Loading...
HomeMy WebLinkAboutProduct Approval - MetalLocke Bowden, P.E. 9450 Alysbury Place Montgomery, AL 36117 Atlantic Metal 11 of Vero Beach 4310 45`h Street Vero Beach, FL 32966 772-492-8493 Products: FL 17796.1 -FL 17796.6 for Atlantic Metal Ii of Vero Beach Validation of Product Compliance Manufacturer: Atlantic Metal II of Vero Beach Product: All roofing products listed under FL 8646, FL 17796.1 thru 17796.6 January 23, 20I7 These roofing products have testing per code protocol to be compliant with Florida Building Code 2017 6" ed., for application as referenced under a Product Approval; FL 17796.1-17796.6. Product List: 1.5 Nail Strip min. 24 GA 1.5 Snap Lock min. 24GA 1.0 Mechanical Lock 0.032 or 0.040 Aluminum 1.0 Nail Strip min. 24GA :..0 Snap Lock min. 24GA — —�-5 V Crimp 26GA or 24GA are compliant under the FBC 2014 FBC 5`h ed. and FBC 2017 61h ed. with Florida Product Approval and are compliant with Rule #61G20-3. All product testing is compliant with Code Testing Requirements. Products may be permitted and installed which follow the specifications and within the parameters of the Attached Evaluation Reports listed under FL 17796.1 thru FL 17796.6. Product Evaluation reports and Keystone Qua`j%6� War ce Certificate are attached herewith this Product Compliance. Locke Scw4a, P.E. FL Reg #�h+ STATE OF Certificate of Particiation Is Hereby Granted to: Atlantic Metal II of Vero Beach, Inc. 4020 43rd Ave. Vero Beach. FL 32960 To attest the manufacturer is a licensed participant in the Keystone Quality Assurance Program Licensee No: 1032 Scope of Licensure: FPA Expires: 06/11/25 r I KEYSTOh[� Granted: June 11, 2015 Ongoing program licensure may be verified at Jon Hill, President www, keystonecerts. com 4310 45" Street Vero Beach, FL 32966 (772)257-5730 ProductFlorida i,. . •..Method: Compliant with Florida Building Code 2017 (6ei ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant Quality Assurance Program: FBC Sections: 1504.3.2, 1506, 1507.4.3, 1517, 1518.9, 1523.6.5.2.4 Underlayment: See Section 1507, Table 1507.1.1 24GA steel, ASTM A792 unpainted or painted w/ Valspar Fluropon or ASTM A653 G90 conforming to FBC 2017 61 ed. Min. 50ksi 15 X" Wide Female Rib. 1 %" tall Male Rib: %" tall rib w/ slotted strip Panel Seam: Snap Lock Panel Fastener: Corrosion Resistant Compliant; ALL to penetrate min. X" through plywood Through Panel Slot: (1) #12-11 x 1" tall Pancake Type A In Pan of Panel: (2) #10-11 x 1" Eclipse Head Type A FOR HVHZ Construction: 19/32" or greater APA Plywood or wood plank. In reroofing applications add 15/32" plywood where roof is less than 19/32" thick (min. 15/32") the attachment of the decking shall be no less than 8D annual ring shank nails@ 6"o.c. FOR NON-HVHZ Construction: min. 15/32" APA Plywood over supports at max. 24" o.c. Fire Barrier: Any approved fire barrier havin a current NOA. **Design Pressure: Panel Slot Fastener Spacing: Panel Pan Fastener Spacing: -78.5 PSF 11" O.C. N/A -116 PSF 6 34" O.C. 12" O.C. 24GA steel, ASTM A792 unpainted or painted w/ Valspar Fluropon or ASTM A653 G90 conforming to FBC 2017 6'" ed. Min. 50ksi 16" Wide Rib: 1 X" Panel Seam: Snap Lock Roof Panel Clip: 1500SNS, Fixed, 18GA, 3 X" Long Corrosion Resistant Clip Fastener: (2) #12-11 Pancake Type A to penetrate min. X" thru plywood. FOR HVHZ Construction: 19/32" or greater APA Plywood or wood plank. In reroofing applications add 