Loading...
HomeMy WebLinkAboutPeel and Stick Approval and Instructions2/26/20, 7:30 PMFlorida Building Code Online Page 1 of 3https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqsRyNwiNWDrY8PHC4TwsBEc7W0QGnpkzBcpvKtPYIdHXg%3d%3d BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL17322-R5 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Atlas Roofing Corporation Address/Phone/Email 2000 RiverEdge Parkway Suite 800 Atlanta, GA 30328 (770) 946-4571 mcollins@atlasroofing.com Authorized Signature Meldrin Collins mcollins@atlasroofing.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Zachary R. Priest Florida License PE-74021 Quality Assurance Entity PRI Construction Materials Technologies, LLC. Quality Assurance Contract Expiration Date 12/31/2020 Validated By Locke Bowden P.E. Validation Checklist - Hardcopy Received Certificate of Independence FL17322_R5_COI_ATL14001.5A 2017 FBC Eval Report Atlas Underlayments final.pdf Referenced Standard and Year (of Standard)Standard Year ASTM D 1970 2015 ASTM D 226 2009 ASTM D 2626 2004 2/26/20, 7:30 PMFlorida Building Code Online Page 2 of 3https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqsRyNwiNWDrY8PHC4TwsBEc7W0QGnpkzBcpvKtPYIdHXg%3d%3d ASTM D 4869 2016 ASTM D 6380 2003 TAS 103 1995 TAS 110 2000 UL 1897 2012 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 06/15/2019 Date Validated 08/27/2019 Date Pending FBC Approval 06/22/2019 Date Approved 08/28/2019 Summary of Products FL #Model, Number or Name Description 17322.1 Atlas Underlayments For use in steep slope roofing Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. Installation Instructions FL17322_R5_II_ATL14001.5A 2017 FBC Eval Report Atlas Underlayments final.pdf Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports FL17322_R5_AE_ATL14001.5A 2017 FBC Eval Report Atlas Underlayments final.pdf Created by Independent Third Party: Yes 17322.2 Fabral All Purpose High-Temp Underlayment ASTM D 1970, SBS modified, self-adhering underlayment with fiberglass mat reinforcement and a poly-fabric surface. Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. Installation Instructions FL17322_R5_II_ATL14001.5B 2017 FBC Eval Report Atlas Fabral Underlayment.pdf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL17322_R5_AE_ATL14001.5B 2017 FBC Eval Report Atlas Fabral Underlayment.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: 2/26/20, 7:30 PMFlorida Building Code Online Page 3 of 3https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqsRyNwiNWDrY8PHC4TwsBEc7W0QGnpkzBcpvKtPYIdHXg%3d%3d CREEK Technical Services, LLC ATL14001.5A FL17322-R5 Page 1 of 4 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 33647 (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 6TH EDITION (2017) Manufacturer: ATLAS ROOFING CORPORATION Issued August 26, 2019 2000 Riveredge Parkway, Suite 800 Atlanta, GA 30328 (770) 612-6267 www.atlasroofing.com Quality Assurance: PRI Construction Materials Technologies, LLC (QUA9110) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1507.1.1, 1518.4, 1523.1.1, 1523.6.5.2.1 Properties: Physical properties REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST6049) ATL-033-02-01 ASTM D 226 2009 PRI Construction Materials Technologies (TST6049) ATL-068-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) ATL-068-02-01 ASTM D 4798 2011(2016) PRI Construction Materials Technologies (TST6049) ATL-068-02-01 TAS 110 2000 PRI Construction Materials Technologies (TST6049) ATL-069-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) ATL-090-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST6049) ATL-149-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) ATL-164-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) ATL-254-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) ATL-255-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) BWR-533-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST6049) BWR-543-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) MSA-004-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) MSA-007-02-01 UL 1897 2012 PRI Construction Materials Technologies (TST6049) MSA-026-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) WRMI-011-02-01 ASTM 1970 2015a PRI Construction Materials Technologies (TST6049) MSA-007-02-01 UL 1897 2012 PRI Construction Materials Technologies (TST6049) MSA-030-02-01 ASTM D 1970 2015a UL LLC (TST1740) 02-NK40952 ASTM D 1970 2015a UL LLC (TST1740) 02-NK40952 ASTM D 226 2009 UL LLC (TST1740) 02-NK40952 ASTM D 2626 2004(2012)E1 UL LLC (TST1740) 02-NK40952 ASTM D 4869 2016 UL LLC (TST1740) 02-NK40952 ASTM D 6380 2003 (2013) A CREEK Technical Services, LLC ATL14001.5A FL17322-R5 Page 2 of 4 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product at tributes that are not specifically addressed herein. ATLAS ROOFING CORPORATION Roofing Underlayments PRODUCT DESCRIPTION #15 Specification Felt ASTM D 226, Type I asphalt saturated organic felt underlayment for use in the HVHZ and non-HVHZ. #30 Organic Saturated Felt ASTM D 4869, Type II asphalt saturated organic felt underlayment for use in the non-HVHZ only. #30 Specification Felt ASTM D 226, Type II asphalt saturated organic felt underlayment for use in the HVHZ and non-HVHZ. #43 Base Sheet ASTM D 2626 asphalt saturated and