Loading...
HomeMy WebLinkAbout05100330 FROM :Construction Team D G FRX NO. :772 429 0742 &'''~-u~:~.. ~VI- .u1WpeCt10a )Jttermalt. Woods Apartments Ma~. 25 2006 02:06PM Pi t:I~C~/I/~O , NAY 2 5 , þ 200, 8t. ~ ~bl¡c ~ e/. C O"Ir. . 01.1,., ~"- T ðday~' .D.q: 7 To: Stat Via Fax: One· P.. r o tal Mario FuglJene, GF A International 772-489":2;89 C~; Sen t Via F.~: Oue Page Total Building .Inspections, St. Lucie County Bldg Dep1 772-462..61,~43 Requelf.tæd Dltê of Jnspe~tion: . ~ /4.. 7 . J~_ I Req..~ted Time of Inspection: 0 lr: B1IUdml # / {,' ~ L '7 ,PIJ"IDJt~ -7f(6 ()~/~J-' 03'2-1 4/,( O~/O- ò ~ 30 Insp~dloÞ Typ.,: 4f- /£ II! eo/UÞ1YJS ..¡-Te · V?fI¡tt, ,1!tcl fltXV'e'Arl ,S"/J~, ~'O f, 3rJ AOy-o &d' ~;~dt'~ 'q r AD.DITJONAL COMMENTS: aMI' J~ . '7 '-"'M (1 tt:....Y '2 () ~ 7....) -,) ~~" -----..- ", - ~ -, -- "''Y'' .. v. ,.,,..112 p...... '4 U I_ J~Jtterma. Woods Apartment! Today" ,Date: r· ~~ ~ To: StDt Vi. lax: Ooe· Pt.. "fotal /þ~ ' ",;':' C l!5lp " A/4Y2<j' E:lj 1:J}/:-, 200? J BuildinslnspcctJoW1, St. LU~le County BidS Dept . / 772462-<H43 ,,~/ Marlo FUi '-1ene, GF 4.1\ International 772...489~2 9g9 ee: .Seat Via 'a~: ODe Pag~ Total -,., - Reque~ted Datt of InsplCtloa: Reqaefted Time otInspection: , . BqjJdjJr.8 # ,Pørm1tN -=It t6 OS-/O -Ö3).ßJ . -7 051t>- 03g0 . Insp~1io.. Type: :=# /~. I(y' (JÚW1ílf Ý. /2~" '¡;e~ f.&Þ¡ 2/Jd -Aðr tu~t/d ~. I .. '~"I7 decf ~r(~~/4~f(otf cI~ ~íf >;J~~ · III sk-rl' )7,') /r' :3 r?/ ~Oy'~, ~JI@d :5 d f.... AD,DITlONAL COMMENTS: . -4ff3:Z, ~~ lY..tIJ 1f ~ !d WdSÞ:~Ø 9ØØ~ Þ~ ·new ~ÞLØ 6~Þ ~LL: ·ON X~~ 8 a wedl UOJ+8n~+SUOJ: wo~~ FROM :Construction Team D G FAX NO. :772 429 0742 Atðq~t~~~1; '¡Qr ,inSpect1a11 J~jttermaft Woods Apartments Ma~. 23 2006 02:51PM Pi Today! .Oate: 5-' MAY 2 3 2007 To: StDt Via Fax: Ouc' p". TQtal Mario Fuguene, OFA Intcn1a.tional 772..489-2~89 Public Works St. Lucie Counh, F~ .:7, ~ C~: Sent Via Fa~~ Oue Page Total BuildinslnspcctiOM; St. Lucie County Bldg Dep1 772462-6..t43 v - - 51l-~ j()'1 (2 : 3 {) , , / £ * !"7~ -=II' /6 OS/ô -'0 3?-1,:1{;"7 0..,/0 -03'30 ~,k" II? C()/()~f).f' + /i~'·J7i:e. ¡feQf¥l IrI ¡'/oar eas't S"ljJ~ Inspecfio. Type: 13fJyif/ '1 /q2- þu.:,¡:, s-I~JI-e.1 rðo¡; deci· tJ-e>-f" 5' ¡ rJe, - , ".Ill _¢'hðl"¡'f)Jc 2t)cÁ"ff~Y""' f1-o'1- s' ..-de.. AD.DJTIONAL COMMENTS: , R.qU~'ied Date of Inspection: Requ.-ted Time r>t Inspection: B1IjJdizr.g # ,Permit ~ c, 1-·-'20k4~·'J '2- 7882 SW Ellipse Wdy Stuart, Florida. 34997 Phone:~72)489~989 Fax: ~72) 489-2989 TRANSMITTAL Project: Kitterman Woods Site St. Lucie From: Darœe M. Pilarski for Mario C. Fuquene, PE Project No.: 04-0357 A Date: May 30, 2007 We are Sending you: Originals Date Description 2 Various Signed and Sealed Inspection Reports for Building No. 17, Report # 2 - 6 .........-..............-.......-....................-....................... .-.-.................-..............-....-......-.. .....-.............-...........-...............-.-.-..........-.........-................................-...................-.....................-....................................-.............................. ............................................................................-................................ ............ ..... 2 Various Signed and Sealed Shoring & Re-shoring Certifications for Building No. 17, 2nd floor slab, 1st floor walls for the east half pour (05121/07), 3rd floor deck, ~ floor walls, west half pour (05122107), 3rd floor deck steel, 2m floor walls, east half pour (05123/07), roof deck steel, 3rd floor walls, west half pour (05124/07), roof deck steel, 3rd floor walls, east half pour (05/25/07). .... ....... ..-.-..... ......... -.. ..-.... -.... ... ... ..... ...... ..-. ...... ... . ..... ........... ... ... .... ............ ..... .... ....... ... ....-............. ... ........... ........ ... ........ .... ....... ...- ..... ...... ....... -... ... .... ...... ... .-. ............ ... ..-.. ..-.. .... .-.... ..... .-...... .... ..... ... .... ..-.... .... ... ......... ..................... ...... ..... ........ ... ..-........ .. ..... . ...... ..... ......... ........ ....... .. ........ .... ......................... ........-.. Distribution The Construction Team and Development Corporation St. Lucie County Building Department To: Attention: Mr. Robin Van Werkhoven Attention: Mr. Ken Arnold .....-....-......-......................--.......-...-..... ..-.......--..................-....-.........-.-....-.-.-.-...-....--......-......-......-.............-.............-..... ...........-........................................... ......-................--......................-.-......-.-.................. .............-.............-......................................-....................... ............-.......... .-.... ........... ...... 901 Northpoint Parkway # 108 2300 Virginia Avenue Address West Palm Beach, FL 33407 (Mail via USPS - Original) Fort Pierce, Florida 34982 (Hand Deliver - Original) Hand Delivered on 05/30/07 May 21, 2007 Mr. Robin Van Werkhoven The Construction Team and Development Group Corporation 901 Northpoint Parkway, Suite 108 West Palm Beach, FL 33407 RE: Kitterman Woods Site Building No. 17 (Permit SLC-051 0-0330) Shoring and Re-Shoring Certification GFA Project No.:04-0357A Dear Mr. Van Werkhoven: Pursuant to your request, LM Engineering, Inc. d/b/a GFA International (GFA) performed an inspection of the shoring and re-shoring system at building No, 17 on May 21, 2007 for the 2nd floor slab, 1st floor walls, east half pour, Based on the inspection, GFA certifies that the shoring and re-shoring installation has been placed in accordance with the shoring and re-shoring drawings prepared by CES Consulting Group, Please call if you have any questions, Sincerely, LM Engineering, Inc. d/b/a GFA International C;1rj:O . 