HomeMy WebLinkAboutProduct Approval M1 �R 11
Business & Professional Regulation
BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats&Facts I Publications I Contact Us I BCIS Site Map I Links I Search
d
dlodda
rS `,Product Approval
a USER:Public User
aF�uum
Product Approval Menu>Product or Application Search>PpDlintion List>Application Detail
Nit FL# FL2847-R12
Application Type Revision
Code Version 2017
Application Status Approved
k *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
I
Comments
Arch ived O
Product Manufacturer Lomanco,Inc
j Address/Phone/Email 2101 West Main Street
Jacksonville,AR 72076
(501)982-6511
kjelley@lomanco.com
i Authorized Signature Katrina Jelley
kjelley@lomanco.com
I '
Technical Representative Dennis Mathes
Address/Phone/Email Lomanco Inc.
2101 West Main Street
Jacksonville,AR 72076
(501)982-6511 Ext359
dmathes@lomanco.com
i
Quality Assurance Representative Dennis Mathes
Address/Phone/Email 2101 West Main Street
Jacksonville,AR 72076
(501)982-6511 Ext359
dmathes@lomanco.com
i
Category Roofing
Subcategory Roofing Accessories that are an Integral Part of the Roofing System
i
Compliance Method Evaluation Report from a Product Evaluation Entity
Evaluation Entity Miami-Dade BCCO-EVL
Quality Assurance Entity Miami-Dade BCCO-QUA
jQuality Assurance Contract Expiration Date 08/16/2021
Validated By Miami-Dade BCCO-VAL
I
Certificate of Independence
Referenced Standard and Year(of Standard) Standard Year
Miami-Dade TAS 100(A) 1995
I
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option C
Date Submitted 06/29/2019
Date Validated 07/26/2019
Date Pending FBC Approval
Date Approved 08/02/2019
Summary of Products
i
FL# Model,Number or Name Description
2847.1 Lomanco Lo-OmniRidge LOR9-4; Gun Nailable 4' Ridge Vent for 9"Cap Shingles
TRI-BUILT Lo-OmniRidge LOR9-4
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL2847 R12 II 19050802 Lomanco LOR9-4 NOA.12d
Approved for use outside HVHZ:Yes Verified By: Miami-Dade BCCO-EVL
Impact Resistant: N/A Created by Independent Third Party:
Design Pressure:N/A Evaluation Reports
Other: 1.Refer to applicable building codes for required FL2847 R12 AE 19050802 Lomanco LOR9-4 NOA.pdf
ventilation.2.Ridge Vent shall not be installed on roof hips.3.
Ridge Vent shall not be connected at ridge intersection,nor
within'12"of any side wall or roof protrusion,with a ventilation
slot clearance of 12"from such obstructions.4. Ridge Vent shall
not be installed on roof mean heights greater than 33 feet.
j 284 47 Lomanco Lo-OmniRoll LOR-30;TRI- '60"Gun Nailable Shingle Over Ridge Vent(Sold as 30'roll-six
;BUILT Lo-OmniRoll LOR-30� C60"vents are welded together.),
i
Limits of Use Installation Instructions,
(Approved for use in HV—� HZ:Ye PFL2847 R12 II 18110702 LOR-30 NOA�p_dfl
(Approved for use outside HVHZ:Yes {Verified By: Miami-Dade,B000-EVL
Impact Resistant:N/AI (Created by Independent Third Party
Design Pressure:N/W (Evaluation Reports)
Other: 1. Refer to applicable building codes for requiredL (FL2847 R12 AE 18110702 LOR-30 NOA.pdfi
ventilation.2.OmniRidge Vent shall not be installed on roof,
1mean heights greater than 33 feet. _
2847.3 OmniRidge OR-4 4'Shingle Over Ridge Vent
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL2847 R12 II Lomanco OR-4-NOA 16051027.pf
Approved for use outside HVHZ:Yes Verified By: Miami-Dade BCCO-EVL
I Impact Resistant:N/A Created by Independent Third Party:
Design Pressure: N/A Evaluation Reports
Other: 1.Refer to applicable building codes for required FL2847 R12 AE Lomanco OR-4-NOA 16051027,E
ventilation.2.OmniRidge Vent shall not be installed on roof
( mean heights greater than 33 feet.
