Loading...
HomeMy WebLinkAboutCurrent - FL20378_R1_II_FL 20378.2 Extreme Metal Fabricators_ 26GA NAIL STRIP 1.0Product Report Manufacturer: Extreme Metal Fabricators, LLC. 2160 SW Poma Drive Palm City, FL 34990 772 872-8034 Compliant with Florida Building Code 2017 (6th ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications Product: 1" Nailstrip 26GA Steel Standing Seam Roof Panel FBC Sec. 1507.4.2 Yield strength: 40ksi: Attached to Wood Deck with screws. 16" Coverage Corrosion Resistant Compliant: FBC Sec. 1507.4.3 Fastener for Method 1 Attachment # 10 x 1" Pancake Head wood screw to penetrate 3/16" thru 15/32" min. plywood deck Seam Adhesive: Bostik Chem Chalk 915, one component, polyurethane adhesive along male flange the full length of panel. Underlayment: To be compliant with FBC Sec. 1507 Slope: Shall be in compliance with FBC Sec. 1507. 1.1 Install Details: Table A Allowable Loads METHOD 1 main field METHOD 2 perimeter DESIGN PRESSURE* -69.25 PSF -121.75 PSF FASTENER SPACING-ALONG ROWS 6" o.c.6" o.c. FASTENER SIZE: #10 #10 ADHEISIVE: NOT REQUIRED 3/8" BEAD (refer to install details) Certificate of Independence: Locke Bowden, P.E. does not have, not will acquire a financial interest h�\ilf\t'!o\tifitlny,manufacturing or distributing products under this evaluation. , '·'� Q. BOW, i 11•',, ,, ,l ,.,. " • • t " . . l, �.Locke Bowden, P.E. is not owned, operated, or controlled by any ��an�i''ta.'l!!�c."tw er, �distributing products under this '� ' ... - � report. ��'-' � _-· �� 7�:A ·.,��!: ,. v, 'J 9r7>/, •. �pV� � • "),( • p' � -l· " • .. -, �-•. ..-·· Or .t:;; 7;7 ,:,--O o ';J1 1 C:. 9�-"': r ')':> • 0 •c� • a,;., 0, • ,, FLO .\ , � cu :�,-,.,,. 'J'� ..• :, , .... <� -� ..;-· 11, � ') ..i ION P.. \.. �,-:,.., f(:1::1!: \,\\\\ Reference Data: HURRICANE TEST LABORATORY, L.L.C. #TST ID: 1527 Report #:0223-0313-02 TAS125-03(UL 580-06/UL 1897-041) Report#: 0223-1015-06 TAS125-03(UL 580-06/UL 1897-041) EQUIVALENCY: UL 1897-04 IS EQUIVALENT TO UL 1897-12 TEST STANDARD * DESIGN PRESSURE MARGIN OF SAFETY 2:1 FL 20378.2 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details Limitations: 1.Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed.. 2.Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer’s installation reference. 3.Products are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D 4.Engineering analysis for “project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5.Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6.Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7.This report does not imply warranty, installation, recommended product use outside of this report.