Loading...
HomeMy WebLinkAboutdoc07358820200323142512All APPLICABLEINFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: 3 (�,)iPermit Number: Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential x PERMIT TYPE: Metal Re-Roof PROPOSED IMPROVEMENT LOCATION: Address: 4005 S Indian River Dr Property Tax ID #: 2435-111-0003-000-4 Lot No. Site Plan Name: Project Name: Malone Re-Roof Block No. DETAILED DESCRIPTION OF WORK:_ ASTM, 24 ga. Metal Re-Roof CONSTRUCTION INFORMATION: Additional work to be performed under this permit— check all that apply: _Mechanical _ Gas Tank _ Gas Piping _ Shutters _ Windows/Doors Electric _ Plumbing _ Sprinklers _ Generator _ Roof 2/12 Pitch Total Sq. Ft of Construction: Sq. Ft. of First Floor: Cost of Construction: $ 24,499.86 Utilities: _ Sewer _ Septic Building Height: OWNERAESSEE: CONTRACTOR: NameJames Malone Name:Jesus Vasquez, Jr. ' Address: 4005 S Indian River Dr Company: All American Roofing & Coating of FL City: Fort Pierce State: _ 34982 � Zip Code: Fax: Phone No. 772-464-9126 I E-Mail:lamesmalone@hotmail.com Fill in fee simple Title Holder on next page ( if different from the Owner listed above) Address: 340 SE Seville St. Stuart FL City: State: Zip Code: 34994 Fax: 772-781-4408 Phone No 772-781-4410 E-Mail office@allamericanroofer.com State or County LicenseCCC1329384 If value of construction is $2500 or more, a RECORDED Notice of Commencement is required. If value of HVAC is $7,500 or more, a RECORDED Notice of Commencement is required. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Mus ,W sigipecWy owner/Agent and applicant: /(Signature of cont r tor) 1,11 State of Florid , County of l 1A if1 Affirmed to and subscribed before me this _ -5 20IIr , by U \[ Mat nally known to me or who has prodliced C'�9p,��' °9i ntification. QV\y1 G 3: Pot Signature: S�0 M g33KZ -31 c rT t (print name)�".�, Y�i1,j-�,{/ C l jhK f ) anm a v. C, ai+ 0 � ^ O Z w truction documents must accompany this application. The Florida energy code submitted becomes an integral part of this iv p N ti. _ "2 g 5VE nd must pass final inspection. "Notice: In addition to the requirements of this permit, there may be additional restrictions i0 able to this property that may be found in the public record of this county, and there may be additional permits required PP P P tY Y P h, Y P q other governmental entities such as waste management district, state agencies, or federal agencies. "SIGNATURE OF THE APPLICANT MUST BE NOTARIZED. If owner builder, applicant must sign in person. BUILDING PERMIT includes: Building, Electrical, Plumbing, Mechanical, and Sewer only. All other trades require separate applications. Asbestos compliance: It is the owner's or operator's responsibility to comply with section 469.003, Florida Statutes, and to notify the Department of Environmental Protection of his or her intentions to remove asbestos, when applicable, in accordance with state and federal law. FEE SIMPLE TITLEHOLDER, BONDING COMPANY AND MORTGAGE LENDER INFORMATION IS REQUIRED WHEN THE AGGREGATE VALUE (TOTAL COST OF ALL IMPROVEMENTS AND NOT JUST WORK AUTHORIZED BY THE INDIVIDUAL PERMIT) IS $2500 OR MORE (EXCEPT HVAC REPAIR/REPLACEMENT< $7500). PLEASE ADDRESS ALL ITEMS. Fee Simple Titleholder's Name (if other than owner): Address' City: Mortgage Lender's Name: Address: City: ❑Same as Owner State: Zip: ❑ Not Applicable State: Zip: Bonding Company ❑ Not Applicable Name: Address: City: State: Zip: OFFICE USE ONLY Is the property located in a Special Flood Hazard Area (floodplain) per the current Flood Insurance Rate Map (FIRM) ❑ Yes ❑ No Flood Zone: Reviewed by: Determination: Permit Fee State Surcharge S Subcontractor S Other Other Flood Review Fee Total Amount Due at Issuance $ Remarks Plan Review Fee Routing Fee Other Active Code Violation O Yes ❑ No Case Case Type Reviewed by Date Final Check Date Page 2 of 2 gnature of Owner or Agent (including contractor)) ai•No�•. �� :; State of Florida County of .w ^ Affirmed to and subscribed beforemethis �/ + 20W, by on o „ known has duced 30 personally to me or who pr p 3 . n as identification. o g c ..a 2 r Notary Signature: a n; a X c 2 c R"°,0 — a ,,pQ'��p ,�,�p�� Notary ),fl.�lilt�Lll/V WV' Il�v w Nota (print name NN w 2 a Z w truction documents must accompany this application. The Florida energy code submitted becomes an integral part of this iv p N ti. _ "2 g 5VE nd must pass final inspection. "Notice: In addition to the requirements of this permit, there may be additional restrictions i0 able to this property that may be found in the public record of this county, and there may be additional permits required PP P P tY Y P h, Y P q other governmental entities such as waste management district, state agencies, or federal agencies. "SIGNATURE OF THE APPLICANT MUST BE NOTARIZED. If owner builder, applicant must sign in person. BUILDING PERMIT includes: Building, Electrical, Plumbing, Mechanical, and Sewer only. All other trades require separate applications. Asbestos compliance: It is the owner's or