Loading...
HomeMy WebLinkAboutRoof Coverings Attachment Calc'sAtlantic & Caribbean Roof Consulting 5001 North Hiatus Road, Sunrise, FL 33351 (AA[..SRC Certificate of Authority No. 9036 ROOF COVERINGS ATTACHMENT CALCULATIONS Page 1 of 2 Date: 3/24/2020 ACRC # 20-0197 CLIENT: TOTAL ROOFING SYSTEMS PROJECT NAME: HARBOR RIDGE - SWEET BAY VILLAGE POOLHOUSE PROJECT ADDRESS: 1580 SWEET BAY COURT PALM CITY, FLORIDA 34990 PROJECT DATA: HEIGHT: (FEET) 15.0 PRESSURE COEFFICIENT: WIDTH: (FEET) 30.0 SLOPE: < 7 DEG. YES Kz = 2.01[(HEIGHT/900)A(2/9.5)] CONT. PARIPET WALL:>=3' NO Kz = 0.85 ENCLOSURE CLASS: ENCLOSED RISK CATEGORY: 11 REGION: SOUTHEAST DESIGN WIND SPEED: 170 MPH EXPOSURE: C VELOCITY PRESSURE: qz qz = 53.38 Kzt = 1.0 Kd = 0.85 Dqz = 32.03 UPLIFT PRESSURES: DESIGN CRITERIA: FLORIDA BUILDING CODE P1 = 37.80 PSF EDITION 2017 P2 = 63.42 PSF WIND DESIGN PER ASCE 7-10 P3 = 95.45 PSF PERIMETER WIDTH: USE A MIN. OF: 4.00 FEET Atlantic & Caribbean Roof Consulting 5001 North Hiatus Road, Sunrise, FL 33351 ROOF COVERINGS ATTACHMENT CALCULATIONS SYSTEM TYPE: DM CLASS 1500 24 GAGE GALVULUME COATED STEEL PANELS SYSTEM DATA: MANUFACTURER: NOA OR PRODUCT APPROVAL NUMBER: PAGE NUMBERS: DECK MATERIAL: UNDERLAYMENT: FIRE BARRIER: METAL PANEL: DESIGN PRESSURE: (PSF) DESIGN PRESSURE: (PSF) CONSTRUCTION TYPE: ATTACHMENT: UNDERLAYMENT: PER FPA FIRE BARRIER: PER FPA VALLEYS: PER FPA METAL PANELS: PER FPA Page 2 of 2 Date: 3/24/2020 ACRC # 20-0197 DYNAMIC METALS, LLC FL27499.9 PAGE 3 WOOD PER FPA PER FPA PER FPA PER FPA -166.00 (FIELD) -198.50 (PERIMETERS AND CORNERS) RE -ROOF Digitally signed by Randall Fowler CALCULA" DN: C=US, RANDALL Randall Fowler E=rfowler@roofconsultant.net, O=ACRC, CN="Randall Fowler " NO. 5115 Date: 2020.03.25 11:15:20-04'00' ®ALL• 011 � N o m �s SB 7q] P. U• �= * y? lriruiiru�rtiti