HomeMy WebLinkAboutPERMIT PACKAGE03/17/2020
Building height Zone 4 I
Area 15 20 25 30 35 40 45 50 55 60
10 pos 37.9 40.4 42.3 43.8 45.4 46.7 47.9 48.9 49.8 50.7
neg 41.1 43.8 45.9 47.5 49.2 50.6 52 53 54 55
20 pos 36.3 38.7 40.5 42 43.5 44.7 45.9 46.8 47.7 48.6
neg 39.4 42 44 45.6 47.2 48.5 49.8 50.8 51.8 52.8
50 pos 35.4 37.7 39.4 40.9 42.4 43.5 . 44.7 45.6 46.5 47.3
neg 37.1 39.6 41.4 42.9 44.5 45.7 46.9 47.8 48.7 49.7
\100 pas 32.2 34.4 36 37.3 38.6 39.7 40.8 41.6 42.4 43.2
neg 35.4 37.8 39.5 41 42.5 43.6 44.8 45.7 46.6 47.4
500 pas 28.2 30.1 31.5 32.7 33.8 34.8 35.7 36.4 37.1 37.8
neg 31.4 33.5 35.1 36.4 37.7 38.7 40.5 39.7 41.3 42.1
Building height End zone 5
15 20 25 30 35 40 45 50 55 60
10 pas. 37.9 40.4 42.3 43.8 45.4 46.7 47.9 48.9 49.8 50.7
neg 50.7 54.1 56.6 58.7 60.8 62.5 64.2 65.4 66.7 67.9
20 pos 36.3 38.7 40.5 42 43.5 44.7 45.9 46.8 47.7 48.6
neg 47.3 50.5 52.8 54.8 56.7 58.3 59.8 61 62.2 63.4
50 pos 35.4 37.7 I 39.4 40.9 42.4 43.5 44.7 45.6 46.5 47.3
neg 42.8 45.6 47.7 49.5 51.2 52.7 54.1 55.1 56.2 57.3
100 pos 32.2 34.4 36 37.3 38.6 39.7 40.8 41.6 42.4 43.2
neg 39.4 42 44 45.6 47.2 48.5 49.8 50.8 51.8 52.8
500 pos 28.2 30.1 31.5 32.7 33.8 34.8 35.7 36.4 37.1 37.8
neg 31.4 33.5 35.1 36.4 37.7 38.7 39.7 40.5 41.3 I 42.1
Wind design Pressure Chart for structures subject to
Florida Residential Code 170 mph exposure C
Wall component and Cladding pressures from Table R302.2(2) modified by adjustment
factors from R301.1(3). Converted to Vasd according to R302.1.2.1.1
EGER762 SE RIVER LANE PSL,FL
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #FL15213-R3
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer Plastpro Inc. / Nanya Plastics Corp.
Address/Phone/Email 5200 W CENTURY BLVD.
LOS ANGELES, CA 90045
(440) 969-9773 Ext 16
rickw@rwbldgconsultants.com
Authorized Signature Vivian Wright
rickw@rwbldgconsultants.com
Technical Representative Scott Johnson
Address/Phone/Email 5200 W Century Blvd.
Los Angeles, CA 90045
(440) 969-9773 Ext 18
scottjohnson@plastproinc.com
Quality Assurance Representative Ron O'Connell
Address/Phone/Email 5200 W Century Blvd.
Los Angeles, CA 90045
(440) 969-9773 Ext 16
ronoconnell@plastpro.com
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblies
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
the Evaluation Report
Lyndon F. Schmidt, P.E.
Florida License PE-43409
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2021
Validated By Ryan J. King, P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence FL15213_R3_COI_(b) Certificate of Independence.pdf
Referenced Standard and Year (of Standard)Standard Year
101/I.S.2 1997
101/I.S.2/NAFS 2002
AAMA/WDMA/CSA101/I.S.2/A440 2005
ASTM E1886 2002
ASTM E1996 2002
ASTM E330 2002
TAS 201, 202, 203 1994
Page 1 of 5Florida Building Code Online
2/14/2020https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv3yVVKJZ1Q...
