HomeMy WebLinkAboutProduct ApprovalFlorida Building Code Online
Page 1 of 2
'S, J d bS Ft Yv ae xr s�,�r . • k =r �Fz ��z� 4 `� NY` P�` r .. '
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats Pa Facts Publications FBC Staff BCIS Site Map Links Search
J Product Approval b"0% r
s USER: Public User
Product Approval Menu > Product._gr Ap lication_Search > Applitbtion_Ligt > Application Detail
FL #
FL10674-R13
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43659
(740)404-7829
greg. keeler@owenscorning.com
Authorized Signature Greg Keeler
g reg. keel er@owenscouning.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo, OH 43659
(419) 376-8360
mel. sa ncra nt@owenscomig. com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed Robert J.M. Nieminen
the Evaluation Report
Florida License PE -59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 05/16/2020
Validated By John W. Knezevich, PE
V Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
sections from the Code
FL10674 R13 COI 2017 01 COI Nieminen.pdf
Standard
ASTM D3161
ASTM D3462
ASTM D7158
Year
2016
2010
2011
http:f/w-ww.floridabui lding.orglprlpr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2... 1/15/2018
Florida Building Code Online
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
SF.ummary of Products
Method 1 Option D
10/10/2017
10/11/2017
10/15/2017
12/12/2017
Page 2 of 2
FL # Model, Number or Name
Description
10674.1 Owens Corning Asphalt Roofing
3 -tab, 4 -tab, 5 -tab, laminated, starter and hip & ridge
Shingles and Starters
shingles
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL10674 R13 II 2017 10 FINAL ER OC ASPHALT
SHINGLES FL10674-R13.Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert ]. M. Nieminen PE - 59166
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to ER, Section 5.
Evaluation Reports
FL10674 R13 AE 2017 10 FINAL ER OC ASPHALT
SHINGLES_ FL10674-R13.pdf
Created by Independent Third Party: Yes
Back Hent
Contact Us :: 2601 Blair Stone Road, Tallahassee Fl- 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of,Florida. :: Privacy Statement :: Access€ airy Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send
electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if
they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under
Chapter 455, F.S., please click here .
Product Approval Accepts:
7 ELIli�ws�eGhcY
%,regiit Card
Safe
http://www.11ondabuilding.org/pr/pr app dtl.aspx?param—wGEVXQwtDgtBNbEY5V%2,.. 1/15/2018
TRINITY ERD
EVALUATION REPORT
Owens Corning
One Owens Corning Parkway
Toledo, OIL 43659
(740) 404-7829
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate ofAuthorizatiorr #9503
353 CHRISTIAN STREFT, UNIT#13
OXFORD, CT 06478
(203) 262-9245
Evaluation Report 037340.02.12-1118
FL10674-R13
Date of Issuance: 02/06/2012
Revision 8: 10/09/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6ch Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1 / R905.2.6.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, RE, if the
product changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity) ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
�p.
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
`4;s��r.fitrrrry`r#' _.
S .
The facsimile seat appearing was authorized by Robert
Nizmine n, P.E an 10/09/2017. This does notserve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. TrinityIERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it Evaluates.
2. Trl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specificallyfor that purpose.
TRINITY ERR
ROOFING SYSTEM5 EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated
compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code,
Residential Volume through testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section PropertV Standard
Year
1507.2.5, R905.2.4 Physical Properties ASTM D3462
2010
1507.2.7.1, R905.2.6A Wind Resistance ASTM D3161
2016
1507.2.7.1, 8905.2.6.1 Wind Resistance ASTM D7159
2011
3. REFERENCES:
Entiy Examination Reference
Date
UL LLC (CER9626) Physicals & Wind Resistance File 82453, Vol. 3
02/15/2007
UL LLC (CER9626) Phys€cats & Wind Resistance 20120516-132453
05/16/2012
UL LLC (TST9628) Physical Properties 06CA20263
04/18/2006
UL LLC (TST9628) Wind Resistance 11CA34308
02/18/2012
UL LLC (TST9628) Physicals & Wind Resistance 4786093137
02/01/2014
UL LLC (TST9628) Wind Resistance 4786126532
02/10/2014
UL LLC (TST9628) Physical Properties Classification letter
02/13/2014
UL LLC (TST9628) Physical Properties Classification letter
10/02/2015
Miami -Dade (CER1592) FBC HVHZ Compliance Various NOAs
Various
UL LLC (QUA9625) Quality Control Service Confirmation
Exp. 05/16/2020
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic and Supreme are fiberglass reinforced, 3 -tab asphalt roof shingles.
