HomeMy WebLinkAboutProduct Approval - Dynamic Metal10/28/2019 Florida Building Code Online
nil 1(j�"g
SCIS Home Log In User Registration Hot 9bpics Submlt Surcharge Slats & Facts Publications Contact Us BCIB Site Map links Search
bpr
d J, �}Product Approval
9 USER: Public User
Product ARPrcval Menu > Product or Apylicatipn Search > Application List> Appliradon Oetell
- FL # FL27499-R1
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer Dynamic Metals
Address/Phone/Email 3201 SE Dominica Terace
Stuart, FL 34997
(772) 872-8030
juan@dynamicmetal.net
Authorized Signature Lara Jesus
juan@dynamicmetal.net
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Scott Wolters
Evaluation Report
Florida License PE -62354
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/31/2026
Validated By Lucas A. Turner, P.E., MBA
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL27499 RS COI Dyn COI.odf
Standard
Year
TAS 100
1995
TAS 110
2003
TAS 125
2003
haps://www.floddabuilding.org/pr/pr app_d8.aspx7param=wGEVXQwtDquHOE2Ywe%2bOsCepABg3%2bkM6B4KrS3X7m7RLNDTra/2fv7QaQ%,3d%3d 114
10/28/2019 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
02/22/2019
08/29/2019
08/30/2019
10/15/2019
FL it
Model, Number or Name Description
27499.1
DM Gass 1000 1" Nallstnp 26 Ga. galvalume coated steel roof panel, 16" wide, with 1"
snap fit seams.
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL27499 RI II NSSI6HZ.ptd
Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: Please see Eva] report for Umits of Use. FL27499 RI AE DM Evall.p>, f
Created by Independent Third Party: Yes
27499.2
DM Class 1000 1" Nailstrip,
.032" Aluminum roof panel, 16" wide, with 1" snap fit seams.
Limps of Use Installation Instructions
Approved for use in HVHZ: Yes FL27499 R1 II NSA36HZ.pdf
Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: Please see Eval report for Limits of Use. FL27499 RI AE DM Eval2.pdj
Created by Independent Third Party: Yes
27499.3
DM Class 1050 1 1/2" Nallstnp
.032" Aluminum Roof Panel, 19" Wide, with 1 1/2" snap fit
seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R1 R NSAI9HZ.pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters, P.E. FLPE# 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Umits of Use.
FL27499 Rl AE DM Eval3.pdf
Created by Independent Third Party: Yes
27499.4 DM Class 1050 1 1/2" Nailstrip
24 Ga. Galvalume coated steel roof panel, 19" wide, with 1
1/2" snap flt seams
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 Rl II NSSI9HZ.ptf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters, P.E. FLPE# 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Limits of Use.
EU7499 R1 AE DM Eval4.p_df
Created by Independent Third Party: Yes
27499.5 DM Class 1500 1 1/2" Mechanical
.032" Aluminum roof panel, 20" wide, with 11/2" standing
Seam
seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 RS II SSMSA201-1Z odf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
j Other; Please see Eval report for Limits of Use.
FL27499 R1 AE DM Eval5.gdf
Created by Independent Third Party: Yes
27499.6 OM Class 1500 1 1/2" Mechanical
16 oz. Copper roof panel, 16" wide, with 1 1/2" standing
Seam
seams.
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL27499 Rl U SSMSCHZ.odf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Limits of Use.
FL27499 Rf AE DM Eval6.gdp
Created by Independent Third Party:. Yes
27499.7
DM Class 1500 1 1/2" Mechanical
Seam
26 Ga. galvalume mated steel roof panel, 16" wide, with 1 1/2"
standing seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
FL27499 RI 1I 15MSS1626HZ.pdf
Verified By: Scott Wolters 62354
hftps://www.floridabuilding.org/pr/pi app_d8.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABg3°/"2bkM6B4KrS3X7m7RLNDTr%2fv7QaQ%,3d%3d 214
10/28/2019
Florida Building Code Online
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: Please see Eval report for Limits of Use. FL27499 R1 AE DM Eval7.pdf
I Created by Independent Third Party: Yes
27499.8 DMClass 1500 1 1/2' Mechanical 1 seams. Aluminum roof panel, 16" wide, with 11/2" standing I Scam
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
Installation Instructions
FL27499 RI II 15MSA16HZ.rAf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 R1 AE DM Eval8.pdf
Created by Independent Third Party: Yes
27499.10 DM Gass 1500 1 1/2" Mechanical 24 Ga. galvalume mated steel roof panel, 20" wide, with 11/2"
Seam, I standing seams.
