Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutInspection Docs Job:
- - Wrightsofto Project Summary By.
UNIT# 1
QUICK CALCS, INC.
317 ST.LUCIE LANE,FORT PIERCE,FL34946 Phone:772-466-6799 Email:QUICKCALCS@AOL.COM
ProJect Information
For: NORMAN STAUB
7847 SABAL LAKE DRIVE,FT.PIERCE,FL
I
Notes:
Pdsian Information
Weather: Fort Pierce,FL,US
Winter Design Conditions Summer Design Conditions
Outside db 42 °F Outside db 90 'F
Inside db 70 'F Inside db 75 'F
Design TD 28 'F Design TD 15 'F
Daily range M
Relative humidity 50 %
Moisture difference 61 grub
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 11048 Btuh Structure 9889 Btuh
Ducts 2519 Btuh Ducts 3829 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 13567 Btuh Use manufacturer's data n
Rate/swin multiplier 0.95
Infiltration Equipmensensible load 13033 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 1927 Btuh
Ducts 1010 Btuh
Central vent(0 cfm) 0 Btuh
Heating Cooling (none)
Area(ft') 906 906 Equipment latent load 2937 Btuh
Volume(ft') 8154 8154
Airchanges/hour 0.37 0.20 Equipment Total Load(Sen+Lat) 15970 Btuh
Equiv,AVF(cfm) 50 27 Req.total capacity at 0.70 SHR 1.6 ton
Heating Equipment Summary Cooling Equipment Summary
Make Make Carrier
Trade Trade CARRIER
Model Cond 24ACB724AO0310
AHRI ref Coil FV4CNF002L
AHRI ref 10359317
Efficiency 100 EFF Efficiency 13.0 EER,16 SEER
Heating Input 3.8 kW Sensible cooling 17360 Btuh
Heating output 12.947 Btuh Latent cooling 7440 Btuh
Temperature rise `50 °F Total cooling 24800 Btuh
Actual airflow 236 cfm Actual airflow 827 cfm
Airflowfactor 0.017 cfrnBtuh Airflowfactor 0.060 cfm/Btuh
Static pressure 0.08 in H2O Static pressure 0.08 in H2O
Space thermostat Load sensible heat ratio 0.82
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
-F�*- w1r19htsoft� 2020-Mar-1114:15:32
�"•r=^e aw a^- Right-Siite®Uriversa1201919.0.07 RSU08101 Pae 1
ACOA 9
...ICK1Doamerrts\WrightsoftFNAC4STAUB,NORMAN.nq� Calc=MJe Front
Project Summary Date:
- wrightsofte UNIT#2 By.
QUICK CALCS, INC.
317 ST LUCIE LANE,FORT PIERCE,FL34946 Phone:772-466-6799 Email:QUICKCALCS@AOL.COM'
a - o •
For: NORMAN STAUB
7847 SABAL LAKE DRIVE,FT.PIERCE,FL
Notes:
� - •n,,Information
Weather: Fort Pierce,FL,US
Winter Design Conditions Summer Design Conditions
Outside db 42 of Outside db 90 °F
Inside db 70 °F Inside db 75 °F
Design TD 28 °F Design TD 15 °F
Daily range M
Relative humidity 50 %
Moisture difference 61 grAb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 24374 Btuh Structure '27567 Btuh
Ducts 8430 Btuh Ducts 12026 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 32804 Btuh Use manufacturer's data n
Rate/swin multiplier 0.95
Infiltration Equipmenq sensible load 37613 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 1681 Btuh
Ducts 3430 Btuh
Central vent(0 cfm) 0 Btuh
Heating Cooling (none)
Area(ftp 2268 2268 Equipment latent load 5111 Btuh
Volume(fl3) 20412 20412
AirchangesAiour 0.22 0.12 Equipment Total Load(Sen+Lat) 42724 Btuh
