Loading...
HomeMy WebLinkAbout07040444 (2) D-l~ -Ó-tL\l( 8t Lucie County Inspections 2300 Virginia A venue Ft Pierce, FL 34982 ;~ , . Á'~~~ ..czOR\\)~ (772) 462-2172 '."(" Ρ" , . ~(¡1t ~"'I~ i. CERTIFICA TE OF TERMITE TREA Tl\.fE~/~ ':~.?<1; ì ~J CONSTRUCTION SOIL TREA TMENT ~"r. '.' "'\ ~(.r? ç. . .... ~ PERMIT # IJ I A JOB ADDRESS G':) ~ 'I If e q S' 0 / sif.t··'..~) a.s~ S<f-.. BUILDER C: Q,~ ·t~,¿ PEST CONTROL CONTRACTOR_t-\b IV\ ~ ~ <'~ p (> ~+ \D ~ ·Ç'e Y\ ~ Q ~ç C)";J ~'~ PEST CONTROL LICENSE # We, the undersigned, hereby certify that we have pretreated the above-described construction for subterranean termites in accordance with the standards of the National P t Control Association~ Square feet of area treated: ; 3 ì LJ' Chemicals used: ..> f þ ~.'.\, \' cA Percentage of solution: "'---- t) Total gallons used: . "/0 (~1 ,J : '-I D Date of treatment: ~{ I~f 0l Time of Treatment: o Footing o 1st Treatment ORe-treat o Slab o 18t Treatment ORe-treat o Driveway o 1 st Treatment ORe-treat o Pools o 1st Treatment ORe-treat o Other o 1 st Treatment ORe-treat o Perimeter for Final Inspection FBCI04.2.6 Certificate of Protective Treatment for prevention of termites. A weather resistant jobsite posting board shall be provided to receive duplicate Treatment Certificates as each required protective treatment is completed, providing a copy for the person the permit is issued to and another copy for the building permit fil!!s. The Treatment Certificate shall provide the product used, identity of the applicator, time and date of the treatment, site location, area treated, ,chemical used, percent concentration and number of gallons used, to establish a verifiable record of protective treatment. If the soil chemical barrier method for termite prevention is used, final exterior treatment shall be completed prior to final building approval. St Lucie County requires for the final inspection for CO, a Permanent Sticker to be placed on the electrical panel box covek~ listing all the treatments and dates of applications. Signature of exterminator NOTE: There nlust be a completed form for each required treatment or re-treatment and this fonn must be on tlte job site to be picked up by the inspector at time of each inspection or the scheduled inspection will fail and a re-illspection fee charged. Revised 6/13/02 dmg I)~~T DUNKELBERGER ENGINEERING & TESTING, INC. SOIL DENSITY TEST REPORT Project Name: Morningside Report Date: 06-19-07 St. Lucie County, Florida ," >'~'" RECEIVED Lot No.: 902 Client Name: Centex Homes ~, Permit No.: SLC-0704-0444 3301 Quantum Boulevard, ~loor JUN 1 9 2007 Project No.: 06-1 0-2402 .~ Boynton Beach, FL 33426 ¡:~~~ Date Tested: 06- ] 9-07 ~;~;~ Public Works Technician Initials: AMR Attn: Mr. David Donvito ,(I~1Ai.·r;..~ St. Lucie County, FL Sheet No.: ] of 1 :JDI" Laboratory Proctor Field Tests Minimum Probe Maximum Optimum Dry Cone Required Percent Test Depth Dry Density Moisture Density Resistance1 Moisture Compaction Maximum Test No. (in) (pct) (% ) (pct) (tst) (% ) (0Æ» ) Density Result 1 12 120.0 10.0 120.2 - - - 8.2 95.0 100 Pass 2 12 120.0 10.0 119.8 - - - 8.8 95.0 99.8 Pass 3 12 120.0 10.0 120.5 - - - 8.5 95.0 100 Pass 4 12 120.0 10.0 120.1 - - - 8.3 95.0 100 Pass Type of Field Density Test: Minimum Required Compaction Based on: Ie· · d f1 () ASTM 0 1556 (X) ASTM D 2922 (X) AASHTO T-180 (ASTM D 1557) dO b· d ·th BOd Kï () ASTM D 2937 () AASHTO T-99 (ASTM D 698) MdlS214h dhld ompactlon percent estImate rom cone penetrometer rea 109 0 talne WI a ralnar - I man o e - an - e cone penetrometer. Test S'oll No. Type Elevation Test Location: Lot 902, 9334 Treasure Coast Drive 1 2 0-12 Lot 902 at approximate center of house (slab subgrade) 2 2 0-12 Lot 902 at approximate center of garage (slab subgrade) 3 10 0-12 Lot 902 at east side of house (footing subgrade) 4 10 0-12 Lot 902 at west side of house (footing subgrade) Elevation Referenced to: ( ) NGVD ( ) MSL (X) Other Tests 1-2: Inches below top of slab subgrade Tests 3-4: Inches below top of footing subgrade Soil>:10: .. e Structural Fill Final Grading Fill Mass Grading Fill Utility Backfill - Sanitary Utility Backfill - Water ""ð-~, ' Utility Backfill - Storm /" /' (/' I ¿ ,,> . Roadway Subgrade .... ~~ ~ Stabilized Subgrade V . r~Craig E. Dunkelberger, P. Base Course FL Registration No. 499, ; '1 v 10 Other: Footin Sub rade ? . Note: The original of this report was signed and sealed by a registered engineer in accordance with Rule 61G15-18,OII of the FII>,. AflnOisGaft'C I, e, This report is submitted as the confidential property of our client and authorization for publication of statements, conclu~~r ~trMts ~~r 'garding this report is reserved pending our written approval. The above-referenced testing was perfonned at the locations and depth interval described therein on the associated report date, No other warranties with regard to subsurface exploration, recommendations or design are expressed by this finn, 1 2 3 4 5 6 7 8 9 cc: Centex Homes, David Donvito... (1) Centex Homes, Eric Otto (site trailer)...(2) St. Lucie County, Building Inspections... (1) 6.Ø7NWCornnïoditY'Gove,Potf ·St.)J...ûcië~Flc.)ridå..·i3498ôi"iiPbotle:, .'(772)343...9787,' , '...,.Fax:(772~ 343..9404 $tateofFloriâa.13()àrdof:Prof~ssiollålE1'lgil1eers·AuthQrizati()nNo..ô870