FL 15213.16_8 OPAGUE FIBERGLASS SINGLE DOOR
Equivalence of Product Standards
Certified By Florida Licensed Professional Engineer or Architect
FL15213_R3_Equiv_(a) Equivalency of Standards.pdf
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/20/2017
Date Validated 10/20/2017
Date Pending FBC Approval 10/24/2017
Date Approved 12/12/2017
Summary of Products
Go to Page Page 1 / 2
FL #Model, Number or Name Description
15213.1 a. Smooth/Wood Grain/White Wood
Grain/Rustic/Mahogany Series
Fiberglass Door
6'8 "Impact" Opaque Fiberglass Single Door -
Inswing/Outswing (X - Configuration)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: See INST 15213.1 for Design Pressure Ratings, any
additional use limitations, installation instructions and product
particulars.
Installation Instructions
FL15213_R3_II_(a) Inst 15213.1.pdf
Verified By: Lyndon F. Schmidt, P.E. 43409
Created by Independent Third Party: Yes
Evaluation Reports
FL15213_R3_AE_(a) Eval 15213.1.pdf
Created by Independent Third Party: Yes
15213.2 b. Smooth/Wood Grain/White Wood
Grain/Rustic/Mahogany Series
Fiberglass Door
6'8 "Impact" Opaque Fiberglass Single Door with Sidelite
utilizing "Snap Frame" Glazing - Inswing/Outswing (OX or XO
- Configurations)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: See INST 15213.2 for Design Pressure Ratings, any
additional use limitations, installation instructions and product
particulars.
Installation Instructions
FL15213_R3_II_(a) Inst 15213.2.pdf
Verified By: Lyndon F. Schmidt, P.E. 43409
Created by Independent Third Party: Yes
Evaluation Reports
FL15213_R3_AE_(a) Eval 15213.2.pdf
Created by Independent Third Party: Yes
15213.3 c. Smooth/Wood Grain/White Wood
Grain/Rustic/Mahogany Series
Fiberglass Door
6'8 "Impact" Opaque Fiberglass Single Door with Sidelites
utilizing "Snap Frame" Glazing - Inswing/Outswing (OXO -
Configuration)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: See INST 15213.3 for Design Pressure Ratings, any
additional use limitations, installation instructions and product
particulars.
Installation Instructions
FL15213_R3_II_(a) Inst 15213.3.pdf
Verified By: Lyndon F. Schmidt, P.E. 43409
Created by Independent Third Party: Yes
Evaluation Reports
FL15213_R3_AE_(a) Eval 15213.3.pdf
Created by Independent Third Party: Yes
15213.4 d. Smooth/Wood Grain/White Wood
Grain/Rustic/Mahogany Series
Fiberglass Door
6'8 "Impact" Opaque Fiberglass Single Door with Sidelite
utilizing "Lip Lite" Glazing - Inswing/Outswing (OX or XO -
Configurations)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: See INST 15213.4 for Design Pressure Ratings, any
additional use limitations, installation instructions and product
particulars.
Installation Instructions
FL15213_R3_II_(a) Inst 15213.4.pdf
Verified By: Lyndon F. Schmidt, P.E. 43409
Created by Independent Third Party: Yes
Evaluation Reports
FL15213_R3_AE_(a) Eval 15213.4.pdf
Created by Independent Third Party: Yes
15213.5 e. Smooth/Wood Grain/White Wood
Grain/Rustic/Mahogany Series
Fiberglass Door
6'8 "Impact" Opaque Fiberglass Single Door with Sidelites
utilizing "Lip Lite" Glazing - Inswing/Outswing (OXO -
Configuration)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Installation Instructions
FL15213_R3_II_(a) Inst 15213.5.pdf
Verified By: Lyndon F. Schmidt, P.E. 43409
Created by Independent Third Party: Yes
Page 2 of 5Florida Building Code Online
2/14/2020https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv3yVVKJZ1Q...