coated, non-perforated, organic felt underlayment for use in the HVHZ and non-HVHZ. #90 Mineral Surface Roll Roofing ASTM D 6380, Class M asphalt-saturated organic roll roofing sheet for use in the HVHZ and non-HVHZ. Gorilla Guard® EVERFELT 30 Asphalt-saturated organic felt underlayment reinforced with glass fiber that meets the performance requirements of ASTM D 226, Type I for use in the HVHZ and non-HVHZ. Slate/Tile Underlayment ASTM D 6380, Class M asphalt-saturated organic roll roofing sheet for use in the HVHZ and non-HVHZ. WeatherMaster® Ice and Water 100 ASTM D 1970 SBS modified, self-adhering underlayment reinforced with a fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a release film, which is removed during installation. WeatherMaster® Ice and Water 200 ASTM D 1970 SBS modified, self-adhering underlayment reinforced with a fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a split-release film, which is removed during installation. WeatherMaster® Ice and Water 216 ASTM D 1970 SBS modified, self-adhering underlayment reinforced with a fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a split-release film, which is removed during installation. WeatherMaster® Flexible Ice and Water ASTM D 1970 SBS modified, self-adhering underlayment with plastic film surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a split-release film, which is removed during installation. WeatherMaster® Pro-Grade Ice and Water ASTM D 1970 SBS modified, self-adhering underlayment with a fiberglass mat reinforcement and a poly-fabric surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a release film, which is removed during installation. WeatherMaster® Tile TAS 103 SBS modified, self-adhering underlayment with a fiberglass mat reinforcement and a poly-fabric surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a release film, which is removed during installation. A CREEK Technical Services, LLC ATL14001.5A FL17322-R5 Page 3 of 4 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product at tributes that are not specifically addressed herein. ATLAS ROOFING CORPORATION Roofing Underlayments APPLICATION METHOD Installation shall be in accordance with the published manXfacWXUeU¶V inVWallaWion inVWUXcWionV, Whe FBC, and Whe requirements below. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8´ gap at abutting joints. Exposure of the underlayments shall be limited to a maximum 30 days except as follows: a) #15 Specification Felt, #30 Specification Felt, and #40 Base Sheet – exposure for greater than 24 hours may adversely affect product performance b) WeatherMaster® Ice and Water 100, WeatherMaster® Ice and Water 200, WeatherMaster® Ice and Water 216, WeatherMaster® Pro-Grade Ice, and WeatherMaster® Tile – maximum 90 days Self-adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ. Roof coverings shall be mechanically fastened through the underlayment to the roof deck except as follows (or as indicated in other current FBC product approval documents): a) WeatherMaster® Pro-Grade Ice and Water or WeatherMaster® Tile – ICP Adhesives Polyset AH-160 b) Slate/Tile Underlayment or #90 Mineral Surface Roll Roofing – Convenience Products Touch n¶ Seal StormBond Roof Tile Adhesive, Dow TileBond, or ICP Adhesives Polyset AH-160 Allowable Roof Coverings: Underlayment Asphalt Shingles Metal Roof Panels and Shingles Composite or Photovoltaic Shingles Wood Shingles and Shakes Slate Shingles Clay and Concrete Tile #15 Specification Felt Y Y Y Y2 Y N #30 Organic Saturated Felt Y Y Y Y Y N #30 Specification Felt Y Y Y Y Y Y #43 Base Sheet Y Y Y N Y Y #90 Mineral Surface Roll Roofing Y1 N N N N Y Gorilla Guard® EVERFELT 30 Y Y Y Y2 Y N Slate/Tile Underlayment Y1 N N N N Y WeatherMaster® Ice and Water 100 Y Y Y N Y N WeatherMaster® Ice and Water 200 Y Y Y N Y N WeatherMaster® Ice and Water 216 Y Y Y N Y N WeatherMaster® Flexible Ice and Water Y Y Y N Y N WeatherMaster® Pro-Grade Ice and Water Y Y Y N Y N WeatherMaster® Tile Y Y Y N Y Y Notes: 1) Open valley applications per 1507.2.9.2 2) Wood shingles only A CREEK Technical Services, LLC ATL14001.5A FL17322-R5 Page 4 of 4 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ATLAS ROOFING CORPORATION Roofing Underlayments WIND RESISTANCE (NON-HVHZ ONLY) The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9. Underlayment System No.1 – WeatherMaster® Tile only Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24´ o.c. Underlayment: WeatherMaster® Tile shall be fully adhered to the optionally primed plywood deck. Maximum Design Pressure: -52.5 psf LIMITATIONS 1)Fire Classification is not within the scope of this evaluation. 2)Roof slope limitations shall be in accordance with FBC requirements. 3)Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer¶s published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4)Products described within this report may be used as described in other current FBC product approval documents. 5)Roof coverings shall not be adhered directly to the underlayment unless otherwise approved in this or other current FBC product approval documents. 6)All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest P.E. have demonstrated compliance with the Florida Building Code, 6th Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT 2019.08.26 15:33:08 -04'00'