Loading...
HomeMy WebLinkAbout05110353 A.~ A..AS.HTO R' B FIELD DENSITY REPORT Recreational Design & Canst. 3990 N. Powerline Rd. Ft. Lauderdale, FL 33309 PROJECT NO. PSL-l 005 CLIENT Recreational Design & Canst. c.c. TO AT TN: Burt r....'f..··"..fÞ... ~:Y'.~.....;..;o.....,..'....;.... ~~; . fi ~-,. ~ ~ ~ ~' [;' ~ ~}r~ . R.£CEIVED JUL 2 7 2006 BY: PROJECT Lakewood Park CMT LOCATION Lee Road Ft. Pierce REPORT NO. 4 7 NO. OF DENSITIES 3 TESTED BY R. Garcia DATETESTED Jul 14,2006 CONTRACTOR AREA CONSTRUCTION TYPE Pool Bldg. Slab-an-Grade ¡J~~·f~ 0571-035-3 MOISTURE DRY DENSITY DENSITY LOCA TION MA TERIAL TYPE COMPACTION NUMBER FIELD LAB FIELD LAB % 211 @ E. Side Brown 6.9 10.5 111.4 111.0 100 Sand 212 @ w. Side Brown 8.3 10.5 110.2 111.0 99 Sand 213 @ Approx. Center Brown 7.4 10.5 111.5 111.0 101 Sand FIELD METHOD LABORATORY METHOD COMMENTS Nuclear ASTM 02922 Modified Proctor ASTM 01557 SPECIFIED COMPACTION 9 8 ,hOW DENSIT-!,~J:,~N.91C:.4TED * Page 1 of 1 J u 1 1 7 , 2 0 0 6 Nutting Engineers of Florida, Inc. .. . ""'....'. ',~. ...." "": .~~~ :::::.:,..{....i~~~~2:'~k;::,-:·:':'··.4~~ PER 1-' 7(tft~' vidan P.'E., #60223 Reporting of these test results constitutes a testing service only. Engineering interpretation or evaluation of test results is provided only on written request. Palm Beach (561) 736-4900 * Broward (954) 941-8700 * Miami Dade (305) 824-0060 * Port St. Lucie (772) 408-1050 Public Works St. Lucie County, FL St. Lucie County FEB 0 1 2007 Building & Zoning Departme: 2300 Virginia A venue Fort Pierce, FL 34982 772-462- 2165 Fax 772-462-6443 ?crzré f) &3) RECEIVED Request for 30-Day Temporary Power Release Date: 12/20/06 Permit Number: SLC - 0511 - 0353 5990 Emerson Avenue - Ft. Pierce, Fl. 34951 Property ,Address: THE UNDERSIGNED HEREBY REQUEST RELEASE OF ELECTRICAL POWER TO THE ABOVE DESCRmED PROPERTY, FOR A PERIOD NOT TO EXCEED THIRTY (30) DAYS, FOR THE PURPOSE OF TESTING SYSTEMS AND EQUIPMENT IN PREPARATION FOR FINAL INSPECTION. IN CONSIDERATION OF APPROVAL OF THE REQUEST WE HEREBY ACKNOWLEDGE AND AGREE AS FOLLOWS: 1. This temporary power release is requested for the above stated purpose only, and there will be no occupancy of any type, other than that permitted by construction during this time period. 2. As witness by our signatures, we hereby agree to abide by all terms and conditions of this agreement, including Building Division Policy, which is incorporated herein by reference. 3. AU conditions and requirements listed in the attached document entitled ''Requirements for 30 Day Power for Testing" have been fulfilled and the premise is ready for compliance inspection. 4. All requestS for an extension beyond 30 days must be made in writing to the Building Official stating the reason for the request. Power may be removed from the site and/or a Stop Work Order issued if the Final Inspection has not been approved within 30 days. A fee of $100.00 will be required to lift the Stop Work Order. WE HEREBY RELEASE AND AGREE TO HOLD HARMLESS, ST. LUCIE COUNTY, AND THEIR EMPLOYEES FROM ALL LIABILITIES AND CLAIMS OF ANY TYPE OF NATURE WHICH MAY ARISE NOW OR IN THE FUTURE OUT OF THIS TRANSACTION, INCLUDING ANY DAMAGE WHICH MAYBE INCURRED DUE TO THE DISCONNECTION OF ELECTRICAL POWER IN THE EVENT OF VIOLATION OF THIS AGREEMENT. ÐJ DATE /.{' RACTOR SIG,. 'fz " I ELECTRICAL CONTRACTOR SIGNATURE / ¿.-.z g.-o6 DATE St. Lucie County Building and Zoning Department Requirements for 30 Day Power for Testing I. Form entitled "Request for 30-Day Temporary Power Release" must be fully executed and posted in the Building Department record files prior to inspection. II. Inspection Requirements: 1. Address numbers shall be posted per county Ord. No. 7.05.09. 2. All entrances, exits, windows and garage doors must be lockable. 3. All circuits on exterior shall be terminated in a box with weatherproof cover. The same applies to a disconnect. If circuits are at or above 7'6" from grade they may be capped with wire nuts and taped. 4. All breakers must be installed. Any blank pace must be closed b a breaker or approved filler plates. 5. Interior Wiring: All receptacles, light fixtures and fans must be trimmed. Any fixture below 7'6" from the floor or mezzanine that is not available at the time of inspection must have an Invisoplate installed. Fixtures at or above that height may be capped with wire nuts and taped. 6. All smoke detectors must be installed. 7. Kitchen cabinets must be installed; any exception for special conditions or circumstances must have an approval prior to scheduled inspection. 8. Sewer and water connections must be complete. Only well pumps are excluded from this requirement. 9. Exterior construction must be complete and weather tight, including stucco, siding, roof and soffit. 10. Permit work shall be substantially completed except for back orders, paint on exterior, carpet and/or floor covering, pumps, air conditioners and driveway.