Design Pressure: N/A
Other: See INST 15213.5 for Design Pressure Ratings, any
additional use limitations, installation instructions and product
particulars.
Evaluation Reports
FL15213_R3_AE_(a) Eval 15213.5.pdf
Created by Independent Third Party: Yes
15213.6 f. Smooth/Wood Grain/White Wood
Grain/Rustic/Mahogany Series
Fiberglass Door
6'8 "Impact" Opaque Fiberglass Double Door -
Inswing/Outswing (XX - Configuration)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: See INST 15213.6 for Design Pressure Ratings, any
additional use limitations, installation instructions and product
particulars.
Installation Instructions
FL15213_R3_II_(a) Inst 15213.6.pdf
Verified By: Lyndon F. Schmidt, P.E. 43409
Created by Independent Third Party: Yes
Evaluation Reports
FL15213_R3_AE_(a) Eval 15213.6.pdf
Created by Independent Third Party: Yes
15213.7 g. Smooth/Wood Grain/White Wood
Grain/Rustic/Mahogany Series
Fiberglass Door
6'8 "Impact" Opaque Fiberglass Double Door with Sidelites
utilizing "Snap Frame" Glazing - Inswing/Outswing (OXXO -
Configuration)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: See INST 15213.7 for Design Pressure Ratings, any
additional use limitations, installation instructions and product
particulars.
Installation Instructions
FL15213_R3_II_(a) Inst 15213.7.pdf
Verified By: Lyndon F. Schmidt, P.E. 43409
Created by Independent Third Party: Yes
Evaluation Reports
FL15213_R3_AE_(a) Eval 15213.7.pdf
Created by Independent Third Party: Yes
15213.8 h. Smooth/Wood Grain/White Wood
Grain/Rustic/Mahogany Series
Fiberglass Door
6'8 "Impact" Opaque Fiberglass Double Door with Sidelites
utilizing "Lip Lite" Glazing - Inswing/Outswing (OXXO -
Configuration)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: See INST 15213.8 for Design Pressure Ratings, any
additional use limitations, installation instructions and product
particulars.
Installation Instructions
FL15213_R3_II_(a) Inst 15213.8.pdf
Verified By: Lyndon F. Schmidt, P.E. 43409
Created by Independent Third Party: Yes
Evaluation Reports
FL15213_R3_AE_(a) Eval 15213.8.pdf
Created by Independent Third Party: Yes
15213.9 i. Smooth/Wood Grain/White Wood
Grain/Rustic/Mahogany Series
Fiberglass Door
6'8 "Non-Impact" Glazed Fiberglass Single Door utilizing
"Snap Frame" Glazing - Inswing/Outswing (X - Configuration)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: N/A
Other: See INST 15213.9 for Design Pressure Ratings, any
additional use limitations, installation instructions and product
particulars.
Installation Instructions
FL15213_R3_II_(a) Inst 15213.9.pdf
Verified By: Lyndon F. Schmidt, P.E. 43409
Created by Independent Third Party: Yes
Evaluation Reports
FL15213_R3_AE_(a) Eval 15213.9.pdf
Created by Independent Third Party: Yes
15213.10 j. Smooth/Wood Grain/White Wood
Grain/Rustic/Mahogany Series
Fiberglass Door
6'8 "Non-Impact" Glazed Fiberglass Single Door with Sidelite
utilizing "Snap Frame" Glazing - Inswing/Outswing (OX or XO
- Configurations)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: N/A
Other: See INST 15213.10 for Design Pressure Ratings, any
additional use limitations, installation instructions and product
particulars.