05121/07 M1 ·L r' F P - arlu v. uq e e, .1:.. Branch Manager STATE ()F FLORIDA Registered Professional Engineer Number: 60583 Environmental Geotechnical Private Provider, Services Construction Materials Testing Threshold and Special Inspections Corporate Office 442 N.W 35th Street Boca Raton, FL 33431 (561) 347-0070 (561) 347 0809 Fax Gulf Coast Office 5851 Country Lakes Dr. Fort Myers, FL 33905 (239) 489-2443 (239) 489-3438 Fax Treasure Coast Office 7882 S.W. Ellipse Way Stuart, FL 34997 (772) 489-9989 (772) 489-2989 Fax Orlando Office 9659 Tradeport Dr, Orlando, FL 32827 (407) 447-9865 (407) 447-9868 Fax The First Coast 5971 Powers Ave. Suite 5 Jacksonville, Florida 32217 (904) 854-9900 (904) 854-9901 Fax 7882 S.W. Ellipse Way · Stuart, FL 34997 · (772) 489-9989 International REINFORCING STEEL INSPECTION REPORT GFA PROJECT #04-0357A DATE 5/21/07 PROJECT Kitterman Woods 7209-7255 Woods Island Circle lOCATION (Building 17) DAY PERMIT NO. SLC-051 0-0330 BRIGHT SUN CLEAR OVERCAST RAIN OWNER Kitterman Woods WEATHER X BELOW 60 60-75 75-90 ABOVE 90 CONTRACTOR Construction T earn TEMPERATURE X LOW MODERATE HIGH Report No ARCHITECT Stephano DuLuca & Asso WIND X LOW t~ODERATE HIGH 2 ENGINEER CES Consulting HUMIDITY X MEMBERS/AREA INSPECTED: ORe-Inspection Building No. 17, 2nd floor slab (116), 1st floor walls, shorinQ and reshoring (111) for east 1/2 of building. THE FOllOWING HAVE BEEN INSPECTED FOR COMPLIANCE WITH THE APPROVED CONTRACT DOCUMENTS AND ACCEPTED PRACTICES. COMPLIES YES NO N/A X X X X X X X X X X X X X X 1 SOIL BEARING CAPACITY 2 BUILDING LOCATION 3 BUILDING SLAB ELEVATION 4 TERMITE TREATMENT VERIFIED 5 COMPACTION TESTING 6 FORMING DIMENSIONS 7 INSIDE OF FORMS CLEAN 8 WIRE MESH REINFORCING SIZE AND LAP 9 REBAR GRADE, SIZE, SPACING, QUANTITY, SHAPE, TYING 10 SPLICES 11 REBAR CLEAN AND FREE OF OIL 12 REBAR CLEARANCE FROM FORMS AND EARTH 13 EMBEDS/ANCHOR BOLTS IN PLACE AND SECURED 14 SHORING AND RE-SHORING 15 POST TENSIONED CABLE LAYOUT AND PROFILE X DISPOSITION OF INSPECTION: Œ]section / Area Approved DWork In Progress D Re-Inspecticn Reqú;red COMMENTS I ACTION REQUIRED: Total Hours: 2 Inspection Performed By: James Lydl')P.. B~~ 15'11 Inspection Certified By: Mario C. Fuquene, P,E. Registered Professional No: P.E. # 60583 Certified Special Inspector No: FBPE Certificate No: 4930 ENV\RONMENTAL · GEOTECHNICAL · MATERIALS TESTING · THRESHOLD & SPECIAL INSPECTIONS OFFICES THROUGHOUT FLORIDA May 22, 2007 Mr. Robin Van Werkhoven The Construction Team and Development Group Corporation 901 Northpoint Parkway, Suite 1 08 West Palm Beach, FL 33407 RE: Kitterman Woods Site Building No. 17 (Permit SLC-051 0-0330) Shoring and Re-Shoring Certification GFA Project No.:04-0357 A Dear Mr. Van Werkhoven: Pursuant to your request, LM Engineering, Inc. d/b/a GFA International (GFA) performed an inspection of the shoring and re-shoring system at building No, 17 on May 22, 2007 for the 3rd floor deck steel, 2nd floor walls, west half pour. Based on the inspection, GFA certifies that the shoring and re-shoring installation has been placed in accordance with the shoring and re-shoring drawings prepared by CES Consulting G ro up. Please call if you have any questions. Sincerely, LMEngineering~ Inc. d/b/a GFA International CA# 49:30 }v1 ~ --::}:::r-> OS/22/07 MaridC. FuqJen~, P.E. Branch Manager STATE OF FLORIDA Registered Professional Engineer Number: 60583 Environmental Geotechnical Private Provider, Services Construction Materials Testing Threshold and Special Inspections Corporate Office 442 N.W 35th Street Boca Raton, FL 33431 (561) 347-0070 (561) 347 0809 Fax Gulf Coast Office 5851 Country Lakes Dr. Fort Myers, FL 33905 (239) 489-2443 (239) 489-3438 Fax Treasure Coast Office 7882 S,W Ellipse Way Stuart, FL 34997 (772) 489-9989 (772) 489-2989 Fax Orlando Office 9659 Tradeport Dr. Orlando, FL 32827 (407) 447-9865 (407) 447-9868 Fax The First Coast 5971 Powers Ave, Suite 5 Jacksonville, Florida 32217 C904) 854-9900 (904) 854-9901 Fax 7882 S.W. Ellipse Way · Stuart, FL 34997 · (772) 489-9989 International REINFORCING STEEL INSPECTION REPORT GFA PROJECT #04-0357A DATE 5/22/07 PROJECT Kitterman Woods 7209-7255 Woods Island Circle LOCATION (Building 17) DAY PERMIT NO. SL C-051 0-0330 BRIGHT SUN CLEAR OVERCAST RAIN OWNER Kitterman Woods WEATHER X BELOW 60 60-75 75-90 ABOVE 90 CONTRACTOR Construction T earn TEMPERATURE X LOW MODERATE HIGH ARCHITECT Stephano DuLuca & Asso WIND X Report No LOW MODERATE HIGH 3 ENGINEER CES Consulting HUMIDITY X MEMBERS/AREA INSPECTED: DRe-lnspection Building No. 17, 3rd floor deck steel ( 192), 2nd floor walls, shoring and reshoring ( 111) for west 1/2 of building. THE FOLLOWING HAVE BEEN INSPECTED FOR COMPLIANCE WITH THE APPROVED CONTRACT DOCUMENTS AND ACCEPTED PRACTICES. COMPLIES YES NO N/A X X X X X X X X X X X X X X 1 SOIL BEARING CAPACITY 2 BUILDING LOCATION 3 BUILDING SLAB ELEVATION 4 TERMITE TREATMENT VERIFIED 5 COMPACTION TESTING 6 FORMING DIMENSIONS 7 INSIDE OF FORMS CLEAN 8 WIRE MESH REINFORCING SIZE AND LAP 9 REBAR GRADE, SIZE, SPACING, QUANTITY, SHAPE, TYING 10 SPLICES 11 REBAR CLEAN AND FREE OF OIL 12 REBAR CLEARANCE FROM FORMS AND EARTH 13 EMBEDS/ANCHOR BOLTS IN PLACE AND SECURED 14 SHORING AND RE-SHORING 15 POST TENSIONED CABLE LAYOUT AND PROFILE X DISPOSITION OF INSPECTION: 0Section I Area Approved DWOrk In Progress D Re-!nspectil)h f~equjred COMMENTS I ACTION REQUIRED: Total Hours: Inspection Performed By: Ja-mes Lydon~ ~~J5'i 1 ¡(J/Jor--::: Inspection Certified By: Mario C ':Yquene, P.E. -q;;;;; Registered Professional No: P.E. # 60583 Certified Special Inspector No: FBPE Certificate No: 4930 ENVIRONMENTAL · GEOTECHNICAL · MATERIALS TESTING · THRESHOLD & SPECIAL INSPECTIONS OFFICES THROUGHOUT FLORIDA May 23, 2007 Mr. Robin Van Werkhoven The Construction Team and Development Group Corporation 901 Northpoint Parkway, Suite 1 08 West Palm Beach, FL 33407 RE: Kitterman Woods Site Building No. 17 (Permit SLC-051 0-0330) Shoring and Re-Shoring Certification GFA Project No.:04-0357 A Dear Mr. Van Werkhoven: Pursuant to your request, LM Engineering, Inc. d/b/a GFA International (GFA) performed an inspection of the shoring and re-shoring system at building No, 17 on May 23, 2007 for the 3rd floor deck steel, 2nd floor walls, east half pour, Based on the inspection, GFA certifies that the shoring and re-shoring installation has been placed in accordance with the shoring and re-shoring drawings prepared by CES Consulting Group. Please call if you have any questions, Sincerely, LM Engineering, Inc. d/b/a GFA International CA# 4930 (~'j ~~ \. .