Loading...
HomeMy WebLinkAboutProduct Approval 2/13/2018 Florida Building Code Online cause= - BCIS Home I Log In 1 User Registration I Hot Topics Submit Surcharge Stats&Facts i Publications i FBC Staff i. BCIS Site Map j Links Search i Florida I Product Approval f`.L` FIV F ltx4-0. USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail MAR 17 2021 � a FL# FL20378-R1 ST. Lucie County, Permitting Application Type Revision Code Version 2017 Application Status Approved Comments Archived F I Product Manufacturer Extreme Metal Fabricators,LLC Address/Phone/Email 2160 SW Poma Drive Palm City,FL 34990 (772)872-8034 �(N flvalidation@yahoo.com Authorized Signature Richard McKuhen �� � ��(� � flvalidation@yahoo.com �e �7�a DF Technical Representative Richard McKuhen (COUNT� Address/Phone/Email 2160 SW Poma Drive u�QF Palm City,FL 34990 ��° (772)872-8034 richard@emfab.net Quality Assurance Representative -I+, nn `+ Address/Phone/Email IrlCopy Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the LOCKE BOWDEN Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By Zachary R.Priest,P.E. .i Validation Checklist-Hardcopy Received Certificate of Independence FL20378_ 11_C0I_FL 20378.1 NAILSTRIP 1.0_.032 ALUM_sss.pdf Referenced Standard and Year(of Standard) Standard Year TAS 125 2003 UL 1897 2012 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code hfps://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDqua%2f MZ8n5CNV4ZYkew5Zoa%2fE%2fovztglbhDVU2dJO4TAA%3d%3d 1/4 2/13/2018 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 08/18/2017 Date Validated 12/18/2017 Date Pending FBC Approval 10/17/2017 Date Approved 12/19/2017 Summary of Products FL* Model,Number or Name Description 20378.1 01-"1"Nailstrip" 0.032"Aluminum Standing Seam roof panel, 12"wide, mechanically attached to 15/32"plywood or Wood Deck with fasteners. Limits of Use Installation Instructions Approved for use in HVHZ:No FL20378_Rl_II_FL 20378.1 NAILSTRIP 1.0_.032 Approved for use outside HVHZ:Yes ALUM_sss.pdf Impact Resistant:No Verified By: Locke Bowden,P.E.49704 Design Pressure: +N/A/-Table A Created by Independent Third Party:Yes Other: Refer to evaluation report for Limitations and Evaluation Reports Conditions of Use.Refer to manufacturer's installation FL20378_R1_AE_FL 20378.1 NAILSTRIP 1.0_.032 instructions. ALUM_sss.pdf Created by Independent Third Party:Yes 20378.2 02-"1"Nailstrip" 26-gauge Steel Standing Seam roof panel, 16"wide, mechanically attached to 15/32"plywood or Wood Deck with fasteners and adhesive. Limits of Use Installation Instructions Approved for use in HVHZ:No FL20378_R1_II_FL 20378.2 Extreme Metal Fabricators_26GA Approved for use outside HVHZ:Yes NAIL STRIP 1.0.pdf Impact Resistant: No Verified By: Locke Bowden,P.E.49704 Design Pressure: +N/A/-Table A Created by Independent Third Party:Yes Other:Refer to evaluation report for Limitations and Evaluation Reports Conditions of Use.Refer to manufacturer's installationL2F 0378_Rl_AE_FL 20378.2 Extreme Metal Fabricators instructions. 26GA NAIL STRIP 1.0.pdf Created by Independent Third Party:Yes 20378.3 03-"1.75 Snap Lock" 0.032"Aluminum Standing Seam roof panel, 18"wide, mechanically attached to 15/32"plywood or Wood Deck with panel clips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ:No FL20378_R1_II_FL 20378.3 SNAP LOCK ALUM 1.75-ssr.pdf Approved for use outside HVHZ:-Yes Verified By: Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: +N/A/-Table A Evaluation Reports Other:Refer to evaluation report for Limitations and FL20378_R1_AE_FL 20378.3 SNAP LOCK ALUM 1.75-ssr.p1 Conditions of Use.Refer to manufacturers installation Created by Independent Third Party:Yes instructions. 