Equiv AVF(cfm) 75 40 Req.total capacity at 0.70 SHR 4.5 ton
Heating Equipment Summary Cooling Equipment Summary
Make Lennox Make Lennox
Trade LENNOX Trade LENNOX
Model XP25-048-230-** Cond XP25-048-230**
AHRI ref 5947731 Coil CBX40UHV-048*++TDR
AHRI ref 5947731
Efficiency 9.7 HSPF Efficiency 13.0 EER,20 SEER
Heating Input Sensible cooling 33600 Btuh
Heating output 47500 Btuh @ 47°F Latent cooling 14400 Btuh
Temperature rise 27 °F Total cooling 48000 Btuh
Actual airflow 1600 cfm Actual airflow 1600 cfrn
Airflowfactor 0.049 cfm/Btuh Airflowfactor 0.040 cfm/Btuh
Static pressure 0.08 in H2O Static pressure 0.08 in H2O
Space thermostat Load sensible heat ratio 0.89
Capacity balance point=32°F
p
Backup:
kup:
Input=9 kW, Output=32292 Btuh,100 AFUE
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
-Flawrightsoli t® 2020-Mar-11 14:15:32
Right-Stite®UNversal201919.0.07 RSU08101 Page 2
ACCk ICK1DoaanentslWdghtsoftHVAC1STAUB,NORMAN.np Calc=MJ8 Front Door faces:SE
® Project Summary Date:
- - wrightsoft UNIT O By.
QUICK CALCS, INC.
317 ST.LUCIE LANE,FORT PIERCE,FL34946 Phone:772466-6799 Email:QUICKCALCS@AOL.COM
• • I NMI •
For: NORMAN STAUB
7847 SABAL LAKE DRIVE,FT.PIERCE,FL
Notes:
D&Ign Information
Weather: Fort Pierce,FL,US
Winter Design Conditions Summer Design Conditions
Outside db 42 OF Outside db 90 OF
Inside db 70 OF Inside db 75 OF
Design TD 28 OF Design TD 15 OF
Daily range M
Relative humidity 50 %
Moisture difference 61 grub
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 16308 Btuh Structure 13854 Btuh
Ducts 2981 Btuh Ducts 4397 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 19289 Btuh Use manufacturer's data n
Rate/swin multiplier 0.95
Infiltration Equipmeniq sensible load 17339 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 1712 Btuh
Ducts 1166 Btuh
Central vent(0 cfm) 0 Btuh
Heating' Cooling (none)
Area(ft2) 1209 1209 Equipment latent load 2878 Btuh
Volume(ft) 10881 10881
Airchanges/hour 0.32 0.17 Equipment Total Load(Sen+Lat) 20217 Btuh
Equiv.AVF(cfm) 59 31 Req.total capacity at 0.70 SHR 2.1 ton
Heating Equipment Summary Cooling Equipment Summary
Make Make Carrier
Trade Trade CARRIER
Model Cond 24ACB724AO0310
AHRI ref Coil FV4CNF002L
AHRI ref 10359317
Efficiency 100 EFF Efficiency 13.0 EER,16 SEER
Heating input 7.8 kW Sensible cooling 17360 Btuh
Heating output 26550 Btuh Latent cooling 7440 Btuh
Temperature rise 50 OF Total cooling 24800 Btuh
Actual airflow 483 cfm Actual airflow 827 cfm
Airflowfactor 0.025 cfmBtuh Airflowfactor 0.045 cfm/Btuh
Static pressure 0.50 in H2O Static pressure 0.50 in H2O
Space thermostat Load sensible heat ratio 0.86
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
2020-Mar-11 14:15:32
.� wrightsoTt�
- �� ^-�^^••^•-yv^P� RigM-Sute�l Urtiversa1201919.0.07 RSU08101 Page 3
ICK1Docunents\WrightsoftWAC\STAUB,NORMAN.np Calc=MJ8 Front Door faces:SE
Wrights®ft°
Duct System Summary Date:
UNIT#1 B�
QUICK CALCS, INC.
