HomeMy WebLinkAboutProduct Approval - UnderlaymentI IUIIUCI riyy
'4,;�.' Product Approval
USER: WOlic User
ry) Product PproVal Menu > Product or Application Search > Aypiication List> Application Detail
N. ,'v v "qR.: f�r �5 Ai
I `,� FL # FL11602-R10
pd"v�".wf�us Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Owens Coming Roofing and Asphalt, LLC
One Owens Corning Parkway
Toledo, OH 43645
(740)321-6345
Greg. Keeler@owenscoming.cem
Keeler Greg
Greg.Keeler@owenscoming.com
Greg Keeler
2790 Columbus Road
Granville, OH 43023
(740)321-6345
gmg.keeler@owenscoming.com
Roofing
Underiayments
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer I�
. Evaluation Report - Hardoopy Receivga
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License
PE-59166
Quality Assurance Entity
Intertek Testing Services NA, Inc. - QA Entity
Quality Assurance Contract Expiration Date
12/31/2020
Validated By
John W. KnezeAch, PE
+ Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
FL11602 Rln COI 201g 01 COI NIEMINEN pdf
Standard
ASTM D1970
ASTM D226 (physicals)
ASTM D4798
FRSA/TRI April 2012
TAS 117(B)
UL1897
Year
2015
2009
2011
2012
1995
2012
Equivalence or Product Standards
Certified By
hthls:/A w finridahuildinn.nm/nr/nr ann
2/18/2020
Sections from the Code
Florida Building Code Online
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summaryof Products
I �
Method 1 Option D
10/17/2019
10/17/2019
10/20/2019
12/10/2019
FL #
Model, Number or Name
Description
11502.1
Titanium Roof Underlayments
Synthetic sheet -type roof underlayments
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-45
Other: 1.) The design pressure noted herein pertains to use -of
a specific underlayment system beneath foam -on tile sytsems.
Refer to ER Section 5.6.3 for details. 2.) Refer to ER Sections 5
Installation Instructions
FL11602 R10 11 2019 10 FINAL ER FL11602-RSO pf
Verified By: Robert Nieminen PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
FL11602 RIO AE 2019 10 FINAL ER 1602-R10 pdf
Created by Independent Third Party: Yes
and 6 for other Umits of Use.
each next
Qnmct Us:: 2§9- kir Stone Road, Tallahassee FL 32399 Phone: 850-087-1824
The State of Flonde is an WIM0 employer. _['_novriaM 20n7-2013 State of Fbnda.:: privacy Statement :: AccessibiliN Statement:: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(l),
Florida Statutes, effective October 1, 2012, licensees licensed under chapter 455, FS, must provide the Department with an email address if they have one. The emaik
provided may be used for of8dal communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Oeparbnent with an email address which can be made available to the public To determine if you are a licensee under chapter 455, F.S., please dick here .
Product Approval Accepts:
MM ® eCtart
Credit Card
Safe
httpsJ/www.floiidabuilding.org/prfpr_app dtl.aspX?oaram=wGEVXQhivtpDsOFKKM 9tTr7auvra�llr 41CLd.p/_Ofcr.ann/...+ao..n...�c�_nmin ..� _�
ENGINEER EVALUATE
NEMO I etc.
Certificate of Authorization #32455
313 Christian Street, Unit #13
Oxford, CT 06478
(203)262-9245
TEST CONSULT CERTIFY
Owens Corning Roofing and Asphalt, LLC Evaluation Report 111580.11.08-R11
One Owens Coming Parkway FL11602-R10
Toledo, OH 43659 Date of Issuance:11/03/2008
(740) 321-6345 evision 11: 10/17/2019
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use ofthe product underthe Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 6"t Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION: Titaniumn" Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the 'referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEW ETC, LLC requires a complete review of
this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADvERTISEMENT: The Evaluation Report number preceded by the words "NEMOI etc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through S.
Prepared by:
Robert J.M. NIemIDF.O, P.E. rX- The facsimile seal appearing was authorized by Robert
Florida Registration No. 59166, Florida DCA ANE1983 s,: v;;..:rjPNieminen,P.E on 10/17h019. This doers notseve as an
electronically signed comment
C�Ri1FlfAi10N OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
©2018 NEMO ETC, LLC
04NEm'�
O I etc.