20378.4 04-"1.75"Snap Lock" 24-gauge Steel Standing Seam roof panel, 18"wide, mechanically attached to 15/32"plywood or Wood Deck with panel clips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ:No FL20378_Ri_II—FL 20378.4 1.75 SNAP LOCK 24GA-ssr.pdf Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes .Design Pressure: +N/A/-Table A Evaluation Reports Other:Refer to evaluation report for Limitations and FL20378_R1_AE_FL 20378.4_1.75 SNAP LOCK 24GA-ssr.pdf Conditions of Use.Refer to manufacturers installation Created by Independent Third Party:Yes instructions. 20378.5 05-"Rib Panel" 29-gauge Steel exposed fastener roof panel,36"wide, mechanically attached to 15/32"plywood or Wood Deck with fasteners. Limits of Use Installation Instructions Approved for use in HVHZ:No FL20378_R1_II_FL 20378.5 RIB 29GA_ssr.pdf Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: +N/A/-Table A Evaluation Reports Other:Refer to evaluation report for Limitations and FL20378_RS_AE_FL 20378.5 RIB 29GA_ssr.odf Conditions of Use.Refer to manufacturers installation Created by Independent Third Party:Yes instructions. https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDqua%2f MZ8n5CNV4ZYkew5Zoa%2fE%2fovztglbhDVU2dJO4TAA%3d%3d 2/4 e � u 2/13/2018 Florida Building Code Online 20378.6 06-"5V Crimp" 26-gauge Steel exposed fastener roof panel,24"wide, mechanically attached to 15/32"Plywood or Wood Deck w/fasteners. Limits of Use Installation Instructions Approved for use in HVHZ:No FL20378_Rl_II_FL 20378. _5V Crimp_sss.pdf Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: +N/A/-Table A Evaluation Reports Other:Refer to evaluation report for Method 1 and Method 2 FL20378_R1_AE_FL 20378.6_5V Crimp_sss.pdf fastening. Limitations and Conditions of Use.Refer to Created by Independent Third Party:Yes manufacturer's installation instructions. 20378.7 07-"1.5 Standing Seam" 24-gauge Steel Standing Seam roof panel, 16"wide, mechanically attached to 15/32"plywood or Wood Deck with panel clips,fasteners and adhesive Limits of Use Installation Instructions Approved for use in HVHZ:No FL20378_R1_II_FL 20378.7 JM STANDING SEAM aar. ft Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: +N/A/-Table A Evaluation Reports Other: Refer to evaluation report for Limitations and FL20378_R1_AE_FL 20378.7 JM STANDING SEAM_ssr•pdf Conditions of Use.Refer to manufacturer's installation Created by Independent Third Party:Yes instructions. 20378.8 08-"Nordman Tile" 24-gauge Steel metal roof tile panel mechanically attached to 15/32"plywood or Wood Deck with fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No FL20378_R1_II_FL 20378.8_NORDMAN TILE 24G6_ssr.pdf Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: +N/A/-Table A Evaluation Reports Other: Refer to evaluation report for Limitations andLF 20378_R1_AE_FL 20378.8_NORDMAN TILE 24GAr p 1�f Conditions of Use.Refer to manufacturer's installation Created by Independent Third Party:Yes instructions. 20378.9 09-"Nordman Tile" 24-gauge Steel metal roof tile panel mechanically attached to Steel Deck with fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No FL20378_R1_II_FL 20378.9 Nordman Tile Details-ssr.pdf Approved for use outside HVHZ:Yes Verified By:James L. Buckner,P.E.@ CBUCK Engineering P.E. Impact Resistant: No #31242 Design Pressure: +N/A/-Table A Created by Independent Third Party:Yes Other:Refer to evaluation report for Limitations and Evaluation Reports Conditions of Use. Refer to manufacturer's installation FL20378_Rl_AE_FL 20378.9 Nordman Tile Details-ssr.pdf instructions. Created by Independent Third Party:Yes 20378.10 10-"Nordman Tile" 0.032"Aluminum metal roof tile panel mechanically attached to 15/32"plywood or Wood Deck with fasteners. Limits of Use Installation Instructions Approved for use in HVHZ:No FL20378_R1_II_FL 20378.10 NORD TILT.032 ALUM-ssr.pdf Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: +N/A/-Table A Evaluation Reports Other:Refer to evaluation report for Limitations and FL20378_Rl_AE_FL 20378.10 NORD TILT.032 ALUM-ssr.pdf Conditions of Use.Refer to manufacturer's installation Created by Independent Third Party:Yes instructions. Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.gMright 2007-2013 State of Florida.::EENMy Statement::Accessibility,Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please dick here. Product Approval Accepts: ® ECGEC M Credit Card Safe https://www.floridabuilding.org/pr/pr app_dtl.aspx?paraM=wGEVXQwtDqua%2flMZ8n5CNV4ZYkew5Zoa%2fE%2fovztglbhDVU2dJO4TAA%3d%3d 3/4 Product Report Manufacturer- Extreme Metal Fabricators, LLC. 2160 SW Poma Drive Palm City, Fl. 34990 872-8034 FI-orida Product A. . . Compliant with Florida Building Code 2017 (6th ed.) Compliant with Florida Product Approval Rule #61G20-3 Compliant : Keystone Certifications Product: 5 V Crimp 26GA Metal Roofing Panel Corrosion Resistant FBC Sec. 1507.4.3 Yield strength:40ksi Steel Attached to min. 15/32" plywood or Wood Deck w/ min. Attached 24" 0.42 specific gravity with screws. 24" Coverage Coverage Rib Height 3/8" Corrosion Resistant Compliant: FBC Sec. 1506, 1507 Fastener for Method 1 Attachment# 9-15 x 1"Hex Head w/EPDM Bonded Steel Washer to penetrate 3/16"thru wood decking Fastener for Method 2 Attachment#9-15 x 1"Hex Head w/EPDM Bonded Steel Washer to penetrate 3/16"thru 15/32"min. plywood.deck or 5/8"into wood plank Underlayment: To be compliant with FBC Sec.1507.1.1 Slope: Shall be in compliance with FBC Sec. 1507. Install Details: Table A Allowable Loads METHOD 1 METHOD 2 FASTENER PLACEMENT DESIGN PRESSURE* -85 PSF -114.25 PSF METHOD 11NRIB PEAKS ROW SPACING 12"O.C. 12"O.C. METHOD 21N PANEL FLATS FASTENER SPACING 12" O.C. 12"O.C. 'SEE INSTALL DRAWINGS FASTENER SIZE: A #9 1 #9 *ALLOWABLE DESIGN PRESSURE MARGIN OF 2 TO 1 Reference Data: HURRICANE TEST LAB#TST ID: 1527 .TAS 125-03 Test#0223-0307-01;METHOD 1 (UL 1897-041) TAS-125-03 Test#0223-0517-06,METHOD 2 'EQUIVALENCY UL 1897-04 IS EQUIVALENT TO UL 1897-12 TEST STANDARD * DESIGN PRESSURE SAFETY MARION 2:1 Certificate of Independence: Locke Bowden,P.E.does not have,not will acquire a financial interest in any company manufacturing or distributin products under this evaluation. ��� t �r Locke Bowden,P.E.is not owned,operated,or controlled by any company,manufacturer,or distributi-"4f �lidef,t�iiS� report. 4. �`'C) • ,I;,fi,V /+' '�i,. i n y Sl'i�i'E OF OROr fI' Itl1 "" a 6'•a h 2.1.. 7. l::ti111s''• Compliance Statement: These products herein evaluated have demonstrated compliance with the Florida Building Code 2017 61h ed.,with referenced documents submitted. Limitations: 1. Underlayment to be compliance with current Florida Building Code 2017 6th ed"Section 1507.1.1 2. Products are compliant for State of Florida product approval per Rule 61G20-3 3. Compliance Method: 1-D 4. Fire classification is not part of this acceptance.Shear diaphragm values are outside this report. 5. All support framing compliant w/Florida Building Code 2017,Chapters 22 for Steel,23 for Wood and 16 for Structural Loading.Design of support and attachment to the framing is outside the scope of this evaluation. 6. Rule 61G20-3 allows for engineering analysis by registered/licensed others for"project specific approval"by local authorities,authorized by the code,and is the responsibility of others. 7. This report does not imply warranty,installation, recommended product use outside of this report. Fasteners- #9-15 Hex-Head Screws With W-imp" Root Panel EPDNI Bonded Steel Washers j��y�:,�<�.r` .r�.sK�'cr �.r 's r _ .✓r,:x,r,�.C�tK"ir�'',rC✓;;r�v�+^rv',':% '� „*,rr aft- "n 5 Al �3 �'1�`fE tl:ti � r t���a!s� li��.�t�aw,^�u�,-���.✓��t:�.z,��,,;�,71).. �:��a tia� �.rt°��, ��..r_�t�u�'3:t=s,`�ixy�.iy Deck: -15132"or greater Plywood,or -Wood plank Fasteners- -15 Hex-Head Screws With 5V-Crimp" Roof Panel EPDNl Bonded Steel Washers fl! �i ^`" n Ja 1 XL A iv tl' 1t� 11 1Y" US JiSt it tsti ��it ti Fl3?s!1r tU b: IA ';,-. I!11 it Deck: -15132"or greater Plywood,or -Wood plank