HomeMy WebLinkAbout07030014 ~~~%~~ Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stlucieco.gov/ce Review Comments for Owner Page 04/12/2007 ALICE R KIEL 703 RAMIE CT PORT ST LUCIE, FL 34952-1353 Permit Number: 0703-0014 As of tOday's date your Contractor is being notified along with yourself that the referenced building permit has some issues listed in the comments below. We have asked that these issues be dealt with as quickly as possible so that we are able to continue to process this permit in a timely manner. This information is being shared with you so you are aware of the status of your permit. PROPERTY INFORMA TION 703 RAMIE PORT ST LUCIE 34952 APPLICA TION INFORMA TION CT CONTRACTORS INFORMA TIOJ 10765 IZZO BUILDERS INC IZZO THOMAS F 1338 SW BIL TMORE ST PORT ST LUCIE, FL 34983 Permit Number: 0703-0014 Activity Type: New Permit Type: Building Residential (SFR) Application Type: Master Permit w/subs Other Activity: Stories 2 REVIEWS AND COMMENTS Review TVDe Addressing Assignment ~ Complete Reviewed By Jodee Vorreyer Date Started Date ComDlete Date Released 03115/2007 03115/2007 Review TYDe Documents Missing ~ Pending Reviewed By Date Started Date ComDlete Date Released 03/08/2007 1 04/12/2007 2 Comment NEEDS THE VEGE PERMIT NUMBER ON THE BACK OF THE PERMIT APPLICATION. Comment SURVEY SHOWS FLOOD ZONE X. FEMA MAPS SHOW AE 7. PLEASE VERIFY AND CORRECT SURVEY. 04/12/2007 3 Comment FFE MUST BE TYPED ON SURVEY, CAN NOT BE WRITIEN ON SURVEY PER LAND DEVELOPMENT CODE BOOK. Review TYDe Front Counter Review ~ Complete Reviewed Bv Barbara Counsellor Date Started Date ComDlete Date Released 03101/2007 03101/2007 .9Þ;~~ ~ .~;t""þc~~~p:·~b Review Comments for Owner Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stlucieco.gov/ce Page 2 Review TYDe Notified for Pickup Status Pending Reviewed By Date Started Date ComDlete Date Released Review TYDe Plans Examiner Review Status Incomplete Reviewed BY Joe Cicio Date Started Date ComDlete Date Released 04112/2007 04/12/2007 1 Comment FBPE RULE 61G15-23.001 ** ENGINEER SEAL CHANGE 02/05/2004 ** CONTRACTOR TO RE-SUBMIT ALL PLANS AND ASSOCIATED DOCUMENTS WITH CURRENT ENGINEERS SEAL REQUIREMENTS 04/12/2007 2 Comment ENGINEER TO FILL OUT THE PROJECT NAME AND ADDRESS ON THE" ST LUCIE WIND LOAD COMPLIANCE SHEETS" IN DUPLICATE 04/12/2007 3 Comment ALL PLANS AND SPECIFICATIONS MUST BE DESIGNED TO THE 2004 FBC W/ THE 2006 REVISIONS * NOTE ON PLANS OR BY LETTER * DUPLICATES * 04/12/2007 4 Comment CONTRACTOR TO SUBMIT CURRENT, DUPLICATE ENERGY CALCS PROPERLY SIGNED, IN ACCORDANCE WITH 13-600.3.ABC.3 FBC 06 REVISIONS FOR REVIEW 04/12/2007 5 Comment CONTRACTOR TO SUBMIT DUPLICATE MANUAL J CALCS IN ACCORDANCE W/ FBC 13-607.1.ABC.1 [2006 REVISIONS] FOR REVIEW 04/12/2007 6 Comment CONTRACTOR TO SUBMIT DUPLICATE MANUFACTURERS ROOF AND FLOOR TRUSS LAYOUTS IN ACCORDANCE WITH FBCR802.1.6 SIGNED AND SEALED BY THE TRUSS SYSTEM ENGINEER AND REVIEWED AND APPROVED BY THE ENGINEER OF REORD.