Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Inspection Docs
Job: - - Wrightsofto Project Summary By. UNIT# 1 QUICK CALCS, INC. 317 ST.LUCIE LANE,FORT PIERCE,FL34946 Phone:772-466-6799 Email:QUICKCALCS@AOL.COM ProJect Information For: NORMAN STAUB 7847 SABAL LAKE DRIVE,FT.PIERCE,FL I Notes: Pdsian Information Weather: Fort Pierce,FL,US Winter Design Conditions Summer Design Conditions Outside db 42 °F Outside db 90 'F Inside db 70 'F Inside db 75 'F Design TD 28 'F Design TD 15 'F Daily range M Relative humidity 50 % Moisture difference 61 grub Heating Summary Sensible Cooling Equipment Load Sizing Structure 11048 Btuh Structure 9889 Btuh Ducts 2519 Btuh Ducts 3829 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 13567 Btuh Use manufacturer's data n Rate/swin multiplier 0.95 Infiltration Equipmensensible load 13033 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1927 Btuh Ducts 1010 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft') 906 906 Equipment latent load 2937 Btuh Volume(ft') 8154 8154 Airchanges/hour 0.37 0.20 Equipment Total Load(Sen+Lat) 15970 Btuh Equiv,AVF(cfm) 50 27 Req.total capacity at 0.70 SHR 1.6 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade CARRIER Model Cond 24ACB724AO0310 AHRI ref Coil FV4CNF002L AHRI ref 10359317 Efficiency 100 EFF Efficiency 13.0 EER,16 SEER Heating Input 3.8 kW Sensible cooling 17360 Btuh Heating output 12.947 Btuh Latent cooling 7440 Btuh Temperature rise `50 °F Total cooling 24800 Btuh Actual airflow 236 cfm Actual airflow 827 cfm Airflowfactor 0.017 cfrnBtuh Airflowfactor 0.060 cfm/Btuh Static pressure 0.08 in H2O Static pressure 0.08 in H2O Space thermostat Load sensible heat ratio 0.82 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -F�*- w1r19htsoft� 2020-Mar-1114:15:32 �"•r=^e aw a^- Right-Siite®Uriversa1201919.0.07 RSU08101 Pae 1 ACOA 9 ...ICK1Doamerrts\WrightsoftFNAC4STAUB,NORMAN.nq� Calc=MJe Front Project Summary Date: - wrightsofte UNIT#2 By. QUICK CALCS, INC. 317 ST LUCIE LANE,FORT PIERCE,FL34946 Phone:772-466-6799 Email:QUICKCALCS@AOL.COM' a - o • For: NORMAN STAUB 7847 SABAL LAKE DRIVE,FT.PIERCE,FL Notes: � - •n,,Information Weather: Fort Pierce,FL,US Winter Design Conditions Summer Design Conditions Outside db 42 of Outside db 90 °F Inside db 70 °F Inside db 75 °F Design TD 28 °F Design TD 15 °F Daily range M Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 24374 Btuh Structure '27567 Btuh Ducts 8430 Btuh Ducts 12026 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 32804 Btuh Use manufacturer's data n Rate/swin multiplier 0.95 Infiltration Equipmenq sensible load 37613 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1681 Btuh Ducts 3430 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ftp 2268 2268 Equipment latent load 5111 Btuh Volume(fl3) 20412 20412 AirchangesAiour 0.22 0.12 Equipment Total Load(Sen+Lat) 42724 Btuh Equiv AVF(cfm) 75 40 Req.total capacity at 0.70 SHR 4.5 ton Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox Trade LENNOX Trade LENNOX Model XP25-048-230-** Cond XP25-048-230** AHRI ref 5947731 Coil CBX40UHV-048*++TDR AHRI ref 5947731 Efficiency 9.7 HSPF Efficiency 13.0 EER,20 SEER Heating Input Sensible cooling 33600 Btuh Heating output 47500 Btuh @ 47°F Latent cooling 14400 Btuh Temperature rise 27 °F Total cooling 48000 Btuh Actual airflow 1600 cfm Actual airflow 1600 cfrn Airflowfactor 0.049 cfm/Btuh Airflowfactor 0.040 cfm/Btuh Static pressure 0.08 in H2O Static pressure 0.08 in H2O Space thermostat Load sensible heat