HomeMy WebLinkAboutSTEFANAKIS- ENERGY CALCEnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 62/7/2020 9:01 AM
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
GEORGE AND HELEN STEFANIAKIS
STEFANAKIS RESIDENCE
Street:
City, State, Zip: FORT PIERCE , FL ,
S. INDIAN RIVER DRIVE
Permit Number:
Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft²)
New (From Plans)
Single-family
1
No
2032
7. Windows
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
d. U-Factor:
S H G C :
Sgl, U=0.65 155.00 ft²
SHGC=0.30
Sgl, U=0.65 93.13 ft²
SHGC=0.25
N/A f t ²
N/A f t ²
8. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
R=0.0 2032.00 ft²
R=f t ²
R=f t ²
9. Wall Types
a. Concrete Block - Polystyrene Bead AggreR=4.1 1567.00 ft²
b. Frame - Wood, Adjacent R=11.0 420.00 ft²
c. Frame - Wood, Adjacent R=1.0 18.67 ft²
10. Ceiling Types
a. Roof Deck (Unvented)R=20.0 2032.00 ft²
f t ² R=b. N/A
c. N/A R = f t ²
11. Ducts
a. Sup: Attic, Ret: Attic, AH: AHU CLST
12. Cooling systems
13. Heating systems
14. Hot water systems
a. Electric Cap: 1 gallons
b. Conservation features
None
d. N/A R=f t ²
Area Weighted Average Overhang Depth:7.106 ft.
Area Weighted Average SHGC:0.281
Description Area
Insulation Area
Insulation Area
Insulation Area
15. Credits None
3
(248.1 sqft.)
(2005.7 sqft.)
(2032.0 sqft.)
(2032.0 sqft.)
Conditioned floor area below grade (ft²) 0
a. Central Unit
a. Electric Strip Heat
k B t u / h r
29.4 SEER:16.00
Efficiency
k B t u / h r Efficiency
27.0 COP:1.00
f t ² R
6 140
Tankless
EF: 0.900
Glass/Floor Area: 0.122
Total Proposed Modified Loads:
Total Baseline Loads:
64.51
66.61 PASS
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
BUILDING OFFICIAL:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
FORM R405-2017
2-10-20
PROJECT
Title:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
1
GEORGE AND HELEN STEF
STEFANAKIS RESIDENCE
Family Type:
New/Existing:
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle:0
No
1
2032
3
New (From Plans)
Single-family
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
FL ,
FORT PIERCE ,
St. Lucie
S. INDIAN RIVER DRIV
Street Address
Comment:
Building Type: User
Cross Ventilation:No
Whole House Fan:No
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer
CLIMATE
90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______
Number Name Area Volume
BLOCKS
1 Entire House 2032 19778.6
Number Name Area Volume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
1 BEDROOM 2 159 1478.7 No 0 1 Yes Yes1 Yes
2 CLST 2 20 186 No 0 Yes Yes1 Yes
3 BATH 25 233 No 0 Yes Yes1 Yes
4 SINKS 25 232.5 No 0 Yes Yes1 No
5 PANTRY 78 725.4 No 0 Yes Yes1 Yes
6 BEDROOM 3 151 1404.3 No 0 1 Yes Yes1 Yes
7 CLST 3 15 139.5 No 0 Yes Yes1 No
8 AHU CLST 8 74.4 No 0 Yes Yes1 No
9 LINEN 20 186 No 0 Yes Yes1 No
10 LAUNDRY 118 1097.4 No 0 Yes Yes1 No
11 KITCHEN 170 1581 Yes 0 Yes Yes1 Yes
12 GREAT ROOM 549 5654.7 No 0 Yes Yes1 Yes
13 M HALL 68 632.4 No 0 Yes Yes1 No
14 HALL 64 595.2 No 0 Yes Yes1 No
15 M BATH 155 1441.5 No 0 Yes Yes1 Yes
16 M TOILET 15 139.5 No 0 Yes Yes1 No
17 M WIC 2 30 279 No 0 Yes Yes1 No
18 M WIC 1 30 279 No 0 Yes Yes1 Yes
19 MASTER BEDROO 332 3419.6 No 0 1 Yes Yes1 Yes
2/7/2020 9:01 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
1 159 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -025 ft BEDROOM 2
2 20 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -02 ft CLST 2
3 25 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -05 ft BATH
4 25 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft SINKS
5 78 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -06 ft PANTRY
6 151 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -010.9 ft BEDROOM 3
7 15 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft CLST 3
8 8 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft AHU CLST
9 20 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft LINEN
10 118 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft LAUNDRY
11 170 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -010 ft KITCHEN
12 549 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -047 ft GREAT ROOM
13 68 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft M HALL
14 64 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft HALL
15 155 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -011 ft M BATH
16 15 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft M TOILET
17 30 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft M WIC 2
18 30 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -06 ft M WIC 1
19 332 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -036 ft MASTER BEDRO
# Type Materials Color Absor.
Roof Solar Deck
Insul.
