Loading...
HomeMy WebLinkAboutProduct Approval BCIS Home i Log In User Registration I Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search i Florida Product Approval 9 USER:Public User Pl - r �roxtr aei &t`eswnl�.tanw Product Approval Menu>Product or Application Search>Application List>Application Detail F� i Re Application Type Revision Code Version 2017 Application Status. Approved Comments Archived Ci Product Manufacturer Gulf Coast Supply&Manufacturing.Lr, Address P one a 2 9th Street Horseshoe Beach,FL 32648 (352)498-0778 lnfo@gulfcoastsupply.com Authorized Signature Eng David info@gulfcoastsupply.com Technical Representative David Eng Address/Phone/Email 14429 SW 2nd PI Ste G30 Newberry,FL 32669 3/R (352)498-0778 info@gulfcoastsupply.com L, Ole Quality Assurance Representative David Eng Address/Phone/Emall 14429 SW 2nd PISte G30 ®� Newberry, FL 32669 G®® ��®f (352)498-0778 1 o o ®CC david.eng@gulfcoastsupply.com ,1a Category Roof�in Sumttr Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Daniel S.Kuhn Evaluation Report Florida License PE-75519 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 04/12/2024 Validated By Locke Bowden P.E. 0 Validation Checklist-Hardcopy Received Certificate of Independence FL11651 R3 COI Cert of Independence 2017-10-09.pdf Referenced Standard and Year(of Standard) Standard Year FM 4471 1992 TAS 100 1995 TAS 110 2000 TAS 125 2003 UL1897 2012 UL 580 2006 �tiii� •_ � -, �. � .'. _ ,� - � .= _ _ � '• ` _ � . clip spacing.Install per manufacturers details. For use in HVHZ FL11651 R3 AE FL11651 5 R3 lin 032VersaLoc SR 16 15- Zones. 32Plywood HVHZ-signed.pdf Created by Independent Third Party:Yes 11651.E 1.5"24ga.Gulf Snap 1.5"Gulf Snap 24ga. 16"Wide Roof Panel over 15/32"Plywood. Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL11651 R3 II FL11651 6 R3 Metal Roof Panel Detail- Approved for use outside HVHZ:Yes glgngd•pdf Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519 Design Pressure: +N/A/-116.OPSF Created by Independent Third Party:Yes Other:-86.0 psf @ 24"o.c.clip spacing.-108.5 psf @ 12"o.c. Evaluation Reports clip spacing.-116.0 psf @ 6"o.c.clip spacing.Install per FL11651 R3 AE FL11651 6 R3 1.5 24GulfSnap 16 15- manufacturers detals. For use in HVHZ Zones. 32Plywood HVHZ-signed.pdf Created by Independent Third Party:Yes 11651.7 1.5"24ga.VersaLoc 1.5"VersaLoc min 24ga. 16"wide Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11651 R3 II FL11651 7 R3 Metal Roof Panel Detail- Approved for use outside HVHZ:Yes signed pdf Impact Resistant: N/A Verified By: Dan Kuhn,P.E.75519 Design Pressure:+N/A/-123.5PSF Created by Independent Third Party:Yes Other:-59.75 psf @ 24"o.c.clip spacing.-123.5 psf @ 12" Evaluation Reports o.c.clip spacing.Install per manufacturers details. For use in FL11651 R3 AE FL11651 7 R3 1.5 24VersaLoc 16 IS- HVHZ Zones. 32Plywood HVHZ-sianed.pdf Created by Independent Third Party:Yes 11651.8 2"24ga. MegaLoc Min 24 Ga. 2"MegaLoc 18"wide Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL11651 R3 II FL11651 8 R3 Metal Roof Panel Detail- Approved for use outside HVHZ:Yes signed.pdf Impact Resistant: N/A Verified By: Dan Kuhn,P.E.75519 Design Pressure: +N/A/-108.5PSF Created by Independent Third Party:Yes Other:-71.0 psf @ 24"o.c.clip spacing.