HomeMy WebLinkAboutProduct Approval Florida Building Code Online https:j/www.floridabuilding.org/pr/pr_app_Ist.aspx
uu p I Ef/' I 7 `jr
X-1 � F���rr � � �!
ti
"0 �� � d"'^ fix. "5° sr•Y'_ �t 5 r 'F�"T aix- s�
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stals&Facts Publications Contact Us BCIS Site Map Links Search
io!iiia .
Product Approval
l," I oo USER:Public User
le , REaj
Product Approval Menu>Product or Apphc abun Search>Application List
MA
Search Criteria Refine Search
ST. Lucie
Code Version 2017 FL# 14095.1
Application Type ALL Product Manufacturer ALL
Category ALL Subcategory ALL
Application Status ALL Compliance Method ALL
Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL
Product Model, Number or Name ALL Product Description �q�q�grrraaa��� % ALL
Approved for use in HVHZ ALL Approved for use outside H ' ALL
Impact Resistant ALL Design Pressure ALL
Other ALL
Search Results-Applications
FL# Type Manufacturer Validated By Status
FL14095- Revision JELD-WEN National Accreditation&Management Approved
R10 FL#:FL14095.1 Institute
History Model:Premium Atlantic Vinyl (804)684-5124
Description:Single Hung(8100)36"x 72"Insulated Glass(5/16 in PVB or SGP
Lam-1/8 out Annealed)
Category:Windows
Subcategory:Single Hung
'Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your a-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the
office by phone or by traditional mail.If you have any questions.please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1.2012,licensees licensed under Chapter
455.F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If
1 of 2 3/24/20, 09:50
Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEV...
J
V
0�r
SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search
b
��°� Product Approval�ux
USER:Public User
Product Approval Menu>Product or Apuhcaunn Search>Aouhcauon Ust>Application Detail
FL# FL14095-R10
_.__....,.,. __.J" Application Type Revision
Code Version 2017
Application Status Approved
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the
Commission if necessary.
Comments
Archived
Product Manufacturer JELD-WEN
Address/Phone/Email 3737 Lakeport Blvd
Klamath Falls, OR 97601
(800)535-3936
fbcl@jeld-wen.com
Authorized Signature Rylee Sumner Fricks
fbcl@jeld-wen.com
Technical Representative JELD-WEN Corporate Customer Service
Address/Phone/Email 3737 Lakeport Blvd.
Klamath Falls, OR 97601
(800)535-3936
customerserviceagents@jeld-wen.com
Quality Assurance Representative
Address/Phone/Email
1 of 4 3/24/20, 09:51
Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEV...
Category Windows
Subcategory Single Hung
Compliance Method Certification Mark or Listing
Certification Agency National Accreditation&Management Institute
Validated By National Accreditation&Management Institute
Referenced Standard and Year(of Standard) Standard Year
TAS 201 1994
TAS 202 1994
TAS 203 1994
Equivalence of Product Standards
Certified By
Product Approval Method Method 1 Option A
Date Submitted 07/11/2017
Date Validated 07/26/2017
Date Pending FBC Approval
Date Approved 07/28/2017
Summary of Products
F Model,Number or Name Description
14095.1 Premium Atlantic Vinyl Single Hung(8100)36"x 72"Insulated Glass(5/16 in PVB or SGP Lam-1/8 out Annealed)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL14095 R10 C CAC N1011567.04-133.0f
pproved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 04/30/2025
Design Pressure:+65/-70 Installation Instructions
2 of 4 3/24/20, 09:51
Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEV...
