Loading...
HomeMy WebLinkAboutProduct Approval 10/30/2019 Florida Building Code Online Business 1 1nal Regulatio BCS Home I Log in I User Reytapauo'n I Hot To ics I Submit Surcharge I Stats&Faft I PuWlcadihr I '06 i;]- BCIS Site Map I this .Scarth I Rnoduet Approval USER PubU.U. RECEIVED Product Approval Menu>Product or ApplleationSearch>Aoolication List>Application Detall FL* FL18355-R4 MAR 13 Is2oi Application Type Revision Code Version 2017 ST. Lucie County, Permiiing� Application Status Approved Comments Archived r1 Product Manufacturer TAMKO Building Products,Inc. Address/Phone/Email PO Box 1404 Joplin,MO 6480 11 (417)624- Ext LM kerri_eden@taro.co 1L C 0py Authorized Signature Kerri Eden kerri_eden@tamkD.com Technical Representative Kerri Eden Address/Phone/Email PO Box 1404 Joplin,MO 64802 (417)624-6644 Ext 2305 kerri_eden@tamko.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer i Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Zachary R.Priest Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/18/2.021 Validated By Locke Bowden P.E. Validation Checklist-Hardcopy Received Certificate of Independence FL18355 R4 COI TBP15001.4 2017 FBC Evai Report Shingles final.odf Referenced Standard and Year(of Standard) ,Standard Year ASTM D 3161 2016 ASTM D 3462 2010 ASTMD D 7158 2011 TAS 100 1995 Equivalence of Product Standards Certified By Approved Testing Lab FL18355 R4 Enuiv UL letter for-standards for FBC 2017.12df hfps:/Moridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgwosrHazGXQW83MPT3uofKzDIM2Xu9wuWmY6POIJIukQa/o3d%3d 1/2 Certificate of Authorization No.29824 ' � 17520 Edinburgh Dt Lsrt Tampa,FL 33647 TECHNICAL,SekvimS, LLC. (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,6m EnmoN(2017) Manufacturer: TAMKO BUILDING PRODUCTS issued September 25,2017 220 West 0 Street Joplin,MO 64801 (417)624-6644 Manufacturing Plants: Joplin,MO Phillipsburg,KS Frederick,MD Dallas,TX Tuscaloosa,AL Quality Assurance: UL LLC(QUA9625) SCOPE Category: Roofing Subcategory: Asphalt Shingles Code Sections: 1504.1.1,1507.2.5, 1507.2.7.1, 1523.6,5:1 Properties: Physical properties,Wind Resistance,Wind Driven Rain REFERENCES -- Entity Report No. Standard Year PRI Construction Materials Technoiogies.(rST5878) TAP=043-02-01 TAS,100 1995 PRI Construction Materials Technologies(TST5878) TAP-051-02-01 TAS 10tt 1995 PRI Construction Materials Technologies(TST5878) TAP-054-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-114-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP=117-02-01 TAS 100 .1995 PRI Construction Materials Technologies(TST5878) TAP-130-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-131-02-01 TAS 100 1995 PRI Construction Materials Techriologles(TST5878) TAP-165-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-280-02-41 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-303-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-307-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-314-02-01 Rev 2 TAS 100 1995 PRI Construction Materials Technologies(TST5878) TAP-315-02-01 ASTM D 6381 2008(2013)e1 PRI Construction Materials Technologies(TST5878) TAP-317-02-01 TAS 100 1995 UL LLC(TST9628) 02NK9507 ASTM D 3161 2016 UL LLC(TST9628) 04NK24366 ASTM D 3462 2010A UL LLC(TST9628) 05NK28006 ASTM D 6381 2008(2013)e1 UL 2390 ASTM D 7158 2011 UL LLC(TST9628) 06NK03898 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC(TST9628) 08CA59132 ASTM D 3161 2016 UL LLC(TST9628) 09NK07896 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC(TST9628) 10CA50498 ASTM D 3462 2010A UL LLC(TST9628) 10CA64882 ASTM D 3161 2016 UL LLC(TST9628) 11NK14014 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC(TST9628) 12CA24551 ASTM D 3161 2016 UL LLC(TST9628) 4786110543 ASTM D 6381 2008(2013)e1 UL LLC OW9628) 4787043752 ASTM D 3161 2016 UL LLC(17ST9628) 4787148748 ASTM D 7158 2011 ASTM D 3161 2016 ASTM D 3462 2010A CREEK Technical Services LLC(ANE11669) T81215001.3 Calculations 2017 T131215001 A FL18355-R4 Page 1 of 11 This evaluation deport Is provided for State of Florida product approval under Rule 61:;20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid'. