HomeMy WebLinkAboutProduct Approval ! BCIS Home is Log In I User:Registration Hot Topics 1Submit Surcharge,j Stats&Fags Publications FBC-Staff - SCIS,Site Map Links : Search
UQ
s, a . Product Approval -
nt USER*'Public User RECEIVED
Product Agpraval'Menu>Product orAgoticat ar.Saarcfi>Apgikation.Cis[>Application Detail MAR
I� 'A �jo2o
IY AR 1L L
# FL# FL17443-RI ST. Lucie County, Permitting
``�`"` Application Type Revision
Code Version 2017
Application Status Approved,
Comments
Archived
Product Manufacturer I A TAYLOR ROOFING
Address/Phone/Email 302 Melton Drive
FT PIERCE;.FL 34482
(772)466-4040
kylewhite,228@aol.com �� —D
Authorized Signature Kyle Taylor � ���
kylewhite228@aol.com
CO"WE COMPLIANCE
Technical Representative
Address/Phone/Email To L U C I EU NN'
'
Quality Assurance Representative ® �L/% -
Address/Phone/Email /(� bo Zp
Category Roofing
Subcategory Metal Roofing File tL
Compliance MethodEvaluation Report.from a Florida Registered Architect or alicensed Florida
Professional Engineer
Evaluation Report-Hacdcopy'Received
Florida Engineer or.Architect.Name who developed the Locke Bowden
Evaluation Report
Florida License PE-49704
Quality Assurance Entity PRI Construction Materials Technologies,LLC
Quality Assurance Contract Expiration Date 01/23/2023
Validated By Zachary R. Priest,P.E.
Validation Checklist-Hardcopy Received
Certificate of Independence FL17443 R1 COI FL 17443 7 A Taylor 2017 Code Evai Report with Details
RSSS.P
Referenced Standard and Year(of Standard) Standard year
TAS.125 2003
UL 1897 2.0.12
UL580 2006
Equivalence of Product standards
Certified By
Sections from the Code
f
Product Approval Method Method 1 Option D
Date Submitted 01/24/2018
Date Validated. 02/14/2018
Date Pending FBC Approval 02/17/2018
Date Approved 04/10/2018
Summa of Products
FL# Model,Number or Name ;Description
__-_•— _�—___ __._..M�_____ _ _
17443 1 5 V Crimp 26GA 1J2"rib height over IS/32"APA plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No f_L17443 RI II FL 17443 3 A Taylor 2017 Code Eval Report
Approved for use outside.HVHZ:Yes With Details RSSS.pdf
Impact Resistant:N/A Verified By: Locke Bowden,P.E.49704
Design Pressure:+N/A/-124.25 Created..by Independent Third Party:Yes
Other:-129.25 @ 6"o,c.-69.25 @16"o.c.margin of safety Evaluation Reports
2:1 with 24"max.coverage install per manufacturers detail. FL17443 R1 AE Fl-17443 3 A Taylor 2f7 Code Eval Repg
j Not for use in HVHZ. 1AAh Details RSSS.g
Created by Independent Third Party:Yes
17443.2 VIGTORIAN CRIMP SHINGLE 26GA 1/2"RIB-PANELS LOCK INTO PREVIOUS PANELS;OVER
CDX/APA 15/32"PLYWOOD
s-Limits of Use — W Installation Instructions
Approved for use in HVHZ:No FL17443 R1 II FL 11443 3 A Taylor 2017 Code Eval Repor
Approved for use outside•HVHZ:Yes with Details RSSS.pdf
Impact Resistant:N/A Verified By: Locke Bowden,P.E.49704
Design Pressure: +N/A/-105 Created by Independent Third Party:Yes
Other:-105PSF margin of safety 2:1. Install per. Evaluation Reports.
manufacturer's details and in compliance with FBC 2017 6th FL17443 R1 AE FL 17443 1 A Taylor 2017 Code Eval R port
ed. Not for use in HVHZ. with Details RSSS.pd_f
Created by Independent Third Party:Yes
- 17�ek '.�sex1
Contact Us::2601 Blair Stone Road,TallahasseejL 32399 Phone:850-487-1824
The State.of Florida is an AA/EEO employer.Copvnght 2007-20135tate of Florida ::Rdvary Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.if you do not want your e-mail address released In response to a public-records request,do not send electronic
mail to this.entity.Instead,contact the office by phone or by traditional mall.Ifyou'have.any questions,please contact 850.487,1395,`Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have
one.The emalls provided may be used for etfical communication with the licensee.However email addresses are public record.Ifyou do not wish to supply a personal
address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,RS.,
please dick here..