I
Back Pdext
I
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy atatement::Accessibility.Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(1),
i Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
® 2.
Credit Card
j Safe
MIAMI-DADE COUNTY
MIAMNDADE PRODUCT CONTROL SECTION
11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Lomanco,Inc.
2101 West Main Street
Jacksonville,AR 72076
( SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
I
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(In Miami Dade County) and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this
product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
{ if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
iThis product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
f DESCRIPTION: Lomanco Lo-OmniRoll LOR-30 Ridge Vent
TRI-BUILT®Lo-OmniRoll LOR-30 Ridge Vent
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
i
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
i
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida,and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
I INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 18-0615.04 consists of pages 1 through 5.
The submitted documentation was reviewed by Freddy Semind,
MIAMFDADE COUNTY NOA No.: 18-1107.02
� Expiration Date: 09/04/23
Approval Date: 01/03/19
Page 1 of 5
i
.ROOFING,COMPONENT APPROVAL
Category: Roofing
;Sub-Category: Ventilation
!Materials: Plastic
{Minimum Slope: 3:12
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT
Test Product
Product Dimensions Specification Description
l
Lomanco Lo-OmniRoll" 60"x 14'/2"x s/8" TAS 100(A) Ridge ventilation system
(LOR-30)Ridge Vent 0.625"thick
TRI-BUILT®Lo-OmniRoll 60"x 14 '/2"x s/8" TAS 100(A) Ridge ventilation system
(LOR-30)Ridge Vent 0.625"thick
f
TRADE NAMES OF PRODUCTS MANUFACTURED BY OTHERS
Test Product
Product Dimensions Specification Description Manufacturer
Roofing Nails Min. 12 ga., TAS 114 Appendix E Corrosion resistant smooth shank Generic
1 3/4" nails
I I
MANUFACTURING LOCATION
1. Jacksonville,AR
EVIDENCE SUBMITTED
Test Agency/Identifier Name Report Date
�PRI Construction Materials Technologies,LLC TAS 100 LOM-003-02-01 01/15/03
TAS 100(A)-95 LOM-028-02-01 08/28/13
ASTM D635 LOM-030-02-01 07/23/13
ASTM D638 LOM-025-02-01 05/30/13
ASTM D1929 LOM-031-02-01 07/23/13
ASTM G155 LOM-025-02-01 05/30/13
NOA No.: 18-1107.02
MIAMMADE COUNTY Expiration Date: 09/04/23
Approval Date: 01/03/19
Page 2 of 5
APPROVED APPLICATIONS
Tradename: Lomanco Lo-Omni Roll(LOR-30)Ridge Vent
TRI-BUILT®Lo-OmniRoll(LOR-30)Ridge Vent
System Type: Mechanical attachment of ridge vent system over composition shingles.
I
Slot: Truss Construction: Cut shall be 1-1/4"wide and 6" shorter at each end than the total
I length of the ridge vent to be installed.
i
Ridge Pole Construction: Cut shall be 2 3/4"" wide and 6" shorter at each end than the
total length of the ridge vent to be installed.
i
Installation: Mark proper alignment and end line for vents with chalk; snap a chalk line down both
sides of the ridge at a distance of 7"down from the peak as shown in the
manufacturer's installation instructions.
i
Center the length of vent along the ridge. Start nailing with minimum 1 3/4"roofing
nails placed 6"on center at manufacturer pre-marked locations. Use nails of sufficient
length to penetrate through the sheathing a minimum Of 3/16"or at least 1"into wood
plank decking thicker than 1". Cut lines are provided if more than one vent is being
used(See manufacturer installation manual). Additional pieces shall run in the same
direction as they unroll out of the carton.