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES,LLC PRODUCT DESCRIPTION Elite Glass-Seal® 12-114"x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab (Frederick,Joplin& asphalt shingle with fiberglass mat coated on both.sides with asphalt and surfaced with Tuscaloosa) ceramic granules complying with ASTM D 3462. Glass-Seal . 12-114"x 36",ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab (Frederick& asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with Tuscaloosa) ceramic granules complying with ASTM D 3462. Glass-Seal 12-1/4"x 36";ASTM D 7158,Class H self-sealing,3-tab asphalt shingle with fiberglass (Joplin) mat coated on both sides with asphalt and surfaced with ceramic granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only... Heritages: 13-1/4" x 39-318", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas,Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules Joplin,Ptlllpslaur & complying with ASTM D 3462. Tuscaloosa) Hen remium 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass (Dallas,Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules Phillipsburg& complying with ASTM D 3462. Tuscaloosa) Heritage®Premium 12" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced,. (Frederick) laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage®Vintage® 17-11T x 40",ASTM D 3161, Class F and ASTM D 7158,Class H fiberglass reinforced, (Phillipsburg) laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage®Woodgate 13-1/4" x 39-318", ASTM D 3161, Class F and ASTM D-7158, Class H fiberglass (Dallas&Frederick) reinforced, laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. , .Heritage®Woodgate 12" x"36-/8", ASTM D 3161, Class F fiberglass reinforced, laminated architectural (Frederick) asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. Hip and Ridge Shingles 12-114" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt (Frederick&Joplin) shingle surfaced with mineral granules complying with ASTM D 3462. Vintage®Hip and Ridge 12"x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle (Phillipsburg) surfaced with mineral granules complying with ASTM D 3462. TBP1.5001.4 FL18355-114 Page 2 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. TAKO BUILDING PRODUCTS VRE Asphalt Shingles TECHNICAL SERVICES,LLC INSTALLATION Elite Glass-Sear Basic Wind Speed(Vwr): Max. 194 mph (Frederick,Joplin& Basic Wind Speed(Veld): Max. 150 mph ' Tuscaloosa) Deck(HVHZ): in accordance with FBC requirements; & Solidly sheathed min. 19132 in, plywood or wood plank for Glass-Seal new construction; Min. 15132 in. plywood existing (Frederick.,Joplin(Non- construction. . HVHZ)&Tuscaloosa) Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed nun. 15132 In. plywood or wood plank for new construction;Min.7/16 in.OSB existing construction. Underiayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation(HVHZ): installed with 5-1/8 inch exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern detailed below. Installation (Nan-HVHZ): Installed with 5-1/84nch exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or T Nail Pattern'detailed below. NAIL$ 77 AM Figure 1. Elite Glass-Seal&Glass-Seal 4 Nail Pattern (Non-HVHZ only) MAILS — - 67.7M" hlaili�9 ---: _.. -- -- �-7113" Butt Edge Figure 2. Elite Glass-Seal&Giass-Seal 6 Nail Pattern T13015001A FL18353-R4 Page 3 of 11 This evaluation'report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. �''+ TAMKO BUILDING PRODUCTS ti.