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL27499 R1 II 15MSS20HZ.pdf
Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: Please see Eval report for Umits of Use. FL27499 R1 AE DM Eva110 pdf
Created by Independent Third Party: Yes
27499.11 DM Class 1750 13/4" Snaplock 24 1 . Galock me coated steel
roof to meta decB" wide, with 1
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL27499 RI II SLSIBBDHZ.odf
Approved for use outside HVHZ: Yes Verified By: Scott Wolters, P.E. FLPE# 62354
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: Please see Eval report for Limits of Use. FL27499 R1 AE DM Eva111 pdf
Created by Independent Third Party: Yes
27499.12 DM Bass 1750 13/4" Snaplock .032" Aluminum roof panel, 18" wide, with 13/4" Snaplock
seams, attached to metal deck.
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL27499 RS II SLA188DH2 pdf
Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: Please see Eva[ report for Limits of Use. FL27499 R1 AE DM Eva[12.pdf
I Created by Independent Third Party: Yes
27499.13 DM Class 1750 13/4" Snaplock 032" aluminum roof panel, 18" wide, with 13/4" Snaplock
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL27499 RI 11 SLAIBHZ.odf
Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: Please see Eval report for Limits of Use. FL27499 RI AE DM Eval13 pdf
Created by Independent Third Party: Yes
127499.14 DM Class 1750 13/4" Snaplock 24 Ga. galvalume coated steel roof panel, 18" wide, with 13/4"
Snaplock seams.
Limits of Use
Installation Instructions
27499.9 DM Class 1500 1 1/2" Mechanical
24 Ga. gals flume coated steel roof panel, 16" wide, with 1 1/2"
FL27499 R1 II SLSISHZ.pdf
Seam
standing seams.
Verified By: Scott Wolters 62354
Limits of Use Installation Instructions
Impact Resistant: N/A
Approved for use in HVHZ: Yes FL27499 R1 II 1SMSS16HZ.pdf
Design Pressure: N/A
Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354
Evaluation Reports
Impact Resistant: N/A Created by Independent Third Party: Yes
FL27499 Rl AE DM Eval14 pdf
Design Pressure: N/A . Evaluation Reports
Other: Please see Eval report for Limits of Use. FL27499 R1 AE DM Eval9.pdf
Created by Independent Third Party: Yes
27499.10 DM Gass 1500 1 1/2" Mechanical 24 Ga. galvalume mated steel roof panel, 20" wide, with 11/2"
Seam, I standing seams.
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL27499 R1 II 15MSS20HZ.pdf
Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: Please see Eval report for Umits of Use. FL27499 R1 AE DM Eva110 pdf
Created by Independent Third Party: Yes
27499.11 DM Class 1750 13/4" Snaplock 24 1 . Galock me coated steel
roof to meta decB" wide, with 1
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL27499 RI II SLSIBBDHZ.odf
Approved for use outside HVHZ: Yes Verified By: Scott Wolters, P.E. FLPE# 62354
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: Please see Eval report for Limits of Use. FL27499 R1 AE DM Eva111 pdf
Created by Independent Third Party: Yes
27499.12 DM Bass 1750 13/4" Snaplock .032" Aluminum roof panel, 18" wide, with 13/4" Snaplock
seams, attached to metal deck.
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL27499 RS II SLA188DH2 pdf
Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: Please see Eva[ report for Limits of Use. FL27499 R1 AE DM Eva[12.pdf
I Created by Independent Third Party: Yes
27499.13 DM Class 1750 13/4" Snaplock 032" aluminum roof panel, 18" wide, with 13/4" Snaplock
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL27499 RI 11 SLAIBHZ.odf
Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: Please see Eval report for Limits of Use. FL27499 RI AE DM Eval13 pdf
Created by Independent Third Party: Yes
127499.14 DM Class 1750 13/4" Snaplock 24 Ga. galvalume coated steel roof panel, 18" wide, with 13/4"
Snaplock seams.
27499.15 j DM Class 2000 2" Mechanical Seam ! .032 Aluminum roof panel, 18" wide, with 2" standing seams.
https:IANww.floddabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQMDquHOE2Ywe°/"2bOsCepABg3°/,2bkM6B4KrS3X7m7RLNDTrOlo2fv7QaQ%3d%3d 3/4
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R1 II SLSISHZ.pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Limits of Use.
FL27499 Rl AE DM Eval14 pdf
Created by Independent Third Party: Yes
27499.15 j DM Class 2000 2" Mechanical Seam ! .032 Aluminum roof panel, 18" wide, with 2" standing seams.
https:IANww.floddabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQMDquHOE2Ywe°/"2bOsCepABg3°/,2bkM6B4KrS3X7m7RLNDTrOlo2fv7QaQ%3d%3d 3/4
10/28/2019
Florida Building Code Online
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL27499 Rl II 2MSA18HZ.gdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other. Please see Eval report for Limits of Use.
