HomeMy WebLinkAboutProduct Approval (2) 214j2in ) Florida Building Code Online
u
j 1ti » ei6 Y� o f i
9
.,Jm
s y��5
-. ._
k.�•q�n�5 e a�S�ti����*` !�"P�; ���.fil�7.�a��,`y§rt`.�„3 � ,�X���st .aux "m.�..1
BQS Home { Log In { User Re9fstration { Hot Tapi6 ; Submit Surcharge i Stats&Facts j Publications { Contact Us I BCIS Site Map I links } Search ;
Florida
f Product Approval
r ( ; ¢ USER:Public User "RECEIVED
Product Aoyroval t4enu>Product or Aoplication Search>Agptication List>Application Detail
�le ; —. MAR 1 6 2020
r fit ar§s3 # FL17022-R7
Application Type Revision ST. Lucie County, Permitting
Code Version 2017
Application Status Approved
Comments 08/18/2017v.date reapply 08/21/17
Archived
Product Manufacturer Extreme Metal Fabricators,LL REV � {�® ��
p�
Address/Phone/Email 2160 SW Poma rive CjODE COMPLIANCE
Palm City,FL 34990
(772)872-8034 ST. L.UCIE COUNTY
fivalidation@yahoo.com �a
BOCC
Authorized Signature Richard McKuhen
fivalidation@yahc)o.com
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive
Palm City, 34990 File Copy
(772)872-8034
rchard@emfab.net
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the LOCKE BOWDEN
Evaluation Report
Florida License PE-49704
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Zachary R.Priest,P.E.
' Validation Checklist-Hardcopy Received
Certificate of Independence FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.pdf
Referenced Standard and Year(of Standard) Standard Year
TAS 125 2003
UL1897 2012
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
https:/Iwwwfloridabuilding.org/pr/pr app dU.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d 1/3
214120-',g Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted 08/18/2017
Date Validated 08/25/2017
Date Pending FBC Approval 08/28/2017
Date Approved 10/10/2017
Summary of Products
FL# ,NumMer or Name Description
17022.1 1-"5V Crimp"(116) 26 Gauge.steel,3/8"db-height,24"_widelapped.roof panel
mechanically attached to 15/32"plywood or Wood Deck with
fasteners
Limits of Use Insta ation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 17022.1 5 V CRIMP ssr.pdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/Table A Evaluation Reports
Other: Refer to evaluation report for conditions.Install the FL17022 R7 AE FL 17022.1 5 V CRIMP ssr pdf
assembly in compliance with the installation method listed in Created by Independent Third Party:Yes
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
17022.2 2-"5V Crimp"(R6) 0.032"Aluminum,3/8"Rib height,21"wide lapped roof panel,
mechanically attached to 15/32"plywood or Wood Deck with
exposed fasteners
Limits of Use Installation Instructions
Approved for use in HVHZ: No PL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssr pdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure:+N/A/Table A Evaluation Reports
Other:Refer to evaluation report for conditions.Install the FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 ALUM ssr pdf
assembly in compliance with the installation method listed in Created by Independent Third Party:Yes
this report and applicable code sections of FBC.Refer to
manufacturers installation instructions.