Ridge Shingle: Using nail lines provided on top of vent, install the cap shingles directly to the vent,in
compliance with the shingle manufacturer's Notice of Acceptance(NOA)and
installation instructions,using roofing nails of sufficient length to penetrate through the
sheathing a minimum of 3/16"or at least 1"into wood plank decking thicker than 1".
Ventilation Calculations: Refer to manufacturer's published literature.
i
I
i
NOA No.: 18-1107.02
MIAMMADE COUNTY Expiration Date: 09/04/23
1 Approval Date: 01/03/19
Page 3 of 5
LIMITATIONS
1. Refer to applicable Building Code for required ventilation.
2. Ridge Vents shall comply with applicable Building Code.
j 3. Lomanco Lo-Omni Roll(LOR-30)Ridge Vent and TRI-BUILT®Lo-OmniRoll(LOR-30)Ridge Vent
shall not be installed in conjunction with Gable vents.
4. Lomanco Lo-Omni Roll(LOR-30)Ridge Vent and TRI-BUILT®Lo-OmniRoll(LOR-30)Ridge Vent
shall not be installed on roof hips.
5. Lomanco Lo-Omni Roll(LOR-30)Ridge Vent and TRI-BUILT®Lo-OmniRoll(LOR-30)Ridge Vent
shall not be connected at ridge intersection, or within 12"of any side wall or roof protrusion,with a ventilation
slot clearance of 12"from such obstructions.
6. Lomanco Lo-Omni Roll(LOR-30)Ridge Vent and TRI-BUILT®Lo-OmniRoll(LOR-30)Ridge Vent
j shall not be installed on roof mean heights greater than 33 ft.
7. For application over laminated shingles,apply a bead of silicone caulking or roof cement to the underside of
the outer baffle and at exposed edges.
8. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61 G20-3 of the Florida Administrative Code.
I
I
I
I
i
i
i
i
I
I
f
NOA No.: 18-1107.02
MAMFDADE COUNTY Expiration Date: 09/04/23
Approval Date: 01/03/19
Page 4 of 5
i
Mal �-
' a s '
3 i
3 zl
a s
a s `
#li Al.'AIP jttNCj
� a i
A.
i a S
;�la SDI¢
3 i
3 #
a S - 7
3 i 1i
� 3 # f:
60
a i
a s
S
a se
a s
;II III 41
Y a s wl
a s
a s _
i A A i!
a s
w I3 # ® o
' 3 i
i a
I a i
i
i
.6250"
j Lomanco Lo-OmniRoll(LOR-30)Ridge Vent
TRI-BUILT®Lo-OmniRoll(LOR-30)Ridge Vent
END OF THIS ACCEPTANCE
NOA No.: 18-1107.02
MIAMMADE COUNTY Expiration Date: 09/04/23
Approval Date: 01/03/19
Page 5 of 5
1
Business & Professional Regulation
BCIS Home I Log In I User Registration I Hot Topics Submit Surcharge Stats&Facts I Publications Contact Us I BCIS Site Map I_Unks I Search
�Oftd2
r ", Product Approval
,,�rirtt��ttwr*eevn a USER:Public User
8P7.^.r1aF�3¢m
. Product Approval Menu>Product or Application Search>Aoplication List>Application Detail
• FL# FL16048-R6
I Application Type Revision
Code Version 2017
II i Application Status Approved
A I Comments
Archived
i
Product Manufacturer Tri-Built Materials Group,LLC
Address/Phone/Email PO Box 70
Rutherford,NJ 07070
(800)516-1485
david.ruiz@tribuiltmg.com
Authorized Signature David Ruiz
david.ruiz@tribuiltmg.com
Technical Representative David Ruiz
Address/Phone/Email 250 Route 17 North
East Rutherford,NJ 07073
(201)842-2449
david.ruiz@tribuiltmaterialsgroup.com
Quality Assurance Representative
I
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
J Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 07/18/2020
Validated By John W.Knezevich, PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL16048 R6 COI 2017 01 COI Nieminen.pd�
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
ASTM G155 2005
FM 4474 2011
FRSA/TRI April 2012(04-12) 2012
UL1897 2012
Equivalence of Product Standards
Certified By
i
f
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 09/25/2017
Date Validated 10/01/2017
Date Pending FBC Approval 10/03/2017
Date Approved 12/12/2017
Summary of Products
� FL# Model,Number or Name Description
16048.1 TRI-BUILT Roof Underlayments Self-adhering,modified bitumen roof underlayments
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16048 R6 II 2017 09 FINAL ER TRI-
Approved for use outside HVHZ:Yes BUILT UNDERLAYMENTS FL16048-R6.p!if
Impact Resistant:N/A Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-150 Created by Independent Third Party:Yes
