Owens Corning Roofing and Asphalt,LLC Evaluation Report 111980.11.08-R11
One Owens Corning Parkway PL11602-R10
Toledo,OH 43659 Date of Issuance: 11/03/2008
(740)321-6345 Revision 11: 10/17/2019
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E.for,use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 10 Edition(2017) Florida Building Code sections noted
herein.
DESCRIPTION: Titanium'" Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein,
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E.of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of
this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official,
This Evaluation Report consists of pages 1 through 8.
Prepared by:
r
•,': :isNo�57t;�•
Robert J.M. Nieminen PE �' � r :
r . . �%i;�' : � The facsimile seal appearing was authorized by Robert
Florida Registration No.59166,Florida DCA ANE1983
iO'�a��' Nleminen,P.E.on 10/17/2019.This does not serve as an
.:-r��.,r,;,;,�1��� .
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have,nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2, NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4, Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
02018 NEMO ETC,LLC
r ,
• r
ONEMOletc.
ROOFING COMPONENT EVALUATION:
e• Wil
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Titanium''Roof Underlayments,as produced by Owens Corning Roofing and Asphalt,LLC,
have demonstrated compliance with the intent of the following sections of the 6t' Edition (2017) Florida Building
Code through testing in accordance with applicable sections the following Standards. Compliance is subject to the
Installation Requirements and Limitations/Conditions of Use set forth herein.
_ t
1• D
Section Property Standard Year
1504.3.1 Wind Uplift UL 1897 2012
1S07.1.1,R905:1.1 Exception Unrolling,Breaking Strength,Pliability ASTM D226 2009
1507.1.1,R90S,1.1 Exception Tear Strength ASTM D1970 2015
1507.1.1,T1507.1.1,1507.2.9.1 Physical Properties ASTM D1970 2015
1507.3.3 Physical Properties FRSA/TRI April 2012(04-12) 2012
TAS 110 Accelerated Weathering ASTM D4798 2011
TAS 110 Pull-through resistance TAS 117(B) 1995
Entity Examination Reference Date
ERD(TST6049) Physical Properties 115010.04.09 04/29/2009
ERD(TST6049), Physical Properties 115010.05.10 05/14/2010
ERD(TST6049) Physical Properties 135520.06.11 06/15/2011
ERD(TST6049) ASTM D226 138010.08.11 08/11/2011
ERD(TST6049) Wind Uplift 135520.08.11-1 08/12/2011
ITS(TST1509) ASTM D226 311801000Q-003 04/26/2007
ITS(TST1509) ASTM D226 3130639COQ-002A 08/21/2007
ITS(TST150% Physical Properties 3126617COQ-005 10/31/2007
ITS(TST1509) ASTM D226 101823107COQ-011 01/23/2015
ERD(TST6049) Physical Properties(NH) 4j-OC-19-SSUDL-01.A 06/14/2019
Owens Corning Product equivalency Declaration 06/18/2018
PRI(TST5878) ASTM D1970 OCF-341-02-01 09/20/2017
PRI(TSTS878) ASTM D1970;Tear strength OCF-331-02-02 10/03/2017
PRI(TST5878) ASTM D1970;Tear strength OCF-332-02-02 10/03/2017
PRI(TST5B78) ASTM D1970;Tear strength OCF-334-02-02 10/03/2017
PRI(TST5878) FRSA/TRI April 2012(04-12),partial OCF-343-02-01 11/09/2017
PRI(TST5878) ASTM D4798 OCF-341-02-01 11/27/2017
PRI(TST5878) TAS 117(B);Pull-through OCF-422-02-02 04/03/2018
PRI(TST5878) FRSA/TRI April 2012(04-12),partial OCF-425-02-01 08/13/2018
PRI(TST5878) ASTM D226/ASTM D4798 OCF-331-02-01 R1 05/07/2019
PRI(TST5878) ASTM D226/ASTM D4798 OCF-332-02-01 RI 05/07/2019
PRI(TST5878) ASTM D226/ASTM D4798 OCF-334-02-01 R1 05/07/2019
PRI(TST5878) UL1897 1378TO02 07/10/2019
PRI(TST5878) Tensile adhesion OCF-507-02-01 08/13/2019
ITS(QUA1673) Quality Control ITS Listings Current
ITS(QUA1673) Quality Control Service Confirmation 09/30/2017
MEMO ETC,LLC Evaluation Report 111980.11.08-RS1
Certificate of Authorization#32455 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL11602-R10
Titanium Roof Underlayments Revision 11:10/17/2019
Page 2 of 8
NNEM01 etc.