17022.3 3-"1.5"Mechanical Seam"(115) 1.5"rib height,16"wide,24 gauge steel,standing seam roof
panel mechanically attached to 15/32"plywood or wood deck
with clips and fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 17022.3 1.5 MECHANICAL
Approved for use outside HVHZ: Yes seam 24aa ssr.pdf
Impact Resistant: No Verified By: Locke Bowden,P.E.49704
Design Pressure:+N/A/Table A Created by Independent Third Party:Yes
Other:Refer to evaluation report for conditions and limitations Evaluation Reports
of use.Install the assembly in compliance with the installation FL17022 R7 AE FL 17022.3 1.5 MECHANICAL
method listed in this report and applicable code sections of seam 24aa ssr.pdf
FBC. Refer to manufacturer's installation instructions. Created by Independent Third Party:Yes
17022.4 4-"1.5"Mechanical Seam"(115) 1.5"rib height, 16"wide,0.032"aluminum,standing seam roof
panel mechanically attached to 15/32"plywood or Wood Deck
with clips and fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 17022.4 MECHANCIAL SEAM
Approved for use outside HVHZ:Yes ALUMINUM ssr.odf
Impact Resistant: No Verified By: Locke Bowden,P.E.49704
Design Pressure:+N/A/Table A Created by Independent Third Party:Yes
Other: Refer to evaluation report for conditions and limitations Evaluation Reports
of use.Install the assembly in compliance with the installation FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM
method listed in this report and applicable code sections of ALUMINUM ssr.pdf
FBC.Refer to manufacturer's installation instructions. Created by Independent Third Party:Yes
17022.5 5-"1 in. Nail Strip"(115) 1"rib height, 16"wide,26 gauge steel,standing seam roof
panel mechanically attached to 15/32"plywood or wood deck
with fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssr.pdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure:+N/A/Table A Evaluation Reports
Other: Refer to evaluation report for conditions and limitations FL17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssr.pdf
of use.Install the assembly in compliance with the installation Created by Independent Third Party:Yes
https://www.floridabuilding.org/pr/pr app dti.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d 213
2/4/2019 Florida Building Code Online
method listed in this report and applicable code sections of
FBC.Refer to manufacturer's installation instructions.
17022.6 6-71 in.Nail Strip"(115) 1"rib height, 16"wide,0.032"aluminum,standing seam roof
panel mechanically attached to attached to 15/32"plywood or
Wood Deck with fasteners,
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 17022.6 1.0 NAIL STRIP 0.032 l
Approved for use outside HVHZ:Yes ALUM ssrpdf
Impact Resistant:No Verified By: Locke Bowden,P.E.49704
Design Pressure:+N/A/Table A Created by Independent Third Party:Yes
Other: Refer to evaluation report for conditions and limitations Evaluation Reports
of use.Install the assembly in compliance with the installation FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0,032
method listed in this report and applicable code sections of ALUM ssrpdf
FBC.Refer to manufacturer's installation instructions. Created by Independent Third Party:Yes
17022.7 7-"1.5 in. Nail Strip"(115) 1.5"rib height, 19"wide,26 gauge steel,standing seam roof
panel mechanically attached to 15/32"plywood or wood deck
with fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 17022.7 1.5 Nail Strip 26GA ssrpdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other: Refer to evaluation report for conditions and limitations FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr pdf
of use.Install the assembly in compliance with the installation Created by Independent Third Party:Yes
method listed in this report and applicable code sections of
FBC.Refer to manufacturer's installation instructions.
17022.8 8-"EMAX Rib"(115) 29 gauge steel,lapped roof panel mechanically attached to
15/32"plywood or wood deck with exposed fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 177022.8 EMAX Rib ssrpdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/Table A Evaluation Reports
Other: Refer to evaluation report for conditions and limitations FL17022 R7 AE FL 177022.8 EMAX Rib ssr pdf
of use.Install the assembly in compliance with the installation Created by Independent Third Party:Yes
method listed in this report and applicable code sections of
FBC.Refer to manufacturer's installation instructions.
17022.9 9-"PBR MAX"(R5) 26 gauge steel,lapped roof panel mechanically attached to
15/32"plywood or wood deck with exposed fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 17022.9 PBR RIB ssrpdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure:+N/A/Table A Evaluation Reports
Other:Refer to evaluation report for conditions and limitations FL17022 R7 AE FL 17022.9 PBR RIB ssrpdf
of use.Install the assembly in compliance with the installation Created by Independent Third Party:Yes
method listed in this report and applicable code sections of
FBC.Refer to manufacturer's installation instructions.
wac� i�snr'
Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copvrioht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395. `Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please dick ewe-.
