Loading...
HomeMy WebLinkAboutProduct Approval U a LIMM BCIS Home l Log In l User Registration l Hot Topics l Submit Surcharge l Stats&Facts l Publications I Contact Us l BCIS Site Map l Links l Search l Florida � 4 `Product Approval ,L•eL1ja USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail I — FL# FL16177-R2 Application Type Revision MAR 1 7 21320 Code Version 2017 Application Status Approved i S'(. Lucite County, P-mi fitting Comments Archived 15 Product Manufacturer Custom Window SystenRM . ILE C0009 Address/hone/Email 100 SW 44th Avenue Ocala, FL 34474 (352)368-6922 Ext 291 jlathrop@cws.cc Authorized Signature Kevin Pine kpine@cws.cc Technical Representative ]ay Lathrop Address/Phone/Email 1900 SW 44th Ave, Ocala,FL 34474 (352) 368-6922 Ext 291 jlathrop@cws.cc Quality Assurance Representative Arturo Monteverde Address/Phone/Email 1900 SW 44th Ave Ocala, FL 34474 (352)368-6922 Ext 221 amonteverde@cws.cc Category Windows Subcategory Single Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer L� Evaluation Report-Hardcopy Received Florida_Engineer or Architect Name who developed the Lucas A.Turner Evaluation Report Florida License PE-58201 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 07/21/2020 Validated By Steven M.Urich, PE U Validation Checklist-Hardcopy Received Certificate of Independence FL16177 R2 COI EvaiReport812C.odf Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA/101/I.S.2/A440-08 2008 ASTM E1886-05 2005 ASTM E1996-09 2009 PA TAS 201/202/203 1994 Equivalence of Product*Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 09/28/2017 Date Validated 09/29/2017 Date Pending FBC Approval 10/03/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description 16177.1 SH-8100 PVC Single Hung SH-8100 PVC Single Hung Impact Resistant window. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16177 R2 II CWS-812C.pdf Approved for use outside HVHZ:Yes Verified By: Lucas A.Turner 58201 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: +70/-70 Evaluation Reports Other:SH-8100 PVC Impact, no sill anchors required. Safety FL16177 'R2 AE EvalReport812C.pdf glazing required on outer lite above 30 ft. in HVHZ. Glass Created by Independent Third Party:Yes complies to ASTM E1300-04. Back Mext Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Priya Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: "IMI-9, ® eCMrl: M Credit Card Safe SINGLE HUNG - LARGE MISSILE IMPACT GENERAL