�+REE AsphaltShingles TECHNICAL SERVICES,LLC Heritage® Basic Wind Speed(Vuo: Max. 194 mph (Dallas,Frederick,Joplin, Basic Wind Speed(Vesd): Max.150 mph Phillipsburg&Tuscaloosa) Deck(HVHZ): In accordance with FBC requirements; & Solidly sheathed min. 19/32 in. plywood or wood plank for HeritageO Premium new construction; Min. 16/32 in. plywood existing (Dallas,Frederick .. construction. Phillipsburg&Tuscaloosa) Deck(Non-HVHZ): In accordance with FBC requirements; & Solidly sheathed min. 15132 in. plywood or wood plank for HeritageO Woodgate new construction;Min.7/16 in.OSB existing construction. (Dallas&Frederick) Underiayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application-Instructions.when installing shingles at slopes greater than 21:12. Installation(HVHZ): Installed with 5-5/8 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern' detailed below. . Installation (Nan-HVHZ): Installed with 5-518 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattem"or"6 Nail Pattem"detailed below. NAIL ZONE FASTENERS COMMON - BOND -1I8° EXPOSURF-6-wl 12"-3/$" -�►— 1.2=1!2'� �—�n Figure 3. Heritage®,HeritageO Premium,and HerltageV Woodgate(Dallas) 4 Nall Pattern(non-HVHZ only) —FASTENERS NAIL ZONE COMMON BOND t3-118" 7EXPOSURE 5-5/8" Figure 4. Heritage@&Heritage®Premium 6 Nail Pattern TBP15001.4 FL18355-R4 Page 4 of 11 This-evaluation report is provided for State of Florida product approval under Rule 81 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. CREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES,LLC WIN km .ASTENEI3 CON!IMN BONA _-_ - v "= � �4+V2+V-1A%+- :12 Figure S. Heritage®Woodgate 6 Nail Patter -►I '� 12-1/2' Common Bond 1 FASTENERS � T .. .. ._ ........-. _ Figure 6. Heritage®, Heritage®Premium,&Heritage®Woodgate Alternate 6 Nail Pattern PAINT LINE- 7 L'ZflNE 6-118" `- -"EDGE OF. COMMON 'BOND EXPOSURE _ ACCI:RT16LE- FASTENER LOCATION DO.NOT FASTEN ALONG.EDGE OF -- COMMON'BOND PREFERRED FASTENER LOCATION Figure 1. Heritage®(Tuscaloosa) Expanded Nail Zone Nall patterns from Figures 3,4,and 6 may be placed in the nall zone as described above TB.P15001.4 FL18355-114 Page 5 of 11 This evaluation report is provided for State of Florida product approval under Rule 81G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. TAMKO BUILDING PRODUCTS CREEK AsphaftShingles TECHNICAL SERVICES,LLC Horftge@ Premium Basic Wind Speed(Vuu): Max. 194 mph (Frederick) Basic Wind Speed(Vaw): Max.150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBG requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction;Min.7116 in.OSB existing construction. Undeflayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application Instructions when installing -shingles at slopes greater than 21:12.. Installation(HVHZ): Installed with 5 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern' detailed below. Installation (Non-HVHZ): Installed with 5 In. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either a4 Nail Pattern"or"6 Nail Pattern"detailed below. NAIL ZONE/ FASTENERS COMMON BLIND r -1 6112 nn. WRE-V F9 Ila 12n Ila �l H Figure S. Heritage@ Premium(Frederick) 4 Nail Paftem(non-HVHZ only) NAIL ZONE/ FASTENERS COMMON BOND T 7 51/2 EXPOSURE Sn' Figure 9. HeritagelD Premium(Frederick) 6 Nail Pattern TBP15001A FL18356-R4 Page 6 of 11 This evaluation report Is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CRESR Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation,report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. CREEK BUILDING PRODUCTS K Asphalt Shingles TECHNICAL SERVICES,LLC Heritage®Woodgate Basic Wind Speed(Vw4: Max. 194 mph (Frederick) Basic Wind Speed.(V Q: Max. 150 mph Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15132 in. plywood or wood plank for new construction;Min.7/16 in.OSB existing construction. Underiayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application Instructions when installing shingles at slopes greater than 21:12. Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either 04 Nail Pattern"or"6 Nail Pattern"detailed below. _. ._ NAIL ZONEI FASTENERS COMMON BOND - - 5-if2" EKPOSURE 5° jL i'-� �-. 11" =�-12-318"•-�:. 11" -Irl �i-,1" Figure 10. Heritage®Woodgate(Frederick) 4 Nail Pattern(non-HVHZ only) NAIL ZONFI FASTENERS:: i1q/- - - COMMON BOND 5.112' EXPOSURE 5" 3 - t 1"'�'1 �,8-112"�1�3'�f�9.�I$"—�.3'1�g.1Jg■.� �u Figure 11. Heritage®Woodgate (Frederick) 6 Nail Pattern TBP15001.4 FL18355-114 Page 7 of 11 This-evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use.'or other product attributes that are not specifically addressed herein. CREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES,LLC Heritage®Vintage® Basic Wind Speed(V„n): Max.194 mph (Phillipsburg) Basic Wind Speed(Vaw): Max.150 mph Deck(HVHZ): in accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood .existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction;Min.7/16 in.OSB existing construction. Underiayment: In accordance,with FBC.requirements. Min.slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application.instructions when installing shingles at slopes greater than 21:12. Installation(HVHZ): Installed with 5 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Nan-HVHZ): Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"5 Nail Pattern"or"6 Nail Pattern"detailed below. - -- - 4a' _ Rposuie rMMI aur avr aur'- aim' v Figure.12. Heritage®Vintage® 5 Nail Pattern (non-HVHZ only) lie Ttrxr� s< Figure 13. Heritage®Vintage® 6 Nail Pattem TBP15001.4 FL18355-R4 Page 8 of 11 This evaluation report is provided for State of Florida product approval under Rule 61620-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,"instaltation,recommended use,or other product attributes that are not specifically addressed herein. CREEK TAMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES,LLC Hip&Ridge Basic Wind Speed(V,e): Max. 194 mph (Frederick&Joplin) Basic Wind Speed(Vow): Max. 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction;Min.7/16 in.OSB existing construction. - Underlayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Installation: Installed with 5-1/8 inch exposure in accordance with the FBC and manufacturer's published installation instructions. The direction of the exposed end shall be away from the prevailing wind: Direction prevailing wind start 5-1/$"exposure here _ Figure 1 here 5-1/8"exposure ' ? FastenerFastener t6-515" I✓a�IgD Figure 2 Figure 3 Figure 14. Hip&Ridge(Frederick&Joplin) TBP15001.4 FL18355-R4 Page 9 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which.this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. CREEKj,� TAMKO BUILDING PRODUCTS . Asphalt Shingles TECHNICAL,SERv1icEs,LLC Vintage®Hip&Ridge Basic-Wind Speed-(Vwty Max. 194 mph (Phillipsburg) Basic Wind Speed(Vasa): Max. 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction;Min.7/16 in.OSB existing construction. Undedayment: In accordance with FBC requirements. Min.slope: 2:12 and in accordance with FBC requirements. Installation; Installed with 5 inch exposure in accordance with the FBC and manufacturer's published installation instructions: The direction of the exposed, end shall be away from the prevailing wind. Direetlono prevWling wind it 15"exposure n 4 start-- o S, here Figure 1 5" exposure 5 or ' fastener Peste�n ,�I t �5-1/2" Figure 2 1/4�, Figure 3 Figure 15. Vintage®Hip &Ridge(Phillipsburg) TBP15001.4 FL1835&R4 Page 10 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not _ specifically addressed herein. • TAMKO BUILDING PRODUCTS CREEK Asphalt Shingles TECHNICAL SERVICES,LLC LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ. 4) Classification to ASTM D 7158 applies to exposure B&C with a building mean roof height of 60 ft or less. 5) Deck substrates shall be`clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the deck. 7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources,the more restrictive and code compliant detail shall prevail. 