HomeMy WebLinkAboutPeel and Stick Approval and Instructions2/26/20, 7:30 PMFlorida Building Code Online
Page 1 of 3https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqsRyNwiNWDrY8PHC4TwsBEc7W0QGnpkzBcpvKtPYIdHXg%3d%3d
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #FL17322-R5
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer Atlas Roofing Corporation
Address/Phone/Email 2000 RiverEdge Parkway
Suite 800
Atlanta, GA 30328
(770) 946-4571
mcollins@atlasroofing.com
Authorized Signature Meldrin Collins
mcollins@atlasroofing.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
the Evaluation Report
Zachary R. Priest
Florida License PE-74021
Quality Assurance Entity PRI Construction Materials Technologies, LLC.
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Locke Bowden P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence FL17322_R5_COI_ATL14001.5A 2017 FBC Eval Report Atlas
Underlayments final.pdf
Referenced Standard and Year (of Standard)Standard Year
ASTM D 1970 2015
ASTM D 226 2009
ASTM D 2626 2004
2/26/20, 7:30 PMFlorida Building Code Online
Page 2 of 3https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqsRyNwiNWDrY8PHC4TwsBEc7W0QGnpkzBcpvKtPYIdHXg%3d%3d
ASTM D 4869 2016
ASTM D 6380 2003
TAS 103 1995
TAS 110 2000
UL 1897 2012
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 06/15/2019
Date Validated 08/27/2019
Date Pending FBC Approval 06/22/2019
Date Approved 08/28/2019
Summary of Products
FL #Model, Number or Name Description
17322.1 Atlas Underlayments For use in steep slope roofing
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Installation Instructions
FL17322_R5_II_ATL14001.5A 2017 FBC Eval Report Atlas
Underlayments final.pdf
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL17322_R5_AE_ATL14001.5A 2017 FBC Eval Report Atlas
Underlayments final.pdf
Created by Independent Third Party: Yes
17322.2 Fabral All Purpose High-Temp
Underlayment
ASTM D 1970, SBS modified, self-adhering underlayment with
fiberglass mat reinforcement and a poly-fabric surface.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Installation Instructions
FL17322_R5_II_ATL14001.5B 2017 FBC Eval Report Atlas
Fabral Underlayment.pdf
Verified By: Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
Evaluation Reports
FL17322_R5_AE_ATL14001.5B 2017 FBC Eval Report Atlas
Fabral Underlayment.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a
personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter
455, F.S., please click here .
Product Approval Accepts:
2/26/20, 7:30 PMFlorida Building Code Online
Page 3 of 3https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqsRyNwiNWDrY8PHC4TwsBEc7W0QGnpkzBcpvKtPYIdHXg%3d%3d
CREEK
Technical Services, LLC
ATL14001.5A FL17322-R5 Page 1 of 4 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not
specifically addressed herein.
Certificate of Authorization No. 29824
17520 Edinburgh Dr
Tampa, FL 33647
(813) 480-3421
EVALUATION REPORT FLORIDA BUILDING CODE, 6TH EDITION (2017)
Manufacturer: ATLAS ROOFING CORPORATION Issued August 26, 2019
2000 Riveredge Parkway, Suite 800
Atlanta, GA 30328
(770) 612-6267
www.atlasroofing.com
Quality Assurance: PRI Construction Materials Technologies, LLC (QUA9110)
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Sections: 1507.1.1, 1518.4, 1523.1.1, 1523.6.5.2.1
Properties: Physical properties
REFERENCES
Entity Report No. Standard Year
PRI Construction Materials Technologies (TST6049) ATL-033-02-01 ASTM D 226 2009
PRI Construction Materials Technologies (TST6049) ATL-068-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies (TST6049) ATL-068-02-01 ASTM D 4798 2011(2016)
PRI Construction Materials Technologies (TST6049) ATL-068-02-01 TAS 110 2000
PRI Construction Materials Technologies (TST6049) ATL-069-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies (TST6049) ATL-090-02-01 TAS 103 1995
PRI Construction Materials Technologies (TST6049) ATL-149-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies (TST6049) ATL-164-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies (TST6049) ATL-254-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies (TST6049) ATL-255-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies (TST6049) BWR-533-02-01 TAS 103 1995
PRI Construction Materials Technologies (TST6049) BWR-543-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies (TST6049) MSA-004-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies (TST6049) MSA-007-02-01 UL 1897 2012
PRI Construction Materials Technologies (TST6049) MSA-026-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies (TST6049) WRMI-011-02-01 ASTM 1970 2015a
PRI Construction Materials Technologies (TST6049) MSA-007-02-01 UL 1897 2012
PRI Construction Materials Technologies (TST6049) MSA-030-02-01 ASTM D 1970 2015a
UL LLC (TST1740) 02-NK40952 ASTM D 1970 2015a
UL LLC (TST1740) 02-NK40952 ASTM D 226 2009
UL LLC (TST1740) 02-NK40952 ASTM D 2626 2004(2012)E1
UL LLC (TST1740) 02-NK40952 ASTM D 4869 2016
UL LLC (TST1740) 02-NK40952 ASTM D 6380 2003 (2013)
A CREEK
Technical Services, LLC
ATL14001.5A FL17322-R5 Page 2 of 4 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product at tributes that are not
specifically addressed herein.
ATLAS ROOFING CORPORATION
Roofing Underlayments
PRODUCT DESCRIPTION
#15 Specification Felt ASTM D 226, Type I asphalt saturated organic felt underlayment for use in the
HVHZ and non-HVHZ.
#30 Organic Saturated Felt ASTM D 4869, Type II asphalt saturated organic felt underlayment for use in the
non-HVHZ only.
