Loading...
HomeMy WebLinkAboutproduct approval, eng details , section c low slope systemFlorida Building Code 2010 Edition High Velocity Hurricane Zone Uniform permit Application Form Section C (Low Slowed Roof System) Fill in Specific Roof Assembly Components Fastener Spacing for Anchor/Base Sheet and Identify Manufacturer Attachment (If a component is not used, identify as "NA") Field: —"oc @ Lap, # Rows @ " oc System Manufacturer., Perimeter: " oc @ Lap, # Rows _ @ " oc NOA No.: Comer. —'oc; @ Lap, # Rows " oc Design Wind Pressures, From RAS 128 or Calculations: Number of Fasteners Per Insulation Pmax1: Pmax2: Pmax3: Board Max. Design Pressure, From the Specific NOA System: Field Deck: Type: Gauge/Thickness: Slope: Anchor/Base Sheet & No. of Ply(s): Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer: Base Insulation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Material: Ply Sheet(s) A No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Top Ply Fastener/ Bonding Material: Surfacing: Perimeter Corner Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter- Flashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. 6 r4AIC=_� � c 7:�J� March 23rd, 2020 Mr. Tom Burnett Florida Home Improvement 3044 SW 42°d Street Fort Lauderdale, FL 33312 SPECIALTY ENGINEERING CONSULTANTS, Inc. DADE - BROWARD - PALM BEACH Re: 8608 PENNY LANE, FORT PIERCE, FL 34951-1035 [10562611 STRUCTURAL REVIEW OF ENHANCED NAILING REQUIRMENT Dear Mr. Burnett: Pursuant to your request we have reviewed the enhanced nailing required for the flat roof membrane installation at the referenced home. Our findings are as follows. Wind Design Criteria: V=170 mph (3 second gust), Exposure C, Risk Category 2. From the Florida Building Code, RAS 128: P,,d1:42.8 psf, P d2:71.7 psf, P,d3:108.0 psf Using NOA 18-1127.18 CertainTeed Corporation the maximum pressure using E(3) is -52.5 psf. The base sheet is installed 8" on center along the 4" wide side lap and then 3 additional rows staggered, 8" on centered. The tributary area per fastener is 8x11=88 square inches. (4 additional rows staggered, 8" on center for>125% fasting) The field nailing (zone 1) is acceptable since 52.5<60. Use a spacing of 8" on center for zone 1 Next check zone 2: 52.5171.7 * 8" o/c = 5.86" spacing. Use a spacing of 5" on center for zone 2. Next check zone 3: 52.5/108 * 8" o/c = 3.89" *1.25 = 4.86" spacing. Use a spacing of 4" on center for zone 3. There is (1) flat roof area, (Al) 8'x 51' The end zone distance is 10%Ll OR 10%L2, or 40% Mean roof height, whichever is smaller, but not less than 3 feet - 3.7' or 5.1' or 6.0' thus 3.7' governs. The (Al) will have a 4' wide by 4' long zone 3 at the corners. Zone 2 will consist of the remainder of the 8' x 51' area not specified as Zone 3. Please refer to the next page for clarification of designated Zone 2 Area. We hope that you find this information helpful and should you have any questions please feel free to call on us. ,t`I`y1j1111111111111I1rl/��fi Respectfully submitted � A4 Specialty Engineering Consultants, . Z 1 0.77012 Cy MaR3zo2 .o STAT D. Adam LeBlanc, PE Vice President of Design 'y%S'ONAI '"1111110 II,d1 State of Florida: Registered Professiona Engineer: #0077012 Certificate of Authorization: #009217 Ian Harrington Project Engineer 1599 SW 30d' Avenue, Suite 20 . Boynton Beach, FL 33426 - Office: 