Loading...
HomeMy WebLinkAboutSTEFANAKIS- ENERGY CALCEnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 62/7/2020 9:01 AM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY GEORGE AND HELEN STEFANIAKIS STEFANAKIS RESIDENCE Street: City, State, Zip: FORT PIERCE , FL , S. INDIAN RIVER DRIVE Permit Number: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) New (From Plans) Single-family 1 No 2032 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : d. U-Factor: S H G C : Sgl, U=0.65 155.00 ft² SHGC=0.30 Sgl, U=0.65 93.13 ft² SHGC=0.25 N/A f t ² N/A f t ² 8. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 2032.00 ft² R=f t ² R=f t ² 9. Wall Types a. Concrete Block - Polystyrene Bead AggreR=4.1 1567.00 ft² b. Frame - Wood, Adjacent R=11.0 420.00 ft² c. Frame - Wood, Adjacent R=1.0 18.67 ft² 10. Ceiling Types a. Roof Deck (Unvented)R=20.0 2032.00 ft² f t ² R=b. N/A c. N/A R = f t ² 11. Ducts a. Sup: Attic, Ret: Attic, AH: AHU CLST 12. Cooling systems 13. Heating systems 14. Hot water systems a. Electric Cap: 1 gallons b. Conservation features None d. N/A R=f t ² Area Weighted Average Overhang Depth:7.106 ft. Area Weighted Average SHGC:0.281 Description Area Insulation Area Insulation Area Insulation Area 15. Credits None 3 (248.1 sqft.) (2005.7 sqft.) (2032.0 sqft.) (2032.0 sqft.) Conditioned floor area below grade (ft²) 0 a. Central Unit a. Electric Strip Heat k B t u / h r 29.4 SEER:16.00 Efficiency k B t u / h r Efficiency 27.0 COP:1.00 f t ² R 6 140 Tankless EF: 0.900 Glass/Floor Area: 0.122 Total Proposed Modified Loads: Total Baseline Loads: 64.51 66.61 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2017 2-10-20 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY 1 GEORGE AND HELEN STEF STEFANAKIS RESIDENCE Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle:0 No 1 2032 3 New (From Plans) Single-family Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , FORT PIERCE , St. Lucie S. INDIAN RIVER DRIV Street Address Comment: Building Type: User Cross Ventilation:No Whole House Fan:No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer CLIMATE 90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______ Number Name Area Volume BLOCKS 1 Entire House 2032 19778.6 Number Name Area Volume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 BEDROOM 2 159 1478.7 No 0 1 Yes Yes1 Yes 2 CLST 2 20 186 No 0 Yes Yes1 Yes 3 BATH 25 233 No 0 Yes Yes1 Yes 4 SINKS 25 232.5 No 0 Yes Yes1 No 5 PANTRY 78 725.4 No 0 Yes Yes1 Yes 6 BEDROOM 3 151 1404.3 No 0 1 Yes Yes1 Yes 7 CLST 3 15 139.5 No 0 Yes Yes1 No 8 AHU CLST 8 74.4 No 0 Yes Yes1 No 9 LINEN 20 186 No 0 Yes Yes1 No 10 LAUNDRY 118 1097.4 No 0 Yes Yes1 No 11 KITCHEN 170 1581 Yes 0 Yes Yes1 Yes 12 GREAT ROOM 549 5654.7 No 0 Yes Yes1 Yes 13 M HALL 68 632.4 No 0 Yes Yes1 No 14 HALL 64 595.2 No 0 Yes Yes1 No 15 M BATH 155 1441.5 No 0 Yes Yes1 Yes 16 M TOILET 15 139.5 No 0 Yes Yes1 No 17 M WIC 2 30 279 No 0 Yes Yes1 No 18 M WIC 1 30 279 No 0 Yes Yes1 Yes 19 MASTER BEDROO 332 3419.6 No 0 1 Yes Yes1 Yes 2/7/2020 9:01 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 1 159 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -025 ft BEDROOM 2 2 20 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -02 ft CLST 2 3 25 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -05 ft BATH 4 25 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft SINKS 5 78 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -06 ft PANTRY 6 151 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -010.9 ft BEDROOM 3 7 15 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft CLST 3 8 8 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft AHU CLST 9 20 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft LINEN 10 118 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft LAUNDRY 11 170 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -010 ft KITCHEN 12 549 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -047 ft GREAT ROOM 13 68 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft M HALL 14 64 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft HALL 15 155 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -011 ft M BATH 16 15 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft M TOILET 17 30 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft M WIC 2 18 30 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -06 ft M WIC 1 19 332 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -036 ft MASTER BEDRO # Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1 Hip Metal 2273 ft² Light 0.2 20 26.6______No0 ft² 0.9 NoN ATTIC # Type Ventilation Area RBS IRCCVent Ratio (1 in) ______ 1 Full attic Unvented 2032 ft² N N0 2/7/2020 9:01 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Unvented)0 159 ft² 0.1 Wood______BEDROOM 2 Blown 2 Under Attic (Unvented)0 20 ft² 0.1 Wood______CLST 2 Blown 3 Under Attic (Unvented)0 25 ft² 0.1 Wood______BATH Blown 4 Under Attic (Unvented)0 25 ft² 0.1 Wood______SINKS Blown 5 Under Attic (Unvented)0 78 ft² 0.1 Wood______PANTRY Blown 6 Under Attic (Unvented)0 151 ft² 0.1 Wood______BEDROOM 3 Blown 7 Under Attic (Unvented)0 15 ft² 0.1 Wood______CLST 3 Blown 8 Under Attic (Unvented)0 8 ft² 0.1 Wood______AHU CLST Blown 9 Under Attic (Unvented)0 20 ft² 0.1 Wood______LINEN Blown 10 Under Attic (Unvented)0 118 ft² 0.1 Wood______LAUNDRY Blown 11 Under Attic (Unvented)0 170 ft² 0.1 Wood______KITCHEN Blown 12 Under Attic (Unvented)0 549 ft² 0.1 Wood______GREAT ROOM Blown 13 Under Attic (Unvented)0 68 ft² 0.1 Wood______M HALL Blown 14 Under Attic (Unvented)0 64 ft² 0.1 Wood______HALL Blown 15 Under Attic (Unvented)0 155 ft² 0.1 Wood______M BATH Blown 16 Under Attic (Unvented)0 15 ft² 0.1 Wood______M TOILET Blown 17 Under Attic (Unvented)0 30 ft² 0.1 Wood______M WIC 2 Blown 18 Under Attic (Unvented)0 30 ft² 0.1 Wood______M WIC 1 Blown 19 Under Attic (Unvented)0 332 ft² 0.1 Wood______MASTER BEDRO Blown WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 4.1 0BEDROOM 2 04012 9S Concrete Block - Polystyrene 0.20Exterior112.0 ft² ____ 2 4.1 0BEDROOM 2 04013 9W Concrete Block - Polystyrene 0.20Exterior121.3 ft² ____ 3 4.1 0CLST 2 0402 9S Concrete Block - Polystyrene 0.20Exterior18.7 ft² ____ 4 4.1 0BATH0405 9S Concrete Block - Polystyrene 0.20Exterior46.7 ft² ____ 5 4.1 0PANTRY0406 9S Concrete Block - Polystyrene 0.20Exterior56.0 ft² ____ 6 4.1 0BEDROOM 3 04011 9W Concrete Block - Polystyrene 0.20Exterior102.7 ft² ____ 7 11 0BEDROOM 3 04014 9N Frame - Wood 0.20.1Garage130.7 ft² ____ 8 11 0CLST 3 0403 9E Frame - Wood 0.20.1Garage28.0 ft² ____ 9 11 0CLST 3 0402 9N Frame - Wood 0.20.1Garage18.7 ft² ____ 10 11 0AHU CLST 0402 9N Frame - Wood 0.20.1Garage18.7 ft² ____ 11 11 0LAUNDRY04011 9W Frame - Wood 0.20.1Garage102.7 ft² ____ 12 1 0LAUNDRY0402 9N Frame - Wood 0.20.1Garage18.7 ft² ____ 13 4.1 0KITCHEN04010 9S Concrete Block - Polystyrene 0.20Exterior93.3 ft² ____ 14 4.1 0GREAT ROO 04027 10E Concrete Block - Polystyrene 0.20Exterior279.0 ft² ____ 15 4.1 0GREAT ROO 04020 10S Concrete Block - Polystyrene 0.20Exterior206.7 ft² ____ 16 4.1 0M BATH 04011 9N Concrete Block - Polystyrene 0.20Exterior102.7 ft² ____ 17 11 0M BATH 04013 9W Frame - Wood 0.20.1Garage121.3 ft² ____ 18 4.1 0M WIC 1 0406 9N Concrete Block - Polystyrene 0.20Exterior56.0 ft² ____ 19 4.1 0MASTER BE 04018 10N Concrete Block - Polystyrene 0.20Exterior186.0 ft² ____ 20 4.1 0MASTER BE 04018 10E Concrete Block - Polystyrene 0.20Exterior186.0 ft² ____ 2/7/2020 9:01 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT #Door Type U-Value AreaStorms DOORS Ornt Space Width Ft In Ft In Height 1 Insulated .39 20 ft² None______E GREAT ROO 863 # Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1 S Low-E Single 0.65 0.25 12.