-108.5 psf @ 12"o.c. Evaluation Reports clip spacing.Install per manufacturers details.Not for use in FL11651 R3 AE FL11651 8 R3 24VersaLoc 18 IS- HVHZ Zones. 32Plywood NonHVHZ-signed.pdf Created by Independent Third Party:Yes 11651.9 24 Ga.Gulf Lok Min 24 Ga. Gulf Lok 16"Wide over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL11651 R3 II FL11651 9 R3 Metal Roof Panel Detail- Approved for use outside HVHZ:Yes signed pdf Impact Resistant: N/A Verified By.: Dan Kuhn,P.E.75519 Design Pressure: +N/A/-96.7PSF Created by Independent Third Party:Yes Other:-81.75 psf @ 10-1/4"o.c.fastener spacing.-96.76 psf Evaluation Reports @ 5-1/8"o.c.fastener spacing.-121.75 psf @ 5-1/8"fastener FL1•1651 R3 AE FL11651 9 R3 24GulfLok 16 15- spacing.-161 psf @ 5-1/8"fastener spacing.Install per 32Plywood NonHVHZ-signed.pdf manufacturers details. Not for use in HVHZ Zones. Created by Independent Third Party:Yes 11651.10 24 Ga.Gulf Seam Min 24 Ga. Gulf Seam 16"Wide Roof Panel over 1x4 Wood Purlins over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL11651 R3 II FL11651 10 R3 Metal Roof Panel Detail- Approved for use outside HVHZ:Yes signe .pdf Impact Resistant:N/A Verified By: Dan Kuhn, P.E.75519 Design Pressure:+N/A/-93.5PSF Created by Independent Third Party:Yes Other:-93.5 psf @ 18"o.c.Install per manufacturers details. Evaluation Reports Not for use in HVHZ Zones. FL11651 R3 AE FL11651 10 R3 24GulfSeam 16 1x4 15- 2Pywood NonHVHZ-signed.pdf Created by Independent Third Party:Yes 11651.11 24 Ga.Gulf Seam Min 24 Ga. Gulf Seam, 1 3/4"Snap Lock, 18"Wide Roof Panel over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL11651 R3 II FL11651 11 R3 Metal Roof Panel Detail- Approved for use outside HVHZ:Yes signed pdf Impact Resistant:N/A Verified By: Dan Kuhn,P.E.75519 Design Pressure: +N/A/-108.5PSF Created by Independent Third Party:Yes Other:-69.25 psf @ 24"o.c.clip spacing.-108.5 psf @ 12" Evaluation Reports o.c.clip spacing.Install per manufacturers details. Not for use FL11651 R3 AE FL11651 11 R3 24GulfSeam 18 15- in HVHZ Zones. 32PIy_wood NonHVHZ-signed.pdf Created by Independent Third Party:Yes 11651.12 26 Ga.5V Crimp Min 26 Ga. 5V Crimp Roof Panel over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL11651 R3 II FL11651 12 R3 Metal Roof Panel Detail- r ... � �)� Y��. � f ... ':f r � � i ill l.. �. �. _. "' i ;.t' � � 1. ... + .. .__ tY 1. .... .. .. .1. . . t .�f 1 . .. ,r � � 1. r �. � ,.�-;17' � � �. J .ri.' ,. -. e .,. .1.... ,.i. �: .. � ' K.t is ' � ��1' � 1. t': i.t• .. ,.. � .l r ��i' �— _ � �J yl,.. � ,`, r ., ..... ® ® s ® Gulfc&M SUPPLY & MANUFACTURING P 5-N., Al, • GA. 5VCRIMP ROOF PANEL OVER • • FLORIDA PRODUCT APPROVAL N(•i 11651.13 R TM TYPE 1 FASTENER PATTERN (1 ) #9-15 x 1 -1/2" HWH w/Sealing Washer 12 7 12" At Panel — La � p TYPE 2 FASTENER PATTERN (1 ) #9-15 x 1 -1/2" HWH w/Sealing Washer 211 � 9.5" 1" 9.511 2111 . +,+IIIIIIfI,�� AJEL S. h- ••�,�c�Ns�:yy No. 75519 = STATE OF 'Q ��O R 10 P •'�1�%�.•` J, NA L 'E ++`10/05/201 j FL#11651.13 R3•OCTOBER 5,2017 �J -��a..+i... iC 14%� � 4 :�: ` ''•i Y . - .. 9:, .. $'.. � . • f 7 1 ' .'. �. .. � � • . ld..v r. .