4.1.2 Berkshire are fiberglass reinforced, 4 -tab asphalt roof shingles.
4.1.3 Devonshire" are fiberglass reinforced, 5 -tab asphalt roof shingles.
4.1.4 Duration, TruDefinition� Duration, Duration Premium Cool, TruDefinition�
Duration Designer Color
Collection, TruDefinition�Oakridge �, Oakridge and WeatherGuard6 HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Hip & Ridge Shingles:
4.2.1 Berkshirero Hip & Ridge Shingles, High Ridge, WeatherGuardz HP Hip & Ridge Shingles,
ProEdge Hip & Ridge
Shingles and DuraRidgeT" Hip & Ridge Shingles are fiberglass reinforced, hip and ridge
asphalt roof shingles.
4.3 Accessory Starter Strips:
4.3.1 Starter Strip Shingle, Starter Strip Plus and Starter Shingle Roll are starter strips for
asphalt roof shingles.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R8
Certificate of Authorization #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017
Page 2 of 9
TRINITY ERD
5.4 Wind Classification:
5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable
for use in all wind zones up to Vasd = 150 mph (V,It = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the
shingles are acceptable for use in all wind zones up to Vasa = 150 mph (V,it = 194 mph). Refer to Section 6 for
installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 16139.4.3, and a mean
roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval, or be Locally Approved per Rule 61620-3, per FBC 1507.2.3, 1507.2.4 or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following
exceptions:
Berkshire® shingles require minimum five (5) nails per shingle.
WeatherGuard® HP shingles require minimum six (6) nails per shingle,
r Devonshire*" shingles require minimum six (6) nails per shingle.
r Starter Strip Shingle and Starter Strip Plus require minimum five (5) nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing —Starter Strip Shingle and Starter Strip Plus:
Felt nderla °rn ¢nl
- Dock
Self -adhered
Weatherl ock"
/ ullciEflaymen[
Drip-
Drip edge
—Wails located
- 2' Y from eave
rf
Install first
Self-sealing adhesive
Starter Strip
positioned along eave
shingle with
G" rernnoved
Starter Strip shingle Overhangs eaves and rakes
Felt underlayrnent -', �_ ` Reck SelF,adhered
- Weathal.ock�-:
creorlaymeni
- i
Drip
Orip edge
edg:a
e
Wars fowled
2"-3" horn eave
Instar first Stmer Strip Plus �SaYi , rng adhesi..
whh6"removed - positioned along cave
Starter Strip Plus overhangs eaves and rakes VC -3 ra"
Exterior Research and Design, LLC. Evaluation Report 037940.02.12 -RS
Certificate ofAuthorizationff9SD3 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8: 10109/2017
Page 3 of 8
6.2.6 Minimum Nailing— Classic' &Supreme:
Normal Mansard or Area para
Wind Areas High Wind desvenes i.
Area para vientas normaies Areas vientos fuertas
VA) 1' Ft' z' (B)- `z" 1„7
5" Exposure
Expo:icidn
6.2.7 Minimum Nailing — Berkshires:
&Fkb t strip
Ls tira A sprkador
--- -. ■ t -----i ■ a----------- h. a I v
$1t�
V 1..
Standard Fastening Pattern
TRINITY ERD
Normal Mansard or Area ,pore
Wind Areas High Wind desvenes y
Area pars viontos nornrales Areas vientos fuertes
;2;2 CAf-
118'=E z12 w-41 i
5 G1 Exposure
iExposici6n
SnIaat strip
La firs de sefiador
,e
e
�»
•
• .��
r
N
1
1.,
i
6 -Nail Fastening Pattern
iviansara arz�>=eep3lope vaszenmg vatirern
Exterior Research and Design, LLC.
Certificate ofAutharizotian #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION
Owens Corning Asphalt Roof Shingles
Evaluation Report 037940.02.12-R8
FL10674-R13
Revision 8: 10/09/2017
Page 4 of 8
6.2.8 Minimum Nailing— Devonshire'-.
1"-- 1 711 i g•, I 8" r 8" I 7 t _�„
T�<
Ns
Gevas
- - -
5'51811 exposure Sealant location
Exposid6n de 5.518 pufg
ilhicac'ron del sellador
Standard 6 -Nail Fastening Pattern
TRINITY ERD
Nails
Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum Nailing — Duration®, Tru Definition® Duration, Duration® Premium Cool & Tru Definition
Duration Designer Color Collection:
4 -Nail Fastening Pattern
S�,`rzN�i1fE lash ng widh
Nall TygiwE
J E T2' E i2 t"
!
