Project infor, wind zone
NewSouth WINDOWSOLUTIONS 2526 Okeechobee Blvd, West Palm Beach, FL 33409 • 561-712-9000 • CRC1330822 Property Information Building Information Owner: Arthur & Patricia Nelson Wind Zone: 170 MPH. Address: 1701 S Brocksmith Rd Exposure Category: C Ft Pierce, FL 34945 Minimum Building Dimension: 25 ft. Mean Roof Height: 25 ft. Risk Category: Il Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Numberr Zone Width (in) Height (in) Elevation (ft) Pressure (psf) Pressure (psf) I Int 72 59.50 7 39.1 -42.7 2 Int 36 35.50 7 42.1 -45.7 3 Int 35.50 35 7 42.1 45.7 4 Int 35.50 35 7 42.1 -45.7 5 Int 72 59.50 7 39.1 -42.7 6 Int 35.50 35 7 42.1 -45.7 7 Int 35.50 35 7 42.1 -45.7 8 Int 35.50 35 7 42.1 -45.7 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads -Component/ and Cladding. 61h Edition (2017) Florida Building Code. Page 1 of 1