Installation Instructions
FL15213_R3_II_(a) Inst 15213.10.pdf
Verified By: Lyndon F. Schmidt, P.E. 43409
Created by Independent Third Party: Yes
Evaluation Reports
FL15213_R3_AE_(a) Eval 15213.10.pdf
Created by Independent Third Party: Yes
15213.11 k. Smooth/Wood Grain/White Wood
Grain/Rustic/Mahogany Series
Fiberglass Door
6'8 "Non-Impact" Glazed Fiberglass Single Door with Sidelites
utilizing "Snap Frame" Glazing - Inswing/Outswing (OXO -
Configuration)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: N/A
Other: See INST 15213.11 for Design Pressure Ratings, any
additional use limitations, installation instructions and product
particulars.
Installation Instructions
FL15213_R3_II_(a) Inst 15213.11.pdf
Verified By: Lyndon F. Schmidt, P.E. 43409
Created by Independent Third Party: Yes
Evaluation Reports
FL15213_R3_AE_(a) Eval 15213.11.pdf
Created by Independent Third Party: Yes
15213.12 l. Smooth/Wood Grain/White Wood
Grain/Rustic/Mahogany Series N
Fiberglass Door
6'8 "Non-Impact" Glazed Fiberglass Double Door utilizing
"Snap Frame" Glazing - Inswing/Outswing (XX -
Configuration)
Page 3 of 5Florida Building Code Online
2/14/2020https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv3yVVKJZ1Q...
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: N/A
Other: See INST 15213.12 for Design Pressure Ratings, any
additional use limitations, installation instructions and product
particulars.
Installation Instructions
FL15213_R3_II_(a) Inst 15213.12.pdf
Verified By: Lyndon F. Schmidt, P.E. 43409
Created by Independent Third Party: Yes
Evaluation Reports
FL15213_R3_AE_(a) Eval 15213.12.pdf
Created by Independent Third Party: Yes
15213.13 m. Smooth/Wood Grain/White Wood
Grain/Rustic/Mahogany Series N
Fiberglass Door
6'8 "Non-Impact" Glazed Fiberglass Double Door with
Sidelites utilizing "Snap Frame" Glazing - Inswing/Outswing
(OXXO - Configuration)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: N/A
Other: See INST 15213.13 for Design Pressure Ratings, any
additional use limitations, installation instructions and product
particulars.
Installation Instructions
FL15213_R3_II_(a) Inst 15213.13.pdf
Verified By: Lyndon F. Schmidt, P.E. 43409
Created by Independent Third Party: Yes
Evaluation Reports
FL15213_R3_AE_(a) Eval 15213.13.pdf
Created by Independent Third Party: Yes
15213.14 n. Smooth/Wood Grain/White Wood
Grain/Rustic/Mahogany Series N
Fiberglass Door
6'8 "Non-Impact" Glazed Fiberglass Single Door utilizing “Lip
Lite” Glazing - Inswing/Outswing (X - Configuration)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: N/A
Other: See INST 15213.14 for Design Pressure Ratings, any
additional use limitations, installation instructions and product
particulars.
Installation Instructions
FL15213_R3_II_(a) Inst 15213.14.pdf
Verified By: Lyndon F. Schmidt, P.E. 43409
Created by Independent Third Party: Yes
Evaluation Reports
FL15213_R3_AE_(a) Eval 15213.14.pdf
Created by Independent Third Party: Yes
15213.15 o. Smooth/Wood Grain/White Wood
Grain/Rustic/Mahogany Series N
Fiberglass Door
6'8 "Non-Impact" Glazed Fiberglass Single Door with Sidelite
utilizing “Lip Lite” Glazing - Inswing/Outswing (OX or XO -
Configurations)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: N/A
Other: See INST 15213.15 for Design Pressure Ratings, any
additional use limitations, installation instructions and product
particulars.