~..:- <. OS/23/07 Mario . FUqÙe~ Branct, Manager STArTE OF FLORIDA Registered Professional Engineer Number: 60583 Environmental Geotechnical Private Provider, Services Construction Materials Testing Threshold and Special Inspections Corporate Office 442 N.W 35th Street Boca Raton, FL 33431 (561) 347-0070 (561) 347 0809 Fax Gulf Coast Office 5851 Country Lakes Dr, Fort Myers, FL 33905 (239) 489-2443 (239) 489-3438 Fax Treasure Coast Office 7882 S.W, Ellipse Way Stuart, FL 34997 (772) 489-9989 (772) 489-2989 Fax Orlando Office 9659 Tradeport Dr. Orlando, FL 32827 (407) 447-9865 (407) 447-9868 Fax The First Coast 5971 Powers Ave, Suite 5 Jacksonville, Florida 32217 (904) 854-9900 (904) 854-9901 Fax 7882 S.W. Ellipse Way · Stuart, FL 34997 · (772) 489-9989 International REINFORCING STEEL INSPECTION REPORT GFA PROJECT #04-0357A DATE 5/23/07 PROJECT Kitterman Woods 7209-7255 Woods Island Circle LOCATION (Building 17) DAY PERMIT NO. SL C-051 0-0330 BRIGHT SUN CLEAR OVERCAST RAIN OWNER Kitterman Woods WEATHER X BELOW 60 60-75 75-90 ABOVE 90 CONTRACTOR Construction T earn TEMPERATURE X LOW MODERATE HIGH Report No ARCHITECT Stephano DuLuca & Asso WIND X LOW MODERATE HIGH 4 ENGINEER CES Consulting HUMIDITY X MEMBERS/AREA INSPECTED: DRe-lnspection Building No. 17, 3rd floor deck steel (192), 2nd floor walls, shoring and reshoring (111) for east 1/2 of building. THE FOLLOWING HAVE BEEN INSPECTED FOR COMPLIANCE WITH THE APPROVED CONTRACT DOCUMENTS AND ACCEPTED PRACTICES. COMPLIES YES NO N/A X X X X X X X X X X X X X X 1 SOIL BEARING CAPACITY 2 BUILDING LOCATION 3 BUILDING SLAB ELEVATION 4 TERMITE TREATMENT VERIFIED 5 COMPACTION TESTING 6 FORMING DIMENSIONS 7 INSIDE OF FORMS CLEAN 8 WIRE MESH REINFORCING SIZE AND LAP 9 REBAR GRADE, SIZE, SPACING, QUANTITY, SHAPE, TYING 10 SPLICES 11 REBAR CLEAN AND FREE OF OIL 12 REBAR CLEARANCE FROM FORMS AND EARTH 13 EMBEDS/ANCHOR BOLTS IN PLACE AND SECURED 14 SHORING AND RE-SHORING 15 POST TENSIONED CABLE LAYOUT AND PROFILE X DISPOSITION OF INSPECTION: 0section I Area Approved DWork In Progress D Re-Inspection Required COMMENTS I ACTION REQUIRED: Total Hours: Inspection Performed By: James Lydon, BN 1511 Inspection Certified By: Mario C. Fuquene, P.E. Registered Professional No: P.E. # 60583 Certified Special Inspector No: FBPE Certificate No: 4930 ENVIRONMENTAL · GEOTECHNICAL · MATERIALS TESTING · THRESHOLD & SPECIAL INSPECTIONS OFFICES THROUGHOUT FLORIDA May 24, 2007 Mr. Robin Van Werkhoven The Construction Team and Development Group Corporation 901 Northpoint Parkway, Suite 108 West Palm Beach, FL 33407 RE: Kitterman Woods Site Building No. 17 (Permit SLC-051 0-0330) Shoring and Re-Shoring Certification GFA Project No.:04-0357A Dear Mr. Van Werkhoven: Pursuant to your requ~st, LM Engineering, Inc. d/b/a GFA International (GFA) performed an inspection of the shoring and re-shoring system at building No, 17 on May 24, 2007 for the roof deck steel, 3rd floor walls, west half pour. Based on the inspection, GFA certifies that the shoring and re-shoring installation has been placed in accordance with the shoring and re-shoring drawings prepared by CES Consulting Group. Please call if you have any questions, Sincerely, LM Engineering, Inc. d/b/a GFA International CA# 4930 ~)1 .. .' OS/24/07 f\.1ario r--Fuque 6r Branch Manager ST.t\TE OF FLORIDA Registered Professional Engineer Number: 60583 Environmental Geotechnical Private Provider, Services Construction Materials Testing Threshold and Special Inspections Corporate Office 442 N,W 35th Street Boca Raton, FE 33431 (561) 347-0070 (561) 347 0809 Fax Gulf Coast Office 5851 Country Lakes Dr. Fort Myers, FL 33905 (239) 489-2443 (239) 489-3438 Fax Treasure Coast Office 7882 S,W Ellipse Way Stuart, FL 34997 (772) 489-9989 (772) 489-2989 Fax Orlando Office 9659 Tradeport Dr, Orlando, FL 32827 (407) 447-9865 (407) 447-9868 Fax The First Coast 5971 Powers Ave. Suite 5 Jacksonville, Florida 32217 (904) 854-9900 (904) 854-9901 Fax I 7882 S.W. Ellipse Way · Stuart, FL 34997 · (772) 489-9989 International REINFORCING STEEL INSPECTION REPORT GFA PROJECT #04-0357A DATE 5/24/07 PROJECT Kitterman Woods 7209-7255 Woods Island Circle lOCATION (Building 17) DAY PERMIT NO. SLC-051 0-0330 BRIGHT SUN CLEAR OVERCAST RAIN OWNER Kitterman Woods WEATHER X BELOW 60 60-75 75-90 ABOVE 90 CONTRACTOR Construction Team I TEMPERATURE X LOW MODERATE HIGH Report No ARCHITECT Stephano DuLuca & Asso WIND X LOW MODERATE HIGH 5 ENGINEER CES Consulting HUMIDITY X MEMBERS/AREA INSPECTED: DRe-lnspection Building No. 17, roof deck steel ( 192), 3rd floor walls, shoring and reshoring (111) for west 1/2 of building. THE FOllOWING HAVE BEEN INSPECTED FOR COMPLIANCE WITH THE APPROVED CONTRACT DOCUMENTS AND ACCEPTED PRACTICES. COMPLIES YES NO N/A X X X X X X X x X X X X X X 1 SOIL BEARING CAPACITY 2 BUILDING LOCATION 3 BUILDING SLAB ELEVATION 4 TERMITE TREATMENT VERIFIED 5 COMPACTION TESTING 6 FORMING DIMENSIONS 7 INSIDE OF FORMS CLEAN 8 WIRE MESH REINFORCING SIZE AND LAP 9 REBAR GRADE, SIZE, SPACING, QUANTITY, SHAPE, TYING 10 SPLICES 11 REBAR CLEAN AND FREE OF OIL 12 REBAR CLEARANCE FROM FORMS AND EARTH 13 EMBEDS/ANCHOR BOLTS IN PLACE AND SECURED 14 SHORING AND RE-SHORING 15 POST TENSIONED CABLE LAYOUT AND PROFILE X DISPOSITION OF INSPECTION: 0section I Area Approved DWOrk In Progress D Re-Inspection Required COMMENTS I ACTION REQUIRED: Total Hours : Inspection Periormed By: James Lydon, BN 15~1 1')1,:_: Inspection Certified By: Mario C. Fuquene-,~. E. ' 5!