Product Approval Accepts;
Credit Card
Safe
302 Milton Drive
Fort Pierce,FL 34962
(772)466-4040
o x . ' •r � t • a a i00 3t • '♦ ` so
Compliant with Florida Building Code 2017(6"'ed.) -
Compliant with Florida Product Approval Rule R 61G20-3
Compliant Quality Assurance Program:PRI CONSTRUCTION MATERIALS TECHNOLOGY
FBC Sections:1504.3.2,1507
SV Crimp thru fastened W rib at each panel edge and 1 fastener in the center of the panel,24"net coverage,26GA ASTM
A792,G-50,AZSS,.018,50ksi min.over min.15/32"thick COX plywood deck. Corrosion Resistant fastener#9.15 HWH with
sealing washers,metal to wood connections with fastener length to penetrate 5/16"thru substrate. Fasten along the crown
of the rib In the center of panel and along the lap.First fastener to be within,r-of panel edges. Min.8Dx2"annular ring shank
nails spaced 6"Q.C.reroofing,with less than 19/32"plywood(min.1S/32"),this attachment is to be used in addition to
existing attachment. Deck slope 2:12 or greater and shall be compliant with FBC 2017 67"ed.Underlayment:See FOC 201161
ed.,Sec 1507 Table 1507.1.1 "Design Pressure: Spacing:
=69.25 PSF 16"O.C.
-129.25 PSF 6"O.C.
26GA ASTM A792,G-50,AZSS,.018,50ksi Victorian Crimp Shingle over 15/32"COX/APA Plywood attached to roof trusses.
Corrosion Resistant.Fastener#10 x P'Zinc plated,MTW Pancake Head,installed at 2 per panel into lock seam. Panels applied
with 12"exposure,adjacent shingles inserted into lock seam of previous shingle.Deck slope 2:12 or greater and shall be
compliant with FBC 2017 6T"ed.Underlayment:See FAC 2017 V14 ed.,Sec..1507 Table.1507.1.1
"Design Pressure:
-105 PSF
"DESIGN PRESSURE INCLUDES A SAFETY MARGIN OF21
Reference Data:
TEST REPORTS
Hurricane Test Laboratory(TST-1527) #0224-0501-06 TAS 125(UL 580-941)
PRI Construction Materials Technologies(TST 5878) #FAE-023-02-01 UL 580-06/UL 1897-041
1.UL 580-94 test standards are equivalent to UL 580-06 test standards.
2. UL 1897-04 test standards ore equivalent to UL 1897-12 test standards.
Limitations:
1. Underlayment to be compliance with current Florida Building Code(FBC)2U17 67"ed..see Chart 1507.1.1
2. Minimum slope to be compliant with Florida Building Code 2017 6th ed.;and per with.Manufacturer's installation reference.
3. Products are compliant with State of.Florida product approval per Rule 61620-3. Compliance Method: 1-D
4. Engineering analysis for"project specific approval by local authorities w/jurisdiction is allowed by other registered
.engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this.report.
6. Support framing in compliance w/F8C2017 6`h ed.,Chapter 22 Steel,Chapter 23 Wood and Chapter 16 Structural Loading.
7. This report does not imply.warranty,installation,recommended product use outside of this report.
Certificate of Independence:
Locke Bowden,P.E.does not have,not will acquire a financial,interest in any company manufacturin�4{r '11%1 uting products
under this evaluation. s� rr/i
•''` 80W/} ��,,,
Locke Bowden,P.E.is not owned,operated,or controlled by any company,manufacturer;or I W rwiy tir{r er this
report. `.,``VE E '.•
v. 9
seal 10
f� 110,
�- ✓ ovFLO
•412
P
"'4,4 SS 10N�P�,��'''
5 V Crimp
Fastener-#9-15 corrosion resistant w/sealing washers
24"coverage
Fastener: #9 x 15 corrosion resistant with sealing washers
in Compliance with 2017 Florida Building Code, Section 1507
Perimeter fastening: 6"o.c.
Main Field fastening I 2"o.c. .
Panel Width: 26"
Panel Coverage: 24"maximu,m
26 GA Architectural Metal Roof panel
l
_ MINIMUM 2 FASTENERS Fastener#10x 1"
AT LOCK SEAM Zinc Plated VTW
Pancake Head
FIELD CUT 112 SHINGLE
TO CREATE STAGGERED
PATTERN
Fu VICTORIAN CRIMP
SHINGLES
i
_I
t
E
VICTORIAN CRIMP SHINGLE..:.
P �
LOCK SEAM .m Cf)'
- 0-
x I
w
9"EXPOSURE