#30 Specification Felt ASTM D 226, Type II asphalt saturated organic felt underlayment for use in the
HVHZ and non-HVHZ.
#43 Base Sheet ASTM D 2626 asphalt saturated and coated, non-perforated, organic felt
underlayment for use in the HVHZ and non-HVHZ.
#90 Mineral Surface Roll
Roofing
ASTM D 6380, Class M asphalt-saturated organic roll roofing sheet for use in the
HVHZ and non-HVHZ.
Gorilla Guard® EVERFELT 30 Asphalt-saturated organic felt underlayment reinforced with glass fiber that meets
the performance requirements of ASTM D 226, Type I for use in the HVHZ and
non-HVHZ.
Slate/Tile Underlayment ASTM D 6380, Class M asphalt-saturated organic roll roofing sheet for use in the
HVHZ and non-HVHZ.
WeatherMaster® Ice and
Water 100
ASTM D 1970 SBS modified, self-adhering underlayment reinforced with a
fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The
self-adhesive side is covered with a release film, which is removed during
installation.
WeatherMaster® Ice and
Water 200
ASTM D 1970 SBS modified, self-adhering underlayment reinforced with a
fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The
self-adhesive side is covered with a split-release film, which is removed during
installation.
WeatherMaster® Ice and
Water 216
ASTM D 1970 SBS modified, self-adhering underlayment reinforced with a
fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The
self-adhesive side is covered with a split-release film, which is removed during
installation.
WeatherMaster® Flexible Ice
and Water
ASTM D 1970 SBS modified, self-adhering underlayment with plastic film surface
for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a
split-release film, which is removed during installation.
WeatherMaster® Pro-Grade
Ice and Water
ASTM D 1970 SBS modified, self-adhering underlayment with a fiberglass mat
reinforcement and a poly-fabric surface for use in the HVHZ and non-HVHZ. The
self-adhesive side is covered with a release film, which is removed during
installation.
WeatherMaster® Tile TAS 103 SBS modified, self-adhering underlayment with a fiberglass mat
reinforcement and a poly-fabric surface for use in the HVHZ and non-HVHZ. The
self-adhesive side is covered with a release film, which is removed during
installation.
A CREEK
Technical Services, LLC
ATL14001.5A FL17322-R5 Page 3 of 4 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product at tributes that are not
specifically addressed herein.
ATLAS ROOFING CORPORATION
Roofing Underlayments
APPLICATION METHOD
Installation shall be in accordance with the published manXfacWXUeU¶V inVWallaWion inVWUXcWionV, Whe FBC, and Whe
requirements below.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be
checked for protrusion and corrected prior to underlayment application.
The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck
shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8´ gap at abutting
joints.
Exposure of the underlayments shall be limited to a maximum 30 days except as follows:
a) #15 Specification Felt, #30 Specification Felt, and #40 Base Sheet – exposure for greater than 24 hours
may adversely affect product performance
b) WeatherMaster® Ice and Water 100, WeatherMaster® Ice and Water 200, WeatherMaster® Ice and
Water 216, WeatherMaster® Pro-Grade Ice, and WeatherMaster® Tile – maximum 90 days
Self-adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ.
Roof coverings shall be mechanically fastened through the underlayment to the roof deck except as follows (or as
indicated in other current FBC product approval documents):
a) WeatherMaster® Pro-Grade Ice and Water or WeatherMaster® Tile – ICP Adhesives Polyset AH-160
b) Slate/Tile Underlayment or #90 Mineral Surface Roll Roofing – Convenience Products Touch n¶ Seal
StormBond Roof Tile Adhesive, Dow TileBond, or ICP Adhesives Polyset AH-160
Allowable Roof Coverings:
Underlayment
Asphalt
Shingles
Metal Roof
Panels and
Shingles
Composite or
Photovoltaic
Shingles
Wood
Shingles and
Shakes
Slate
Shingles
Clay and
Concrete Tile
#15 Specification Felt Y Y Y Y2 Y N
#30 Organic Saturated Felt Y Y Y Y Y N
#30 Specification Felt Y Y Y Y Y Y
#43 Base Sheet Y Y Y N Y Y
#90 Mineral Surface Roll Roofing Y1 N N N N Y
Gorilla Guard® EVERFELT 30 Y Y Y Y2 Y N
Slate/Tile Underlayment Y1 N N N N Y
WeatherMaster® Ice and Water
100 Y Y Y N Y N
WeatherMaster® Ice and Water
200 Y Y Y N Y N
WeatherMaster® Ice and Water
216 Y Y Y N Y N
WeatherMaster® Flexible Ice and
Water Y Y Y N Y N
WeatherMaster® Pro-Grade Ice
and Water Y Y Y N Y N
WeatherMaster® Tile Y Y Y N Y Y
Notes: 1) Open valley applications per 1507.2.9.2
2) Wood shingles only
A CREEK
Technical Services, LLC
ATL14001.5A FL17322-R5 Page 4 of 4 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
ATLAS ROOFING CORPORATION
Roofing Underlayments
WIND RESISTANCE (NON-HVHZ ONLY)
The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9.
Underlayment System No.1 – WeatherMaster® Tile only
Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24´ o.c.
Underlayment: WeatherMaster® Tile shall be fully adhered to the optionally primed plywood deck.
Maximum Design
Pressure:
-52.5 psf
LIMITATIONS
1)Fire Classification is not within the scope of this evaluation.
2)Roof slope limitations shall be in accordance with FBC requirements.
3)Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer¶s published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4)Products described within this report may be used as described in other current FBC product approval
documents.
5)Roof coverings shall not be adhered directly to the underlayment unless otherwise approved in this or other
current FBC product approval documents.
6)All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest P.E. have demonstrated compliance with the Florida Building
Code, 6th Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
2019.08.26
15:33:08