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Titanium'' Roof Underlayments, as produced by Owens Corning Roofing and Asphalt, LLC,
have demonstrated compliance with the intent of the following sections of the 6"' Edition (2017) Florida Building
Code through testing in accordance with applicable sections the following Standards. Compliance is subject to the
Installation Requirements and Limitations / Conditions of Use set forth herein.
Section
1504.3.1
1507.1.1, R905.1.1 Exception
1507.1.1, R905.1.1 Exception
1507.1.1, T1507.1.1,1507.2.9.2
1507.3.3
TAS 110
TAS 110
Entity
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD M6049)
ITS (TST1509)
ITS(TST1509)
ITS(TST1509)
ITS (TST1509)
ERD (TST6049)
Owens Corning
PRI 01T5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI(TSTS878)
PRI(TST5878)
PRI (TST5878)
PRI(TSTS878)
PRI (TST5878)
PRI(TST5878)
PRI (TST5878)
PRI OY 5878)
PRI(T5T5878)
ITS (QUA1673)
ITS (QUA1673)
Wind Uplift
Unrolling, Breaking Strength, Pliability
Tear Strength
Physical Properties
Physical Properties
Accelerated Weathering
Pull -through resistance
Physical Properties
Physical Properties
ASTM D226
Wind Uplift
ASTM D226
ASTM D226
Physical Properties
ASTM D226
Physical Properties (NH)
Product equivalency
ASTM D1970
ASTM D1970; Tear strength
ASTM D1970; Tear strength
ASTM D1970; Tear strength
FRSA/TRI April 2012 (04-12), partial
ASTM D4798
TAS 117(g); Pull -through
FRSA/TRI April 2012 (04-12), partial
ASTM D226 ASTM D4798
ASTM 0226/ASTM D4798
ASTM D226 ASTM D4798
UL1897
Tensile adhesion
Quality Control
Quality Control
,Standard -
year
UL1897
2012
ASTM D226
2009
ASTM D1970
2015
ASTM D1970
2015
FRSA/TRI April 2022 (I .4-12)
2012
ASTM D4798
2011
TA5117(B)
1995
115010.04.09
115010.05.10
135520.06.11
138010.08.11
135520.08.11-1
311801000Q-003
3130639COQ-002A
3126617COQ-005
101823107COQ7011
4j-OC-19-SSUDL-0IA
Declaration
OCF-341-02-01
OCF-331-02-02
OCF-332-02-02
OCF-334-02-02
OCF-343-02-01
OCF-341-02-01
OCF-422-02-02
OCF-425-02-01
OCF-331-02-01 R1
OCr-332-02-01 R1
OCF-334-02-01 Rl
1378TO02
OCF-507-02-01
ITS Listings
Service Confirmation
Date 1 1
04/29/2009
05/14/2010
06/15/2011
08/11/2011
08/12/2011
04/26/2007
08/21/2907
10/31/2007
01/23/2015
06/14/2019
06/18/2018
09/20/2017
10/03/2017
10/03/2017
10/03/2017
11/09/2017
11/27/2017
04/03/2018
08/13/2018
05/07/2019
05/07/2019
05/07/2019
07/10/2019
08/13/2019
Current
09/30/12017
NEMO ETC, LLC Evaluation Report 11198011.06-R31
Certificate of Authorization#32455 0 EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-R30
Titanium Roof Underlayments Revision 11: 10/17/2019
Page 2 of 8
NNEIMO i etc.
Product Specification Plants Description
4.1 TitaniumTM PSU-30 ASTM D1970 Dubai, UAE & unreinforced polymer modified bitumen material adhered
and FRSA/TRI Brentwood, NH to the underside of a polymer -coated, synthetic woven'
April 2012 sheet. The underside is backed with a release film. Unit
weight 24lbs/square
4.2 Titanium"' UDL-25 FBC 1507.1.1 Qingdao, China synthetic sheet -type underlayment comprised of a woven
& R905.1.1 core coated on one side with a polymer coating. Unit
(Exception) weight 2.5 lbs./square `
4.3 Titanium"" UDL-30 FBC 1507.1.1 Mission, BC, synthetic sheet -type underlayment comprised of a woven
& R905.1.1 Canada & core coated on both sides with a polymer coating. Unit
(Exception) Qingdao, China weight 4.0 lbs./square
4.4 TitaniumTM UDL-50 FBC 1507.1.1 Mission, BC, synthetic sheet -type underlayment comprised of a woven
& R905.1.1 Canada & core coated on both sides with a polymer coating. Unit
(Exception) Qingdao, China weight 4.7 lbs./square f
• e
5.1 This is a building code evaluation. Neither NEW ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
I
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of
this product.
