1. THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING, AND
BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY
SET -BACKS, FINISH FLOOR ELEVATION AND SLOPE, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS.
2. THIS STRUCTURE IS DESIGNED AS A NON -HABITABLE UTILITY/STORAGE BUILDING (RISK CATEGORY 1) CAPABLE OF SUPPORTING DEAD
LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN, INCLUDING
DOORS, WINDOWS, OR OTHER COMPONENTS NOT LISTED IN THE FBC APPROVED PRODUCTS LIST, AND NOT PROVIDED AND INSTALLED
BY CARPORTS ANYWHERE, INC., WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE AT THE OWNER'S RISK. CARPORTS
ANYWHERE NOR THE ENGINEERING DESIGN SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE
APPLICATION OF ADDITIONAL LOADS.
3. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION C101.4.2.
4. ALL STEEL TUBING SHALL BE 50 KSI STEEL AND MEETS/EXCEEDS GALVANIZATION PER ASTM A1003/A1003M-15.
5.PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET -BACKS, AND/OR OTHER LOCAL CODE REQUIREMENTS ARE THE
RESPONSIBILITY OF THE OWNER.
6. ROOF AND WALL SHEATHING SECURED WITH #12-14x1" SELF -DRILLING SCREWS WITH SEAL WASHERS ® 6" O.C. MAX.
7. FIELD FRAMING CONNECTIONS SECURED WITH #12-143/4" SELF -DRILLING SCREWS,
8. ALL SHOP FRAMING CONNECTIONS ARE TO BE WELDED. NO WELDING ONSITE. ALL WELDING DONE IN SHOP.
9. CONCRETE EXPANSIONS ANCHORS ARE TO BE MINIMUM 1/2" DIAMETER & 2,50OLB TENSILE STRENGTH.
10. 12 GA. FRAMING IS 2.5"x2.5" TUBE STEEL. NIPPLES ARE 2.25"x2.25" TUBE STEEL.
SUB -GRADE SOILS:
-TO BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDANT PER SECTION
R318 AND 1816 OF THE 2017 FLORIDA BUILDING CODE, 6TH EDITION
CONCRETE:
-MINIMUM 2,500 PSI COMPRESSIVE STRENGTH AT 28 DAYS
-ALL OPEN AREAS OF CONCRETE OUTSIDE OF THE PROPOSED STRUCTURE SHALL BE
DESIGNED TO SLOPE AWAY FROM THE STRUCTURE
REINFORCING STEEL (REBAR) REQUIREMENTS:
-MINIMUM GRADE 40 STEEL
-REBAR MAY BE BENT IN SHOP OR FIELD PROVIDED:
-THE REBAR IS BENT COLD
-THE DIAMETER OF THE BEND MEASURED ON THE INSIDE DOES NOT EXCEED
6-BAR DIAMETERS: AND
-REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT
EXCEPT IN CASES WHERE DOWELS NEED TO BE BENT TO ALIGN WITH A VERTICAL
CELL. THESE REBAR MAY BE BENT NOT TO EXCEED TO SLOPE OF 1"
HORIZONTALLY TO 6" VERTICALLY.
-COVER:
-2" COVER MINIMUM WHERE THE CONCRETE IS CAST AGAINST AND PERMANENTLY
IN CONTACT WITH SOIL OR WEATHER, AND 14" ELSEWHERE. REBAR EMBEDDED IN
GROUTED CELLS SHALL HAVE A MINIMUM CLEAR DISTANCE OF #" FOR FINE
GROUT, AND 4" FOR COARSE GROUT BETWEEN REBAR AND ANY FACE OF A CELL.
REBAR USED IN MASONRY WALLS SHALL HAVE A MASONRY COVER (INCLUDING
GROUT) OF NOT LESS THAN 2" FOR MASONRY UNITS WITH FACE EXPOSED TO
EARTH OR WEATHER, AND 1j" FOR MASONRY UNITS NOT EXPOSED TO EARTH OR
WEATHER.