Other: Laminated glazing interlayer material requirements meet the FL14095 R10 11 FL14095 R5 II DP65-70 36x72 Impact Installation Instructions.pclf
current edition of the FBC in accordance with Miami-Dade NOA for 1`114095 R10 11 N1011567.04-R3 Dwgs 07252017.1)df
DuPont SentryGlas and DuPont PVB interlayers.White PVC Verified By:Hermes Norero, PE 73778
exterior extrusion meet the current edition of the FBC in accordance Created by Independent Third Party:Yes
with Miami-Dade NOA for Quanex. IG back bedded with Dow 995. Evaluation Reports
Safety glazing required to the exterior at heights above 30 feet. FL14095 R10 AE PER3094.pdf
Created by Independent Third Party:Yes
14095.2 Premium Atlantic Vinyl Single Hung(8100)36"x 72"Insulated Glass(1/8 in-1/8 out Annealed)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: Yes FL14095 R10 C CAC N1011567.08-R1.pdf
Approved for use outside HVHZ:Yes FL14095 R10 C CAC N1011567.09-R2.pdf
Impact Resistant: No Quality Assurance Contract Expiration Date
Design Pressure:+65/-70 04/30/2025
Other:White PVC exterior extrusion meet the current edition of the Installation Instructions
FBC in accordance with Miami-Dade NOA for Quanex. IG back FL14095 R10 II N1011567.09-R2 Dwns 07252017.pdf
bedded with Dow 995.Safety glazing required to the exterior at FL14095 R10 11 PAV TSH FBC 36x72 SS 2017-06-26.pclf
heights above 30 feet. Verified By:Hermes Norero, PE 73778
Created by Independent Third Party:Yes
Evaluation Reports
FL14095 R10 AE PER4869 SS 2017-06-26.pdf
Created by Independent Third Party:Yes
14095.3 Premium Atlantic Vinyl Single Hung(8100)52 1/8"x 75"Insulated Glass(3/16 in-3/16 out Annealed)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL14095 R10 C CAC N1011567.06-R1.pcif
Approved for use outside HVHZ:Yes FL14095 R10 C CAC N1011567.07-R2.pdf
Impact Resistant: No Quality Assurance Contract Expiration Date
Design Pressure:+65/-70 04/30/2025
Other:White PVC exterior extrusion meet the current edition of the Installation Instructions
FBC in accordance with Miami-Dade NOA for Quanex. IG back FL14095 R10 II N1011567.07-R2 Dwgs 07252017.pdf
bedded with Dow 995.Windows with insulated glass wider than 36" FL14095 R10 II PAV TSH FBC 52x75 SS 2017-06-26.pdf
require setting blocks.Safety glazing required to the exterior at Verified By:Hermes Norero, PE 73778
heights above 30 feet. Created by Independent Third Party:Yes
Evaluation Reports
FL14095 R10 AE PER4870 SS 2017-06-26.1)df
Created by Independent Third Party:Yes
14095.4 Premium Atlantic Vinyl Single Hung(8100)52 1/8"x 75"Insulated Glass(5/16 in PVB or SGP Lam-1/8 out
Annealed)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: Yes FL14095 R10 C CAC N1011567.02-R2.pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 04/30/2025
Design Pressure:+50/-60 Installation Instructions
Other:Laminated glazing interlayer material requirements meet FL14095 R10 11 FL14095 R5 11 DP50-60 52.125x75 Impact Installation Instructions.pdf
the current edition of the FBC in accordance with Miami-Dade NOA FL14095 R10 11 N1011567.02-R2 Dwgs 07252017.pdf
for DuPont SentryGlas and DuPont PVB interlayers.White PVC Verified By:Hermes Norero, PE 73778
3 of 4 3/24/20, 09:51
NOTICE OF PRODUCT CERTIFICATION
�10
fiGtlq
cER rlFiCn r10N N0: NIo11567.04-R3
> � DATE: 05/23/2013
. N CERTIFICATION PROGRAM: Structural
y�
COIN NY: JELD-EVEN
"ear.c,:� CODE: 1822-1
� REVISION DA'L'E: 01/13/2017
To veri fy that[lie"Notice of PCodUCI Certification-is valid.please visit wwty.NAi%I lCertif ication.com to assure that the
product isactivcand currenth listed.Thiscertificationrepresentsproducteonf'ormitytothe applicablespecificalionand
chat certilir.»ioneriteria has been satislicd.ANA MI approved ccnif ication label must be applied to the product to claim
certification status. Please review and advise NANII if any corrections are required to this document.