5.4 TitaniumTM Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request maybe made to the Authority Having Jurisdiction
for approval based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Asphalt
Wood Shakes
Underlayment
Shingles
Nail -On Tile
Foam -On Tile
Metal
& fhfngles
Slate
Titanium PSU-30
Yes
Yes
yes
Yes
Yes
Yes
(See 5.5.1)
Titanium UDL-25
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Titanium UDL-30
Yes
(aaze shee 1.2-pry
iease5hsetin2yly
Yes
Yes
I Yes
system)
system)
Titanium UDL-50
Yes
No
No
Yes
Yes
Yes
NEMO ETC, LLC Evaluation Report IM80.11.08-R31
Cerdfimte ofAvrhorimtion N32455 6'H EDITION (20171 FBC NON-HVHZ EVALUATION FL11602-R10
Titanium Roof Underlayments Revision 11: 10/17/2019
Page 3 of 8
i
O � etc.
5.5.1 "Foam -On Tile" is limited to use of following Approved file adhesives / underlayment coll�NEMbinations.
5.6
5.6.1
TABLE SA: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATLON51
Underlayment
Adhesive
Florida Product Approval
Titanium PSU-30
OUPONTTile Bond'"
FL22525
ICP Adhesives Polyset* AH-160
FL6332
ICP Adhesives Polyset° RTA-1
FL6276
Allowable Substrates (for self -adhering):
TABLE 2: SUBSTRATE OPTIONs
Underlayment
Primer
Substrates
Titanium PSU-30
(Optional) ASTM D41
plywood
None
ASTM D226 felt
ASTM D41
Titanium UDL-30
None
Titanium U L-30 (inverted)
#1
Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI Aril 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment
forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is
the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Referto FRSA/TRI April
2012 (04-12), Appendix A, Table SA or FBC 1609 for determination of design wind loads,.
Maximum Design Pressure=-45 osf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: (Optional) ASTM D41
Underlayment: One or two plies, Titanium PSU-30, self -adhered and back -nailed max. 6" o.cl with 12 ga.
galvanized annular rink shank nails through 32 ga., 1-5/8-inch diametertin caps in accordance with
Owens Corning Roofing and Asphalt, LLC published installation requirements.
#2 Maximum Design Pressure=-30 osf*:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Titanium UDL-30 (inverted)
Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not Less than 3/8 inch
diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch
with min. 32 ga., 1-5/8" diameter tin caps
Spacing: 6-inch o.c. at 4-inch wide side laps and 12-inch o.c. at three (3), equally spaced center rows.
Primer: ASTM D41 primer required at all tin -caps.
Underlayment: One ortwo plies, Titanium PSU 30, self -adhered and back -nailed max. 6" o.c. with 12 ga. galvanized
annular rink shank nails through 32 ga., 1-5/84nch diameter tin caps in accordance with Owens
Corning Roofing and Asphalt, LLC published installation requirements.
1 Refer to Tile Manufacturers or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC, LLC Evaluation Report 111986.11-08-Rll
C r*o,fe ofAuthorization#32455 6" EDITION (2017) FBC NON-HVHZ EVALUATION 1 FL11602-R10
Titanium Roof Underlayments Revision 11: 10/17/2019
Page 4 of 8
NI
6VEM'0I etc.
#3 Maximum Design Pressure=-30 osf':
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Titanium UDL-30 (printed side up)
Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch
diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch
with min. 32 ga., 1-5/8" diameter tin caps.
Spacing: 6-inch o.c. at 4-inch wide side laps and 12-inch o.c. at three (3), equally spaced center rows.
Primer: ASTM D41 primer required over printed side of UDL-30.