GALVANIZATION:
-METAL ACCESSORIES FOR USE IN EXTERIOR WALL CONSTRUCTION AND NOT DIRECTLY
EXPOSED TO WEATHER SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A 153,
CLASS B-2. METAL PLATE CONNECTORS, SCREWS, BOLTS, AND NAILS EXPOSED
DIRECTLY TO WEATHER SHALL BE STAINLESS STEEL OR HOT DIPPED GALVANIZED.
---- Rni i—JJP-----
DOOR
0'
MIN. 2,500 PSI 4" CONCRETE SLAB WITH W.W.F. (OR FIBER
MESH) AND 12"x12" REINFORCED FOOTER PERIMETER 12"02
M
J"x5j" EXPANSION ANCHOR WITHIN 6"
OF EACH POST/TRUSS ALONG SIDES
AND EVERY OTHER END -WALL POST
2" MIN.—i 4 .-BASE RAIL
F--12"—
MINIMUM SOIL BEARING
CAPACITY 2,000 PSF(TYP.)
Z 2,500 PSI 4"
CONCRETE SLAB
W.W.F. OR FIBER
(2) #5 REBAR ® 6" O.C.
CONTINUOUS WITH MINIMUM
12" OVERLAP SPLICE
CONCRETE FOUNDATION/BASE RAIL
ANCHOR DETAIL
2 5" PLAN VIEW DOOR FRAMING
" RECESS
4 DOOR WIDTII
ELEVATION VIEW
DOOR FRAMING
" RECESS
.75"T 4OOR WIDT
"
OPTIONAL ROLL -UP DOOR
CONCRETE SPLASH -GUARD RECESS
_ED FOOTER
11
0
in
N
CAMIM
CODE INFORMATION
CODE VERSION rBC 2017 6th Edition
MANUFACTURER
CARPORTS ANYWHERE
BUILDING TYPE
UTILITY STRUCTURE
CONSTRUCTION TYPE
II-B
RISK CATEGORY
I
FIRE PROTECTION
NONE
FIRE SUPPRESSION SYSTEM
NONE
OCCUPANCY
UTILITY, U
WIND SPEED
Vult-165mph
ENCLOSURE
PARTIALLY ENCLOSED
INTERNAL PRESSURE COEFF.
+/- 0,55
IMPORTANCE FACTOR
1.0
ROOF DEAD LOAD
1OPSF
ROOF LIVE LOAD
20PSF OR 3001b P.L.
FLOOR DEAD LOAD
10PSF
FLOOR LIVE LOAD
50PSF
"R"RATING OF WALLS, FLOOR, ROOF
N/A
MODULES PER BUILDING
1
HURRICANE PROTECTION USAGE
NO
HURRICANE SHELTER USAGE
NO
SQUARE FOOTAGE
1,650 SQ. Fr.
REVISIONS
RFV
DESCRIPTON
DATE
BY
MTB
3/8/20
Hammock Lane., Pt. St. Lucie
1 55'L X 30'W X 12'H 11
Li 3,/g'/2.011,,.
Z MattheW T. BaldWin P.E.
Q Florida License #64608
6.i J
F Sheet: CA-1 OF 4
12
3�
-0'-
FRAME
OUT
FRONT END WALL
SWINGING
DOOR
ROLL -UP
DOOR
' O.C. MAX.
10'-0.
0
I
0
ROLL -UP
DOOR
—o'
1 -7a'
3'-10
3'-1 "'
3'-1 '
3'-10,-�'n
3'-10
3'-10
O.C.
LEFT SIDE WALL
RIGHT SIDE WALL
-1 oR I 3'-1 oW' -I 3'-
}
CODE VERSION fBC 2017 6th Edition�j
BUILDING TYPE
UTILITY STRUCTURE
CONSTRUCTION TYPE
II—B
RISK CATEGORY
I
FIRE PROTECTION
NONE
FIRE SUPPRESSION SYSTEM
NONE
OCCUPANCY
UTILITY, U
WIND SPEED
Vult-165mph
ENCLOSURE
PARTIALLY ENCLOSED
INTERNAL PRESSURE COEFF.
+/— 0.55
IMPORTANCE FACTOR
1.0
ROOF DEAD LOAD
1OPSF
ROOF LIVE LOAD
20PSF OR 3001b P.L.
