Loading...
HomeMy WebLinkAboutLighting Project DEER MOSS-TALLOWOOD-WEST HAMMOCK SITE LIGHTING-1-29-20 UPDTDSTREET LIGITIN G FUR HARBOR RIDGE DEER MOSS , TALLOWOOD & WEST HA MMOCK VILLAGE PALM CITY, FLORIDA DATE: JANUARY 28,2020 SHEET INDEX DESCRIPTION E—OA GENERAL NOTES, SPECIFICATIONS, LEGENDS, INDEX E-01 DEER MOSS VILLAGE — OVERALL SITE LIGHTING PLAN E-02 DEER MOSS VILLAGE — ENLARGED SITE LIGHTING PLAN E-03 TALLOWOOD VILLAGE — OVERALL SITE LIGHTING PLAN E-04 TALLOWOOD VILLAGE — ENLARGED SITE LIGHTING PLAN E-05 TALLOWOOD VILLAGE — ENLARGED SITE LIGHTING PLAN E-06 WEST HAMMOCK VILLAGE — OVERALL SITE LIGHTING PLAN E-07 WEST HAMMOCK VILLAGE — ENLARGED SITE LIGHTING PLAN LOCATION MAY NOT TO SCALE 0 0 KEY WESTqkp �aoo 00 9 �o Da CRRoinFIL EnainEERm RSSOCIRTES Inc 575 NW MERCANTILE PL SUITE 106 PORT ST. LUCIE FL 34986 T.561.746.6343 F.561.746.3602 info@CEAengineers.com CA LIC. 31555 1�� HARe❑UR F21IDEiE TAG HT fi GilLIM7RY GLLI Ei PROPOSED STREET LIGHTING FOR DEER MOSS, TALLOWWOOD & WEST HAMMOCK VILLAGE PALM CITY, FL JOSEPH L. LAMMERS ,PE PE # 78477 SEAL , QC 2020 CARDINAL ENGINEERING ASSOCIATES, INC. THIS DOCUMENT, SHEET NO. HAS BEEN PREPARED SPECIFICALLY FOR THIS PROJECT. THIS DOCUMENT IS NOT SUITABLE FOR USE ON OTHER PROJECTS OR IN OTHER LOCATIONS WITHOUT THE APPROVAL AND PARTICIPATION OF CARDINAL ENGINEERING ASSOCIATES. UNAUTHORIZED REPRODUCTION AND/OR REUSE IS PROHIBITED. SHEET TITLE: COVER SHEET REVISIONS: DESIGN BY: DATE: DJL 01/28/2020 DRAWN BY: CHECKED: NL JL COVER OF 8 SHEETS I WEST HAMMOCK I O VILLAGE I I I I I I I I I 7 E— 06 E-07 I I I I I ELECTRICAL SYMBOL LEGEND SYMBOL DESCRIPTION ^ PANELBOARDS, SEE SCHEDULES LIGHT POLE ❑ TC TIME CLOCK SWITCH, 4P-ASTRONOMIC W/RESERVE TRANSFORMER EX EXISTING LIGHT FIXTURE TAG MINIMUM CONDUCTOR SIZING FOR 120V 1 0 BRANCH CIRCUITS (FOR FBC 13-413.13C.1.2 COMPLIANCE) DESIGN LOAD ON CIRCUIT IN VA (FROM PANELBOARD SCHEDULE) UP TO: 500 1000 1500 2000 2500 3000 50' 12 12 12 10 10 10 fx o) 100' 12 12 10 8 8 6 0-6 150' 12 10 8 6 6 4 F- 200' 10 8 6 4 4 4 W 250' 10 6 6 4 4 3 J 300' 1 8 1 6 1 4 1 4 1 3 1 2 MINIMUM CONDUCTOR SIZING FOR 240V/1 0 BRANCH CIRCUITS (FOR FBC 13-413.BC.1.2 COMPLIANCE) DESIGN LOAD ON CIRCUIT IN VA (FROM PANELBOARD SCHEDULE) UP TO: 1000 1 1500 1 2000 1 2500 1 3000 1 3500 1 4000 4500 5000 501 12 1 12 1 12 1 12 1 12 1 10 1 10 1 10 8 ..... n 4 n 1 4 n 1 4 n 1 4 n 1 4 n 1 4 n 1 4 n O ELECTRICAL NOTES THESE NOTES APPLY TO ENTIRE PROJECT: A. CODES. ALL ELECTRICAL WORK SHALL COMPLY WITH THE DRAWINGS AND SPECIFICATIONS, THE NATIONAL ELECTRICAL CODE AND APPLICABLE LOCAL CODES, WHICHEVER IS MORE STRINGENT. B. ENERGY CODE. LIGHT FIXTURES ARE TO COMPLY WITH THE FLORIDA ENERGY CODE. FULL COMPLIANCE WITH THE ENERGY CODE IS REQUIRED, WITH PROVISIONS FOR AUTOMATIC SHUT OFF OF LIGHTING. C. CONDUCTORS. ALL CONDUCTORS ARE TO BE COPPER THWN-2 UNLESS OTHERWISE SHOWN OR REQUIRED BY CODES. ALL POWER CONDUITS ARE TO CONTAIN A GROUND WIRE. D. RACEWAYS. PVC SCHEDULE 40 CONDUIT IS TO BE USED OUTDOORS. E. POWER COMPANY. THE ELECTRICAL CONTRACTOR IS TO COORDINATE ALL SERVICE REQUIREMENTS WITH THE POWER COMPANY BEFORE BIDDING TO BE CERTAIN ALL WORK NECESSARY TO MEET POWER COMPANY SPECIFICATIONS IS IN THE BID. ALL ELECTRICAL GEAR SHALL BE APPROVED BY THE POWER COMPANY. THE ELECTRICAL CONTRACTOR SHALL MEET WITH THE POWER COMPANY PRIOR TO BIDDING TO DETERMINE ALL FEATURES, FUNCTIONS AND LOCATIONS OF SERVICE. FURTHERMORE, THE ELECTRICAL CONTRACTOR IS TO MAINTAIN CONTINUOUS CONTACT WITH THE POWER COMPANY DURING THE PROJECT, AND IS TO NOTIFY THE ENGINEER IMMEDIATELY OF ANY CHANGE PROPOSED. THE ELECTRICAL CONTRACTOR SHALL COORDINATE THE SERVICE THOROUGHLY AND DOCUMENT THE COORDINATION. F. SCALES. DO NOT SCALE OR TAKE DIMENSIONS FROM ELECTRICAL DRAWINGS. G. UNDERGROUND WORK. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DETERMINING THE EXACT ROUTES OF ALL UNDERGROUND WORK. ROUTES SHOWN ARE APPROXIMATE. POWER, TELEPHONE, CABLE COMPANIES, AND ALL OTHER UTILITY COMPANIES SHALL BE CONSULTED, AND LINES SHALL BE STAKED. DIGGING BY HAND IS REQUIRED AROUND EXISTING UTILITIES. H. LIGHT FIXTURE VOLTAGES. OBTAIN LIGHT FIXTURE VOLTAGES FROM CIRCUITS ON PLANS. DO NOT OBTAIN FROM MODEL NUMBERS ON LIGHT FIXTURE SCHEDULE S. COMPLETION REQUIREMENTS. WITHIN 30 DAYS AFTER SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED BY THE CONTRACTOR TO BUILDING OWNER WITH A SINGLE LINE DIAGRAM OF THE DISTRIBUTION SYSTEM PLUS FLOOR PLANS SHOWING LOCATIONS AND AREAS SERVED. APPLICABLE BUILDING CODES FLORIDA BUILDING CODE, 6TH EDITION (2017) NFPA 70, NATIONAL ELECTRICAL CODE (2014) FLORIDA FIRE PREVENTION CODE, 6TH EDITION (2017) FLORIDA ENERGY CONSERVATION CODE, 6TH EDITION (2017) LIGHT FIXTURE SCHEDULE O ARCHITECTURAL AREA LIGHTING #PROV—T3-32LED-4K-450—DB—DF—STND—MNT—AD5— WIRED 120-277V WITH POLE #DB25F10-188—PTF—DB—ABT © ARCHITECTURAL AREA LIGHTING #PROV—T3-32LED-4K-450—DB—DF—STND—MNT—AD5— WIRED 120-277V WITH POLE B U TTO N B U S H #DB25F12-188—PTF—DB—ABT VILLAGE I °v E-01 E-02 SCOPE OF WORK THIS PROJECT INVOLVES NEW STREET LIGHTING INSTALLATIONS WITH NEW CIRCUITING FROM EXISTING PANELS IN THE DEER MOSS AND TALLOWOOD VILLAGES. THE WEST HAMMOCK VILLAGE HAS EXISTING STREET LIGHTING WHICH IS TO BE REPLACED, USING THE EXISTING CIRCUITING. ELECTRICAL SHEET INDEX SHT NO. DESCRIPTION E—OA GENERAL NOTES, SPECIFICATIONS, LEGENDS, INDEX E-01 DEER MOSS VILLAGE — OVERALL SITE LIGHTING PLAN E-02 DEER MOSS VILLAGE — ENLARGED SITE LIGHTING PLAN E-03 TALLOWOOD VILLAGE — OVERALL