Underlayment: One or two plies, Titanium PSU 30, self -adhered and back -nailed max. 6" o.c. with 12 ga. galvanized
annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens
Corning Roofing and Asphalt, LLC published installation requirements.
#4 Maximum Design Pressure =-45 mr: I
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Titanium UDL-30 (inverted)
Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, h ads not less than 3/8 inch
diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch
with min. 32 ga.,1-5/8" diameter tin caps I
Spacing: 6-inch D.C. at 4-inchwide side laps and 8-inch o.c. at three (3), equally spaced center rows.
Primer: ASTM D41 primer required at all tin -caps.
Underlayment: One or two plies, Titanium PSU 30, self -adhered and back -nailed 6" o.c. with 12 ga. galvanized
annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens
Corning Roofing and Asphalt, LLC published installation requirements.
#5 Maximum Design Pressure =-45 usf':
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Titanium UDL-30 (printed side up) I
Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch
diameter and length sufficient to penetrate through the thickness of d?ck not less than 3/16-inch
with min. 32 ga.,1-5/8" diameter tin caps.
Spacing: 6-inch o.c. at 4-inch wide side laps and 8-inch o.c at three (3), equally spaced center rows.
Primer: ASTM D41 primer required over printed side of UDL-30.
Underlayment: One or two plies, Titanium PSU 30, self -adhered and back -nailed 6" o.c. with 12 ga. galvanized
annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens
Corning Roofing and Asphalt, LLC published installation requirements. I
5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or
exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or xceed the Zone 1 design
pressure determined in accordance with FBC 1609. Zones 2 and 3 shall employ an attachment density designed by
a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI
WDl, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an
asterisk' carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016)
for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Titanium UDL-25, Titanium UDL-30, Titanium UDL-SO orTrtanium PSU-30 shall not be left exposed for longerthan
180-days.
NEMO ETC, LLC Evaluation Report 111986.11.08-R11
Oe Wf.fe ofA"fhorizarion 432455 6TM EDITION (2017)FaC NON-HVHZ EVALUATION FL11602-R30
Titanium Roof Underlayments Revision 31: 10/17/2M
Page 5 of 8
5.8
6.1
6.2
6.3
6.3.1
6.3.2
*NEM'O I etc.
Tile Slippage Limitations filer FRSA/TRI April 2012 (04-12)1:
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiley.
TABLE 3: TILE SLIPPAGE LIMITATIONS FOR DIRECr-DECK TILE INSTALLATIONS
Underlayment
Tile Profile
Staging Method
Maximum Slope
Titanium PSU-30
Flat
Max. 10-tile stack
5:12
Flat
Max 5-tile stack
6:12
Lugged
Max.10-tile stack
4:12
Lugged
Max. 5-tile stack
5:12
Lugged
Max. 10-tile stack (5 over 51
i
5:12
i
i
Titanium Roof Underlayments shall be installed in accordance with Owens Coming Roofing and Asphalt, LLC
published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted
below.
Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate (if applicable).
TitaniumTM UDL-25,Titanium UDL-30 or Titanium UDL-50:
Shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in FBC Table
1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed, considering the wider sheet -width.
Fasteners:
Mechanical attachment of Titanium UDL-25 and Titanium UDL-30 is limited to ring shank roofing nails with
minimum 1-inch diameter plastic caps. I
Mechanical attachment of Titanium UDL-50 is limitedto ring shank roofing nails with minimum 3/8-inch diameter
heads; ring shank roofing nails with minimum 1-inch diameter plastic caps; screws and pllates; or plastic cap staples.
6.3.2.1 Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 states: '...dreeptmetal cap nailsshall
he required where the ultimate design wind speed, Voui6 equals or exceeds 150 mph."
Owens Coming Roofing and Asphalt, LLC has furnished data to permit the use of 1-inch diameter plastic cap nails
in lieu of metal cap nails for these applications, when the TitaniumTM UDL-25, Titanium UDL-30 or Titanium UDL-50
underlayment is installed beneath mechanically fastened prepared roof covers referenced in FBC Table 1507.1.1
or R905.1.1. J
NEMO ETC, LLC Evaluation Report 111980.1L08-R11
Celhfl a of Authorrzotion#32455 0EDITION (2017)FBC NON-HVHZ EVALUATION I FL11602-RSO
Titanium Roof Underlayments Revision 11: 10/17/2019
Page 6 of 8
NNEMO I etc.