COMPANY NAME AND ADDRESS PRODUCTDESCRIPTION
JELD-EVEN "Premium Atlantic Vinyl Sin;le Hung(81(1(1)"
3737 Lakeport Boulevard Impact Rated Vinyl Single Hung Window
Klamath Falls,OR 97601 (Fin or Flange Installation)
Configunuion:O)N
Glaring:IG-1%S"Annealed Glass'Laminate-
1/8"Annealed Glas,10.090"I'VB Interlayer by DuPonv
lib"Annealed Ulass or IG-1:S"Annealed Glass'Lamwatc-
U8":uatealedGlass%0.090"SentrvGlas Plus by Ihd'omV
US"Annealed Glas,
Frame: %V-9141nm(36") 1-1-1829mm(72")
Sash: W-R45mm(33 25") 11-883nun(34.75")
SPECIFICATION PRODUCT RATING
TAS 201/202/203-94 Desitin Pressure: +65/-70 psf
Large Missile Impact Rated
Product Tested Lav: national Certified Testing Laboratories
Report No: NCTL-'_]0-3875-1
Expiration Date: ApHl 30,2025
Administrator's Siunature:
NATIONAL ACCREDITATION AND
MANAGEMENTINSTITUTE, INC.
4794 George Washington Memorial Highway
Haves,VA 23072
Tel: (804)684-5124
Fax: (804)684-5122
NAIL PIN INSTALLATION
111411111,
II
—7
Ci A,'r.46 LIE T1:l
F4AAlE ti. JAMB SECTION(TYP)
11-01"12f5117 HORIZONTAL SECTION
f
PREMIUM ATLANTIC VINYL SH WINDOW
01 2 Max Frame I DP RATINGJIMPACT
Irm o.- 65/-70 YES
LARGE MISSILE IMPACT
Installation Notes: General Notes:
1Seal flangeiframe to substrate. I The product shown herein is designed,tested and manufactured to comply with the wind load vitoda
2 Use:10 PH or greater fastener though the nail fin with sufficient length to penetrate a rninirrunn of I of Vie adopted International Building Code(!BC).the International Residential Code(IRC),the Flonfla
11T into the wood frairung.For 2X wood(Tame substrate(min.S G.=0.421. Building Code(FBC)including HVHZ and the industry requirement for the stated conditions.
3. Host structure(wood buck.masonry,steel)to be designed and anchored to properly transfer all loads 2 Al glazing shall conform to ASTM E1300,
o the structure. Tile host structure is Vie responsibility of[tie architect or engineer of record for Vie 3 At mirimurv,glazing is 3mrn annealed-1 imin airspace-3mm annealed-2(tim PVB Interlayer by
project of installation. DuPont 3mrn annealed.
Digitally signed by Hermes F.
Norero.P.E. lUse structural or composite shims where required
lull
Reason:I approving this document
Ddte:2014.09.19 16:26:14-04'00'
This srhajule addresses only the fasteners,requued to ancnor the
x5ndow to armeve the rated design pressureupto the size limitations 0%
noted.his not intended as a guide to the installation process and does Or'
1.0A"11111H,
[lot address tie rualing consideration that may arise in different wall .1737 Lakeport Blvd
08/13/20LI41 Klamath Falls,OR.97601
• �.r JELRWEN ,
cotAtions For the complete insfaValion procedure.see the instructions NF. -
.. 0 rp,,P"
I. D.Vvzo NTS Phone. (5-11)@92.3451
pacUVdwilh the•window or go to 7f
w,mvieki-wen comiresourctislinslafation,
I Kantola
-o 11—ST Premium Atlantic Vinyl Impact Single Hung Window
/ATE OF .: X
-)ISCLAINIER. I / - 44,
This drawing and its contents are confidential and are rot to be 0
2
,eproduced or copied inwride or in part or used or disclosed b others M
qxrept as authorized by JELD-WEN Inc. salt.338 5. -D IN All'. 1"' 00 1--
_F
M. ,ASN NCTL210-387
%1ASONRY INSTALLATION
0,
7"
T
MfF
OF
Hc41ZtiTAL SEC70N
PREMIUM ATLANTIC VINYL 5H WINDOW
r Max Frame DP 1—� Ov -65/-70 ! YES
11T
PICAL ELEVAT`10Ny/F*TH FA5-,-tNEA5PAr.t*
LARGE MISSILE IMPACT
Installation Notes; General Notes: hereir is designed; r w:th thevindload criteria
1 Seal flange frame to substrate I The product shown, . .ed,�ested,,indminufacturediolt).,;�ly 1
2. Use 3116'ITw Topcon or equivalent fasteners through frarric,with sufficieril!ength to penetrate a of the adopted International Building Codo(IBC!,.he International Residential Code!IRC)Ahe Florida
minimum of 1 114'into concrete or masonry at each location with a 2 112'rein from edge distance.For Building Code(FBC)including H1jHZand,he industry�feq,.,IremanIfcr the stated conditions.
concrete (min rc=3000psi)or masonry substrate l9,dU shall adhere to ASTM C90). 2 All glazing shall conform to ASTI,4 El NO.