SITE LIGHTING PLAN E-04 TALLOWOOD VILLAGE — ENLARGED SITE LIGHTING PLAN E-05 TALLOWOOD VILLAGE — ENLARGED SITE LIGHTING PLAN E-06 WEST HAMMOCK VILLAGE — OVERALL SITE LIGHTING PLAN E-07 WEST HAMMOCK VILLAGE — ENLARGED SITE LIGHTING PLAN IV PROJECT KEY PLAN NO SCALE DATE I REV NO. CONTRACTOR IS TO PROVIDE FULL LOCATION SERVICE FOR ALL UNDERGROUND UTILITIES IN THE AREA OF CONSTRUCTION. Know what's b@IOW. Call before you dig aa CFIRi3inF1L EncinEERm RSSOCIRTES Inc 575 NW MERCANTILE PL SUITE 106 PORT ST. LUCIE FL 34986 T.561.746.6343 F.561.746.3602 info@CEAengineers.com CA LIC. 31555 10AIIIIIIIIIIIrg- HAREILIUR FZI01iiE TAG HT fi GilLIM7RY 0LLI8 PROPOSED STREET LIGHTING FOR DEER MOSS, TALLOWWOOD & WEST HAMMOCK VILLAGE PALM CITY, FL QC 2020 CARDINAL ENGINEERING ASSOCIATES, INC. THIS DOCUMENT, SHEET NO. HAS BEEN PREPARED SPECIFICALLY FOR THIS PROJECT. THIS DOCUMENT IS NOT SUITABLE FOR USE ON OTHER PROJECTS OR IN OTHER LOCATIONS WITHOUT THE APPROVAL AND PARTICIPATION OF CARDINAL ENGINEERING ASSOCIATES. UNAUTHORIZED REPRODUCTION AND/OR LREUSE IS PROHIBITED. SHEET TITLE: KEY PLAN, NOTES & SCHEDULES REVISIONS: DESIGN BY: DATE: DJL 01/28/2020 DRAWN BY: CHECKED: NIL JL E-OA OF 8 ELECTRICAL SHEETS Submitted by SEFL, Ins. - Catalog Number: Type: Job Name: PR0V-T3-321_ED-4K-4-90-DR-DF �* Harbour Ridge STND MNT-AD5-WIRED120-277V O Notes: SER, iNC.18-22975 Providence®McroCoreT"- Medium Housing PROV TYPE FEATURES • Reliable, uniform, glare free illumination • 0-10V dimming ready • 14 standard powder coat finishes • Types 11, III, IV, V and custom • Integral surge suppression distributions' • LifeShieldT11 thermal protection • 3000K, 4000K, 5000K CCT SPECIFICATIONS 18.7'1475mm • Diameter: 18.7" / 475 min Height: 31.5" 1800 mm • Weight: 29lbs • EPA: 0.96 • IP Rating: 65 31.5'780pmm \LpTTRT�, C \\� us s i9iE11 300OK and warmer =5 on€y ORDERING INFORMATION MODEL 1 2 3 4 5 6 7 } Light Engine CCT Drive Current Finish Options Controls Mounting 1. LIGHT ENGINE 4. FINISH (CONT) 7. MOUNTING T2 Typ811 Premium Color SYandardconh'g�r�liorfstipsovera4"D1Aopentoo pole ormay T3 Type 11l SFM Seafoam choose one. T4 Type 1V SHK Shamrock T5 Type Wall Mount Arm SPP Saltand?epper WMA7 WMA57 WMA35U 2. COLOR TEMPERATURE WCP weathered Copper WMA55 WMA9U WMA36U 321_17D-31< 3000KCCT700HI HAL RAL 4 digit Color WMA66 WMA22LJ 32LED-4K 4000KCCT'70CRI CUSTOM Custom Color 32LED-5K 50 6KCOT 70CR1 S.OPTIONS (may choose asnoted) i Pole Mount Arm manochmma7c TRA5U-4 TRA5U-5 F, use may choose one arnbernalGCTsandquest" amberavailable by requests TRA6U-4 TRA6U-5 _ 3. DRIVE CURRENT DF 208or240LfneVolts TRA55-4 TRA55-5 TRA57-4 TRA57-5 TRA56 700 700mA, 75 wafts i ish SLA1 SLA1-2 450 459mA, 48 mtt6 SPK Decoraf ve spike 4- FINISH BPS Struts painted brass SLASLA2U- SLA22U-2U- 4 SLA22U-5 Standard Color PFN Finial painted brass AGN Antique Green Optics may choose one Pier Mount BL Black LDL Lighaydrfusedlens PM1 PM2 PM3 BLT Matte Black CLR Clear flat lens Option CRT Corten HSS House 5ideshield for Type 4 DB DadrBronze Accessories may choose one AD5 DGN Dark Green I EPA-C Egress-Contemporary"_- LG Light Grey EPA-T Egress -Traditional" NOTE: MAL Matte Aluminum Mounting may choose one T Pole accessoryvrith motion sensor and daylight photo- M DB Itronze Metallic PT23 Slips Dvera 2 318"x 4" Tenon control for California rde 24 swhbn 130.2 compliance. Medium Grey PT3 Slips Over 3 x 4" Tenon For complete spec sheet and ordering information, vr'sit TT TT 7'danium wwsvaalnet/productslsensor..control programmable/ VBJ Verde Blue 6. CONTROL WDB weathered Bronze PCA-C Rotatable photocell -Contemporary ? Handheld cammis nyr tool is required to separately configure or ad/ust anynum6erofSCP sensors Wl1 ArcticWblte PCAT Rotatahle photocell Traditional SCP Sensor Control Programmable, pole s Nat compatible with PCA-C nor PCA-T accessory ordered separately' z ' Consult factory ARCHITECTURALAREALJGHTINGalrCh- -- - -� __O®MWIM% 17750 Howland Street I City of Industry I CA 91748 JOB a eiallg ngl P626.g68.5666 j F626.369.2695 3 www.aal.net TYPE NOTES Copyrfght ®2014 February 15, 2018 8:36 AM I 1 ! submitted b SEFL, Inc. Job Name: Harbour Ridge zr _ C�a_ rs!7ritr�7 yfrag D132 - Decorative Pole I TY€ F 5' ROUND (RD) & FLUTED (FL) DECORATIVE BASE D625 F 10-188-PTF-D B-ABT Notes: Pole height 10' 1. BASE 2. POLE 3. OAH 4. COLOR S. OPTIONSIACCESSORIES 9 sand 1 oni r- rx 1r)A44 MAXIMUM ALLOWABLE EPA (MPH) cuACT 1n nx an inn sin Tan son s.ln 4cA DB2 5R12-188 12' (3.7m) 5" RD x .188" 116 32.3 28.5 22.7 18.6 15.5 13.1 11.2 9.6 DB2 6R14-188 1N (4.3m) 5" RD x.188" 116 32.3 28.5 22.7 18.6 15.5 13.1 11.2 9.6 DB2 5R16-188 16' (4.9m) 5" RD x .188" 123 27.3 23.9 19.0 15.5 12.8 7.9 0132 5R78-188 18' (5.5m) 5" RD x .188" 129 22.8 19.8 15.6 12.7 10.5 _10.8_ 8.8 _9.2_ 7.4 6.4 DB2 5R20-188 20' (6.2m) 5" RD x .188" 136 18.9 16.4 12.8 10.3 8.5 TO 5;9 5.0 DB2 5R22-188 22' (6.8m) 5" RD x .188" 142 15.8 13.5 10A 8.3 6.6 5.6 4.7 3.9 D82 5R24-188 24' (7.4m) 5" RD x .188" 148 13.1 11.1 8,4 6.6 5.3 4.3 3.6' 3.0 ❑B2 5R25-188 25' (7,7m) 5" RD x .188" 151 11.9 10.0 7.5 5.9 4.7 3.8 3.1 2.5 DB2 SR14-250 14' (4,3m) 5" RD x.250" 132 35.7 31.5 25.2 20.6 17.2 14.5 12.4 10.7 ❑B2 5R16-250 16' (4.9m) 5" RD x .250" 140 30.5 26.8 21.3 17.4 14.5 12.2 10.4 9.0 DB2 51118-250 1V (5.5m) 5" RD x.250" 150 25.8 22.5 17.8 14.6 12.0 10.1 8.6 7.3 DB2 5R20-250 20' (6.2m) 5" RD x .250" 158 21.0 18.9 14.8 12.0 9.9 8.3 70 6,0 DB2 SR22-250 22'(6.8m) 5" RD x .250" 167 18.5 15.9 124 g.g 81 6.7 5.7 4.8 DB2 