~4/07 Registered Professional No: P.E. # 60583 Certified Special Inspector No: FBPE Certificate No: 4930 ENVIRONMENTAL · GEOTECHNICAL · MATERIALS TESTING · THRESHOLD & SPECIAL INSPECTIONS OFFICES THROUGHOUT FLORIDA May 25, 2007 Mr. Robin Van Werkhoven The Construction Team and Development Group Corporation 901 Northpoint Parkway, Suite 1 08 West Palm Beach, FL 33407 RE: Kitterman Woods Site Building No. 17 (Permit SLC-051 0-0330) Shoring and Re-Shoring Certification GFA Project No.:04-0357 A Dear Mr. Van Werkhoven: Pursuant to your request, LM Engineering, Inc. d/b/a GFA International (GFA) performed an inspection of the shoring and re-shoring system at building No. 17 on May 25, 2007 for the roof deck steel, 3rd floor walls, east half pour. Based on the inspection, GFA certifies that the shoring and re-shoring installation has been placed in accordance with the shoring and re-shoring drawings prepared by CES Consulting Group, Please call if you have any questions. Sincerely, LM Engjneering,~ Inc.. d/b/a GFA International CA# 4930 0VJ ~. . \ --=- - ,{ ::1--05/25/07 Mario G. Fuquené, þ,E. Branctl Manager STATE OF FLORID)),. Registered Professional Engineer Number: 60583 Environmental Geotechnical Private Provider, Services Construction Materials Testing Threshold and Special Inspections Corporate Office 442 N.W 35th Street Boca Raton, FL 33431 (561) 347-0070 (561) 347 0809 Fax Gulf Coast Office 5851 Country Lakes Dr. Fort Myers, FL 33905 (239) 489-2443 (239) 489-3438 Fax Treasure Coast Office 7882 S.W. Ellipse Way Stuart, FL 34997 (772) 489-9989 (772) 489-2989 Fax . Orlando Office 9659 Tradeport Dr. Orlando, FL 32827 (407) 447-9865 (407) 447-9868 Fax The First Coast I 5971 Powers Ave, Suite 5 Jacksonville, Florida 32217 (904) 854-9900 (904) 854-9901 Fax 7882 S.W. Ellipse Way · Stuart, FL 34997 · (772) 489-9989 International REINFORCING STEEL INSPECTION REPORT GFA PROJECT #04-0357A DATE 5/25/07 PROJECT Kitterman Woods 7209-7255 Woods Island Circle LOCATION (Building 17) DAY PERMIT NO. SL C-051 0-0330 BRIGHT SUN CLEAR OVERCAST RAIN OWNER Kitterman Woods WEATHER X BELOW 60 60-75 75-90 ABOVE 90 CONTRACTOR Construction T earn TEMPERATURE X LOW MODERATE HIGH Report No ARCHITECT Stepha no DuLuca & Asso WIND X LOW MODERATE HIGH 6 ENGINEER CES Consulting HUMIDITY X MEMBERS/AREA INSPECTED: DRe-lnspection Building No. 17, roof deck steel ( 1 92}, 3rd floor walls, shoring and reshoring ( 111 ) for east 1/2 of building. THE FOLLOWING HAVE BEEN INSPECTED FOR COMPLIANCE WITH THE APPROVED CONTRACT DOCUMENTS AND ACCEPTED PRACTICES. COMPLIES YES NO N/A X X X X X X X X X X X X X X 1 SOIL BEARING CAPACITY 2 BUILDING LOCATION 3 BUILDING SLAB ELEVATION 4 TERMITE TREATMENT VERIFIED 5 COMPACTION TESTING 6 FORMING DIMENSIONS 7 INSIDE OF FORMS CLEAN 8 WIRE MESH REINFORCING SIZE AND LAP 9 REBAR GRADE, SIZE, SPACING, QUANTITY, SHAPE, TYING 10 SPLICES 11 REBAR CLEAN AND FREE OF OIL 12 REBAR CLEARANCE FROM FORMS AND EARTH 13 EMBEDS/ANCHOR BOLTS IN PLACE AND SECURED 14 SHORING AND RE-SHORING 15 POST TENSIONED CABLE LAYOUT AND PROFILE X DISPOSITION OF INSPECTION: 0section / Area Approved DWOrk In Progress DRe-lnsPeCtion Requìred COMMENTS I ACTION REQUIRED: Total Hours: Inspection Periormed By: Jame5 Lydon, Br\j 1511 Inspection Certified By: Mario C._F~'quene, P .:..E. Registered Professional No: P.E. # 605ti3 Certified Special Inspector No: FBPE Certificate No: 4930 ENVIRONMENTAL · GEOTECHNICAL · MATERIALS TESTING · THRESHOLD & SPECIAL INSPECTIONS OFFICES THROUGHOUT FLORIDA 7882 SW Ellipse Way Stuart, Florida 34997 Phone:~72)489~989 Fax: ~72) 489-2989 TRANSMITrAL Project: Kitterman Woods Site St. Lucie From: Darcee M. Pilarski for Mario C. Fuquene, PE Project No.: 04-0357 A Date: May 22, 2007 We are Sending you: Originals Date Description 2 Various Signed and Sealed Inspection Reports for Building No. 17, Report # 1 ........................................................................................................-............................................-.........................-.......................................-.......-..................-.............-..........-...-...........................--........................-.-..............................................................-......................................................................................... 2 Various Signed and Sealed Shoring & Re-shoring Certifications for Building No. 17, 2nd floor slab, 1 st floor walls for the west half pour (05/18/07). ..................................................................................................................................................................................................................................-.............-............................-..............................................................-.................................................................................................................................................................... Distribution The Construction Team and St. Lucie County Building Development Corporation To: Department Attention: Mr. Robin Van Attention: Mr. Ken Arnold Werkhoven ..................-.........................-....-.-.......-. ...-....-.--.-....---..-. -.........-.-......-.-.-....................-...-..........-.-...-.-.......--.-..........-.. ..........-.....-...-.......---.......................-......-.-........................................--....-.--..-........ ....-................................-..........-...........................-............................................................. 901 Northpoint Parkway # 2300 Virginia Avenue 108 Address West Palm Beach, FL 33407 Fort Pierce, Florida 34982 (Mail via USPS - Original) (Hand Deliver - Original) Hand Delivered on OS/22/07 May 18, 2007 Mr. Robin Van Werkhoven The Construction Team and Development Group Corporation 901 Northpoint Parkway, Suite 108 West Palm Beach, FL 33407 RE: Kitterman Woods Site Building No. 17 (Permit SLC-051 0-0330) Shoring and Re~Shoring Certification GFA Project No.:04-0357A Dear Mr. Van Werkhoven: Pursuant to your request, LM Engineering, Inc. d/b/a GFA International (GFA) performed an inspection of the shoring and re-shoring system at building No, 17 on May 18, 2007 for the 2nd floor' slab, 1st floor walls, west half pour. Based on the inspection, GFA certifies that the shoring and re-shoring installation has been placed in accordance with the shoring and re-shoring drawings prepared by CES Consulting Group. Please call if )/QU ha~ve any questions. Sincerely, LM Engineering, Inc. d/b/a GFA International ~ 30 --05/18/07 .E. Mario C. Fuqua Branch Manager STATE OF FLORIDA Registered Professional Engineer Number: 60583 Environmental Geotechnical Private Provider, Services Construction Materials Testing Threshold and Special Inspections Corporate Office 442 N.W 35th Street Boca Raton, FL 