317 ST.LUCIE LANE,FORT PIERCE,FL34946 Phone:772-466-6799 Email:QUICKCALCS@AOL.COM
Project • •
For: NORMAN STAUB
7847 SABAL LAKE DRIVE,FT.PIERCE,FL
Heating Cooling
External static pressure 0.08 in H2O 0.08 in H2O
Pressure losses 0 in H2O 0 in H2O
Available static pressure 0.08 in H2O 0.08 in H2O
Supply/return available pressure 0.057/0.023 in H2O 0.05710.023 in H2O
Lowestfriction rate 0.063 in/100ft 0.063 in/100ft
Actual airflow 236 cfm 827 clam
Total effective length(TEL) 127 ft
SupplyDetail Table
Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv
Name (Btuh) (cfm) (Cfm) FR (in) (in) Mat Ln(ft) Ln(ft) Trunk
BATH C 698 25 42 0.064 5.0 Ox 0 VIFx 19.7 70.0
M BATH c 557 18 34 0.069 5.0 Ox 0 VIFx 12.8 70.0
M CLOSET" C 4050 55 244 0.069 8.0 Ox 0 VIFx 13.2 70.0
M CLOSET-A c 4050 55 244 0.063 8.0 Ox 0 VIFx 20.9 70.0
MASTER BEDROOM c 4364 83 263 0.068 9.0 Ox 0 VIFx 14.3 70.0
TableReturn Branch Detail
Grille Htg Clg TEL Design Veloc Diam HxW Stud/Joist Duct
Name Size(in) (Cfm) (Cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk
rb2 Ox 0 236 827 36.1 0.063 774 14.0 Ox 0 VIFx
BoldlIralic values have been manually overridden
• —Fk wrightsoft- 2020-Mar-1114:15:32
Right-Siite@Universal201919.0.07 RSU08101 Pagel
ACCP, ...ICKtDoaments\WrightsoftWAC1STAUB,NORMAN.rup Calc=MJ8 Front Doortaces:SE
-�d- wrightsoft°
Duct System Summary Date:
UNIT#2 By.
QUICK CALCS, INC.
317 ST.LUCIE LANE,FORT PIERCE,FL34946 Phom:772466-6799 Email:QUICKCALCS@AOL.COM
Project Information
For: NORMAN STAUB
7847 SABAL LAKE DRIVE,FT.PIERCE,FL
Heating Cooling
External static pressure 0.08 in H2O 0.08 in H2O
Pressure losses 0 in H2O 0 in H2O
Available static pressure 0.08 in H2O 0.08 in H2O
Supply/return available pressure 0.063/0.017 in H2O 0.063/0.017 in H2O
Lowest friction rate 0.034 in/100ft 0.034 in/100ft
Actual airflow 1600 cfm 1600 cfm
Total effective length(TEL) 237 ft
SupplyDetail Table
Design Htg CIg Design Diam H x W Duct Actual Ftg.Egv
Name (Btuh) (cfm) (cfm) FR (in) (in) Mat Ln(ft) Ln(ft) Trunk
DEN h 7557 369 281 0.034 9.0 0x0 VIFx 75.8 110.0 st5
DINING/LIVING C 5895 160 238 0.050 8.0 Ox 0 VIFx 36.2 90.0 st2
DINING/LIVING-13 c 5895 160 238 0.054 8.0 Ox 0 VIFx 27.8 90.0 st2
DININGILIVING-C c 5895 160 238 0.049 8.0 Ox 0 VIFx 37.9 90.0 st2
KITCHEN c 3655 122 148 0.045 7.0 Ox 0 VIFx 51.6 90.0 st1
LIVING h 5794 283 214 0.034 8.0 Ox 0 VIFx / 73.2 110.0 st5
LIVING-A h 5794 283 214 0.034 8.0 Oxo VIFx 76.6 110.0 st5
POWDER h 1327 65 28 0.046 7.0 Ox 0 VIFx 48.5 90.0 st1
Supoly Trunk Detail Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk
st5 PeakAVF 934 710 0.034 874 14.0 0 x 0 VInIFIx st1
st1 PeakAVF .1121 885 0.034 803 16.0 0 x 0 VInIFIX
st2 PeakAVF 479 715 0.049 910 12.0 0 x 0 VInIFIX
tableRetu'..rn Branch Detail
Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size(in) (cfm) (cfm) (ft) FR (fpm) (n) (in) Opening(in) Matl Trunk
rb3 Ox 0 1600 1600 50.2 0.034 905 18.0 Ox 0 VIFx
Boldrralic values have been manuallyoverridden
wrigt�tsofC®
2020-Mar-11 14:15:32
At.. � .4.�u«cw,.H.n„..,gym,.,,, Right-Slue@Universa1201919.0.07RSU08101 Page
ICKOoamerts\WdghtsoftHVAC\STAUB,NORMAN.np Calc=MJ8 Frord Door faces:SE
Job:
1 wrightsofte, Duct System Summary Date:
UNIT#3 By.