FL27499 R1 AE DM EvalMpdf
Created by Independent Third Party: Yes
27499.16 DM Class 2000 2" Mechanical Seam
24 Ga. galvalume coated steel roof panel, 18" wide, with 2"
standing seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
EL27499 RI U 2MSSSBHZ.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Limits of Use.
FL27499 R1 AE DM Eva116.pdf
Created by Independent Third Party: Yes
27499.17 DM Class 500 SV Crimp
26 Ga. galvalume coated steel roof panel, 24" wide, with SV
crimp.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 RS II SVS.pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Limits of Use.
FL27499 R1 AE DM Eva117.12df
Created by Independent Third Party: Yes
27499.18
DM Class 500 5V Crimp
.032" Aluminum roof panel, 24" wide, with SV Crimp
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL27499 111 II 5VALodf
Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: Please see Eval report for Limits of Use FL27499 RI AE DM EvalMp&
Created by Independent Third Party: Yes
ME—M
contact Us :: 2601 Blair Stone Road, Tallahassee n. 32399 Phone: 850-487-1824
The State of Florida is an AA/EM employer. Cnpvdoht 200]-2013 State of Florida :: Privary, Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395.'Pursuant to Section 455.275(1),
norlda Statutes, effective October 1, 2012, licensees licensed under chapter 455, F.S. must provide the Department with an email address if they have one. The emails
pmvlded may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please dicr here .
product Approval Accepts:
rM ® ® a^h¢[M M
Credit Card
Safe
https://www.floddabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABg3a/a2bkM6B4KrS3X7m7RLNDTra/o2tv7QaQa/aid%3d 414
WOLTERS ENGINEERING
ENGINEERING, DRAFTING, CONSULTING
15211 97th Road N
West Palm Beach, FL 33412
Ph/Fx: (561) 225.1982
PRODUCT EVALUATION
(FOR HVHZ APPROVED PRODUCT)
PRODUCT: DM CLASS 1500 24 GA GALVALUME 1%" MECHANICAL SEAM 16" WIDE
ROOF PANEL (FLPA# 27499.9)
MANUFACTURER: DYNAMIC METALS, LLC
340 PIKE ROAD
WEST PALM BEACH, FL 33411
To all concerned,
The DM Class 1500 Series 24 Ga Galvalume 1Y2" Mechanical Seam 16" Wide Roof Panel, manufactured
by Dynamic Metals LLC, is a non-structural galvalume coated Flruropon painted steel roof panel (50 ksi min) that
meets the requirements of Sections 1507.4 and 1518.9 of the 6m Edition (2017) Florida Building Code. The panel
has been tested per TAS100 and TAS 125 by Intertek with results shown in test reports G3443.21-45044 and
H2687.02.450-44, and per TAS 110 by PRI Construction Materials Technologies, with results shown in test reports
VLS-004-02-01 and VLS-005-02-01.
Technical Documentation:
1. Drawing "15MSS16-HZ" dated 8/15119, signed and sealed by Scott Wolters, PE,
Test Reports listed above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE, and
by PRI Construction Materials Technologies, signed and sealed by Zachary R Priest, PE.
3. Supplemental Calculations to support "15MSS16-HZ" drawing, signed and sealed by Scott Wolters,
PE.
I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005
(4). Based on the limitations listed below and those provided in the documents above, this product meets all the
requirements of the 6th Edition (2017) Florida Building Code generally, and chapter 15 specifically, including the
HVHZ provisions.
Limitations: This panel is approved for use inside and outside of the HVHZ.
Overall Limitations: Maximum Panel Width: 16"
Minimum Rib Height: 1 '/"
Clip Anchors: 26 Ga galvanized steel, 2" long
Min. Slope: HVHZ: 2"l12"
Non-HVHZ: '/z'/12"
I
SPECIALIZING IN IMPACf PE515fANf CLRrAINWAU.5, 5f0kt!P OW5, & WINPOW5
Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current
fire directory listing for fire ratings of this roofing system assembly as well
as the location of the fire barrier within the assembly. (See note #2 below)
Note: Outside of the HVHZ, 1" round plastic caps may be used to prevent
galvanic reactions.
Underlavment: Minimum ASTM D 226 Type II with 4" overlaps and 6" end -laps, anchored
with 12 Ga. x 1 Y+" galvanized roof nails with 32 Ga. Tin caps spaced 6"
O.C. in rows at the perimeter, at overlaps, and two intermediate rows
staggered and spaced 12" O.C.
(or)
Any underlayment with a valid FLPA or Miami -Dade NOA
Note: Outside of the HVHZ, 1" round plastic caps may be used to prevent
galvanic reactions.
Minimum Substrate: Y2'(1 5/32" min) 4 -ply CDX Plywood, nailed to 2x rafters spaced 24" max.
O.C. with 8d ring -shank nails spaced 4" O.C.
Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or
1515.2.