operator's responsibility to comply with section 469.003, Florida Statutes, and to notify the Department of Environmental Protection of his or her intentions to remove asbestos, when applicable, in accordance with state and federal law. FEE SIMPLE TITLEHOLDER, BONDING COMPANY AND MORTGAGE LENDER INFORMATION IS REQUIRED WHEN THE AGGREGATE VALUE (TOTAL COST OF ALL IMPROVEMENTS AND NOT JUST WORK AUTHORIZED BY THE INDIVIDUAL PERMIT) IS $2500 OR MORE (EXCEPT HVAC REPAIR/REPLACEMENT< $7500). PLEASE ADDRESS ALL ITEMS. Fee Simple Titleholder's Name (if other than owner): Address' City: Mortgage Lender's Name: Address: City: ❑Same as Owner State: Zip: ❑ Not Applicable State: Zip: Bonding Company ❑ Not Applicable Name: Address: City: State: Zip: OFFICE USE ONLY Is the property located in a Special Flood Hazard Area (floodplain) per the current Flood Insurance Rate Map (FIRM) ❑ Yes ❑ No Flood Zone: Reviewed by: Determination: Permit Fee State Surcharge S Subcontractor S Other Other Flood Review Fee Total Amount Due at Issuance $ Remarks Plan Review Fee Routing Fee Other Active Code Violation O Yes ❑ No Case Case Type Reviewed by Date Final Check Date Page 2 of 2 3%23/2020 33619_37166_1.jpg(800x800) https://www.paslc.org/imageSketches/sketch/33/33619_37166_1.jpg 1 i 1 A.111 Aimerican Roofing & Copfh g of Florida. ir_, All American Roofing and Coating of Florida. Inc. 340 SE Seville St. Stuart, FL 34994 (772) 781-4410 Adam McCalip (772)204-5503 adam.gallamericanroofer.com Licensed #CCC1329384 & Insured Contact: James Malone 4005 S Indian River Dr i Fort Pierce, FL 34982 (772)464-9126 jamesemajone@hotmaii.com Estimate No: 1148 Estimate Date: 212012020 rnce valla nor 10 Clays upon teceiPt U1 P1 vpvadl. Description All ,American Roofing will remove and dispose of existing Shingle roof down to plywood sheathing on main house and building in rear of house. AAR will inspect existing plywood sheathing and re -nail according to code. AAR will replace up to five (5) sheets 518" CDX plywood if needed, No Charge. AAR will install an ASTM self -adhered modified underlayment direct to plywood deck. AAR will install 24ca. Galvalume accessory metals. AAR will install new plumbing flashings at existing locations. AAR will install 3 new 10"gooseneck vents on main house and 3 new 10" gooseneck vents on building in rear of home. AAR will install a 24ga. 5-V Crimp Galvalume Metal Roofing System, fastened to code using 20yr Wood Zac Screws on main house and building in rear of home. AAR will procure permit and remove all roofing debris upon completion. AAR will provide a 10 -year Workmanship Warranty and any applicable Manufacturers' Warranties upon final payment. Labor and Materials Notes: Sub Total: 524,499.86 Anv Work done beyond the scope of this contract will be invoiced additionally and Total: $24,499.86 separately. 2) No verbal promises made by any representative of this company are binding unless contained in the Agreement. 3) Please note that price listed above is a "cash" price. If an alternative payment method is selected, additional fees and/or charges of 3.51 will apply. Please discuss payment methods at time of signing. TERMS This Proposal becomes a Contract upon, signing, Service will begin when the signed Contract and Notice of Commencement and a 30% deposit are received. Progress. 60% of the contract price is due. Upon completion of job the remaining 30% of the contract once is due immediately. If legal action is required to obtain final payment. customer will also be responsible :for payment of all legal fees incurred by Ali American Roofing and Coatino of Florida. Ali American Roofing will not be responsible for gutters or roof mounted olblec's such as Solar Panels. JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT - SAINT LUCIE COUNTY FILE # 4682206 OR BOOK 4390 PAGE 2243, Recorded 03/03/2020 12:29:26 PM C,I NOTICE OF COMMENCEMENT Permit No. _^ Tax Folio No.L 135—W OM --t,, I State of Florida County of St. Lucie Fz The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Fiorda Statutes, w_m) the following information is provided in this Notice of Commencement - 4p, + e rigt n J Pr`p6,6: t w �rc!K�ss i aivtai�l�abl l n t (� a� t� (%� WD `J U 11 j `1 l V ( W J General description of improvement: TLC._—YitJ� Owner info tion or Lessee'nf mats n if the Lessee contracted for the improvement: Name Address Q r Interest in property: a Name and address of fee simple titleholder (if different from Owner listed above): Contractor's Name:}'{'#�,y{�� �Qn�i 11i 1Wl}� /�' [ J)CktiW OF�L Contractor Address: 0 Phone Number: -1-77--779 Surety (if applicable, a copy of the payment bond is attached): Amount of bond: 5 Name and address: Phone number: Lender Name: Lender's addre Number: Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(i)(a)7., Florida Statutes: Name: Phone Number: in addition to himself or herself, Owner designates of Lienor's Notice as provided in Section 713.13(i)(b), Florida Statutes. Phone number of person or entity designated by owner: to receive