CONTROLLER FR1 FR2 1 + 18 TO 35 VDC - GROUND 2 DO NOT USE 3 B1 ZONE 4 132 OUTPUTS 5 B3 6 B4 SIGNAL 7 INPUTS B5 (B-LEADS) 8 B6 FIRE LOGIC A/DATA STROBE OUT B7 FIRE LOGIC - B8 ALARM OUTPUT D1 EXT RESET/INHIBIT D2 OUTPUTS INHIBITED - D3 FAULT OUTPUT D4 SIGNAL EXTERNAL ACCEPT INPUTS --D5 (D-1EADS) R` "" D6 2 -D7 3 D8- STATUS 4- DETECAND TOR 5 OUTPUTS 6 7- DATA BUS 8 OUT 1 - 2 1p 3 -.- DATA 4- NOT USED BUS 5 NOT USED 6- DATA STROBE IN 7- DATA - NOT USED 8 USED CHASSIS (EARTH) GROUND 1 2 3 2 I 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 I 13 13 I I 14 14 15 15 16 16 17 17 18 18 19 19 20 20 21 21 22 22 23 23 24 24 25 25 26 26 27 27 28 28 29 29 30 30 31 31 32 32 TO EXISTING 24 UPS SYSTEM BYI DATE BY DATER BY S2213s P.L. OR STA. ACCOUNT NUMBER 1994 CONSTRUCTION _ BY — —_DATE DESIGN 8,7193, DRAWN DDK 8/7f 93 AS BUILT MICRFLM MICRFLM- FILE NO. SCALE NONE -- _ R-6007A UV/IR AUX. RELAY OUTPUT ASSEMBLY TS1 T81 NC ZONE 1 NO COM NC - ZONE 2 NO COM NC ZONE 3 NO- COM--- NC- ZONE 4 NO COM NC -- ZONE 5 NO COM NC ZONE 6 NO COM- NC- ZONE 7 NO- COM NC ZONE 8 NO- COM 9 41 10 42 11 43 12 44 13 45 14 46 15 47 16 48 17 49 18 50 19 51 20 52 21 53 22 54 23 55 24 56 25 57 26 58 27 59 28 60 29 61 30 62 31 63 32 64 SOLDER JOINT 0.47mm Fd 250VDC NON POLARIZED CAPACITOR (FURNISHED BY OPERATIONS NC 2-TB1-13(N 2-TB1-14(C 2--TB1-9 (NC NO 2-TB1-10(C 2-TB 1-1 l(NI NO 2-TB1-12(C NC NO COM londa Gas Transmission Company Houston. Texas PHASE III EXPANSION COMPRESSOR STATION NO. 20 E/GAS/ESD PANEL INTERCONNECT D1AGR� FT. PIERCE, FLORIDA FAULT FIRE A FIRE B ALARM I� i nss7-az<e DRAWING NUMBER ___.. 120.35.647 F�4' 24VDC + F10 P14 UNIT-2005 CONTROL PNL FT-50 UNIT 2005 J/W HYD. DRIVE CONTROLLER TIC-566B ! � � TE-566B UNIT 2005 J/W INLET TEMPERATURE TO TCV-566B TY-566B JACKET WATER COOLER FAN HYD. DRIVE DIVERTER IA UNIT 2005 JACKET WATER HYD. DRIVE CONTROL FUEL GAS FILT/SEP V-2050 L UNITS 1-4 SLL-2050 (+) PNEUMATIC 24VDC S/D SOV-2050 FT-100C V EXISTING PLANT CONTROL PNL IN CONTROL ROOM 4 FUEL GAS S/D CIRCUIT EXISTING UNIT SHUTDOWN INTERCONNECTION SCHEME I 0 � I E-0731 — - E-0732 E-0733 E-0734 I II 0 HS-565A/565B JACKET WATER CIRCULATING PUMP & HEATER CONTROL P-565 & H-565 --- EJ0731 E10732 (2) E 0735 I HS-202 & HS= 203 (2 REQ'D B —� I ' R �— O I I G E-0731 - H-A E-0732 jE0733 A -- I� I B �^ R }- 0 I G E-0731 --- H-0--A E-0732 E-0733 I