5R24-250 24' (7.4m) 5" RD x .250" 176 15.7 13.4 10.3 8.2 6.6 5.5 4.5 3.8 DB2 D132 5R25-250 51`14-188 25' (7.7m) 14' (4.3m) 5" RD x .250" _ 5" FL x .188" 180 116 14.5 21.4 12.3 18.7 9.3 14.6 7.4 12.1 6.0 10.0 4.9 8.2 4.0 6.9 3.4 5.8 DB2 51`16-188 16' (4.9m) 5" FL x .188" 123 17.8 16.5 12.1 9.8 8.0 6.6 5.4 4.5 DB2 61`18-188 18' (5.5m) ' 5" FL x .188" 129 14.5 12.5 9.7 7.8 6.3 5.1 4.1 3.3 DB2 5F20-188 20' (6.2m) 5" FL x .188" 136 11.8 10.0 7.6 6.1 4.8 3.7 3.0 2,3 D132 5F22-188 22' f6.8m) 5" FL x .188" 142 9.4 7.9 5.8 4.6 3.9 2.6 2.0 1.4 DB2 5F24-188 24' (7.4m) 5" FL x .186" 148 7.4 6.1 4.3 3.3 2.4 1.7 1.1 0.6 D62 5F25-led 25' (7.7M) 5" FL x .188" 151 6.6 5.2 3.6 2.7 1.9 1.2 0.7 0.3 Note: owraffheightis measaredto top ol pole. 2. COLOR Standard Color 3. OPTIONS IACCESSORIES WH Arctic While ADS (This adapter is to be used only with standard AAL arras BL Black and post top mount fixtures that slip avers 4' od poie. The BLT Matte Black AD5 is a cast aluminum adapter that slips into the arm or ovara DB DarkOMM 5'1125rrrm0D.pole.) ➢GN Oark Grew FH(Flag holder. Specifylocation onpoJo) TT Rfanlum 1`51 (Single weathe proof hue holder. Fuse by others.) WD3 WcatheredBmnzo FS2(Ooubleweafherprcaffus8holder fusabyatlrers.J MDB 660,117eMelaliic PCR{tow profile twist laekphoWellreceptadewith castpole VBU Verde Blue cap top. Secures to ft top of the pore Iwtn three stainless sleet CRT Corten setscrews. Photocehbyothers.) MAL ManeAlunimum HBO (Costalurru mmreceptactehausiug, inlegraflywelded to MG Medium Grey the pok. Includes a NEC approved clear weatherproof covar Does not inc,udeareceptacleoridernalwiring.) AGN Antique Green LG Light Grey Premium Color SHK Shaimock SPP 30480pepper SFM Seaton; WCP WealheredCopper RAL RAL4digitColor CUSTOM Custom Color O LIGHT FIXTURE M 0 I 0 WP/GFI DUPLEX RECEPTACLE HAND HOLE - GROUND ARCHITECTURAL AREA LIGHTING 16555 East Gale Ave. I City of Industry I CA 91745 P 626.968,5666 1 F 626.369.2695 1 www.aal.net Copyright C36 2012 I REV 6.12 SPECIFICATIONS Base shall be cast aluminum #356 aliey, free of any porosity, foreign materials, or cosmetic fillers. Base casting shall be heat treated to a T-6 condition, and of uniform wall thickness, with no warping or mold shifting. WARNINGS Caution must be exercised in the selection of a design wind speed when the pole is to be installed in a special wind region (as indicated by the wind map) or in an area where wind speed is unpredictable. AAL recommends consulting a local engineer when the pole is to be installed in an area that may be subject to extreme weather and exposure. Pales installed an structures such as buildings and bridges may be subjected to vibration, oscillations, and other fatigue effects which are not covered by the AAL warranlyThe use of banners or other appendages can severely affect the loading of a pole. No banner or other appendage should be attached to an AAL pole unless approved by AAL. It the products are to be used on an existing foundation or on other structures, the customer assumes all responsibility for the structural integrity of the existing foundation, anchorage or structures and all the consequences arising 1herefrnm. CAUTION Poles should never be erected without the luminalre installed. Anchor bolts shall be hot dip galvanized steel, Six galvanized hex nuts and flat washers, and a bolt circle template shall be provided. Anchor bolts for poles 14 feet high or less are 3l4" x 24' x 3". Anchor bolt for poles more than 14 feet high are 1 "x 36" x 4". CERTIFICATION Certified UL 1598 in accordance with Article 410 of ANSI/NFPA 70, National Electrical Code. JOB TYPE NOTES 1 1 1 D132 -Decorative Pole 5" ROUND (RD) & FLUTED (FL) DECORATIVE BASE DIMENSIONS s- �OD POLE St' ANCHOR 101T PROJECTION j 1 4" GROUT UN©ER� ENTIRE BASE GONGiiEiEH]OTING BYOTHERS BOLT CIRC- E.1s" Di ACCESS 12WAPAR7 COVER I BOTTOM VIEW (INDICATES POLE IS LAYING DOWN WETH ACCESS COVER FACING UP) CACCESS COVER SINGLE FIXTURE MOUNTING ORIENTATION BOTTOM VIEW (INDICATES POLE is LAYING DOWN WITH ACCESS COVER FACING UP) ACCESS COVER I > � 1 � DOUBLE FIXTURE MOUNTING ORIENTATION BOTTOM VIEW (INDICATES POLE IS LAYING DOWN WITH ACCESS COVER FACING UP) 18.7" LIGHT POLE NOTES A. CODES. ALL ELECTRICAL WORK SHALL COMPLY WITH THE A DRAWINGS AND SPECIFICATIONS, THE NATIONAL ELECTRICAL CODE AND APPLICABLE LOCAL CODES, WHICHEVER IS MORE STRINGENT. B. CONDUCTORS. ALL CONDUCTORS ARE TO BE SOLID '^ COPPER THWN UNLESS OTHERWISE SHOWN OR REQUIRED BY CODE. C. RACEWAYS. RIGID GALV. CONDUIT IS TO BE USED WHERE SUBJECT TO PHYSICAL DAMAGE AND WHERE 18" COVER ROUND FLUTED CANNOT BE OBTAINED. PVC SCH 40 IS TO BE USED ALUMINUM POLE ELSEWHERE. ALL CONDUIT UNDER DRIVING SURFACES MUST HAVE A MINIMUM OF 24" OF COVER MATERIAL. D. SHOP DRAWINGS. SHOP DRAWINGS SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL FOR ALL ELECTRICAL MATERIALS. 41„ y E. SCALES. DO NOT SCALE OR TAKE DIMENSIONS FROM ELECTRICAL DRAWINGS. F. UNDERGROUND WORK. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DETERMINING THE EXACT ROUTES OF ALL UNDERGROUND WORK. ROUTES SHOWN ARE APPROXIMATE. POWER, TELEPHONE, CABLE COMPANIES AND ALL OTHER UTILITY COMPANIES SHALL BE CONSULTED, AND LINES SHALL BE STAKED. G. LIGHTING POLE. THE MANUFACTURER IS TO PROVIDE CERTIFICATION BY FLORIDA PE, SHOWING WIND LOAD RATING OF 170 MPH WITH SPECIFIED FIXTURES INSTALLED. THE FINAL POLE SET IS TO BE DETERMINED BY THE PROFESSIONAL ENGINEER. TPULLBOX AT EACH POLE \\#8 (CU) GND. d. •yi -1IMI1-_1I z ° I I t- III-IIr _ �-III=III-III I I I III -III o v, ° °, o .