11 Will
Product Specification Plants Description
4.1 TitaniumT1 PSU-30 ASTM D1970 Dubai,UAE& unreinforced polymer modified bitumen material adhered
and FRSA/TRI Brentwood, NH to the underside of a polymer-coated,synthetic woven
April 2012 sheet. The underside is backed with a release film. Unit
weight 24 Ibs/square
4.2 Titanium'" UDL-25 FBC 1507.1.1 Qingdao,China synthetic sheet-type underlayment comprised of a woven
&R905.1.1 core coated on one side with a polymer coating. Unit
(Exception) weight 2.5 Ibs./square
4.3 Titanium'" UDL-30 FBC 1507.1.1 Mission, BC, synthetic sheet-type underlayment comprised of a woven
&R905.1.1 Canada& core coated on both sides with a polymer coating. Unit
(Exception) Qingdao, China weight 4.0 Ibs./square
4.4 TitaniumTM UDL-50 FBC 1507.1.1 Mission, BC, synthetic sheet-type underlayment comprised of a woven
&R905.1.1 Canada& core coated on both sides with a polymer coating. Unit
(Exception) Qingdao,China weight 4.7 Ibs./square
•
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of
this product.
5.4 Titanium'" Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed,a request may be made to the Authority Having Jurisdiction
for approval based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Asphalt Wood Shakes
Underlayment Shingles Nail-On Tile Foam-On Tile Metal &Shingles Slate
Titanium PSU-30 Yes Yes Yes Yes Yes Yes
(See 5.5.1)
Titanium UDL-25 Yes No No Yes Yes Yes
Yes Yes
Titanium UDL-30 Yes (Base Sheet in 2-ply (Base Sheet In 2-ply Yes Yes Yes
system) system)
Titanium UDL-50 Yes No No Yes Yes Yes
NEMO ETC,LLC Evaluation Report 111980.11.08-R11
Certificate of Authorization#32455 6Tu EDITION(2017)FBC NON-HVHZ EVALUATION FL11602-R10
Titanium Roof Underlayments Revision 11:10/17/2019
Page 3 of 8
ONEMOletc.
5.5.1 "Foam-On Tile" is limited to use of following Approved tile adhesives/underlayment combinations.
TABLE 1A:ALLOWABLE TILE ADHESIVE/UNDERLAYMENT COMBINATIONS'
Underlayment Adhesive Florida Product Approval
DUPONT Tile Bond'" FL22525
Titanium PSU-30 ICP Adhesives Polyset®AH-160 FL6332
ICP Adhesives Polyset®RTA-1 FL6276
5.6 Allowable Substrates(for self-adhering):
TABLE 2: SUBSTRATE OPTIONS
Underlayment Primer Substrates
(Optional)ASTM D41 plywood
None ASTM D226 felt
Titanium PSU-30
ASTM D41 Titanium UDL-30
None Titanium UDL-30(inverted)
5.6.1 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where the underlayment
forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile applications. Maximum Design Pressure is
the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2(the 2 to 1 margin of safety per FBC 1504,9 has already been applied).Refer to FRSA/TRI April
2012(04-12),Appendix A,Table 1A or FBC 1609 for determination of design wind loads.
#1 Maximum Design Pressure=-45 psf:
Deck: Min, 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: (Optional)ASTM D41
Underlayment: One or two plies, Titanium PSU-30, self-adhered and back-nailed max. 6" o.c. with 12 ga.
galvanized annular rink shank nails through 32 ga.,1-5/8-inch diameter tin caps in accordance with
Owens Corning Roofing and Asphalt, LLC published installation requirements,
#2 Maximum Design Pressure=-30 psf*:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Titanium UDL-30(inverted)
Fasteners: 12 ga.annular ring shank nails having not less than 20 rings per inch,heads not less than 3/8 inch
diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch
with min.32 ga,, 1-5/8"diameter tin caps
Spacing: 6-inch o.c.at 4-inch wide side laps and 12-inch o.c. at three(3),equally spaced center rows.
Primer: ASTM D41 primer required at all tin-caps.
