HomeMy WebLinkAboutProduct Approval RECE1VF_: File Copy
MIAMI•�►DE MAR 1 7 2020 MIAMI=DADS COUNTY
e II PRODUCT CONTROL SECTION
ST. Luc � r 11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOM ItESO� miffing
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) Nvww.miamiaade.gov/building
Sun-Tek Manufacturing,Inc. REVISE®
10303 General Dr. ®
Orlando,EL 32824 CODE COMPLIANCE
SCOPE: ST. LUCOE OOU
This NOA is being issued under the applicable rules and regulations governing t� of onstruc{io�n�materials.
The documentation submitted has been reviewed and accepted by Miami-Dade Coun Product Control
Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction
(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right
to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the High Velocity Hurricane
Zone of the Florida Building Code.
DESCRIPTION: MD-CMA Skylight.
APPROVAL DOCUMENT: Drawing No. CMA-002,titled "MD-CMA", sheets 1 and 2 of 2,prepared by
Sun-Tek Manufacturing,Inc., dated May 09,2011, signed and sealed by James D. Wells,Jr.,P.E.;on October
06,2017,bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance
number and the expiration date by the Miami-Dade County Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami-Dade County Product Control Approved" or the Product Control Seal, unless
otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in
the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any
product,for sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it
shall-be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA#15-0513.05 and consists of this page 1, evidence submitted pages E-1,E-2, and E-3 as
well as approval document mentioned above.
The submitted documentation was reviewed by Hy
e my A.Makar,�P.E..,,fM.S.
023.18
MIAMI-DADE COUNTY 6 �/` J/C�2�/�.• ion No. 17-13/2023
.•... , ,,.,a Expiration Date: 03/13/2023
p� f�T zz, Approval Date: 03/15/2018
/ / Page 1
Sun-Tek Manufacturing,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#08-0110.06
A. DRAWINGS
1. Manufacturer's die drawings and sections.
2. Drawing No. CAA-002, titled "MD-CAM", sheets 1 and 2 of 2,prepared by Sun-Tek
Manufacturing, Inc., dated 09113195 and 04125195, with no revisions, signed and sealed by
Rene J. Quiroga, P.E.
B. TESTS
1. Test reports on 1)Air Infiltration Test,per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
3) Water Resistance Test,per FBC, TAS 202-94
4)Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
6)Forced Entry Test,per FBC 2411 3.2.1, TAS 202-94
along with marked-up drawings and installation diagram of Model MD-CMA Curb
Mounted Plastic Dome Skylight,prepared by National Certified Testing Laboratories,
Test Report 9210-2885-1, dated 10/31/02, signed and sealed by W. A. Davis Jr., P.E.
C. CALCULATIONS
1. Anchor calculations prepared by Product Technology Corporation on 02105103,
signed and sealed by A. Perez Maldonado, PE.
D. QUALITY ASSURANCE
1. Miami Dade Building Code Compliance Office (BCCO)
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 07-0212.01 issued to General Electric Plastics for their
"Lexan Sheet Products", approved 05/25/07, expiring on 07/17/08.
F. STATEMENT
1. Code compliance letter issued by Product Technology Corporation on 02/06/03,
signed and sealed by A. Perez Maldonado
(Evidence Submitted under NOA # 03-0401.07)
G. OTHERS
1. Notice of Acceptance No. 03-0401.07, issued to Sun-Tek Manufacturing, Inc.,
approved on 10/09/03 and expiring on 03/13/08.
2. No change letter issued by Sun-Tek Manufacturing, Inc., dated 01/02/08, signed by
James Feudner.
elmy A.Makar,P.E.,M.S.
Product Control Section Supervisor
NOA No. 17-1023.18
Expiration Date: 03/13/2023
Approval Date: 03/1.5/2018
E-1
Sun-Tek Manufacturing,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
2. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#11-0601.04
A. DRAWINGS
1. Drawing No. CMA-002, titled "MD-CMA", sheets 1 and 2 of 2,prepared by Sun-Tek
Manufacturing, Inc., dated May 09, 2011, signed and sealed by.Tames D. Wells, Jr.,
P.E., on May 08, 2012.
B. TESTS
1. Test reports on 1)Air Infiltration Test,per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4)Large Missile Impact Test per FBC, TAS 201-94
S) Cyclic Wind Pressure Loading per FBC, TAS 203-94
6) Forced Entry Test,per FBC 2411 3.2.1, TAS 202-94
along with marked-up drawings and installation diagram of Model MD-CMA Curb
Mounted Plastic Dome Skylight,prepared by National Certified Testing Laboratories,
Test Report No. NCTL-210-3859-1, dated 03104113, signed and.sealed by Gerard J
Ferrara, P.E.
C. CALCULATIONS
1. Anchor calculations prepared by J&L Wells Consulting LLC, 19 pages, dated
0311912013, signed and sealed by James D. Wells, Jr., P.E.