6.3.3 Slopes of 4:12 or greater:
End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 4-inches. End (vertical)
laps shall be offset from course to course not less than 6 feet.
Minimum attachment shall be in accordance with FBCTable 1507.1.1 or R905.1.1. Wh9n batten systems are to be
installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the
battens.
6.3.4 Slopes of 2:12 to less than 4:12:
End (vertical) laps shall be minimum 12-inches and side (horizontal) laps shall be minimum 25-inches. End (vertical)
laps shall be offset from course to course not less than 6 feet.
Begin by fastening a 25-inch wide strip along the eaves. Place afull-width sheet over the starter, completely
overlapping the starter course. Continue upslope, maintaining minimum 25-inch side (horizontal) laps, resulting in
a double -layer application.
Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. Secure end laps 4-inch o.c.
When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily
attached pending attachment of the battens.
6.4 Titanium— PSU-30:
6.4.1 Non -Tile Installations:
Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed, and Owens Cornin� published requirements.
Titanium' PSU-30 shall be back -nailed in accordance with Owens Coming published in allation requirements.
6.4.2 Nail -On Tile Applications:
Shall be installed in compliance with the requirements for Self -Adhered Membrane underlayment set forth in
FRSA/TRI April 2012 (04-12), and Owens Corning published requirements. TitaniumTM' PSU-30 shall be back -nailed
max. 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in
accordance with Owens Corning published installation requirements.
Refer to Section 5.8 for file staging limitations.
6.4.3 Foam -On Tile Applications:
Shall be installed in compliance with the requirements for Self -Adhered Membrane underlayment set forth in
FRSA/TRI April 2012 (04-12), and Owens Corning published requirements. Titanium' PSU-30 shall be back -nailed
max. 6" o.c. with 12 ga, galvanized annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in
accordance with Owens Corning published installation requirements.
Refer to Table 1A for allowable tile adhesives.
Refer to Section 5.6.1 for wind uplift limitations.
Refer to Section 5.8 for file staging limitations.
6.5 Titanium 2-Ply System:
6.5.1 The Titanium 2-Ply System consists of a base layer of Titanium UDL-30 (top -surface primed or sheet inverted)
mechanically attached to the wood roof deck followed by Titanium PSU-30, self -adhered.
6.5.2 Non -Tile Applications:
Install Titanium UDL-30 (top surface primed or sheet inverted) in accordance with Sectiol16.3 followed by Titanipm
PSU-30 in accordance with Section 6.4.
NEMO ETC, LLC Evaluation Report IMSOAL08-1111
Certryhare of AuMortzodap#32A 5 6- EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-R70
Titanium Roof Underlayments Revision 11: 10/17/2019
Page 7 of 9
NNEMO g etc.
6.5.3 Nail -On Tile Applications:
For nail -on tile installations, install Titanium UDL-30 (top surface primed or sheet inverted) in accordance with
FRSA{TRI April 2012 (04-12), using Section 6.3 as a guide, and considering the wider sheet width relative to ASTM
D226 felt. Then apply Titanium PSU-30in accordance with Section 6.4.
Refer to Section 5-8 for tile staging limitations.
6.5.4 Foam -On Tile Applications: Il
For foam -on tile installations, install Titanium UDL-30 (top surface primed or sheet inverted) in accordance with
Section 5.6.1 herein. Then apply Titanium PSU-30 in accordance with Section 6.4
Refer to Table 1A for allowable tile adhesives.
Refer to Section 5.6.1 for wind uplift limitations.
Refer to Section 5.8 for tile staging limitations.
r.. ..�..... s e
As required bythe Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
Contact the manufacturer or the named QA entity for plants covered under Rule 61620-3 QA requirements. Refer
to Section 4 herein for product & production locations having met codified physical properties specifications.
Intertek Testing Services NA Inc. — QUA1673; (604) 520-3321
END OF EVALUATION REPORT -
NEMO ETC, LLC Evil 'on Report IM80.11.08-R31
Cerdfwir of AvthoModon#32455 G" EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-R10
Titanium Roof Undedaymems Revision 11: 10/17/20191
Page 8 of 9