ratio 0.89 Capacity balance point=32°F p Backup: kup: Input=9 kW, Output=32292 Btuh,100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -Flawrightsoli t® 2020-Mar-11 14:15:32 Right-Stite®UNversal201919.0.07 RSU08101 Page 2 ACCk ICK1DoaanentslWdghtsoftHVAC1STAUB,NORMAN.np Calc=MJ8 Front Door faces:SE ® Project Summary Date: - - wrightsoft UNIT O By. QUICK CALCS, INC. 317 ST.LUCIE LANE,FORT PIERCE,FL34946 Phone:772466-6799 Email:QUICKCALCS@AOL.COM • • I NMI • For: NORMAN STAUB 7847 SABAL LAKE DRIVE,FT.PIERCE,FL Notes: D&Ign Information Weather: Fort Pierce,FL,US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 grub Heating Summary Sensible Cooling Equipment Load Sizing Structure 16308 Btuh Structure 13854 Btuh Ducts 2981 Btuh Ducts 4397 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 19289 Btuh Use manufacturer's data n Rate/swin multiplier 0.95 Infiltration Equipmeniq sensible load 17339 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1712 Btuh Ducts 1166 Btuh Central vent(0 cfm) 0 Btuh Heating' Cooling (none) Area(ft2) 1209 1209 Equipment latent load 2878 Btuh Volume(ft) 10881 10881 Airchanges/hour 0.32 0.17 Equipment Total Load(Sen+Lat) 20217 Btuh Equiv.AVF(cfm) 59 31 Req.total capacity at 0.70 SHR 2.1 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade CARRIER Model Cond 24ACB724AO0310 AHRI ref Coil FV4CNF002L AHRI ref 10359317 Efficiency 100 EFF Efficiency 13.0 EER,16 SEER Heating input 7.8 kW Sensible cooling 17360 Btuh Heating output 26550 Btuh Latent cooling 7440 Btuh Temperature rise 50 OF Total cooling 24800 Btuh Actual airflow 483 cfm Actual airflow 827 cfm Airflowfactor 0.025 cfmBtuh Airflowfactor 0.045 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.86 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 2020-Mar-11 14:15:32 .� wrightsoTt� - �� ^-�^^••^•-yv^P� RigM-Sute�l Urtiversa1201919.0.07 RSU08101 Page 3 ICK1Docunents\WrightsoftWAC\STAUB,NORMAN.np Calc=MJ8 Front Door faces:SE Wrights®ft° Duct System Summary Date: UNIT#1 B� QUICK CALCS, INC. 317 ST.LUCIE LANE,FORT PIERCE,FL34946 Phone:772-466-6799 Email:QUICKCALCS@AOL.COM Project • • For: NORMAN STAUB 7847 SABAL LAKE DRIVE,FT.PIERCE,FL Heating Cooling External static pressure 0.08 in H2O 0.08 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.08 in H2O 0.08 in H2O Supply/return available pressure 0.057/0.023 in H2O 0.05710.023 in H2O Lowestfriction rate 0.063 in/100ft 0.063 in/100ft Actual airflow 236 cfm 827 clam Total effective length(TEL) 127 ft SupplyDetail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (Cfm) FR (in) (in) Mat Ln(ft) Ln(ft) Trunk BATH C 698 25 42 0.064 5.0 Ox 0 VIFx 19.7 70.0 M BATH c 557 18 34 0.069 5.0 Ox 0 VIFx 12.8 70.0 M CLOSET" C 4050 55 244 0.069 8.0 Ox 0 VIFx 13.2 70.0 M CLOSET-A c 4050 55 244 0.063 8.0 Ox 0 VIFx 20.9 70.0 MASTER BEDROOM c 4364 83 263 0.068 9.0 Ox 0 VIFx 14.3 70.0 TableReturn Branch Detail Grille Htg Clg TEL Design Veloc Diam HxW Stud/Joist Duct Name Size(in) (Cfm) (Cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb2 Ox 0 236 827 36.1 0.063 774 14.0 Ox 0 VIFx BoldlIralic values have been manually overridden • —Fk wrightsoft- 2020-Mar-1114:15:32 Right-Siite@Universal201919.0.07 RSU08101 Pagel ACCP, ...ICKtDoaments\WrightsoftWAC1STAUB,NORMAN.rup Calc=MJ8 Front Doortaces:SE -�d- wrightsoft° Duct System Summary Date: UNIT#2 By. QUICK CALCS, INC. 317 ST.LUCIE LANE,FORT PIERCE,FL34946 Phom:772466-6799 Email:QUICKCALCS@AOL.COM Project Information For: NORMAN STAUB 7847 SABAL LAKE DRIVE,FT.PIERCE,FL Heating Cooling