Product Approval Accepts:
Credit_Card
Safe
https:/Avww.flaridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkcHzEgvOQveeg%3d%3d 3/3
e G S 0
c e
2160 SW Poma Drive
Palm City, FL 34990
772)872-8034
A
Compliant with Florida Building Code 2017 (61h ed.)
Compliant with Florida Product Approval Rule#61G20-3
Compliant: Keystone Certifications
Product:-S-V-Crimp"26GA-Steel Roof Panel FBC'Sec. 1507:4.2
Yield strength:50 ksi'min.;.Attachedito-min: 15/32"-plywood-or Wood
Deck-w/min.,0.42-specific-gravity with screws. 24"-Coverage
Rib 1 "
Corrosion Resistant Compliant: FBC Sec. 1507.4.3
Fastener 1 (Method 1 Attachment):#9 x 1-1/2" Hex-Washer Head wood screw* to penetrate
3/16" min. thru deck or 5/8"embedment into wood plank. (*or sufficient length to meet
requirements)
Fastener.2 (Method 2,3, 8t 4 Attachment):#10 x 1-1/2" Hex-Washer Head wood screw* to
penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length
to meet requirements)
Underlayment: To be compliant with FBC Sec. Chart 1507.1.1
Slope: Shall be in compliance with FBC Sec. 1S07.
See Fastener attachment specifications above
Install Details: Table A Allowable Loads METHOD 1 METHOD 2 METHOD 3 METHOD 4
DESIGN PRESSURE* -86 PSF -93.5 PSF -101 PSF -228 PSF
ROW SPACING 16"o.c. 16"o.c. 8"O.C. 6"o.c.
FASTENER SPACING (ALONG-Panel width) 12" o.c. 12"ox. 12"ox. 12"ox.
FASTENER SIZE 1 #9 #10 #10 #10
Reference Data: ARCHITECTURAL TESTING,INC.TST ID#:1527
UL 580-06& 1897-041 Test Report IM893.01-450-18 05/02/14
Test Report F3366.01-450-18 12/18/15
TAS 125-03 Test Report D05893.02-450-18 07/22/14
*EQUIVALENCY-UL 1897-04 is equivalent to test standard UL 1897�-1 fj *Design pressure margin of safety 2.1
Locke Bowden,P.E.does not have,not will acquire a financial ini'�te`a q ee cq rD�lm Wacturing or distributing products
under this evaluation. a tl
Locke Bowden,P.E.is not owned,operated,or controlled by air cot tpand00.0 biltt1�turep,or distributing products under this
report. ti ; °
_ r
4 1 pp.�pppp
'� :fl::: ll11N•
I
FL17022.1 5V Crimp (26GA Steel), 24"Wide Roof Panel -Details
Limitations:.
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6t'ed.
2. Minimum slope to be compliant with Florida Building Code 2017 6"h ed., and per with Manufacturer's installation reference.
3. Products are compliant-for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D
4. Engineering analysis for"project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance.Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6t'ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for
Structural Loading.
7.This report does not imply warranty, installation, recommended product use outside of this report.
Fasteners-
/_t_91
x 1-1121 in.or
0 x 1-1/Y Min.per Table A'for Row 5•V Crimp Roof Panel
Spacing and Design Pressures
Hex Washer Head Wood Screws
f~
Dedc
-15/32'or greater Plywood,or
-Wood plank
247
1r
3/8"
nn n �n
OPTIONAL.STRIATIONS
Panel Profile
Nominal 12" Nominal 12"
O.C. O.C.
Fasten
LVJ�=1/2"Min. or #10 x 1-1/2"Min.per
Table"A" Hex Washer Head Screw
Spaced 12"o.c.across the Panel Wdth
Panel Refer to Table"A"for Spacing Along Panel
Overlap Length
Deck-15/32"or greater
Plywood,or
-Wood plank