QUICK CALCS, INC.
317 ST.LUCIE LANE,FORT PIERCE,FL34946 Phone:772466-6799 Email:QUICKCALCS@AOL.COM
Project Information
For: NORMAN STAUB
7847 SABAL LAKE DRIVE,FT.PIERCE,FL
Heating Cooling
External static pressure 0.50 in H2O 0.50 in H2O
Pressure losses 0.28 in H2O 0.28 in H2O
Available static pressure 0.22 in H2O 0.22 in H2O
Supply/return available pressure 0.133/0.087 in H2O 0.133/0.087 in H2O
Lowest friction rate 0.080 in/100ft 0.080 in/100ft
Actual airflow 483 cfm 827 cfm
Total effective length(TEL) 204 ft
Suppjy Branch Detail Table
Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv
Name (Btuh) (cfm) (cfm) FR (in) (in) Mat Ln(ft) Ln(ft) Trunk
BATH c 1532 69 69 0.080 6.0 Oxo VIFx 33.5 90.0 st3
BEDROOM2 c 2411 48 109 0.080 7.0 0x0 VIFx 21.9 90.0 st3
BEDROOM 3 c 5970 86 271 0.080 8.0 Ox 0 VIFx 27.6 90.0 st3
C;ST h 1107 28 22 0.080 4.0 Ox 0 VIFx 4.0 70.0
CLOSET h 1527 38 31 0.080 4.0 Ox 0 VIFx 21.9 90.0 st3
OFFICE c 3576 107 162 0.080 7.0 Ox 0 VIFx 24.7 90.0 st4
OFFICE-A c 3576 107 162 0.080 7.0 Ox 0 VIFx 19.1 90.0 st4
Suoply Trunk Detail Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (Cfm) (cfm) FR (fpm) (in) (in) Material Trunk
st4 PeakAVF 215 324 0.080 594 90.0 0 x 0 VinIFIX
st3 PeakAVF 241 481 0.080 612 92.0 0 x 0 VInIFIx
TableRettith Branch,Detail
Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size(in) (Cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(n) Matl Trunk
rb4 0x0 146 193 68.3 0.127 438 9.0 Ox 0 VIFx rd
rb5 Ox 0 203 449 77.4 0.112 824 10.0 Ox 0 VIFx rt1
rb1 Ox 0 135 184 80.1 0.108 338 10.0 Ox 0 VIFx rt1
Boldktalic values have been manually overridden
wr!nh 4 ftp
2020-Mar-11 14:15:32
ru>pno-.e.w.,.7�m,�.�y Right-Sule®UNversa1201919.0:07 RSU08101 Page 3
...ICK\Doamerds\WdghtsoftWAC\STAUB,NORMAN.rup CaIc=MJ8 Front Door faces:SE
I
Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk
rt1 PeakAVF 483 827 0.108 592 16.0 0 x 0 VinIFIX
I
i
I
i
I
wright30ft" 2020-Mar-11 14:15:32
�'� nU. fn e.i.nuw.yamw� Right-Stite®Universal201919.0.07RSU08101
Page 4
�+� ...ICK�DoameNs\WrightsoftHVAC%STAUB,NORMAN.np Calc=MJ8 Front Door faces:SE