Design pressure calcs
NewSouth WIN DOW SOLUTIONS 2526 Okeechobee Blvd, West Palm Beach, FL 33409 • 561-712-9000 • CRC1330622 Property Information ] [ Building Information Owner: Carol & Martin Kahn Wind Zone: 170 MPH. Address: 6019 Travelers Way Exposure Category: C Ft Pierce, FL 34982 Minimum Building Dimension: 25 ft. Mean Roof Height: 15 ft. Risk Category: Il Prepared in accordance milh: ASCE 7-10, Chapler30. Wind Loads - Componenu and Cladding. 6ih Edition (20/7) Florida Building Code. Page 1 of 1 Design Pressure Calculations ening Location Device Device j Device Max PositiveO L ax Negative Number Zone Width (in)Height (in) Elevation (ft) Pressure (psf) Pressure (pst) 1 Int 36 61.75 7 36.7 -39.9 2 Int 36 61.75 7 36.7 -39.9 3 Int 36 61.75 7 36.7 -39.9 4 Int 52 37 7 37.1 -40.3 5 Int 36 55 7 37.0 -40.2 6 Int 36 55 7 37.0 -40.2 7 Int 36 55 7 37.0 -40.2 8 Int 25.50 49.25 7 37.8 -41.0 9 Int 25.50 4.9.25 7 37.8 -41.0 10 Int 25.50 37 7 37.8 -41.0 11 Int 52 55 7 36.1 -39.3 Prepared in accordance milh: ASCE 7-10, Chapler30. Wind Loads - Componenu and Cladding. 6ih Edition (20/7) Florida Building Code. Page 1 of 1