HomeMy WebLinkAboutProduct Approval3/17/2020
Florida Building Code Online
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us - BCIS Site Map Links Search
Product Approval
dUpr (P USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
FL1850-R11
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
Product Manufacturer American Shutter Systems Association, Inc.
Address/Phone/Email 4268 Westroads Drive
West Palm Beach, FL 33407
(561)209-8263
bfeeley@easternmetal.com
Authorized Signature Bill Feeley
Irodriguez@easternmetal.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Shutters
Subcategory Accordion
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Walter A. Tillit, Jr., P.E.
Evaluation Report
Florida License PE -44167
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2020
Validated By John Henry Kampmann Jr.
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL1850 R11 COI AMERICAN SHUTTER SYSTEMS, INC. DRAWING 17-
102 CERTIFICATE OF INDEPENDENCE.PDF
Standard
Year
ASTM E1886
2005
ASTM E1996
2005
ASTM E330
2002
TAS 201,202,203
1994
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs9%2f%2ftCOhpJQoelShOCDrfdDsZb2inLQgznMcxp%2b7HAWw%3d%3d 1/3
3/17/2020
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
iummaryf of Products
Florida Building Code Online
Method 1 Option D
10/03/2017
10/13/2017
10/17/2017
12/12/2017
FL # Model, Number or Name
1850.1 ertha HV Accordion -Blade 3
IF(HVHZ) Drawing# 17-103
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Large Missile Level "D". Max span is 12'-7" for 35 psf
positive ASD load and 13'-0" for 35 psf negative ASD load for
one specific condition shown in span tables. See additional
loads and spans on engineered drawings.
Description
Extruded aluminum blades folded together thru knuckles and
retained by tracks to provide hurricane protection.
Installation Instructions
FL1850 R11 II AMERICAN SHUTTER SYSTEMS ASSOC., INC.
DRAWING 17-103 BERTHA HV ACCORDION SHUTTER
SYST..PDF
Verified By: American Test Lab of South Florida, Inc.
Created by Independent Third Party: Yes
Evaluation Reports
FL1850 R11 AE AMERICAN SHUTTER SYSTEMS ASSOC.,,
INC DRAWING 17-103 PRODUCT EVALUATION REPORT.PDF
Created by Independent Third Party: Yes
1850.2 Bertha HV Accordion Shutter Extruded aluminum interlocking blades retained by tracks (top
(Combo) - HVHZ - Drawing#17-102 and bottom) for storm protection
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL1850 R11 II AMERICAN SHUTTER SYSTEMS, INC.
Approved for use outside HVHZ: Yes DRAWING 17-102 BERTHA HV ACCORDION SHUTTER
Impact Resistant: Yes i SYSTEM.PDF
Design Pressure: N/A i Verified By: American Test Lab of South Florida, Inc.
Other: Large Missile Level "D". Max. span is 13'-2" for 30 psf Created by Independent Third Party: Yes
positive ASD load w/o window blade, 16-0" for 30 psf negative Evaluation Reports
ASD load for HV1 blade w/o window blade for conditions FL1850 R11 AE AMERICAN SHUTTER SYSTEMS, INC.
indicated on schedule #1, sheet 12. And 12'-3" for 30 psf DRAWING 17-102 PRODUCT EVALUATION REPORT.PDF
positive ASD load w/o window blade and 15'-5 for 30 psf !, Created by Independent Third Party: Yes
negative ASD load for HV2 blade w/o window blade. See sheets
number 12, 25, 28 and 28A of installation drawings for other — --
spans and pressures.
1850.3 Bertha HV Accordion Shutter - Blade Extruded aluminum interlocking blades retained by tracks (top
1 Only (HVHZ) - Drwg# 17-122 and bottom) for storm protection
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: Large missile level "D". Max, span is 16'-0" and 14'-9"
for 30 psf ASD negative load depending on centermates and
locking rod configuration for the HV1 blade, 8'-0" for +64, -72
psf load for HV blade for Keystone mountings 7'-0" for +75, -75
psf for metals stud mountings and 8'-0" for 110 psf, for HVI
and HV1A working in unison. See sheets 7, 11, 20 and 19
respectively of installation drawings for other spans and
pressures.
Installation Instructions
FL1850 R11 II AMERICAN SHUTTER SYSTEMS ASSOC. INC
DRAWING 17-122 BERTHA HV ACCORDION SYST.PDF
Verified By: American Test Lab of South Florida, Inc.
Created by Independent Third Party: Yes
Evaluation Reports
FL1850 R11 AE AMERICAN SHUTTER SYSTEMS ASSOC. INC
DRAWING 17-122 PRODUCT EVALUATION REPORT.PDF
Created by Independent Third Party: Yes
iRaltt, Nk?d
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Cgpyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statem
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
M&WO0P
https://www.floridabuiIding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs9%2f%2ftCOhpJQoeIShOCDrfdDsZb2inLQgznMcxp%2b7HAWw%3d%3d 2/3
monoa auuaing t,00e vnime
Credit Card
Safe
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs9%2f%2ftCOhpJQoelShOCDrfdDsZb2inLQgznMcxp%2b7HAWw%3d°/a3d 3/3