561-752-5440 - Fax: 561-752-5542 SPECIALTY ENGINEERING CONSULTANTS, Inc. DADE - BROWARD - PALM BEACH Flat Roof Zones N 6 ,11,1111l FFFFII _—No. 77012 C) " * MAR 2020 ,Q STATE ' `���rfltFFrrFFittFFFti�� 1599 SW 30'h Avenue, Suite 20 Boynton Beach, FL 33426 Office: 561-752-5440 - Fax: 561-752-5542 CLIENT INFORMATION FLORIDA HOME IMPROVEMENT 3044 SW 42nd STREET FORT LAUDERDALE, FL 33312 PROJECT INFORMATION TYPICAL FLAT ROOF (ENHANCED) UNDERLAYMENT LAPS GTA SYSTEM AND NAIL/TINCAP PLACEMENT (NOA 18-1127.18) 6" ENDLAP 0 O SPECIALTY ENGINEERING CONSULTANTS, Inc N uI SW 30th AVE. SUITE20 BOY BEACH, FL 33426 DADE - BROWARD - PALL BEACH FL. CA. #009217 561 - 752 - 5440 OFRCE 561 - 752 - 5542 FAX ROOF UNDERLAYMENTS PER NOA. a W a , 0. 0— o O 0 0 0 0 0 0 0 0 0 0 0 0 0 lro 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C" a o o o o o o 0 o 0 * 8" MAX. BUT THREE MIDDLE ROWS 5 AGGERED AT 8" MIN 8" ZONE 1 B" MAY BE LESS BASED 5" ZONE 2 ON WIND LOAD. 6" ENDLAP _ ROOF UNDERLAYMENTS PER NOA. a w 0 En 0- 4" o O O O O O O o 0 o 0 0 0 o 0 0 0 0 0 0 O 0 0 0 0 0 0 0 n �µ�nfzarnlrzl O O O O O O O O O O O O O O 0 �1�;e pDAM? rzJr✓srr O O O O O O O O O O O O O O O ;�� "� \C EIV O O O O O O O O O O O O O - �� °l 020 r O O O O O O O O O O O O O11 00E i� z -0 TAT - 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 o a 0 o O o C 0 0 0 * 4" 4" MAX. BUT FOUR MIDDLE ROWS STAGGERED AT°4" /M� O'",,�,AL„;�.;1''*� 4" ZONE 3 MAY BE LESS BASED ON WIND LOAD. 3/28/2019 CERTAINTEED CORP, TGFU.R11656 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R11656 1/42 3/28/2019 CERTAINTEED CORP, TGFU.R11656 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R11656 2/42 3/28/2019 CERTAINTEED CORP, TGFU.R11656 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R11656 3/42 3/28/2019 CERTAINTEED CORP, TGFU.R11656 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R11656 4/42 3/28/2019 CERTAINTEED CORP, TGFU.R11656 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R11656 5/42 3/28/2019 CERTAINTEED CORP, TGFU.R11656 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R11656 21/42 3/28/2019 CERTAINTEED CORP, TGFU.R11656 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R11656 31/42 3/28/2019 CERTAINTEED CORP, TGFU.R11656 - UL Product Spec productspec.ul.com/document.php?id=TGFU.R11656 42/42 • `�",•'• �: MIAMI-DADS COUNTY PRODUCT CONTROL SECTION 11805 5W 26 Street, Room 208 DEPARTMENT QF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND C9DE ADMINISTRATION DIVISION T (786)315-2590 F (786) 31525-99 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eav/economv CertainTeed Corporation 20 Moores Road Malvern, PA 19355 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: CertainTeed Modified Bitumen Roofing Systems over Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 17-1003.04 and consists of pages 1 through 49. The submitted documentation was reviewed by Alex Tigera. NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 1 of 49 ROOFING SYSTEM APPROVAL Cate2ory• Roofing Sub -Category: Modified Bitumen Material: APP/SB S Deck Type: Wood Maximum Design Pressure: -127.5 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description All Weather/Empire Base 39 3/8" x 65'10"; ASTM D 4601, Type Asphalt coated, fiberglass reinforced Sheet Roll weight: 70 lbs. II base sheet. (2 squares) Flexiglas Base Sheet 39 3/s" x 