Underlayment: One or two plies,Titanium PSU 30,self-adhered and back-nailed max,6"o.c,with 12 ga,galvanized
annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens
Corning Roofing and Asphalt, LLC published installation requirements.
z Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC,LLC Evaluation Report 111980.11.08-Rll
Certificate of Authorization#32455 6r"EDITION(2017)FBC NON-HVHZ EVALUATION FL11602-R10
Titanium Roof Underlayments Revision 11:10/17/2019
Page 4 of 8
MEMO I etc.
#3 Maximum Design Pressure=-30 psf*:
Deck: Min, 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Titanium UDL-30(printed side up)
Fasteners: 12 ga.annular ring shank nails having not less than 20 rings per inch,heads not less than 3/8 inch
diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch
with min.32 ga., 1-5/8"diameter tin caps.
Spacing: 6-inch o.c.at 4-inch wide side laps and 12-inch o.c.at three(3),equally spaced center rows.
Primer: ASTM D41 primer required over printed side of UDL-30.
Underlayment: One ortwo plies,Titanium PSU 30,self-adhered and back-nailed max.6"o.c.with 12 ga.galvanized
annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens
Corning Roofing and Asphalt,LLC published installation requirements.
#4 Maximum Design Pressure=-45 psf*:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Titanium UDL-30(inverted)
Fasteners: 12 ga.annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch
diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch
with min.32 ga., 1-5/8"diameter tin caps
Spacing: 6-inch o.c.at 4-inch wide side laps and 8-inch o.c,at three(3),equally spaced center rows,
Primer: ASTM D41 primer required at all tin-caps.
Underlayment: One or two plies, Titanium PSU 30, self-adhered and back-nailed 6" o.c. with 12 ga. galvanized
annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens
Corning Roofing and Asphalt, LLC published installation requirements.
#5 Maximum Design Pressure=-45 psf*:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Titanium UDL-30(printed side up)
Fasteners: 12 ga.annular ring shank nails having not less than 20 rings per inch,heads not less than 3/8 inch
diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch
with min.32 ga., 1-5/8"diameter tin caps.
Spacing: 6-inch o.c.at 4-inch wide side laps and 8-inch o.c,at three(3),equally spaced center rows.
Primer: ASTM D41 primer required over printed side of UDL-30.
Underlayment: One or two plies, Titanium PSU 30, self-adhered and back-nailed 6" o.c. with 12 ga. galvanized
annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens
Corning Roofing and Asphalt, LLC published installation requirements.
5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or
exceed that required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC 1609. Zones 2 and 3 shall employ an attachment density designed by
a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI
WD1,FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an
asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016)
for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Titanium UDL-25,Titanium UDL-30,Titanium UDL-50 or Titanium PSU-30 shall not be left exposed for longer than
180-days.
NEMO ETC,LLC Evaluation Report 111980,11.08-R11
Certificate oJAuthorization N32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL11602-R10
Titanium Roof Underlayments Revision 11:10/17/2019
Page 5 of 8
ONEMOletc.
5.8 Tile Slippage Limitations(per FRSA/TRI April 2012(04-12)1:
When loading roof tiles on the underlayment in direct-deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
TABLE 3:'TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS
Underlayment Tile.Profile Staging Method Maximum Slope
Flat Max. 10-tile stack 5:12
Flat Max 5-tile stack 6:12
Lugged Max. 10-tile stack 4:12
Lugged Max.5-tile stack 5:12
Max. 10-tile stack(5 over 5)
Titanium PSU-30
Lugged 5:12
�M.
6.1 Titanium Roof Underlayments shall be installed in accordance with Owens Corning Roofing and Asphalt, LLC
published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted
below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application,and prime the substrate(if applicable).
6.3 TitaniumTM UD1145,7itanium UbL=30:or Titanium UDL-50:
6.3.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or 11 underlayment in FBC Table
1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed,considering the wider sheet-width.
6.3.2 Fasteners:
Mechanical attachment of Titanium UDL-25 and Titanium UDL-30 is limited to ring shank roofing nails with
minimum 1-inch diameter plastic caps.
Mechanical attachment of Titanium UDL-50 is limited to ring shank roofing nails with minimum 3/8-inch diameter
heads;ring shank roofing nails with minimum 1-inch diameter plastic caps;screws and plates;or plastic cap staples.
6.3.2.1 Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 states: "...except metal cap nails shall
be required where the ultimate design wind speed, Va,,it,equals or exceeds 150 mph."
