Loading...
HomeMy WebLinkAboutChandler Window_S&S PlansWINDOW REPLACEMENT LAYOUT �Z,cl4 f e ,0,' GE N S FI -e L: s9, � OP WINDOW SCHEDULE MARK SIZE MANUFACTURER PRODUCT APPROVAL AGENCY EXP. DATE DESIGN ZONE DESIGN PRESSURE MAX. WINDOW PRESSURE WIDTH HEIGHT 1 37" 63" PGT WINGUARD NOA #18-0430.06 MIAMI—DADE 8/23/23 5 +46/-79 +65/-80 *WINDOW IS A DOUBLE SIZE W/ TUBE MULLION PER NOA #17-0630.01 (EXP 5/26/2021) S-1 Staggered Fc 1j" Min. Em into Pressure Treated Wood Buck WINDOW/DOOR BUCK Tonal at Doors Wood Buck Notes 1. Window/Door Buck Fastening details are to meet or exceed the manufgacturer's test approvals and recommendations. 2. Bucks are designed for wind load compliance only. Design for impact resutance shall require additional fasteners and/or bucking as specified by the window/door manufacturer specialty engineer in accordance to the 2017 FBC, 6th Edition. 5. Bucks are to be fastened horizontally and vertically to poured concrete beams and columns, or concrete filled masonry units, respectively. 6. Bucks are to be 1x6 or 1x8 #2 PT Southern Pine per industry standards and fully bonded to concrete/masonry w/ SIKA 1A Construction Adhesive. For multiple buck installation, bucks are to be fully bonded and fastened to each other. 7. Buck fasteners are to be J"O TAPCON with 1j" minimum embedment into concrete//masonry with staggered spacing equal or exceeding the manufacturer's fastening schedule for framing. Verification of Construction Conditions E A. E E M: tali ne bidding only. a J �E .E B. Contractor shall inspect existing conditions and verify 0 Vi V GENERAL STRUCTURAL NOTES Uj co Applicable Codes o x Lj<n W V0 zao A. Construction shall be in accordance with the 2017 Q"" Florida Building Code, 6th Edition, ASCE 7-10, ASD, ;�,� and AISC. The above shall govern except where other NOAo applicable codes or the construction drawings are more ` drawings. Any variations of the constructions drawings restrictive. without the Engineer of Record consent are the Design Criteria responsibility of the contractor and owner. Mean Roof Height 200' The construction drawings depict a finished product Wind Load 2017 FBC & Ch. 1-2, 26 and all temporary bracing and means and methods of z Wind Velocity 170 mph Ult; 132 Nom construction are the responsibility of the Contractor. LU Exposure D All Door and Window Products shall be furnished and ROUGH QZ 96 psf installed in accordance to all applicable governing Q OPENING Kd 0.85 codes and manufacturer specifications. a KZ 1.61 All details, sections, and notes on the drawings are W w Reduction Factor 0.6 intended to be typical and shall apply to sirrillar Roof Slope Flat situations elsewhere unless otherwise shown. Internal Pressure Coef. +/-0.18 Risk Category II Tonal at Doors Wood Buck Notes 1. Window/Door Buck Fastening details are to meet or exceed the manufgacturer's test approvals and recommendations. 2. Bucks are designed for wind load compliance only. Design for impact resutance shall require additional fasteners and/or bucking as specified by the window/door manufacturer specialty engineer in accordance to the 2017 FBC, 6th Edition. 5. Bucks are to be fastened horizontally and vertically to poured concrete beams and columns, or concrete filled masonry units, respectively. 6. Bucks are to be 1x6 or 1x8 #2 PT Southern Pine per industry standards and fully bonded to concrete/masonry w/ SIKA 1A Construction Adhesive. For multiple buck installation, bucks are to be fully bonded and fastened to each other. 7. Buck fasteners are to be J"O TAPCON with 1j" minimum embedment into concrete//masonry with staggered spacing equal or exceeding the manufacturer's fastening schedule for framing. Verification of Construction Conditions Z A. Dimensions and elevations of construction are for10 bidding only. a B. Contractor shall inspect existing conditions and verify o dimensions, elevations, etc.. which affect the scope on the construction drawings. C. The Engineer of Record shall be notified of any variations or discrepancies on the construction drawings. Any variations of the constructions drawings without the Engineer of Record consent are the responsibility of the contractor and owner. D. The construction drawings depict a finished product and all temporary bracing and means and methods of z construction are the responsibility of the Contractor. LU E. All Door and Window Products shall be furnished and installed in accordance to all applicable governing Q ���•�"""����,, codes and manufacturer specifications. W J GE, ?gM,y�00 '�.� F. All details, sections, and notes on the drawings are W w �;r�Q.`GEN8,e . intended to be typical and shall apply to sirrillar t?: �. * situations elsewhere unless otherwise shown. 313 Z �0 W Q J y W : �? S -O: ST�P �� 9 • 2'4 0 2 �,s It %%% u1 S-2