33431 (561) 347-0970 (561) 347 0809 Fax Gulf Coast Office 5851 Country Lakes Dr, Fort Myers, FL 33905 (239) 489-2443 (239) 489-3438- Fax Treasure Coast Office 7882 S,W, Ellipse Way Stuart, FL 34997 (772) 489-9989 (772) 489-2989 Fax Orlando Office 9659 Tradeport Dr, Orlando, FL 32827 (407) 447-9865 (407) 447-9868 Fax The First Coast I 5971 Powers Ave. Suite 5 Jacksonville, Florida 32217 (904) 854-9900 (904) 854-9901 Fax 7881 S.W. Ellipse Way · Stuart, FL 34997 · (772) 489-9989 International REINFORCING STEEL INSPECTION REPORT GFA PROJECT #04-0357A DATE 5/18/07 PROJECT Kitterman Woods 7209-7255 Woods Island Circle LOCATION (Building 17) DAY PERMIT NO. SLC-051 0-0330 BRIGHT SUN CLEAR OVERCAST RAIN OWNER Kitterman Woods WEATHER X BELOW 60 60-75 75-90 ABOVE 90 CONTRACTOR Construction Team TEMPERATURE X LOW MODERATE HIGH Report No ARCHITECT Stepha no DuLuca & Asso WIND X LOW MODERATE HIGH ENGINEER CES Consulting HUMIDITY X MEMBERS/AREA INSPECTED: D Re-Inspection Building No. 17, 2nd floor slab ( 116), 1 st floor walls, shorin9 and reshoring ( 111) for west 1/2 of building. THE FOLLOWING HAVE BEEN INSPECTED FOR COMPLIANCE WITH THE APPROVED CONTRACT DOCUMENTS AND ACCEPTED PRACTICES. COMPLIES YES NO N/A X X X X X X X X X X X X X X 1 SOIL BEARING CAPACITY 2 BUILDING LOCATION 3 BUILDING SLAB ELEVATION 4 TERMITE TREATMENT VERIFIED 5 COMPACTION TESTING 6 FORMING DIMENSIONS 7 INSIDE OF FORMS CLEAN 8 WIRE MESH REINFORCING SIZE AND LAP 9 REBAR GRADE, SIZE, SPACING, QUANTITY, SHAPE, TYING 10 SPLICES 11 REBAR CLEAN AND FREE OF OIL 12 REBAR CLEARANCE FROM FORMS AND EARTH 13 EMBEDS/ANCHOR BOLTS IN PLACE AND SECURED 14 SHORING AND RE-SHORING 15 POST TENSIONED CABLE LAYOUT AND PROFILE X DISPOSITION OF INSPECTION: Œ]section / Area Approved DWOrk In Progress D Re-Inspection Required COMMENTS I ACTION REQUIRED: ......-.~~~---- Total Hours : 2 Inspection Performed By: James Lydon, ~N 1511 Inspection Certified By: Mario C. Fuquene, P.E. Registered Professional No: P. E. # 60583 Certified Special Inspector No: FBPE Certificate No: 4930 ENVIRONMENTAL · GEOTECHNICAL · MATERIALS TESTING · THRESHOLD & SPECIAL INSPECTIONS OFFICES THROUGHOUT FLORIDA FROM :Construction Team D G FAX NO. :772 429 0742 ""'''1( ~~~, ¡VI- ,I.JJf:fpeCt10n }~jtterJbalP: Woods ,Apartments Ma~. 17 2006 02:23PM Pi Today! ,Date: To: SeDe Vi. lax: On~' Pt.. Total lVIario FU8uenc, GFA International 772·489-2~~89 cc: Sent Via F.;~ O1ae P.p Total Building lnsp::ctioI1.1, St. Lucie County Bldg Dep1; 772462.61,143 . ~ , Reque1Ited Date of Inspection: Rtqu~ted Time of mspectioø: B1I1Jdbtg.l# " . I '7 I /~. ~ /5', i ,'erm1tN 'Æ/{{o#7S~, ðSlð -,. 63~f? #/6 {)S/O- () 3'4.7 ' Inspecffon Type: ~/c(;,*/~' (I ¡ Gr'¡lJ~J'Jj' .,- I ~C; f.'e:. ' ea~'4t1 ~7 (1S I,() - 0 ] J~JJ "~/6 ¿.,. ") 2nd '/foðr -et.1~f 5 ,cAe ~ _ "-(1 , JAOIf"1 ^J .} J"l " oOV"" ~ g-' $' /d e , ,'" ADDlnONAL CO~NTS: ,,If l7 If 19;L t>e-c_,I:-, S~~-e."r 1...l1 T,llo6Y" v,~~~l S'o¡e/-e, 5~ 61" 2JJÀ-~ 4s.3'Â... Ardaman & Associates, Inc. 460 NW Concourse Place, Unit #1 Port St. lucie, Florida 34986 (772) 878-0072 ß1"ì:i =# 05/0 -033C) RECEIVED MAY 1 0 2007 FIELD DENSITY REPORT Public Works St. Lucie County, FL DATE OF TEST: 4/30/07 FILE NO.: 06-5586 PROJECT: Kitterman Woods SUBMITTED TO: The Construction Team & Development Group REPORT NO.: FD-235 (MAXIMUM DENSITY DETERMINED IN ACCORDANCE WITH ASTM D-1557/AASHTO T-180) (FIELD DENSITY DETERMINED IN ACCORDANCE WITH ASTM D-2922/AASHTO T-238) Building Pad # 17 Subgrade FS 5' Northwest of Southeast Corner 13.0 111.0 8.4 109.5 100 95 o to -1' 2 20' Northwest of Southeast Corner 13.0 111.0 9.0 108.5 99 95 o to -1' 3 5' Southeast of Northwest Corner 13.0 111.0 9.4 105.1 96 95 o to -1' 4 25' Southeast of Northwest Corner 13.0 111.0 9.2 104.9 95 95 o to -1' 5 1 0' Southwest of Northeast Corner 13.0 111.0 8.1 108.3 98 95 o to -1 ' 6 20' Southwest of Northeast Corner 13.0 111 .0 9.8 106.2 97 95 o to -1' 7 1 0' Northeast of Southwest Corner 13.0 111.0 9.6 1 07.4 98 95 o to -1 ' 8 25' Northeast of Southwest corner 13.0 111.0 9.5 104.9 95 95 o to -1 ' 9 East Center of Pad 13.0 111.0 9.8 105.1 96 95 o to -1 ' 10 West Center of Pad 13.0 111.0 8.2 105.5 96 95 o to -1 ' F-soil directly below subgrade; FS-soil under floor slab; GA-soil in general compacted area; PAV-soil below stabilized section; PSSG-stabilized subgrade; NSSG-non stabilized subgrade; PB-pavement base; NG-natural ground; TOP-top of pipe; BOP-bottom of pipe; TOS - top of structure Da~vJ. r lIacP.E. Br~nch .anag~r FL ~eg. No. q3911 " ../ '\...~- ---- AS MUTUAL PROTECTION TO OUR CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL, 7882 SW Ellipse Way Stuart, Florida 34997 Phone:~72)489~989 Fax: ~72) 489-2989 TRANSMITTAL Project: Kitterman Woods Site St. Lucie From: Darœe M. Pilarski for Mario C. Fuquene, PE Project No.: 04-0357 A Date: June 4, 2007 We are Sending you: Originals Date Description 2 Various Signed and Sealed Inspection Report for Building No, 17, Report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istribution The Construction Team and Development Corporation St. Lucie County Building Department To: Attention: Mr. Robin Van Werkhoven Attention: Mr. Ken Arnold ",. ......, ........... ... ........ ..,...."..."...,.. ....,." .... ......... ...... ,..-.... ,...." ,.........., ............... ..... ... ........... .-............, ,........., ......, ,....,.., .... ...... ........,. .. ......,. ........, '.., '...,.., ....." .... ,.......,.".."" ..., "......... ....... ,...."", ... '. ,..,........, ..." ..........., ...., '..,.. " , ...." '.,.., '.'" ,. ......,........,..,..".., ,....,.. ,..,..." """,..,.,..,.., ,.....""", ",..." ..' ..", .. . .. "",. ,.." . . , ." "",." ,. 