Loading...
HomeMy WebLinkAboutSpec Transfer SwitchAutomatic Transfer Switches Description Service and non -Service rated Automatic Smart Transfer Switches 100 - 400 Amps, Single Phase C @ us LISTED �MMa *CUL only applies to non -service rated switches Generac Automatic Transfer Switches are designed for use with single phase generators that utilize an Evolution TM or Nexus TM Controller. The 100, 200, and 400 amp open transition switches are available in single phase in both service equipment rated and non -service equipment rated configurations. The 150 and 300 amp open transition switches are only available in a service rated equipment configuration. Standard Features Service rated (RXSW) Generac Automatic Transfer Switches are housed in an aluminum NEMA/UL Type 3R enclosure*, with electrostatically applied and baked powder paint. The Heavy Duty Generac Contactor is a UL recognized device, designed for years of service. The controller at the generator handles all the timing, sensing, exercising functions, and transfer commands. All switches are covered by a 5 year limited warranty. * Non -service rated (RXSC) switches are housed in a steel enclosure. DPM Technology Through the use of digital power technology (DPM), these switches have the capability to manage up to 4 individual HVAC (24 VAC controlled) loads with no additional hardware. When used in tandem with Smart Management Modules, up to 8 more loads can be managed as well, providing the most installation efficient power management options available. ISO 100 1: 2008 GENERAC® 100-400 Amps, Single Phase I All timing and sensing functions originate in the generator controller Automatic Smart Transfer Switches Utilityvoltage drop -out ................ ......... ......................................... ....................... .......... ............................................... .................... ........... .............. ....................... <65% Timer to generator start..................................................................................................10 second factory set, adjustable between 2-1500 seconds by a qualified dealer* Enginewarm up delay.................................................................................................................................................................................................................5 seconds Standbyvoltage sensor .................. ....................................... ............................................. ....... :...................... ... ............. ............... .................... ...........65% for 5 seconds Utilityvoltage pickup... ............. _ .............. _ ................................................................................................................ ................................. .................................. > 80% Re -transfer time delay.. .............. ......................................... ............... _ .......... ...................................... .............. ........ .............. ....... _ ............................... 15 seconds Enginecool -down timer............................................................................................................................................................................................................60 seconds Exerciser..............................................................................................................................................................5 or 12 minutes adjustable weekly/Bi-weekly/Monthly. The transfer switch can be operated manually without power applied. *When used in conjunction with units utilizing Evolution'" controls —Adjustable via the controller Model RXSC100A3 RXSW100A3 RXSW150A3 RXSC200A3 RXSW200A3 RXSW300A3 RXSC400A3 RXSW400A3 Amps 100 100 150 200 200 300 400 400 Voltage 120/240,10 120/240,10 120/240,10 120/240,10 120/240,10 120/240,10 120/240,10 120/240,10 Load Transition Type (Automatic) Open Transition Open Transition Service Rated Open Transition Service Rated Open Transition Open Transition Service Rated Open Transition Service Rated Open Transition Open Transition Service Rated Enclosure Type NEMA/UL 313 NEMA/UL 313 NEMA/UL 313 NEMA/UL 313 NEMA/UL 3R NEMA/UL 311 NEMA/UL 311 NEMA/UL 3R UL Rating UUCUL UL UL UUCUL UL UL UL/CUL UL Withstand Rating (Amps) 10,000 10,000 22,000 10,000 22,000 22,000 22,000 22,000 Lug Range 1/0 - #14 250 MCM - #6 600 MCM - #4 or 1/0 - 250 MCM Dimensions Model RXSC100A3 RXSW100A3 RXSW150A3 RXSC200A3 RXSW200A3 RXSW300A3 RXSC400A3 RXSW400A3 Height Hit 17.24/437.9 17.24/437.9 26.75/679.4 17.24/437.9 26.75/679.4 42.91/1089.9 31.25/793.8 42.91/1089.9 (in./mm) H2 20/508 20/508 30/762 20/508 30/762 48/1219.2 36/914.4 48/1219.2 Width W1 12.5/317.5 12.5/317.5 10.5/266.7 12.5/317.5 10.5/266.7 16.69/423.9 19.18/487.2 16.69/423.9 (in./mm) W2 14.6/370.8 14.6/370.8 13.5/342.9 14.6/370.8 13.5/342.9 21.82/554.2 24/609.6 21.82/554.2 Depth (in./mm) 7.09/180.1 7.09/180.1 6.3/160.1 7,09/180.1 6.3/160.1 10.06/255.5 10.06/255.5 10.06/255.5 Weight (Ibs./kilos) 20/9.07 22.5/10.21 39/17.69 20/9.07 39/17.69 140/63.5 133/60.33 140/63.5 b H2 H' I�DEPTH-1 L-- 112 --1 DEPTH GENERAC® General; Power Systems, Inc. - S45 W29290 HWY.. 59, Waukesha, WI 53189 - generac.com 02017 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 1000001 3459-A 04/24/17