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE,STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code,6Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer. Gia•ORIFs-., 2017.09.25 No 74021 11 :31 :41 -A: STATE OF -04'00' �iO**. A,• � p P.����•� Zachary R.Priest, P.E. �0i� •'••�R •••• �� Florida Registration No.74021 ���SS;ONA Et,' Organization No.ANE11669 CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product END OF REPORT TBP15001 A FL18355-R4 Page 11 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for-which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. RECEIVED EXTERIOR RESEARCH&DESIGN,I.I.C. MAR 13 2020 Certificate of Authorization#9503 QOTRINITYIERD 353 CHRISTIAN STREET,UNIT ST. Lucie County, Permitting OXFORD,CT 06447878 (203)262-9245 EVALUATION REPORT TRI-BUILT Materials Group,LLC pNfuation Report A42960.10.12-R6 PO Box 70 FL16048=Ri6 Rutherford, NJ 07070 FILE Date of Issuance:10/25/2012 (800)516-1485 Revision 6: 09/25/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6u' Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: TRI-BUILT Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinityl ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: ,l,,,�sf��ft;r,,,•�- Gam.,-.t�a•s?Iva Robert J.M. Nieminen,P.E. •.Fs; ,;E' •• ��� ii,..t`• The facsimile seal appearing was authorized by Robert Nieminen, Florida Registration No.59166,Florida DCA ANE1983 P.E.on 09/25/2017.This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product-. 5. This.is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. QOTRINITYIERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: TRI-BUILT Roof Underlayments, as produced by TRI-BUILT Materials Group, LLC, have demonstrated compliance with the following sections of the 6u'Edition(2017)Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation.Requirements and Limitations/ Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Resistance FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1504.6 Accelerated Weathering ASTM G155 2005 1507.2.4/-1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012(04-12) 2012 3. REFERENCES: Enfltv Examination Reference Date ERD(TST6049) Physical Properties 540540.02.13-1 02/19/2013 ERD(TST6049) Physical Properties S40540.11.13 11/19/2013 ERD(TST6049) Physical Properties 540540.03.14 03/26/2014 ERD(TST6049) Physical Properties 544870.04.14-2 04/02/2014 ERD(TST6049) Physical Properties 544870.04.14-3 04/02/2014 ERD(TST6049) Physical Properties 544870.04.14-1 04/10/2014 ERD(TST6049) Physical Properties S44870.04.14-4 04/10/2014 ERD(TST6049) Physical Properties 543530.02.14-1-R1 05/14/2014 ERD(TST6049) Physical Properties S43530.05.14 05/28/2014 ERD(TST6049) Physical Properties S40540.10.14 10/31/2014 ERD(TST6049) Physical Properties SC7645.02.15 02/13/2015 ERD(TST6049) Accelerated Weathering SC8520.04.15 05/27/2015 ERD(TST6049) Wind Resistance SC14045.05.17-R1 06/07/2017 UL,LLC.(QUA9625) Quality Control Multiple-Listing R16814 12/10/2015 UL,LLC.(QUA9625) Quality Control Service Confirmation Exp.07/18/2020 4. PRODUCT DESCRIPTION: 4.1 :Tri-Built Sand=R.,SA Shingle. Underlaymentis a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment,with a 36-inch sheet width;meets ASTM D1970. 4.2 Tri-Built S/A HT TU Underlayment is a self-adhering, non-woven polyester fabric surfaced, SBS modified. bitumen roof underlayment;meets ASTM D1970 and FRSA/TRI April 2012. 4.3 Tri-Built Smooth HT S/A Underlayment is a self-adhering, glass-mat reinforced,, film-surfaced, SBS modified bitumen roof underlayment;meets ASTM D1970. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,LLC. Evaluation Report A42960.10.12-R6 Certificate of Authorization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL16048-R6 TRI-BUILT Roof Underlayments,(800)516-1485 Revision 6:09/25/2017 Page 2 of 6 QTORIN11YIERD 5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: xry a PONS ��` ` ' �� " Underlayment Asphalt Nail-On Tile Foam-On Tile Metal Wood Shakes Slate Shingles &Shingles Tri-Built Sand-R SA Shingle Yes No No No Yes Yes Underlayment Tri-Built S/A HT TU Yes Yes Yes Yes Yes Yes Underlayment See 5.5.1 Tri-Built Smooth HT S/A Yes No No Yes Yes Yes Underlayment 5.5.1 "Foam-On Tile"is limited to use of the following Approved tile adhesives/underlayment combinations. .nh�E,"T,t' �, .w'x�Ft�£ -'Y-'�-t '�s'Hs°` .�aW7st�,F'+'��`'"1,.r_""�:ni'_k�T�"a�-'�T' 'a-�:.ss."�r�=2:�'.Y"' `35 i,: �'C+�e'_'�"�'"1 'v.,"°Y s�'�"�'�`•`' -�-%Sx _`�i = , .'x�+€ cr�'""3*xaFw.a<i.�3>Y-x..- #..,�.,r.Y.rm�us•.`��..«..s,.r.,�_�...�_»x._vrs ;_:� •..-a�;z-,a..�+:.Y--�i..Sw�.r:>.::�sr:dR�-x,::,rx..c:�'„-..+�. ,..,.�_L�i.,�. '� �,r'3"', --., Adhesive Florida Product Approval Underlayments ICP Adhesives Polyset®AH-160 FL6332 Tri-Built S/A HT TU Underlayment Dow TileBond°" FL22525 Tri-Built S/A HT TU Underlayment 5.6 Allowable Substrates: 5.6.1 Direct-Bond to Deck: Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ➢ Plywood;ASTM.D41 primed plywood; OSB;ASTM D41 primed OSB;Southern Yellow Pine;ASTM D41 primed Southern Yellow Pine;ASTM D41 primed structural concrete. While not required over plywood,OSB or Southern Yellow Pine substrates,TRI-BUILT Materials Group,LLC recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note: TRI-BUILT Materials Group, LLC requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the self-adhering underlayment. 5.6.2 Bond-to-Insulation: Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ➢ . Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on the systems (Tri-Built S/A HT TU Underlayment only), insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474,Appendix D or TAS.114,Appendix J. 1 Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. Exterior Research and Design,I.I.C. Evaluation Report A42960.10.12-R6 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION F1.36048-116 TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6:09/25/2017 Page 3 of 6 Q0TRINITYIERD 5.6.3 Bond to Mechanically Attached Base Laver: Tri-Built Sand-R SA Shingle Underlayment;Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ➢ ASTM D226,Type I or II felt. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam-on tile systems (Tri-Built S/A HT TU Underlayment only), base layer shall be.attached per minimum requirements of FRSA/TRI April 2012(04- 12). 5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where the underlayment forms part of the load-path. The following wind uplift limitations apply to direct-deck underlayment systems that are not addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012(04-12),Appendix A,.Table 1A or FBC 1609 for determination of design wind pressures. #1 Maximum Design Pressure=-45.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional)ASTM D41 or RESISTO EXTERIOR PRIMER Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered. #2 Maximum Design Pressure=-67.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Soprema Elastocol 600c Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered. #3 Maximum Design Pressure=-150.0 psf: Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to.meet project requirements to satisfaction of Authority Having Jurisdiction. Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All sheathing fasteners shall be driven flush with"the surface. All sharp splinters and wood projections shall be removed/sanded. Primer: (Optional)RESISTO EXTERIOR PRIMER Underlayment: Tri-Built S/A HT TU Underlayment, self-adhered, shall be thoroughly roll using hand roller and/or weighted roller to ensure there are no voids, and ensure there are no voids/bridging at side and end-laps. #4 Maximum Design Pressure=-60.0 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Soprema Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps(FBC 1517.5.2)spaced 6-inch o.c.at:the 4-inch laps and 6-inch o.c. in three, equally spaced rows in the center of the sheet. Underlayment: Tri-Built 5/A HT TU Underlayment;self-adhered. Exterior Research and Design,LLC. Evaluation Report A42960.10.12-R6 Certificate of Authorization#9503 6EDITION(2017)FBC NON-HVHZ EVALUATION FL16048-R6 TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6:09/25/2017 Page 4 of 6 Q0TR1N1-ff' jE R. D 5.6.4.1 For mechanically attached Base Sheet,the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements. 5.7 Exposure Limitations: Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left exposed for longer than 30-days after installation Tri-Built S/A HT TU Underlayment shall not be left exposed for longer than 180-days after installation. 5.8 Tile Slippage Limitations(TAS 103 per FRSA/TRI April 2012(04-12)): When loading roof tiles on the underlayment in direct-deck the assemblies,the maximum roof slope shall be as follows. These slope limitations can only be exceeded by-using battens during loading of the roof tiles. Underlayment Tile Profile Staging Method Maximum Slope Flat Max.10-tile stack 6:12 Lugged Max.10-tile stack 5:12 Max.10-tile stack(bottom 2-tile stack shall be inverted,followed by 8 tiles high 6:12 on slope,as shown`below) Tri-Built 5/A HT TU �4 Underlayment Lugged Exterior Research and Design,I.I.C. Evaluation Report A42960.10.12-R6 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVH2 EVALUATION FL16048-R6 TRI-BUILT Roof Underlayments,(800)516-1485 Revision 6:09/25/2917 Page 5 of 6 . Q0TR1N_ 1-'TY1ERD 6. INSTALLATION: 6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT Materials Group, LLC published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate(if applicable). 6.3 Tri Built Sand-R SA Shingle Underlayment Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment: 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table . 1507.1.1 for the type of prepared roof covering to be installed. 6.3.2 Non-Tile applications: While priming is optional,TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. Adhere the.exposed part to the substrate and unroll the remaining membrane as far as possible. Once the entire length of membrane is .in place,-peel-off the release film diagonally while holding the membrane tight. Firmly roll,broom or hand-press the membrane into place to achieve a bond. Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6- inches and staggered not less than 2-ft from vertical seams in the course below,,sealed in accordance with TRI-BUILT Materials Group,LLC requirements. When installing at slopes above 8:12, TRI-BUILT Materials Group, LLC recommends back-nailing in the overlap area at the top of the sheet at 12-inch o.c. For Valleys a'nd Ridges: Cut underlayment into 4 to 6 foot lengths.Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction. For valleys,apply the sheet starting at the lowest point and work upward. 6.3.3 Tile Applications(Tri-Built S/A HT TU Underlayment only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For foam-on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations,that fall outside the scope of FRSA/TRI April 2012(04-12). Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. See Table 2 herein, and TRI-BUILT Materials Group, LLC published requirements for tile staging. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. S. MANUFACTURING PLANTS: Gulfport,MS 9. QUALITY ASSURANCE ENTITY: ULLLC—QUA9625;(314)578-3406;k.chancellor@Xjs.u.I.com " -END OF EVALUATION REPORT- Exterior Research and Design,U.C. Evaluation Report A42960.10.12-R6 CertiTicate of Authorization#9503 6r"EDITION(2017)FBC NON-HVHZ EVALUATION A16048-116 TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6:09/2S/2017 Page 6 of 6