•...: °.. �'�' •l>a� � �=III=III=1 � III- � � � I=i _ - - I -III-, �- I CONDUIT y ••vi ;. v ••vi ''I-III-T- f y _ •7/-;. d vi > . °. r�. ; .•� ..°. � . GROUND ROD 5 . 12'x5/8' v vi COPPER CLAD -RUN #8 V. •• r TO LIGHTS) d • •vi ;. v � vi 3000 PSI CONCRETE °'.'. V. ° #2 BAR SPIRAL AT 12" PITCH 2'-0" 10' LIGHT POLE DETAIL NOT TO SCALE roKnow what's below. Call before you dig. LAKE EX L EX LT EX LT EX LT �_A EX LT DEER MOSS OVERALL SITE LIGHTING PLAN L• 1 0' APPROXIMATE SCALE: 1" = 60' CONTRACTOR IS TO PROVIDE FULL LOCATION SERVICE FOR ALL UNDERGROUND UTILITIES IN THE AREA OF CONSTRUCTION. Know what's below. Call before you dig aa CFIRoinFIL EnainEERInG RSSOCIRTES Inc, 575 NW MERCANTILE PL SUITE 106 PORT ST. LUCIE FL 34986 T.561.746.6343 F.561.746.3602 info@CEAengineers.com CA LIC. 31555 J 10APIrg- HARBOUR RIDUE TAG HT ii GilL1N7WY 0LU 8 PROPOSED STREET LIGHTING FOR DEER MOSS, TALLOWWOOD & WEST HAMMOCK VILLAGE PALM CITY, FL (D 2020 CARDINAL ENGINEERING ASSOCIATES, INC. THIS DOCUMENT, SHEET NO. HAS BEEN PREPARED SPECIFICALLY FOR THIS PROJECT. THIS DOCUMENT IS NOT SUITABLE FOR USE ON OTHER PROJECTS OR IN OTHER LOCATIONS WITHOUT THE APPROVAL AND PARTICIPATION OF CARDINAL ENGINEERING ASSOCIATES. UNAUTHORIZED REPRODUCTION AND/OR REUSE IS PROHIBITED. SHEET TITLE: DEER MOSS SITE LIGHTING PLAN REVISIONS: DESIGN BY: DATE: DJL 01/28/2020 DRAWN BY: CHECKED: NL JL E-01 OF 8 ELECTRICAL SHEETS 0 in LO 0 I O N O N c 0 rn N v MATCHLINE EX LT EX LT EX LT EXISTING PANELBOARD SCHEDULE 'A' (DEER MOSS) VOLTAMPS LOAD DESCRIPTION WIRES AWG POLES AMPS tot Y BUS A B 4h Y AMPS POLES LOAD DESCRIPTION WIRES AWG VOLTAMPS A� B� A0 B0 BACK FED MAIN BREAKER 6 2 60 1 2 20 EXISTING ACCENT LIGHTING EX 150 3 4 20 2 NEW STREET LIGHTS 12 72 5 6 ILI, 7 72 7 8 TOTAL CONNECTED VA VA TOTAL CONNECTED AMPS 222 72 TOTAL DEMAND VA 222 72 TOTAL DEMAND AMPS SUB -TOTAL VA SUB -TOTAL 2 1 PANELBOARD RATINGS PANELBOARD FEATURES VOLTAGE ❑ 120/208 1 0,3W ■ 120/240 1 0,3W ❑ BUS AMPS 0 100A ❑ 400A ❑ 200A ❑ 600A ❑ 225A ❑ ___A MAIN DEVICE ❑ MAIN LUGS ONLY ■ 60A CIRCUIT BREAKER ❑ ____A FUSED SWITCH ENCLOSURE ❑ FLUSH ■ SURFACE ENEMA 3R ■ HINGED DOOR [--]KEYED LATCH ❑ DOOR -IN -DOOR ❑ STAINLESS STEEL ■ PAINTED STEEL ■ NAMEPLATE BRANCH ❑ 12 ❑ 18 ❑ 24 POLES ❑ 36 ❑ 42 08 BRANCH DEVICES E CIRCUIT BREAKERS ❑ FUSES ❑ ----TO BE GFCI BREAKERS ❑ LOAD CENTER PERMITTED INTERRUPTING RATING (AIC SYM) ❑ 10,000A ❑ 30,000A ❑ 65,000A ❑ 14,000A ❑ 42,000A ❑ 100,000A ■ 22,000A ❑ 50,000A ❑ __ 000A [-]SERIES RATING PERMITTED ❑ SERVICE ENTRANCE RATED O1 O2 03 5 NOTES NEUTRAL BUS ❑ 50% ❑ 200% ■ 100% ❑ ---% BUS MATERIAL E COPPER [-]ALUMINUM E GROUND BUS REQUIRED ❑ -------PANELS IN PARALLEL ❑ THROUGH FEED LUGS REQUIRED dui / 1`I I MATCHLINE ----------------- NEW PHOTOCELL FOR POLE LIGHTS EXISTING FPL PAD EXISTING MOUNT TRANSFORMER METER EXISTING PHOTOCELL 120/240V, 1 �, 3W 1 r 7 A — —�— — II 1 1 1 I�EXISTING 60A MAIN BREAKER 1 1 I I I SITE LIGHTING PANEL 'A' 1 1 WITH 1 EXISTING 20A, 1P T BRANCH BREAKER FEEDING 1 1 ENTRANCE UP LIGHTS. ADD 1 1 1 1 20/2 FOR NEW POLE i I 1 1 LIGHTING I I 1 ---J I MATCHLINE �---fir 1 "-3#6 3/4"-2#12+12G TO NEW POLE LIGHTS ELECTRICAL RISER DIAGRAM SOURCE=120/24OV, 1�, 3W EXISTING WORK SHOWN DASHED DEMO WORK SHOWN BOLD FIRE HYDRA DEER MOSS ENLARGED SITE LIGHTING PLAN APPROXIMATE SCALE: 1" = 30' KEYED NOTES O O1 NEW LIGHT POLE ON PRECAST BASE. SEE LIGHT POLE DETAIL. VERIFY EXACT PLACEMENT IN FIELD WITH OWNER. O2 NEW BURIED LIGHTING CIRCUIT. 3/4"-SCH40 PVC WITH 2#12+12G THWN-2. MAINTAIN 24" MINIMUM COVER. O TRENCH ACROSS EXISTING DRIVEWAY. REMOVE AND REPLACE PAVERS AND SUB BASE MATERIAL. REPAIR DRIVEWAY PAVER FINISH TO MATCH CONDITION THAT EXISTS BEFORE THIS PROJECT. O EXISTING FPL METER. O EXISTING SITE LIGHTING PANEL 'A' WITH NEW 20/2 BRANCH BREAKER FOR NEW POLE LIGHTS. O PROVIDE PULL BOXES AND SPLICE BOXES AS REQUIRED BASED ON SITE CONDITIONS. MATCHLINE CONTRACTOR IS TO PROVIDE FULL LOCATION SERVICE FOR ALL UNDERGROUND UTILITIES IN THE AREA OF CONSTRUCTION. Know what's below. Call before you dig aa CF1RDinFIL EncinEERInc RSSOCIRTES Inc. 575 NW MERCANTILE PL SUITE 106 PORT ST. LUCIE FL 34986 T.561.746.6343 F.561.746.3602 info@CEAengineers.com CA LIC. 31555 VA111111111-- HARBOUR 1111DUE TAU MY & 04LINTRY 0LII 9 PROPOSED STREET LIGHTING FOR DEER MOSS, TALLOWWOOD & WEST HAMMOCK VILLAGE PALM CITY, FL © 2020 CARDINAL ENGINEERING ASSOCIATES, INC. THIS DOCUMENT, SHEET NO. HAS BEEN PREPARED SPECIFICALLY FOR THIS PROJECT. THIS DOCUMENT IS NOT SUITABLE FOR USE ON OTHER PROJECTS OR IN OTHER LOCATIONS WITHOUT THE APPROVAL AND PARTICIPATION OF CARDINAL ENGINEERING ASSOCIATES. UNAUTHORIZED REPRODUCTION AND/OR LREUSE IS PROHIBITED. SHEET TITLE: DEER MOSS ENLARGED SITE LIGHTING PLAN REVISIONS: DESIGN BY: DATE: DJL 01/28/2020 DRAWN BY: CHECKED: NIL JL E-02 OF 8 ELECTRICAL SHEETS Submitted by SEFL, Inc. Catalog Number: Type: Job Name: PROV-T3-32LED-4K-700-DB-DF �.