a Copy of the Expiration date of notice of commencement- (the expiration date may not be before the completion of constructlor and final payment to I- contractor, but will be 1 year from the date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury, i declare that i have read the foregoing notice of commencement and that the facts stated therein are true to the best of my'Anowiedee and belief. ISlgnature of Owner or Lessee, or Owner's or Lessee's Authorized Officer/Director/Partner/Manager _/ .t r"O� {Signatory's Tit;e/Office) The foregoing instrument was acknowledged before me this t day of�_ 2010 «►* ��'.. JENNIFER LEE COUTINHO Notary Public - State or Florida Commission C GG 362000 Aly Comm. Expires Aug 4, 2023 Bonded through National Notary Assn. BV�IAAftVt1 t<lt t}�%— as mm for '?: `t V LARA ""^'..`.` — Na(ne f P son Type of authority (e.g.officer,trustee) earty on beh If of whom instrument was executed Personally known X or produced Idertification^ { nature of Notary Public - State Florida) TT �IC � {. int, Type, or Scamp Commissioned t'Ll t�(t�d Name of Notary Public} Type of Identification produced IUEREBYCEATu)nun,usooC INIE:T1s.ATRUE.ANDCORRECrcortOrANOFFICIALRECORDOR Digitally signed by The Honorable Joseph E. Smith DOfI IFNTAUTIIORITEDBI"1_tN'TOBFRFCORDFDORPIXTANDACTUALINRECORDEDORFILEDI, Date- 2020.03.03 12:31-15 05:00 THE OFFICE OF THE ST LUCIE COUNTY CLERK OF THE CIRCUIT COURT. Reason: Electronically Certified THIS DOCU E T ALAS HAVE REDACTIONS AS REQL IRED BY L.AVi'. Copy t ISiI HIT PN.'SrLUCIECLERIi.COM1LJERViC E.VE.CEAT'Itl'.OFFtC1.AL-RECORDS TO V'.A LIDAI E THIS DOCUM NU LOCation: 201 South Indian River Dr, Fort Pierce, FL 3` 1-50 3'23/2020 Florida Building Code Online BCIS Home Loa In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search db�` 1Product Approval pr % USER: Public User Product Approval Menu > Product or Application Search > Application List Search Criteria Refine Search Code Version 2017 FL# 21580.2 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model, Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL Search Results - Applications FL# Type Manufacturer Validated By. Status FL21580- Revision Florida Metal Products Inc. Michael John Approved R1 FL#: FL21580.2 Riemer, P.E. History Model: 2 - FLAMCO "Gooseneck Roof Vent" (561) 414-7557 Description: Gooseneck style roof vents for sloped shingle or the roofs fabricated from 26 gauge, G-40 primed, galvanized steel Category: Roofing Subcategory: Roofing Accessories that are an Integral Part of the Roofing System Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the commission if necessary. Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . ProducctApproval Accepts: 7-7 (A—All eireu: -- Credi' Card Safe https://www.floridabuilding,org/pr/pr_app_lst.aspx iii SpPctalty Structural EnginPPrinq UTO Manufacturer: Florida Metal Products, Inc, 6940 Stuart Avenue Jacksonville, FL 32254 for Florida Product Approval FL 21580.1 R1 CBUCK, Inc. Certificote of Authorization #8064 Florida Building Code 6th Edition (2017) Method: 2 - B Category: Sub - Category: Product Name: Product Description: Attached To: Prepared by: James L. Buckner, P.E., SECB Florida Professional Engineer # 31242 Florida Evaluation ANE ID: 1916 Project Manager: Diana Galloway Report No. Report No. 17-185- ORV-ER (Revises 16-143-ORV-ER, FL 21580.1) Date: 9/18/17 Contents: Roofing Roofing Accessories that are an Integral Part of the Roofing System "Off -Ridge Vent" Roof Vent Wood Deck Facsimile of digital copy signed by James L. Buckner, P.E. Electronically signed and sealed documents shall comply with the provisions of FAC Rule 61G15-23 �� �� ,.•' LtOENgF'•., F,p '� * ' No 31242 tum SOT •. STATE OF ; _4/1� i '•.FLORIDP.•' G\� rrt/tlll4l\1�` Evaluation Report Pages 1— 9 2017.10.19 20:13:36 -04'00' CBUCK, Inc. dba CBUCK Engineering Phone: (561) 491-9927 • Email: cbuck@cbuckinc.net - Website: www.cbuckinc.net Business: 1374 Community Dr., Jupiter, FL 33458 • Corp/Mailing: 2637 E. Atlantic Blvd, #34069, Pompano Beach, FL 33062 Specialty Structural Engineerinq 1.0 Manufacturer: Florida Metal Products, Inc. dba FLAMCO 6940 Stuart Avenue Jacksonville, Florida 32254 (800) 634-8400 http://flamco.com 2.0 Manufacturing Plant: Jacksonville, Florida 3.0 Product: 3.1 Product Name: "Off -Ridge Vent" 3.2 Product Description: Roof Vent 4.0 Evaluation Scope: 4.1 Compliance with the following Florida Building Code 6th Edition (2017) 4.2 Evaluation Method: FL #: FL 21580.1 R1 Date: 9/18/17 Report No.: 17-185-ORV-ER Page 2 of 5 CBUCK, Inc. Certificate of Authorization #8064 Florida Product Approval Rule 61G20-3.005 (2) (b) 4.3 Evaluation Classification: Category: Roofing Sub Category: Roofing Accessories that are an Integral part of the Roofing System 4.4 Properties Evaluated Structural (Wind Resistance) Properties 4.5 Limits of Evaluation: This product assembly evaluation is limited to compliance with section 4.1 to section 4.4 of this report. 5.0 Evaluated Uses: FLAMCO "Off -Ridge Vent" is used as a roof ventilator. 