Pitch
ROOF
Tested
Roof
Area
Gable
Area
Emitt
Tested
EmittSA
(deg)
Rad
Barr
1 Hip Metal 2273 ft² Light 0.2 20 26.6______No0 ft² 0.9 NoN
ATTIC
# Type Ventilation Area RBS IRCCVent Ratio (1 in)
______ 1 Full attic Unvented 2032 ft² N N0
2/7/2020 9:01 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# Ceiling Type R-Value Area Framing Frac Truss Type
CEILING
Space Ins Type
1 Under Attic (Unvented)0 159 ft² 0.1 Wood______BEDROOM 2 Blown
2 Under Attic (Unvented)0 20 ft² 0.1 Wood______CLST 2 Blown
3 Under Attic (Unvented)0 25 ft² 0.1 Wood______BATH Blown
4 Under Attic (Unvented)0 25 ft² 0.1 Wood______SINKS Blown
5 Under Attic (Unvented)0 78 ft² 0.1 Wood______PANTRY Blown
6 Under Attic (Unvented)0 151 ft² 0.1 Wood______BEDROOM 3 Blown
7 Under Attic (Unvented)0 15 ft² 0.1 Wood______CLST 3 Blown
8 Under Attic (Unvented)0 8 ft² 0.1 Wood______AHU CLST Blown
9 Under Attic (Unvented)0 20 ft² 0.1 Wood______LINEN Blown
10 Under Attic (Unvented)0 118 ft² 0.1 Wood______LAUNDRY Blown
11 Under Attic (Unvented)0 170 ft² 0.1 Wood______KITCHEN Blown
12 Under Attic (Unvented)0 549 ft² 0.1 Wood______GREAT ROOM Blown
13 Under Attic (Unvented)0 68 ft² 0.1 Wood______M HALL Blown
14 Under Attic (Unvented)0 64 ft² 0.1 Wood______HALL Blown
15 Under Attic (Unvented)0 155 ft² 0.1 Wood______M BATH Blown
16 Under Attic (Unvented)0 15 ft² 0.1 Wood______M TOILET Blown
17 Under Attic (Unvented)0 30 ft² 0.1 Wood______M WIC 2 Blown
18 Under Attic (Unvented)0 30 ft² 0.1 Wood______M WIC 1 Blown
19 Under Attic (Unvented)0 332 ft² 0.1 Wood______MASTER BEDRO Blown
WALLS
#Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
1 4.1 0BEDROOM 2 04012 9S Concrete Block - Polystyrene 0.20Exterior112.0 ft² ____
2 4.1 0BEDROOM 2 04013 9W Concrete Block - Polystyrene 0.20Exterior121.3 ft² ____
3 4.1 0CLST 2 0402 9S Concrete Block - Polystyrene 0.20Exterior18.7 ft² ____
4 4.1 0BATH0405 9S Concrete Block - Polystyrene 0.20Exterior46.7 ft² ____
5 4.1 0PANTRY0406 9S Concrete Block - Polystyrene 0.20Exterior56.0 ft² ____
6 4.1 0BEDROOM 3 04011 9W Concrete Block - Polystyrene 0.20Exterior102.7 ft² ____
7 11 0BEDROOM 3 04014 9N Frame - Wood 0.20.1Garage130.7 ft² ____
8 11 0CLST 3 0403 9E Frame - Wood 0.20.1Garage28.0 ft² ____
9 11 0CLST 3 0402 9N Frame - Wood 0.20.1Garage18.7 ft² ____
10 11 0AHU CLST 0402 9N Frame - Wood 0.20.1Garage18.7 ft² ____
11 11 0LAUNDRY04011 9W Frame - Wood 0.20.1Garage102.7 ft² ____
12 1 0LAUNDRY0402 9N Frame - Wood 0.20.1Garage18.7 ft² ____
13 4.1 0KITCHEN04010 9S Concrete Block - Polystyrene 0.20Exterior93.3 ft² ____
14 4.1 0GREAT ROO 04027 10E Concrete Block - Polystyrene 0.20Exterior279.0 ft² ____
15 4.1 0GREAT ROO 04020 10S Concrete Block - Polystyrene 0.20Exterior206.7 ft² ____
16 4.1 0M BATH 04011 9N Concrete Block - Polystyrene 0.20Exterior102.7 ft² ____
17 11 0M BATH 04013 9W Frame - Wood 0.20.1Garage121.3 ft² ____
18 4.1 0M WIC 1 0406 9N Concrete Block - Polystyrene 0.20Exterior56.0 ft² ____
19 4.1 0MASTER BE 04018 10N Concrete Block - Polystyrene 0.20Exterior186.0 ft² ____
20 4.1 0MASTER BE 04018 10E Concrete Block - Polystyrene 0.20Exterior186.0 ft² ____
2/7/2020 9:01 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
#Door Type U-Value AreaStorms
DOORS
Ornt Space Width
Ft In Ft In
Height
1 Insulated .39 20 ft² None______E GREAT ROO 863
# Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered, Proposed orientation.
