HomeMy WebLinkAbout06090020 - - - A. M. ENGINEERING AND TESTING, INC. 590 NORTHWEST MERCANTILE PLACE PORT ST. LUCIE, FLORIDA 34986 LOCAL OFFICE: (772) 924-3575 FAX: (772) 924-3580 DENSITY OF SOIL IN PLACE Contractor: Site: A WM Construction, Inc 2296 North U.S. Highway One Fort Pierce, Florida 34946 Client AI's Motor Homes, 120 Del Monte Street Fort Pierce, St. Lucie County, Florida Foundation Pad Report Date: January 15, 2007 Project No.: 1119 Lab No.: 11 Technician: P. Koch Page No.: 1 of 1 Permit No. 06090020 Client: Field Test Results Proctor Compaction Eleva- Max Test Date tion Dry Probe Dry In Min Pass/ No. Tested Location (ft) HCP H2O Density Depth Density Place Req'd Fail % (pet) (in) (pet) (%) (% ) 1 1/12/07 Southwest Corner 0-1 40 8.3 98.7 12 102.0 96.8 95 P 2 "" 1-2 50 95+ 95 P 3 Center Area 0-1 45 9.1 100.4 12 102.0 98.4 95 P 4 "" 1-2 60 95+ 95 P 5 Northeast Corner o - 1 40 6.4 99.1 12 102.0 97.2 95 P 6 "" 1 - 2 45 95+ 95 P RECEIVED MAR 2 6 2007 Public Works St. Lucie County, FL Remarks: All elevations are below bottom of slab. The field density tests were perfonned in general compliance with ASTM D 2922, Density of Soil in Place by Nuclear Methods. The Hand Cone Penetrometer (HCP) test, in conjunction with infonnation about the soil type, is empirically correlated to the relative density of the subsurface soils. The laboratory Proctor maximum dry density was determined in accordance with ASTM D 1557. PCM/sc Reviewed by: A. M. ENGINEERING ,AND TESTING, INC. f5b//1-C- i Ii £ (t; 7 Paul C. Martin, P.E. Florida Registration No. 65051 Distri bution: Client (3) F: \AM Data \A WM Construction, Inc. - Various - 1119\AI's Motor Homes, 120 Del Monte Street, Ft Pierce\]1 - AI's Motor Home - Dens Rpt