F'ri B U!1
� I
Standard Fastening Pattern
Fastening For Slopes Greater Than 21:42
p SureNslYlrpaaming Area Wldch
rf Neil,ryMcal
rdur 7" spot; df pzP3+afi fL ONdg :xmadc
Mansard or Steep Slope Fastening Pattern
6 -Nall Fastening Pattern
N ETyy M
t2 rf � 42
6 -Nail Fastening Pattern
�..-T,_ I
Exterior Research and Design, LLC. Evaluation Report 037940.02.12 -RS
Certificate of Authorization #950 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Root Shingles Revision 8: 10/09/2017
Page 5 of 8
TRINITY ERa
6.2.1 Minimum Nailing —TruDefinitiongOakridgeO, Oakridge®:
4 Mail Pattern
Escrrac*rna can 4 ciaws
l" T'
IT
5518" Ezpasure had$ 5 519" Exitosure
Exposidda de y S/S pulg. ell pas LCW9 Icjm de F ar/S puig.
Standard Fastenin0 Pattern
6 Nail Frattern
Esguema con 6 clavas
I-*- T2 Es— 12Nai—�
5 518" ij[pos le CIA Vi:W 5 519" Exposure
&pasFcmn de 5511?pulg. Expo sician de 5 54 put g.
Fastening for Stapes Greater Than 2112
J Sw9N�FB3 fa51®nlnq—'11th
1 Ir-Pla gra' �
i
Foup 1" Spats o1 Asph*Tt R401ing Cement
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing—WeatherGuar& HP:
6 -Nail Fastening Pattern
Single Side View
F� 2" l'7 Vhdn forbad
rw 71l�+ Mdl !Lh
Cii� ra fr lbs i Edi+
Exterior Research acid Design, LLC. Evaluation Report 037949.02.12-R3
Certificate erfAuthorization#9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R13
Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017
Page 6 of 8
TRINITYRD
6.3 Hip & Ridge Shingles:
6.3.1 Installation of Berkshire' Hip and Ridge Shingles, High Ridge, WeatherGuarda HP Hip and Ridge Shingles
and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions,
using four (4) nails per shingle. Installation of DuraRidgell Hip & Ridge Shingles shall comply with the
Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning
published information on wind resistance and installation limitations, including the use of hand -sealing for
wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturers published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing— BerkshireO Hip & Ridge and High Ridge:
Fig.9 Fig.2
Uirmion IOP vi— sitleVr
�t\z. Nall idatis
� f _._ I I -Y TOP LamMiaTet€ t—)i
� l
.=ter Y w ♦ -I
Exlmsrae � -1
-ryl
♦.�.___ - :r_._ i2^ _._...-
6.3.4 Minimum Nailing — WeatherGuard® HP Hip and Ridge:
Fig. A q Y
Ple'c�a8lrrg YJlntl `,
Nulls _...__�`�4
a
1
i Ezpasur��
r
Fig. G Hip & Ridge Shingle Fastening
Top VKY
Neils NAIL.
T'
S:, Exposure
12'
Exterior Research and Design, LLC. Evaluation Report 037440.02.12-R8
Certificate of Aathorizotion#9503 6' EDITION (2017) rBC NON-HVH2 EVALUATION FL10674-1213
Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017
Page 7 of 8
6.3.5 Minimum Nailing - ProEdge Hip & Ridge Shingles:
Prevailing
Wind Direction Seahrrt Strip
AV --r 6' Exposure
Fasten 71.x"
Cover Exposed
Fasteners with
Roof Gement
Standard i f„
Fastening
Pattern
t2" I Sealant
6" Expaaur�
6.3.6 Minimum Nailing — DuraRidge'" Hip & Ridge Shingles:
Note: The drawings below pertain to minimum, as -tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
PN,-jiing Wird Dirf,dm
t— 6iracxiandxnimnka di�v-nx
f?ira€atn dal ti�nto pru�a�ninanta
_
Hai
I i
I % i
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1 / R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC— QUA9625 ; (631) 546-2458; Kanchi.Agrawala-Dokania@ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Eualuation Report 0379d0.62,12-118
Certificate of Authorization #9503 EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-1113
Owens Corning Asphalt Roof Shingles Revision S: 10109/2017
Page 8 of 8
Top Vii
Ky
�-
V1W en pFan
Vista supertar I'I—
t
NA
f1E
....
......
ilou
Gnaw
{Mrmns�rinrj Sar.hlad"
f�
Ia
av
e � "
cv i a
V �
f`' J
f
},
�I
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1 / R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC— QUA9625 ; (631) 546-2458; Kanchi.Agrawala-Dokania@ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Eualuation Report 0379d0.62,12-118
Certificate of Authorization #9503 EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-1113
Owens Corning Asphalt Roof Shingles Revision S: 10109/2017
Page 8 of 8