NOTES:1.THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED V � • TO COMPLY WITH THE FLORIDA BUILDING CODE(FBC),CURRENT WINDOW SYSTEMS EDITION INCLUDING THE HIGH VELOCITY HURRICANE ZONE(HVHZ)AND 1900 SW 44TH AVE. IS RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED OCALA,FLORIDA 34474 IN ASTM E 1996 PER THE FBC. WWW.CWS.CC 2.GLAZING OPTIONS:(SEE SHEET 2) 53 1/8"-MAX.OVERALL FLANGE WIDTH 3.CONFIGURATIONS:"ODC. 8100 PVC 517/8"MAX.UNIT WIDTH SINGLE HUNG 4711/16"GLASS DLO 4.DESIGN PRESSURE RATING: IMPACT -NEGATIVE DESIGN LOADS BASED ON,TESTED PRESSURE AND GLASS TABLES ASTM E-1300-04e01/09. A -POSITIVE DESIGN LOADS BASED ON,TESTED PRESSURE,WATER INFILTRATION TEST PRESSURE AND GLASS TABLES F a w G w o w -- -- -- ASTM E-1300-04e01/09. z w o D Lu ZOz <OLU 63" _ __ I 5.ANCHORAGE:THE 331/3%STRESS INCREASE HAS NOT BEEN USED L F W Z��2 MAX IN THE DESIGN OF THIS PRODUCT.SEE SHEET 6 FOR ANCHOR Z z x 2¢of w 0 0 OVERALL I I DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD 0 O I-O cj¢x F..w FLANGE HEIGHT ANCHOR CALCULATIONS. o Z v~)cf) z CL z F _� B O I B 2613/16• 6.PRODUCT APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE ¢ Z U 0 z 0 w O GLASS NOT REQUIRED. Of LCL) H F-F Z I I 7.ALL FRAMES AND VENTS FULLY WELDED.SMALL JOINT SEAM SEALANT w 0 0 o w m w MAX4" I I USED AT FIXED MEETING RAIL AND JAMB. nx ?=a 0 O(D� HEIGHT 8UNIT .SERIES/MODEL DESIGNATION SH 8100. w x 1.-a W�w w a I- D 9.THE DESIGNATION X AND O STAND FOR THE FOLLOWING: I I I X=OPERABLE SASH,O=FIXED SASH V�PNDREW'i!A. 303/16° I I ���p`?.•'�OENg'•G�Q��� 10.SECTION CALLOUTS APPLY TO ALL ELEVATIONS IN A SIMILAR MAX. 26 7/6' :JVD• �' F ��y SASH `, I GLASS LOCATION. ��� No 56201 :9: HEIGHT X I DLO g 11.EXTERNAL WEEP SLOT=1/4"x 1-1/4"LOCATED 4"FROM BOTH ENDS. D �: STATE OF :41 4 6 •R I I �iy�� .L p Rk I 'Bill NA ito, - \ WINDOW SYSTEMS YSTEPS 1900 SW 44TH AVE. OCALA,FLORIDA 34474 WW W.CWS.CC 8100 PVC SINGLE HUNG IMPACT a z 3 azo F ❑WO woo -1 0Lu o ; uU)z>-oir§m 7/8"OVERALL INSULATED GLASS 718"OVERALL INSULATED GLASS O O F=-O Q Q=OF o 1/8"ANNEALED ORTEMPERED 1/8"ANNEALED OR TEMPERED V z 1 Z z~ D. z p 1—ZZ)L)m 7/16"AIRSPACE 7/16"AIRSPACE Z O W Z r G�pw-=0? 5116"LAMINATED GLASS 5116"LAMINATED GLASS 4 2 F-V O to 1/8"ANNEALED 118"ANNEALED ZCD w m o w U)w co .090"PVB INTERLAYER BY DUPONT .090"PVB INTERLAYER BY DUPONT 4. CIL O wr0 o-OxLuU) 118"ANNEALED 1/8"ANNEALED (L F- 0_ O: d QUANEX DURASEAL QUANEX DURASEAL ,��puuhrpr IG SPACER IG SPACER ��0 �OREW 11,E 4 PURFECT GLAZE°H"OR SIKAFLEX 552 4 PURFECT GLAZE"H"OR SIKAFLEX 552 ,G�9 4 c ENSU Z— r� �: No 58201 14 1/2"GLASS BITE 14 1/2"GLASS BITE *7 48 48 :9 STATE OF .