DENSITY OF SOIL IN PLACE I ¡::t,
Contractor:
Site:
A WM Construction, Inc.
2296 North U.S. Highway One
Fort Pierce, Florida 34946
Client
Island Dunes, 8735· South Ocean Drive
Port St. Lucie, St. Lucie County, Florida
Maintenance Building Addition, Footings
Report Date:
Project No.:
Lab No.:
Technician:
Page No.:
Permit No.:
June 6, 2007
1119
15
J. Hodges
1 of 1
. 0612-0017
Client:
Field Test Results Proctor Compaction
Eleva- Max
Test Date Location tion Dry Probe Dry In Min Pass/
No. Tested (ft) HCP H2O Density Depth Density Place Req'd Fail
% (pet) (in) (pet) (% ) (%)
1 6/5/07 East Side of Existing Building, North 0-1 40 8.9 102.8 12 106.8 96.3 95 P
S ide Center
2 East Side of Existing Building, South 0-1 45 8.1 103.3 12 106.8 96.7 95 P
Side, Center
3 East Side of Existing Building, East o - 1 40 7.0 1 02.6 12 106.8 96.1 95 P
S ide, Center
4 West Side of Existing Building, North 0-1 50 9.4 103.7 12 1 06.8 97.1 95 P
Side, Center
5 West Side of Existing Building, South 0-1 40 8.2 103.0 12 106.8 96.4 95 P
Side, Center
6 West Side of Existing Building, 0-1 45 8.6 103.3 12 106.8 96.7 95 P
Northwest Corner
7 West Side of Building, Southwest 0-1 40 7.4 102.7 12 106.8 96.2 95 P
Corner
Remarks:
· Elevations are below bottom of footing.
· Field density tests were performed in general compliance with ASTM 02922, Density of Soil in Place by Nuclear Methods.
· Hand Cone Penetrometer (HCP) tests, in conjunction with information about the soil type, are empirically correlated to the
relative density of the subsurface soils.
. Laboratory Proctor maximum dry density was determined in accordance with ASTM 01557.
Distribution:
Client - 3
SLC Bldg Dept. - 1
Reviewed by:
A. M. ENGINEERING AND TESTING, INC.
h 4- 'Ó?
~ / /'-
PCM/ah
Paul C. Martin, P .E.
Florida Registration No. 65051
\ ìServer-amelcompanyiAM DataiA WM Construction, Inc. - Various - 1119\Island Dunes - 8735 South Ocean Drive - PSL, SLC\15 - Maint. Bldg. Addition
- Footings - Dens Rpt 1V HC?
CD
~
ex:>
~
f
(/)
(])
+-'
E
s....
~
s....
ap
-1--1
c:
(])
E
........
CO
Q)
s....
I-
.......
--
o
CJ)
, Port Sf. Lucie Building Department
ft~06/c2 - 00 I
THIS FORM IS TO BE FILLED OUT
BY PEST CONTROL COMPANY
Certificate of CompliancSls-c
[This is a partial treatment only and not a guarantee or w nty. S-'1/S-0
?
PERMIT NUMBER: 0 6 2001
Þ.
¡Ic ~
LlC/e cOrks
°Ul)h.
"'Y, f:L.
LOCATION OF PROPERTY:
LEGAL DESCRIPTION:
SECTION:
BLOCK:
LOT:
IPEST CONTROL COMPANyl
Hu Montague
COMPANY OWNE - PLEASE PRINT
J TREATMENT INFORMATION I
G ' ~ -0 1
DATE OF TREATMENT
j)~¡'I/f.kÆ ~
CH¥~'CAL USED
SIGNATURE
· dSì~
CONCENTRA TION
DATE
President
TITLE
4&0
GALLONS USED
Liquid
METHOD OF APPLICATION [Rodded, Soil Mixed, ETC.]
'SOIL TREATMENT COMPANY Q~ ý'
Diligent Environmental Servi C öÇ>-r
SOIL TREATMENT COMPANY ~ \........ ~ l ( b~
C)~\ ~~~.
4~ø ~fJf
LINEAR FO TAGE OF AREA TREATED
3100 N.W. Boca Raton Blvd
ADDRESS
I SECOND TREATMENT INFORMATION I
JB94495
SOIL TREATMENT/DACS LlCEr __
DATE OF TREATMENT
CHEMICAL USED
All work was done in accordance with the
manufacturer's specifications and in accordance
with all State and federal laws governing
pesticide application. A second treatment was
done on as per manufacturer's specification. If
the second treatment is not required. a copy of
the product label shall be included with this
Certificate.