6.0 Product Assembly Description: 6.1 General: The FLAMCO "Off -Ridge Vents" are low profile, off -ridge roof vent for pitched roofs fabricated from 26 gauge, G-90 primed, galvanized steel with a galvanized steel mesh covering mechanically attached to Plywood Deck. 7.0 General Assembly as Evaluated: Refer to section 15.0 of this report for product assembly components/materials & standards. 8.0 Support System: (Design of support system is outside the scope of this evaluation.) 8.1 Type: Wood Deck 8.2 Description: 15/32" (min.) or greater plywood, or Wood plank deck (based on minimum density/specific gravity of 0.42) 9.0 Slope: Minimum slope shall be 2:12. (and in compliance with FBC Chapter 15 based on the type of roof covering, applicable code sections and in accordance with manufacturer's recommendations.) FL #: FL 21580.1 R1 Date: 9/18/17 Report No.: 17-185-ORV-ER Page 3 of 5 Speciaitj Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 10.0 Performance: 10.1 Wind Resistance: Table A Allowable Loads Design Uplift Pressure -46 PSF Notes: 1. Allowable design pressure(s) for allowable stress design (ASD) with a margin of safety of 2 to 1. 11.0 Performance Standard: The following test protocols were performed to demonstrate compliance with the intent of the code: 11.1 ASTM E330-02 — Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls, and Doors and by Uniform Static Air Pressure Difference 12.0 Code Compliance: 12.1 The product assembly described herein has demonstrated compliance with the Florida Building Code 6th Edition (2017) Section 1708.2. 13.0 Limitations and Conditions of Use: 13.1 Design of support system is outside the scope of this report. Support shall be structural framing members complying with the code and shall be designed by others. 13.2 Scope of "Limitations and Conditions of Use" for this evaluation: This evaluation report for "State Approval" contains technical documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under "State Approval". 13.3 Option for application outside "Limitations and Conditions of Use" Rule 61G20 -3.005(1)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. 13.4 This report is a building code product evaluation per FLPE rule (FAC) 61G15-36 to comply with Florida product approval rule (FAC) 61G20-3. This evaluation report is part of the Florida Building Commission approval for the listed code related criteria. This report by James Buckner, P.E. and CBUCK Engineering is not a design certification of code compliance construction submittal documentation, per FBC section 107, for any individual structure, site specific or permit design. 13.5 Structural loads shall comply with the design provisions of the FBC 6th Edition (2017), Chapter 16, Section 1609. 13.6 All metal components and fasteners shall be corrosion resistant in accordance with FBC, including but limited to Sections 1504.3.2, 1506.6 and 1507.4.4. 13.7 Refer to applicable building code section for ventilation requirements. 13.8 Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. 13.9 This report does not evaluate the use of this product assembly as described in this report for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties) 14.0 Quality Assurance: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc., (FBC Organization #QUA ID:1824). 15.0 System/Components 15.1 "Off Ridge Vent" 15.1.1 Material: Steel 15.1.2 Thickness: 26 gauge (min.) 15.1.3 Yield Strength: 40 ksi min. 15.1.4 Corrosion Resistance: In compliance with FBC Section 1507.4.3: ASTM A792 coated, or ASTM A653 G90 galvanized steel 15.1.5 Overall Product Dimensions (± %" nominal): 15.1.5.1 Length(s): 2', 4', 6' and 8' (max.) 15.1.5.2 Width: 23-1/2" (max.) 15.1.5.3 Height: 4-1/2" and 8-1/2" (max.) 15.2 Fastener: 15.2.1 Base Fastener: Attaches Roof Vent to Deck 15.2.1.1 Type: Smooth or Ring Shank Roofing Nails 15.2.1.2 Size: 11 gauge x 2" (Long) 15.2.1.3 Corrosion Resistance: Per FBC Section 1506.5 15.2.1.4 Standard: Per ASTM F 1667 15.3 Roof Adhesive: 15.3.1 Type: Standard Heavy bodied Flashing Cement 15.3.2 Description: Asbestos -free asphalt based roof cement 15.3.3 Application Size: 1/4" thick (min.) 15.3.4 Standard: Per ASTM D 4586 Type I 16.0 Installation Method: (Refer to installation method at the end of this evaluation report.) Prepare deck opening by trimming any shingles or tiles & existing nails that may interfere with ridge vent installation. Apply roof cement to the underside, back and side flanges of the ridge vent. Cement should be a 1/4" thick and extend 2" onto roof underlayment. (install cement in compliance with manufacturer's installation guidelines.) Position vent base flange beneath loosened shingles and align with deck opening. Attach the unit side flanges to deck with fasteners per Section 15.2.1 spaced 4" o.c. and 1" from each end. Apply Roofing Cement to exposed fastener heads. Minimum fastener penetration thru bottom of support, 3/16". The FLAMCO "Off -Ridge Vent" shall be installed in compliance with the installation method listed in this report and applicable code sections of FBC 6th Edition (2017). The installation method described herein is in accordance with the scope of this evaluation report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. 