Installation Instructions
FL15213_R3_II_(a) Inst 15213.15.pdf
Verified By: Lyndon F. Schmidt, P.E. 43409
Created by Independent Third Party: Yes
Evaluation Reports
FL15213_R3_AE_(a) Eval 15213.15.pdf
Created by Independent Third Party: Yes
15213.16 p. Smooth/Wood Grain/White Wood
Grain/Rustic/Mahogany Series N
Fiberglass Door
6'8 "Non-Impact" Glazed Fiberglass Single Door with Sidelites
utilizing “Lip Lite” Glazing - Inswing/Outswing (OXO -
Configuration)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: N/A
Other: See INST 15213.16 for Design Pressure Ratings, any
additional use limitations, installation instructions and product
particulars.
Installation Instructions
FL15213_R3_II_(a) Inst 15213.16.pdf
Verified By: Lyndon F. Schmidt, P.E. 43409
Created by Independent Third Party: Yes
Evaluation Reports
FL15213_R3_AE_(a) Eval 15213.16.pdf
Created by Independent Third Party: Yes
15213.17 q. Smooth/Wood Grain/White Wood
Grain/Rustic/Mahogany Series N
Fiberglass Door
6'8 "Non-Impact" Glazed Fiberglass Double Door utilizing “Lip
Lite” Glazing - Inswing/Outswing (XX - Configuration)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: N/A
Other: See INST 15213.17 for Design Pressure Ratings, any
additional use limitations, installation instructions and product
particulars.
Installation Instructions
FL15213_R3_II_(a) Inst 15213.17.pdf
Verified By: Lyndon F. Schmidt, P.E. 43409
Created by Independent Third Party: Yes
Evaluation Reports
FL15213_R3_AE_(a) Eval 15213.17.pdf
Created by Independent Third Party: Yes
15213.18 r. Smooth/Wood Grain/White Wood
Grain/Rustic/Mahogany Series N
Fiberglass Door
6'8 "Non-Impact" Glazed Fiberglass Double Door with
Sidelites utilizing “Lip Lite” Glazing - Inswing/Outswing
(OXXO - Configuration)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: N/A
Other: INST 15213.18 for Design Pressure Ratings, any
additional use limitations, installation instructions and product
particulars.
Installation Instructions
FL15213_R3_II_(a) Inst 15213.18.pdf
Verified By: Lyndon F. Schmidt, P.E. 43409
Created by Independent Third Party: Yes
Evaluation Reports
FL15213_R3_AE_(a) Eval 15213.18.pdf
Created by Independent Third Party: Yes
Page 4 of 5Florida Building Code Online
2/14/2020https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv3yVVKJZ1Q...
15213.19 s. Smooth/Wood Grain/White Wood
Grain/Rustic/Mahogany Series N
Fiberglass Door
8’0 "Impact" Opaque Fiberglass Single Door -
Inswing/Outswing (X - Configuration)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: INST 15213.19 for Design Pressure Ratings, any
additional use limitations, installation instructions and product
particulars.
Installation Instructions
FL15213_R3_II_(a) Inst 15213.19.pdf
Verified By: Lyndon F. Schmidt, P.E. 43409
Created by Independent Third Party: Yes
Evaluation Reports
FL15213_R3_AE_(a) Eval 15213.19.pdf
Created by Independent Third Party: Yes
15213.20 t. Smooth/Wood Grain/White Wood
Grain/Rustic/Mahogany Series N
Fiberglass Door
8’0 "Impact" Opaque Fiberglass Single Door with Sidelite
utilizing "Snap Frame" Glazing - Inswing/Outswing (OX or XO
- Configurations)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: INST 15213.20 for Design Pressure Ratings, any
additional use limitations, installation instructions and product
particulars.
Installation Instructions
FL15213_R3_II_(a) Inst 15213.20.pdf
Verified By: Lyndon F. Schmidt, P.E. 43409
Created by Independent Third Party: Yes
Evaluation Reports
FL15213_R3_AE_(a) Eval 15213.20.pdf
Created by Independent Third Party: Yes
Go to Page Page 1 / 2
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The
emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please
click here .
Product Approval Accepts:
Page 5 of 5Florida Building Code Online
2/14/2020https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv3yVVKJZ1Q...