DUNKELBERGER ENGINEERING & TESTING, INC.
.... .::::. .> . SUI·t,·'ÐSNSITV····,'rEST. ..REPORT .......
..:...
Project Name: Momingside Report Date: 06-21-07
St. Lucie County, Florida Lot No.: ] 14
Client Name: Centex Homes F)JJr:¿]:';'(~~~=: Iv-f~:D l Permit No.: SLC 0702-0302
3301 Quantum Boulevard, First Project No.: 06-] 0-2402
Boynton Beach, FL 33426 ; JUN Z 1 2007 I Date Tested: 06-2 ] -07
¡Technician Initials: AJR
Aftn: Mr. David Donvito ;B') r Sheet No.: 1 of 1
La bora to,ry Proctor: Field,'£:ests
Minimum
Probe Maximum Optimum Dry Cone Req u ired Percent
Test Depth Dry Density Moisture Density Resistance1 Moisture Compaction Maximum Test
No. (in) (pet) (0A» ) (pet) (tst) (O~) (% ) Density Result
1 12 120.0 10.0 116.8 - - - 8.7 95.0 97.3 Pass
2 12 120.0 10.0 116.5 - - - 9.0 95.0 97.1 Pass
3 12 120.0 10.0 117.3 - - - 8.5 95.0 97.8 Pass
4 12 120.0 10.0 116.0 - - - 9.9 95.0 96.7 Pass
Type of Field Density Test:
Minimum Required Compaction Based on:
IC t- t- d fr
() ASTM D ] 556 (X) ASTM D 2922
(X) AASHTO T-180 (ASTM 0 1557)
d- b - d - h B - d K-I
() ASTM D 2937
() AASHTO T-99 (ASTM 0 698)
M d 1 S 214 h d h Id t t
ompac Ion percent es Imate om cone penetrometer rea Ing 0 tal n e WIt a ralnar - I man 0 e - an - e cone Qene rome ere
,·~est Soil
N,o.,··' Type Elevation Test:LQcation:> ..Lot .114,·94'55'Wlndrift.Circle
1 2 0-12 Lot No. 114, approximate center of house (slab subgrade)
2 2 0-12 Lot No. 114, approximate center of garage (slab subgrade)
3 10 0-12 Lot No. 114, east side of house (footing subgrade)
4 10 0-12 Lot No. 114, west side of house (footing subgrade)
Elevation Referenced to:
( ) NGVD
( ) MSL
(X) Other
Tests 1-2: Inches below top of slab subgrade.
Tests 3-4: Inches below top of footing subgrade.
,Soli T e
1 Structural Fill
2 Final Grading Fill
3 Mass Grading Fill
4 Utility Backfill - Sanitary
5 Ut~l~ty Backfill - water.., .. /'?Jp --;.~/.I y .'
6 Utlhty Backfill- Storm / (r, .' '..'"
7 Roadway Subgrade /~cf' ~. . . . -è 1
8 Stabilized Subgrade v-/". aìg E. Dunkelberger, P .E. ,/ ,I
9 Base Course FL R~fjrfa201.J93q·IJ~ ¡
10 Other: Footin Sub rade J . /¡j' ,
Note: The original of this report was signed and sealed by a registered engineer in accordance with Rule 61 G 15-18,011 of the Florida Adrninistrative Cofçf
This report is submitted as the confidential property of our client and authorization for publication of statements, conclusions or extracts from or rlgarding
this report is reserved pending our written approval. The above-referenced testing was performed at the locations and depth interval described therein on
the associated report date. No other warranties with regard to subsurface exploration, recommendations or design are expressed by this firm.
607 NW Commodity Cove, Port St. Lucie, Florida 34986 . Phone: (772) 343-9787 . Fax: (772) 343-9404
State of Florida Board of Professional Engineers Authorization No. 6870
cc: CJ ¡ent.. . ( 1 )
Centex Homes, Eric Otto (site trailer). _ _ (2)
S1. Lucie County, Building Inspections_ _ _ (1)