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes1 N 2 W Low-E Single 0.65 0.25 7.8 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes2 N 3 S Low-E Single 0.65 0.25 6.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes4 N 4 W Low-E Single 0.65 0.25 15.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes6 N 5 S Low-E Single 0.65 0.25 9.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes13 N 6 E Low-E Single 0.65 0.25 13.3 ft² 10 ft 0 in 1 ft 4 in NoneMetal None______Yes14 N 7 E Low-E Single 0.65 0.3 80.0 ft² 10 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes14 N 8 S Low-E Single 0.65 0.3 30.0 ft² 10 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes15 N 9 N Low-E Single 0.65 0.25 10.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes16 N 10 N Low-E Single 0.65 0.25 20.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes19 N 11 E Low-E Single 0.65 0.3 45.0 ft² 10 ft 0 in 1 f t 4 in NoneMetal None______Yes20 N # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation GARAGE 1 480 ft² 480 ft² 44 ft 9 ft 11______ Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 2307.6 7126.68.000433Wholehouse .1623238.24Proposed ACH(50)1 HEATING SYSTEM # System Type Efficiency Capacity DuctsSubtypeBlockSpeed 1 Electric Strip Heat/COP:1 27 kBtu/hr ______sys#1None1 # System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtypeBlockSubtype 1 Central Unit/SEER: 16 29.4 kBtu/hr 882 cfm 0.8______sys#1Split1 Single # System Type EF Cap Use SetPnt Conservation HOT WATER SYSTEM SubType Location 1 Electric 0.9 1 gal 60.9 gal 120 deg None______Tankless Exterior 2/7/2020 9:01 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FSEC Company Name System Model #Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert #Area Volume None None f t ² ______ # Location R-Value Area Location Area ---- Supply -------- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 140 ft² Attic 14 ft² Default Leakage AHU CLST (Default) c______1 1 (Default) c TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec [X] Dec[X] Nov [X] Nov [ ] Oct [X] Oct [ ] Sep [ ] Sep [ ] Aug [ ] Aug [ ] Jul [ ] Jul[ ] Jun [ ] Jun [X] Jun [ ] May [ ] May [ ] Apr [X] Apr [X] Mar [X] Mar [X] Feb [ ] Feb [X] Jan [ ] Jan Heating Venting Thermostat Schedule:HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Heating (WD)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 2 Default(8 lbs/sq.ft.f t ² f t 0.3 BATH Default(8 lbs/sq.ft.f t ² f t 0.3 SINKS Default(8 lbs/sq.ft.f t ² f t 0.3 PANTRY Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 3 Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 3 Default(8 lbs/sq.ft.f t ² f t 0.3 AHU CLST Default(8 lbs/sq.ft.f t ² f t 0.3 LINEN Default(8 lbs/sq.ft.f t ² f t 0.3 LAUNDRY Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN Default(8 lbs/sq.ft.f t ² f t 0.3 GREAT ROOM Default(8 lbs/sq.ft.f t ² f t 0.3 M HALL Default(8 lbs/sq.ft.f t ² f t 0.3 HALL Default(8 lbs/sq.ft.f t ² f t 0.3 M BATH Default(8 lbs/sq.ft.f t ² f t 0.3 M TOILET Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC 2 Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC 1 Default(8 lbs/sq.ft.f t ² f t 0.3 MASTER BEDROO 2/7/2020 9:01 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT ��������������������������������������������������������������������������� ��������������������������������������������������������������������������������� �����������������������������������������������������