901 Northpoint Parkway # 108 2300 Virginia Avenue Address West Palm Beach, FL 33407 (Mail via USPS - Original) Fort Pierce, Florida 34982 (Hand Deliver - Original) Hand Delivered on 06104/07 7882 S.W. Ellipse Way · Stuart, FL 34997 · (772) 489-9989 International Field Report REINFORCED MASONRY INSPECTION REPORT GF A PROJECT # 04-0357 A DATE 6/1/07 PROJECT Kitterman Woods 7209 - 7255 Woods Island Circle (Building LOCATION 17) DAY PERMIT NO. SL C-051 0-0330 BRIGHT SUN CLEAR OVERCAST RAIN OWNER KMJ Apartments WEATHER X BELOW 60 60-75 75-90 ABOVE 90 CONTRACTOR The Construction Team TEMPERATURE X LOW MODERATE HIGH Report No ARCHITECT Stefano De Luca wd Associates WIND X LOW MODERATE HIGH 7 ENGINEER CES Consulting Group HUMIDITY X MEMBERS/AREA INSPECTED: of building. Building # 17, 1 st floor fill cell columns (118) and bond beam (128) for west half THE FOLLOWING HAVE BEEN INSPECTED FOR COMPLIANCE WITH THE APPROVED CONTRACT DOCUMENTS AND ACCEPTED PRACTICES. COMPLIES YES NO X X X X X X N/A X 1 BLOCKS AND MORTAR MIX PROPERLY STORED AND PROTECTED 2 BLOCK TYPE AND SIZE 3 CLEAN-OUT AT 8 FEET OF WALL HEIGHT 4 WEEP HOLES AT EVERY 4 FEET OF WALL HEIGHT 5 FILL CELLS CLEAR 6 MORTAR TYPE AND CONSISTENCY 7 MORTAR TEST 8 MORTAR BED AND HEAD JOINTS 9 HORIZONTAL REINFORCEMENT LAP, SIZE, AND TYPE 10 ANCHORAGE INTO WALLS AND COLUMNS 11 EXPANSION JOINT SIZE AND LOCATION 12 EXPANSION JOINT FILLER MATERIAL 13 WALL BRACING 14 PRISM TEST 15 POST FILLED CELL INSPECTION PERFORMED X X X X X X X X Disposition of inspection ~Section I Area Approved c=JWork In Progress D Re-Inspection DRe-lnspection Required COMMENTS I ACTION REQUIRED: Total Hours : 3 Inspection Performed By: Jim J. Lydon, BN# 1511 Inspection Certifiød By:. Mario C. Fuquene, P. E. Registered Professional No: P. E. # 60583 Certified Special Inspector No: FBPE Certificate No: 4930 ENVIRONMENTAL · GEOTECHNICAL · MATERIALS TESTING · THRESHOLD & SPECIAL INSPECTIONS OFFICES THROUGHOUT FLORIDA FROM :Construction Team D G FAX NO. :772 429 0742 ...~a't ~ E;~'" .I. V I 11....œJ PIC;; tl 0 II IJttennalt WOOd8 Apartments Today) ,Date: b To: SCDt Vi. Fax: One' p~. Tobl Mario FtlS t.œnc. OF ,,4\ Intemational 772,,489-2~89 ee: .. Sen t Vi. F.x: Olle r"ge Total Building Inspectioo.1, St. Lucie County Bldg Dcp1 772-462 461~43 8111JdJ£1 '# R'qge~:ted Date or IDtJpe~tion: Req.ened Time otbtspection:, .P'rmit ill Inspeetio8 Typt: I I åtIl_ AD,DITlONAL COMMENTS: Jun. 01 2006 01:31PM P1 d ¡&IÞI · . lIS.. ~ 1¿J,:r~ oJL ~~ - 56 ¡- ~O:L -'fSS ~ 1f 7882 SW Ellipse Wdy Stuart, Florida 34997 Phone:~72)489~989 Fax: ~72) 489-2989 TRANSMITTAL Project: Kitterman Woods Site St. Lucie From: Darœe M. Pilarski for Mario C. Fuquene, PE Project No.: 04-0357 A Date: June 8,2007 We are Sending you: Originals Date Description 2 Various Signed and Sealed Inspection Report for Building No. 17, Report # 8 - 13 -....................--................................-.........-...................-..........-.-......................................................--......-.........................-............-..-......................-............-...............................-.......-.............................-.....-.............................-....................................................................................-....................................... .-.--.............-............-....-...-.............-.-......-.............-..........-...-...-..........-.-........-......--.......-..-...........-......-....................-.........-.........-........--........-......-................-......-..--..-..........-..................-....-...-....-......-......................................--..........-.....-.....................-...................-....-.................................. Distribution The Construction Team and St. Lucie County Building Development Corporation To: Department Attention: Mr. Robin Van Attention: Mr. Ken Arnold Werkhoven -.......--.-....-..............-..---....-.-.....-.. .-.......-.-.......-.--..-.-..-....-....-.-......-.-.-.--........--...-.----.-.--.-.........-....--.. -.-.-....-....--......-..........-.......-......-..-...-.-.-.................................-...........--.--.......... -......-...-..........-...-.--.......-.-....-..................................................-....-........................... 901 Northpoint Parkway # 2300 Virginia Avenue 108 Address West Palm Beach, FL 33407 Fort Pierce, Florida 34982 (Mail via USPS - Original) (Hand Deliver - Original) Hand Delivered on 06111/07 7882 'S.W. Ellipse Way · Stuart, FL 34997 · (772) 489-9989 International GF A PROJECT # 04-0357 A PROJECT LOCATION REINFORCING STEEL INSPECTION REPORT DATE 6/4/07 Kitterman Woods 720Q-7255 Woods Island Circle (Building 17) DAY PERMIT NO. SLC-051 0-0330 BRIGHT SUN CLEAR OVERCAST RAIN WEATHER X BELOW 60 60-75 75-90 ABOVE 90 TEMPERATURE X LOW MODERATE HIGH Report No WIND X LOW MODERATE HIGH 8 HUMIDITY X ORe-Inspection OWNER Kitterman Woods CONTRACTOR Construction Team ARCHITECT Stephano DuLuca & Asso ENGINEER CES Consulting MEMBERS/AREA INSPECTED: Building No. 17, 1st to 2nd floor stair (123), (4 sets). THE FOLLOWING HAVE BEEN INSPECTED FOR COMPLIANCE WITH THE APPROVED CONTRACT DOCUMENTS AND ACCEPTED PRACTICES. COMPLIES YES NO N/A X X X X X X X X X X X X 1 SOIL BEARING CAPACITY 2 BUILDING LOCATION 3 BUILDING SLAB ELEVATION 4 TERMITE TREATMENT VERIFIED 5 COMPACTION TESTING 6 FORMING DIMENSIONS 7 INSIDE OF FORMS CLEAN 8 WIRE MESH REINFORCING SIZE AND LAP Q REBAR GRADE, SIZE, SPACING, QUANTITY, SHAPE, TYING 10 SPLICES 11 REBAR CLEAN AND FREE OF OIL 12 REBAR CLEARANCE FROM FORMS AND EARTH 13 EMBEDS/ANCHOR BOLTS IN PLACE AND SECURED 14 SHORING AND RE-SHORING 15 POST TENSIONED CABLE LAYOUT AND PROFILE X X X DISPOSITION OF INSPECTION: 0section I Area Approved DWOrk In Progress D Re-Inspection Required COMMENTS / ACTION REQUIRED: Total Hours : Inspection Peñormed By: James Lydon, BN 1511 Inspection Certified By: Mario C. Fuquene, P. E_. Registered Professional No: P. E. # 60583 Certified Special Inspector No: FBPE Certificate No: 4Q30 0~~ ¿1607 ENVIRONMENTAL · GEOTECHNICAL · MATERIALS TESTING · THRESHOLD & SPECIAL INSPECTiONS OFFICES THROUGHOUT FLORIDA I 7882 S.W. Ellipse Way · Stuart, FL 34997 · (772) 489-9989 International Field Report GF A PROJECT # 04-0357 A PROJECT LOCATION PERMIT NO. OWNER REINFORCED MASONRY INSPECTION REPORT DATE 6/4/07 Kitterman Woods 7209 - 7255 Woods Island Circle (Building 17) DAY SLC-051 0-0330 KMJ Apartments BRIGHT SUN CLEAR OVERCAST RAIN WEATHER X BELOW 60 60-75 75-90 ABOVE 90 TEMPERATURE X LOW MODERATE HIGH Report No WIND X LOW MODERATE HIGH 9 HUMIDITY X CONTRACTOR The Construction Team Stefano De Luca wd