Loading...
HomeMy WebLinkAbout07030377 FEDERAL CLIENT: P AULA MAR TIN 3404 A VENlÆ N, FORT PIERCE2 FLORIDA 34947 PROPOSED ADDITION BUILDING PAD FIELD DENSIty TESTS OF COMPACTED SOILS Public Works St. Lucie County, FL 1 ORDER NO: 07-927 PERMIT NO. C170~ - 03'7 _ ENGINEERING & TESTING POMP'l~~~!'~9 APR 1 2 2007 I 798 AGORA CIRCLE S.E. SUITE 5 PALM BAY, FLORIDA 32909 3/27/07 DATE: ADDRESS: PROJECT: ADDRESS: 3404 AVENUE N. FORT PIERCE. FLORIDA MATERIAL DESCRIPTION: BROWN SILICA SAND W/SOME CLAY & TRACES OF SHELL FRAGS LOCATION: N.E. CORNER OF PAD S. W. CORNER OF PAD S.E. CORNER OF PAD LOCATION: LOCATION: LOCATION: LOCATION: LOCATION: FIELD DENSITY METHOD AS.T.M. D-2922 DRY DENSITY P.C.F. IN THE FIELD 1 08.1 107.4 107.9 % MOISTURE 9.8 10.3 9.3 % COMPACTION IN THE FIELD 98.6 97.9 98.4 % COMPACTION REQUIREMENT 95% PROCTOR VALUE, P.C.F. 1 09 . 7 OPTIMUM MOISTURE, % 12.5 LABORATORY NO. P-716 DEPTH IN INCHES 12 PROCTOR A.S.T.M D-1557 METHOD REMARKS: SOIL NOT TESTED BELOW FOOTERS TESTED BY: SL CHECKED BY: KM RespectfuIIy submitted, . Þ/!JJ'Jrl:~ /j.qlp7 ~ISSAM S. NAAMANI, P.E. '/ · FEDERAL ENGINEERING & TESTING FLORIDA REG. #39584 As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts ftom or regarding our reports is reserved pending our written approval. A density test detennines the degree of compaction of the tested layer of material only. A density does not replace a soil bearing capacity determination.