A _a E-0734 VF-202 & VF-203 HS-2020 ` r 1SP 1114 (VF-202) 14 (VF-203) 228 9G' ' a4 PRE POST LURE OfL PUMP & HEATER CONTROL P-2020 & H-2020 DWG. - -- STATUS BY -____-- PREL'Y - - .. -- -- BID CONSTR. -- 1 ISSUED FOR CONSTRUCTION AS 1/1/9 -- --- PLC N0. REVISION - DESCRIPTION BY DATE CHK'D, APP'D CADDS DIN rN O. I G VF-201(PU CKED APPROVED WORK ORDeR NUMBER DATE BY DATE BY DATE S22138 --RI-OR STA. ACCOUNT NUMBEI 1994 CONSTRUCTION ---- ---- --- Bi DOTE DESIGN DM 10125 DRAWN AS_ 1pj 5 - -- - — AS BUILT MICRFLM ..._-_ -- --- - --. MICOFtm DATE: - --- - ---- - FILE NO. -- - S22138 2035649 SCALE NO LEGEND B UNIT IN AUTO PILOT LIGHT R UNIT RUNNING PILOT LIGHT UNITS) STOPPED PILOT LIGHT H-A HAND -AUTO SELECTOR SWITCH O-A 'ON -AUTO SELECTOR SWITCH H-O-A -HAND-OFF-AUTO SELECTOR SWITCH JMP PUMP CON P-701 Florida Gas Transmission Co Houston, Texas PHASE III EXPANSION COMPRESSOR STATION NO. 20 MISCELLANEOUS CONTROL SCHEMATICS FT. PIERCE, FLORIDA W call B.C." 0 S,i, "0 UN IV L_RSAL P.0 9a. 570249 ENY.O INC. Hoptan.Te.a, 17257269 (713) 977-7770 �t�N N C. oup DRAWING NUMBER 1 20.35.649 �., o 0 C> o .� N S. 1+00 "' W W 1N m z 0 DO PANEL BOARD a S. 5+00 S. 6+00 L-4WIM/ U/ V — JACKET WATER, LUBE OIL TURBO WATER COOLERS V-202Q ^. LUBE OIL RUNDOWN TANK SEE DETAIL II-3 THIS DWG. (TYP.) / SEE DETAIL II-6 THIS DWG. (TYP.) C- 4 BLOWDOWN SINGLE STAGE SILENCER COMPRESSOR S. 7+00 S. 8+00 SEE DETAIL II-1 THIS DWG. (TYP.) el Aar (i S. 9+00 7T SEE DETAIL II-1 — SEE DETAIL 11-5 THIS DWG. (TYP.) THIS DWG. SEE DETAIL II-2 - SEE DETAIL II-3 THIS DWG. •,,NT STORAGE -eWATERWELL #2 1 WATER TOWER THIS DWG. (TYP.) LUBE OIL STORAGE SEE DETAIL II-4 Y=2 WATERWFLI_ #1 THIS DWG. (TYP.) AIR RECEIVER ITCH RACK II-1 #1/0 CP - GND LOOP I 1 SEE NOTE 1 S E NO] F WATER TREATMENT BLDG. El' [T] 11' EXHAUST ♦rEE DTE STATION - _"ll AIR INLET COMPRESSOR BUILDING SUMPTANK -T SEE NOTE i DETAIL II-2 THIS DWG. E NOTE 1 NEW 18"0 SUCTI( NEW 18"0 DISCR EXIST. ITT SUC EXIST. 160 DISC SEE DETAIL II-3 THIS DWG. (TYP.) FU L SKID i1 BLDG. WALL I I BOLT TO WF 15 FIN. FL. CAULK \GUAB 47 " 2 STIR. RHWO SEE DETAIL "!i IICABLE 25 A GRADE 6" DIA. AUGER HOLE 920 •T •� •� •� s_s_s_ 16 31 % ` • ` % � L 0. NOTE 3 • k. PLASTIC C. BUSHING 17 SHERMAN 15 26 TAP CONN. LOOP 14 25 #2 RHW. CABLE GO 1.4" X 1.4" X 5' - 0O ZINC ROD - BACKFILL #5 INSTALLED DRY AND O2 WELL TAMPED 3 SUPPORT