Associates ARCHITECT ENGINEER CES Consulting Group MEMBERS/AREA INSPECTED: of building. Building # 17, 1 st floor fill cell columns (118) and bond beam (128) for east half THE FOLLOWING HAVE BEEN INSPECTED FOR COMPLIANCE WITH THE APPROVED CONTRACT DOCUMENTS AND ACCEPTED PRACTICES. COMPLIES YES NO X X X X X X N/A X 1 BLOCKS AND MORTAR MIX PROPERLY STORED AND PROTECTED 2 BLOCK TYPE AND SIZE 3 CLEAN-OUT AT 8 FEET OF WALL HEIGHT 4 WEEP HOLES AT EVERY 4 FEET OF WALL HEIGHT 5 FILL CELLS CLEAR 6 MORTAR TYPE AND CONSISTENCY 7 MORTAR TEST 8 MORTAR BED AND HEAD JOINTS 9 HORIZONTAL REINFORCEMENT LAP, SIZE, AND TYPE 10 ANCHORAGE INTO WALLS AND COLUMNS 11 EXPANSION JOINT SIZE AND LOCATION 12 EXPANSION JOINT FILLER MATERIAL 13 WALL BRACING 14 PRISM TEST 15 POST FILLED CELL INSPECTION PERFORMED X X X X X X X X Disposition of inspection ~Section I Area Approved ~Work In Progress E3 Re-Inspection Re-Inspection Required COMMENTS I ACTION REQUIRED: ..-.....-------.-- Total Hours : Inspection Performed By: Jim J. Lydon, BN# '51~+--ÝÌ-:_~ Inspection Certified By: Mario C. Fuquener P..~. . 6/tYOI Registered Professional No: P.E. # 60583 Certified Special Inspector No: FBPE Certificate No: 4930 3 ENVIRONMENTAL · GEOTECHNICAL · MATERIALS TESTING · THRESHOLD & SPECIAL INSPECTIONS OFFICES THROUGHOUT FLORIDA · 7882 S.W. Ellipse Way· Stuart, FL 34997 · (772) 489-9989 International Field Report REINFORCED MASONRY INSPECTION REPORT GF A PROJECT # 04-0357 A DATE 6/5/07 PROJECT Kitterman Woods 7209 - 7255 Woods Island Circle (Building LOCATION 17) DAY PERMIT NO. SL C-051 0-0330 BRIGHT SUN CLEAR OVERCAST RAIN OWNER KMJ Apartments WEATHER X BELOW 60 60-75 75-90 ABOVE 90 CONTRACTOR The Construction Team TEMPERATURE X LOW MODERATE HIGH Report No ARCHITECT Stefano De Luca wd Associates WIND X LOW MODERATE HIGH 10 ENGINEER CES Consulting Group HUMIDITY X MEMBERS/AREA INSPECTED: of building. Building # 17, 2nd floor fill cell columns (118) and bond beam (128) for west half THE FOLLOWING HAVE BEEN INSPECTED FOR COMPLIANCE WITH THE APPROVED CONTRACT DOCUMENTS AND ACCEPTED PRACTICES. COMPLIES YES NO x X X X x X N/A X 1 BLOCKS AND MORTAR MIX PROPERLY STORED AND PROTECTED 2 BLOCK TYPE AND SIZE 3 CLEAN-OUT AT 8 FEET OF WALL HEIGHT 4 WEEP HOLES AT EVERY 4 FEET OF WALL HEIGHT 5 FILL CELLS CLEAR 6 MORTAR TYPE AND CONSISTENCY 7 MORTAR TEST 8 MORTAR BED AND HEAD JOINTS 9 HORIZONTAL REINFORCEMENT LAP, SIZE, AND TYPE 10 ANCHORAGE INTO WALLS AND COLUMNS 11 EXPANSION JOINT SIZE AND LOCATION 12 EXPANSION JOINT FILLER MATERIAL 13 WALL BRACING 14 PRISM TEST 15 POST FILLED CELL INSPECTION PERFORMED X X X X X X X X Disposition of inspection ~Section I Area Approved c==JWork In Progress D Re-Inspection ORe-Inspection Required COMMENTS I ACTION REQUIRED: .0:--- Total Hours : Inspection Performed By: Jim J. Lydon, BN# 1511 1I~2 ~ , , 1 Inspection Certified By: Mario C. Fuquene, P.E. 1 ~ 07 Registered Professional No: P.E. # 60583 Certified Special Inspector No: FBPE Certificate No: 4930 3 ENVIRONMENTAL · GEOTECHNICAL · MAT'ERIALS TESTING · THRESHOLD & SPECIAL INSPECTIONS OFFICES THROUGHOUT FLORIDA 7882 S.W. Ellipse Way · Stuart, FL 34997 · (772) 489-9989 International Field Report REINFORCED MASONRY INSPECTION REPORT GF A PROJECT # 04-0357 A DATE 6/6/07 PROJECT Kitterman Woods 720g - 7255 Woods Island Circle (Building LOCATION 17) DAY PERMIT NO. SLC-051 0-0330 BRIGHT SUN CLEAR OVERCAST RAIN OWNER KMJ Apartments WEATHER X BELOW 60 60-75 75-90 ABOVE 90 CONTRACTOR The Construction Team TEMPERATURE XI LOW MODERATE HIGH Report No ARCHITECT Stefano De Luca wd Associates WIND X LOW MODERATE HIGH 11 ENGINEER CES Consulting Group HUMIDITY X MEMBERS/AREA INSPECTED: of building. Building # 17, 2nd floor fill cell columns (118) and bond beam (128) for east half THE FOLLOWING HAVE BEEN INSPECTED FOR COMPLIANCE WITH THE APPROVED CONTRACT DOCUMENTS AND ACCEPTED PRACTICES. COMPLIES YES NO X X X X X X N/A X 1 BLOCKS AND MORTAR MIX PROPERLY STORED AND PROTECTED 2 BLOCK TYPE AND SIZE 3 CLEAN-OUT AT 8 FEET OF WALL HEIGHT 4 WEEP HOLES AT EVERY 4 FEET OF WALL HEIGHT 5 FILL CELLS CLEAR 6 MORTAR" TYPE AND CONSISTENCY 7 MORTAR TEST 8 MORTAR BED AND HEAD JOINTS g HORIZONTAL REINFORCEMENT LAP, SIZE, AND TYPE 10 ANCHORAGE INTO WALLS AND COLUMNS 11 EXPANSION JOINT SIZE AND LOCATION 12 EXPANSION JOINT FILLER MATERIAL 13 WALL BRACING 14 PRISM TEST 15 POST FILLED CELL INSPECTION PERFORMED X X X x X X X X Disposition of inspection ~Section I Area Approved r:==JWork In Progress BRe-lnspection Re-Inspection Required COMMENTS I ACTION REQUIRED: Total Hours: Inspection Periormed By:oo:~m J. Lydon, BN# 1511 Inspection Certified By: Mario C. Fuquene, P.E. Registered Professional No: P.E. # 60583 Certified Special Inspector No: FBPE Certificate No: 4g30 3 ENVIRONMENTAL · GEOTECHNICAL · MATERIALS TESTING · THRESHOLD & SPECIAL INSPECTIONS OFFICES THROUGHOUT FLORIDA Field Report International . 7882 S.W. Ellipse Way · Stuart, FL 34997 · (772) 489-9989 GF A PROJECT # 04-0357 A REINFORCED MASONRY INSPECTION REPORT PROJECT Kitterman Woods 7209 - 7255 Woods Island Circle (Building 17) DATE 6/7/07 LOCATION DAY PERMIT NO. SLC-051 0-0330 OWNER KMJ Apartments BRIGHT SUN CLEAR OVERCAST RAIN WEATHER X BELOW 60 60-75 75-90 ABOVE 90 TEMPERATURE X LOW MODERATE HIGH Report No WIND X LOW ' MODERATE HIGH 12 HUMIDITY X CONTRACTOR The Construction T earn ARCHITECT Stefano De Luea wd Associates ENGINEER CES Consulting Group MEMBERS/AREA INSPECTED: of building. Building # 17, 3rd floor fill cell columns (118) and bond beam (128) for west half THE FOllOWING HAVE BEEN INSPECTED FOR COMPLIANCE WITH THE APPROVED CONTRACT DOCUMENTS AND ACCEPTED PRACTICES. COMPLIES YES NO N/A X X X X 1 BLOCKS AND MORTAR MIX PROPERLY STORED AND PROTECTED 2 BLOCK TYPE AND SIZE 3 CLEAN-OUT AT 8 FEET OF WALL HEIGHT 4 WEEP HOLES AT EVERY 4 FEET OF WALL HEIGHT 5 FILL CELLS CLEAR 6 MORTAR TYPE AND CONSISTENCY 7 MORTAR TEST 8 MORTAR BED AND HEAD JOINTS 9 HORIZONTAL REINFORCEMENT LAP, SIZE, AND TYPE 10 ANCHORAGE INTO WALLS AND COLUMNS 11 EXPANSION JOINT SIZE AND LOCATION 12 EXPANSION JOINT FILLER MATERIAL 13 WALL BRACING 14 PRISM TEST 15 POST FILLED CELL INSPECTION PERFORMED X X X X X X X X X X X Disposition of inspection Œ]Section I