�.L Harbour Ridge STND_MNT-AD5-WIRED120-277V 7 Notes: SEFL INC.18-22975 Providence®MicroCoreTM - Medium Housing PROV I TYPE FEATURES • Reliable, uniform, glare free illumination • 0-1OV dimming ready • 14 standard powder coat finishes • Types II, III, IV, V and custom • Integral surge suppression distributions' • UfeShieldTM thermal protection • 3000K, 4000K, 5000K CCT SPECIFICATIONS'/ • Diameter: 18.7" / 475 mm • Height: 31.5" / 800 mm • Weight: 29lbs • EPA: 0.96 • I Rating: 65 ORDERING INFORMATION MODEL 1 2 PROV Light Engine CCT Dri 1. LIGHT ENGINE T2 Type /l T3 Type NI T4 Type IV T5 Type V 2. COLOR TEMPERATURE 32LED -3K 3000KCCT 70CR1 32LED-4K 4000KCCT,70CRI 32LED-5K 5000KCCT 70CR1 Additional CCT's and 560nm monochromatic amber available by request' 3. DRIVE CURRENT 700 700mA, 75 watts 450 450mA, 48 watts 4. FINISH Standard Color AGN Antique Green BL Black BLT Matte Black CRT Corten DB Dark Bronze DGN Dark Green LG Light Grey MAL Matte Aluminum MDB Bronze Metallic MG Medium Grey TT Titanium VBU Verde Blue WDB Weathered Bronze WH Arctic White �TERTfk CC �US I TPPROVFp -s,Eo 3000K and warmer CCTs only 3 4 5 ve Current Finish Options 4. FINISH (CONT) Premium Color SFM Sealoam SHK Shamrock SPP Salt and Pepper WCP Weathered Copper RAL RAL 4 digit Color CUSTOM Custom Color 5. OPTIONS (maychoose as noted) Fuse may choose one DF 208 or 240 Line Volts Finish SPK Decorative spike BPS Struts painted brass PFN Finial painted brass Optics may choose one LDL Lightydiffused lens CLR Clear flat lens HSS House Side shield for Type 4 Accessories may choose one EPA-C Egress -Contemporary' EPA T Egress -Traditional' Mounting may choose one PT23 Slips Over a 2 3/8"x 4" Tenon PT3 Slips Over a 3'x 4" Tenon 6.CONTROL PCA-C Rotatable photocell -Contemporary PCA-T Rotatable photocell -Traditional SOP Sensor Control Programmable, pole ARCHITECTURAL AREA LIGHTING ,JOB architectural 17760 Rowland Street I City of Industry I CA 91748 TYPE arealighting P626.968.5666 i F626.369.2695 I www.aal.net NOTES Copyright 0 2014 February 15, 2018 8:36 AM 6 7 Mounting Controls 7. MOUNTING Standard configuration slips over a 4° DIA open top pole or may choose one. Wall Mount Arm WMA7 WMA57 WMA35U WMA55 WMA91J WMA36U WMA56 WMA22U Pole Mount Arm TRA51J-4 TRA5U-5 TRA6U-4 TRAISU-5 TRA55-4 TRA55-5 TRA57-4 TRA57-5 TRA56 SLA1 SLA1-2 SLA8U-4 SLA81J-5 SLA221J-4 SLA221J-5 Pier Mount PM1 PM2 PM3 Option AD5 NOTE: ' Pole accessory with motion sensor and daylight photo - control for California Tite 24 section 130.2 compliance For complete spec sheet and ordering information, visit www.aalnet/producWsensor control programmable/ 2 Handheld commissioning tool is required to separately configure or adjust any number of SCP sensors 3 Not compatible with PCA-C nor PCA-T DB2 5R12-188 12(3.7m) 5" RD x .188" 116 32.3 28.5 22.7 18.6 15.5 13.1 11.2 9.6 DB2 5R14-188 14' (4.3m) 5" RD x .188" 116 32.3 28.5 22.7 18.6 15.5 13.1 11.2 9.6 DB2 5R16-188 16' (4.9m) 5" RD x .188" 123 27.3 23.9 19.0 15.5 12.8 10.8 9.2 7.9 DB2 5R18-188 18' (5.5m) 5" RD x .188" 129 22.8 19.8 15.6 12.7 10.5 8.8 7.4 6.4 DB2 5R20-188 20' (6.2m) 5" RD x .188" 136 18.9 16.4 12.8 10.3 8.5 7.0 5.9 5.0 DB2 5R22-188 22' (6.8m) 5" RD x .188" 142 15.8 13.5 10.4 8.3 6.8 5.6 4.7 3.9 DB2 5R24-188 24' (7.4m) 5" RD x .188" 148 13.1 11.1 8.4 6.6 5.3 4.3 3.6 3.0 DB2 5R25-188 25' (7.7m) 5" RD x .188" 151 11.9 10.0 7.5 5.9 4.7 3.8 3.1 2.5 D62 5R14-250 14' (4.3m) 5" RD x .250" 132 35.7 31.5 25.2 20.6 17.2 14.5 12.4 10.7 DB2 5R16-250 16' (4.9m) 5" RD x .250" 140 30.5 26.8 21.3 17.4 14.5 12.2 10.4 9.0 DB2 5R18-250 18' (5.5m) 5" RD x .250" 150 25.8 22.5 17.8 14.5 12.0 10.1 8.6 7.3 DB2 5R20-250 20' (6.2m) 5" RD x .250" 158 21.8 18.9 14.8 12.0 9.9 8.3 7.0 6.0 DB2 5R22-250 22' (6.8m) 5" RD x .250" 167 18.5 15.9 12.4 9.9 8.1 6.7 5.7 4.8 DB2 5R24-250 24' (7.4m) 5" RD x .250" 176 15.7 13.4 10.3 8.2 6.6 5.5 4.5 3.8 D62 5R25-250 25' (7.7m) 5" RD x .250" 180 14.5 12.3 9.3 7.4 6.0 4.9 4.0 3.4 DB2 5F14-188 14' (4.3m) 5" FL x .188" 116 21.4 18.7 14.8 12.1 10.0 8.2 6.9 5.8 DB2 51`16-188 16' (4.9m) 5" FL x .188" 123 17.8 15.5 12.1 9.8 8.0 6.6 5.4 4.5 D62 51`18-188 18' (5.5m) 5" FL x .188" 129 14.5 12.5 9.7 7.8 6.3 5.1 4.1 3.3 DB2 51`20-188 20' (6.2m) 5" FL x .188" 136 11.8 10.0 7.6 6.1 4.8 3.7 3.0 2.3 DB2 5F22-188 22' (6.8m) 5" FL x .188" 142 9.4 7.9 5.8 4.6 3.9 2.6 2.0 1.4 DB2 5F24-188 24' (7.4m) 5" FL x .188" 148 7.4 6.1 4.3 3.3 2.4 1.7 1.1 0.6 DB2 5F25-188 25' (7.7m) 5" FL x .188" 151 6.6 5.2 3.6 2.7 1.9 1.2 0.7 0.3 Nolo- Overall height is measured to top of pole. 2. COLOR Standard Color 3. OPTIONS / ACCESSORIES W H Arctic White AD5 (This adapter is to be used only with standard AAL arms BL Black and post top mount fa9ures that slip over 4" od pole. The ELT Matte Black AD5 is a cast aluminum adapter that slips into the arm or over DB Dark Bronze 5"/125mmO.D. pole.) DGN Dark Green FH(Flag holder. Spedlocation on pole) TT Titanium FS1 (Single weatherproofluseholder Fusebyothers.) W DB Weathered Bronze FS2 (Double weatherproof fuse holder. Fuse by others) MOB Bronze Metallic PC R (Low profile twist lock photocell receptacle with castpole V BU Verde Blue cap top. Secures to the top of the pole with three stainless steel CRT Corten set screws. Photocell by others.) MAL Mate Aluminum R BC (Cast aluminum receptacle housing, integrally welded to M G Medium Grey the pole. Includes a NEC approved clear weatherproolcover. Does not include a receptacle or internal wiring.) AGN Antique Green LG Light Grey Premium Color SHK Shamrock SPP SaitandPepper SFM Sealoam WCP Weathered Copper RAL RAL4digit Color CUSTOM Custom Color ARCHITECTURAL AREA LIGHTING 16555 East Gale Ave. I City of Industry I CA 91745 P 626.968.5666 1 F 626.369.2695 1 www.aal.net Copyright© 2012 1 REV 6.12 Type: SEFL INC.18-22975 DB2 - Decorative Pole DB2 Job Name: �Harboul­Ridge EFL - - ,S'ou/�eusG FYatu4c �w�y D132 - Decorative Pole TYPE 5" ROUND (RD) & FLUTED (FL) DECORATIVE BASE Catalog Number: DB25F12-188-PTF-DB-ABT Notes Pole height 12' ■ 1. BASE 