Owens Corning Roofing and Asphalt, LLC has furnished data to permit the use of 1-inch diameter plastic cap nails
in lieu of metal cap nails for these applications,when the TitaniumTm UDL-25,Titanium UDL-30 or Titanium UDL-50
underlayment is installed beneath mechanically fastened prepared roof covers referenced in FBC Table 1507.1,1
or R905.1.1.
NEMO ETC,LLC Evaluation Report 111980.11.08-RS1
Certificate of Authorization N32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL11602-R10
Titanium Roof Underlayments Revision 11:10/17/2019
Page 6 of 8
ONEMOjetc.
6.3.3 Slopes of 4:12 or greater:
End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 4-inches. End (vertical)
laps shall be offset from course to course not less than 6 feet.
Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. When batten systems are to be
installed atop the underlayment,the underlayment need only be preliminarily attached pending attachment of the
battens.
6.3.4 Slopes of 2:12 to less than 4:12:
End(vertical)laps shall be minimum 12-inches and side(horizontal)laps shall be minimum 25-inches. End(vertical)
laps shall be offset from course to course not less than 6 feet,
Begin by fastening a 25-inch wide strip along the eaves. Place a full-width sheet over the starter, completely
overlapping the starter course. Continue upslope,maintaining minimum 25-inch side(horizontal)laps,resulting in
a double-layer application.
Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. Secure end laps 4-inch o.c.
When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily
attached pending attachment of the battens.
6.4 Titanium'";PSU-30:
6.4.1 Non-Tile Installations:
Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed, and Owens Corning published requirements.
Titanium'" PSU-30 shall be back-nailed in accordance with Owens Corning published installation requirements.
6.4.2 Nail-On Tile Applications:
Shall be installed in compliance with the requirements for Self-Adhered Membrane underlayment set forth in
FRSA/TRI April 2012 (04-12),and Owens Corning published requirements, Titanium'"' PSU-30 shall be back-nailed
max. 6" o,c. with 12 ga. galvanized annular rink shank nails through 32 ga„ 1-5/8-inch diameter tin caps in
accordance with Owens Corning published installation requirements.
Refer to Section 5,8 for tile staging limitations.
6.4.3 Foam-On Tile Applications:
Shall be installed in compliance with the requirements for Self-Adhered Membrane underlayment set forth in
FRSA/TRI April 2012 (04-12),and Owens Corning published requirements.Titanium'"' PSU-30 shall be back-nailed
max, 6" o.c. with 12 ga, galvanized annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in
accordance with Owens Corning published installation requirements.
Refer to Table 1A for allowable tile adhesives.
Refer to Section 5.6,1 for wind uplift limitations.
Refer to Section 5.8 for tile staging limitations.
6.5 Titanium 2=Ply-System::
6.5.1 The Titanium 2-Ply System consists of a base layer of Titanium UDL-30 (top-surface primed or sheet inverted)
mechanically attached to the wood roof deck followed by Titanium PSU-30,self-adhered.
6.5.2 Non-Tile Applications:
Install Titanium UDL-30(top surface primed or sheet inverted)in accordance with Section 6.3 followed by Titanium
PSU-30 in accordance with Section 6.4.
NEMO ETC,LLC Evaluation Report 111980.11,08-R11
certificate of Authorization#32455 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL11602-R10
Titanium Roof Underlayments Revision 11:10/17/2019
Page 7 of 8
ONEMOjetc.
6.5.3 Nail-On Tile Applications:
For nail-on tile installations, install Titanium UDL-30 (top surface primed or sheet inverted) in accordance with
FRSA/TRI April 2012(04-12),using Section 6.3 as a guide,and considering the wider sheet width relative to ASTM
D226 felt. Then apply Titanium PSU-30 in accordance with Section 6.4.
Refer to Section 5.8 for tile staging limitations.
6.5.4 Foam-On Tile Applications:
For foam-on tile installations, install Titanium UDL-30 (top surface primed or sheet inverted) in accordance with
Section 5.6.1 herein. Then apply Titanium PSU-30 in accordance with Section 6.4
Refer to Table 1A for allowable tile adhesives.
Refer to Section 5.6.1 for wind uplift limitations.
Refer to Section 5.8 for tile staging limitations.
D D Me-q
�, - As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
Sam M_
Contact the manufacturer or the named QAentity for plants covered under Rule 61G20-3 QA requirements. Refer
to Section 4 herein for product&production locations having met codified physical properties specifications.
® 1
W;ar M mum
Intertek Testing Services NA Inc,—QUA1673; (604)520-3321
-END OF EVALUATION REPORT-