HomeMy WebLinkAboutProject informationResidential Electric Water Heater
Upright Models
C.E.C. Listed
Model
Capacity
Recovery
A
B
C
D
Approx.
Number
90'F Rise
Floor to
Jacket
Floor to
Floor to
Shipping
Heater
Dia.
Water
TO
Weight
1st Hour
Top
Conn.
Cann.
U.S. Imp.
Rating Energy
U.S. Imp.
Gal. Gal.
(Gal.) Factor
GPH- GPH'
in.
in,
in.
in.
lbs.
RE330S6
30 25
47 0.95
21 18
47
20
473/4
473/4
100
RE340S6
40 33
55 0.95
21 18
471/e
22
485/8
485/a
114
RE340T6
40 33
56 0.95
21 18
605/s
20
1 613/8
1 613/s
125
RE350S6
50 42
67 0.95
21 18
47
24
1 473/4
473/4
144
RE350T6
50 42
67 0.95
21 18
585/8
22
593/e
593/e
138
RE24036t
40 33
55 0.95
21 18
48
20
1 483/4
483/4
123
RE25056t
50 42
67 0.95
21 18
47
22
1 473/4
47V4
143
Model
Capacity
Recovery
50°C Rise
A
Floor to
B
Jacket
C
Floor to
D
Floor to
Approx.
Shipping
Number
Heater
Dia.
Water
TO
Weight
1st Hour
Top
Cann.
Conn.
Rating Energy
Liters/
Liters
(Liters) Factor
Hour'
in
mm.
mm.
mm.
kg.
RE330S6
114
178 0.95
79
1194
508
1213
1213
45
RE340S6
151
208 0.95
79
1216
559
1235
1235
52
RE340T6
151
1 212 0.95
1 79
1540
508
1559
1559
57
RE350S6
189
254 0.95
79
1194
610
1213
1213
65
RE350T6
189
254 0.95
79
1489
559
1508
1508
63
RE240S6t
151
208 0.95
79
1219
508
1238
1238
56
RE250S6t
189
254 0.95
79
1 1194
1 559
1213
1213
65
tModels include supplied insulation blanket (2" thick). Dimensions in charts above do not include blanket thickness.
For 10 year models, change suffix "6" to "10".
'Based on 4500W/4500W, Non -Simultaneous operation.
Energy Factor and First Hour Rating is based on the latest AHRI directory listings.
Wattage
Limitations for
Simultaneous
Operation
Wattage
Voltage Limitations for
Non -Simultaneous
120V 208V 240V 277V 400V Operation
Voltage
120V
yes
208V
yes
240V
yes
277V
yes
480V
yes
150OW / 150OW
yes
yes
yes
yes
yes 150OW / 150OW
2000W / 2000W
no
yes
yes
yes
yes 2000W / 2000W
yes
yes
yes
yes
yes
250OW / 250OW
no
yes
yes
yes
yes 250OW / 250OW
yes
yes
yes
yes
yes
3000W / 3000W
no
yes
yes
yes
yes 3000W / 3000W
yes
yes
yes
yes
yes
350OW/350OW
no
yes
yes
no
no 3500W /350OW
no
es
es
no
no
4000W / 4000W
no
yes
yes
yes
yes 4000W / 4000W
no
yes
yes
yes
yes
450OW / 4500W
no
yes
yes
yes
yes 450OW / 450OW
no
yes
yes
yes
yes
5000W / 5000W
no
yes
yes
yes
yes 5000W / 5000W
no
yes
yes
yes
yes
550OW/550OW
no
no
yes
no
no 550OW /550OW
no
yes
yes
no
no
6000W / 6000W
no
no
no
yes
li yes 6000W / 6000W
I no
yes
yes
yes
yes
Wattage
Recovery A
GPH Temperature Rise "F
60 80 90 100 120
1500W
10
8
7
6
5
2000W
14
10
9
8
7
250OW
17
13
11
10
9
3000W
21
15
14
12
10
3500W
24
18
16
14
12
4000W
28
21
18
16
14
450OW
31
23
21
19
15
5000W
34
26
23
21
17
5500W
38
29
25
23
19
6000W
41
31
28
25
21
♦(GPH based on Non -Simultaneous
operation, when Simultaneous
operation the GPH will
approximately double.)
General:
All models ETL listed. These heaters are wired inter -locking
(Non -Simultaneous, Single Phase) 240V with two 450OW elements, unless otherwise specified.
All water and electrical connections are 3/4" NPT (19mm).
All models certified at 300 psi test pressure (2068 kPa) and 150 psi working pressure (1034 kPa.)