2. POLE 3, OAH 4. COLOR 5. OPTIONS/ACCESSORIES 5" ROUND (RD) & FLUTED (FL) DECORATIVE BASE MAXIMUM ALLOWABLE EPA (MPH) i PAS.F 9 Pnl F 'Aneu suer-r WT as on inn 11A ion ian lAn un I SPECIFICATIONS DIMENSIONS a O.D. POLE Base shall be cast aluminum #356 alloy, free of any porosity, foreign materials, or cosmetic fillers. Base casting shall be heat treated to a T-6 condition, and of uniform wall thickness, with no warping or mold shifting. WARNINGS Caution must be exercised in the selection of a design wind speed when the pole is to be installed in a special wind region (as indicated by the wind map) or in an area where wind speed is unpredictable. AAL recommends consulting a local engineer when the pole is to be installed in an area that may be subject to extreme weather and exposure. Poles installed on structures such as buildings and bridges may be subjected to vibration, oscillations, and other fatigue effects which are not covered by the AAL warranty.The use of banners or other appendages can severely affect the loading of a pole. No banner or other appendage should be attached to an AAL pole unless approved by AAL. If the products are to be used on an existing foundation or on other structures, the customer assumes all responsibility for the structural integrity of the existing foundation, anchorage or structures and all the consequences arising therefrom. CAUTION Poles should never be erected without the luminaire installed. Anchor bolts shall be hot dip galvanized steel. Six galvanized hex nuts and flat washers, and a bolt circle template shall be provided. Anchor bolts for poles 14 feet high or less are 3/4" x 24" x 3". Anchor bolt for poles more than 14 feet high are 1 "x 36" x 4". CERTIFICATION Certified UL 1598 in accordance with Article 410 of ANSI/NFPA 70, National Electrical Code. JOB TYPE NOTES I _TOAH p n p II II II sr, ANCHOR BOLT PgOJECTION a LU UJ GROUT UNDER CONCRETE FOOTING ENTIRE BASE BV OTHERS BOLT CIRCLE: 16"DIA. ACCESS 120°APART COVER 20° DIA BOTTOM VIEW (INDICATES POLE IS LAYING DOWN WITH ACCESS COVER FACING UP) ACCESS COVER 1 SINGLE FIXTURE MOUNTING ORIENTATION BOTTOM VIEW (INDICATES POLE IS LAYING DOWN WITH ACCESS COVER FACING UP) ACCESS COVER 1 -- DOUBLE FIXTURE MOUNTING ORIENTATION BOTTOM VIEW (INDICATES POLE IS LAYING DOWN WITH ACCESS COVER FACING UP) 18.7" Ilk LIGHT POLE NOTES A. CODES. ALL ELECTRICAL WORK SHALL COMPLY WITH THE ��� DRAWINGS AND SPECIFICATIONS, THE NATIONAL ELECTRICAL CODE AND APPLICABLE LOCAL CODES, WHICHEVER IS MORE STRINGENT. O LIGHT FIXTURE B � B. CONDUCTORS. ALL CONDUCTORS ARE TO BE SOLID M COPPER THWN UNLESS OTHERWISE SHOWN OR REQUIRED BY CODE. C. RACEWAYS. RIGID GALV. CONDUIT IS TO BE USED WHERE SUBJECT TO PHYSICAL DAMAGE AND WHERE 18" COVER ROUND FLUTED CANNOT BE OBTAINED. PVC SCH 40 IS TO BE USED ALUMINUM POLE ELSEWHERE. ALL CONDUIT UNDER DRIVING SURFACES MUST HAVE A MINIMUM OF 24" OF COVER MATERIAL. D. SHOP DRAWINGS. SHOP DRAWINGS SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL FOR ALL ELECTRICAL MATERIALS. 4J" E. SCALES. DO NOT SCALE OR TAKE DIMENSIONS FROM ELECTRICAL DRAWINGS. F. UNDERGROUND WORK. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DETERMINING THE EXACT ROUTES OF N ALL UNDERGROUND WORK. ROUTES SHOWN ARE APPROXIMATE. POWER, TELEPHONE, CABLE COMPANIES AND ALL OTHER UTILITY COMPANIES SHALL BE CONSULTED, AND LINES SHALL BE STAKED. G. LIGHTING POLE. THE MANUFACTURER IS TO PROVIDE WP/GFI DUPLEX CERTIFICATION BY FLORIDA PE, SHOWING WIND LOAD RECEPTACLE 0 RATING OF 170 MPH WITH SPECIFIED FIXTURES INSTALLED. THE FINAL POLE SET IS TO BE DETERMINED BY THE HAND HOLE PROFESSIONAL ENGINEER. PULLBOX AT EACH POLE #8 (CU) GND. GROUND _ _ _ _ � 17 r III -II II1=1II-II1=_I I' - III -III III - -III -I 1 I-1 I I -III III � -III -I I I -I 11=1 I F =1 I I -III -III -III -III -III -III -I I T:r :;-' '-III-III-III-III-III-III-III 111,11,111E111E111E111=111-11 ° �.� a: =1 11=1 I 1=11 Z I I -I 111E1I11=1117 o o, a. o .o, I _I 11-111-111-11M I I : ,� : , ..:. ,� .,.. J 1-111-1 11-1 I II I -111=1 I F1111=111=1 I M 1 ..1. o.:. 111E1 I M 111-1 I I 1=1 11=1 1=1 I I I M I I CNI 11-111E1 I M I I I I I 1 111=1 I I -I v v� v yr -111E111-11 ;'.' •' '. ' ;'•' ' ,. 111E111-111 1 - a 11=111- III -I �'� �'� I� fay I M I M I M1 I -111- I 111-1' _ - -III-III-, i- CONDUIT ..vi . d _ .7/. III-� r� . �. GROUND ROD 12'x5/8" v .. I v : p.'vj COPPER CLAD -RUN #8 ;. y vi; v •vi TO LIGHTS) d vi ;. v vi 3000 PSI r. CONCRETE Know what's below. #2 BAR SPIRAL Call before you dig. AT 12" PITCH 2'-0" 12' LIGHT POLE DETAIL PROPOSED LIGHT POLE EXISTING PAD MOUNT XFMR W/PANEL EXISTING TRANFORMER W/PANEL Nw HgRe FLEX LT �R R� \ EXISTING PAD MOUNT XFMR TALLOWOOD VILLAGE C'Tr]rU T 1rf__1ur1rTNT1DT ANT EXISTING PAD MOUNT 9XFMR -- EX LT EX TEL DEER MOSS VILLAGE CONTRACTOR IS TO PROVIDE FULL LOCATION SERVICE FOR ALL UNDERGROUND UTILITIES IN THE AREA OF CONSTRUCTION. Know what's b@IOW. Call before you dig aa CFIRi3inF1L Er1GIr1EERnG RSSOCIRTES Inc. 575 NW MERCANTILE PL SUITE 106 PORT ST. LUCIE FL 34986 T.561.746.6343 F.561.746.3602 info@CEAengineers.com CA LIC. 31555 J IOAPF9- HAREILIUR FRI01iE TAG HT fi Gil lu R1` 0LU 8 PROPOSED STREET LIGHTING FOR DEER MOSS, TALLOWWOOD & WEST HAMMOCK VILLAGE PALM CITY, FL JOSEPH L. LAMMERS ,PE PE # 78477 SEAL , © 2020 CARDINAL ENGINEERING ASSOCIATES, INC. THIS DOCUMENT, SHEET NO. HAS BEEN PREPARED SPECIFICALLY FOR THIS PROJECT. THIS DOCUMENT IS NOT SUITABLE FOR USE ON OTHER PROJECTS OR IN OTHER LOCATIONS WITHOUT