Area Approved L.:.:.:JWork In Progress E3 Re-Inspeetion Re-Inspeetion Required COMMENTS I ACTION REQUIRED: Total Hours: 2 Inspection Performed By: Jim J. Lydon, B~# 1511 Inspection Certified By: Mario C. Fuquene, P.E. Registered Professional No: P.E. # 60583 Certified Special Inspector No: FBPE Certificate No: 4930 ENVIRONMENTAL · GEOTECHNICAL · MATERIALS TESTING · THRESHOLD & SPECIAL INSPECTIONS OFFICES THROUGHOUT FLORIDA Field Report International 7å82 S.W, Ellipse Way · Stuart, FL 34997 · (772) 489-9989 REINFORCED MASONRY INSPECTION REPORT GFA PROJECT # 04-0357A DATE 6/8/07 LOCATION Kitterman Woods 720g - 7255 Woods Island Circle (Building 17) DAY PROJECT PERMIT NO. SLC-051 0-0330 ENGINEER CES Consulting Group BRIGHT SUN CLEAR OVERCAST RAIN WEATHER X BELOW 60 60-75 75-90 ABOVE 90 TEMPERATURE X LOW MODERATE HIGH Report No WIND X LOW MODERATE HIGH 13 HUMIDITY X OWNER KMJ Apartments CONTRACTOR The Construction Team ARCHITECT Stefano De Luca wd Associates MEMBERS/AREA INSPECTED: of build i ng. Building # 17, 3rd floor fill cell columns (118) and bond beam (128) for east half THE FOLLOWING HAVE BEEN INSPECTED FOR COMPLIANCE WITH THE APPROVED CONTRACT DOCUMENTS AND ACCEPTED PRACTICES. COMPLIES YES NO N/A X X X X 1 BLOCKS AND MORTAR MIX PROPERLY STORED AND PROTECTED 2 BLOCK TYPE AND SIZE 3 CLEAN-OUT AT 8 FEET OF WALL HEIGHT 4 WEEP HOLES AT EVERY 4 FEET OF WALL HEIGHT 5 FILL CELLS CLEAR 6 MORTAR TYPE AND CONSISTENCY 7 MORTAR TEST 8 MORTAR BED AND HEAD JOINTS g HORIZONTAL REINFORCEMENT LAP, SIZE, AND TYPE 10 ANCHORAGE INTO WALLS AND COLUMNS 11 EXPANSION JOINT SIZE AND LOCATION 12 EXPANSION JOINT FILLER MATERIAL 13 WALL BRACING 14 PRISM TEST 15 POST FILLED CELL INSPECTION PERFORMED X X X X X X X X X X X Disposition of inspection Œ]Section I Area Approved c==JWork In Progress D Re-Inspection DRe-lnspection Required COMMENTS I ACTION REQUIRED: Total Hours: 3 Inspection Performed By: Jim J. Lydon, BN#. 15·11 11/;/_ Inspection Certified By: Mario C. Fuquene, P.E. ~07 Registered Professional No: P.E. # 60583 Certified Special Inspector No: FBPE Certificate No: 4g30 ENVIRONMENTAL · GEOTECHNICAL · MATERIALS TESTING · THRESHOLD & SPECIAL INSPECTIONS OFFICES THROUGHOUT FLORIDA 7882 SW Ellipse Way Stuart, Florida 34997 Phone:~72)489~989 Fax: ~72) 489-2989 Project: Kitterman Woods Site St. Lucie TRANSMITTAL From: Darcee M. Pilarski for Mario C. Fuquene, PE Project No.: 04-0357 A Date: June 20,2007 We are Sending you: Originals Date Description 2 06/14/07 Signed and Sealed Inspection Report for Building No. 17, Report # 14 "......, ...", ,..", ,..." '..., ......., ...'.... .....",..,.....",..,.., ,.. ..... "..,.." ,..,...., ........,.. ......., ......, .......,..".. ...., ............. ...... ....-...... ..........., ,..,..., ,....,.., ..., ,...... ,., ................., ......... ,......" ,.,.., ....... ,..... ........... ..." ,.,..", ..,.... ..... ,...... ... '., ....., ,..... ,.... ... '.'" ,..""".. ....., .." , ,'.., ,..........",."", .."", ,...."".."....,... .... '" ...." ,. eo,. ,.""....""..". ., " ., , ,." " ., , "" '" '" "" . ., ..........."..".., ,....... '..., ....... .........,..., ....." ,. ,.." ,....., '.., ,......, ,...,.. ......" ..., .......... .., .......,.......,.. . .......... ....... .............. ..... ......,...., .......,.. .... ......., .....,.. ...... ........,..,..,......" .....,..,.".., ............................. '.. ........ '.'.., ........,.. ,.. ,.................... ,...",....." ,.,....",... ,...." ,."..,....." ..,.., ,.".. ..",.."", ...... ,..,..,.. ".."".." ,... """, ,...", "'," .."", , ,.." , ,...., ",.. Distribution To: The Construction Team and Development Corporation St. Lucie County Building Department Attention: Mr. Robin Van W erkhoven Attention: Mr. Ken Arnold ,... .... ..... ,............. ......... ,........... .......... ......, . ...., ........ ............ '...., ............ ,....., ............, ............ ......................... ........ ........ ,...... .. ....... ..... .... .. ,... .... ....., ..,............. ............... ..,...... ....., .......... ........... .......... ...... ,. .........,.., ......................,..., ...., ........... .................... ....., ..... ....., .., .......... ..... .................. ......, ... .... ............ ,......... .... ............ 901 Northpoint Parkway # 108 2300 Virginia Avenue Address West Palm Beach, FL 33407 (Mail via USPS - Original) Fort Pierce, Florida 34982 (Hand Deliver - Original) Hand Delivered on 06120107 7882 S.W. Ellipse Way · Stuart, FL 34997 · (772) 489-9989 International GFA PROJECT #04-0357A PROJECT LOCATION REINFORCING STEEL INSPECTION REPORT Kitterman Woods 7209-7255 Woods Island Circle (Building 17) DATE 6/14/07 PERMIT NO. SLC-051 0-0330 DAY BRIGHT SUN CLEAR OVERCAST RAIN WEATHER X BELOW 60 60-75 75-90 ABOVE 90 TEMPERATURE X LOW MODERATE HIGH WIND X Report No LOW MODERATE HIGH 14 HUMIDITY X ORe-Inspection OWNER Kitterman Woods CONTRACTOR Construction T earn ARCHITECT Stephano DuLuca & Asso ENGINEER CES Consulting MEMBERS/AREA INSPECTED: Building No. 17, 2nd to 3rd floor stair (123} for front of building, (2 sets). THE FOLLOWING HAVE BEEN INSPECTED FOR COMPLIANCE WITH THE APPROVED CONTRACT DOCUMENTS AND ACCEPTED PRACTICES. COMPLIES YES NO N/A X X X X X X X X X X X X 1 SOIL BEARING CAPACITY 2 BUILDING LOCATION 3 BUILDING SLAB ELEVATION 4 TERMITE TREATMENT VERIFIED 5 COMPACTION TESTING 6 FORMING DIMENSIONS 7 INSIDE OF FORMS CLEAN 8 WIRE MESH REINFORCING SIZE AND LAP 9 REBAR GRADE, SIZE, SPACING, QUANTITY, SHAPE, TYING 10 SPLICES 11 REBAR CLEAN AND FREE OF OIL 12 REBAR CLEARANCE FROM FORMS AND EARTH 13 EMBEDS/ANCHOR BOLTS IN PLACE AND SECURED 14 SHORING AND RE-SHORING 15 POST TENSIONED CABLE LAYOUT AND PROFILE X X X DISPOSITION OF INSPECTION: Œ]section / Area Approved DWOrk In Progress DRe-lnSPEtCtion Required COMMENTS / ACTION REQUIRED: Total Hours: Inspection Performed B},: Jarnes J. Lydon, !3N i511 ~ ~ Inspection Certified By: Mario_C. FUQueoe, P.E. 6/18/ô7 Registered Professional No: P.E. # 60583 Certified Special Inspector No: FBPE Certificate No: 4930 2 ENVIRONMENTAL · GEOTECHNICAL · MATERIALS TESTING · THRESHOLD & SPECIAL INSPECTIONS OFFICES THROUGHOUT FLORIDA