Wall
ID Imp
1 S Low-E Single 0.65 0.25 12.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes1 N
2 W Low-E Single 0.65 0.25 7.8 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes2 N
3 S Low-E Single 0.65 0.25 6.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes4 N
4 W Low-E Single 0.65 0.25 15.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes6 N
5 S Low-E Single 0.65 0.25 9.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes13 N
6 E Low-E Single 0.65 0.25 13.3 ft² 10 ft 0 in 1 ft 4 in NoneMetal None______Yes14 N
7 E Low-E Single 0.65 0.3 80.0 ft² 10 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes14 N
8 S Low-E Single 0.65 0.3 30.0 ft² 10 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes15 N
9 N Low-E Single 0.65 0.25 10.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes16 N
10 N Low-E Single 0.65 0.25 20.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes19 N
11 E Low-E Single 0.65 0.3 45.0 ft² 10 ft 0 in 1 f t 4 in NoneMetal None______Yes20 N
# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
GARAGE
1 480 ft² 480 ft² 44 ft 9 ft 11______
Method CFM 50 ACH 50ELASLAScope
INFILTRATION
ACHEqLA#
2307.6 7126.68.000433Wholehouse .1623238.24Proposed ACH(50)1
HEATING SYSTEM
# System Type Efficiency Capacity DuctsSubtypeBlockSpeed
1 Electric Strip Heat/COP:1 27 kBtu/hr ______sys#1None1
# System Type Efficiency Capacity Air Flow SHR
COOLING SYSTEM
DuctsSubtypeBlockSubtype
1 Central Unit/SEER: 16 29.4 kBtu/hr 882 cfm 0.8______sys#1Split1 Single
# System Type EF Cap Use SetPnt Conservation
HOT WATER SYSTEM
SubType Location
1 Electric 0.9 1 gal 60.9 gal 120 deg None______Tankless Exterior
2/7/2020 9:01 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FSEC
Company Name System Model #Collector Model #
Collector
SOLAR HOT WATER SYSTEM
Storage
FEFCert #Area Volume
None None f t ² ______
# Location R-Value Area Location Area
---- Supply -------- Return ----
Leakage Type Handler
CFM 25Air
QN RLF
DUCTS
Heat Cool
HVAC #
TOT OUT
CFM25
1 Attic 6 140 ft² Attic 14 ft² Default Leakage AHU CLST (Default) c______1 1 (Default) c
TEMPERATURES
Programable Thermostat: N Ceiling Fans:
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] Dec
[X] Dec[X] Nov
[X] Nov
[ ] Oct
[X] Oct
[ ] Sep
[ ] Sep
[ ] Aug
[ ] Aug
[ ] Jul
[ ] Jul[ ] Jun
[ ] Jun
[X] Jun
[ ] May
[ ] May
[ ] Apr
[X] Apr
[X] Mar
[X] Mar
[X] Feb
[ ] Feb
[X] Jan
[ ] Jan
Heating
Venting
Thermostat Schedule:HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling (WD)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Cooling (WEH)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Heating (WD)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 BEDROOM 2
Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 2
Default(8 lbs/sq.ft.f t ² f t 0.3 BATH
Default(8 lbs/sq.ft.f t ² f t 0.3 SINKS
Default(8 lbs/sq.ft.f t ² f t 0.3 PANTRY
Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 3
Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 3
Default(8 lbs/sq.ft.f t ² f t 0.3 AHU CLST
Default(8 lbs/sq.ft.f t ² f t 0.3 LINEN
Default(8 lbs/sq.ft.f t ² f t 0.3 LAUNDRY
Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN
Default(8 lbs/sq.ft.f t ² f t 0.3 GREAT ROOM
Default(8 lbs/sq.ft.f t ² f t 0.3 M HALL
Default(8 lbs/sq.ft.f t ² f t 0.3 HALL
Default(8 lbs/sq.ft.f t ² f t 0.3 M BATH
Default(8 lbs/sq.ft.f t ² f t 0.3 M TOILET
Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC 2
Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC 1
Default(8 lbs/sq.ft.f t ² f t 0.3 MASTER BEDROO
2/7/2020 9:01 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
���������������������������������������������������������������������������
���������������������������������������������������������������������������������
�����������������������������������������������������