3 Host structure nvood buck,masonry,steel)to be designed and anchored to property transfer all leads 3 At nummum,glazing is 3mrn annealed-11 min airspace-3mm annealed-2111in PVB Interlayer by
to the structure The Nov structure is the responsibility of the tinctnarttorengineer oi record for the DuPont-3mrn annealed,
project of Installation. 4. Use structural or composite shims where required.
This schoeule addresses only thotasleres mquiredioanchor Ine
v,Mmv In achieve the rated des,gn pressure up lou'le size limitations —0—
noted.It is not intended as a guide to installation process and does
not address he sealing considelabon that may arise in different will 3737 Lakeport Blvd
08/13/2014
conditions For the complete installation procedure seethe instructions JELDVENKIamakh Falls,OR.97601
,-go — -� Z
n D�Vezo NTS Phone: (541)882-3451
packaged,mlh the wjndc-,v or go mo
I
7337
vivvw jr.ld-Ln I Kantola
WWATiL 0 Premium Atlantic Vinyl Impact Single Hung Window
'ISCLAIIJER. -P *- , , .1 1
This drawing and its contents are confideritta.and are roto GeP CIRO'. Uj
eproduced or coptatim whole or in Dart or used or disclosed to cinprs E, t'338 NCTI-2�6
axcept as authorized by JE l7 MEN Inc q
-t -3875-j-� ...... 00
PR "I
STEEL INs,rALIATION
C21
1-2
I i0`1
%A7711r tirTAIL
■ JAMB SECTION(TYP)
FRAME 5U1*Tr0N TVP) HORIZONTAL SECTION
VEPTECAL 5ICTION
IT/ PREMIUM ATLANTIC VINYL SH WINDOW
Max Frame I[)P RATING!IMPACT
rvPTCAL ELEVA72ONWIM I'ASTENEP 50ACJN> VIA r%-r i LARGE MISSILE IMPACT
Installation Notes: General Notes:
!. Seal fiange,'frarrie to substra:e. ; The product shown heroin is designed,tesed and MinUfaCtiffed to comply voln the svird:oad critena
2. For anchoring into metal framing use 08 TEK Self Tipping GC,'eWG with sufficient lengih to achieve a of theadocited International Baildx.g Coal the International Res;dential Code(IRCI the Florida
nilrinnuill embedment of three threads past the frame tn.�L*ness.Steel substrate min.18ga.,N=33'Kq. Building Code fFBC)including HVHZ and the industry requirement for the stated wnd;[,Ons
3 Host structure(wood buck-masonry,steel)to be designed and anchored to properly transfer all loads 2 Ali g5ozing shalt conform to ASTM E11300
I
!a the structure.The hast structure is the responsibi!iVi of Cie architect or engineer of record for Ine At mirciraum.gazing is 3mm annealed-1 Immairspice-3mm armeafiid-2mrn PV8 Interlayer by
project Of installation. DuPont-3mmannealed.
4 Use structural or composite shims where required,
T,e;scheduJoaddesses only the fasL-Pcrs required to anchor the %V11111111,
window to achieve Me rateddes,qn pressureup to the size limitaws -\0�C F: A, 4.