Other: 1.)The design pressure noted herein pertains to use of Evaluation Reports
foam-on tile systems overtop the self-adhering underlayment FL16048 R6 AE 2017 09 FINAL ER TRI-
for one particular application.See ER Section 5.6.4 for details. BUILT UNDERLAYMENTS FL16048-R6.122f
2.)Refer to ER Section 5 for other Limits of Use. Created by Independent Third Party:Yes
I
Back Next
I
I
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility,Statement::.Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.4B7.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
® ® d:Fik M
Credit Card
Safe
I
I
i
EXTERIOR RESEARCH&DESIGN,LLC.
Certificate of Authorization#9503
TRINITYQO ERD 353 CHRISTIAOXFORD,,CT 6478
i I
(203)262-9245
EVALUATION REPORT
TRI-BUILT Materials Group,LLC Evaluation Report A42960.10.12-R6
PO Box 70 FL16048-R6
Rutherford, NJ 07070 Date of Issuance:10/25/2012
(800)516-1485 Revision 6: 09/25/2017
i
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
f construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for-use of the product under the 'Florida Building Code and Florida Building Code, Residential Volume. The
j products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: TRI-BUILT Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
i
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
I changes or the referenced Quality Assurance documentation changes. TrinityI ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
1 Prepared by:
I � -
• F `. T ram::
P.E.
', Syly\�,-'•s`}�. The facsimile seal appearing was authorized by Robert Nieminen,
Florida Registration No.59166,Florida MCA ANE1983 P.E.on 09/25/2017.This does not serve as an electronically signed
Robert J.M.Nieminen
document.
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
j 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
j product.
5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
-f'RINITYJ ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: TRI-BUILT Roof Underlayments, as produced by TRI-BUILT Materials Group, LLC, have
demonstrated compliance with the following sections of the 6`h Edition(2017) Florida Building Code through testing
in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/
Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1504.3.1 Wind Resistance FM 4474 2011
1504.3.1 Wind Uplift UL 1897 2012
1504.6 Accelerated Weathering ASTM G155 2005
1507.2.4/1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015
1507.3.3 Physical Properties FRSA/TRI April 2012(04-12) 2012
3. REFERENCES:
Entity Examination Reference Date
ERD(TST6049) Physical Properties S40540.02.13-1 02/19/2013
ERD(TST6049) Physical Properties S40540.11.13 11/19/2013
ERD(TST6049) Physical Properties S40540.03.14 03/26/2014
ERD(TST6049) Physical Properties S44870.04.14-2 04/02/2014
ERD(TST6049) Physical Properties S44870.04.14-3 04/02/2014
ERD(TST6049) Physical Properties S44870.04.14-1 04/10/2014
ERD(TST6049) Physical Properties S44870.04.14-4 04/10/2014
ERD(TST6049) Physical Properties S43530.02.14-1-R1 05/14/2014
ERD(TST6049) Physical Properties S43530.05.14 05/28/2014
ERD(TST6049) Physical Properties S40540.10.14 10/31/2014
ERD(TST6049) Physical Properties SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SC8520.04.15 05/27/2015
I ERD(TST6049) Wind Resistance SC14045.05.17-R1 06/07/2017
UL,LLC.(QUA9625) Quality Control Multiple-Listing R16814 12/10/2015
! UL,LLC.(QUA9625) Quality Control Service Confirmation Exp.07/18/2020
I
4. PRODUCT DESCRIPTION:
4.1 CTri=Built Sand-R SA Shingle Underlayment is aself-adhering, glass-mat reinforced, sand-surFaced;SBS
modified bitumen roof underlayment,with a 36-inch sheet width;meet`s ASTM D1970
4.2 Tri-Built S/A HT TU Underlayment is a self-adhering, non-woven polyester fabric surfaced, SBS modified
bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI April 2012.
