Loading...
HomeMy WebLinkAbout07030184 ()~~T DUNKELBERGER ENGINEERING & TESTING, INC. SOIL DENSITY TEST REPORT Project Name: Momingside Report Date: 06-19-07 St. Lucie County, Florida Lot No.: 208 Client Name: ~;~~e~:a~~: Boulevard, First~o~;CEIVED Permit No.: SLC-0703-0 184 Project No.: 06-1 0-2402 Boynton Beach, FL 33426 ;! ~ N 1 9 2007 Date Tested: 06- ] 9-07 ..... OJ . Technician Initials: AMR Atto: Mr. David Donvito ~.,; ~,~ t~')lic Works Sheet No.: 1 of 1 ~- ,.' . ' ._ w _ ,-- Laboratory Proctor - ',_ . .1 . _' .I' L- Field Tests Minimum Probe Maximum Optimum Dry Cone Required Percent Test Depth Dry Density Moisture Density Resistance1 Moisture Compaction Maximum Test No. (in) (pet) (% ) (pet) (tst) (% ) (%) Density Result 1 12 120.0 10.0 120.5 - - - 8.2 95.0 100 Pass 2 12 120.0 10.0 120.7 - - - 8.7 95.0 101 Pass 3 ]2 120.0 10.0 120.0 - - - 8.5 95.0 100 Pass 4 ]2 ] 20.0 10.0 120.2 - - - 8.0 95.0 100 Pass Type of Field Density Test: Minimum Required Compaction Based on: Ie· · d f1 () ASTM 0 1556 (X) ASTM D 2922 (X) AASHTO T-180 (ASTM D 1557) d· b· d · h B· d K·l () ASTM D 2937 () AASHTO T-99 (ASTM D 698) M d 1 S 214 h d h ld ompactlon percent estimate rom cone penetrometer rea Ing 0 talne WIt a ralnar - 1 man 0 e - an - e cone penetrometer. Test Soil I No. T,ype Elevation Test Location :L.ot 208,9430 Win d ri.ftCircle 1 2 0-12 Lot 208 at approximate center of house (slab subgrade) 2 2 0-12 Lot 208 at approximate center of garage (slab subgrade) 3 ]0 0-]2 Lot 208 at east side of house (footing subgrade) 4 10 0-12 Lot 208 at west side of house (footing subgrade) Elevation Referenced to: ( ) NGVD ( ) MSL (X) Other Tests 1-2: Inches below top of slab subgrade Tests 3-4: Inches below top of footing subgrade SoilT .': 1 Structural Fill 2 Final Grading Fill 3 Mass Grading Fill 4 Utility Backfill- Sanitary 5 Utility Backfill - Water 6 Utility Backfill - Storm 7 Roadway Subgrade ' 8 Stabilized Subgrade Craig E. Dunkelberger, P.~: ' 9 Base Course FL Reai¡üat:iDIh"N~~t 1 10 Other: Footin Su b rade .J\J1t j. P 1liiI/,', Note: The original of this report was signed and sealed by a registered engineer in accordance with Rule 61 G 15-18.0 II of the FJorida Administrative C e. This report is submitted as the confidential property of our client and authorization for publication of statements, ~onclusions or extracts from or regarding this report is reserved pending our written approval. The above-referenced testing was performed at the locations and depth interval described therein on the associated report date. No other warranties with regard to subsurface exploration, recommendations or design are expressed by this finn. cc: Centex Homes, David Donvito...(I) Centex Homes, Eric Otto (site trailer)...(2) St. Lucie County, Building Inspections...(I) 607NWCönl'ß)odityCove,iPørtSt.Lucie,.Florida34986ePhöne: (772) 343-9787 e Fax: (772}343-9404 State ofFl()rida Board of ProfessionaL Engineers · Authorization No · · 6870 8t Lucie County Inspections 2300 Virginia Avenue Ft Pierce, FL 34982 (772) 462-2172 I. CERTIFICATE OF TERMITE TREATMENT CONSTRUCTION SOIL TREATMENT PERMIT # ()'7 O~ - 0 I '6 ~ BillLDER ~ ~ v\..\. e. ~. PEST CONTROL CONTRACTOR \~~ ~\ ~ ~ LlUf PEST CONTROL LICENSE # -~ ç q d J:¿j We, the undersigned, hereby certify that we have pretreated the above-described construction for subterranean termites in accordance with the standards of the National Pest Control Association~ f) ,', ~ n \ fa \)" \ eX "~0 GAL~ 3~ 3 D Square feet of area treated: \d~1 Percentage of solution: ,,- ~ ~ rI~otal gallons used: - 1st Treatment ORe-treat Sla~ /' I:l' 1 st Treatment ORe-treat o Driveway o 1 st Treatment ORe-treat o Pools D· 1 st Treatment ORe-treat Other C~~, 1st Treatment ORe-treat o Perimeter for Final Inspection .. Date of tre 51;}?} D~7 íent: JOB ADDRESS q 4:) () W ',- ~~ cJ cl f', ..ÇA L ~ iT. Chemicals used: Time of Treatment: FBCI04.2.6 Certificate (1/ Protective Treatment/or prevention o/termites. A weather resistant jobsite posting board shall be provided to receive duplicate Treatment Certificates as each required protective treatment is completed, providing a copy for the person the permit is issued to and another copy for the building permit files. The Treatment Certificate shall provide the product used, identity of the applicator, time and date of the treatntent, site location, area treated, .chemical used, percent concentration and number of gallons used, to establish a verifiable record of protective treatment. If the soil chemical barrîer method for ternlite prevention is used, final exterior treatment shall be completed prior to final building approval. St Lucie County requires for the final inspection for CO, a Permanent Sticker to be placed on the electrical panel box cover, listing all the treatments and dates of applications. c}~1~: Signature~of exterminator NOTE: There 17IUst be a completed form for each required treatment or re-treatment and this fonn must be on the job site to be picked up by the inspector at time of each inspection or the scheduled inspection will fail alld a re-ilzspection fee charged. Re~'ised 6/13/02 dmg