•+I!/ O• 4L;' 3 �6`'�40 R 71 q o SASH LITE 9/22/2017 FIXED LITE LUCAS A.TURNER,P.E. FL PE#58201 1239 JABARA AVE. NORTH PORT,FL 34288 PH.941-380-1574 SHEET DESCRIPTION: GLAZING DETAILS DRAWN BY: DATE: BAT 06/18/12 DWG#: REV.: CWS-812 C SETTING BLOCKS PER FBC 2411.3.3.1 SCALE' SHEET 1:1 2 OF 6 INTERIOR WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA,FLORIDA 34474 45 3 1 3 13 3 3 4 wwwZwS.Cc ,T- -- 8100 PVC 70 SINGLE HUNG IMPACT u)w0b W�c w 14 W z0Z w 3 0Cry O� LL 1<--w 3 14 54 14 6 66 63 19 4 z Z=2<ww00 0 0 ,3 X:0 < �-w SECTION B-B C 0 t;Z CL.-M m 54 a zaw NOTE:LEFT SIDE SHOWS FIXED SECTION VIEW, z 0 0(6 =)C)— < p:Z MZO,u RIGHT SIDE SHOWS SASH SECTION VIEW. <§E LCL)w 0=0 z M gfl-8k=Z C6 M f<z OCI iE LL Ln a)Q w(0 Lu 14 39 z uj U)w>- 0 �- a. W�o R M a. R-0 co 3z w— X w CL 1 3 INTERIOR &P�iDRE.. 6 408 W 9 ........cj No 5132071 -P-Z STATE OF N 14 53 fit$IIIWiee 65 10 66 6 3 3 1 3 9/22/2017 LUCAS A.TURNER,P.E. 73 FL PE#58201 1239 JAARA AVE. 30 NORTH PORT,FL 34288 PH,941-380-1574 SHEET DESCRIPTION: SECTION A-A SECTION VIEWS DRAWNBY: -6A—TE' BAT 06/18112 NOTE: ITEMS NOT SHOWN FOR CLARITY: DWG#: 20.26-26,36-37,44,51-52,55-56,64,67-68 CWS-812 c -§C—ALE' SHEET 1:2 PARTS LIST FRAME CORNER —����� REM PART# DESCRIPTION VENDOR MATERIAL CONSTRUCTION ®)yj}f]�VaVd 1 H-6031 Main Fr.,SH,w/Fig.,PVC,Head Mikron Vinyl 31/8^ ��!(Yll W/LV an Irl(n��/fl, VbIPdDOVd SYSTEMS 2 H-6031 Main Fr.,SH,w/Fig.,PVC,Sill Mikron Vinyl 1 15116' 3 H-6031 Main Fr.,SH,w/Fig.,PVC,L.Jb. Mikron Vinyl 1 f--23116" OCALAA,1900 LTH AVE. 2 CAFLORIDA 34474 4 H-6031 Main Fr.,SH,w/Flg.,PVC,R Jb. Mikron Vinyl 3 8 WWW.CWS.CC 6 S-1577 Impact Hook Keymark Alum 4 10 8 H-6027 Sash Meet.Rail,PVC Mikron Vinyl 211/16" 15/8" [—=:j 1 518• i� 9 H-1497 Reinf.Sash Meet.Rail Keymark Alumo 1/16^ 1/16„ 1/16 LD 8100 PVC 10 H-6028 Sash Bottom Rail,PVC Mikron Vinyl }— C(ALL SIDES 12 H-6004 Sash Side/Top/Bot.Reil Mikron Vinyl 1:8 ) SINGLE HUNG 13 S-1498 Reinf.S.B.R./S.S.R IMPACT 14 S-6064 Glz.Ed.,7/8" Mikron Vinyl PVC FRAME FLANGE-6031 PVC SASH BTM.RAIL-6028 PVC SASH TOP RAIL-6027 18 S-6013 Scm.Adapt.,w/Nib,PVC,Horiz. Mikron Vinyl ¢ Z � ¢z p 19 S-6014 Scm.Adapt.,PVC,Vert. Mikron Vinyl 1 1/2• Fcc ❑W O Q W❑o 20 S-6029 Sash Stop/Filler,PVC,Vert. Mikron Vinyl3 w Z 0 Z It k z H 23 H-1699 Reinforcement,SBR Keymark Alum 7/B' 13/16"-i---y 1 71 ❑ IQ-w�i z O 3 g 24 P-2190 Balance BSI 9116 Z Z M�¢W W O O O OF-O ¢=Fro 25 P-3059 Sash Cam,PVC BSI Plastic 73 U U rn 1-O D.F rn D. 1 518 2 1/8' 1116 FIXED MEETING RAIL ❑ Z-❑Z Z 26 P�046 Take Out Clip BSI SS 1/16 n ❑-.