FLOOR DEAD LOAD
1OPSF
FLOOR LIVE LOAD
50PSF
"R"RATING OF WALLS, FLOOR, ROOF
N/A
MODULES PER BUILDING
1
HURRICANE PROTECTION USAGE
NO
HURRICANE SHELTER USAGE
NO
SQUARE FOOTAGE
1,650 SQ. FT.
REVISIONS
MTB
3/8/20
Hammock Lane., Pt. St. Lucie
55'L X 30'W X 12'H
`C L)
W
.3 9 2C�
Matthew 7. BaldWin P.E.
W
Florida License #64608
Cn
Sheet:
CA-2 OF 4
FRAME
OUT
ONT END
LEFT SIDE WALL
RIGHT SIDE WALL
SWINGING
DOOR
REAR END WALL
CODE VERSION
MANUFACTURER
BUILDING TYPE
CONSTRUCTION TYPE
RISK CATEGORY
0
FIRE PROTECTION
iV
FIRE SUPPRESSION
OCCUPANCY
WIND SPEED
-tju zu I i otn taltlon
NSCE-7-10
:ARPORTS ANYWHERE
JTILITY STRUCTURE
I—B
I
LITY, U
t-165mph
ENCLOSURE
PARTIALLY ENCLOSED
INTERNAL PRESSURE COEFF.
+/— 0.55
IMPORTANCE FACTOR
1.0
ROOF DEAD LOAD
1OPSF
ROOF LIVE LOAD
0PSF OR 3001b P.L.
FLOOR DEAD LOAD
1OPSF
FLOOR LIVE LOAD
50PSF
"R"RATING OF WALLS, FLOOR, ROOF
N/A
MODULES PER BUILDING
1
HURRICANE PROTECTION USAGE
NO
HURRICANE SHELTER USAGE
NO
SQUARE FOOTAGE
1,650 SQ. FT,
REVISIONS
MTB
3/8/20
Hammock Lane., Pt. St. Lucie
55'L X 30'W X 12'H
U.
w
LLJ
Matthew T. Baldwin P.E.
LLJ
Florida License #64608
4i (—)
(�
Sheet: CA-3 OF4
MINIMUM 6" TS NIPPLE. NIPPLE
SECURED TO WALL POST WITH
SCREWS #12-14,j- SELF —DRILLING
NIPPLE TO
V \ BASE RAIL
POST TO BASE RAIL
CONNECTION
NIPPLE T
BASE RAI
MINIMUM 6" TS NIPPLE. NIPPLE
SECURED TO WALL POST WITH
SCREWS 14xj" SELF —DRILLING
2"x2"x2" 16 GA. ANGLE CLIP
SECURED WITH (4) #12-14xi"
SELF —DRILLING SCREWS
END POST TO BASE RAIL
CONNECTION
2"x2"x2" 16 GA. ANGLE CLIP
SECURED WITH (4) #12-14xi"
SELF —DRILLING SCREWS
NON—STRUCTURAL HEADER OR
WINDOW RAIL TO POST DETAIL
INTERIOR
#12-144" SELF —DRILLING
SCREWS ® 10" O.C. MAX.,
3" MAX. FROM CORNERS
HORIZONTALLY/ 4" MAX.
FROM CORNERS VERTICALL'
EXTERIOR
DOOR FRAME TO POST
CONNECTION
18„
Ir
2"x2"x2" 16 GA. ANGLE CLIP
SECURED WITH (4) #12-14xj"
SELF —DRILLING SCREWS
INTERMEDIATE POST TO
HEADER/BASE RAIL/OR
WINDOW RAIL DETAIL
2"x2"x2" 15 GA. ANGLE CLIP SECURED
WITH (4) #12-14xi" SELF —DRILLING
SCREWS
SIDE WALL ROLL —UP
DOOR/FRAME OUT
HEADER DETAIL
INSTALL PER MANUFACTURERS INSTRUCTIONS
#140" SELF —DRILLING
SCREWS ® 6" O.C. MAX.
