REPORT OF FOUNDATION PAD COMPACTION I
Site:
Mr. Jesse Streeter
517 Quincy Avenue
Fort Pierce, Florida 34950
Lot 18, Block 24, Barcelona Avenue, Fort Pierce
St. Lucie County, Florida
Foundation Pad
Report Date:
Project No:
Lab No:
Permit No:
May 29,2007
07-1315
--c:J
t:)
«:.4
~u~3
Client:
SF -08903
Density tests and Hand Cone Penetrometer (HCP) readings were made at a minimum of three locations in
the building pad. Density tests were performed in the upper one foot of fill. HCP readings were taken in
hand auger boreholes at one foot intervals from slab grade through the depth of fill. The density tests were
performed in general compliance with ASTM D 2922. The HCP test, in conjunction with information about
the soil type, is empirically correlated to the relative density of subsurface soils. .
Density Date Elevation Dry Density (pst) Percent
Test No. Tested Location (feet) In Place Proctor Compaction
1 5/25/07 Northeast Comer 0-1 112.6 114.8 98.1
2 Center Area 0-1 113.8 114.'8 99.1
3 Southwest Corner 0-1 111.5 114.8 .97.1
* All elevations are below bottom of slab.
The depth of the fill was approximately three feet. The fill should extend at least five feet beyond the
building perimeter. At the time of our testing no information was available regarding the foundation pad
setbacks.
In the locations and depths that were tested, the fill has been compacted to a minimum of 95 percent of the
modified Proctor maximum' dry density (ASTM D 1557). No soil borings were performed below the
recently placed fill.
Distribution:
Client - 3
Bldg. Dept. - 1
PCM/sc
Submitted by:
A. M. ENGINEERING AND TESTING, INC.
, /SP'í¡67
Paul C.Martin, P .E~
Florida Registration No. 65051
F: \C.O.D. Jobs\Streeter, Jesse\07-J 31 5 - Lot 18, Blk 24, Barcelona Ave, Ft Pierce - Pad w. Fill.doc