98'9"; Roll ASTM D 4601, Type Modified Bitumen coated fiberglass weight: 90 lbs. II base sheet. (3 squares) Flintlastic Base 20 39 3/8" x 49' 6"; Roll ASTM D 6163, Modified Bitumen coated fiberglass weight: 90 lbs. Grade S, Type I base sheet. (1.5 squares) Flintglas Ply 4 39 3/8" x 1647'; Roll ASTM D 2178, Type Fiberglass, asphalt impregnated ply sheet. weight: 38 lbs. IV (5 squares) UL Type G1 Flintglas Premium Ply 6 39 3/8" x 1647'; Roll ASTM D 2178, Type Fiberglass, asphalt impregnated ply weight: 40lbs. VI sheet. (5 squares) UL Type G1 Flintlastic STA 39 3/8" x 32' 10' ; Roll ASTM D 6222, Smooth surfaced APP Modified weight: 871bs. Grade S, Type I Bitumen membrane with non -woven (1 square) polyester mat reinforcement for torch application. Flintlastic GTA 39 3/8" x 32' 10"; Roll ASTM D 6222, Granule surfaced APP Modified weight: 105 lbs. Grade G, Type I Bitumen membrane with non -woven (1 square) polyester mat reinforcement for torch application. Flintlastic GTA-FR 39 3/8" x 32' 10"; Roll ASTM D 6222, Granule surfaced APP Modified weight: 105 lbs. Grade G, Type I Bitumen membrane with non -woven (1 square) polyester mat reinforcement for torch application. Flintlastic GMS 39 3/8" x 32' 10"; Roll ASTM D 6164, Granule surfaced SBS Modified weight: 94 lbs. Grade G, Type I Bitumen membrane with non -woven (1 square) polyester mat reinforcement for mop application. 11•DADE COUNTY NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 2 of 49 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product Flintlastic FR-P Flintlastic Premium FR-P Flintlastic FR Dual Cap Dimensions 39 3/8" x 32' 10"; Roll weight: 101 lbs. (1 square) 39 3/8" x 32' 10"; Roll weight: 101 lbs. (1 square) 39 3/8" x 32' 10"; Roll weight: 103 lbs. (1 square) Flintlastic Cap 30 39 3/8" x 32' 10"; Roll weight: 86 lbs. (1 square) Flintlastic FR Cap 30 39 3/8" x 32' 10"; Roll weight: 86 lbs. (1 square) Flintlastic FR Cap 30 T 39-3/8" x 32' 10"; Roll weight: 100 lbs. (1 square) Flintlastic Base 20 T 39-3/8" x 33'; Roll Weight: 81 lbs. (1 square) Flintlastic Ultra Poly SMS 39 3/8" x 32' 10"; Roll Base Sheet weight: 90 lbs. (1 squares) Glasbase Base Sheet , 36" x 98' 9' ; Roll ""f weight: 75 lbs. (3 squares) Flintlastic Poly SMS Base 39 3/8" x 64' 3"; Roll Sheet weight: 90 lbs. (2 squares) Test Product Specification Description ASTM D 6164, Fire resistant, granule surfaced SBS Grade G, Type I Modified Bitumen Membrane with non -woven polyester mat reinforcement for mop application. ASTM D 6164, Fire resistant, granule surfaced SBS Grade G, Type 11 Modified Bitumen Membrane with non -woven polyester mat reinforcement for mop application. ASTM D 6162, Granule surfaced SBS modified Grade G, Type II bitumen membrane with a nonwoven polyester/fiberglass composite mat reinforcement for use in cold or mop applications. ASTM D 6163, Granule surfaced SBS Modified Grade G, Type I Bitumen membrane with fiberglass mat reinforcement for mop applications. ASTM D 6163, Fire resistant, granule surfaced SBS Grade G, Type I Modified Bitumen membrane with fiberglass mat reinforcement for mop applications. ASTM D 6163, Granule surfaced SBS Modified Grade G, Type I Bitumen membrane with fiberglass mat reinforcement for torch application. ASTM D 6163, Modified Bitumen, coated fiberglass Grade S, Type I base sheet for torch application. ASTM D 