HomeMy WebLinkAbout07040445 (2) ()~~T DUNKELBERGER ENGINEERING & TESTING, INC. Project Name: SOIL DENSITY TEST REPORT Morningside St. Lucie County, Florida Boynton Beach, FL 33426 06-20-07 415 SLC 0704-0445 06-1 0-2402 06-20-07 AMR 1 of 1 Report Date: Lot No.: Permit No.: Project No.: Date Tested: Technician Initials: Sheet No.: Client Name: Attn: Mr. David Donvito . : ·~a,boratoryPr()ctor Field Tests Minimum Probe Maximum Optimum Dry Cone Required Percent Test Depth Dry Density Moisture Density Resistance1 Moisture Compaction Maximum Test No. (in) (pet) (% ) (pet) (tst) (% ) (%) Density Result 1 12 120.0 10.0 120.3 - - - 7.5 95.0 100 Pass 2 12 120.0 10.0 120.5 - - - 7.8 95.0 100 Pass 3 12 120.0 10.0 120.8 - - - 7.0 95.0 101 Pass 4 12 120.0 10.0 120.1 - - - 7.2 95.0 100 Pass Type of Field Density Test: Minimum Required Compaction Based on: Ie· · d fj () ASTM D 1556 (X) ASTM D 2922 (X) AASHTO T-180 (ASTM D 1557) d· b· d · h B· d K·j () ASTM D 2937 () AASHTO T-99 (ASTM D 698) M d 1 S 214 h d h ld ompactlon percent estImate rom cone penetrometer rea Ing Ö talne WIt a ralnar - 1 man 0 e - an - e cone penetrometer. Test:·' S'oll No. Type E:levatio:lI: 'fest..Location:: ..Lot· 415,··.136< Blue· Grotto Drive 1 2 0-12 Lot No. 415, approximate center of house (slab subgrade) 2 2 0-12 Lot No. 415, approximate center of garage (slab subgrade) 3 10 0-12 Lot No. 415, east side of house (footing subgrade) 4 10 0-12 Lot No. 415, west side of house (footing subgrade) Soil T Structural Fill Final Grading Fill Mass Grading Fill Utility Backfill - Sanitary Utility Backfill - Water Utility Backfill - Storm / Vj Roadway Subgrade é ~ ' V' . _ // Stabilized Subgrade CraIg E. D\lnkelberger, P. ./ l I 9 Base Course FL Registra.tion No. 49932 I 10 Other: Footin Sub rade ':?' Note: The original of this report was signed and sealed by a registered engineer in accordance with Rule 6IGI5-18.011 of the FloJUN:b'.i9a. è. This report is submitted as the confidential property of our client and authorization for publication of statements, conclusions or extracts from or egarding this report is reserved pending our written approval. The above-referenced testing was performed at the locations and depth interval described ther~ln on the associated report date. No other warranties with regard to subsurface exploration, recommendations or design are expre~sed by this firm. 60·7 NW·CommodityCove, Port St. Lucie, Florida34986-Phone: (772) 343-9787-Fax: (772) 343-9404 State of Florida Board of Professional Engineers Authorization No. 6870 Elevation Referenced to: Tests 1-2: Inches below top of slab subgrade. Tests 3-4: Inches below top of footing subgrade. ( ) NGVD ( ) MSL (X) Other 1 2 3 4 5 6 7 8 cc: Client... (1 ) Centex Homes, Eric Otto (site trailer)... (2) St. Lucie County, Building Inspections... (])