-:)L)- 27 m �I SCREWED Z U' 1,- 27 P-3783 Lock,Impact,PVC Interlock U 1/16" OUTERFRAME ¢ �Z w��O t1 z 28 P1}D69 Keeper,Impact,PVC Interlock Zamac 1;8 Y ¢�O W F-F O- REINF.,IMPACT HOOK-1112 F-U Z N 30 P-3215 Weep Cover wl Flap Gaer Plastic a o U>) 2❑ O 2 32 P-3429 Wstp.,0.270 x.187 back FlnSeal,Gray Ultrafab PVC SASH SIDE RAIL-6004 FIXED RAIL-1836 0 0 W ro❑O ul Cf)Lu 37 P-0638 #8 x 2-1/2 PH Mod.Truss,Type A,TEK 2 Fastenal Steel 0. =a W O 38 P-3768 #8 x 0.625 Ph PH SMS Hub City Steel 1 5/1 s^ s/1s• O W F-0 w= U) 39 P 4051W#8 x 1.250 Ph FH TEK,Wht. Hub City Steel 112^ 1 1/8• 11/8-1 a F- o aW 40 P-4264W#8 x 314 FH PH w/#8 Head,TEK,Wht. Hub Cit Steel 0 5/16" City `tpwuurpr 44 P$342 Seem Sealer,SM 5504 Schnee y 7/1 111 s^ 1 5116" 1/16'9 �. .`PLIC...... :. 45 P-3752 Ca Plug,1/2"Hole M&M N Ion N `' 5 '0 47 P-3438 Sikaflex 552 or Purrect Glaze"H" Sika/Henkel 1116' .J;' PVC SCREEN CATCH-6013 PVC FIXED RAIL COVER-6063 PVC SCREEN SUPPORT-6014 :�: No 58201 11 48 P-3352 Set.Blk.,BS Dur.,1/8"x 5/8"x 2"Lg. F.Lowe Rubber PVC SASH STOP-6025 51 P-3881 Temporary Lbl.(NFRC/DP) = 52 P-3613 CWS Lbl.(logo) Pro Label 3/4" 1/4' %9"; STATE OF :ww 53 Sash SEE SHEET 2 GLASS - 314° %O•. 54 Fixed SEE SHEET2 GLASS 3116^ 3 lr-+ 14 ������5.�(......R 56 P-3281 Spacer Duraseal T 13 15/U 1/16" L 1/1s^ 711' � N 62 P-3218 Screen Frame,Horiz. Allmetal Alum 1/16° 63 P-3218 Screen Frame,Vert. Allmetal Alum REINF.S.B.R./S.S.R.-1498 REINF. BTM RAIL-1699 REINF.TOP RAIL-1497 PVC GLAZING BEAD-6064 64 P-a321 Screen Frame Comer Key Allmetal Plastic 65 P-3581 Screen Cloth,18 x 16 Fiberglass Betterwe Fiberglass y� 66 P-3228 Screen Spline,.155 Dia.,Elk. Dapa Vinyl 67 P-3029 Screen Pull Tab Summit Alum 9/22/2017 68 P-3033 Screen Spring,SS FI.Screen SS 70 P-3113 Screw Support for PVC T.Plastics Nylon LUCAS A.TURNER,P.E. 71 H-1836 Alum.Fixed Rail 1 Keymark Alum 0 3/16" FL PE#58201 72 S-6063 Cover,Fixed Rail MikronVinyl O 1239 JABARA AVE. 73 S-1112 Reinforcement,Impact Hook Keymark Alum PH.941-380-1574 NORTH PORT,FL 34288 74 P�l 1#8 x 1/2",Pan Head,TEK Fastenal Steel it5/16" 1/2" _ SHEET DESCRIPTION: LINE ITEMS NOT USED: s 5" 3116 � 3 BOM AND EXTRUSIONS 5,7,11,15-17,21-22,29,31,33-36,41-43,46,49-50,55,57-61,69 0 7/le 1116" �— �� DRAWN SCREW SUPPORT-3113 IMPACT HOOK BAT 06/18/12 DATE: S-1577 -UW—G#. REV.: CWS-812 C NOTE:ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED. SCALE: SHEET 1:2 4OF6 6'MAX.