HomeMy WebLinkAbout07050170 (2)
()~~T
DUNKELBERGER ENGINEERING & TESTING, INC.
SOIL DENSITY TEST REPORT
Project Name:
Morningside
St. Lucie County, Florida ECEIVED
Centex Homes R
3301 Quantum Boulevard, First Floor JUN 1 9 2007
Boynton Beach, FL 33426
Report Date:
Lot No.:
Permit No.:
Project No.:
Date Tested:
Public Works "TécÌ1nician Initials:
ucie COlJnt~!, ¡=L '.- .,ù~ Sheet No.:
06-] 9-07
914
SLC-0705-0 1 70
06-1 0-2402
06-19-07
AMR
1 of 1
Client Name:
Attn:
Mr. David Donvito
Lab9'ratoryproctor Field Tests
Minimum
Probe Maximum Optimum Dry Cone Required Percent
Test Depth Dry Density Moisture Density Resistance1 Moisture Compaction Maximum Test
No. (in) (pet) (%) (pet) ( tsJ) (o~) (%) Density Result
] 12 120.0 10.0 120. I - - - 8.2 95.0 100 Pass
2 ]2 120.0 ]0.0 ] 20.8 - - - 8.7 95.0 101 Pass
3 12 120.0 10.0 120.3 - - - 8.5 ·95.0 100 Pass
4 12 120.0 10.0 120.5 - - - 8.0 95.0 100 Pass
Type ofField Density Test:
Minimum Required Compaction Based on:
1C· · d f]
() ASTM 0 1556 (X) ASTM D 2922
(X) AASHTO T-180 (ASTM D 1557)
d· b· d · h B· d K·I
() ASTM D 2937
() AASHTO T-99 (ASTM D 698)
M d ] S 2] 4 h d h ld
ompactlon percent estImate rom cone penetrometer rea Ing 0 talne WIt a ralnar - 1 man 0 e - an - e cone penetrometer.
Test Soil
No. Type Elevation ~¢stJi,()cati()Il:Lot..9J.4,·9318Breakers R()w
] 2 0-12 Lot 914 at approximate center of house (slab subgrade)
2 2 0-12 Lot 914 at approximate center of garage (slab subgrade)
3 10 0-12 Lot 914 at east side of house (footing subgrade)
4 10 0-12 Lot 914 at west side of house (footing subgrade)
Elevation Referenced to:
( ) NGVD
( ) MSL
(X) Other
SoilT e
1 Structural Fill
2 Final Grading Fill
3 Mass Grading Fill
4 Utility Backfill - Sanitary ,
5 Utility Backfill - Water .... ~/~.~" ,'/ _ .
6 Utility Backfill - Storm ,..//"" (~ - J
7 Roadway Subgrade // ~/ . \.. . /
8 Stabilized Subgrade ~' / Craig E. Dunkelberger, P.E.
9 Base Course FL Regjstration No. 49932
10 Other: Footin Sub rade .
Note: The original of this report was signed and sealed by a registered engineer in accordance with Rule 61G15-18.011 of the Flori~'UNn1ilis&ti_e.
This report is submitted as the confidential property of our client and authorization for publication of statements, conc!us¡ons~or extracts from or regarding
this report is reserved pending our written approval. The above-referenced testing was performed at the locations and depth interval described therein on
the associated report date, No other warranties with regard to subsurface exploration, recommendations or design. are expressed by this firm.
Tests I -2: Inches below top of slab subgrade
Tests 3-4: Inches below top of footing subgrade
cc: Centex Homes, David Donvito... (1)
Centex Homes, Eric Otto (site trailer). ..(2)
S1. Lucie County, Building Inspections... (])
607 NW CommodityCove, PortSt. Lucie, Florida 34986 . Phone: (772) 343-9787 . Fax: (772) 343-9404
State of Florida Board of Professional Engineers Authorization No. 6870
01 OS-(j -, 0
8t Lucie County Inspections
2300 Virginia A venue
Ft Pierce, FL 34982
(772) 462-2172
JOB ADDRESS
~t ~ f:\,\< 4J
PERMIT # ~J IA
{
C ~"r"\ ~~
r
PEST CONTROL CONTRACTOR_\-\ 0 ~ -'\ t ~~
~F ~l bY
I. CERTIFICA TE OF TERMITE TREA TMENT
CONSTRUCTION SOIL TREATMENT
BUILDER
~ Jl .~ .-t
~G.ç~~
PEST CONTROL LICENSE #
We, the undersigned, hereby certify that we have pretreated the above-described construction for
subterranean termites in accordance with the standards of the National st Control Association.,
Square feet of area treated: _11-1 '1
Chemicals used:
"(-V \:j ~ \ei
'ìÚ G£11
~~ : 3D
Percentage of solution:
rS
LI('{!Dl
I
Total gallons used:
Date of treatment:
~o~
..E:í 1st Treatment
_ ./ D Re-treat
CdSla~
~ 18t Treatment
D Re-treat
o Driveway
D 1 st Treatment
D Re-treat
D Pools
D 1st Treatment
D Re-trec
D Other ' \" e4.~~
d 1st Treatment '
D Re-treat
D Perimeter for Final Inspection
Time of Treatment:
FRCt 04.2.6 Certificate of Protective Treatment for prevention of termites.
A weather resistant jobsite posting board shall be provided to receive
duplicate Treatment Certificates as each required protective treatment is
completed, providing a copy for the person the permit is issued to and
another copy for the building permit files. The Treatment Certificate shall
provide the product used, identity of the applicator, time and date of the
treatment, site location, area treated, .chemical used, percent concentration
and number of gallons used, to establish a verifiable record of protective
treatment. If the soil chemical barrier method for termite prevention is used,
final exterior treatment shall be completed prior to final building approval.
St Lucie County requires for the final inspection for CO, a Permanent
Sticker to be placed on the electrical panel box cover, listing all the
treatments and dates of applications.
NOTE:
There 11lust be a completed form for each required treatment or re-treatment and this fonn must be on
the job site to be picked up by the inspector at time of each inspection or the scheduled inspection will
fail and a re-illspection fee charged.