S GRADE Go THERMITE WELD 03 PVC CONDUIT j14AWG, GRN O DETAIL II-2 TYP. STEEL, COLUMN Sc VESEEL GROUND 13 14 CADWELD MOLD CADWELD CONNECTION MAIN GND LOG;' [MAIN GND LOOP Z // 4 #1/0 #1/0 O4 O #4 AWG GRN (TO GND ROD) l 11 CP (TO GND LOOP) TA (#4AWGP GRN)O6 24 11 DETAIL II-3 ADE7 IL "A WELDED GROUND CONNECTION BELOW GRADE DETAIL II-1 TYPICAL ANODE INSTALLATION EF9010IN HANDHOLE GRADE DETAIL II-4 TYP. SKID GROUND i y i DETAIL II-5 FLOODUGHT POLE GROUND O DR O GROUND LOOP CT �- #4 AWG, GRN SIZE 1.4"x1.4"x60 BILL OF MATERIAL DESCRIPTION ZINC ANODE, W/ IF GALV. STL. CORE, AMERICAN ZINC INSTITUE, NO. A71-2-30 BACKFILL, COMPOSE OF 50% BENTONITE & 50% HYDRATED GYPSUM CONDULET, C-H # GUAB47 MARK QUAN BILL OF MATERIAL MARK QUAN SIZE lle x 6" - DESCRIPTION 1 15 --_ NIPPLE, GALV THREADED RIGID CONDUrr CONDUIT, GALV. THREADED, RIGID CONDUIT 2 #5 16 11C" 11E" 1f2" 3 11C" 17 BUSHING, PLASTIC CONDUIT STRAP, 1 HOLE GALV STEEL MASONRY ANCHORS, FOR IC" 20 BOLTS 4 1/0 CONDUCTOR, SINGLE, TYPE THHN/THWN, GREEN 18 5 GROUND LUG, #4 WIRE, BURNDY #KPA25 19 IF "x20xl" LG 6 #4 AWG 1" CONDUCTOR, #4AWG, TYPE THHN/THWN, GREEN 20 SCREW CADIUM PLATED STEEL SOLDERLESS LUGS,-OZ. NO. X1-011 FOR #2 WIRE SOLDERLESS LUGS OZ. NO. XL041 FOR #6 WIRE 7 CONDUIT, PVC W/ END BELL, SHORT RADIUS, SCHEDULE 40 21 8 CADWELD MOLD #4 TO FLAT SURFACE, ERICO PRODUCTS #VSC-IL CADWELD METAL CHARGE, ERICO PRODUCTS WELD METAL #45 22 7-18x1?" 9 23 BRASS BOLT, W/ HEX NUT 10 1° - ONE HOLE PIPING STRAP, HOT DIP GALVANIZED, T&B 1278 24 #6 STIR. RHW. COPPER CABLE, ANACONDA DURA-SHEATH STIR. RHW. COPPER CABLE, ANACONDA DURA-SHEATH CONNECTOR SHERMAN SET SCREW NO. 70 SCOTCH N0. 33 ELECTRICAL TAPE _ - _- 11 EQUIPMENT GROUND SERVICE POST FOR #8-#2 AWG, BRUNDY #KC23 EXPANSION ANCHOR C/W NUTS, GALVANIZED, RAMSET TURNBOLT CADWELD MOLD _- 1/0 TO #4 TAP, SPLIT CRUCIBLE TYPE, ERICO PRODUCTS #TAC-2CIL-L CADWELD MOLD, #4 TO FLAT SURFACE, (USE CHARGE #45), ERICO PRODUCTS #VSC-IL 25 #2 12 IC" x 31E° 26 #1 13 14 27 NOTES: 1. PHASE II EXPANSION GROUND LOOP TO BE CONNECTED 3. THIS DIMENSION WILL VARY ACCORDING TO TO EXISTING GROUND LOOP PER RESIDENT ENGINEER. LOCATION, EXACT LOCATION BY RESIDENT ENGINEER. 