Loading...
HomeMy WebLinkAbout07040559 Rli:CEIVED JUN 0 8 2007 ¡ '. -.if Æ- j BY. __. . P.E. No. 65276 - Audit No. 0507-029661 3()48 ÎndustriaI33rdSt:;Ft.PlerÅ“,Fi34946 . Phone (772) 429-1000 . Fax (772) 465-5442 June 5, 2007 S1. Lucie Building Department 2300 Virginia Ave. Fort Pierce, FL 34982 This letter in regards to the following pennitted job for South Florida Aluminum Products, pennit #07040559. Project: 70-28 3621 Redtail Hawk Dr. Port S1. Lucie, FL 34952 After careful review and analysis of these jobs the following changes will be made: 1 ) In lieu of the "U" strap, top and bottom on the sidewall that has a 209 lb. uplift rating; we will allow the use of the Simpson 2.5 Hurricane Clip, top and bottom with 475lb uplift rating. 2) 3/8" wedge bolts on 32" centers, also meets the uplift rating. 3) We will allow a single 2"x 4" top plate for walls up to 16' in length. 4) After doing the calculations, we find that using (3) #14 xl" S.M.S. on each side of a 3" x 3" post (6 total) to the "U-Clip" or insert, meets or exceeds the uplift required. The future engineering sheet for South Florida Aluminum Products will have these details on them. Please call if you have any questions. U\ Mike Edgerly, P .E. Skyline Engineerin¡ 3048 Industrial 33~ 81. F1. Pierce, FL 34946 (772) 465-5441 ~,( jUN 0 6 1.0n1 (RECEIVÊ:î5l I' JUN 0 8 2.007 I d2~' I· / ~ I· .... . ..__, i ,BY.._~~_ P.E. No. 65276 - Audit No. 0507-029661 3048 Industrial 33rdSt. · Ft. Pierce, FL 34946 . Phone (772) 429-1000 . Fax (772) 465-5442 June 5, 2007 S1. Lucie Building Department 2300 Virginia Ave. Fort Pierce, FL 34982 This letter in regards to the following pennitted job for South Florida A1wninwn Products, permit #07040559. Project: 70-28 3621 Redtail Hawk Dr. Port S1. Lucie, FL 34952 After careful review and analysis of these jobs the following changes will be made: 1) In lieu of the "u" strap, top and bottom on the sidewall that has a 209 lb. uplift rating; we will allow the use of the Simpson 2.5 Hurricane Clip, top and bottom with 475lb uplift rating. 2) 3/8" wedge bolts on 32" centers, also meets the uplift rating. 3) We will allow a single 2"x 4" top plate for walls up to 16' in length. 4) After doing the calculations, we find that using (3) #14 xl" S.M.S. on each side of a 3" x 3" post (6 total) to the "U-Clip" or insert, meets or exceeds the uplift required. The future engineering sheet for South Florida A1wninwn Products will have these details on them. Please call if you have any questions. Thank You, ~ri Mike Edgerly, P .E. Skyline Engineerïn¡ 3048 Industrial 33r St. Ft. Pierce, FL 34946 (772) 465-5441 ~v JUN 0 6 20Q1