17.0 Evaluation Reference Data: 17.1 ASTM E330-02 Uniform Static Air Pressure Difference Test By Fenestration Testing Laboratory, Inc. (FTL) (FBC Organization #TST ID: 1657) Project #16-6647, Lab #9124, Dated: 11/09/16 17.2 Quality Assurance By Keystone Certifications, Inc. (FBC Organization #: QUA 1824) Licensee #440 17.3 Engineering Analysis By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization # ANE 1916) 17.4 Certification of independence By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization # ANE 1916) FL #: FL 21580.1 R1 Date: 9/18%17 Report No.: 17-185-ORV ER Page 5 of 5 SpL=cialtq Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 Installation Method FLAMCO "Off -Ridge Vent" Roof Vent "Off -Ridge Vent" (for Tile Roofs) Isometric View • :•- "Off -Ridge Vent" (for Shingle Roofs) Isometric View 4' o.c. Typical, M3) irrum — Fastener is 11 Gauge Galvanized Rang Shank Roofing Nail Range Top Plan View (Typical Fastening Pattern) (Not to Scale) 3/23/2020 Florida Building Code Online BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us SCIS Site Map Links Search d%1_11? b p Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List Search Criteria Refir, i a Search Code Version 2017 FL# 17022 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model, Number or Name ALL Product Description ALL ADproved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL Search Results - Applications FL# Type Manufacturer Validated By Status FL 17022-R7 Revision Extreme Metal Fabricators, LLC Zachary R. Priest, P.E. Approved History Category: Roofing (813) 480-3421 Subcategory: Metal Roofing "Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission, if necessary. Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The Slate of Florida is an AA/EEO employee CoP_Yright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. `Pursuant to Section 455.275(1`,., Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a be, address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click he, . Product Approval Accepts: Cr --d: Card Safe https://www.floridabuilding,org/pr/pr_app_lst.aspx 11%1 2160 SW Poma Drive Palm City, FL 34990 Compliant with Florida Building Code 2017 (6th ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications Product: 5 V Crimp 0.032" Aluminum Roof Panel FBC Sec. 1507.4.2 Yield strength: 0.032" Aluminum Min.; Attached to min. 1S/32" plywood or Wood Deck w/min 0.42 specific gravity with screws. 21" Coverage (Max.) Rib Height 3/8" Corrosion Resistant Compliant: FBC Sec. 1507.4.3 Fastener 1: #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" min embedment into wood plank. (*or of sufficient length to meet requirements) Underlayment: To be compliant with FBC Sec. 1507.1.1 Slope: Shall be in compliance with FBC Sec. 1507. Install Details: Table A Allowable Loads METHOD 1 DESIGN PRESSURE* I -168.5 PSF ROW SPACING --- — --- - 10" O.C. -- --- — — ---- FASTENER SPACING (ALONG ROWS) 10.5" O.C. Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527 UL 580-06 & 1897-041 Test Report D5893.04-450-18 10/24/14 *EQUIVALENCY: UL 1897-042 is equivalent to test standard UL 1897-12. *DESIGN PRESSURE -MARGIN OF SAFETY 2:1 Certificate of Independence: Locke Bowden, P.E. does not have, not will acquire a financial interest in any company manufacturing or distributing products under this evaluation. '„1 1 } s ir1fr Locke Bowden, P.E. is not owned, operated, or controlled by aQ a 1/, Q ffaf��cturer, or distributing products under this report. a � SEMI 0 ST,_ z c f � � Limitations 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed. 2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing compliant w/FBC 2017 6th ed.,Chapter 22 for Steel,Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This reportdoes not imply warranty, installation, recommended product use outside of this report. FL17022.2 5V Crimp (0.032" Alum), 21" Wide Roof Panel -Details Fastener -#9 X 1-112" Minimum 5-V Crimp Roof Panel Hex Washer Head Wood Screws 11 Deck: -15/32" or greater Plywood, or - Wood plank 21" — 10.5" 3/8" I OPTIONAL STRIATIONS Panel Profile Nominal 10.5" o.c. I Nominal 10.5" o.c. Panel Overlap Isometric View Fastener #9 x 1-1/5" Min. Hex Washer Head Screw Spaced 10.5" o.c. across the Panel Deck: - 15/32" or greater Plywood, or - Wood plank 3.'23!2020 Florida Building Code Online BCIS Home Loa in User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search d bProduct Approval USER: Public User Product Approval Menu > Product or ADDlication Search > Application List Search Criteria Refine Search Code Version 2017 FL# 11602.1 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model, Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL Search Results - Applications FL# ;Type Manufacturer Validated By Status FL11602-R10 ; Revision Owens Corning Roofing and Asphalt, LLC John W. Knezevich, PE Approved History FL#: FL11602.1 (954) 772-6224 Model: Titanium Roof Underlayments Description: Synthetic sheet -type roof underlayments Category: Roofing s Subcategory: Underlayments *Approved by DBPR. Approvals by DBPR shall be reviewed aIno ratified by the POC and/or the Commission if necessary. Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455. F.S., please click here . Product Approval Accepts: Cr (iii,, Gard Safe https://www.floridabuilding.org/pr/pr_app_lst.aspx ill D Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY ENIMm 's• Owens Corning Roofing and Asphalt, LLC Evaluation Report 111980.11.08-Rll One Owens Corning Parkway FL11602-RlO Toledo, OH 43659 (740) 321-6345 Date of Issuance: 11/03/2008 Revision 11: 10/17/2019 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Titanium"" Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMC) ETC, LLC requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOIetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8 Prepared by: Robert J.M. Nieminen, P.E.;,,:;_ i The facsimile seal appearing was authorized by P.ober, _ ..�; Nieminen, P.E. on 10/17/2019. This does not serve as an Florida Registration No. 59166, Florida DCA ANE1983 electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. L02018 NEMC) ETC, LLC NEMO etc. ROOFING COMPONENT EVALUATION: a• Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Titanium— Roof Underlayments, as produced by Owens Corning Roofing and Asphalt, LLC, have demonstrated compliance with the intent of the following sections of the 6' Edition (2017) Florida Building Code through testing in accordance with applicable sections the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section Property Standard Year 1504.3.1 Wind Uplift UL 1897 2012 1507.1.1, R905.1.1 Exception Unrolling, Breaking Strength, Pliability ASTM D226 2009 1507.1.1, R905.1.1 Exception Tear Strength ASTM D1970 2015 1507.1.1, T1507.1.1, 1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 (04-12) 2012 TAS 110 Accelerated Weathering ASTM D4798 2011 TAS 110 Pull-through resistance TAS 117(B) 1995 Entity Examination Reference Date ERD (TST6049) Physical Properties 115010.04.09 04/29/2009 ERD (TST6049) Physical Properties 115010.05.10 05/14/2010 ERD (TST6049) Physical Properties 135520.06.11 06/15/2011 ERD (TST6049) ASTM D226 138010.08.11 08/11/2011 ERD (TST6049) Wind Uplift 135520.08.11-1 08/12/2011 ITS(TST1509) ASTM D226 311801000Q-003 04/26/2007 ITS(TST1509) ASTM D226 3130639COQ-002A 08/21/2007 ITS(TST1509) Physical Properties 3126617COQ-005 10/31/2007 ITS(TST1509) ASTM D226 101823107COQ-011 01/23/2015 ERD (TST6049) Physical Properties (NH) 4j-OC-19-SSUDL-01.A 06/14/2019 Owens Corning Product equivalency Declaration 06/18/2018 PRI (TST5878) ASTM D1970 OCF-341-02-01 09/20/2017 PRI (TST5878) ASTM D1970; Tear strength OCF-331-02-02 10/03/2017 PRI (TST5878) ASTM D1970; Tear strength OCF-332-02-02 10/03/2017 PRI (TST5878) ASTM D1970; Tear strength OCF-334-02-02 10/03/2017 PRI (TST5878) FRSA/TRI April 2012 (04-12), partial OCF-343-02-01 11/09/2017 PRI (TST5878) ASTM D4798 OCF-341-02-01 11/27/2017 PRI (TST5878) TAS 117(B); Pull-through OCF-422-02-02 04/03/2018 PRI (TST5878) FRSA/TRI April 2012 (04-12), partial OCF-425-02-01 08/13/2018 PRI (TST5878) ASTM D226/ASTM D4798 OCF-331-02-01 R1 05/07/2019 PRI (TST5878) ASTM D226/ASTM D4798 OCF-332-02-01 RI 05/07/2019 PRI (TST5878) ASTM D226/ASTM D4798 OCF-334-02-01 R1 05/07/2019 PRI (TST5878) UL1897 1378TO02 07/10/2019 PRI (TST5878) Tensile adhesion OCF-507-02-01 08/13/2019 ITS (QUA1673) Quality Control ITS Listings Current ITS (QUA1673) Quality Control Service Confirmation 09/30/2017 MEMO ETC, LLC Evaluation Report 111980.11.08-Ril Certificate of Authorization #32455 6r" EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-R20 Titanium Roof Underlayments Revision 11: 10/17/2019 Page 2 of 8 Product Specification Plant(s) 4.1 Titanium'" PSU-30 ASTM D1970 Dubai, UAE & and FRSA/TRI Brentwood, NH April 2012 4.2 Titanium'" UDL-25 FBC 1507.1.1 Qingdao, China & R905.1.1 (Exception) 4.3 Titanium'" UDL-30 FBC 1507.1.1 Mission, BC, & R905.1.1 Canada & (Exception) Qingdao, China 4.4 Titanium'" UDL-50 FBC 1507.1.1 Mission, BC, & R905.1.1 Canada & (Exception) Qingdao, China Description unreinforced polymer modified bitumen material adhered to the underside of a polymer -coated, synthetic woven sheet. The underside is backed with a release film. Unit weight 24 lbs/square synthetic sheet -type underlayment comprised of a woven core coated on one side with a polymer coating. Unit weight 2.5 lbs./square synthetic sheet -type underlayment comprised of a woven core coated on both sides with a polymer coating. Unit weight 4.0 lbs./square synthetic sheet -type underlayment comprised of a woven core coated on both sides with a polymer coating. Unit weight 4.7 lbs./square 5.1 This is a building code evaluation. Neither MEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Titanium'" Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS Asphalt Wood Shakes Underlayment Shingles Nail -On Tile Foam -On Tile Metal & Shingles Slate Yes Titanium PSU-30 Yes Yes Yes Yes Yes (See 5.5.1) Titanium UDL-25 Yes No No Yes Yes Yes Yes Yes Titanium UDL-30 Yes (Base Sheet to 2 -ply (Base Sheet in 2 -ply Yes Yes Yes system) system) Titanium UDL-50 Yes No No Yes Yes Yes NEMO ETC, LLC Evaluation Report 111980.11.08-Rll Certificate of Authorization»32455 6" EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-R10 Titanium Roof Underlayments Revision 11: 10/17/2019 Page 3 of 8 NNEMOletc. 