6164, Smooth surfaced SBS Modified Grade S, Type I Bitumen Membrane with non -woven polyester mat reinforcement for mop or torched applications. ASTM D 4601, Type Asphalt coated, fiberglass base sheet. II ASTM D 4601, Modified Bitumen coated polyester Grade S, Type II base sheet. NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 3 of 49 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Yosemite Venting Base Sheet 39 3/8" x 32' 10"; Roll ASTM D 3909 Mineral Surfaced fiberglass reinforced weight: 85 lbs. ASTM D 4897, Type buffer sheet. (1 square) II UL Type G3 Flintlastic APP Base T 39 3/8" x 65' 4"; Roll ASTM D 6509 Modified Bitumen coated fiberglass weight: 100 lbs. base sheet. (2 squares) Flintlastic Ultra Glass SA 39 3/8" x 33' 11"; Roll ASTM D 1970 Self -adhering, fiberglass reinforced, weight: 73 lbs. SBS modified bitumen base/ply sheet. (1 square) Black DiamondTM Base Sheet 36" x 687'; Roll ASTM D 1970 Self -adhering fiberglass reinforced weight: 78 lbs. ASTM D4601 Type I modified bitumen base sheet (2 squares) Flintlastic SA P1yBase 39 3/8" x 66'6"; Roll ASTM D 4601, Self -adhering, fiberglass reinforced, weight: 861bs. Grade S, Type II 1 SBS modified bitumen base/ply sheet. (2 squares) ASTM D 1970 Flintlastic SA Mid Ply 39 3/8" x 32' 1 "; ASTM D 6163, Self -adhering, polyester reinforced, Roll weight: 621bs. Grade S, Type I SBS modified bitumen ply sheet. (1 square) FlintBond Brush 5 gallon pails ASTM D 3019 Cold applied, SBS polymer modified asphalt adhesive. NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 4 of 49 APPROVED INSULATIONS: Product Name F1intBoard ISO F1intBoardx ISO FlintBoard ISO Cold ACFoam-II ACFoam-III DensDeck DensDeck Prime TABLE 2 Product Description Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Water resistant gypsum board Water resistant gypsum board H-Shield Polyisocyanurate foam insulation ENRGY 3 Polyisocyanurate foam insulation ENRGY 3 25 PSI Polyisocyanurate foam insulation Multi -Max FA-3 Polyisocyanurate foam insulation SECUROCK Gypsum -Fiber Roof Board homogenous fiber reinforced Structodek High Density Fiberboard High Density Wood Fiber Insulation Roof Insulation board FescoBoard IIAMI•DMA DE COUNTY Expanded perlite and fiber insulation Manufacturer (With Current NOA) CertainTeed Corp. CertainTeed Corp. CertainTeed Corp. Atlas Roofing Corp. Atlas Roofing Corp. Georgia Pacific Gypsum LLC Georgia Pacific Gypsum LLC Hunter Panels LLC Johns Manville Corp. Johns Manville Corp. RMax Operating, LLC USG Corp. Blue Ridge Fiberboard, Inc. Johns Manville Corp. NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 5 of 49 APPROVED FASTENERS/ADHESIVES: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. Trufast #12 DP Fastener Insulation fastener for wood various Altenloh, Brinch & Co. U.S., and steel decks Inc. 2. Trufast 3" Metal Galvalume steel plate 3" round Altenloh, Brinch & Co. U.S., Insulation Plate Inc. 3. FlintFast 412 Coated, carbon steel screw various CertainTeed Corp. 4. FlintFast 3" Insulation Galvalume AZ50 steel plate 3" round CertainTeed Corp. Plate S. FlintFast #14 Insulation fastener for wood various CertainTeed Corp. and steel decks 6. Simplex MAXX Cap Polymer fastner 1" long Simplex Nails, Inc. 7. #12 Standard Roofgrip Insulation fastener for wood various OMG, Inc. and steel. 