noted
I"n-
...... 3737 Lal,eport N'vil
08/13/2014
not address re sealing consideTation that m3 arise in different wail
condi!:nns,For Procedure.see ne instructions • JELDVEN Klamath Falls,OR.97601
rackaqed with tiemridoA,or gotori N D.Vezo NTS 11.n, (5411882-3451
ri.conl%esource5riiista!13tion, J.Kantola
DISCLAIMER -09TAATE OF aPremium Atlantic Vinyl Impact Single Hung Window
" 7 1 . ,, .4 41
This drawing and its contents are confidential and are not to be dRO' �4,
o "B66
9,29,
a
,eproducEd or weed tn whole or in pan or used or disclosed!a others pMP.E
3xcepiasauthorized by JELD-WEN Ir.c. 3 E to338 -FBC 700��
(71
N
['11POUGH FRANfE
. -11
I NSTALLATION
1 1
_T 2
Mw
_F Fd2\
JAMB SECTION(-VYP)
GLALINIS biTAIL
HORIZONTAL SECTION
FPAM-5ECTION(r/P
vE�TAL,ECT`10f)
EEL— 2 Ill PREMIUM ATLANTIC VINYL SH WINbOW
Max Frame DIP RATING IMPACT
-1 -]
36.72 -65/-70 YES
LARGE MISSILE IMPACT
Installation Notes: General Notes:
1 Seal flange;*,rarre to substrate I The product shown herein is descncd,tested and manufactured to comply wth the wind load criteria
2. Use 910 PH or greater iastener though the;amb witn sufficent length to penetrate a ntrumum of 1 112' of the actooted Intemationai Bulldog CodelIBC).the International Residential Cede(IRCohe Fonda
into the-.,.,00d framing For 2X wood frame substrate tmm.S.G=0 42). Building Code(FBC)inducing H1VHZ and'he industry requirement for the stated conditions.
Host structure(wood Duck..masonry,slecil)m be designed and anrnored to property trinster ail loads 2. All glazing shall conform to ASTM E1300
lothe structure The host structure is the responsimiltij ol the architector engininrof record for the 3. At miriminn,glazing is Jmm annealed-1 Imm airspace-3mm annealed-2mm PVB lnterlayef by
project ofmstalladon Addd t. Nfm-- DuPont-3mm annealed
III, N1011',ii" ria-a+ 4. Use structural or composite shims where nquirpd.
R-wi,we.A By. t-
Tnis schedule addresses only in,fasteners,equved to anchor'he
window to achieve the later,design pressure up to the size limitations
noted It is not intended as a q,,AdP to-he installation process and does
i'llizTELD3737 Lakeport Blvd
not address he sealing considemuori that may arise in different wall 06130/2015
conditions,For the comploo the in<tn.,tions 'Ir -WEN Klam.)th Falls,OR.1)7601
packaged with tie window or go to D.Vezo NTS Phone: (800)535-3936
cntc�zn,AvrN le4won I` ll
.1.Kancola
DISCLAIMER: PremiumAtlantic Vfnyl Impact Single Hung Window
rhes drawing and its cor(ents are contidenual and are not to be
,eproduced or copied tnwrole or in cartor used or disclosed to others s D
00
ceDtas authorized by JELD-OVEN Inc
I
Ash _FBC
398 E.Dania Beach Blvd.
BUILDING DROPS Suite 338
A Perfect Solution in Every Drop Dania Beach,FL 33004
954.399.8478 PH
Certificate of Authorization:29578 954.744.4738 FX
contact@buildingdrops.com
P.i"od11c . I;�,vl atioll Report
r
of
JELD-WEN, Inc.
Premium Atlantic Vinyl Single Hung - Impact
for
Florida Product Approval
R.eporI No. 309"41
Current Florida Building Code
Method: 1—A(Certificate)
Category: Windows
Sub— Category: Single Hung
Product: Premium Atlantic Vinyl Single Hung-Impact
Material: PVC
Product Dimensions: 36•'x72"(0/X)
Prepared For:
"V7,37 1,11,wporl 13tv��1.
K1,111t:ftll Falk, OR 97001
Prepared by:
Herine, 1". JNorero, P.E. ��`� ES F. O
Florida Professional Engineer#7377£3 �� Q�.• ��
Date:08,111/2014 �0
N 7
Contents_ —
['valuation Report Pages 1 4 :mooT�TE OF Ofw`,
•��i��',0 f0NA i 1��
t11
Hermes F.Norero,P.E.
Florida No.73778
BUILDING DROPS Date: 0 : 30 4
Report NoDate: : 3094
} A Perfect Solution in Every Drop
Certificate of Authorization:29578
Manufacturer: JELD-WEN,Inc.