5.5.1 "Foam-On Tile" is limited to use of following Approved the adhesives / underlayment combinations. TABLE lA: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS' Underlayment Adhesive Florida Product Approval DUPONT Tile Bond"" FL22525 Titanium PSU-30 ICP Adhesives Polyset° AH-160 FL6332 ICP Adhesives Polysetw RTA-1 FL6276 5.6 Allowable Substrates (for self-adhering): TABLE 2: SUBSTRATE OPTIONS Underlayment Primer Substrates Titanium PSU-30 (Optional) ASTM D41 plywood None ASTM D226 felt ASTM D41 Titanium UDL-30 None Titanium UDL-30 (inverted) 5.6.1 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on the systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on the applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads. #1 Maximum Design Pressure = -45 psf: Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) ASTM D41 Underlayment: One or two plies, Titanium PSU-30, self -adhered and back -nailed max. 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1 -5/8 -inch diameter tin caps in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. #2 Maximum Design Pressure = -30 psf*: Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (inverted) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16 -inch with min. 32 ga., 1-5/8" diameter tin caps Spacing: 6 -inch o.c. at 4 -inch wide side laps and 12 -inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required at all tin -caps. Underlayment: One or two plies, Titanium PSU 30, self -adhered and back -nailed max. 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1 -5/8 -inch diameter tin caps in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. ' Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance MEMO ETC, LLC Evaluation Report 111980.11.08-RSl Certificate of Authorization #32455 6Tk EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-R10 Titanium Roof Underlayments Revision 11: 10/17/2019 Page 4 of 8 #3 Maximum Design Pressure = -30 psf*: Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (printed side up) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16 -inch with min. 32 ga., 1-5/8" diameter tin caps. Spacing: 6 -inch D.C. at 4 -inch wide side laps and 12 -inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required over printed side of UDL-30. Underlayment: One or two plies, Titanium PSU 30, self -adhered and back -nailed max. 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1 -5/8 -inch diameter tin caps in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. #4 Maximum Design Pressure = -45 psf*: Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (inverted) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16 -inch with min. 32 ga., 1-5/8" diameter tin caps Spacing: 6 -inch D.C. at 4 -inch wide side laps and 8 -inch D.C. at three (3), equally spaced center rows. Primer: ASTM D41 primer required at all tin -caps. Underlayment: One or two plies, Titanium PSU 30, self -adhered and back -nailed 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1 -5/8 -inch diameter tin caps in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. #5 Maximum Design Pressure = -45 psf*: Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (printed side up) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16 -inch with min. 32 ga., 1-5/8" diameter tin caps. Spacing: 6 -inch o.c. at 4 -inch wide side laps and 8 -inch D.C. at three (3), equally spaced center rows. Primer: ASTM D41 primer required over printed side of UDL-30. Underlayment: One or two plies, Titanium PSU 30, self -adhered and back -nailed 6" D.C. with 12 ga. galvanized annular rink shank nails through 32 ga., 1 -5/8 -inch diameter tin caps in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. 5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: Titanium UDL-25, Titanium UDL-30, Titanium UDL-50 or Titanium PSU-30 shall not be left exposed for longer than 180 -days. NEMO ETC, LLC Evaluation Report 111980.11.08-Rll Certificate of Authorization #32455 6T' EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-R10 Titanium Roof Underlayments Revision 11: 10/17/2019 Page 5 of 8 5.8 Tile Slippage Limitations (per FRSA/TRI April 2012 (04-12)): When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 3: TILE SLIPPAGE UMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Titanium PSU-30 Flat Max. 10 -tile stack 5:12 Flat Max 5 -tile stack 6:12 Lugged Max. 10 -tile stack 4:12 Lugged Max. 5 -tile stack 5:12 Lugged Max. 10 -tile stack (5 over 5) i I 5:12 I I L__ OPPF7 Mechanical attachment of Titanium UDL-50 is limited to ring shank roofing nails with minimum 3/8 -inch diameter heads; ring shank roofing nails with minimum 1 -inch diameter plastic caps; screws and plates; or plastic cap staples. 