HomeMy WebLinkAbout06120017 A. M. ENGINEERING AND TESTING,~E'/"~ 590 N.W. MERCANTILE PLACE Ja -.;0 PORT ST. LUCIE, FLORIDA 34986 W 0 6 ~ OFFICE: (772) 924-3575 FAX: (772) 924-3580 8 ÞC¡b. 4101 t. I..I.l II C fA. Ole "VQ l.¡ ,.,~ DENSITY OF SOIL IN PLACE I ¡::t, Contractor: Site: A WM Construction, Inc. 2296 North U.S. Highway One Fort Pierce, Florida 34946 Client Island Dunes, 8735· South Ocean Drive Port St. Lucie, St. Lucie County, Florida Maintenance Building Addition, Footings Report Date: Project No.: Lab No.: Technician: Page No.: Permit No.: June 6, 2007 1119 15 J. Hodges 1 of 1 . 0612-0017 Client: Field Test Results Proctor Compaction Eleva- Max Test Date Location tion Dry Probe Dry In Min Pass/ No. Tested (ft) HCP H2O Density Depth Density Place Req'd Fail % (pet) (in) (pet) (% ) (%) 1 6/5/07 East Side of Existing Building, North 0-1 40 8.9 102.8 12 106.8 96.3 95 P S ide Center 2 East Side of Existing Building, South 0-1 45 8.1 103.3 12 106.8 96.7 95 P Side, Center 3 East Side of Existing Building, East o - 1 40 7.0 1 02.6 12 106.8 96.1 95 P S ide, Center 4 West Side of Existing Building, North 0-1 50 9.4 103.7 12 1 06.8 97.1 95 P Side, Center 5 West Side of Existing Building, South 0-1 40 8.2 103.0 12 106.8 96.4 95 P Side, Center 6 West Side of Existing Building, 0-1 45 8.6 103.3 12 106.8 96.7 95 P Northwest Corner 7 West Side of Building, Southwest 0-1 40 7.4 102.7 12 106.8 96.2 95 P Corner Remarks: · Elevations are below bottom of footing. · Field density tests were performed in general compliance with ASTM 02922, Density of Soil in Place by Nuclear Methods. · Hand Cone Penetrometer (HCP) tests, in conjunction with information about the soil type, are empirically correlated to the relative density of the subsurface soils. . Laboratory Proctor maximum dry density was determined in accordance with ASTM 01557. Distribution: Client - 3 SLC Bldg Dept. - 1 Reviewed by: A. M. ENGINEERING AND TESTING, INC. h 4- 'Ó? ~ / /'- PCM/ah Paul C. Martin, P .E. Florida Registration No. 65051 \ ìServer-amelcompanyiAM DataiA WM Construction, Inc. - Various - 1119\Island Dunes - 8735 South Ocean Drive - PSL, SLC\15 - Maint. Bldg. Addition - Footings - Dens Rpt 1V HC? CD ~ ex:> ~ f (/) (]) +-' E s.... ~ s.... ap -1--1 c: (]) E ........ CO Q) s.... I- ....... -- o CJ) , Port Sf. Lucie Building Department ft~06/c2 - 00 I THIS FORM IS TO BE FILLED OUT BY PEST CONTROL COMPANY Certificate of CompliancSls-c [This is a partial treatment only and not a guarantee or w nty. S-'1/S-0 ? PERMIT NUMBER: 0 6 2001 Þ. ¡Ic ~ LlC/e cOrks °Ul)h. "'Y, f:L. LOCATION OF PROPERTY: LEGAL DESCRIPTION: SECTION: BLOCK: LOT: IPEST CONTROL COMPANyl Hu Montague COMPANY OWNE - PLEASE PRINT J TREATMENT INFORMATION I G ' ~ -0 1 DATE OF TREATMENT j)~¡'I/f.kÆ ~ CH¥~'CAL USED SIGNATURE · dSì~ CONCENTRA TION DATE President TITLE 4&0 GALLONS USED Liquid METHOD OF APPLICATION [Rodded, Soil Mixed, ETC.] 'SOIL TREATMENT COMPANY Q~ ý' Diligent Environmental Servi C öÇ>-r SOIL TREATMENT COMPANY ~ \........ ~ l ( b~ C)~\ ~~~. 