THE APPROVAL AND PARTICIPATION OF CARDINAL ENGINEERING ASSOCIATES. UNAUTHORIZED REPRODUCTION AND/OR LREUSE IS PROHIBITED. SHEET TITLE: TALLOWOOD SITE LIGHTING PLAN REVISIONS: DESIGN BY: DATE: DJL 01/28/2020 DRAWN BY: CHECKED: NL JL E-03 NOT TO SCALE OF 8 ELECTRICAL SHEETS 0 Ib LO 0 I O N O N c 0 0) N i 1 FIRE HYDRANT • ` MATCHLINE SEE E-04 ------------------ MATCHLINE SEE E-05 i ------\N7---- EXISTING FPL PAD MOUNT TRANSFORMER 120/240V, 1 3W I I I I I I NEW PHOTOCELL FOR POLE LIGHTS EXISTING METER EXISTING PHOTOCELL B (1 I I~EXISTING 60A MAIN BREAKER El SITE LIGHTING PANEL 'B' WITH 1 EXISTING 20A, 1 P L_ T BRANCH BREAKER FEEDING ENTRANCE UP LIGHTS. ADD 20/2 FOR NEW POLE I LIGHTING 3/4"-2#12+12G 1 "-3#6 ELECTRICAL RISER DIAGRAM SOURCE= 1 20/24OV, 1 �, 3W EXISTING WORK SHOWN DASHED BOR e0\V'�RD TO NEW POLE LIGHTS EXISTING PANLLBOARD SCHEDULE 'B' (TALLOwoOv) VOLTAMPS LOAD DESCRIPTION WIRES qWG POLES AMPS �BUS A B Y U AMPS POLES LOAD DESCRIPTIONqWG WIRES VOLTAMPS A� B� A0 60 BACK FED MAIN BREAKER 2 60 1 2 20 1 EXISTING ACCENT LIGHTING EX 150 3 4 20 2 NEW STREET LIGHTS 12 110 jj 5 6 110 7 8 TOTAL CONNECTED VA VA TOTAL CONNECTED AMPS 260 110 TOTAL DEMAND VA 260 110 TOTAL DEMAND AMPS SUB -TOTAL VA SUB -TOTAL 2 1 PANELBOARD RATINGS PANELBOARD FEATURES VOLTAGE ❑ 120/208 1 0,3W 120/240 1 0,3W ❑ BUS AMPS M100A ❑ 400A ❑ 200A ❑ 600A ❑ 225A ❑ ___A MAIN DEVICE [-]MAIN LUGS ONLY ■ 60A CIRCUIT BREAKER ❑ ____A FUSED SWITCH ENCLOSURE ❑ FLUSH NSURFACE ■ NEMA 3R ■ HINGED DOOR [--]KEYED LATCH ❑ DOOR -IN -DOOR ❑ STAINLESS STEEL EPAINTED STEEL ■ NAMEPLATE BRANCH ❑ 12 ❑ 18 ❑ 24 POLES ❑ 36 ❑ 42 ■ 8 BRANCH DEVICES MCIRCUIT BREAKERS [:]FUSES ❑ ----TO BE GFCI BREAKERS [--]LOAD CENTER PERMITTED INTERRUPTING RATING (AIC SYM) ❑ 10,000A ❑ 30,000A ❑ 65,000A ❑ 14,000A ❑ 42,000A ❑ 100,000A ■ 22,000A ❑ 50,000A ❑ __ 000A ❑ SERIES RATING PERMITTED ❑ SERVICE ENTRANCE RATED Q1 O2 �3 NOTES NEUTRAL BUS ❑ 50% ❑ 200% ■ 100% ❑ ---% BUS MATERIAL E COPPER [-]ALUMINUM EGROUND BUS REQUIRED ❑ -------PANELS IN PARALLEL ❑ THROUGH FEED LUGS REQUIRED MATCHLINE SEE E-04 ------------ MATCHLINE SEE E-05 TALLOWOOD VILLAGE ENLARGED SITE LIGHTING PLAN APPROXIMATE SCALE: 1" = 30' KEYED NOTES (X) R NEW LIGHT POLE ON PRECAST BASE. SEE LIGHT POLE DETAIL. VERIFY EXACT PLACEMENT IN FIELD WITH OWNER. R2 NEW BURIED LIGHTING CIRCUIT. 3/4"-SCH40 PVC WITH 2#12+12G THWN-2. MAINTAIN 24" MINIMUM COVER. O TRENCH ACROSS EXISTING DRIVEWAY. REMOVE AND REPLACE PAVERS AND SUB BASE MATERIAL. REPAIR DRIVEWAY PAVER FINISH TO MATCH CONDITION THAT EXISTS BEFORE THIS PROJECT. O EXISTING FPL METER. O EXISTING SITE LIGHTING PANEL 'B' WITH NEW 20/2 BRANCH BREAKER FOR NEW POLE LIGHTS. O PROVIDE PULL BOXES AND SPLICE BOXES AS REQUIRED BASED ON SITE CONDITIONS. CONTRACTOR IS TO PROVIDE FULL LOCATION SERVICE FOR ALL UNDERGROUND UTILITIES IN THE AREA OF CONSTRUCTION. Know what's below. Call before you dig aa CARDinRL EnGInEERInG RSSOCIRTES Inc. 575 NW MERCANTILE PL SUITE 106 PORT ST. LUCIE FL 34986 T.561.746 ' 6343 F.561.746.3602 info@CEAengineers.com CA LIC. 31555 VA111111111-- HAM190UP 1111DEE TAU MY & 04LINTRY 0LII 9 PROPOSED STREET LIGHTING FOR DEER MOSS, TALLOWWOOD & WEST HAMMOCK VILLAGE PALM CITY, FL © 2020 CARDINAL ENGINEERING ASSOCIATES, INC. THIS DOCUMENT, SHEET NO. HAS BEEN PREPARED SPECIFICALLY FOR THIS PROJECT. THIS DOCUMENT IS NOT SUITABLE FOR USE ON OTHER PROJECTS OR IN OTHER LOCATIONS WITHOUT THE APPROVAL AND PARTICIPATION OF CARDINAL ENGINEERING ASSOCIATES. UNAUTHORIZED REPRODUCTION AND/OR LREUSE IS PROHIBITED. SHEET TITLE: TALLOWOOD ENLARGED SITE LIGHTING PLAN REVISIONS: DESIGN BY: DATE: I DJL 01/28/2020 DRAWN BY: CHECKED: NIL JL E-04 OF 8 ELECTRICAL SHEETS 0 00 LO 0 I O N O N c 0) N MATCHLINE SEE E-04 ----------------------------------- MATCHLINE SEE E-05 NEW PHOTOCELL FOR POLE LIGHTS EXISTING FPL PAD EXISTING MOUNT TRANSFORMER 120/240V, 1 �, 3W METER Y_EXISTING PHOTOCELL C I- EXISTING 60A MAIN BREAKER ❑ SITE LIGHTING PANEL 'C' L WITH 1 EXISTING 20A, 1P T _ BRANCH BREAKER FEEDING I I I ENTRANCE UP LIGHTS. ADD 20/2 FOR NEW POLE LIGHTING I I I 3/4"-2#12+12G L------J I TO NEW POLE LIGHTS SUB -TOTAL VA ELECTRICAL RISER DIAGRAM SOURCE=120/24OV, 1 �, 3W EXISTING WORK SHOWN DASHED EXISTING PANLLBOARD SCHEDULE U (TALLOWOOD) TOTAL CONNECTED AMPS TOTAL DEMAND AMPS SUB -TOTAL VA PANELBOARD RATINGS PANELBOARD FEATURES VOLTAGE ❑ 120/208 1 0,3W ■ 120/240 1 0,3W ❑ BUS AMPS E 100A ❑ 400A ❑ 200A ❑ 600A ❑ 225A ❑ ___A MAIN DEVICE [-]MAIN LUGS ONLY ■ 60A CIRCUIT BREAKER ❑ __A FUSED SWITCH ENCLOSURE ❑ FLUSH ■ SURFACE ENEMA 3R ■ HINGED DOOR ❑ KEYED LATCH ❑ DOOR -IN -DOOR []STAINLESS STEEL E PAINTED STEEL 0 NAMEPLATE BRANCH ❑ 12 ❑ 18 ❑ 24 POLES ❑ 36 ❑ 42 08 BRANCH DEVICES E CIRCUIT BREAKERS ❑ FUSES ❑ ----TO BE GFCI BREAKERS ❑ LOAD CENTER PERMITTED INTERRUPTING RATING (AIC SYM) ❑ 10,000A ❑ 30,000A ❑ 65,000A ❑ 14,000A ❑ 42,000A ❑ 100,000A ■ 22,000A ❑ 50,000A ❑--,000A ❑ SERIES RATING PERMITTED [-]SERVICE ENTRANCE RATED Ol O2 O3 NOTES NEUTRAL BUS ❑ 50% ❑ 200% ■ 100% ❑ ---% BUS MATERIAL E COPPER ❑ ALUMINUM E GROUND BUS REQUIRED ❑ _______PANELS IN PARALLEL ❑ THROUGH FEED LUGS REQUIRED MATCHLII ----------------- MATCHLV TALLOWOOD VILLAGE ENLARGED SITE LIGHTING PLAN APPROXIMATE SCALE: 1" = 30' KEYED NOTES X ) NEW LIGHT POLE ON PRECAST BASE. SEE LIGHT POLE DETAIL. VERIFY EXACT PLACEMENT IN FIELD WITH OWNER. NEW BURIED LIGHTING CIRCUIT. 