15/32" plywood add 15/32" plywood where roof is less than 19/32" thick (min. 15/32") the attachment of the decking shall be no less than 8D annual ring shank nails @ 6"o.c. FOR NON-HVHZ Construction: min. 15/32" APA Plywood over supports at max. 24" o.c. Fire Barrier: Any approved fire barrier having a current NOA. _ **Design Pressure: Clip Spacing: Fasteners per Clip: -86.0 PSF 24" O.C. 2 -108.5 PSF 12" O.C. j 2 -116.0 6" O.C. 2 .032' or .040" Aluminum, 3105 H-24 unpainted or painted with Valspar Fluropon conforming to FBC 2017 6' ed. Min. 22.7 ksi 16" Wide Rib Height: 1" Panel Seam: 180' Seam, Double lock w/ mechanical seamer Roof Panel Clip: UC -3 Stainless Steel Butterfly Clip Assembly, Two -Piece Slider Corrosion Resistant Clip Fastener: (2) #12-11 x 1" Pancake Type A to penetrate min. %" thru plywood FOR HVHZ Construction: 19/32" or greater APA Plywood or wood plank. In reroofing applications add 15/32" plywood where roof is less than 19/32" thick (min. 15/32") the attachment of the decking shall be no less than 8D annual ring shank nails @ 6"o.c. FOR NON-HVHZ Construction: min. 15/32" APA Plywood over supports at max. 24" o.c. Fire Barrier: Any approved fire barrier having a current NOA. **Design Pressure: Clip Spacing: Fasteners per Clip: -63.5 PSF 24" O.C. 2 -101.0 PSF 6" O.C. 2 24GA Steel, conforming to FBC 2017 a ed. Yield Strength: Min. 50 ksi 16" Wide Female Rib: 1" tall Male Rib: N" tall rib w/ slotted strip Panel Seam: Snap Lock Panel Fastener: Corrosion Resistant Compliant; ALL to penetrate %" min. through plywood Through Panel Slot: (1) #10-13 x 1" GP Pancake Type A In Pan of Panel: (2) #10-11 x 1" Eclipse Head Type A Substrate: Min. 15/32" APA Plywood over supports at max. 24" o.c. Min. slope shall comply w/ FBC 2017 6' ed. i "Design Pressure: Panel Slot Fastener Spacing: Panel Pan Fastener Spacing: -59.75 PSF 16" O.C. N/A -101.0 PSF 6 %" O.C. N/A -153.5 PSF 6 %" O.C. 12" O.C. 246A steel, ASTM A792 unpainted or painted w/ Valspar Fluropon or ASTM A653 G90 conforming to FBC 2017 6u' ed. Min. 50ksi 17" Wide Rib Height: 1" Panel Seam: Snap Lock Roof Panel Clips: 1000SNS, Fixed, 18GA, 3 X" Long Corrosion Resistant Clip Fastener: (2) #12-11 Pancake Head Type A to penetrate min, X" through plywood FOR HVHZ Construction: 19/32" or greater AAA Plywood or wood plank. In reroofing applications add 15/32" plywood where roof is less than 19/32" thick (min. 15/32") attachment of the decking shall be no less than 8D annual ring shank nails @ 6"o.c. FOR NON-HVHZ Construction: min.15/32" APA Plywood over supports at max. 24" o.c. Fire Barrier: Any approved fire barrier having a current NOA. Min. slope shall comply w/ FBC 2017 6th ed. **Design Pressure: I Clip Spacing: Fasteners per Clip: -67.3 PSF 24" O.C. 2 -131.0 PSF 6" O.C. 2 4 24GA or Min. 26GA Steel, ASTM A792 coated w/ Fluropon or ASTM A653 G90 conforming to FC 2017 6th ed. Min. 50 ksi 24" Wide Rib Height: 3/8" major rib Fire Barrier: %" Georgia Pacific "Dens Deck" or approved equal. FOR HVHZ Construction: 19132" or greater APA Plywood or wood plank. In reroofing applications add 15/32" plywood where roof is less than 19132" thick (min. 15132") the attachment of the decking shall be no less than 8D annual ring shank nails @ 6"o.c. FOR NON-HVHZ Construction: min. 15/32" APA Plywood over supports at max. 24"o.c. Min. slope shalt comply wJFBC 2017 6th ed. **Design Pressure: I Fastener Pattern: Fasteners acing: -108.5 PSF Panel Rib 12" O.C. -156.5 PSF Panel Rib 6" O.C. 1 Reference Data: "DESIGN PRESSURE INCLUDES A SAFETY MARGIN OF 2:1 1 Force Engineering & Testing (TST-5328) 72-019OT-07 TAS 125-03 (UL 580-061/UL 1897-122) j Farabaugh Engineering & Testing (TST-1564) T349-07 TAS 100-95 PRI Asphalt Technologies TAS 110-00 (ASTM G 155/ASTM B 117) Force Engineering & Testing (TST-5328) 72-01807-07 TAS 125-03 (UL 580-061/1-11- 1897-122) Farabaugh Engineering & Testing (TST-1654) T107-07 TAS 100-95 Force Engineering & Testing (TST-5328) 72-0191T-07 TAS 125-03 (UL 580-061/UL 1897-12- Farabaugh Engineering & Testing (TST-1654) T232-07 TAS 100-95 i Force Engineering & Testing (TST-5328) 72-0314T-06 UL 580-941/UL 1897-122 Farabaugh Engineering & Testing (TST-1654) T158-07 TAS 100-95 1 1 Force Engineering & Testing (TST-5328) 72-021OT-07 TAS 125-03 (UL 580-061/UL 1897-122) Farabaugh Engineering & Testing (TST-1654) T233-07 TAS 100-95 Force Engineering & Testing (TST-5328) 115-0172T-07 A -C TAS 125-03 (UL 580-061/UL 1897-122) Farabaugh Engineering & Testing (TST-1654) T130-07 TAS 100-95 T215-08 TAS 100-95 1. UL 580-94 test standard is equivalent to UL 580-05 teststandards. 2. UL 1897-98 test standard Is equivalent to UL 1897-12 test standards. j Limitations: - Underlayment to be compliance with current Florida Building Code (FBC}2017 61" ed.. see Chart 1507.1.1 2. 'vlinirnum slope to be compliant with Florida Building Code 2017 6'h ed., and per with Manufacturer's installation reference. 3. Products are compliant with State of Florida product approval per Rule 61G20-3. Compliance Niethod: 1-D 4. Engineering analysis for "project specific approval by local authority's w/Jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. G. Support framing in compliance w/FBC 2017 61h ed., Chapter 22 Steel, Chapter 23 Wood and Chapter 16 Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. Certificate of Independence: Locke Bowden, P.E. does not have, not will acquire a financial interest in any company manufacturing or distributing products under this evaluation. Locke Bowden, P.E. isnot owned, operate(k41 FftXr4 by any company, manufacturer or distributing products under report. ♦p�.• 1.0 SF •.F�y'. Locke Bowden, P.E FL Reg. no. 49704 � o. 4 - • �' Z �` ' •� STATE OF `'�.SSlO N A � �r, ��• ATLANTIC METAL 11 OF VERO BEACH, INC. 5V Crimp 24GA or 26GA Min. Thru Fastened over Plywood — INSTALLATION DETAILS 5-V CRivIP EXPOSED FASQTE:',ER 9Y8TG.--,A 6" (D.C. L- -;;PSTRUCTUR�: MATEFM. rFrrDJN'-q CIF%' -'is sm n --S' f�vmjs -N! z Y -r ZW PRal/TZE FJLL WSM CM.C9 5: ,-V.,*=:; T-E-CFMCAL W, A. TO ?A=4 74=?=A"Y AU' VATEP-rf-, sa Z. M -17)4r YOU Rzcir-Tr• rvc rrc C14 8, 17 7— Stock 1',!,utericl FlclY' 0.09 - Fur 2 -overage 24 vpr.agp ' j L-enterRik) ATLANTIC METAL II OF VERO BEACH, INC. 5V Crimp 24GA or 26GA Min. Thru Fastened over Plywood — INSTALLATION DETAILS .IDLE 5v w' W;7 PANE', Roc -E -c F S FE n UiJT516c r 1 7APE su%LEIR CLOSURE WATERPROOF �Ac`S�iER`: Jc RIDGE OVER Y400D I?ECsK ISOMETRIC VIEW OF RIDGE OVER WOOD DECK ATLANTIC METAL II OF VERO BEACH, INC. 5V Crimp 24GA or 26GA Min. Thru Fastened over Plywood — INSTALLATION DETAILS ,. V'uC, =f Y� ;APE \r. € li i ATLANTIC METAL 11 OF VERO BEACH, INC. 5V Crimp 24GA or 26GA Min. Thru Fastened over Plywood —;NSTALLATION DETAILS WAU- ?:.NEL C7';7'sj 7 T %rATRxa ;'42M3-/ , 0 SLOPED fuvv -'0 -;p - /' <I - INC :*,v ^TL7;!C