& 6" MAX. FROM CORNERS
ROLL —UP DOOR TO
POST CONNECTION
DESIGN PRESSURES
— 165 Mph
ROOF
+27.8/-62.5
WALLS
+32.5/-35.2
DOORS
+32.5/-35.2
WINDOWS
+32.5/-35.2
1
2
3
4
5
ZONE
+17.3
—24.9
+20.4
—48.3
+27.8
—62.5
+30.9
—33.1
+32.5
—35.2
2"x2"x2" 16 GA. ANGLE CLIP
SECURED WITH (4) #12-14xi"
SELF —DRILLING SCREWS
SINGLE OR DOUBLETS
HEADER
HEADER CONNECTION
DETAIL OPTION 1
26 GAUGE ROOF SHEATHING SECURED WITH
(1)#12-14xj" SELF —DRILLING SCREWS
'2-1-2-1' (6" O.C. (9" O.C. MAX.))
._ AIPPLE TO
1" 16 GAUGE FURRING CHANNEL
48" O.C. MAX. SECURED WITH
(2)#12-14x1" SELF —DRILLING
SCREWS TO EACH RAFTER.
ROOF PANEL CONNECTION
VERTICAL SHEATHING OPTION
16 GA. U—CHANNEL
BRACE, MIN. 24" UP TO
7' POST, MIN. 48" OVEF
7' POST. MIN. 45' TO
MAX. 60' FROM HORIZ.
(EXCLUDE END —WALLS)
MINIMUM 6" TS NIPPLE. NIPPLE
SECURED TO WALL POST WITH
(4)#12-14xi" SELF —DRILLING
SCREWS
BOX EAVE RAFTER TO
POST CONNECTION DETAIL
NIPPLE
MINIMUM 6" TS NIPPLE. NIPPLE
SECURED TO WALL POST WITH r„ ,i �� i ���
SCREWS 14x "SELF —DRILLING (�.f1�7 �LL7rIr
SINGLE OR DOUBLETS
HEADER CONNECTION DETAIL
OPTION 2
TO
TRUSSED RAFTER
CONNECTION DETAIL
MINIMUM 6" TS NIPPLE.
NIPPLE SECURED TO WALL
POST WITH (4)#12-14x4"
SELF —DRILLING SCREWS
POST TO TRUSS
CONNECTION
APPROVED PRODUCTS
APPROVAL NO.
ROOF SHEATHING
Carports Anywhere
FL274O2.1 —R1
Hampton Rib Roof Panel
WALL SHEATHING
Carports Anywhere
FL274O3.1
Hampton Rib Wall Panel
SWINGING DOOR
ELIXER DOOR AND METAL COMPANY
FL17996.5
407 STEEL DOOR
ROLL —UP DOOR
JANUS INTERNATIONAL CORPORATION
FL12765.3—R5
SERIES 3100
CODE VERSION IFBC 2017 6th Edition,ll
ecrr,_7_1n
BUILDING TYPE
UTILITY STRUCTURE
CONSTRUCTION TYPE
II—B
RISK CATEGORY
I
FIRE PROTECTION
NONE
FIRE SUPPRESSION SYSTEM
NONE
OCCUPANCY
UTILITY, U
WIND SPEED
Vult-165mph
ENCLOSURE
PARTIALLY ENCLOSED
INTERNAL PRESSURE COEFF.
+/— 0.55
IMPORTANCE FACTOR
1.0
ROOF DEAD LOAD
1OPSF
ROOF LIVE LOAD
20PSF OR 3001b P.L.
FLOOR DEAD LOAD
10PSF
FLOOR LIVE LOAD
50PSF
"R"RATING OF WALLS, FLOOR, ROOF
N/A
MODULES PER BUILDING
1
HURRICANE PROTECTION USAGE
NO
HURRICANE SHELTER USAGE
NO
SQUARE FOOTAGE
1,650 SQ. FT.
REVISIONS
DATE:
MTB
3/8/20
Hammock Lane., Pt. St. Lucie
55'L X 30'W X 12'H I�
Matthew T. Baldwin P.E.
Florida License #54608
Sheet: CA-4 OF 4