HomeMy WebLinkAbout07030184
()~~T
DUNKELBERGER ENGINEERING & TESTING, INC.
SOIL DENSITY TEST REPORT
Project Name: Momingside Report Date: 06-19-07
St. Lucie County, Florida Lot No.: 208
Client Name: ~;~~e~:a~~: Boulevard, First~o~;CEIVED Permit No.: SLC-0703-0 184
Project No.: 06-1 0-2402
Boynton Beach, FL 33426 ;! ~ N 1 9 2007 Date Tested: 06- ] 9-07
..... OJ . Technician Initials: AMR
Atto: Mr. David Donvito ~.,; ~,~ t~')lic Works Sheet No.: 1 of 1
~- ,.' . ' ._ w _ ,--
Laboratory Proctor - ',_ . .1 . _' .I' L- Field Tests
Minimum
Probe Maximum Optimum Dry Cone Required Percent
Test Depth Dry Density Moisture Density Resistance1 Moisture Compaction Maximum Test
No. (in) (pet) (% ) (pet) (tst) (% ) (%) Density Result
1 12 120.0 10.0 120.5 - - - 8.2 95.0 100 Pass
2 12 120.0 10.0 120.7 - - - 8.7 95.0 101 Pass
3 ]2 120.0 10.0 120.0 - - - 8.5 95.0 100 Pass
4 ]2 ] 20.0 10.0 120.2 - - - 8.0 95.0 100 Pass
Type of Field Density Test:
Minimum Required Compaction Based on:
Ie· · d f1
() ASTM 0 1556 (X) ASTM D 2922
(X) AASHTO T-180 (ASTM D 1557)
d· b· d · h B· d K·l
() ASTM D 2937
() AASHTO T-99 (ASTM D 698)
M d 1 S 214 h d h ld
ompactlon percent estimate rom cone penetrometer rea Ing 0 talne WIt a ralnar - 1 man 0 e - an - e cone penetrometer.
Test Soil I
No. T,ype Elevation Test Location :L.ot 208,9430 Win d ri.ftCircle
1 2 0-12 Lot 208 at approximate center of house (slab subgrade)
2 2 0-12 Lot 208 at approximate center of garage (slab subgrade)
3 ]0 0-]2 Lot 208 at east side of house (footing subgrade)
4 10 0-12 Lot 208 at west side of house (footing subgrade)
Elevation Referenced to:
( ) NGVD
( ) MSL
(X) Other
Tests 1-2: Inches below top of slab subgrade
Tests 3-4: Inches below top of footing subgrade
SoilT .':
1 Structural Fill
2 Final Grading Fill
3 Mass Grading Fill
4 Utility Backfill- Sanitary
5 Utility Backfill - Water
6 Utility Backfill - Storm
7 Roadway Subgrade '
8 Stabilized Subgrade Craig E. Dunkelberger, P.~: '
9 Base Course FL Reai¡üat:iDIh"N~~t 1
10 Other: Footin Su b rade .J\J1t j. P 1liiI/,',
Note: The original of this report was signed and sealed by a registered engineer in accordance with Rule 61 G 15-18.0 II of the FJorida Administrative C e.
This report is submitted as the confidential property of our client and authorization for publication of statements, ~onclusions or extracts from or regarding
this report is reserved pending our written approval. The above-referenced testing was performed at the locations and depth interval described therein on
the associated report date. No other warranties with regard to subsurface exploration, recommendations or design are expressed by this finn.
cc: Centex Homes, David Donvito...(I)
Centex Homes, Eric Otto (site trailer)...(2)
St. Lucie County, Building Inspections...(I)
607NWCönl'ß)odityCove,iPørtSt.Lucie,.Florida34986ePhöne: (772) 343-9787 e Fax: (772}343-9404
State ofFl()rida Board of ProfessionaL Engineers · Authorization No · · 6870
8t Lucie County Inspections
2300 Virginia Avenue
Ft Pierce, FL 34982
(772) 462-2172
I. CERTIFICATE OF TERMITE TREATMENT
CONSTRUCTION SOIL TREATMENT
PERMIT # ()'7 O~ - 0 I '6 ~
BillLDER ~ ~ v\..\. e. ~.
PEST CONTROL CONTRACTOR \~~ ~\ ~ ~ LlUf
PEST CONTROL LICENSE # -~ ç q d J:¿j
We, the undersigned, hereby certify that we have pretreated the above-described construction for
subterranean termites in accordance with the standards of the National Pest Control Association~
f) ,', ~ n
\ fa \)" \ eX
"~0 GAL~
3~ 3 D
Square feet of area treated:
\d~1
Percentage of solution:
,,-
~ ~
rI~otal gallons used:
- 1st Treatment
ORe-treat
Sla~ /'
I:l' 1 st Treatment
ORe-treat
o Driveway
o 1 st Treatment
ORe-treat
o Pools
D· 1 st Treatment
ORe-treat
Other C~~,
1st Treatment
ORe-treat
o Perimeter for Final Inspection
..
Date of tre
51;}?} D~7
íent:
JOB ADDRESS q 4:) () W ',- ~~ cJ cl f', ..ÇA L ~ iT.
Chemicals used:
Time of Treatment:
FBCI04.2.6 Certificate (1/ Protective Treatment/or prevention o/termites.
A weather resistant jobsite posting board shall be provided to receive
duplicate Treatment Certificates as each required protective treatment is
completed, providing a copy for the person the permit is issued to and
another copy for the building permit files. The Treatment Certificate shall
provide the product used, identity of the applicator, time and date of the
treatntent, site location, area treated, .chemical used, percent concentration
and number of gallons used, to establish a verifiable record of protective
treatment. If the soil chemical barrîer method for ternlite prevention is used,
final exterior treatment shall be completed prior to final building approval.
St Lucie County requires for the final inspection for CO, a Permanent
Sticker to be placed on the electrical panel box cover, listing all the
treatments and dates of applications.
c}~1~:
Signature~of exterminator
NOTE:
There 17IUst be a completed form for each required treatment or re-treatment and this fonn must be on
the job site to be picked up by the inspector at time of each inspection or the scheduled inspection will
fail alld a re-ilzspection fee charged.
Re~'ised 6/13/02 dmg