Product Category: Windows
Product Sub-Category: Single Hung
Compliance Method: State Product Approval Method (1)(a)
Product Name: Premium Atlantic Vinyl Single Hung—Impact
(Impact)
36"x 72"(O/X)
Scope: This is a Product Evaluation Report issued by Hermes F.Norero,P.E.(FL q 73778)for JELD-WEN,Inc.
based on Method la of the State of Florida Product Approval,Department of Business and
Professional Regulation-Florida Building Commission.
Hermes F.Norero,P.E.does not have nor will acquire financial interest in the company
manufacturing or distributing the product or in any other entity involved in the approval process of
the product named herein.
This product has been evaluated for use in locations adhering to the current Florida Building Code.
See Installation Instructions NCTL210-3875-1-FBC,signed and sealed by Hermes F. Norero,P.E.(FL#f
73778)for specific use parameters.
Limits of Use:
1. This product has been evaluated and is in compliance with the current Florida Building Code,
including the"High Velocity Hurricane Zone"(HVHZ).
2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into
substrate material shall be beyond wall dressing or stucco.
3. When used in areas requiring wind borne debris protection this product complies with
Section 1609.1.2 of the current Florida Building Code and does not require an impact
resistant covering.
4. Site conditions that deviate from the details of drawing NCTL210-3875-1-FBC require further
engineering analysis by a licensed engineer or registered architect.
5. See Installation Instructions NCTL210-3875-1-FBC for size and design pressure limitations.
Hermes F.Norero,P.E.
Florida No.73778
Page 2 of 4
BUILDING DROPS Date: 0 : 30 4
Report NoDate: : 3094
ll:} A Perfect Solution in Every Drop
Certificate of Authorization:29578
Quality Assurance: The manufacturer has demonstrated compliance of products in accordance with the
Florida Building Code for manufacturing under a quality assurance program audited
by an approved quality assurance entity through National Accreditation and
Management Institute(FBC Organization#:QUA 1789).
Performance Standards: The product described herein has been tested per:
• TAS 201-94
• TAS 202-94
• TAS 203-94
Referenced Data: 1. Product Testing performed by National Certified Testing Laboratories NW
(FBC Organization#TST9341)
Report 4:NCTL-210-3875-1, Report Date:4/18/2013
2. Certification Agency
National Accreditation and Management Institute
(FBC Organization#:CER 1773)
3. Material Certification
Miami Dade RER—Product Control Section NOA
E.I.DuPont De Nemours&Co.,Inc.:PVB Interlayer
4. Material Certification
Miami Dade RER—Product Control Section NOA
Quanex Building Products:PVC Extrusions
Hermes F.Norero,P.E.
Florida No.73778
Page 3 of 4
BUILDING DROPS Date: 0 : 30 4
Report NoDate: : 3094
n
A Perfect Solution in Every Drop
Certificate of Authorization:29578
Through Frame Installation: 1. Approved anchor types and substrates are as follows:
A. For concrete(Min.f c=3000 psi)or masonry substrate(Min.f'c= 1500 psi)where one
by(1X),non-structural,wood bucking is employed,use(1)3/16"diameter ITW Tapcon
type concrete screw anchors per location of sufficient length to achieve minimum
embedment of 1.25"into concrete or masonry.
B. For concrete(Min.f c=3000 psi) or masonry substrate(Min.f'c=1500 psi)where wood
bucking is NOT employed,use(1)3/16"diameter ITW Tapcon type concrete screw
anchors per location of sufficient length to achieve minimum embedment of 1.25"into
concrete or masonry.
C. For steel substrate,use(1)#8 Tek Screw type steel frame(min.18ga.)anchors per
location of sufficient length to achieve minimum three threads of penetration beyond
steel structure.
Nail Fin Installation(Where applicable):
A. For wood substrates(Min.S.G.=0.42)use(1)#30 Wood Screw type installation anchors
per location of sufficient length to achieve a minimum embedment of 1.50"into the
wood substrate.
Refer to Installation Instructions(NCTL210-3875-1-FBC)for anchor spacing and more details of the
installation requirements.
Design Pressure:
Design Pressure
_ Positive 65 PSF
Negative 1 70 PSF
Hermes F.Norero,P.E.