3/4"-SCH40 PVC WITH 2#12+12G THWN-2. MAINTAIN 24" MINIMUM COVER. TRENCH ACROSS EXISTING DRIVEWAY. REMOVE AND REPLACE PAVERS AND SUB BASE MATERIAL. REPAIR DRIVEWAY PAVER FINISH TO MATCH CONDITION THAT EXISTS BEFORE THIS PROJECT. EXISTING FPL METER. EXISTING SITE LIGHTING PANEL 'C' WITH NEW 20/2 BRANCH BREAKER FOR NEW POLE LIGHTS. PROVIDE PULL BOXES AND SPLICE BOXES AS REQUIRED BASED ON SITE CONDITIONS. CONTRACTOR IS TO PROVIDE FULL LOCATION SERVICE FOR ALL UNDERGROUND UTILITIES IN THE AREA OF CONSTRUCTION. Know what's below. Call before you dig aa CF1RDinFIL EncinEERInc RSSOCIRTES Inc. 575 NW MERCANTILE PL SUITE 106 PORT ST. LUCIE FL 34986 T.561.746.6343 F.561.746.3602 info@CEAengineers.com CA LIC. 31555 VAIIIIIIIIII11-- HAM190UP 1111DEE TAU MY & 04LINTRY 0LII 9 PROPOSED STREET LIGHTING FOR DEER MOSS, TALLOWWOOD & WEST HAMMOCK VILLAGE PALM CITY, FL © 2020 CARDINAL ENGINEERING ASSOCIATES, INC. THIS DOCUMENT, SHEET NO. HAS BEEN PREPARED SPECIFICALLY FOR THIS PROJECT. THIS DOCUMENT IS NOT SUITABLE FOR USE ON OTHER PROJECTS OR IN OTHER LOCATIONS WITHOUT THE APPROVAL AND PARTICIPATION OF CARDINAL ENGINEERING ASSOCIATES. UNAUTHORIZED REPRODUCTION AND/OR LREUSE IS PROHIBITED. SHEET TITLE: TALLOWOOD ENLARGED SITE LIGHTING PLAN REVISIONS: DESIGN BY: DATE: DJL 01/28/2020 DRAWN aBYCJL HECKED: NL E-05 OF 8 ELECTRICAL SHEETS E 0 00 0 0 0 N O N C 0 O N a� EXISTING FPL PAD EXISTING MOUNT TRANSFORMER METER EXISTING PHOTOCELL 120/240V, 1�, 3W r- -1 r D I (1 I I ❑ I~EXISTING 100A MAIN BREAKER SITE LIGHTING PANEL 'D' WITH 1 EXISTING T T 20A, 1P BRANCH BREAKER I FEEDING ENTRANCE UP I LIGHTS AND 20/2 FOR REPLACEMENT POLE LIGHTING (�>-3/4"-2#12+12G L — — J I L TO REPLACEMENT -I- POLE LIGHTS ELECTRICAL RISER DIAGRAM SOURCE=120/24OV, 1 �, 3W EXISTING WORK SHOWN DASHED EXISTING PANELBOARD SCHEDULE 'D' (WEST HAMMOCK) VOLTAMPS LOAD DESCRIPTION WIRES q�yG POLES AMPS � Y U BUS A B tum Y U AMPS POLES LOAD DESCRIPTION WIRES gVyG VOLTAMPS A� B� A0 BO BACK FED MAIN BREAKER 00 1 2 20 2 STREET LIGHTS EX 15v 3 4 5 6 20 1 PHOTOCELL CONTROL EX 180 7 8 20 1 GFCI BREAKER EX 180 9 10 11 12 13 14 15 16 TOTAL CONNECTED VA VA TOTAL CONNECTED AMPSI 330 330 11 TOTAL DEMAND VA TOTAL DEMAND AMPS SUB -TOTAL 330 SUB -TOTAL 3 1 3 VA PANELBOARD RATINGS PANELBOARD FEATURES VOLTAGE ■ 120/208 10,3W ❑ 120/240 1 0,3W ❑ BUS AMPS ■ 100A ❑ 400A ❑ 200A ❑ 600A ❑ 225A ❑ ___A MAIN DEVICE [-]MAIN LUGS ONLY 0 100A CIRCUIT BREAKER ❑ ____A FUSED SWITCH ENCLOSURE ❑ FLUSH E SURFACE ENEMA 3R ■ HINGED DOOR ❑ KEYED LATCH ❑ DOOR -IN -DOOR ❑ STAINLESS STEEL ■ PAINTED STEEL 0 NAMEPLATE BRANCH ❑ 12 ❑ 18 ❑ 24 POLES ❑ 36 ❑ 42 N 16 BRANCH DEVICES ■ CIRCUIT BREAKERS ❑ FUSES ❑ ---- TO BE GFCI BREAKERS ❑ LOAD CENTER PERMITTED INTERRUPTING RATING (AIC SYM) ❑ 10,000A ❑ 30,000A ❑ 65,000A ❑ 14,000A ❑ 42,000A ❑ 100,000A 0 22,000A ❑ 50,000A ❑ __ 000A ❑ SERIES RATING PERMITTED [-]SERVICE ENTRANCE RATED 0 O2 O3 NOTES NEUTRAL BUS ❑ 50% ❑ 200% 100% ❑ ---% BUS MATERIAL ■ COPPER ❑ ALUMINUM NGROUND BUS REQUIRED ❑------- PANELS IN PARALLEL ❑ THROUGH FEED LUGS REQUIRED WEST HAMMOCK VILLAGE SITE LIGHTING PLAN APPROXIMATE SCALE: 1" = 60' CONTRACTOR IS TO PROVIDE FULL LOCATION SERVICE FOR ALL UNDERGROUND UTILITIES IN THE AREA OF CONSTRUCTION. Know what's b@IOW. Call before you dig Ca CIFIRoinFIL EncinEERm RSSOCIRTES Inc 575 NW MERCANTILE PL SUITE 106 PORT ST. LUCIE FL 34986 T.561.746.6343 F.561.746.3602 info@CEAengineers.com CA LIC. 31555 10JI111111irg- HAREILIUR FZ10UE TAG HT fi GilLIM7RY 0LLI8 PROPOSED STREET LIGHTING FOR DEER MOSS, TALLOWWOOD & WEST HAMMOCK VILLAGE PALM CITY, FL QC 2020 CARDINAL ENGINEERING ASSOCIATES, INC. THIS DOCUMENT, SHEET NO. HAS BEEN PREPARED SPECIFICALLY FOR THIS PROJECT. THIS DOCUMENT IS NOT SUITABLE FOR USE ON OTHER PROJECTS OR IN OTHER LOCATIONS WITHOUT THE APPROVAL AND PARTICIPATION OF CARDINAL ENGINEERING ASSOCIATES. UNAUTHORIZED REPRODUCTION AND/OR REUSE IS PROHIBITED. SHEET TITLE: WEST HAMMOCK SITE LIGHTING PLAN REVISIONS: DESIGN BY: DATE: DJL 01/28/2020 DRAWN BY: CHECKED: NL JL E-06 OF 8 ELECTRICAL SHEETS 0 00 Ln 0 I 0 N O N 0 rn N aD KEYED NOTES O O1 EXISTING STREET LIGHTING CIRCUIT TO BE RE —USED. O2 NEW POLE LIGHT AND BASE TO REPLACE EXISTING LIGHT AT SAME LOCATION. O3 EXISTING STREET LIGHTING HAND HOLE WITH EXISTING CIRCUITING TO BE RE —USED. PROVIDE NEW SPLICES AND NEW WIRING UP TO NEW FIXTURE. O4 EXISTING SITE LIGHTING PANEL D. USE EXISTING 20/2 BREAKER TO FEED NEW POLE LIGHTS IN EXISTING LOCATIONS. O5 EXISTING METER. O6 EXISTING PAD MOUNTED TRANSFORMER. MATCHLINE --------------- MATCHLINE ------------ WEST HAMMOCK VILLAGE ENLARGED SITE LIGHTING PLAN APPROXIMATE SCALE: 1" = 30' MATCHLINE -------------------------- CONTRACTOR IS TO PROVIDE FULL LOCATION SERVICE FOR ALL UNDERGROUND UTILITIES IN THE AREA OF CONSTRUCTION. Know what's b@IOW. Call before you dig aa CFIRi3inF1L EncinEERm RSSOCIRTES Inc 575 NW MERCANTILE PL SUITE 106 PORT ST. LUCIE FL 34986 T.561.746.6343 F.561.746.3602 info@CEAengineers.com CA LIC. 31555 1 10irg- HAREILIUR FRI01iE TAG HT fi GilLIM7RY 0LLI8 PROPOSED STREET LIGHTING FOR DEER MOSS, TALLOWWOOD & WEST HAMMOCK VILLAGE PALM CITY, FL JOSEPH L. LAMMERS ,PE PE # 78477 SEAL , QC 2020 CARDINAL ENGINEERING ASSOCIATES, INC. THIS DOCUMENT, SHEET NO. HAS BEEN PREPARED SPECIFICALLY FOR THIS PROJECT. THIS DOCUMENT IS NOT SUITABLE FOR USE ON OTHER PROJECTS OR IN OTHER LOCATIONS WITHOUT THE APPROVAL AND PARTICIPATION OF CARDINAL ENGINEERING ASSOCIATES. UNAUTHORIZED REPRODUCTION AND/OR REUSE IS PROHIBITED. SHEET TITLE: WEST HAMMOCK SITE LIGHTING PLAN REVISIONS: DESIGN BY: DATE: DJL 01/28/2020 DRAWN BY: CHECKED: NL JL E-07 OF 8 ELECTRICAL SHEETS