Dimensions and specifications subject to change without notice
in accordance with our policy of continuous product improvement.
BRADFORD WHITE'
W A T E R H E A T E R S
Ambler, PA
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Sales 800-523-2931 • Fax 215-641-1670 / Technical Support 800-334-3393 a Fax 269-795-1089 • Warranty 800-531-2111 s Fax 269-795-1089
International: Telephone 215-641-9400 • Telefax 215-641-9750 / www.bradfordwhite.com
BlraoFORD WHITE-CANADW INC. Sales / Technical Support 866-690-0961 / 905-238-0100 Fax 905-238-0105 / www.bradfordwhite.com
Built to be the BestTM
02015, Bradford White Corporation. All rights reserved.
1201-A-1215 Printed in U.S.A.
PERMIT SUBMITTAL DOCUMENT
BRADFORD WHITE®
W A T E R H E A T E R S
Residential Upright
Electric Water Heater
Photo is of
RE250S6
-��7ww+Wi4w'itMUllgm 1+�eiw�xeu�x� "w"uaw Nw 1
Copper Screw Type Immersion Element
(Incoloy type immersion element available upon request)
The Upright Electric Models Feature:
■ DOE —All residential storage models meet or exceed efficiency
requirements of the Department of Energy, ASHRAE Standard 90.1 b
(current standard) and the National Appliance Energy Conservation Act of
1987 recent amendment effective April 16, 2015, which supercedes all state
and local efficiency requirements.
■ Fully Automatic Controls —Fast -acting surface -mount thermostats for
automatic temperature control. Factory -installed sensitive manual reset
energy cutoff for safety to prevent overheating.
■ Direct Heat Transfer with Immersed Elements —Transfers heat directly
and efficiently to the water. Screw -in style.
■ Factory -Installed Hydrojer Total Performance System —Cold water inlet
sediment reducing device helps prevent sediment build-up in tank. Increases
first hour delivery of hot water while minimizing temperature build-up in tank.
■ Vitraglas® Lining —Bradford White tanks are lined with an exclusively
engineered enamel formula that provides superior tank protection from the
highly corrosive effects of hot water. This formula (Vitraglas®) is fused to the
steel surface by firing at a temperature of over 1600°F (871 °C).
■ Non-CFC Foam Insulation —Covers the sides and top of the tank,
reducing the amount of heat loss. This results in less energy consumption,
improved operation efficiencies, and jacket rigidity.
■ Water Connections— -'V4" NPT factory -installed true dielectric fittings
extend water heater life and ease installation.
■ Factory -Installed Heat Traps —Design incorporates a flexible disk that
reduces heat loss in piping and eliminates the potential for noise
generation.
■ Protective Magnesium Anode Rod —Provides added protection against
corrosion for long trouble -free service.
■ Simultaneous and Non -Simultaneous Operation Available —
Simultaneous operation indicates when both elements (if equipped) are
being heated at the same time. Non -Simultaneous operation indicates when
one element is being heated at a time.
■ Voltages Available— 1 20V, 208V, 240V, 277V, 480V.
■ Single Phase or Three Phase Operation Available— 1 20V & 277V may
only be wired for single phase operation.
■ T&P Relief Valve —Installed.
■ Design evaluated by ETL in accordance with Part 280.707(d) of HUD
Mobile Home Construction and Safety Standards for Energy Efficiency.
it LAIMP
ST-es c 004u66 or 10-YearLimited Tank Warranties/6or 10-YearLimited Warranty on ComponentParts.
sPm For more information on warranty, please visit www.bradfordwhite.com
For products installed in USA, Canada and Puerto Rico. Some states do not allow limitations on warranties. See complete
Intertek Intertelk copy of the warranty included with the heater.
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666: 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485.879; 5,574,822; 7,971,560: 7,992,526;
6,684,821; 6,442,178; 7,334,419; 7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026; 5,341,770; 7,337,517; 7,665,211; 7,665.210; 7,063,132; 7,063,133; 7,559,293; 7,900,589; 5,943,984;
8,082,888; 5,988,117; 7,621,238; 7,650,859; 5,761,379; 7,409,925: 5,277,171; 8,146,772; 7,458,341: 2,262,174. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS:
2,314,845; 2,504,824; 2,108,186; 2,143,031; 2,409,271; 2,548,958: 2,112,515:2,476,685; 2,239,007; 2,092,105; 2,107,012. Vitraglas• and Hydrolet" are registered trademarks of BradfordWhile- Corporation.
PERMIT SUBMITTAL DOCUMENTS 1201-A-1215