D. QUALITY ASSURANCE
1. By Miami-Dade County Department of Regulatory and Economic Resources.
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENT
1. Florida Building Code, 2010 Edition, compliance letter prepared by J&L Wells
Consulting LLC, dated 0412512012, signed and sealed by James D. Wells, Jr., P.E.
3. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL 415-0513.05
A. DRAWINGS
1. Drawing#CMA-002, titled "MD-CMA", ,sheets 1 and 2 of 2,prepared by Sun-Tek
Manufacturing, Inc., dated 05109111, signed&sealed by James D. Wells, Jr., P.E., on
05108112,
B. TESTS
1. None.
C. CALCULATIONS
1. None.
elmy A. Makar,P.E.,M.S.
Product Control Section Supervisor
NOA No. 15-0513.05
Expiration Date: 03/13/2018
Approval Date: 11/05/2015
E-2
Sun-Tek Manufacturing, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
D. QUALITY ASSURANCE
1. By Miami-Dade County Department of Regulatory and Economic Resources.
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENT
1. Florida Building Code, 2014 Edition, compliance letter prepared by J&L Wells
Consulting LLC, dated 0510512015, signed and sealed by James D. Wells, Jr., P.E.
4. NEW EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No. CMA-002, titled "MD-CMA", sheets 1 and 2 of 2, prepared by Sun-Tek
Manufacturing, Inc., dated May 09, 2011, signed and sealed by James D. Wells, Jr.,
P.E., on October 06, 2017.
B. TESTS
1. None,
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. By Miami-Dade County Department of Regulatory and Economic Resources.
E. MATERIAL CERTIFICATIONS
I. None.
F. STATEMENT
1. Florida Building Code, 2017 Edition, compliance letter prepared by J&L Wells
Consulting LLC, dated 1010612017, signed and sealed by James D. Wells, Jr., P.E.
elmy A.Makar,P.E.,M.S.
Product Control Section Supervisor
NOA No. 15-0513.05
Expiration Date: 03/13/2018
Approval Date: 11/05/2015
E-3
\\`�1S9SJlt��lP/f
18;L Wells Consulting LLC
1453 Arbitus Circle J t
Engineer of Record: > No �3G��
Oviedo,FL 32765 _Z`�:
James D.Wells,Jr.,P.E. - 1 _
Professional No.53616 Engineer (407)496-5439
g Certificate of Authorization No.27162
`���`�` NCO Off' •'���:
PART NAME: M)-C A PLAN SHEET 1 OF 2 /
DRAWN BY; L.B. R D OWG.#z CMA-002
3.000D SV-10.625—I G l p(f 1 S
—l— OufER OONC.Oro POLTGROOH-C
.Om-OLxc.RBO/AIC SHLR
PMAW PAlSU L
_ SNWYC 0[OOING(CONu41105) 'mCmELo WxROl04>
T— S.LLeC aLrN1 903.
A s15-1000 SFAuyt 8[mo
MF1H4D-CMA
l sxtu0N1 MO cove
CO (c4wNnns)
p OO IM MA Su- 10
OO papppcppo PU1 xLtnitnua
O0 MWSBEiOCOR[ARM[RS
to's .JS u—,—440
x)JL04G vx W[R nl[n A10 PeYmenwt
(t)/vtGt[SN[ P.yRlfl PALyS/ON�.
5 9[C rm
f10 x Z P.twas van tfftp 5>ffET lleut 5[R�p
VI ON LONG sm.(S)ON S.aat SNE
LU
Ne
p�N.
DIMENSIONS FOR
X
FASTENER LOCATIONS = na.3,awsscREet rfTN s°o`to*A' kAWE`co ptn
N)BN LO.NO s'x =E Comm) p
14 FASTENERSo (5)ON S-041 S.x
TO CURBIn ru,ac B ar.M�N
N AC[ORBI.{E[�"^� S[NULS(a
2.STP(SC k%)CURB NE"I 10 BE
S.V/yI1CIEHi Ta V-41A.N
6 RIVETS °[fRµt T°T"0 S-A E
SUPPLIED w O'KR w
POLY TO ALUM NOTE:
(4v M t-C count')
RIVET LOCATIONS SYM O (1) ALL ROOFING DETAILS SHALL COMPLY WITH
CHAPTER 15 OF THE 2017 FLORIDA BUILDING CODE
o
(2) 4'MINIM DESIGN PRESSURE RATINGUM DISTANCE FROM ANGLE LIP TO ROOF }— 6D PSF.
1 SURFACE IS FOR SHINGLE. OR B.U.R. WITHOUT
11 INSULATION. FOR INSULATION AND TILE ROOF ADD LARGE MISSILE IMPACT RESISTANCE
_ TILE HEIGHT AND INSULATION THICKNESS TO 4-
MINIMUM HEIGHT.
(3) ANCHORS TO BE MADE OF NON-CORROSIVE MATERIAL.
COMPATABLE WITH ALUMINUM.