2. Fire classification is not a part of this evaluation. Refer to a current
Approved Roofing Materials Directory for fire ratings of this product.
3. Design of substrate is by others and is not a part of this evaluation.
4. Rational analysis, provided by a Florida licensed Architect/Engineer
per FAS 61 G20.3.005(e), may be used for project specific approval by
the local authorities having jurisdiction.
5. All panels shall be permanently labeled with the manfacturer's name
and/or logo, and the following statement, "Dynamic Metals
FL# 27499.9, DM Class 1500".
5FECIFi.IZIN64 IN IMFACt k'c5l5TANf C0AINWALI,5, 5f0REF70NT5, & WIN12OW5
Field
Installation
Perimeter & Comer
Installation
Max. Design Pressure:
-166 psf
-198.5 psf
Clip Anchor Spacing:
4" From Ends, 16" Max. O.C.
4" From Ends, 8" Max. O.C.
Min Panel Fasteners:
910x1" Panclip Fasteners
(2) Per Clip
#10x1" Panclip Fasteners
(2) Per Clip
Panels are Seamed to 900
Panels are Seamed to 90°
Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current
fire directory listing for fire ratings of this roofing system assembly as well
as the location of the fire barrier within the assembly. (See note #2 below)
Note: Outside of the HVHZ, 1" round plastic caps may be used to prevent
galvanic reactions.
Underlavment: Minimum ASTM D 226 Type II with 4" overlaps and 6" end -laps, anchored
with 12 Ga. x 1 Y+" galvanized roof nails with 32 Ga. Tin caps spaced 6"
O.C. in rows at the perimeter, at overlaps, and two intermediate rows
staggered and spaced 12" O.C.
(or)
Any underlayment with a valid FLPA or Miami -Dade NOA
Note: Outside of the HVHZ, 1" round plastic caps may be used to prevent
galvanic reactions.
Minimum Substrate: Y2'(1 5/32" min) 4 -ply CDX Plywood, nailed to 2x rafters spaced 24" max.
O.C. with 8d ring -shank nails spaced 4" O.C.
Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or
1515.2.
2. Fire classification is not a part of this evaluation. Refer to a current
Approved Roofing Materials Directory for fire ratings of this product.
3. Design of substrate is by others and is not a part of this evaluation.
4. Rational analysis, provided by a Florida licensed Architect/Engineer
per FAS 61 G20.3.005(e), may be used for project specific approval by
the local authorities having jurisdiction.
5. All panels shall be permanently labeled with the manfacturer's name
and/or logo, and the following statement, "Dynamic Metals
FL# 27499.9, DM Class 1500".
5FECIFi.IZIN64 IN IMFACt k'c5l5TANf C0AINWALI,5, 5f0REF70NT5, & WIN12OW5
Panel Forming: These panels may be jobsite roll formed with the following Dynamic Metals machines, per
approval of 3b party QA provider, to the dimensions shown on Drawing 15MSS16-HZ:
SSQ-6800617 SSQ-5150216 SSQ-6810617
SSQ-6690517 SSQ-4560615 SSQ-8681118
5VC-0490718 5VC-0360516 5VC-0521218
Re -Roofing: The DM Class 1500 Series 24 Ga Galvalume 1 %2' Mechanical Seam 16" Roof Panel may
be installed over a single layer of existing asphalt shingles, provide the existing roof meets
the requirements of Section 1521 (HVHZ) or Section 1511 (outside of HVHZ) of the Florida
Building Code.
If you have any questions or need more information concerning this approval please contact me.
Thank you,
,tttt?{!r967�r Pe
w
` CE Sc 9s
N � 23354
fiG
Scott �/Vglters
FL PE# 52354
o. STATE of 441
AN 16 7.019
,
o o
s
''«E�ea9cns+ttt•
5r'�CIAJZIN, IN A4pACr k" 515 1W CS1AININPo_I-5, 7fCKUFON"5 R WINn0N5
9,: ,' E 0". I..',
a1 (rxI Pt➢o{m :11VtN3 88ZL'eZ4 (L9.1 Hd
at/ais - lrumere ist :'.>�.6tp2� i911W ':`'=_face varravaa rcna asp lau iataw.vwoud e y
Ei/st e - 39narq 3wrn ' ^�:• - - n wcu wts umr L6ZL-6Z. (1951 =%Vd Z84'li 'H7tl8B — 183M I
ObOV avid OCF `, m
SIVi3W JIAVNAG
U
LL
Lu �0�/
I.L
J J
Q W
_U W
�Z� H
V W
O
V
w
W
® _0
J
LO
cn
r J
Q CD CC
{I U LU
V
10 N d
U
n
k
m
c
U
N
d
m U
in o
c
y U ¢
cl)
gm
ayW
min
co m
N �
li
U
n
k
U
Y
d�F'l
`o
a
a