� � _ �• , � � a e', ' �• • � �- •..� , t . � . � . . � � . . . . . � . Gulf '�WoaRt SUPPLY & fiflANUFACTURING 26 GA. 5VCRIMP ROOF PANEL OVER • • FLORIDA PRODUCT APPROVAL NO. 11651.13 R3 TM Product Evaluation Report GULF COAST SUPPLY& MANUFACTURING, LLC. 26 Ga. 5V Crimp Roof Panel over 15132"Plywood Florida Product Approval #11651.13 R3 Florida Building Code 2017 Per Rule 61 G20-3 Method: 1 -D Category: Roofing Subcategory: Metal Roofing Compliance Method: 61 G20-3.005(1)(d) NON HVHZ Product Manufacturer: Gulf Coast Supply & Manufacturing, LLC. 14429 SW 2nd Place, Suite G30 ttltlll/t Newberry, FL 32669 �.•'A�rUEL S, Engineer Evaluator: No. 75519 Dan Kuhn, P.E. #75519 - Florida Evaluation ANE ID: 10743 STATE OF :Q: Validator: R Locke Bowden, P.E. #49704 �'S'1VAL 9450 Alysbury Place Montgomery, AL 36117 Contents: Evaluation Report Pages 1 - 5 FL#11651.13 R3•OCTOBER 5,2017 ® REP.bRT. ENGINEERING,KUHN . J x v } -3'. » 'rK� 'Coi'�t ® ® D . • . . Gulf SUPPLY & MANUFACTURING r I� 16 N b 2 GA. 5VCRIMP ROOF PANEL OVER 15/32" PLYWOOD FLORIDA PRODUCT APPROVAL NO. 11651.13 113 TM Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2. Product Description: 5V Crimp Roof Panel, 26 Ga. Steel, 24" Coverage, through fastened roof panel with fasteners in the panel flat over minimum 15/32" plywood decking. Non Structural application. Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2017 Section 1507.4.3. Paint Finish Optional Yield Strength: 80.0 ksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2017, Section 1507.4.3. Panel Dimension(s): Thickness: 0.018" Minimum Width: 24" Coverage Rib Height: 3/a" Major Rib Panel Fastener: #9-15x1.5" with sealing washing in the.flat of the panel or approved equal, 1/4" minimum penetration through plywood. Corrosion Resistance: Per Florida Building Code 2017, Section 1506.6, 1507.4.4 Substrate Description: Minimum 75/32" thick, APA Rated plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/Florida Building Code 2017. Design Uplift Pressures: Table"A" a i um Total Upli Osign ressure. [9`4`2�5s 13,1 Q nsf Fastener Pattern 12"-12" 9.5"-2"-9.5" Fast deter Pa`i -r, LL g Design Pressure includes a Safety Factor;2.0. FL#11651.13 R3•OCTOBER 5,2017 ! . . • ENGINEERING,KUHN ] A ]:Wx. SUPPLY & MANUFACTURING ® � l 26 GA. 5VCRIMP ROOFOVER • • FLORIDA PRODUCT APPROVAL NO. 11651.13 R3 TM Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 61 G20-3. Performance Standards: The product described herein has demonstrated compliance with: • UL 580-06-Test for Uplift Resistance of Roof Assemblies • UL 1897-12 - Uplift Test for Roof Covering Systems. Reference Data: 1. UL 580-94/ 1897-98 Uplift Test Force Engineering &Testing, Inc. (FBC Organization #TST-5328) Report No. 117-0053T-05 & 117-0331 T-08 2. Certificate of Independence By Dan Kuhn, P.E. (FL#75519)@ Kuhn Engineering, LLC (FBC Organization #ANE ID: 10743) Test Standard Equivalence: 1. The UL 580-94 test standard'is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-12 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61 G20-3.005(3)for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per Manufacturer's recommended details. Underlayment: Shall comply with Florida Building Code M17 section 1507.1.1. Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear Diaphragm values are outside the scope of this report. FL#11651.13 R3•OCTOBER 5,2017 D D • ® 0 ` ® D r s '� . . .. - - x�` :. .;;. .. .:# .. }-° - � ., r� 4 .. u 2 t ...# � � .r./ x < - � � .{, ,� a�:. Wit. _ ... _ � r �A'4�'.� M,,, M'.e, �, � ".. ,.. "9 x �� �... ..'� .. SUPPLY & MANUFACTURING Gull 'Coi4�t ' T-5r V -C- F: 4-i NW, - P ROOF PANEL OVER . . . FLORIDA PRODUCT APPROVAL NO. 11651.13 R3 TM Design Procedure: For roofs within the parameters listed on the load table, fastening pattern must at a minimum meet those listed for the applicable wind zone. For all roofs outside the parameters listed on the load table, design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design.The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this product in High Velocity Hurricane Zone. FL#11651.13 R3•OCTOBER 5,2017 ' �10 , G6iCoak SUPPLY & MANUFACTURING 26 GA. 5VCRIMP ROOF PANEL OVER • • i FLORIDA PRODUCTAPPROVAL TM ENGINEER LOAD TABLE:26 Ga. 5VCrimp Roof Panel over 15/32"Plywood e�Ln � 'fit ',. '.+""d °�'`.�."° Bu�JcingsfauingaR of,Mean *xeghts20,0RoofSfbpe2 �sf�2 " 12 /k1{"ZGableorHipRoc�fllV�r�tlSp4e 180rn h; E`a ure f31sk Ca%NjR- f n o ed Bu dingsF ed�on�Fio da Br�lidi Cade 0=17 Y - .� .�.�_-__z3.a �9 `- 120 130 140 150 160 170 180 WIIND FASTENER SUBSTRATE SPEED (MIN.1/4" (MIN.15/32") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER Penetration) SPACING SPACING SPACING SPACING SPACING SPACING SPACING 3F � k i�y, x''#E�X ' �a s#�ZOi�lE 1 t#9 15 1 5 �t�P�l 16 NPEw1�16,"c�PE 1_7 16 ?Tcl'PE 1 t 16 H PE-. t 16k n,P,E 1 w16,,TYPE i";. 16` r1f;Pl 1'r. ,- .„ .� ,. ZONE 2 #9-15X1.5" Plywood 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 g, w F.... 7 i"s r ki - ZQNE 3 #9 15x1 5" Pl` ' ood �16T�YPE�1 I67hYPE 1� 16T�Y�P�E 116xTYPE116T+YPEryg ;.`.s PE 1.)PANEL DESCRIPTION:5V CRIMP, MIN. 26 GA., GRADE 80, 24"COVERAGE. 2.)PANEL FASTENER:#9-15X1.5" HWH WITH SEALING WASHER W/MIN. �/4" PENETRATION. 3.)MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE:-94.25 PSF@ 16" O.C. FASTENER SPACING TYPE 1 FASTENER PATTERN, -131.0 PSF 016" O.C.,FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING. 4.)PLYWOOD DECKING: MIN.15/32"THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2017. 5.)ROOF SLOPE:ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS. 6.)LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10(KD=0.85)MULTIPLIED BY 0.6 PER FLORIDA BUILDING CODE 2017. ZONE 2 HIP ROOF ZONE a Note:Dimension(a)is defined as 10%of the minimum width of the building or --—— — — — —_ a 40%of the mean height of the roof,whichever is smaller,however,(a)cannot be less than either 4%of the minimum width of the building or 3 feet. �.\ RIDGE TYPE 1 FASTENER PATTERN --------- `.\ (1) #9-15 x 1-1/2" HWH w/Sealing Washer ZONE \� �� 12" 12" /------------------- 4- --EAVE i , At Panel Lap ZONE 2 GABLE ROOF i I TYPE 2 FASTENER PATTERN RIDGE (1) #9-15 x 1-1/2" HWH w/Sealing Washer +---------------------+ a I ZONE 1 I I �-ZONE3 VEAVE FL#11651.13 R3•OCTOBER 5,2017 • , • -.. � �l •,� 1 s•. - ` ., a i - 4 t � _ .. .. ... _ _ ... - - -- - - � _ i � f; - ' _., s` . . y � • i