4~ø ~fJf LINEAR FO TAGE OF AREA TREATED 3100 N.W. Boca Raton Blvd ADDRESS I SECOND TREATMENT INFORMATION I JB94495 SOIL TREATMENT/DACS LlCEr __ DATE OF TREATMENT CHEMICAL USED All work was done in accordance with the manufacturer's specifications and in accordance with all State and federal laws governing pesticide application. A second treatment was done on as per manufacturer's specification. If the second treatment is not required. a copy of the product label shall be included with this Certificate. CONCENTRA TION GALLONs USED Liquid METHOD OF APPLICATION [Rodded, Soil Mixed, ETC.] LINEAR FOOTAGE OF AREA TREATED Please Note: The City of Port St. Lucie does not guarantee or warranty the preconstruction soil treatment attested to in the above. The purpose of this document is to show that to the best of this Department's knowledge, the builder has satisfied the requirements of the Standard Building Code and the One and Two Family Dwelling Code for protection against termites This form must be returned to the Building Department before your final inspection is scheduled Environmental Services -¡I:-. O~, /:J -- 0 () I 7 S66.PRE. TREAT aOO-DllIGENT FAX 800-83 TermitePret State License JB TEjlMITE PRETREAT SPECIALISTS DILIGENT Notice of Preventative Treatment for Termites (as required by Florida Building Code (FBC) 104.2.6 and Broward County Chapter FBC 105.2. PEST PREVENTION I LAWN & ORNAMENTAL CARE I TERMITE SERVICES I MOSQUITO ABATEMENT SERVICE DATE ". '1., ~. 0 I TIME SERVICE ORDER NUMBER DEVELOPMENT NAME (PROJECT) STRUCTURE ADDRESS (LOT/BLOCK) crr~ STATE, ZIP CODE TREATMENT TYPE/AREA 'A. FLOATING )( MONOLITHIC o CUTOUTS 0 FOOTERS o PATIO o FRONT ENTRY o GARAGE o DRIVEWAY o STEM WALL o OTHER o ADDITION o EXTERIOR PERIMETER FOR RENEWAL TREATMENT TYPE o TAMP & TREAT ~ TREAT ONLY o FINAL D RETREAT o BORA CARE TREAMENT o BAIT STATION PRODUCT ~PROBUILD TC 0 DRAGNET AèTIVE INGREDIENT o DEMON TC o TERMIDOR TC o BORACARE o OTHER CONCENTRATION ~.25% 0.5% o .23% o OTHER _ GALLONS APPLIED 4"D ............ .... ~tlENt -.. .. .0 ........~" ... .....~~..~ ' 0 It ~...~ ... · ,":'f'.. 0 J1. . ~ .. .~. EA .--. .;:" œ L~~ . :. . Th ..~ '1:- ~ .. . ~ .. ~ ^ .. ^~ . ... ~ .~ 0 R \~. .-.1.. .. ........ ... .... 'tt .... ........... SQUARE FOOTAGE 4~ 0-() LINEAR FOOTAGE SQUARE FOOTAGE VERIFIED DYES ONO D MEASURED OR VERIFIED PER PLANS JOB READY CONDITIONS MET DYES DNO DETAILS SAFETY CONDITIONS As per 1 04.2.6 FBC - If soil chemical barrier method for termite prevention is used. Final exterior treatment shall be completed prior to final building approval. Certificate of Compliance: The building has received a complete treatment for the prevention of subterranean termites. Treatment is in accordance with rules and laws established by the Florida Department of Agriculture and Consumer Services. (Per the Florida Building Code.) If this notice is for the final exterior treatment, initial and date this line {TERMITE MONITOR INSTALLED 0 YES 0 NO} FINAL STICKER o ELECTRICAL PANEL D WATER HEATER OTHER Payment Terms: Customer's payment in full is due at time of initial service. Customer agrees that a finance charge in the amount of 18% per annum will be assessed on all unpaid balances that are not satisfied by the due date. In the event a collection process becomes necessary to recover an unpaid balance the following fees will be assessed including but not limited to: collection service fee, attorney's fee, finance charges and non-sufficient funds payment fee. Customer will be res sible for paying all costs associated with any collection process. 6 - (, ~ cl7 Date II a . 8 ~ ~ - {,OW CO\.q' 8mr lJn.' ..\.'i<t.1Ct'.'!1O": (~ æ,·w~ ,...-./ ~ NAHB ItII BOO-DiliGENT 800Diligent.com ðYJ "h Date ~ MHO( ~ Customer (Property Owner or Agent) Corporate 3100 NW Boca Raton Blvd. I Suite 106 I Boca Raton, Florida 33431 I 800.487.8190