HomeMy WebLinkAboutProduct Approval (2) Florida Building Code Online Page 1 of 3
Business & Professional Regulation
Ira1rr
BCIS Home I Log In I User Registration Hot Topics Submit Surcharge ( Stats&Facts Publications Contact Us BCIS Site Map Links i Search
I�
Product Approval
-USER:Public User
L
Product Aooroval Menu>Product or Application Search>Application List>Application Detail
FL# FL17022-R7
Application Type t Revision
Code Version 2017
Application Status Approved
Comments 08/18/2017v.date reapply 08/21/17
Archived ❑
Product Manufacturer Extreme Metal Fabricators,LLC
Address/Phone/Email 2160 SW Poma Drive F�le.1tlLe+ opy
Palm City,FL 34990 .y
(772)872-8034
Flvalidation@yahoo.com
Authorized Signature Richard McKuhen ` �^;�t "{ ED ®�
Flvalidation@yahoo.com�— �`�H C5.'�
C"Or-fiE'C M eNC
Technical Representative Richard MCKuhe b,�j,
Address/Phone/Email 2160 SW Poma'D isle, M130CC -33
C®1 rT Palm.City,FL 34990 �richa 87emfab. �a0?0
richard@emfab.net
Quality Assurance Representative
Address/Phone/Email
.Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed LOCKE BOWDEN
the Evaluation Report
Florida License PE-49704
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Zachary R.Priest,P.E.
® Validation Checklist-Hardcopy Received
Certificate of Independence FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.pdf
Referenced Standard and Year(of Standard) Standard Year
TAS 125 2003
UL 1897 2012
UL 580 2006
Equivalence of Product Standards
Certified By .
Sections from the Code
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQWtDgv2aB QpHpQQ... 3/12/2020
Florida Building Code Online Page 2 of 3
Product Approval Method Method 1 Option D
Date Submitted 08/18/2017
Date Validated 08/25/2017
Date Pending FBC Approval 08/28/2017
Date Approved 10/10/2017
Summary of Products
FL Mo , e ame Description
17022.1 1-"5V Crimp"(R6) 26 Gauge steel,3/8"rib height,24"wide lapped roof panel
mechanically attached to 15/32"plywood or Wood Deck with
fasteners
Limits of Use Installation Instructions
rD oved for use in HVHZ: FL17022 R7 II FL 17022.1 5 V CRIMP ssr.odf
Approve se ou side HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for conditions.Install the FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.Ddf
assembly in compliance with the installation method listed in Created by Independent Third Party:Yes
this report and applicable code sections of FBC. Refer to
manufacturer's.installation instructions.
17022.2 2-"5V Crimp"(116) 0.032"Aluminum,3/8"Rib height,21"wide lapped roof
panel,mechanically attached to 15/32"plywood or Wood
Deck with exposed fasteners
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssr.Ddf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for conditions.InstaII the FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 ALUM ssr.Ddf
assembly in compliance with the installation method listed in Created by Independent Third Party:Yes
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
17022.3 3-"1.5"Mechanical Seam"(115) 1.5"rib height,16"wide,24 gauge steel,standing seam roof
panel mechanically attached to 15/32"plywood or wood deck
with clips and fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 17022.3 1.5 MECHANICAL
Approved for use outside HVHZ:Yes seam 24oa ssr.odf
Impact Resistant:No Verified By: Locke Bowden,P.E.49704
Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes
Other:Refer to evaluation report for conditions and Evaluation Reports
limitations of use.Install the assembly in compliance with the FL17022 R7 AE FL 17022.3 1.5 MECHANICAL
installation method listed in this report and applicable code seam 24oa ssr.Ddf
sections of FBC.Refer to manufacturer's installation Created by Independent Third Party:Yes
instructions.
17022.4 4-"1.5"Mechanical Seam"(R5) 1.5"rib height, 16"wide,0.032"aluminum,standing seam
roof panel mechanically attached to 15/32"plywood or Wood
Deck with clips and fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ_:No FL17022 R7 II FL 17022.4 MECHANCIAL SEAM
Approved for use outside HVHZ:Yes ALUMINUM ssr.odf
Impact Resistant:No Verified By: Locke Bowden,P.E.49704
Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes
Other:Refer to evaluation report for conditions and Evaluation Reports -
limitations of use.Install the assembly in compliance with the FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM
installation method listed in this report and applicable code ALUMINUM ssr.odf
sections of FBC.Refer to manufacturer's installation Created by Independent Third Party:Yes
instructions.
17022.5 5-"1 in. Nail Strip"(RS) 1"rib height,16"wide,26'gauge steel,standing seam roof
panel mechanically attached to 15/32"plywood or wood deck
with fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssr.Ddf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for conditions and FL17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssr.Ddf
limitations of use.Install the assembly in compliance with the Created by Independent Third Party:Yes
installation method listed in this report and applicable code
sections of FBC.Refer to manufacturer's installation
instructions.