(TYP.) 17"MAX.O.C.(TYP.) WINDOW SYSTEMS 1900 SW 44TH AVE. 6"MAX(TYP.) OCALA,FLORIDA 34474 -- -- -- WWW.CWS.CC I I SEE NOTE 2 - 8100 PVC 10 1/2" I I MAX O.C. SINGLE HUNG (TYP-) INSTALLATIONL O INSTALLATION ANCHOR(TYP.) I I Q � ¢Z0 I I F Ow0 Qw0W z wJ❑ o r w Z O z � _z F Lmrc way O OF-Od2=0W 4'(TYP.) I I O z0, 7ZZ1-DU) I I Q 00, ZO WnZ OLLO < 0WOFOz Y z 101/ /\ w O��aiS)3:2Owu)w MAX.O.C. LL rn w (TYP.) d z=a (ro�cn I I _~w w � Wo I I a a W a p10RE.. hi (TYP.) NO ANCHORS REQUIRED IN SILL~` ��� .J:• No 58201 •:-:P ANCHOR LAYOUT-(FLANGE)'--,, 'b' :a-C :9 STATE OF 14U �O R 10 NOTES: 1.INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION.NO ANCHORS REQUIRED IN SILL. 2.SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX.ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16"IS PRESENT. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER.WOOD SHIMS ARE NOT ALLOWED. Z 3.ANCHOR TYPE,SIZE,SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS,SEE TABLE 1,SHEET 6. 9/22/2017 4.ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST LUCAS A.TURNER,P.E. BE PROTECTED TO PREVENT REACTION. FL PE#58201 1239 JABARA AVE. 5.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM NORTH PORT,FL 34288 SPECIFIED IN TABLE 1,SHEET 6. PH.941-380-1574 6.ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS,EMBEDMENT SHALL BE BEYOND WOOD BUCKS,IF USED,INTO SUBSTRATE. SHEET DESCRIPTION: INSTALLATIONS TO SOLID CONCRETE OR GROUT-FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND THE SUBSTRATE. ANCHOR SCHEDULE AND INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. NOTES 7.A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS:3"FOR MASONRY,1"FOR WOOD AND METAL. DRAWN BY: DATE: BAT 06/18/12 8.WOOD OR MASONRY OPENINGS,BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. DWG#: Rev.: SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET,SHEET 6. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. CWS-812 C 9.