6.3.2.1 Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 states: "...except metal cap nails small be required where the ultimate design wind speed, Vau,D equals or exceeds 150 mph." Owens Corning Roofing and Asphalt, LLC has furnished data to permit the use of 1 -inch diameter plastic cap nails in lieu of metal cap nails for these applications, when the Titanium— UDL-25, Titanium UDL-30 or Titanium UDL-50 underlayment is installed beneath mechanically fastened prepared roof covers referenced in FBC Table 1507.1.1 or R905.1.1. NE14+10 ETC, LLC Evaluation Report 111980.11.08-1111 Certificate of Authorization #32455 6r" EDITION (2017) FSC NON-HVHZ EVALUATION FL11602-P.10 Titanium Roof Underlayments Revision 11: 10/17/2019 Page 6 of 8 *NEMO I etc. 6.3.3 Slopes of 4:12 or greater: End (vertical) laps shall be minimum 6 -inches and side (horizontal) laps shall be minimum 4 -inches. End (vertical) laps shall be offset from course to course not less than 6 feet. Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the battens. 6.3.4 Slopes of 2:12 to less than 4:12: End (vertical) laps shall be minimum 12 -inches and side (horizontal) laps shall be minimum 25 -inches. End (vertical) laps shall be offset from course to course not less than 6 feet. Begin by fastening a 25 -inch wide strip along the eaves. Place a full -width sheet over the starter, completely overlapping the starter course. Continue upslope, maintaining minimum 25 -inch side (horizontal) laps, resulting in a double -layer application. Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. Secure end laps 4 -inch o.c. When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the battens. 6.4 Titanium'"° PSU-30: 6.4.1 Non -Tile Installations: Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed, and Owens Corning published requirements. TitaniumT" PSU-30 shall be back -nailed in accordance with Owens Corning published installation requirements. 6.4.2 Nail -On Tile Applications: Shall be installed in compliance with the requirements for Self -Adhered Membrane underlayment set forth in FRSA/TRI April 2012 (04-12), and Owens Corning published requirements. Titanium'" PSU-30 shall be back -nailed max. 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1 -5/8 -inch diameter tin caps in accordance with Owens Corning published installation requirements. Refer to Section 5.8 for tile staging limitations. 6.4.3 Foam -On Tile Applications: Shall be installed in compliance with the requirements for Self -Adhered Membrane underlayment set forth in FRSA/TRI April 2012 (04-12), and Owens Corning published requirements. Titanium"" PSU-30 shall be back -nailed max. 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1 -5/8 -inch diameter tin caps in accordance with Owens Corning published installation requirements. Refer to Table lA for allowable tile adhesives. Refer to Section 5.6.1 for wind uplift limitations. Refer to Section 5.8 for tile staging limitations. 6.5 Titanium 2 -Ply System: 6.5.1 The Titanium 2 -Ply System consists of a base layer of Titanium UDL-30 (top -surface primed or sheet inverted) mechanically attached to the wood roof deck followed by Titanium PSU-30, self -adhered. 6.5.2 Non -Tile Applications: Install Titanium UDL-30 (top surface primed or sheet inverted) in accordance with Section 6.3 followed by Titanium PSU-30 in accordance with Section 6.4. NEMO ETC, LLC Evaluation Report 111980.11.08-1171 Certificate of Authorization #3245S 6n+ EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-R10 Titanium Roof Underlayments Revision 11: 10/17/2019 Page 7 of 8 6.5.3 Nail -On Tile Applications: For nail -on tile installations, install Titanium UDL-30 (top surface primed or sheet inverted) in accordance with FRSA/TRI April 2012 (04-12), using Section 6.3 as a guide, and considering the wider sheet width relative to ASTM D226 felt. Then apply Titanium PSU-30 in accordance with Section 6.4. Refer to Section 5.8 for tile staging limitations. 6.5.4 Foam -On Tile Applications: For foam -on tile installations, install Titanium UDL-30 (top surface primed or sheet inverted) in accordance with Section 5.6.1 herein. Then apply Titanium PSU-30 in accordance with Section 6.4 Refer to Table 1A for allowable tile adhesives. Refer to Section 5.6.1 for wind uplift limitations. Refer to Section 5.8 for tile staging limitations. to Section 4 herein for product & production locations having met codified physical properties specifications. . jtlAl1TY55URAiVE gffil =Nam= A Intertek Testing Services NA Inc. — QUA1673; (604) 520-3321 - END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report 111980.11.08-Rll Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-R10 Titanium Roof Underlayments Revision 11: 10/17/2019 Page 8 of 8