8. OMG 3" Galvalume Steel Galvalume stress plate 3" round OMG, Inc. Plate 9. Trufast #14 HD Fastener Insulation fastener for wood various Altenloh, Brinch & Co. U.S., and steel decks Inc. 10. OMG Heavy Duty Insulation and membrane Various OMG, Inc. fastener 11. 3 in. Round Metal Plate Galvalume AZ50 steel plate 3" round OMG, Inc. 12. AccuTrac Hextra Carbon steel fastener Various OMG, Inc. 13. AccuTrac Plate Galvalume stress plate. 3" square OMG, Inc. 14. AccuTrac Flat Bottom A2-SS aluminized steel plate 3" square OMG, Inc. Plate 15. Millennium One Step Polyurethane two component 1.5 liters H.B. Fuller Company Foamable Adhesive high rise insulation adhesive 16. Millennium One Step Polyurethane two component LS liters H.B. Fuller Company Green Foamable Adhesive high rise insulation adhesive 17. Millennium PG-1 Low Polyurethane two component 1.5 liters H.B. Fuller Company Viscosity Insulation low rise insulation adhesive Adhesive 18. Insta Stik Quik Set Polyurethane one component It is supplied The Dow Chemical Company Insulation moisture curing adhesive in pressurized cylinders with a net weight of 23 lbs., with a total unit weight of 30 lbs. NOA No.: 18-1127.18 MIAMI•DADE COUNTY Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 6 of 49 APPROVED FASTENERS/ADHESIVES: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 19. OMG OlyBond 500 Spray polyurethane foam 10 gal. bag -in- OMG, Inc. Adhesive insulation adhesive box set and 1.5 liters SpotShot cartridge 20. OMG OlyBond 500 Green Spray polyurethane foam 10 gal. bag -in- OMG, Inc. Adhesive insulation adhesive box set and 1.5 liters SpotShot cartridge APPROVED SURFACING/COATING OPTIONS: TABLE 4 Chosen components must be applied according to manufacturer's application instructions. Any coating, listed below, used as a surfacing, must be listed within a current NOA. System Number Manufacturer Application 1. Generic Gravel applied at 4001bs/sq., adhered with flood coat of asphalt at 601bs/sq. 2. Generic Slag applied at 300 lbs/sq., adhered with flood coat of asphalt at 60 lbs/sq. 3. Karnak Corp. Karnak (#97 AF) Fibrated Aluminum Roof Coating applied at an application rate of 1.5 gal/sq. 4. CertainTeed Corp. FlintCoat A-150 applied at an application rate of 1.5 gal/sq. 5. Gardner Asphalt Corp. APOC #212 Fibered Aluminum Roof Coating applied at an application rate of 1.5 gal/sq. 6. Gardner Asphalt Corp. APOC #400 Sunbrite applied at an application rate of 3 gal./sq. NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 7 of 49 EVIDENCE SUBMITTED: Test A cne !Identifier Name Report Date Factory Mutual Research Corp. FM 4470 3Y8ALAM 03/23/96 FM 4470 OD3A3.AM 04/04/97 FM 4470 1D7A4.AM 11/09/98 FM 4470 2DOAO.AM 12/23/98 FM 4470 3024311 11/01/06 FM 4470 3031350 09/27/07 FM 4470 3036182 07/31/09 FM 4470 3039046 06/15/10 FM 4470 3048520 09/19/13 Underwriters Laboratories, Inc. UL 790 R11656 01/11/13 United States Testing Company ASTM D 5147 97-457-2R 12/02/87 ASTM D 5147 97-457-4 06/03/88 Momentum Technologies, Inc. ASTM D 6164 AX31G8F 06/05/09 TrinitylERD TAS 114 (J) 3507.08.99-1 04/18/01 TAS 114 (J) 3504.06.01-1 06/05/01 TAS 114 3521.07.04 07/29/04 TAS 114 3533.01.06 01/06/06 TAS 114 (H) Letter 04/05/06 TAS 117 (B) 3503.10.06 10/10/06 TAS 117 (B) 06490.04.07-R1 06/27/07 TAS 117 (B) / ASTM D 6862 C8500SC.11.07 11/30/07 FM 4470, TAS 114, FM 4470, C8370.08.08-R1 10/05/09 TAS 114 (J) TAS 114 (H), TAS 117 (B), TAS C30560.06.10 06/10/10 114 (J) FM 4470, TAS 114 C32830.07.10 07/20/10 ASTM D 6164 / D 4798 C31410.01.11-2 01/10/11 TAS 117 B C35500.02.11 02/09/11 FM 4470 (K) / TAS 114 (J) 03515.07.03-1-R1 06/27/12 ASTM D 1876, TAS 1 l4 (H), C42110.08.12 08/13/12 TAS 117 (B) FM 4474 / TAS 114 C39670.08.12 08/20/12 ASTM D 4601 C40050.09.12-1 09/28/12 ASTM D 1970 C40050.09.12-2 09/28/12 ASTM D 5147 / D 4798 C31410.10.10-R1 11/01/12 ASTM D 5147 / D 4798 C31410.01.11-1-RI 11/01/12 ASTM D 4798 C31410.01.11-2A-R1 02/21/13 ASTM D 4798 C31410.12.13 12/05/13 ASTM D 6222 C40050.12.13-R1 12/31/13 TAS 117, TAS 114 C30310.12.09-R1 03/07/14 ASTM D 2178 C47250.03.14 03/26/14 ASTM D 1876, TAS 114 (H), C45620.03.14 03/27/14 FM 4474 NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: O1/17/19 Page 8 of 49 EVIDENCE SUBMITTED: Test Agency/Identifier Name Report Date ASTM D4601 CTR-SC8740.04.15-R2 04/21/15 ASTM D 1876, TAS 114 (H), C47320.03.14-R1 04/01/15 FM 4474 ASTM D 1876 C35460.05.11-R1 05/20/15 FM 4474 (D) / UL 1897 / TAS CTR-SC10420.01.16 01/25/16 114 (J) FM 4474 / TAS 114 (J) CTR-SC9175.09.16-2 09/06/16 FM 4470 (K) / UL 1897 / TAS CTR-SC11590.08.16- 09/06/16 114 (J) R1 ASTM D 4601-04 (2012), Type II CTR-SC11145.09.16- 09/19/16 3C ASTM D 4601-04 (2012), Type II CTR-SC11145.09.16- 09/19/16 3A ASTM D 6163 CTR-SC11145.09.16- 09/19/16 5A ASTM D 6222 CTR-SC11145.09.16- 09/19/16 7A PRI Construction Materials ASTM D 6163 CTC-056-02-01 08/25/10 Technologies LLC ASTM D 6163 CTC-066-02-01 08/09/11 ASTM D 6222 CTC-071-02-01 08/08/11 ASTM D 6164 / D 4798 CTC-093-02-01 08/09/11 ASTM D 4601 CTC-126-02-01 03/12/12 ASTM D 2178 CTC-123-02-01 03/13/12 ASTM D 4601 CTC-127-02-01 03/13/12 ASTM D 6163 CTC-128-02-01 06/11/12 ASTM D 6163 CTC-129-02-01 06/11/12 ASTM D 6164 CTC-132-02-01 06/11/12 ASTM D 6164 CTC-161-02-01 05/09/13 ASTM D 6162 CTC-183-02-01 10/02/13 ASTM D 6164 CTC-190-02-01 12/02/13 ASTM D 1970 CTC-199-02-01 01/22/14 ASTM D 6163 CTC 319-02-01 08/22/17 NOA No.: 18-1127.18 MI F-JJ®uNr�r Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 9 of 49 Membrane Type: APP Modified beck Type 1: Wood, Non -Insulated j Deck Description: 19/32" or greater plywood or wood plank attached with 8d ring shank nails spaced 6" o.c. at I wood joists spaced maximum 24" o.c. System Type E(3): Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet or Flintglas Premium Ply 6 mechanically attached as detailed below. Fastening #1: Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c. Ply Sheet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase (Optional) Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or one or more plies of Flintglas Ply 4 or Flintglas Premium Ply 6 adhered to the base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic STA or Flintlastic APP Base T torch adhere—cr.— Membrane: Flintlastic GTA or Flintlastic GTA-FR torch adhered to base or ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -52.5 psf. (See General Limitation 47) Pressure: NOA No.: 18-1127.18 CMIAMI.DADECOUNTY Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 27 of 49 WOOD DECK SYSTEM LIMITATIONS: A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x T maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchorlbase sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 18-1127.18 Expiration Date: 06/19/23 Approval Date: 01/17/19 Page 49 of 49