4.3 Tri-Built Smooth HT S/A Underlayment is a self-adhering, glass-mat reinforced, film-surfaced, SBS
modified bitumen roof underlayment;meets ASTM D1970.
S. LIMITATIONS:
I
j 5.1 This is a building code evaluation. Neither Trinity[ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
i
used for permitting or design guidance unless retained specifically for that purpose.
j 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design,U.C. Evaluation Report A42960.10.12-R6
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6:09/25/2017
Page 2 of 6
TRINITY 4 ERD
5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is
i specifically referenced within FBC approval documents. If not listed, a request may be made to the
Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the
prepared roof covering.
5.5 Allowable Roof Covers:
TABLE 1: 'ROOF COVER OPTIONS
Underlayment Asphalt Nail-On Tile Foam-On Tile Metal Wood Shakes Slate
Shingles &Shingles
tTri-Built Sand-R.SA'Shingie
Underlayment) )Yes (NVoI No No Yes Yes
Tri-Built S/A HT TU Yes Yes Yes Yes Yes Yes
Underlayment See 5.5.1
I
Tri-Built Smooth HT S/A
Underlayment Yes No No Yes Yes Yes
5.5.1 "Foam-On Tile"is limited to use of the following Approved tile adhesives/underlayment combinations.
TABLE-1AIALLOWABLE TILE ADWESIVE/UNDERLAYMENT COMBINATIONS)
Adhesive Florida Product Approval Underlayments
i
ICP Adhesives Polyset®AH-160 FL6332 Tri-Built S/A HT TU Underlayment
Dow TileBond'" FL22525 Tri-Built S/A HT TU Underlayment
5.6 Allowable Substrates:
j 5.6.1 Direct-Bond to Deck:
Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine;ASTM D41
primed Southern Yellow Pine;ASTM D41 primed structural concrete.
I
While not required over plywood,OSB or Southern Yellow Pine substrates,TRI-BUILT Materials Group,LLC
recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note:
TRI-BUILT Materials Group, LLC requires tongue-and-groove board decking be covered with plywood or
i -OSB prior to installation of the self-adhering underlayment.
i
5.6.2 Bond-to-Insulation:
Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
i ➢ Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam-on tile systems (Tri-Built S/A HT TU Underlayment only), insulation attachment shall be
i designed by a qualified design professional and installed based on testing of the insulation/underlayment
system in accordance with FM 4474,Appendix D or TAS 114,Appendix J.
r ,
I
i
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
Exterior Research and Design,LLC. Evaluation Report A42960.10.12-116
Certificate of Authorization#9503 CH EDITION(2017)FBC NON-HVHZ EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6:09/25/2017
Page 3 of 6
TRINrrY ERD
f5.6.3 Bond to Mechanically Attached Base Laver:
Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
1 Underlayment applied to:
9 ASTM D226,Type I or II felt.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam-on tile systems (Tri-Built S/A HT TU
Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRI April 2012(04-
12).
j 5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where
the underlayment forms part of the load-path. The following wind uplift limitations apply to direct-deck
underlayment systems that are not addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile
applications. Maximum Design Pressure is the result of testing for wind load resistance based on
allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety
per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012(04-12),Appendix A,Table 1A or
FBC 1609 for determination of design wind pressures.