27.2�V MAX._ _
l�.:ti)j_111 'i•'t7y::Ji [I„i'1
FASTENER SCHEDULE SKYLIGHT i0 CURB FASTENER SCHEDULE CURB RIVET SCHEDULE DECO
ff 10 K 2 PAN HEAD SHEET METAL SCRE4 S TO DECK (Jl0 K 3- DECK 10 POLYCARSONATE 3/16" DW. Z.-'t''�=t']�%+�e`�+�T?P 1 C F?j) ;
SCREWS
PER LONG PER SHORT PER LONG PER SHORT PER LUNG PER SHORT ,'L':F.'.i;et1;:•.i'tiOI - b 9 y "•3s:.;,gg
MODEL SIDE SIDE SIDE SIDE SIDE SIDE t:X('siS='21Ca73t�_E: O 4-] /g
46 4 3 A 3 2
22 4 3 A 2
r
225030 3 3 3 3 2 1 `-`•� _
?414 3 3 3 3 1 1 >`n1&.ii! 3r
3 a 3 t 1
146 4 3 2 1
14 3 1
1422 3 3 3 3 1 t
m e 2
RCVISION RE VISION! PRODUCT NAME+
N_ _ __ NI -_._ N��-CfV1A Sl;\-TEK N�[A\+UFACTURivG, INC.
OAT_=5.09.11 Sr_ALE� OwG Nd: A-0D2 10303 GENCRAL DRNE ORIANDO. FL 3262A
���tJ1111f Tip//
c�pAV1D YyF(�sdddf
J£a L Wells Consulting LLC �t Q'�; ',,�i ✓n`s
1453 ArbilLIS Circle
Engineer of Record: Ovicdo,FL 32765
James D.Wells,Jr.,P.E. (407)496-5489 `�j 0. 313 - t' =
Professional Engineer No.53616 GertiCcate of Authorization No.27162 =•�i
--0, /0A/?-°/? zz
-
��t: EOF
PART NAME: PRODUCT DRAWINGSHEET 2 OF 2 � , pWG,W:CMA-002
DRAW BY: J F
_ 11I1ld%e
DESIGN PRESSURE RATING
+— 60 PSF
#10 X 2" SCREW PPH LARGE MISSLE IMPACT RESISTANCE OUTER DOME .070 POLYCARBONATE
(4) ON LONG SIDE& (3) ON SHORT SIDE (Polrom Polsun,
MINIMUM ENBEDMENT 1" Sheffield Mokroion or
Sobic Lexan 9034)
_ SILICONE BEDDING (CONTINUOUS) ,
DECO RING STI-275
.060 THICK ALUMINUM -BUTYL RUBBER SEALANT
6063 T6 MITRE BETWEEN SKYLIGHT
AND WELDED CORNERS AND CURB (continuous)
INNER LINER .030 polycorbonot 5-1/2" DOME RISE SHIM* EA, ANCHOR (TYP)
WITH LOAD BEARING SHIM
(Polrom Polsun, AIR RLI ED INSULATED SPACE
Sheffield Mokrolon-or —0.500 MAX.
Sobic Lexon 9034)
;;3 cr`mrly+Ga v;i1n??Io��rf;,az:
FTuil ing G'3L 3/16" RIVET
s )/
NcceRi_;,zce?doh 1-I�Z-3•I (1)/SHORrS50iDE
;�xrson Date z o
Ely
imii Dace r -ac m r:,j #10 x 3" DECK SCREW
4" MINIMUM FINISHED WALL MATERIAL (4) ON LONG SIDE I FLASHING BY OTHERS IN
SEE NOTE #2 BY OTHERS ( APPROVED (3) ON SHORT SIDE 1 ACCORDANCE WITH NRCA
DADE COUNTY) MINIMUM ENBEDMENT 5/8"
TINGLES
(2) �co
0
NOTE:
(1).ALL ROOFING DETAILS SHALL COMPLY WITH n'
• CHAPTER 15 OF THE 2017 FLORIDA BUILDING CODE
(2) 4" MINIMUM DISTANCE FROM ANGLE LIP TO ROOF
SURFACE IS FOR SHINGLE. OR B.U.R, WITHOUT
2X SYP (SG 0.55) CURB HEIGHT INSULATION. FOR INSULATION AND TILE ROOF ADD
TO BE SUFFICIENT TO MAINTAIN TILE HEIGHT AND INSULATION THICKNESS TO 4"
4• MINIMUM AT LOWEST POINT MINIMUM HEIGHT.
OF FRAME TO ROOF SURFACE (3) ANCHORS TO BE MADE OF NON-CORROSIVE MATERIAL, ROOF DECK
SUPPLIED BY OTHERS AN COMPATABLE WITH ALUMINUM.
(APPROVED BY DADE COUNTY)
STS-1000 SEALANT (CONTINOUS)
REVISION REVfSlON: PRODUCT NawC
IU1D-CMA SUN-TEK MAINUFACTURING. INC.
1Ni• Ill: 10303 GENERAL DRNE ORWIDO, FL 3282c
OATEN i t SCALE: D , A-