** DESIGN TO THE 2004 FBC W/ 2006 REVISIONS ** 04/12/2007 7 Comment 04/12/2007 8 Comment 04/12/2007 9 Comment 04/12/2007 10 Comment 04/12/2007 11 Comment 04/12/2007 12 Comment 04/12/2007 13 Comment ENGINEER TO INCLUDE THE MANUFACTURERS ID, FASTENERS, DESIGN PRESSURES,AND REQUIRED UNDERLAYMENT ON THE PLANS FOR THE METAL ROOF-SYSTEM. PRIMARY EGRESS DOOR [front] MUST PROVIDE 29" CLEAR OPENING * CHAPTER 11 * SEE R-311.4.2 AND R-311.4.4 * ENGINEER TO DESIGN THE UPSTAIR, EXTERIOR GUARDRAIL SYSTEM ON THE PLANS PER FBC CHAPTER 20 AND FBC LOADS 1607.7.1 ENGINEER TO DESIGN THE UPSTAIR AND DOWNSTAIR" SCREEN WALL INFILLS" AS SHOWN ON PLANS PER FBC CHAPTER 20 ENGINEER TO DETAIL THE INTERIOR STAIRWAY, GUARD AND HANDRAIL SYSTEM ON THE PLANS PER R-311 & R-312 * ALSO INCLUDE LOADS PER 1607.7.1 * ENGINEER TO DESIGN THE BALANCED RETURN AIR SYSTEM ON THE PLANS PER FBCM 601.4 N.O.A.01-0629.08 HAS EXPIRED AND DOES NOT IDENTIFY THE CLEAR OPENING REQUIREMENTS OR THE S.F.REQUIREMENTS FOR EMERGENCY EGRESS ON THE FIRSTR AND SECOND FLOOR. ~4~~~ Code Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-2522 http://stlucieco.gov/ce Review Comments for Owner Page 3 04/12/2007 14 04/12/2007 15 04/12/2007 16 04/12/2007 17 Comment N.O.A.01-0629.08 HAS EXPIRED * PLS CLARIFY IN TABLES * Comment N.O.A. 01-0417.04 HAS EXPIRED * PLS CLARIFY IN TABLES * Comment BATH EXHAUST VENTS MUST TERMINATE TO THE EXTERIOR OF THE BUILDING Comment DRYER VENT CANNOT CONNECT TO ANY DUCTWORK * CLARIFY ON PLANS THE DESIGN AND DRYER VENT MUST TERMINATE TO THE EXTERIOR OF THE STRUCTURE 04/12/2007 18 Comment COMMENTS MAILED TO OWNER AND CONTRACTOR AS OF THIS DATE Review TVDe Supervisor Review Status Complete Reviewed Bv Lynn Swartzel Date Started Date ComDlete Date Released 03116/2007 03116/2007 Review TVDe Zoning Review Status Complete Reviewed Bv Jodee Vorreyer Date Started Date ComDlete Date Released 03107/2007 03116/2007 n~ ';r': .~>-o .~I-~ ;,zœ ~ .... 0 . ::~ ""j ~o~ :,;t:~~ U y. p,... ~) ~ Tf 0 V " t LtI) I\.. ~ .,... , 0 ! - ¢ W 10 - tl}- 0 (IJ œ - UJ lit ~ (') iLl an t'- Ita Ò - - O:CiI1: t wa([ U) 0([3 0 - z n: TI IJJUJO "" - U)([f..l. « " owo - f-Jt- ... m - z«W (\1 - ftitJ (') - ct :Jwm œ : (t) 1-. > ([ (Jt - (T) WHZ U) ß:..J:) an w Cr4 c m 0\ - t- ~ = w 0 ~ H :z x .. -- H U %. m I I I ti i ,.:t- ii) N ('f) co LO N ooz .... ~ 0 t- CIJ C'J ëi) z~ii> ~=uiC QQ~UJ O...~~ __Cl.~ ¡.¡.J r ~ .-: - - "wi U. ...J 0- _D.. ;J ...I uj. :e 1=> 0 - « 0 · ~ ~ w ~Q.~o rLJ Q1 0 9;0 > o o ('f') N . 1