#1 Maximum Design Pressure=-45.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional)ASTM D41 or RESISTO EXTERIOR PRIMER
I
Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered.
#2 Maximum Design Pressure=-67.5 psf:
I
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having
I Jurisdiction.
Primer: Soprema Elastocol 600c
Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered.
#3 Maximum Design Pressure=-150.0 psf:
j Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit
adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp
splinters and wood projections shall be removed/sanded.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Underlayment: Tri-Built S/A HT TU Underlayment, self-adhered, shall be thoroughly roll using hand
roller and/or weighted roller to ensure there are no voids, and ensure there are no
j voids/bridging at side and end-laps.
#4 Maximum Design Pressure=-60.0 psf:
I
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Soprema Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1)
and tin caps(FBC 1517.5.2)spaced 6-inch o.c.at the 4-inch laps and 6-inch o.c. in three,
` equally spaced rows in the center of the sheet.
Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered.
j
i
I
i
Exterior Research and Design,I.I.C. Evaluation Report A42960.10.12-116
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL16048-116
TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6:09/25/2017
Page 4 of 6
TRINIWJ ERD
! 5.6.4.1 For mechanically attached Base Sheet,the maximum design pressure for the selected assembly shall meet
or exceed that required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1
j design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria.
Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing
Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in
Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements.
5.7 Exposure Limitations:
i Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left
exposed for longer than 30-days after installation
Tri-Built S/A HT TU Underlayment shall not be left exposed for longer than 180-days after installation.
5.8 Tile Slippage Limitations(TAS 103 per FRSA/TRI April 2012(04-12)):
When loading roof tiles on the underlayment in direct-deck tile assemblies,the maximum roof slope shall
be as follows. These slope limitations can only be exceeded by using battens during loading of the roof
I
tiles.
I TABLE 2: TII E'SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS',' +
a Underlayment Tile Profile Staging Method Maximum
Flat Max.10-tile stack 6:12
i Lugged Max.10-tile stack 5:12
Max.10-tile stack(bottom 2-tile stack
j shall be inverted,followed by 8 tiles high 6:12
on slope,as shown below)
Tri-Built S/A HTTU * ,�
Underlayment Lugged j
I
� a
I
I
I
I
I
i
If
I
Exterior Research and Design,I.I.C. Evaluation Report A42960.10.12-R6
Certificate of Authorization#9503 CH EDITION(2017)FBC NON-HVHZ EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6:09/25/2017
Page 5 of 6
1
I
TRINITY I ERD
6. INSTALLATION:
6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT Materials Group, LLC
published installation requirements subject to the Limitations set forth in Section 5 herein and the
specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application,and prime the substrate(if applicable).
6.3 Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
I
Underlayment:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
I 6.3.2 Non-Tile applications:
While priming is optional, TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof
cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel-off the release film diagonally while holding the
membrane tight. Firmly roll, broom or hand-press the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course below,sealed in accordance with
TRI-BUILT Materials Group,LLC requirements.
When installing at slopes above 8:12, TRI-BUILT Materials Group, LLC recommends back-nailing in the
overlap area at the top of the sheet at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths.Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction. For valleys,apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications(Tri-Built S/A HTTU Underlayment only):
f Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
For foam-on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that
fall outside the scope of FRSA/TRI April 2012(04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment. See Table 2 herein, and TRI-BUILT Materials Group, LLC published requirements for tile
staging.
7. -BUILDING PERMIT REQUIREMENTS:
f
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
I Gulfport, MS
9. QUALITY ASSURANCE ENTITY:
UL, LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
Exterior Research and Design,U.C. Evaluation Report A42960.10.12-116
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVH2 EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6:09/25/2017