Loading...
HomeMy WebLinkAboutEason Wattage worksheetWattage Worksheet 2100 Fairfax Road, Greensboro, NC 27407 Phone: 336-448-4000 / Toll Free: 1-888-372-3278 Name:William Eason Estimate Date: 02/19/2020 RSVP ID:113595 Address:1107 Driftwood Lane Prefer Phone:864-977-1049 Cell Phone: City State Zip:Fort Pierce FL 34982 Home Phone:864-977-1049 Cell Phone 2: Email:eason4549@att.net Work Phone:Fax: General Loads - Includes one circuit in each room/area listed SqFt / Qty Priority Primary or Secondary VA kW General Lighting - Whole House 1900 1 1 5700 5.700 Branch Circuit - Laundry Circuits 1 1 1 1500 1.500 Branch Circuit - Small Appliance Circuits 2 1 1 3000 3.000 Fixed Appliances - Clothes Dryer - Electric 1 1 1 5000 5.000 Fixed Appliances - Dishwasher 1 1 1 1500 1.500 Fixed Appliances - Disposal 1 1 1 1500 1.500 Fixed Appliances - Garage Door Opener 1 1 1 500 0.500 Fixed Appliances - Irrigation Pump for Sprinkler Systems 1 1 1 1750 1.750 Fixed Appliances - Microwave (not counter-top model)1 1 1 1500 1.500 Fixed Appliances - Pool Pump (1.5 - 2.0 HP)1 1 1 1500 1.500 Fixed Appliances - Range/Oven Combination 1 1 1 8000 8.000 Fixed Appliances - Water Heater 1 1 1 4500 4.500 Heat / A-C Load Wattage Priority Primary or Secondary VA kW Type: Heat Pump Area Served: Compressor and Fan 4830 1 2 4830 4.8 Supplemental Electric Heat 10000 1 2 6500 6.5 Total Calculated Load:Primary 20380 VA (84 Amp)Primary 20.4 kW Secondary 11330 VA Secondary 11.3 kW Electrical Utility Company:FPL Electrical Jurisdiction:Ft Pierce Gas Utility Company:Blossman Gas Jurisdiction:Ft Pierce