CONCENTRA TION
GALLONs USED
Liquid
METHOD OF APPLICATION [Rodded, Soil Mixed, ETC.]
LINEAR FOOTAGE OF AREA TREATED
Please Note: The City of Port St. Lucie does not guarantee or warranty the preconstruction soil
treatment attested to in the above. The purpose of this document is to show that to the best of this
Department's knowledge, the builder has satisfied the requirements of the Standard Building Code
and the One and Two Family Dwelling Code for protection against termites
This form must be returned to the Building
Department before your final inspection is scheduled
Environmental Services
-¡I:-. O~, /:J -- 0 () I 7 S66.PRE. TREAT
aOO-DllIGENT
FAX 800-83
TermitePret
State License JB
TEjlMITE PRETREAT SPECIALISTS
DILIGENT
Notice of Preventative Treatment for Termites
(as required by Florida Building Code (FBC) 104.2.6 and Broward County Chapter FBC 105.2.
PEST PREVENTION I LAWN & ORNAMENTAL CARE I TERMITE SERVICES I MOSQUITO ABATEMENT
SERVICE DATE ". '1., ~. 0 I
TIME
SERVICE ORDER NUMBER
DEVELOPMENT NAME (PROJECT)
STRUCTURE ADDRESS (LOT/BLOCK)
crr~ STATE, ZIP CODE
TREATMENT TYPE/AREA
'A. FLOATING )( MONOLITHIC
o CUTOUTS 0 FOOTERS
o PATIO
o FRONT ENTRY
o GARAGE
o DRIVEWAY
o STEM WALL
o OTHER
o ADDITION
o EXTERIOR PERIMETER FOR RENEWAL
TREATMENT TYPE
o TAMP & TREAT ~ TREAT ONLY
o FINAL
D RETREAT
o BORA CARE TREAMENT
o BAIT STATION
PRODUCT
~PROBUILD TC 0 DRAGNET
AèTIVE INGREDIENT
o DEMON TC
o TERMIDOR TC
o BORACARE
o OTHER
CONCENTRATION
~.25%
0.5%
o .23%
o OTHER _
GALLONS APPLIED
4"D
............
.... ~tlENt -..
.. .0 ........~" ...
.....~~..~ ' 0 It ~...~ ...
· ,":'f'.. 0 J1. . ~ ..
.~. EA .--.
.;:" œ
L~~ . :. .
Th ..~ '1:- ~ ..
. ~ .. ~ ^ .. ^~ .
... ~ .~ 0 R \~. .-.1..
.. ........ ...
.... 'tt ....
...........
SQUARE FOOTAGE
4~ 0-()
LINEAR FOOTAGE
SQUARE FOOTAGE VERIFIED
DYES
ONO
D MEASURED OR VERIFIED PER PLANS
JOB READY CONDITIONS MET
DYES
DNO
DETAILS
SAFETY CONDITIONS
As per 1 04.2.6 FBC - If soil chemical barrier method for termite prevention is used. Final exterior treatment shall be completed prior to final building approval.
Certificate of Compliance: The building has received a complete treatment for the prevention of subterranean termites. Treatment is in accordance with rules and
laws established by the Florida Department of Agriculture and Consumer Services. (Per the Florida Building Code.)
If this notice is for the final exterior treatment, initial and date this line
{TERMITE MONITOR INSTALLED 0 YES 0 NO}
FINAL STICKER
o ELECTRICAL PANEL
D WATER HEATER
OTHER
Payment Terms: Customer's payment in full is due at time of initial service. Customer agrees that a finance charge in the amount of 18% per annum will
be assessed on all unpaid balances that are not satisfied by the due date. In the event a collection process becomes necessary to recover an unpaid
balance the following fees will be assessed including but not limited to: collection service fee, attorney's fee, finance charges and non-sufficient funds
payment fee. Customer will be res sible for paying all costs associated with any collection process.
6 - (, ~ cl7
Date
II
a
.
8
~
~
-
{,OW CO\.q' 8mr lJn.' ..\.'i<t.1Ct'.'!1O":
(~
æ,·w~
,...-./
~
NAHB
ItII
BOO-DiliGENT
800Diligent.com
ðYJ "h
Date
~
MHO(
~
Customer (Property Owner or Agent)
Corporate 3100 NW Boca Raton Blvd. I Suite 106 I Boca Raton, Florida 33431 I 800.487.8190