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: SCALE: SHEET FMA/AAMA 100(FIN WINDOWS),FMA/AAMA 200(FLANGE WINDOWS), FMAANDMA 250(BOX WINDOWS),FMA/AAMA/WDMA 300(EXTERIOR DOORS) 1:15 5 OF 6 TYPICAL HEAD ANCHORAGE �fpv�® •�f(¶` MIN.EMBEDMENT WINDOW SYSTEMS MIN.EDGE DIST. SEE TABLE 1 SUBSTRATE SEE TABLE 1 BY OTHERS 1900 SW 44TH AVE. 114"MAX.SHIM SEE TABLE 1 OCALA,FLORIDA 34474 SUBSTRATE BY OTHERS WWW.CWS.CC SEE TABLE 1 MIN.EMBEDMENT PERIMETER SEALANT SEE TABLE 1 MIN.EDGE DIST. 8�OO PVC BYINSTALLER SEE TABLET INSIDE AND OUT SINGLE HUNG INSTALLATION ANCHOR SEALANT BEHIND SEE TABLE IMPACT FLANGE BY INSTALLER 114"MAX.SHIM Q Z � QZ3: F- O WO QW❑6 Z WJ❑ W ZOZ W_�H PERIMETER SEALANT LL F-W Z F-X 2 2 BYINSTALLER Z Z 2�Q K W O p O OF-O Q INSTALLATION ANCHOR INSIDE AND OUT U U u)�Z D-F-U)d SEE TABLE 1 SEALANT BEHIND Z ZO ❑—Z I.-:) U) FLANGE BY INSTALLER Q Z U U Z OIL U F —D-2O Z W 2�pFW-F-FF--z CONTINUOUS DOUBLE 3/16"BEADS OF / n HORIZONTAL SECTION U uj E U1600 SEALANT AROUND 6 TYPICAL JAMB ANCHORAGE p >❑�O� PERIMETER TREMGLAZATALL INDICATED POINTS w z y W O o h FW- BETWEEN FRAME AND BUCK BY INSTALLER. D. =D- O U O WF-O D.2�} 1/4"MAX.SHIM d F- D- w a u) SEALANT BEHIND FLANGE BY INSTALLER `�����PNOREL'y�T.,�� �?.�.......... G E tJ SF G�Qti�,,r PERIMETER,'EALANT :J; BYINSTALLER MIN.EMBEDMENT SEE TABLE 1 No 58201 %?�G INSIDE AND OUT %13'. STATE OF SUBSTRATE BY OTHERS �iO,n'.,R SEE TABLE 1 MIN.EDGE DIST. �i�Fs".(O R SEE TABLE ���3/•"� •• A VERTICAL SECTION �q�+ONA„���� 6 TYPICAL SILL ANCHORAGE 9/22/2017 TABLE 1:APPROVED INSTALLATION FASTENERS LUCAS A.TURNER,P.E. SUBSTRATE TYPE ANCHOR TYPE MIN.EMBEDMENT MIN.EDGE DIST. FL PE#58201 PERIMETER SEALANT 1239 JABARA AVE. CONCRETE(2.0 KSI MIN.) 3/16"ITW TAPCON 1-1/2" 1-118" BYINSTALLER NORTH PORT,FL 34288 HOLLOW OR GROUT-FILLED CMU(117 PCF MIN.) 3/16"ITW TAPCON 1" 2" INSIDE AND OUT PH.941-380-1574 C HORIZONTAL SECTION CONCRETE(2.85 KSI MIN.) 3/16"ELCO ULTRACON 1" V 6 BOX FRAME INSTALLATION SHEET DESCRIPTION: GROUT- 3 _ 1-1/4° 2-1/2" HEAD AND SILL SIMILAR FOR BOX INSTALLATION 3116"ITW TAPCON INSTALLATION DETAILS 2X MIN.SOUTH INE(G=0.55) -3/8" 7/8" OR ELCO ULTRACON FLANGE REMOVAL NOTE:PARTIALLY OR FULLY REMOVING THE FLANGE, 2XMIN.SOUTHERN PINE(G=0.55) #10 WOOD SCRE 1-3/8° 7/8" UP TO AND INCLUDING A BOX-FRAME APPLICATION IS ACCEPTABLE PROVIDED: DRAWNDATE: 16 LTI KW IK-FLEX OR ITW FULL THREAD BAT 06/18/12 (33 KSI YIELD MIN) TEKS SELF-DRILLING SCREW THRU 0.060" 7/16" MIN.1/4"FILLET OF CONSTRUCTION-GRADE ADHESIVE CAULK IS APPLIED DWG#: REV.: INSIDE AND OUT,FULL PERIMETER,BY INSTALLER. CWS-812 C 118"ALUM.(6063-T5 MIN.)OR #10 GRADE 5 SELF-TAPPING/ FULL THREAD PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS 1/8"STEEL(33 KSI MIN.) DRILLING SCREW THRU 0.125' 7116 SHOWN FOR FLANGE WINDOWS. SCALE: SHEET 1:2 6OF6