External static pressure 0.08 in H2O 0.08 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.08 in H2O 0.08 in H2O Supply/return available pressure 0.063/0.017 in H2O 0.063/0.017 in H2O Lowest friction rate 0.034 in/100ft 0.034 in/100ft Actual airflow 1600 cfm 1600 cfm Total effective length(TEL) 237 ft SupplyDetail Table Design Htg CIg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Mat Ln(ft) Ln(ft) Trunk DEN h 7557 369 281 0.034 9.0 0x0 VIFx 75.8 110.0 st5 DINING/LIVING C 5895 160 238 0.050 8.0 Ox 0 VIFx 36.2 90.0 st2 DINING/LIVING-13 c 5895 160 238 0.054 8.0 Ox 0 VIFx 27.8 90.0 st2 DININGILIVING-C c 5895 160 238 0.049 8.0 Ox 0 VIFx 37.9 90.0 st2 KITCHEN c 3655 122 148 0.045 7.0 Ox 0 VIFx 51.6 90.0 st1 LIVING h 5794 283 214 0.034 8.0 Ox 0 VIFx / 73.2 110.0 st5 LIVING-A h 5794 283 214 0.034 8.0 Oxo VIFx 76.6 110.0 st5 POWDER h 1327 65 28 0.046 7.0 Ox 0 VIFx 48.5 90.0 st1 Supoly Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st5 PeakAVF 934 710 0.034 874 14.0 0 x 0 VInIFIx st1 st1 PeakAVF .1121 885 0.034 803 16.0 0 x 0 VInIFIX st2 PeakAVF 479 715 0.049 910 12.0 0 x 0 VInIFIX tableRetu'..rn Branch Detail Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (n) (in) Opening(in) Matl Trunk rb3 Ox 0 1600 1600 50.2 0.034 905 18.0 Ox 0 VIFx Boldrralic values have been manuallyoverridden wrigt�tsofC® 2020-Mar-11 14:15:32 At.. � .4.�u«cw,.H.n„..,gym,.,,, Right-Slue@Universa1201919.0.07RSU08101 Page ICKOoamerts\WdghtsoftHVAC\STAUB,NORMAN.np Calc=MJ8 Frord Door faces:SE Job: 1 wrightsofte, Duct System Summary Date: UNIT#3 By. QUICK CALCS, INC. 317 ST.LUCIE LANE,FORT PIERCE,FL34946 Phone:772466-6799 Email:QUICKCALCS@AOL.COM Project Information For: NORMAN STAUB 7847 SABAL LAKE DRIVE,FT.PIERCE,FL Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.28 in H2O 0.28 in H2O Available static pressure 0.22 in H2O 0.22 in H2O Supply/return available pressure 0.133/0.087 in H2O 0.133/0.087 in H2O Lowest friction rate 0.080 in/100ft 0.080 in/100ft Actual airflow 483 cfm 827 cfm Total effective length(TEL) 204 ft Suppjy Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Mat Ln(ft) Ln(ft) Trunk BATH c 1532 69 69 0.080 6.0 Oxo VIFx 33.5 90.0 st3 BEDROOM2 c 2411 48 109 0.080 7.0 0x0 VIFx 21.9 90.0 st3 BEDROOM 3 c 5970 86 271 0.080 8.0 Ox 0 VIFx 27.6 90.0 st3 C;ST h 1107 28 22 0.080 4.0 Ox 0 VIFx 4.0 70.0 CLOSET h 1527 38 31 0.080 4.0 Ox 0 VIFx 21.9 90.0 st3 OFFICE c 3576 107 162 0.080 7.0 Ox 0 VIFx 24.7 90.0 st4 OFFICE-A c 3576 107 162 0.080 7.0 Ox 0 VIFx 19.1 90.0 st4 Suoply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (Cfm) (cfm) FR (fpm) (in) (in) Material Trunk st4 PeakAVF 215 324 0.080 594 90.0 0 x 0 VinIFIX st3 PeakAVF 241 481 0.080 612 92.0 0 x 0 VInIFIx TableRettith Branch,Detail Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (Cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(n) Matl Trunk rb4 0x0 146 193 68.3 0.127 438 9.0 Ox 0 VIFx rd rb5 Ox 0 203 449 77.4 0.112 824 10.0 Ox 0 VIFx rt1 rb1 Ox 0 135 184 80.1 0.108 338 10.0 Ox 0 VIFx rt1 Boldktalic values have been manually overridden wr!nh 4 ftp 2020-Mar-11 14:15:32 ru>pno-.e.w.,.7�m,�.�y Right-Sule®UNversa1201919.0:07 RSU08101 Page 3 ...ICK\Doamerds\WdghtsoftWAC\STAUB,NORMAN.rup CaIc=MJ8 Front Door faces:SE I Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt1 PeakAVF 483 827 0.108 592 16.0 0 x 0 VinIFIX I i I i I wright30ft" 2020-Mar-11 14:15:32 �'� nU. fn e.i.nuw.yamw� Right-Stite®Universal201919.0.07RSU08101 Page 4 �+� ...ICK�DoameNs\WrightsoftHVAC%STAUB,NORMAN.np Calc=MJ8 Front Door faces:SE