2. ALL GROUND DITCHES TO HAVE RED WARNING TAPE 4. THIS DIMENSION WILL VARY ACCORDING TO INSTALLED PER RESIDENT ENGINEER. FINISH FLOOR ELEV.. DWG. _CHECKED APPROVED WORK ORDER NUMBER J" STATUS BY DATE BY _ _DATE BY DATE S22138 _ P.L. OR STA. ACCOUNT NUMBER 1994 CONSTRUCTION PREL'Y - - -- -- ---- BY DATE ---- - - --- DESIGN DM B/1V93 — BID --- - - - - - - - - -- DRAWN AS _8/18/93 AS 1 ISSUED FOR CONSTRUCTION DCM 11/1/93 CONSTR.- - —I` ILT MICRFLM _ 0 ISSUED FOR BID AS 9/03 93 -- PLOT DATE: _ _ _____._ FlM-16�No�" - __ LE - - - CADDS — kin PFUlalnnl - r)P if RIPTInN Rv nATF CHK'n' APP'D nwr,. FGF-1 RR4D-5109 SCALE 1" = ` o' DETAIL II-6 TYP. GROUND FROM INSIDE BLDG. TO OUTSIDE GROUND LOOP NOTE: THIS DRAWING IS FOR PHASE II EXPANSION ONLY. FOR PHASE III EXPANSION SEE DWG. 120.35.639 J 4/ RN D - PVC CONDUIT (- -� ., unnq o,;- - 5.%4 .00 UNIVERSAL P0. 9a. 57C2.8 M" 0, '"C. "ooNon,4m. 71257-02. �{ ) (71.1) 977-7790 Florida Gas Transmission Company Houston, Texas ENitQ®lire PHASE III EXPANSION GoAS PIPELINE COMPRESSOR STATION NO. 20 GROUP EXISTING STATION GROUNDING PLAN L, FT. PIERCE, FLORIDA DRAWING NUMBER _ 120.35.650 t 3-i:.y a z"IM I II 1 1 C p 5 I _ _ 16 Pr_ O 3" MYERS HUB Q Q 1" MYERS HUB 1 1/2" C 1" MYERS HUC MYERS HUB 1 /2" LIQUIDTIGHT i CONNECTOR 13 I 10 FURNISH BY " LIQUIDTIGHT - AIR COMPRESSOF CONNECTOR �- ;7 30 KVA f VENDORS t 1" MYERS 1" LIQUIDTIGHT - ;� HUB LEX CONDUIT 12 -1" LIQUIDTIGHT /WELDING ANGLE CONNECTOR1 1/2' LIQUIDTIGHT RECEPTACLE ANGLE CONNECTOR 1 1/2" LIQUIDTIGHT FLEX CONDUIT- I- -1 /0 SERVIT POST Tf� --- --- - - �- - ! % ---- -- = - o IICD > W Nz ' _j OD 00 64 a -� O I F- OLLJ d O U F W c:: _j F_ U � O F- it U 0 3" MYERS d - ---- - - HUB �r ,i 'e 1 ( 1 2 1 3 4 1 6 7 8 19 - 1"GUAT--, (TYP.4) ; - 3" MYERS HUB3 13 - - �'7 3" CONDUIT (BY OTHERS) IT I I I I I I I I I I I I I I -DECTION "C-C SWITCH RACK SCALE 3/4"=1'-0" RGS CONDUIT 1 1 /2" CONDUIT (BY OTE 1" CONDUIT (BY OTHERS) '3ECTION "B-B" SWITCH RACK SCALE 3/4"=1'-O" 1" MYERS HUB FURNISH BY AIR COMPRESSOR VEN I - "�, 0 ISSUED 10R R D~ NO. REVISION L7 18 1 1 15 1 1 ,' 2 I 3 -rI 4 I 5 i BUS MI II DUCT 41R 1PR. DOR )UCT HANDLE TYR. REMOVABLE COVERS (TYP. BOTH SIDES). A �j 13 I �- 400 A BUS EQUIPMENT LIST UNIT FUNCTION DESCRIPTION NUMBER NAMEPLATE MARKING 1 400A DISCONNECT SWITCH 30, 480 V, 400A, NF DISCONNECT SWITCH NEMA 4 ENCLOSURE EATER 15KW, CONTACTOR SIZE 2, COMBINATION 48OV, 30 60 CYCLE NEMA 4(DUPLEX) - 3 J.W. HEATER CIRC. MOTOR STARTER SIZE 1, COMBINATION 48OV, 30 P 3 H.P. P-565 60 CYCLE NEMA 4(DUPLEX) " LOBE OIL HEATER 26KW, CONTACTOR SIZE 2, COMBINATION 48OV, 30 H-2020 60 CYCLE NEMA 4(DUPLEX) 5 PRE/POST LUBE OIL MOTOR STARTER SIZE 1, COMBINATION 48OV, 30 PUMP P-2020 7.5 H.