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDnv2aBQpHpQQ... 3/12/2020
Florida Building Code Online Page 3 of 3
17022.6 . 6-"1 in. Nail Strip"(115) 1"rib height, 16"wide,0.032"aluminum,standing seam roof
panel mechanically attached to attached to 15/32"plywood or
Wood Deck with fasteners,
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 17022.6 1.0 NAIL STRIP 0.032
Approved for use outside HVHZ:Yes ALUM ssr.pdf
Impact Resistant:No Verified By: Locke Bowden,P.E.49704
Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes
Other:Refer to evaluation report for conditions and Evaluation Reports
limitations of use.Install the assembly in compliance with the FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032
installation method listed in this report and applicable code ALUM ssr.pdf
sections of FBC. Refer to manufacturer's installation Created by Independent Third Party:Yes
instructions.
17022.7 7-"1.5 in. Nail Strip"(115) 1.5"rib height,19"wide,26 gauge steel,standing seam roof
panel mechanically attached to 15/32"plywood or wood deck
with fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 17022.7 1.5 Nail Strio 26GA ssr.pdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant: No Created by Independent Third Party:Yes
Design'Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation.report for conditions and FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr.pdf
limitations of use.Install the assembly in compliance with the Created by Independent Third Party:Yes
installation method listed in this report and applicable code
sections of FBC.Refer to manufacturer's installation
instructions.
17022.8 8-"EMAX Rib"(R5) 29 gauge steel,lapped roof panel mechanically attached to
15/32"plywood or wood deck with exposed fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 177022.8 EMAX Rib ssr.pdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for conditions and FL17022 R7 AE FL 177022.8 EMAX Rib ssr.Ddf
limitations of use.Install the assembly in compliance with the Created by Independent Third Party:Yes
installation method listed in this report and applicable code
sections of FBC. Refer to manufacturer's installation
instructions.
17022.9 9-"PBR MAX"(115) 26 gauge steel,lapped roof panel mechanically attached to
.15/32"plywood or wood deck with exposed fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 17022.9 PBR RIB ssr.pdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure: +N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for conditions and FL17022 R7 AE FL 17022.9 PBR RIB ssr.Ddf
limitations of use.Install the assembly in compliance with the Created by Independent Third Party:Yes
installation method listed in this report and applicable code
sections of FBC.Refer to manufacturer's installation
instructions.
Back Next _
Contact Us::2601 Blair Stone Road,Tallahassee Fl.32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395."Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The
emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please
click here.
Product Approval Accepts: -
Credit Card
'. Safe
https://www.*floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv2aBQpl4pQQ... 3/12/2020
I
1'Product ReportFabricators,
2160 SW Poma Drive
Palm City, FL 34990
1. (772)872-8034_
Florida Product •
Compliant with Florida Building Code 2017 (6th ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec. 1507.4.2
Yield strength: 50 ksi min.; Attached to min. 15/32" plywood or Wood
Deck w/ min.0.42 specific gravity with screws. 24" Coverage
Rib Height 3/8"
Corrosion Resistant Compliant: FBC Sec. 1507.4.3
Fastener 1 (Method 1 Attachment):#9 x 1-1/2" Hex-Washer Head wood screw* to penetrate
3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet
requirements)
Fastener 2 (Method 2,3, &4 Attachment): #10 x 1-1/2" Hex-Washer Head wood screw* to
penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length
to meet requirements)
Underlayment: To be compliant with FBC Sec. Chart 1507.1.1
Slope: Shall be in compliance with FBC Sec. 1507.
S terser attachment specifications above
Install Details: Table A Allowable Loads METHOD METHOD 2 METHOD 3 METHOD 4
DESIGN PRESSURE* 6 PS -93.S PSF -101 PSF -228 PSF
ROW SPACING 16"o.c. 16" o.c. 8"O.C. 6"o.c.
FASTENER SPACING (ALONG Panel width) 12" O.C. 12"o,c.. 12"o.c. 12"o.c.
FASTENER SIZE #9 #10 #10 #10
Reference Data: ARCHITECTURAL TESTING, INC.TST ID#: 1527
UL 580-06& 1897-041 Test Report 1016893.01-450-18 05/02/14
Test Report F3366.01-450-18 12/18/15
TAS 125-03 Test Report D05893.02-450-18 07/22/14
*EQUIVALENCY-UL 1897-04 is equivalent to test standard UL 1897-12 *Design pressure margin of safety 2:1
Locke Bowden,P.E.does not have,not will acquire a financial inyq e �cg ` tigy mfacturing or distributing products
under this evaluation. ° • r' '.
Locke Bowden,P.E.is not owned,operated,or controlled by air coaipar(Vprnbb9&4ture`m,or distributing products under this
report. '
a.
0
10 N A l
I
FL17022.1 5V Crimp (26GA Steel), 24" Wide Roof Panel - Details
Limitations:
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed.
2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D
4. Engineering analysis for"project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. >
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for
Structural Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
Fasteners-
119 x 1-112" in. or
#10 x 1-112"Min.perTWO A'(or Row 5-V Crimp Roof Panel
Spacing and Design Pressures
Hex Washer Head Wood Screws
.0m v�
Deck:
15/32"or greater Plywood,or
Wood plank
14-
12"
318"
OPT[ONAL STRIATIONS
Panel Profile
Nominal 12" Nominal 12"
O.C. D.C.
Fasten
9_x1-1/2"Min. or #10 x 1-1/2"Min.per
Table"A" Hex Washer Head Screw
Panel Spaced 12"o.c.across the Panel Width
Refer to Table"A"for Spacing Along Panel
Overlap Length
Deck-15/32"or greater
Plywood,or
-Wood plank