Loading...
HomeMy WebLinkAboutInspection Docs wrightsoft® Project Summary Job: Date: Entire House By. QUICK CALCS, INC. 317 ST.LUCIE LANE,FORT PIERCE,FL 34946 Phone:772-46&6799 EM8*11:QUCKCALCS@AOL.COM F Pobject Information For. EILEEN TILTON 5306 HICKORY DRIVE,FT PIERCE,FL 34982 Notes: l rmation Wisign •info Weather., Fort Pierce,FL,US WinterDesignConditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 14537 Btuh Structure 14277 Btuh Ducts 4069 Btuh Ducts 6064 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh none (none} (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 18606 Btuh Use manufacturer's data n Ratelswing multiplier 0.95 Infiltration Equipment sensible load 19324 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1428 Btuh Ducts 1631 Btuh Central vent(0 cfm) 0 Btuh HeatingCooling (none), Area(ft2) 1111113 Equipment latent load 3059 Btuh Volume(ft3) 8920 8920 Airchanges/hour 0.45 0.23 Equipment Total Load(Sen+Lat) 22383 Btuh Equiv.AVF(cfm) 67 34 Req,total capacity at 0.70 SHR 2.3 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade EXISTING SYSTEM Model Cond CA14NA03600GOA0 AHRI ref Coil FB4CNF036L AHRI ref 9193892 Efficiency 100 EFF Efficiency 12.0 EER,14 SEER Heating input 7.8 kW Sensible cooling 23100 Btuh Heating output 26550 Btuh Latent cooling 9900 Btuh Temperature rise 50 OF Total cooling 33000 Btuh Actual airflow 483 cfm Actual airflow 1100 Cfrn Airflow factor 0.026 cfm/Btuh Airflowfactor 0,054 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.87 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. t-SLi RighteOUniversal 201919.0.07 RSU08101 2020-Mar-1116:22:06 ACCK CK\DoamertsNWrightsoftliVAC\*nLTON,EILEEN.rup Calc=MJB Front[Doorfares:W Page 1 | wrightsofto Duct System Summary Job: Entire House By. QUICK CALCS, INC. 317 ST.LUCIE LANE,FORT PIERCE,FL34946 Phone:772-466-6799 Email:QUCI<CALCS@AOL.COM 5306 HICKORY DRIVE,FT PIERCE,FL 34982 Heating Ex�mam��pmo�m 0.50 �H2O 0.50in - Pressure losses 0.28 in H20 0.28 in H20 Available static 0.22 in H20 0.22 in H20 Supply/return available pressure 0.171/0.049 in H20 0.171/0.049 in H20 LcWeatfMoUunnste 0.080 inMUDD 0.080 inM80ft Actual air flow 483 chn 1100 ohn Total effective length(TEL) 155 ft . Supp'Jy' Bra nch Detail Table Design Htg Cig Design Diarn HxW Duct Actual Ftg.Eqv Name (Btuh) (Gfm) (drn) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk BATH C 1162 35 63 0.080 4.0 OX0 VIFx 30.8 90.0 st'! BATH 2 C 552 23 30 0.080 4.0 OX0 V1Fx 4.1 70.0 BEDROOM c 2949 88 159 U80 8.0 OX0 V1Fx 26.4 90.0 sti BEDROOM2 c 2984 89 161 0.080 7.0 OX0 VlFx 8.0 70.0 BEDROOM3 C 1409 54 76 0.080 7.0 Ox 0 VlFx 10.0 70.0 WCHENDINING C 6088 97 329 0.080 8.0 ox 0 VIFx 10.6 70.0 LIVING c 4945 85 267 0.080 8.0 Ox 0 V1Fx 8.9 70.0 | . Sup .P!y Trunk Detail Table Name Type (cfm) (cfrn) FR (fpm) (in) (in) Material Trunk wrightsoft- Righ-SLitee Universal 2019 19,0.07 RSU081 01 2020-Mar-11 1622:06 Z6A K\DoumentsWrightsoft HVAQ71LTON,EILEEN.rup Calc=MJ8 Front Door faces:W � ' u Rety',h Prahch DetAil Table Grille Htg Cig TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (CfM) (GfM) (ft) FR (fpm) (in) (in) Opening(in) Mat Trunk rbI Ox 0 173 427 34.5 0.142 306 16.0 Ox 0 \AFx rb4 Ox 151 405 0 0 0 0 Ox 0 \AFx rb2 Ox 0 48 77 0 0 0 0 Ox 0 \AFx rb3 Ox 111 191 0 0 0 0 Ox 0 \AFx 1wr gigtt-sLitesuriversa]201919.0.07RSUOSIOI 2020-Mar-11 162206 CK\DocLynerts\WrightsoftHVAC\HLTON,EILEEN.rup Calc=MJ8 Frorl Door faces:W Paget