HomeMy WebLinkAbout05100534 · .\.. .~. '.. "J <Í...: ~ ': ~. ~.;;:1 ..... , ðSM CAPRI ROOFING INSPECTION REPORT Code Administration, Plan Review & Inspection Servic RECEIV OCT 2 0 BY:. ENGINEERING PROJECT: ORDER #: PERMIT #: CLIENT: TYPE OF INSPECTION: Princess Condominiums of Jensen Beach Contractor: RSI of Florida, Inc. 8/25/2006 477481 i1\~S34'¿96S0 S. Ocean Drive, Jensen Beach RSI of Florida In Progress DATE: COMMUNITY: Lot/Block/Bldg. #: PERFORMED BY: NA/NA/NA AI Ca rter INSPECTION PERFORMED: ~~ ~ (1) Flashing - Metal Accessories Inspection ADDITIONAL INFORMATION ON MEMBER/AREA INSPECTED: Crew apply flashing-veral around piping, parapet and drains. DISPOSITION OF INSPECTION: Approved. All Work inspected by CAPRI was in accordance with the approved plans. VERBAL INSTRUCTIONS: NOTES: Investigate/ ca ution. Respectfully submitted, CAPRI Engineering, LLC. Distribution Copy: a 11- · ~ A. Roland Holt, P.E. Regional Vice President STATE OF FLORIDA: Professional Engineer Number: 0050221 Standard Building Inspector: BN-0000197 Bill Logsdon Bill Temple 091308 CAPRI Engillccring LLC 7846 S.\V. Ellipse \Vay .Stuart, Florida 34997 .(772) 286-8340 .Fax: (772) 286-8584 \ V\vw. ca p ri e 11 gi 11 eerill g. con1 6SM C A PR I Code Administration, Plan Review & Inspection Services ENGINEERING ROOFING INSPECTION REPORT wh PROJECT: ORDER #: Princess Condominiums of Jensen Beach 490356 05100534 - 9650 S. Ocean Drive, Jensen Beach RSI of Florida In Progress Contractor: DATE: RSI of Florida, Inc. 9/14/2006 PERMIT #: COMMUNITY: CUENT: TYPE OF INSPECTION: Lot/Block/Bldg. #: PERFORMED BY: NA/NA/NA Daniel Divan INSPECTION PERFORMED: (1) Final Roofing ADDmONAL INFORMATION ON MEMBER/AREA INSPECTED: Unscheduled, in progress inspection electrical-prior to final, all conduits to roof mounted chiller and exhaust fans are to be repaired supported, fastened to unistruct and secured for wind resistance roof jack at exhaust fan next to elevator hoist room not sealed communications. Cabling on the perimeter wall to' be anchored to wall with approved connectors. Roof chiller the "]" box at the chiller has completely fails due to rust. The chiller is leaking such that the constant water on the roof "cap" material. This material is not designed for constant water. Communications cooler is discharging condensate to roof "cap" this "cap" is not designed for constant water. DISPOSmON OF INSPECTION: (All pending and rejected inspections require are-inspection) Rejected VERBAL INSTRUCTIONS: NOTES: Respectfully submitted, CAPRI Engineering, LLC.. Distribution Copy: a' /l~otì A. Roland Holt, P.E. Regional Vice President STATE OF FLORIDA: Professional Engineer Number: 0050221 Standard Building Inspector: BN-0000197 ----. Bill Logsdor1 Bill Temple CAPRI Engineering LLC lQA~ ~ Ul ""11;1''''''''' W"'J' - ~...."'.... ""1^":~1 '1~1'ß" ~ {"'7"} "Q~ Q~~n - ""q"'" {"1"} 1Q~ Q~Q AI www.capriengineering.com