Loading...
HomeMy WebLinkAboutRevisions T OFFICE USE ONLY: DATE FILED: PERMIT# C ( 00a,- O.")59 r) l^3D REVISION FEE: I J ' RECEIPT# i PLANNING&DEVELOPMENT SERVICES BUILDING&CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982.5652 (772)462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE ADDRESS: 3181 Linda Vista Ave Foit Pierce, FL 34982 DETAILED DESCRIPTION OF PROJECT REVISIONS: Doing a 1.5"Snaplock instead of 24ga. 1"Nailstrip. CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CCC1330788 ST. LUCIE CO CERT. #: BUSINESS NAME: Total Roofing Systems Specialist QUALIFIERS NAME: Juan Martinez ADDRESS: 3201 SE Dominica Terrace CITY: Stuart STATE: FL ZIP: 34997 PHONE (DAYTIME): 772-872-8030 FAX: I OWNER/BUILDER INFORMATION: NAME: Michael Sheelar ADDRESS:3181 Linda Vista Ave _ CITY: Fort Pierce STATE: FL ZIP: 34982 PHONE (DAYTIME: 772-872-8030 FAX: 772-872-8033 ARCHITECT/ENGINEER INFORMATION: I NAME: ADDRESS: CITY: STATE: ZIP: PHONE (DAYTIME): FAX: OIL as SLCCC: 9/23/09 o EV *MR Revised 06/30/17 File COPY 3111/2020 Florida Building Code Online 11 � t � BCIS Home Log In �'User Registration ( Hot Topics I Submit Surcharge Stats&Facts Publications ( Contact Us I BCIS Site Map Links ♦Search a @;� �tfff` Product Approval USER:Public User O,b zi+sSR Product Approval Menu>Product or Application Search>Application List>Application Detail a a FL# FL30751-RO Application Type New Code Version 2017 Application Status', Approved Comments Archived £.. Product Manufacturer Dynamic Metals Address/Phone/Email 3201 SE Dominica Terace Stuart, FL 34997 (772) 872-8030 juan@dynamicmetal.net I I Authorized Signature Lara]esus juan@dynamlcmetal.net Technical Representative Address/Phone/Email Quality Assurance;Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ID Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Scott Wolters Evaluation Report Florida License PE-62354 Quality Assurance,Entity Keystone Certifications,Inc. Quality Assurance'Contract Expiration Date 12/06/2026 Validated By Lucas A.Turner, P.E., MBA ✓J Validation Checklist-Hardcopy Received Certificate of Independence FL30751 RO COI DM C0I2.pdf I Referenced Standard and Year(of Standard) Standard Year TAS 100 2003 TAS 110 2003 I TAS 125 2003 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtihODErVZoFmMPWH63C9BruSyV6nDoE7iSdg7pSIHMAQ%3d%3d 1/3 3/11/2020 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 10/18/2019 Date Validated 1 10/30/2019 Date Pending FBC,Approval 10/31/2019 Date Approved 12/10/2019 Date Revised 02/14/2020 Summary of Products FL# Model,Number or Name Description 30751.1 DM Class 100 3/4"Corrugated 26 Ga. Steel 3/4"Corrugated Roof Panel Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL30751 RO II 100CSHZ Dwg_pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters FL PE#62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Installation Drawing and Eva] Report for FL30751 RO AE 100CSHZ Eval2.pdf Limits of Use. Created by Independent Third Party: Yes 30751.2 DM Class 1700 1 1/2"SnapLock .032"Aluminum SnapLock 1 1/2"Standing Seam Roof Panel, 19"Wide. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL30751 RO II 17SLAL Dwg2.pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters FL PE# 62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other: Please see Installation Drawing and Eva[ Report for FL30751 RO AE 17SLAL Eval3.pdf Limits of Use. Created by Independent Third Party:Yes 30751.3 DM Class 1700 1 1/2"SnapLock 26 Ga.Galvalume SnapLock 1 1/2"Standing Seam Roof Panel, 19"Wide. (HVHZ) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL30751 RO II 1700HZ Dwg2 p-f Approved for use outside HVHZ:Yes Verified By: Scott Wolters FL PE# 62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other: Please see Installation Drawing and Eval Report for FL30751 RO AE 1700HZ Eval2.Rdf Limits of Use. Created by Independent Third Party:Yes 30751.4 DM Class 1700 1 1/2"SnapLock 26 Ga. Galvalume SnapLock 1 1/2"Standing Seam Roof Panel, 19"Wide. Limits of Use Installation Instructions Approved for use in HVHZ: No FL30751 RO II 1700SL Dwg2.pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters FL PE#62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Installation Drawing and Eva[Report for FL30751 RO AE 1700SL Eval2.pdf Limits of Use. Created by Independent Third Party: Yes 30751.5 DM Class 800 1 1/2"SnapLock 0.032"Aluminum SnapLock 1 1/2"Standing Seam Roof Panel, 15 1/2"Wide. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL30751 RO II 800SLAL Dwg2.pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters FL PE# 62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other: Please see Installation Drawing and Eva] Report for FL30751 RO AE 800SLAL Eval3.pd Limits of Use. Created by Independent Third Party: Yes 30751.6 DM Class 800 1 1/2"SnapLock 26 Ga. Galvalume SnapLock 1 1/2"Standing Seam Roof Panel, 15 1/2"Wide. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL30751 RO II 800SL Dwg2.pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters FL PE#62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other: Please see Installation Drawing and Eval Report for FL30751 RO AE 800SL Eval3.pdf Limits of Use. Created by Independent Third Party:Yes Back FNext https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtihODErVZoFmMPWH63C96ruSyV6nDoE7iSdg7pSlHMAQ%3d%3d 2/3 M , I WOLTERS ENGINEERING ENGINEERING,DRAFTING,CONSULTING 15211 971h Road N West Palm Beach,FL 33412 Ph/Fx:(561)225-1982 PRODUCT EVALUATION PRODUCT: DM CLASS 1700 26 GA. GALVALUME SNAPLOCK 11/2" STANDING SEAM ROOF PANEL (FLPA#30751.4) MANUFACTURER: DYNAMIC METALS, LLC 340 PIKE ROAD WEST PALM BEACH, FL 33411 To all concerned, The DM Class 1700 Series 26 Ga. Galvalume SnapLock 1 1/2"Standing Seam Roof Panel, manufactured by Dynamic Metals LLC, is.a non-structural galvalume coated Fluropon painted steel roof panel (50ksi min)that meets the requirements of;Section 1507.4 of the 6th Edition (2017) Florida Building Code. The panel has been tested per TAS 100 and UL 580 by Intertek with results shown in test reports K1304.04-450-18 and K1304.01-450- 18, and per TAS 110 by PRI Construction Materials Technologies, with results shown in test reports VLS-004-02-01 and VLS-005-02-01. I Technical Documentation: 1. Drawing "170OSL'dated 10/17/19, signed and sealed by Scott Wolters, PE. 2, Test Reports listed above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE, and by PRI Construction Materials Technologies, signed and sealed by Zachary R Priest, PE. 3. Supplemental'Calculations to support"1700SL"drawing, signed and sealed by Scott Wolters, PE. I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). Based on the limitations listed below and those provided in the documents above, this product meets all the requirements of the 6th Edition (2017) Florida Building Code generally, and chapter 1.5 specifically, for use outside