-P. 60 CYCLE NEMA 4(DUPLEX) 6 COMPRESSOR BLDG. 2 MOTOR STARTER SIZE 1, COMBINATION 48OV, 30 VENT FAN VF-201 2H.P. 60 CYCLE NEMA 4 7 COMPRESSOR BLDG. 2 MOTOR STARTER SIZE 1, COMBINATION 480V, 30 VENT FAN VF-202 2H.P. 60 CYCLE NEMA 4 8 COMPRESSOR BLDG. 2 MOTOR STARTER SIZE 1, COMBINATION 48OV, 30 VENT FAN VF-203 2H.P. 60 CYCLE NEMA 4 9 WELDING RECEPTACLE CIRCUIT BREAKER NEMA 4, 30 CIRCUIT BREAKER 480 V, 30 A _ :....::C M:50:.:.....:..:M taR::SrkRYfR::Sf > ::4:: 6 f.::S............ :ST�rE:.: ......:: ::.:..:...:....C.-2fl3fl.....:.:..:..:........... 480:: V .:3 ; ;C�O;•;GYG E; ,NEMA. ¢:::::..... I .............:.:......... . COMPRESSOR BLDG. 2 _ 24 CKT. LIGHTING PANEL, NEMA 4, 120/208V, 30,WITH LIGHTING PANEL 100A MAIN BREAKER, 1-3P,30A, 3-2P,20A AND 8-SP,20A BREAKERS 12 30 KVA TRANSFORMER 30 KVA 480-120/208V, 30, 60 CYCLE 4-WIRE TRANSFORMER 13 TRANSFORMER 100AF 40 AT T.M. BREAKER/ WITH NEMA 4 FEEDER BREAKER ENCLOSURE 30, 480 V 14 LIGHTING CONTACTOR CONTACTOR SIZE 1, 208, 30, 60 CYCLE, NEMA 4 WITH H-O-A SWITCH 15 FLOODLIGHT 12 CIRCUIT LIGHTING PANEL, NEMA 4, 120/208V, 30, LIGHTING PANEL 4 WIRE, WITH 3 DP 20A AND 3 SP 20A BREAKERS 16 12'-0", 48OV, 400A,30 BUSWAY W/GROUNDING BUS W NEMA 3R REMOTE PHOTOCELL CROUSE-HINDS CAT# DS-60 17 (MOUNT IN NORTH END OF BUSWAY) 18 COMPRESSOR BLDG. 2 M01OR STARTER SIZE 1, COMBI SUMP 1 .P., P-2022 60 CYCLE NEMA 4 19 CONTRO BOX 24"H X 18"W X 8"D NEMA 4 -- 1/4" WEEP HOLES AT APPROX. 12" CENTERS ERENF DRAWINGS: 120.35.691 ELECTRICAL SWITCHRACK ASS 120.35.604 ONE -LINE POWER DIAGRAM 120.35.605 ELEMENTARY DIAGRAMS 120.35.609 COOLER FAN AREA 120.35.635 MISCELLANEOUS DETAILS SHT.#3 } ston Texas ;LE HASE III EXPANSION RESSOR STATION NO. 20 CTRICAL SWITCHRACK ASSEMBLY FT. PIERCE, FLORIDA ,. ,t- 2 _t , imi 3l,lIrl, D swFe <.q U NIVEF2SAL F.D 9•57021 E.vs O INc_ H , ,lcya ])257- a2-a (7u) W] -T]JD KW DRAWING NUMBER 120.35.691 p ]s{)1 i tltlA l L q 4 •air y I�I ts" V i. 5ka f M� 4 * YA t e i�. F r �{ 3n M.S"N f � N ;•u 1 � h , k. °Sy Y pCV�4 k e �`„✓�.,� �y¢ mom, @,. '%��� 3�,�?� � a � �� L}"'raiyrF'k1 4k{E .fin ,a.j{ P cme�'a '. < c d 4 S E F tM alF d[`i y t HF4 P �Sd*'.y�.k ^timed nl'tl .v'I+i. �h3 � i3 id y t