of the HVHZ. Limitations: This panel is approved for use outside of the HVHZ. Overall Limitations: Maximum Panel Width: 19" (nominal) Minimum Rib Height: 11/2" Clip Anchors: 18 Ga. Steel,31/2" long Min. Slope: Yd12 (With Lap Sealant) 3/12 (No Lap Sealant) I 5PrCl,(k0NG IN IMPACT r,E515TANr CWTAINVV&1L 5, 5f01Q-Fp0NT5,R. w1mr/aWS I I < 3 s Max. Design Pressure: -176 psf Clip Anchor'Spacing: 4" From Ends, 18" Max, O.C. Min Panel Fasteners: #10x1" Pancake Head Fasteners, (2) per Clip i Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. (See note#2 below) Note: 1"round plastic caps may be used to prevent galvanic reactions. Underlayment: Minimum ASTM D 226 Type 11 with 4"overlaps and 6"end-laps, anchored with 12 Ga. x 1 %4'galvanized roof nails with 32 Ga. Tin caps spaced 6" O.C, in rows at the perimeter, at overlaps, and two intermediate rows staggered and spaced 12"O.C. (or) Any underlayment with a valid FLPA or Miami-Dade NOA Note: 1"round plastic caps may be used to prevent galvanic reactions. Minimum Substrate: '/z (1 5132min) 4-ply CDX Plywood, nailed to 2x rafters spaced 24"max. O.C. with 8d ring-shank nails spaced 6"O.C. Or 314"min. solid wood plank (S.G.=0.42 min) Note: The 3/"wood planking must be installed as a solid deck and must be nailed or fastened in a manner equal to the deck above, or as specified by a Florida licensed Architect/Engineer. Other Limitations: 1, Roof slope must meet requirements of FBC Sections 1507.4.2 or 1515.2. 2. Fire classification is not a part of this evaluation. Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 3. Design of substrate is by others and is not a part of this evaluation, ; S" Gj' ,IZiNIN IMPACT p5f CUAINVr. 5, O �'O[1FT'5, &WIN19OW5 i 4. Rational analysis, provided by a Florida Iicensed'Architect/Engineer per FAS 61 G20.3.005(e), may be used for project specific approval by the local authorities having jurisdiction, 5. All panels shall be permanently labeled with the manfacturer's name and/or logo, and the following statement, "Dynamic Metals FL#30751,4, DM Class 1700 Panel Forming: These panels may be jobsite roll formed with the following Dynamic Metals machines, per approval of.3rd party QA provider,.to the dimensions shown on Drawing 1700SL:. i SSQ-6800617 SSQ-5150216 SSQ-6810617 SSQ-6690517 SSQ-.4560615 SSQ-8681118 5VC-0490718 5VC-0360516 5VC-0521218 i Re-Roofing: The DM Class 1700 Series 26 Ga. Galvalume SnapLock 1 W' Standing Seam Roof Panel m'ay be installed over a single layer of existing asphalt shingles, provided the existing roof meets the requirements of Section 1511 of the Florida Building Code. if you have any questions or need more information concerning this approval please contact me. o��ea�sairi°t�� Thank you, ,�``Gd � .W��TF�O''•,� 4�. g••.��G E N S ,9S No 62354 e; ll v V 1 Scott Wolters =b FL PE# 62354 :5) STATE of ' � U• .� V OCT 20 2019 s`,� .; 40 � ,pP. •\. 4� N'`` 1S�.```,� i i 5pFCIkiziNG IN Imr/P crr,�5i5rr`rCLlRrAIR," `NA.5, 5rixr-_mowr5, & WINDG'W5 1 a h 1^ DM CLASS 1704 26 GA. STEEL SNAPL C 9 � I i i Iw i 1 1J2" STANDING SEAM ROOFING PANEL � m H IV PANEL.WIDTH p rh o ., D. '.'3:�tttk Z 41 'p 41ira�:g5�c�t x3 /j10xi" PANCAKE HEAD, n� . 111NIMUb4 1 2". 4—PLY FAS'';'N al RS, (2)PER CUP / (SEE EVAI REPORT FOR fig,p 'PL YWO00.qr 3/4" SOUD"WOOR CUP SPACING) Qdv PLANK (SEE.ltlN SAUBSTRATE NOTES IN EVAL REPORT). c ehE c c; c V w G a Q 18.GR.GALV. STEEL 'CLIP M a 19" (NOMTIN7iQ- PANEL.,PROFILE. 17QOSL 1ft